Search Results

Search found 7992 results on 320 pages for 'hp power protector'.

Page 86/320 | < Previous Page | 82 83 84 85 86 87 88 89 90 91 92 93  | Next Page >

  • how to init and malloc array to pointer on C

    - by DoronS
    Hi all, looks like a memory leak when i try to initializing an array of pointers, this my code: void initLabelTable(){ register int i; hashNode** hp; labelHashTable = (hashNode**) malloc(HASHSIZE*sizeof(hashNode*)); hp = labelHashTable; for(i=0; i<HASHSIZE; i++) { *(hp+i) = NULL; } } any idea?

    Read the article

  • Is this class + constructor definition pattern overly redundant?

    - by Protector one
    I often come across a pattern similar to this: class Person { public string firstName, lastName; public Person(string firstName, string lastName) { this.firstName = firstName; this.lastName = lastName; } } This feels overly redundant (I imagine typing "firstName" once, instead of thrice could be enough…), but I can't think of a proper alternative. Any ideas? Maybe I just don't know about a certain design pattern I should be using here? Edit - I think I need to elaborate a little. I'm not asking how to make the example code "better", but rather, "shorter". In its current state, all member names appear 3 times (declaration, initialization, constructor arguments), and it feels rather redundant. So I'm wondering if there is a pattern (or semantic sugar) to get (roughly) the same behavior, but with less bloat. I apologize for being unclear initially.

    Read the article

  • Laptop automatic shutdown after 2 seconds

    - by leladax
    I'm trying to insvestigate which component produces this behavior. Other indications show it may be the GPU but I wonder if anyone knows more. It's a Toshiba Satellite X200 description: AC power shows the power being fed normally, when turned on the fan works and it appears to be starting up but after 2 seconds it shuts down with only the 'AC power connected" led on. -- seconds are about up to 4,maybe not 2 exactly.

    Read the article

  • Toshiba A205-5804 freezes when plugged in

    - by heron
    Well I have a Toshiba A205-5804 and the problem is that the screen freezes anytime I plug the pc into the external power supply, not as most of the computers having the same issue, my computer DOES freeze in safe mode, and I really can't bear this problem for much longer... It's not an overheating problem, the computer is not getting hot or anything related, I've already tried changing the AC adapter, booting only with AC and no battery, and also all of these suggestions: Try changing the following setting in the bios setup, under the 'Advanced' tab Dynamic CPU Frequency: Mode = Always Low (NOT DYNAMIC) My laptop has been running on AC power without a problem for 24hours, including many restarts, and when I went back to the original bios setting, the problem returned almost straight away. EDIT Other suggestions I found on the web from here and here: Set the power plan to high performance Set the power plan to "Minimal Power Management" (1 and 2 do conflict) Start - Control Panel - Device Manager -- Processor - disable one of two processors - reboot normally 4.Do this: Only plug battery into laptop Turn on the laptop and start Windows normally Plug AC adapter into laptop, the screen will freeze Leave the laptop the way it is for 12-24 hours After 12-24 hours, turn it off the hard way Once it is turned off, turn it back on. The laptop is working now. I have no idea of what can it be...

    Read the article

  • What's your favorite programmable calculator?

    - by Pat Notz
    The HP-32S still holds a soft spot in my heart, even though it only had 4 registers. I have fond memories of writing a nonlinear solver for finding an azeotrope curve during a Thermodynamics final. Despite the increase in power, memory, pixels and features the HP-32G that followed never could steal my heart away. Here's to you, HP-32S. Let's hear it, what's your favorite programmable calculator? As with all poll type questions, do NOT submit a new answer unless your answer is not represented. Vote up your answer instead of adding yet another TI-85 or HP-49 to the list, and add comments to that answer if you want to relate specifics. EDIT: I moved my photo into an answer for polling.

    Read the article

  • application trying to connect to mirrored sql db

    - by hp
    Hello, We have 4 web servers that host our asp.net (3.5) application. Randomly, we get error messages like : 1) "Login failed for user 'userid'" 2) "A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider: Named Pipes Provider, error: 40 - Could not open a connection to SQL Server)" we are running sql2005 and have a principle and a mirror db (sync). When these exceptions are thrown, I look at the SQL error logs on the mirrored db and noticed the failed login messages in there. The principle db is running fine and the other web apps are working great. this will happen for maybe 10 min, then the app pool recycles and it starts hitting the principle db again. Is there a configuration I have incorrect? my theory is that our principle db is forwarding the request to the mirror, but that should never happen. any help??

    Read the article

  • building a new pc - no display, no beeps

    - by Adam
    Hi Building a new pc using this motherboard: GA-MA785GMT-UD2H and a 500W power supply (1 x 20 pin & 1 x 4 pin connectors). The CPU fan, hard drive and power supply all spin up but no display on the monitor and no beeps. Have tried: taking out all of the memory and still no beeps used a different power supply and still no display I only have the Motherboard, memory, CPU, heat sink & fan & power supply connected. Any ideas? Do I have a faulty motherboard?

    Read the article

  • My home router randomly disconnects me and I'm unable to reconnect to it

    - by Roy Tang
    It's happened a few times, I'm not sure how to diagnose/debug, so any advise would be appreciated. Symptons: sometimes the router will randomly disconnect; the connection icon on my desktop (wired to the router) gets that yellow "!" symbol that tells me my connection just went down. At this point I'm unable to ping the router. afterwards I try to reset the router by removing then reconnecting the power jack on the router side (this is the fastest way as I can't reset the power strip it's connected to without rebooting my desktop. the router has a reset thingy, but it's one of those things where i have to find a pin to stick into the hole, and when I get disconnected I usually need to get reconnected immediately so I just pull and put back the power jack), but even after that the connection has the same state. after the router reboots, if I try to connect to it using a wifi device like my ipad, the ipad prompts me for the wifi password even though it had already "remembered" all the settings for this router forever after i finally decide to reboot the power strip, and my desktop and the router boot up again, the connection returns to its normal state somewhat and i'm able to connect to it as normal using the desktop and wifi devices. What do I need to check the next time this happens so I can figure out the problem? Is it possibly because we've been using the power jack on the router as an easier way to reboot it? Should I be shopping around for a new router? If it helps, the router is a DLink DIR-300

    Read the article

  • Windows Media Player on top other DIV

    - by HP
    I have an embed window media player which is always on top of other DIV tags. I used wmode = opaque; WindowlessVideo = -1 but it does not help. Does anyone know how to make it appear below a certain element of the page. <object type="application/x-oleobject" classid="CLSID:6BF52A52-394A-11D3-B153-00C04F79FAA6" codebase= "http://activex.microsoft.com/activex/controls/mplayer/en/nsmp2inf.cab#Version=5,1,52,701" width="345" height="45"><param name="URL" value= "http://nhacso.net/Music/nghe_song.aspx?id=100004995" /> <param name="EnableContextMenu" value="0" /> <param name="uiMode" value="full" /> <param name="stretchToFit" value="True" /> <param name="AnimationAtStart" value="false" /> <param name="playcount" value="10" /> <param name="Volume" value="100" /> <param name="autostart" value="0" /> <param name="wmode" value="opaque" /> <param name="WindowlessVideo" value="-1" /> <embed src="http://nhacso.net/Music/nghe_song.aspx?id=100004995" type="application/x-mplayer2" width="345" height="45" align= "center" border="0" autostart="0" transparentatstart="1" animationatstart="1" showcontrols="true" showaudiocontrols="1" showpositioncontrols="0" enablecontextmenu="0" autosize="0" showstatusbar="1" displaysize="false" playcount="10" wmode="opaque" windowlessvideo="-1" /></object> Thanks

    Read the article

  • Holding off Windows 2000/3 Server in Shutdown

    - by user1668993
    We have a C# VS2010 application running on a Windows 2000 Server box (there is also a Windows 2003 Server box) as pretty much the only application running. We remove power from the box. There is a short duration battery (maybe 3 minutes of power) which then waits 10 seconds and then decides things are coming down and notifies Windows that it needs to shut down. Windows sends a CTRL_SHUTDOWN_EVENT event to the application which fields it and tries to keep Windows from going down for a while to let another computer which communicates with this one time to do some file work on the first computer. It does this by a timing loop and after the loop is over, it exits gracefully and the computer shuts down. Nice plan but it doesn't work. The application gets to maybe 20 seconds and the application is forcibly killed by Windows and Windows shuts down. At 90 seconds, the hardware firmware running the battery turns off power to the computer. I have tried searching to find out how to hold off Windows for a bit of time. I tried creating (it wasn't there) the HKEY_LOCAL_MACHINE subtree: \SYSTEM\CurrentControlSet\Control\WaitToKillAppTimeout registry key to 60000 but though it seemed to keep the popup from happening, Windows itself died at about the same amount of time -- we think without having the opportunity to shut itself down gracefully. Maybe the registry key worked but wasn't enough. Basically I have an "ill-mannered" application which is refusing to shut down (for the best of reasons) and without the registry key thing, Windows eventually shuts it down anyway and then shuts itself down. With the registry change, we think what is happening is that Windows doesn't shut down the application but Windows itself is killed suddenly without shutting down but power is still not pulled for about another minute, and then power is pulled. So maybe we have layers here. First there is how long the application tries to stay open. Then there is how long Windows is prepared to allow it to stay open. Then there is ... something... which kills windows. Then there is the power loss. Anyone have any ideas how we can get windows to stay open and in operation say to 70 seconds instead of about 20? Is our registry key right, but not enough? Is there some additional key we need to set to determine how long after windows is notified of a shutdown before it just kills itself? Thanks in advance.

    Read the article

  • Add page item to either Joomla, Drupal or Wordpress

    - by HP
    I just want to design this very simple website. Basically there are multiple pages A, B, C... and each page has item A1, A2.. or B1, B2... These items follow fixed HTML template (table,image) and only specific content fields (name, body text..) can be change in the back-end. Backend users can add new pages or new items each page. Does anyone know some plugin for either Joomla, Drupal or Wordpress that can do the simple purpose above? Thanks

    Read the article

  • javascript button click casuing Internet Explorer secuirty exception...

    - by hp
    Hello, I have a application that allows a user to choose some parameters for a powerpoint report, run the report, then allow the user to "save" or "open" the powerpoint file. I got all of that working OK. When you click on "run" report, it pops open a window which generates the report, stores it in session, then closes the window. I have a button on the main page that will export the report. So, now, when the pop up window that generates the report is finished, i use "window.opener" to call a javascript method on the main page, that will do a javascript click of the button. when this button is pressed, Internet Explorer gives me the following message : "To help protect your security, Internet Explorer blocked this site from downloading files to your computer.." Do you guys know of any tricks around this?

    Read the article

  • Battery notification always showing 'xx% remaining' with Windows 7 on an acer Aspire 5590

    - by dindeman
    My battery level always shows up as something like 55% remaining or 63% remaining ...etc despite that it is in fact charging. Additionally it doesn't go any further than 80% remaining even if I keep it in charge forever. This leads me to a side annoying effect which is that I cannot proceed to install Windows 7 Service Pack 1 as its installer requires the laptop to be plugged with a power cord. My laptop is plugged with the power cord but because of the above issue (it doesn't display anything else than the xx% remaining) Windows thinks that the laptop is using its battery and that the power cord is disconnected. I have installed the original acer ePower Management tool that let you configure the power scheme... etc, I was hoping that this would help me circumvent the 80% issue but it doesn't.

    Read the article

  • Finding files with bash and copy to another location and reducing depth of folders

    - by Kevin F
    I'm trying to recover a mates hard drive, there is no structure what so ever so music and images are everywhere but in named folders sometimes 5 folders deep, I've managed to write a one-liner that finds the files and copies them to a mounted drive but it preserves the file structure completely. What I'm after is a bit of code that searches the drive and copies to another location and copies just the parent folder with the mp3/jpg files within and not the complete path. The other issue I have is the music is /folder/folder/folder/Artist/1.mp3..2.mp3..10.mp3 etc etc so I have to preserve the folder 'Artist' to give him any hope of finding his tracks again. What I have working currently: find /media/HP/ -name *.mp3 -fprintf /media/HP/MUSIC/Script.sh 'mkdir -p "/media/HP/MUSIC/%h" \n cp "%h/%f" "/media/HP/MUSIC/%h/"\n' I then run the script.sh and it does all the copying. Many Thanks

    Read the article

  • Video adapter problem on new motherboard

    - by Dmitriy Matveev
    Something bad happened to my PC several days ago. I wasn't near my PC, so I have no idea about what happened it was just halted. When I tried to boot it was entering infinite loops of a few seconds power up (cpu, hdds, etc) and then power down. I've tried to boot the system with no additional components (that includes hdd, video, network adapters and even memory) connected and that didn't solved the problem, so I've made a decision that most likely it's either some a problem with power unit or with motherboard. I've tried to replace my power unit by another one (which was expected to be working) and the problem didn't resolved again. I've bought a new MB (ASUS P5KPL-AM SE) and tried to get it running with my old CPU and memory (I hope it's still alive). Since this MB include on-board video I've tried to run the PC without installation of mine video. The PC wasn't running and the BIOS was beeping one long signal following by two short (Does it means a video problem?). After that I've installed my video adapter to PCI-E slot and tried to boot the system again and the BIOS was beeping the same. I don't get it. I may expect some problem with CPU and/or memory since I don't know what happened to my PC (maybe some power failure or something different), but not with video and not with on-board video on newly bought MB. How can I understand what's wrong with my system now?

    Read the article

  • problems with Haskell's Number Types

    - by mindeavor.
    I have the following haskell code: fac n = product [1..n] taylor3s w0 f f' f'' t h = w1 : taylor3s w1 f f' f'' (t+h) h where hp i = h^i / fac i w1 = w0 + (hp 1) * f t w0 + (hp 2) * f' t w0 + (hp 3) * f'' t w0 taylor_results = take 4 $ taylor3s 1 f f' f'' 1 0.25 where f t x = t^4 - 4*x/t f' t x = 4*t^3 - 4*(f t x)/t + 4*x/t^2 f'' t x = 12*t^2 - 4*(f' t x)/t + 8*(f t x)/t^2 - 8*x/t^3 taylor_results is supposed to be a use case of taylor3s. However, there is something wrong with the number type inferencing. When I try to compile, this is the error I get: practice.hs:93:26: Ambiguous type variable `a' in the constraints: `Integral a' arising from a use of `taylor3s' at practice.hs:93:26-51 `Fractional a' arising from a use of `f' at practice.hs:93:37 Possible cause: the monomorphism restriction applied to the following: taylor_results :: [a] (bound at practice.hs:93:0) Probable fix: give these definition(s) an explicit type signature or use -XNoMonomorphismRestriction Can someone help me with understanding what the problem is?

    Read the article

  • Optimal search queries

    - by Macros
    Following on from my last question http://stackoverflow.com/questions/2788082/sql-server-query-performance, and discovering that my method of allowing optional parameters in a search query is sub optimal, does anyone have guidelines on how to approach this? For example, say I have an application table, a customer table and a contact details table, and I want to create an SP which allows searching on some, none or all of surname, homephone, mobile and app ID, I may use something like the following: select * from application a inner join customer c on a.customerid = a.id left join contact hp on (c.id = hp.customerid and hp.contacttype = 'homephone') left join contact mob on (c.id = mob.customerid and mob.contacttype = 'mobile') where (a.ID = @ID or @ID is null) and (c.Surname = @Surname or @Surname is null) and (HP.phonenumber = @Homphone or @Homephone is null) and (MOB.phonenumber = @Mobile or @Mobile is null) The schema used above isn't real, and I wouldn't be using select * in a real world scenario, it is the construction of the where clause I am interested in. Is there a better approach, either dynamic sql or an alternative which can achieve the same result, without the need for many nested conditionals. Some SPs may have 10 - 15 criteria used in this way

    Read the article

  • How to define a history chart in crystal reports .net (2008)?

    - by hp
    Hi, I want to display a Bar Chart in a Report that shows the sum of a measure grouped by month for the last 24 month. The months that do not have any tuples do not show up in the graph. I do not want that. I want exactly 24 groups/bars that are 0 if there are no tuples. What is the best way to do this? thanks

    Read the article

  • SQL SERVER – Four Tutorial for SQL Server 2012 New Features

    - by pinaldave
    One of the very common question I receive on my facebook is that if there is any tutorial for SQL Server 2012 new enhanced features and solutions. I see this demand a bit increasing as the SQL Server 2012 is more and more being adopted. Here is the list of four tutorial which is specifically created for SQL Server 2012 by Microsoft. Multidimensional Modeling (Adventure Works Tutorial) This tutorial teaches you how to develop and deploy an Analysis Services project that enables the employees of Adventure Works Cycles to analyze various aspects of their business. Tabular Modeling (Adventure Works Tutorial) This tutorial teaches you how to create a SQL Server 2012 Analysis Services tabular model that enable sales and marketing teams to easily analyze internet sales data in the AdventureWorksDW2012 data warehouse. You will build the tabular model in SQL Server Data Tools. Tutorials and Demos for Power View Create Power View reports and explore Power View features. View demos, videos, and tutorials that help you get started quickly with Power View and successfully build reports with interactive filters and visualizations such as bubble charts, tiles, and cards. Tutorial: Using the hierarchyid Data Type This tutorial is intended for users who are experienced with Transact-SQL, but are new to the hierarchyid data type. In this tutorial, you convert an existing table to a hierarchical structure, and you also create a new table to store and manage hierarchical data efficiently. Note: The description of the course is taken from original course description. You will need to install SQL Server 2012 AdventureWorks for all this tutorial. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, SQL Training, T SQL, Technology

    Read the article

  • SATA errors reported during boot: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0

    - by digby280
    I have noticed some error during the Linux boot. They seem to continue to occur after the boot adding lines to the log every few seconds. Once booted this normally does not appear to be causing any problems. However, around 1 in 10 boots results in a kernel panic and the computer has on two or three occasions suddenly rebooted after being powered on for a number of hours. I presume the cause of the reboot is a kernel panic as well. I am running Ubuntu 11.10 and I have had Ubuntu installed on the computer for around a year. I have googled around and not found anything useful. I have provided the kernel log lines and the output of smartctl. Can anyone explain exactly what these errors mean, or better still how to resolve them? Apr 2 16:51:27 dell580 kernel: [ 19.831140] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:27 dell580 kernel: [ 19.934194] tg3 0000:03:00.0: eth0: Link is down Apr 2 16:51:28 dell580 kernel: [ 20.929468] tg3 0000:03:00.0: eth0: Link is up at 100 Mbps, full duplex Apr 2 16:51:28 dell580 kernel: [ 20.929471] tg3 0000:03:00.0: eth0: Flow control is on for TX and on for RX Apr 2 16:51:28 dell580 kernel: [ 20.929727] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready Apr 2 16:51:29 dell580 kernel: [ 21.609381] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:29 dell580 kernel: [ 21.616515] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:29 dell580 kernel: [ 21.616519] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:29 dell580 kernel: [ 21.616525] ata2.00: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 21.934036] ata2.01: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 22.408890] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.408907] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.440934] ata2.00: configured for UDMA/100 Apr 2 16:51:29 dell580 kernel: [ 22.449040] ata2.01: configured for UDMA/133 Apr 2 16:51:29 dell580 kernel: [ 22.449818] ata2: EH complete Apr 2 16:51:33 dell580 kernel: [ 26.122664] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:33 dell580 kernel: [ 26.122670] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:33 dell580 kernel: [ 26.122677] ata2.00: hard resetting link Apr 2 16:51:33 dell580 kernel: [ 26.442684] ata2.01: hard resetting link Apr 2 16:51:34 dell580 kernel: [ 26.925545] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.925561] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.961542] ata2.00: configured for UDMA/100 Apr 2 16:51:34 dell580 kernel: [ 26.969616] ata2.01: configured for UDMA/133 Apr 2 16:51:34 dell580 kernel: [ 26.970400] ata2: EH complete Apr 2 16:51:35 dell580 kernel: [ 28.111180] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:35 dell580 kernel: [ 28.111184] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:35 dell580 kernel: [ 28.111191] ata2.00: hard resetting link Apr 2 16:51:35 dell580 kernel: [ 28.429674] ata2.01: hard resetting link Apr 2 16:51:36 dell580 kernel: [ 28.904557] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.904572] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.936609] ata2.00: configured for UDMA/100 Apr 2 16:51:36 dell580 kernel: [ 28.944692] ata2.01: configured for UDMA/133 Apr 2 16:51:36 dell580 kernel: [ 28.945464] ata2: EH complete Apr 2 16:51:38 dell580 kernel: [ 31.581756] eth0: no IPv6 routers present Apr 2 16:51:38 dell580 kernel: [ 32.103066] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:38 dell580 kernel: [ 32.103074] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:38 dell580 kernel: [ 32.103085] ata2.00: hard resetting link Apr 2 16:51:38 dell580 kernel: [ 32.419669] ata2.01: hard resetting link Apr 2 16:51:39 dell580 kernel: [ 32.894518] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.894533] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.926536] ata2.00: configured for UDMA/100 Apr 2 16:51:39 dell580 kernel: [ 32.934715] ata2.01: configured for UDMA/133 Apr 2 16:51:39 dell580 kernel: [ 32.935578] ata2: EH complete Here's the output of smartctl for the drive. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.0.0-17-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT Device Model: SAMSUNG HD103UJ Serial Number: S13PJ90QC19706 LU WWN Device Id: 5 0000f0 00b1c7960 Firmware Version: 1AA01113 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3b Local Time is: Mon Apr 2 17:13:48 2012 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 41) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: (11772) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 197) minutes. Conveyance self-test routine recommended polling time: ( 21) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 076 076 011 Pre-fail Always - 7940 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 521 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 642 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 482 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 759 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 073 069 000 Old_age Always - 27 (Min/Max 16/27) 194 Temperature_Celsius 0x0022 073 067 000 Old_age Always - 27 (Min/Max 16/28) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 320028 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 099 099 000 Old_age Always - 1494 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 211 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 211 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 0f 31 63 8f e1 Error: ICRC, ABRT 15 sectors at LBA = 0x018f6331 = 26174257 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 40 62 8f e1 08 00:01:00.460 READ DMA c8 00 20 00 7c 30 e0 08 00:01:00.450 READ DMA c8 00 00 10 49 8f e1 08 00:01:00.440 READ DMA c8 00 e0 20 d0 30 e0 08 00:01:00.420 READ DMA c8 00 00 c0 59 90 e1 08 00:01:00.400 READ DMA Error 210 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 cf e9 cf 66 e0 Error: ICRC, ABRT 207 sectors at LBA = 0x0066cfe9 = 6737897 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 b8 cf 66 e0 08 00:08:29.780 READ DMA c8 00 60 60 c9 18 e0 08 00:08:29.770 READ DMA c8 00 40 20 c9 18 e0 08 00:08:29.770 READ DMA c8 00 20 00 c9 18 e0 08 00:08:29.760 READ DMA c8 00 20 98 cf 66 e0 08 00:08:29.750 READ DMA Error 209 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 2f d1 74 e0 e0 Error: ICRC, ABRT 47 sectors at LBA = 0x00e074d1 = 14709969 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 00 74 e0 e0 08 00:00:30.940 READ DMA c8 00 20 18 36 de e0 08 00:00:30.930 READ DMA c8 00 08 48 f1 dd e0 08 00:00:30.930 READ DMA c8 00 08 a8 f0 dd e0 08 00:00:30.930 READ DMA c8 00 08 90 f0 dd e0 08 00:00:30.930 READ DMA Error 208 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 7f 21 88 9d e0 Error: ICRC, ABRT 127 sectors at LBA = 0x009d8821 = 10324001 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 a0 00 88 9d e0 08 00:00:27.610 READ DMA c8 00 58 a8 e7 9c e0 08 00:00:27.610 READ DMA c8 00 00 28 e6 9c e0 08 00:00:27.610 READ DMA c8 00 00 e0 e4 9c e0 08 00:00:27.610 READ DMA c8 00 00 90 e0 9c e0 08 00:00:27.600 READ DMA Error 207 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 26 6a 6a c3 e0 Error: ABRT at LBA = 0x00c36a6a = 12806762 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- ca 00 00 90 69 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 68 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 50 65 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 d0 64 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 63 c3 e0 08 00:29:39.350 WRITE DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Interrupted (host reset) 90% 638 - # 2 Short offline Interrupted (host reset) 90% 638 - # 3 Extended offline Interrupted (host reset) 90% 638 - # 4 Short offline Interrupted (host reset) 90% 638 - # 5 Extended offline Interrupted (host reset) 90% 638 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • TCO Comparison: Oracle Exadata vs IBM P-Series

    - by Javier Puerta
    Cost Comparison for Business Decision-makersOracle Exadata Database Machine vs. IBM Power SystemsHow to Weigh a Purchase DecisionOctober 2012 Download full report here In this research-based  white paper conducted at the request of Oracle, The FactPoint Group compares the cost of ownership of the Oracle Exadata engineered system to a traditional build-your-own (BYO) solution, in this case an IBM Power 770 (P770) with SAN storage.  The IBM P770 was chosen given it is IBM’s current most popular model, based on FactPoint primary and secondary research and IBM claims, and because at least one of the interviewed customers had specifically migrated from a P770 to Exadata, affording us a more specific data point for comparison. This research found that Oracle Exadata: Can be deployed more quickly and easily requiring 59% fewer man-hours than a traditional IBM Power Systems solution. Delivers dramatically higher performance typically up to 12X improvement, as described by customers, over their prior solution.  Requires 40% fewer systems administrator hours to maintain and operate annually, including quicker support calls because of less finger-pointing and faster service with a single vendor.  Will become even easier to operate over time as users become more proficient and organize around the benefits of integrated infrastructure. Supplies a highly available, highly scalable and robust solution that results in reserve capacity that make Exadata easier for IT to operate because IT administrators can manage proactively, not reactively.  Overall, Exadata operations and maintenance keep IT administrators from “living on the edge.”  And it’s pre-engineered for long-term growth. Finally, compared to IBM Power Systems hardware, Exadata is a bargain from a total cost of ownership perspective:  Over three years, the IBM hardware running Oracle Database cost 31% more in TCO than Exadata.

    Read the article

  • Sys Admins are kind of like gods, aren't they? [closed]

    - by user75798
    A systems administrator has root access to the entire system. There is nothing they cannot do. They are omnipotent. Their power is absolute. Nothing dan stand before them. Like Sauron, the Dark Lord, they do not share power. There can be but one root. Else contradiction at the most fundamental level is possible, and that can not be tolerated. The sys admin's power is unconditional and non-negotiable. To be a sys admin is like being a god. (And if they are a god, what is the religion?) There is an old saying that absolute power corrupts absolutely. I wonder whether being a sys admin has ended up warping an individual. Perhaps a sys admin has become crazed or even gone berserk? Surely sys admins must need to be very level headed people. For example, imagine being 'the' sys admin for the NSA. (What an awesome job that would be!) Think about the access to data, the encryption keys, the secrets... Perhaps one day a sys admin might go bonkers, turn up for work and 'uninstall the entire NSA'! :) But you would have the same sorts of responsibilities working at a bank or other organization. I wonder whether much emphasis is put on ensuring that sys admins are level headed in the first place and kept sweet in the second. Do they get paid well? I am sure they do not receive half of what they are worth, considering all the hard earned knowledge they have had to gain and the massive responsibility they have.

    Read the article

  • Second Monitor Detected, but not receiving a signal after upgrading to 12.04

    - by user62458
    After I upgraded to 12.04, my second monitor is detected (in display settings), but will not power on. I have scoured the Internet and forums for a solution and I can't find anything. I have found a couple people with the same problem, but never a solution for it. I am no expert, but I'm certainly not a noob. My computer uses AMD Radeon 6250 graphics, but I do NOT want to use the proprietary graphics drivers. They refuse to work properly with my second monitor (they ATI drivers will only mirror screens, and I've done everything to try to fix it, and I DON't want mirrored screens) Not to mention that the default open-source video drivers seem to work much better than the proprietary anyway! Again, Ubuntu's default video drivers work fine, and they even DETECT the second monitor (Dell 19'). I can drag stuff off the screen and put it on the 'space' of the second monitor and even a screen-shot shows that there are two monitors active; but the monitor is OFF. It will not power on. It goes into 'power-save' mode because it is not receiving a signal. For some reason it is not getting the signal to power on, even though Ubuntu thinks the monitor is working properly. I had this working fine on my Sony VAIO yesterday (with Radeon graphics/default Ubuntu video drivers). I upgraded to a Samsung Series 3 and now I have this issue. I can't for the life of me figure out why the monitor is connected, detected and I have screen space for the monitor, but the screen won't turn on! XRANDR Output: Screen 0: minimum 320 x 200, current 1366 x 768, maximum 8192 x 8192 VGA-0 connected (normal left inverted right x axis y axis) 1440x900 59.9 + 75.0 1280x1024 75.0 60.0 1152x864 75.0 1024x768 75.1 70.1 60.0 832x624 74.6 800x600 72.2 75.0 60.3 56.2 640x480 72.8 75.0 66.7 60.0 720x400 70.1 LVDS connected 1366x768+0+0 (normal left inverted right x axis y axis) 344mm x 194mm 1366x768 60.1*+ 1280x720 59.9 1152x768 59.8 1024x768 59.9 800x600 59.9 848x480 59.7 720x480 59.7 640x480 59.4 HDMI-0 disconnected (normal left inverted right x axis y axis)

    Read the article

  • How to adjust the shooting angle of an object

    - by Blue
    I've been trying to add an angle adjustment feature to a power bar that I got from unity3dStudents. But I can't seem to get the code right. I'm using addforce to rigidbody, it works but the power is too great. I also found that rotating the object it's shooting from changes the angle. But I don't know how to proceed from that. Can somebody show me the problem with the script below, as in how to add height to the addforce without it going to far up or to the side? Or how to change the angle of the object? var theAngle : int; var maxAngle : int = 130; var minAngle : int = 0; var angleIncreasing : boolean = false; var angleDecreasing : boolean = false; var rotationSpeed : float = 10; var ball : Rigidbody; var spawnPos : Transform; var shotForce : float = 25; function Update () { if(Input.GetKeyDown("k")){ angleIncreasing = true; angleDecreasing = false; } if(Input.GetKeyUp("k")){ angleIncreasing = false; } if(Input.GetKeyDown("l")){ angleIncreasing = false; angleDecreasing = true; } if(Input.GetKeyUp("l")){ angleDecreasing = false; } ------- if(angleIncreasing){ theAngle += Time.deltaTime * rotationSpeed; if(theAngle > maxAngle){ theAngle = maxAngle; } } if(angleDecreasing){ theAngle -= Time.deltaTime * rotationSpeed; if(theAngle < minAngle){ theAngle = minAngle; } } } function Shoot(power : float, angle : int){ ---- var forward : Vector3 = spawnPos.forward; var upward : Vector3 = spawnPos.up; pFab.AddForce(forward * power * shotForce); pFab.AddForce(upward * angle * 10); ---- }

    Read the article

< Previous Page | 82 83 84 85 86 87 88 89 90 91 92 93  | Next Page >