  • Fail to start windows after Ubuntu 11.10 install

    - by user49995
    Computer: HP Pavilion dv7-6140eo OS: Originally Win7 I recently decided to try out Ubuntu, and I decided to dual-boot it with Windows 7. First I googled some how-to's, then I downloaded Ubuntu onto a memory stick and made a second partition (I originally only had one partition that I shrunk and used the unallocated space to install onto during the Ubuntu install). During the install I set format type to xt4 (or something, it was the default option), chose the "in the beginning" option and set the last option as "\". The install was successful. Although, when I restarted my computer I weren't able to choose which operating system to start; it went right into windows. After showing the windows logo for half a second before rebooting, I get a blue screen (see bottom of the page). Trying to fix it, I deleted the newly made partition I had just installed Ubuntu onto (seeing it wasn't working either). This made no difference. I proceeded with installing Ubuntu again, so I would at least have a functioning computer, and now Ubuntu works fine (on it now). The only difference on start-up is that I get a Grub window asking me to between several options including Linux and Windows 7 (loader). Now, if I choose Windows 7, I get the message "Windows was unable to start. A recent software or hardware change might be the cause". It recommends me to choose the first option of the two it provides; to start start-up repair tool. The second option being starting windows normally. If I start windows normally, the same thing happens as earlier. My computer does not have a windows installation CD. Although, it has (at least it used to, if I haven't screwed that too up) a 17gb recovery partition. In addition I made an image of the computer onto a external hard drive when I first got it. Though, I have no idea how to use either. If anyone has any idea how I can make windows work again or reinstall it (already backed up my files) it would be greatly appreciated. I still prefer to dual boot between the two functioning operating systems, but I will settle for a functioning windows 7. Thanks a lot for any replies. Blue screen: A problem has been detected and Windows has been shut down to prevent damage to your computer. If this is the first time you've seen this Stop error screen, restart your computer. If this screen appears again, follow these steps: Check for viruses on your computer. Remove and newly installed hard drives or hard drive controllers. Check your hard drive to make sure it is properly configures and terminated. Run CMKDSK /F to check for hard drive corruption, and then restart your computer. Technical information: **STOP: 0x0000007B (0xFFFFF880009A97E8,0xFFFFFFFFC0000034, 0x0000000000000000,0x0000000000000000

    Read the article

  • Live-Ubuntu 12.04 ran fine, now stopped booting!

    - by user89743
    I've seen similar problems to this several times in the forum, but mine is a bit different, so the other posts I saw were no help to me. When I boot Ubuntu 12.04 64-bit from live-SD-card (3GB persistence) I suddenly get this error: (initramfs) mount: mounting /dev/loop0 on //filesystem.squashfs failed: Invalid argument Can not mount /dev/loop/0 (/cdrom/casper/filesystem.squashfs) on //filesystem.squashfs (it says I can type "help" for commands, but I don't know anything about how to go from there, totally new to linux) The reason I say my case is different is because my Ubuntu worked fine for over a week, even pretty fast, and now this problem happened. Before that I used to run my live ubuntu from USB sticks but that was slower (especially when booting which took 15 minutes from USB stick!). Also I kept getting the same above problem after a while when booting and had to re-create a live USB linux several times. Installing on harddrive is not an option because my harddrive has physical damage and getting a replacement will take a while, therefore I can only use live-USB or live-SD-card Ubuntu. As I said I used Ubuntu without problems for more than a week, before that as well for several weeks on USB sticks, but the above problem occured sooner or later. This time I paid attention to when it happened: I was rebooting my computer (HP 620 laptop, 4 GB RAM, 64 bit system) from SD flash card and when I was booting I selected F6 and then the first option "no acpi" or something like that...I had used it before and noticed it slowed down the time it took Linux to use. This time it caused this error. Now even when I boot normally/default I get this error. Now I'm accessing Ubuntu from my USB stick without persistence file, when I check my SD card, all the files mentioned in the error message are there and the filesystem.squashfs is 691.2 MB so nothing seems to have been deleted by accident. (I have already made many changes/downloaded programs to my SD card persistent Ubuntu and would hope to loose them, since downloading is expensive for me, and since the problem seems to re-occur...) Can anyone help me, preferably without having to create another startup disk on my SD card? I'm totally new to this. Sorry for the long posts, just didn't know what info is relevant and what isnt! Kon

    Read the article

  • Why wifi doesn't work in this case?

    - by xRobot
    I have a brand new notebook where I have installed Windows 7 and Ubuntu 12.04 LTS 64bit in dual boot. In windows 7 wifi works but in Ubuntu not. Could you help me please ? iwconfig lo no wireless extensions. wlan0 IEEE 802.11bgn ESSID:off/any Mode:Managed Access Point: Not-Associated Tx-Power=20 dBm Retry long limit:7 RTS thr:off Fragment thr:off Encryption key:off Power Management:off eth0 no wireless extensions. lshw -C network *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:01:00.0 logical name: eth0 version: 07 serial: b4:b5:1f:1b:9a:56 size: 10Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half firmware=rtl8168e-3_0.0.4 03/27/12 latency=0 link=no multicast=yes port=MII speed=10Mbit/s resources: irq:41 ioport:3000(size=256) memory:c2404000-c2404fff memory:c2400000-c2403fff *-network description: Wireless interface product: Ralink corp. vendor: Ralink corp. physical id: 0 bus info: pci@0000:02:00.0 logical name: wlan0 version: 00 serial: 84:4b:f4:0a:3a:22 width: 32 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=rt2800pci driverversion=3.2.0-31-generic firmware=0.34 latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:18 memory:c2500000-c250ffff lspci | grep -i net 01:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 07) 02:00.0 Network controller: Ralink corp. Device 539a iwlist scan lo Interface doesn't support scanning. wlan0 Interface doesn't support scanning : Device or resource busy eth0 Interface doesn't support scanning. lsmod Module Size Used by rfcomm 47604 0 bnep 18281 2 bluetooth 180104 10 rfcomm,bnep parport_pc 32866 0 ppdev 17113 0 snd_hda_codec_hdmi 32474 1 snd_hda_codec_realtek 224173 1 joydev 17693 0 hp_wmi 18092 0 sparse_keymap 13890 1 hp_wmi snd_hda_intel 33773 3 snd_hda_codec 127706 3 snd_hda_codec_hdmi,snd_hda_codec_realtek,snd_hda_intel snd_hwdep 13668 1 snd_hda_codec snd_pcm 97188 3 snd_hda_codec_hdmi,snd_hda_intel,snd_hda_codec snd_seq_midi 13324 0 snd_rawmidi 30748 1 snd_seq_midi snd_seq_midi_event 14899 1 snd_seq_midi snd_seq 61896 2 snd_seq_midi,snd_seq_midi_event snd_timer 29990 2 snd_pcm,snd_seq snd_seq_device 14540 3 snd_seq_midi,snd_rawmidi,snd_seq psmouse 97362 0 snd 78855 16 snd_hda_codec_hdmi,snd_hda_codec_realtek,snd_hda_intel,snd_hda_codec,snd_hwdep,snd_pcm,snd_rawmidi,snd_seq,snd_timer,snd_seq_device arc4 12529 2 rt2800pci 18715 0 rt2800lib 58925 1 rt2800pci crc_ccitt 12667 1 rt2800lib rt2x00pci 14577 1 rt2800pci rt2x00lib 51144 3 rt2800pci,rt2800lib,rt2x00pci mac80211 506816 3 rt2800lib,rt2x00pci,rt2x00lib soundcore 15091 1 snd mac_hid 13253 0 uvcvideo 72627 0 videodev 98259 1 uvcvideo v4l2_compat_ioctl32 17128 1 videodev wmi 19256 1 hp_wmi i915 473240 3 cfg80211 205544 2 rt2x00lib,mac80211 eeprom_93cx6 12725 1 rt2800pci drm_kms_helper 46978 1 i915 drm 242038 4 i915,drm_kms_helper i2c_algo_bit 13423 1 i915 snd_page_alloc 18529 2 snd_hda_intel,snd_pcm mei 41616 0 serio_raw 13211 0 video 19596 1 i915 lp 17799 0 parport 46562 3 parport_pc,ppdev,lp usbhid 47199 0 hid 99559 1 usbhid r8169 62099 0 rfkill list: # rfkill list 0: phy0: Wireless LAN Soft blocked: no Hard blocked: no 1: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: no

    Read the article

  • Ubuntu Linux won't display netbook's native resolution

    - by Daniel
    FYI: My Netbook model is HP Mini 210-1004sa, which comes with Intel Graphics Media Accelerator 3150, and has a display 10.1" Active Matrix Colour TFT 1024 x 600. I recently removed Windows 7 Starter from my netbook, and replaced it with Ubuntu 12.10. The problem is the OS doesn't seem to recognise the native display resolution of 1024x600 i.e. the bottom bits of Ubuntu is hidden beneath the screen & the only 2 available resolutions are: the default 1024x768 and 800x600. I've also thought about replacing Ubuntu with Lubuntu or Puppy Linux, as the system does run a bit slow, but I can't, as then I won't be able to access the taskbar and application menu which will be hidden beneath the screen. Only Ubuntu with Unity is currently usable, as the Unity Launcher is visible enough. I was able to define a custom resolution 1024x600 using the Q&A: How set my monitor resolution? but when I set that resolution, there appears a black band at the top of the screen and the desktop area is lowered, with bits of it hidden beneath the screen. I tried leaving it at this new resolution and restarting the system to see if the black band would disappear & the display will fit correctly, but it gets reset to 1024x768 at startup and displays following error: Could not apply the stored configuration for monitors none of the selected modes were compatible with the possible modes: Trying modes for CRTC 63 CRTC 63: trying mode 800x600@60Hz with output at 1024x600@60Hz (pass 0) CRTC 63: trying mode 800x600@56Hz with output at 1024x600@60Hz (pass 0) CRTC 63: trying mode 640x480@60Hz with output at 1024x600@60Hz (pass 0) CRTC 63: trying mode 1024x768@60Hz with output at 1024x600@60Hz (pass 1) CRTC 63: trying mode 800x600@60Hz with output at 1024x600@60Hz (pass 1) CRTC 63: trying mode 800x600@56Hz with output at 1024x600@60Hz (pass 1) CRTC 63: trying mode 640x480@60Hz with output at 1024x600@60Hz (pass 1) Trying modes for CRTC 64 CRTC 64: trying mode 1024x768@60Hz with output at 1024x600@60Hz (pass 0) CRTC 64: trying mode 800x600@60Hz with output at 1024x600@60Hz (pass 0) CRTC 64: trying mode 800x600@56Hz with output at 1024x600@60Hz (pass 0) CRTC 64: trying mode 640x480@60Hz with output at 1024x600@60Hz (pass 0) CRTC 64: trying mode 1024x768@60Hz with output at 1024x600@60Hz (pass 1) CRTC 64: trying mode 800x600@60Hz with output at 1024x600@60Hz (pass 1) CRTC 64: trying mode 800x600@56Hz with output at 1024x600@60Hz (pass 1) CRTC 64: trying mode 640x480@60Hz with output at 1024x600@60Hz (pass 1)

    Read the article

  • Nvidia driver overscan issue second monitor via dvi-d cable

    - by benmichael
    Ok, I know that I have a bit of a bizarre setup, but here goes. I have an old laptop, HP Pavilion 6000. The graphics card in there is a GeForce 7150M. The monitor connection is an old 18pin. The external monitor I use is a Samsung SyncMaster 2333. Don't ask me why, but this monitor only has a dvi-d connection (yes, i have searched it). So I have the monitor plugged into the laptop. If I use any of the Nvidia propriety drivers and try to set the resolution up to 1920x1080 (the monitor's native resolution), I get a massive overscan issue. Over the years I have tried to get this to work, tinkering with my xorg.conf to death. I have also tried this on every Ubuntu since 10.04, on all the corresponding LUbuntus, and on all the Linux Mints since Lisa. Exact same issue. I have even tried it in WinDoze and it works perfectly there (although I did get the error once, but was unable to reproduce it). Using the Open Source drivers it works perfectly iff I switch off the laptop monitor (this makes no difference with the Nvidia drivers). I would have happily gone on using the Open Source drivers, except that since upgrading to LUbuntu 12.10, the Open Source drivers make my monitor completely hazy and have the same overscan issue until I (through the haze, only because I know where things are) go to the monitor settings, activate the laptop's monitor, then deactivate it, and suddenly it comes right. I have to do this every time. So I have to find a way to fix one of them, so I may as well tackle the propriety drivers, hence this overlong question. Amidst other things, I have tried the nvidia-settings, but because it is connected to an 18pin, it detects the monitor as a vga monitor and does not give me overscan correction options. I have tried custom modlines (although there are always more of those try), I have tried using xrandr, and I have tried all the FlatPanelOptions. What I have not tried is a Gentoo build, as I don't have time any more to do that installation, but up to about three years ago when I ran Gentoo exclusively I did not have this issue. Below is an link to an image with a red highlight around the portion of the screen visible to me, the numbers around it are the number of pixels which are cut off. This does seem to drift a few pixels every now and then. Thanks in advance. Nvidia driver issue image

    Read the article

  • ATI Radeon HD7000 Series (Laptop) - Switch Mode Between ATI & Intel Integrated GPU. Stuck on Boot Screen On Intel GPU Selection Mode

    - by Monkey Drone
    Laptop Specs: HP Pavilion G6-2020SE GPUs 1) ATI HD7000 Series 2) Intel Integrated OS Installed: x) Ubuntu 12.04 (64 bit) i) ATI Graphics Card Drivers Installed From AMD website. Note: Graphics Card Drivers are Working Fine in 3D Mode. It runs a little Hot as it should since its a GPU. Observation) AMD Catalyst Control Centre Lets me Choose If I want to run the system in HIGH-END (ATI GPU) OR Intel Integrated (Better battery life) While I am on High End GPU Choice, Ubuntu works fine. Problem) But when I switch to Intel Mode in the AMD CCC and reboot the Machine. Ubuntu goes into 'Low Graphics Mode'. The problem is not that it goes into low graphics mode, it is completely expected since I am no longer using the ATI GPU but the integrated Intel GPU. Problem starts with the 'Selection' of the options. During that screen, I have no mouse on the screen (even tried plugging in an external USB mouse) & No Keyboard functionality. Thus I am left completely disabled to choose any option and load into Ubuntu. The Only thing I can do is switch to a terminal and enable ATI GPU through command-line and Ubuntu works Fine again. Is it a bug that there is no mouse/keyboard available to me during the startup of Ubuntu when its launched in Low-Graphics Mode? Any suggestions on how to pass through that? My palms are sweating as I write this down because the ATI GPU is really heating up my laptop. I dont want to boot into Windows or keep it around any longer than necessary. Please advise with help and directions. Sincerely, MonkeyD Edit1: The Answer by Celso has helped me switch to Intel, thus giving me sufficient battery power. Kudos to Celso. Now I can at least use my laptop for the time being without having it burn hair off my skin. I am still looking for answer to my original question of, 'why is lightdm not working properly when I switch to Intel GPU using ATI HD7000 series official drivers provided by AMD'.

    Read the article

  • 2012 EC Election Ballot open; Meet the Candidates Call tomorrow

    - by heathervc
    The JCP Executive Committee (EC) Election ballot is now open and all of the candidates' nominations materials are now available on JCP.org -- note that two new candidates were nominated late last week:  Liferay and North Sixty-One. It is shaping up to be an exciting election this year! The ratified candidates are:  Cinterion, Credit Suisse, Fujitsu and HP.The elected candidates are (9 candidates, 2 open seats):  Cisco Systems, CloudBees, Giuseppe Dell'Abate, Liferay, London Java Community, MoroccoJUG, North Sixty-One, Software AG, and Zero Turnaround. Tomorrow, 18 October, we will hold an open teleconference for the Java Community to meet the candidates and ask questions regarding their nomination.  We hope you will be able to participate in the call.  Should the time be inconvenient, a recording will be made available for download, and candidate questions may be posted on this blog entry or sent to [email protected]. Topic: Meet the EC Candidates Date: Thursday, October 18, 2012 Time: 9:30 am, Pacific Daylight Time (San Francisco, GMT-07:00) Meeting Number: 807 818 225 Meeting Password: MeetEC ------------------------------------------------------- To join the online meeting (Now from mobile devices) ------------------------------------------------------- 1. Go to https://jcp.webex.com/jcp/j.php?ED=186721592&UID=0&PW=NMmUzNjY5ZTMw&RT=MiM0 2. If requested, enter your name and email address. 3. If a password is required, enter the meeting password: MeetEC 4. Click "Join". To view in other time zones or languages, please click the link: https://jcp.webex.com/jcp/j.php?ED=186721592&UID=0&PW=NMmUzNjY5ZTMw&ORT=MiM0 ------------------------------------------------------- To join the audio conference only -------------------------------------------------------     +1 (866) 682-4770     Outside the US: global access numbers  https://www.intercallonline.com/portlets/scheduling/viewNumbers/listNumbersByCode.do?confCode=6279803 or +1 (408) 774-4073     Conference code: 9454597     Security code: JCPEC (52732)------------------------------------------------------- For assistance ------------------------------------------------------- 1. Go to https://jcp.webex.com/jcp/mc 2. On the left navigation bar, click "Support".

    Read the article

  • How to make my SanDisk Cruzer Blade 4GB disk back to normal?

    - by Jack
    Currently, my SanDisk Cruzer Blade 4GB have become a 64MB Firebird RAW flash drive (thumb drive). I don't know why it become like this but when I plug it into a PC, it suddenly transform itself to become a 64MB flash drive. (From 4 GB to 64 MB, that is a huge change!) I read the following articles: http://forums.sandisk.com/t5/All-SanDisk-USB-Flash-Drives/Cruzer-Blade-will-not-format/td-p/214932 http://forums.whirlpool.net.au/archive/1691847 http://forum.hddguru.com/sandiskfirebird-64mb-t23539.html and notice that their solutions does not work at all. Some of their solution is as follows: Using the HP USB Disk Storage Format Tool (http://files.extremeoverclocking.com/file.php?f=1970), which did not work for me as it could not format. Using the h2testw to see if it is genuine, which did not work for me because it is a RAW partition. Return to the vendor, which I doubt since the product only have 1 year warranty and it has expired. I also notice that the flash drive is very fragile as after a few use, the flash drive have become something like the following: (The upper cover of the USB connector was broken or torn) So, wondering if someone have any good solution to fix it back so that at least I can retrieve my data on the fragile thumb drive.

    Read the article

  • Connection speed drops from 1 Gbps to 10 Mbps (Vista 64)

    - by Kevin Hakanson
    I recently got a Windows Home Server (HP MediaSmart Server EX490) setup so I could do backups and other things. However, I am having trouble on my Vista 64 PC. The backup will be making great progress, then it will just slow down. At one point, I noticed the lights on my Netgear GS105 indicated it was not using a 1000 Mbps connection, but a 10 Mbps one. I checked the Status of Local Area Connection (Intel(R) 82567V-2 Gigabit Network Connection) and that also showed the same slow speed. This has happened several times in the last couple days. When I disabled the network device, and then enabled it, it established the 1 Gpbs connection again. However, some of the times the Sent Bytes Activity on the Status windows indicate that the data flow is still slow (100 to 1000 bytes every couple seconds). Obviously, at this rate I could backup faster to floppy disk. :) My question is how to diagnose and fix this problem. When I look at the Administrative Events, I do a Errors: Bonjour Service 456: ERROR: read_msg errno 10054 (An existing connection was forcibly closed by the remote host.) And a Warning: e1yexpress Intel(R) 82567V-2 Gigabit Network Connection Link has been disconnected. I am suspicious there is some power saving mode. I found a post suggesting System Idle Power Saver(SIPS) may be the issue. I am going to try that, but looking for other suggestions or diagnostic advice. I have several new items in this configuration: server, client software, switch and cat6 cables.

    Read the article

  • VMWare ESX, storage over 2TB

    - by Phliplip
    Hi, First of, i'm a webdeveloper and my server experience lies in setting up FreeBSD servers for webserver. I'm working on a project for at photographer, and i'm hired to develop a new online photo ordering system - where user of course can view their photos :) They have a massive need of storage, thus we have bought a HP G6 and 8x1TB SATA HDD. Our plan is to install VMWare ESX 4.0, running multiple virtual machines; FreeBSD 8 for webserver and some windows servers. Allready done that. Then mount one big storage to the BSD, and share it through Samba to the WinServers. The raid is set up with an array of 2x 1TB to handle the VMs. And the rest is setup as 3 2x1TB to handle the photo-data. Thus 2.73TB for photo-data (the raids are 1+0). Now if we add a datastore in the ESX and add the 3 LUNs we can get a datastore of 2.74TB. But i don't se how i can add this datastore direct to the VM. Only the BSD VM needs access to this. Only way is to create a VirtualDisk, with a max of 2TB (8MB blocksize). This is because the datastore where we save the virtualdisk has a maximum filesize of 2TB. Then add it as a harddisk to the BSD VM. In the 'Add Harddisk' pane for the VM, i see an option for Raw Disk Management. I think this is to access the datastore or the raid directly. Only problem is that its greyed out! Can i access the datastorage directly from the BSD? Without creating and adding virtualdisk.

    Read the article

  • Intel Wireless 4965AGN not achieving N throughput when connected to an Airport Express N network

    - by BenA
    I have an Intel Wireless WiFi Link 4965AGN adaptor in my laptop (HP Pavillion dv2000 series) which is connecting to a 5Ghz-only 802.11n network provided by an Apple Airport Express. The network is using WPA2 encryption. My desktop is also connected the Airport, via a Linksys WUSB600N USB adaptor. Both are running with the latest drivers, and the Airport is running the latest firmware. The Airport is also configured to use wide channels. The problem I have is that I never get throughput above 4MB/s when transferring files between the two machines. Even a pessimistic calculation shows a 270Mbps network as being capable of transfer rates at well above 10MB/s. I'm pretty sure I've isolated the issue to being the Intel adaptor, as wiring the desktop to the AP, and using the Linksys adaptor on the laptop immediately yielded speeds limited by the 100MB/s ethernet connection. I know that 802.11n is still a draft standard, and so mixing kit from different manufacturers can easily lead to poor results, but I was just wondering if anybody else out there has had success with this Intel adaptor on an N network? Or even better, connecting it to an Airport Express? Can anybody give me any advice on how to troubleshoot this issue? I should also mention that the Airport Express doesn't allow you to manually specify channels when running in N mode, and that I've been able to rule out interference from other Wireless LANs by scanning. There aren't any other 5GHz networks in my area. All ideas welcome! Update: A while later, I've just updated to the most recent drivers for both the Intel chip in the laptop, and the USB adaptor. Unfortunately this hasn't improved things :(. If anybody has any advice it would be be gratefully received.

    Read the article

  • Proliant RAID 1 Rebuild Questions

    - by Nicholas
    I have a HP Proliant ML350 G5 server that experienced a power supply failure overnight. The power supply was replaced but unfortunately it got restarted with only 1 disk in the RAID 1 set plugged in. (The raid controller is the build in E200i). The raid BIOS then said on start-up that it had entered Interim Recovery Mode. However I would have expected it to still start up with only the 1 drive. The bios however says that it cannot find a C: drive and enters a reboot loop polling the other boot devices. First question is, is this normal behaviour not to start up on 1 disk? The second drive was then plugged in (all drives are ok) and the raid bios started an automatic rebuild on that disk. This appears to be a background process as there is no progress shown. However based on the light flashing it looks like it is working. My second question is how long will this rebuild take? (36GB 15K SAS drive). I cannot see any error messages and it looks like it is rebuilding the drive ok, but the computer still will not start-up. It still says during the boot up process that the C: drive is not found. If I wait for the rebuild to finish, is it likely to fix itself and find the C: drive? Or is there some other problem here?

    Read the article

  • ZFS - destroying deduplicated zvol or data set stalls the server. How to recover?

    - by ewwhite
    I'm using Nexentastor on a secondary storage server running on an HP ProLiant DL180 G6 with 12 Midline (7200 RPM) SAS drives. The system has an E5620 CPU and 8GB RAM. There is no ZIL or L2ARC device. Last week, I created a 750GB sparse zvol with dedup and compression enabled to share via iSCSI to a VMWare ESX host. I then created a Windows 2008 file server image and copied ~300GB of user data to the VM. Once happy with the system, I moved the virtual machine to an NFS store on the same pool. Once up and running with my VMs on the NFS datastore, I decided to remove the original 750GB zvol. Doing so stalled the system. Access to the Nexenta web interface and NMC halted. I was eventually able to get to a raw shell. Most OS operations were fine, but the system was hanging on the zfs destroy -r vol1/filesystem command. Ugly. I found the following two OpenSolaris bugzilla entries and now understand that the machine will be bricked for an unknown period of time. It's been 14 hours, so I need a plan to be able to regain access to the server. http://bugs.opensolaris.org/bugdatabase/view_bug.do?bug_id=6924390 and http://bugs.opensolaris.org/bugdatabase/view_bug.do;jsessionid=593704962bcbe0743d82aa339988?bug_id=6924824 In the future, I'll probably take the advice given in one of the buzilla workarounds: Workaround Do not use dedupe, and do not attempt to destroy zvols that had dedupe enabled. Update: I had to force the system to power off. Upon reboot, the system stalls at Importing zfs filesystems. It's been that way for 2 hours now.

    Read the article

  • SNMPD running but not listening for connections at random

    - by Lukasz
    OS: CentOS release 5.7 (Final) Net-SNMP: net-snmp-5.3.2.2-14.el5_7.1 (from RPM) Periodically my NMS notifies me that SNMP has gone down on this machine. The service is restored in between 10 to 30 minutes. My NMS also pings and check SSH and those services are not affected during the SNMP outage. SNMPD log file shows that it is working and apparently receiving packets (either from local agents from 127.0.0.1 or from my NMS at 172.16.37.37) however attempting to snmpwalk locally or from the NMS system fails with a timeout. I have 7 of these servers running mixture of CentOS 5.7 and RHEL 5.7 with this specific version of Net-SNMP installed from RPM - none of them have this issue except this one. 5 of the machines (including the NMS system and this problem server) are in the same rack connected using one switch. Restarting SNMPD does not fix the issue - it clears up by itself eventually. Any suggestions where I can begin diagnosing the issue? It's a closed subnet so IPTables is not used. SNMPD config below: # Following entries were added by HP Insight Management Agents at # Tue May 15 10:58:17 CLT 2012 dlmod cmaX /usr/lib64/libcmaX64.so rwcommunity public 127.0.0.1 rocommunity public 127.0.0.1 rwcommunity 3adRabRu 172.16.37.37 rocommunity 3adRabRu 172.16.37.37 rwcommunity 3adRabRu 172.16.37.36 rocommunity 3adRabRu 172.16.37.36 trapcommunity callmetraps trapsink 172.16.37.37 callmetraps trapsink 172.16.37.36 callmetraps syscontact Lukasz Piwowarek syslocation Santiago, Chile # ---------------------- END -------------------- agentAddress udp:161 com2sec rwlocal default public com2sec rolocal default public com2sec subnet default 3adRabRu group rwv2c v2c rwlocal group rov2c v2c rolocal group rov2c v2c subnet view all included .1 access rwv2c "" any noauth exact all all none access rov2c "" any noauth exact all none none

    Read the article

  • SAN Replication for Fault tolerance using EVA4400

    - by Sergei
    Hi Everyone, I hope that someone would point me in the correct direction - it looks like I have no enough konwledge in the subject and timeframes are too tight for me to explore different scenarios in depth.. We have two datacenters few miles away from each other connected by 100 Mbps link.Each datacenter will have 5 BL490 blades with ESX Standard hosting about 50 VMs. Eac hsite has HP eva4400 SAN with SAN replication set up.VC is going to be in the first datacenter and both datacenter are networked. SAN Replication is block level so it seems like I cannot just replicate changes but all writes would have to be replicated.This should not be a problem as link can sustain about 1.8 TB a dayand data can be buffered. I am having trouble however visioning how recovery would work in this case.We don't need instant recovery , I would say 4 hours recovery time is accepted so fancy automatic SRM like DR scenario would not be easily accepted due to the financial reasons, however any comments are welcomed. Current idea is following: replicate LUNs from primary site to the secondary.When disaster strikes, IT personnel switches on ESX hosts on the remote side and connects replicated LUNS to them, then registers VMs and changes IP address. I understand that this seems like horribly manual process and I almost sure I have missed some obvious pitfalls here. Could someone let me know what direction should I go?An articles regarding the subject? This is a brand new setup and we would rather build up basic recovery process and scale it later.I just need to have a right direction to allow for such scalability. Thank you very much in advance!

    Read the article

  • NGINX MIME TYPE

    - by justanotherprogrammer
    I have my nginx conf file so that when ever a mobile device visits my site the url gets rewritten to m.mysite.com I did it by adding the following set $mobile_rewrite do_not_perform; if ($http_user_agent ~* "android.+mobile|avantgo|bada\/|blackberry|blazer|compal|elaine|fennec|hiptop|iemobile|ip(hone|od)|iris|kindle|lge |maemo|midp|mmp|netfront|opera m(ob|in)i|palm( os)?|phone|p(ixi|re)\/|plucker|pocket|psp|symbian|treo|up\.(browser|link)|vodafone|wap|windows (ce|phone)|xda|xiino") { set $mobile_rewrite perform; } if ($http_user_agent ~* "^(1207|6310|6590|3gso|4thp|50[1-6]i|770s|802s|a wa|abac|ac(er|oo|s\-)|ai(ko|rn)|al(av|ca|co)|amoi|an(ex|ny|yw)|aptu|ar(ch|go)|as(te|us)|attw|au(di|\-m|r |s )|avan|be(ck|ll|nq)|bi(lb|rd)|bl(ac|az)|br(e|v)w|bumb|bw\-(n|u)|c55\/|capi|ccwa|cdm\-|cell|chtm|cldc|cmd\-|co(mp|nd)|craw|da(it|ll|ng)|dbte|dc\-s|devi|dica|dmob|do(c|p)o|ds(12|\-d)|el(49|ai)|em(l2|ul)|er(ic|k0)|esl8|ez([4-7]0|os|wa|ze)|fetc|fly(\-|_)|g1 u|g560|gene|gf\-5|g\-mo|go(\.w|od)|gr(ad|un)|haie|hcit|hd\-(m|p|t)|hei\-|hi(pt|ta)|hp( i|ip)|hs\-c|ht(c(\-| |_|a|g|p|s|t)|tp)|hu(aw|tc)|i\-(20|go|ma)|i230|iac( |\-|\/)|ibro|idea|ig01|ikom|im1k|inno|ipaq|iris|ja(t|v)a|jbro|jemu|jigs|kddi|keji|kgt( |\/)|klon|kpt |kwc\-|kyo(c|k)|le(no|xi)|lg( g|\/(k|l|u)|50|54|e\-|e\/|\-[a-w])|libw|lynx|m1\-w|m3ga|m50\/|ma(te|ui|xo)|mc(01|21|ca)|m\-cr|me(di|rc|ri)|mi(o8|oa|ts)|mmef|mo(01|02|bi|de|do|t(\-| |o|v)|zz)|mt(50|p1|v )|mwbp|mywa|n10[0-2]|n20[2-3]|n30(0|2)|n50(0|2|5)|n7(0(0|1)|10)|ne((c|m)\-|on|tf|wf|wg|wt)|nok(6|i)|nzph|o2im|op(ti|wv)|oran|owg1|p800|pan(a|d|t)|pdxg|pg(13|\-([1-8]|c))|phil|pire|pl(ay|uc)|pn\-2|po(ck|rt|se)|prox|psio|pt\-g|qa\-a|qc(07|12|21|32|60|\-[2-7]|i\-)|qtek|r380|r600|raks|rim9|ro(ve|zo)|s55\/|sa(ge|ma|mm|ms|ny|va)|sc(01|h\-|oo|p\-)|sdk\/|se(c(\-|0|1)|47|mc|nd|ri)|sgh\-|shar|sie(\-|m)|sk\-0|sl(45|id)|sm(al|ar|b3|it|t5)|so(ft|ny)|sp(01|h\-|v\-|v )|sy(01|mb)|t2(18|50)|t6(00|10|18)|ta(gt|lk)|tcl\-|tdg\-|tel(i|m)|tim\-|t\-mo|to(pl|sh)|ts(70|m\-|m3|m5)|tx\-9|up(\.b|g1|si)|utst|v400|v750|veri|vi(rg|te)|vk(40|5[0-3]|\-v)|vm40|voda|vulc|vx(52|53|60|61|70|80|81|83|85|98)|w3c(\-| )|webc|whit|wi(g |nc|nw)|wmlb|wonu|x700|xda(\-|2|g)|yas\-|your|zeto|zte\-)") { set $mobile_rewrite perform; } if ($mobile_rewrite = perform) { rewrite ^ http://m.mywebsite.com redirect; break; } I got it from http://detectmobilebrowsers.com/ IT WORKS.But none of my images/js/css files load only the HTML. And I know its the chunk of code I mentioned above because when I remove it and visit m.mywebsite.com from my mobile device everything loads up.So this bit of code does SOMETHING to my css/img/js MIME TYPES. I found this out through the the console error messages from safari with the user agent set to iphone. text.cssResource interpreted as stylesheet but transferred with MIME type text/html. 960_16_col.cssResource interpreted as stylesheet but transferred with MIME type text/html. design.cssResource interpreted as stylesheet but transferred with MIME type text/html. navigation_menu.cssResource interpreted as stylesheet but transferred with MIME type text/html. reset.cssResource interpreted as stylesheet but transferred with MIME type text/html. slide_down_panel.cssResource interpreted as stylesheet but transferred with MIME type text/html. myrealtorpage_view.cssResource interpreted as stylesheet but transferred with MIME type text/html. head.jsResource interpreted as script but transferred with MIME type text/html. head.js:1SyntaxError: Parse error isaac:208ReferenceError: Can't find variable: head mrp_home_icon.pngResource interpreted as image but transferred with MIME type text/html. M_1_L_289_I_499_default_thumb.jpgResource interpreted as image but transferred with MIME type text/html. M_1_L_290_I_500_default_thumb.jpgResource interpreted as image but transferred with MIME type text/html. M_1_default.jpgResource interpreted as image but transferred with MIME type text/html. default_listing_image.pngResource interpreted as image but transferred with MIME type text/html. here is my whole nginx conf file just incase... worker_processes 1; events { worker_connections 1024; } http { include mime.types; include /etc/nginx/conf/fastcgi.conf; default_type application/octet-stream; sendfile on; keepalive_timeout 65; #server1 server { listen 80; server_name mywebsite.com www.mywebsite.com ; index index.html index.htm index.php; root /srv/http/mywebsite.com/public; access_log /srv/http/mywebsite.com/logs/access.log; error_log /srv/http/mywebsite.com/logs/error.log; #---------------- For CodeIgniter ----------------# # canonicalize codeigniter url end points # if your default controller is something other than "welcome" you should change the following if ($request_uri ~* ^(/main(/index)?|/index(.php)?)/?$) { rewrite ^(.*)$ / permanent; } # removes trailing "index" from all controllers if ($request_uri ~* index/?$) { rewrite ^/(.*)/index/?$ /$1 permanent; } # removes trailing slashes (prevents SEO duplicate content issues) if (!-d $request_filename) { rewrite ^/(.+)/$ /$1 permanent; } # unless the request is for a valid file (image, js, css, etc.), send to bootstrap if (!-e $request_filename) { rewrite ^/(.*)$ /index.php?/$1 last; break; } #---------------------------------------------------# #--------------- For Mobile Devices ----------------# set $mobile_rewrite do_not_perform; if ($http_user_agent ~* "android.+mobile|avantgo|bada\/|blackberry|blazer|compal|elaine|fennec|hiptop|iemobile|ip(hone|od)|iris|kindle|lge |maemo|midp|mmp|netfront|opera m(ob|in)i|palm( os)?|phone|p(ixi|re)\/|plucker|pocket|psp|symbian|treo|up\.(browser|link)|vodafone|wap|windows (ce|phone)|xda|xiino") { set $mobile_rewrite perform; } if ($http_user_agent ~* "^(1207|6310|6590|3gso|4thp|50[1-6]i|770s|802s|a wa|abac|ac(er|oo|s\-)|ai(ko|rn)|al(av|ca|co)|amoi|an(ex|ny|yw)|aptu|ar(ch|go)|as(te|us)|attw|au(di|\-m|r |s )|avan|be(ck|ll|nq)|bi(lb|rd)|bl(ac|az)|br(e|v)w|bumb|bw\-(n|u)|c55\/|capi|ccwa|cdm\-|cell|chtm|cldc|cmd\-|co(mp|nd)|craw|da(it|ll|ng)|dbte|dc\-s|devi|dica|dmob|do(c|p)o|ds(12|\-d)|el(49|ai)|em(l2|ul)|er(ic|k0)|esl8|ez([4-7]0|os|wa|ze)|fetc|fly(\-|_)|g1 u|g560|gene|gf\-5|g\-mo|go(\.w|od)|gr(ad|un)|haie|hcit|hd\-(m|p|t)|hei\-|hi(pt|ta)|hp( i|ip)|hs\-c|ht(c(\-| |_|a|g|p|s|t)|tp)|hu(aw|tc)|i\-(20|go|ma)|i230|iac( |\-|\/)|ibro|idea|ig01|ikom|im1k|inno|ipaq|iris|ja(t|v)a|jbro|jemu|jigs|kddi|keji|kgt( |\/)|klon|kpt |kwc\-|kyo(c|k)|le(no|xi)|lg( g|\/(k|l|u)|50|54|e\-|e\/|\-[a-w])|libw|lynx|m1\-w|m3ga|m50\/|ma(te|ui|xo)|mc(01|21|ca)|m\-cr|me(di|rc|ri)|mi(o8|oa|ts)|mmef|mo(01|02|bi|de|do|t(\-| |o|v)|zz)|mt(50|p1|v )|mwbp|mywa|n10[0-2]|n20[2-3]|n30(0|2)|n50(0|2|5)|n7(0(0|1)|10)|ne((c|m)\-|on|tf|wf|wg|wt)|nok(6|i)|nzph|o2im|op(ti|wv)|oran|owg1|p800|pan(a|d|t)|pdxg|pg(13|\-([1-8]|c))|phil|pire|pl(ay|uc)|pn\-2|po(ck|rt|se)|prox|psio|pt\-g|qa\-a|qc(07|12|21|32|60|\-[2-7]|i\-)|qtek|r380|r600|raks|rim9|ro(ve|zo)|s55\/|sa(ge|ma|mm|ms|ny|va)|sc(01|h\-|oo|p\-)|sdk\/|se(c(\-|0|1)|47|mc|nd|ri)|sgh\-|shar|sie(\-|m)|sk\-0|sl(45|id)|sm(al|ar|b3|it|t5)|so(ft|ny)|sp(01|h\-|v\-|v )|sy(01|mb)|t2(18|50)|t6(00|10|18)|ta(gt|lk)|tcl\-|tdg\-|tel(i|m)|tim\-|t\-mo|to(pl|sh)|ts(70|m\-|m3|m5)|tx\-9|up(\.b|g1|si)|utst|v400|v750|veri|vi(rg|te)|vk(40|5[0-3]|\-v)|vm40|voda|vulc|vx(52|53|60|61|70|80|81|83|85|98)|w3c(\-| )|webc|whit|wi(g |nc|nw)|wmlb|wonu|x700|xda(\-|2|g)|yas\-|your|zeto|zte\-)") { set $mobile_rewrite perform; } if ($mobile_rewrite = perform) { rewrite ^ http://m.mywebsite.com redirect; #rewrite ^(.*)$ $scheme://mywebsite.com/mobile/$1; #return 301 http://m.mywebsite.com; #break; } #---------------------------------------------------# location / { index index.html index.htm index.php; } error_page 500 502 503 504 /50x.html; location = /50x.html { root html; } location ~ \.php$ { try_files $uri =404; fastcgi_pass 127.0.0.1:9000; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_param PATH_INFO $fastcgi_script_name; include /etc/nginx/conf/fastcgi_params; } }#sever1 #server 2 server { listen 80; server_name m.mywebsite.com; index index.html index.htm index.php; root /srv/http/mywebsite.com/public; access_log /srv/http/mywebsite.com/logs/access.log; error_log /srv/http/mywebsite.com/logs/error.log; #---------------- For CodeIgniter ----------------# # canonicalize codeigniter url end points # if your default controller is something other than "welcome" you should change the following if ($request_uri ~* ^(/main(/index)?|/index(.php)?)/?$) { rewrite ^(.*)$ / permanent; } # removes trailing "index" from all controllers if ($request_uri ~* index/?$) { rewrite ^/(.*)/index/?$ /$1 permanent; } # removes trailing slashes (prevents SEO duplicate content issues) if (!-d $request_filename) { rewrite ^/(.+)/$ /$1 permanent; } # unless the request is for a valid file (image, js, css, etc.), send to bootstrap if (!-e $request_filename) { rewrite ^/(.*)$ /index.php?/$1 last; break; } #---------------------------------------------------# location / { index index.html index.htm index.php; } error_page 500 502 503 504 /50x.html; location = /50x.html { root html; } location ~ \.php$ { try_files $uri =404; fastcgi_pass 127.0.0.1:9000; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_param PATH_INFO $fastcgi_script_name; include /etc/nginx/conf/fastcgi_params; } }#sever2 }#http I could just detect the mobile browsers with php or javascript but i need to make the detection at the server level so that i can use the 'm' in m.mywebsite.com as a flag in my controllers (codeigniter) to serve up the right view. I hope someone can help me! Thank you!

    Read the article

  • Recommended motherboard with hardware raid for Linux

    - by luison
    Hi. We want to setup an internal office server for testing jobs (LAMP), email and samba. Only about 5-10 users. We are also considering starting to virtualize, initially by a base Ubuntu Server with Xen or VMWare Open Source server. Our current system runs with a Linux Raid which has worked great but it's always been complicated to recover the boot sector when one the drives fail and therefore I would prefer using now a hardware raid instead, but ideally with some kind of software monitoring. For this reason and considering we don't want to spend a fortune a I would appreciate any comments on the following options. Motherboard with RAID with linux support... which could you recommend. Motherboard + Hardware Raid card... Adaptec does not seem to have great Linux suppport. 3Ware seems to have a tc soft controller which we've used on a hosting company, but hard to find here in Spain. HP Proliant type basic server, which? Dell Small Servers... any good for Linux? Thanks in advance for any feedback.

    Read the article

  • Windows 7: Touch gestures in IE not working without explorer.exe being run once

    - by Michael
    Details: Internet Explorer 9 and Windows 7 Professional, running on a HP TouchSmart (touch screen PC). It is going to be a kiosk PC (running a custom GUI for displaying websites). Scenario 1: When running Internet Explorer as a normal program in Windows 7, touch functions work perfectly. I can scroll the website by dragging it with my finger, I can pinch zoom and I can touch-and-hold right click. I now change the default shell in Windows to Internet Explorer (ie. IE starts instead of explorer.exe). Internet Explorer of course starts up when logging in. However, touch functions are reduced to basic clicking (no dragging, no pinch zooming, no touch-and-hold right click). Then I manually start explorer.exe, and the touch functions work again! And here is the weird part: When I kill explorer.exe, the touch functions keeps working - even if I close IE and start a new instance. Scenario 2: The exact same, but instead of changing the default shell to Internet Explorer, I change it to my own program, which uses an embedded Internet Explorer ("WebBrowser"). Same thing happens. What I've tried: Autorun programs: When explorer.exe launches, it launches all the autorun programs. There are no relevant programs being run by explorer, but just in case, I have manually started all the autorun programs, so that it is identical (but without explorer.exe) to a normal login. It still does not work (until I launch explorer.exe). Specifically TabTip.exe, TabTip32.exe and wisptis.exe are all running. All services are also started. To sum it up Running explorer.exe once changes something in the touch capabilities of Internet Explorer. It doesn't matter if explorer.exe is running - as long as it has been run once. Does anyone know what causes this behavior? Or how I can circumvent it neatly? Thanks!

    Read the article

  • Redhat 5.5: Multi-thread process only uses 1 CPU of the available 8

    - by Tonny
    Weird situation: Redhat Enterprise 5.5 (stock install, no updates, x64) on a HP z800 workstation. (Dual Xeon 2,2 Ghz. 8 cores, 16 if you count Hyper-threading. RH sees 16 cores.) We have an application that can utilize 1, 2 or 4 threads for heavy calculations. Somehow all these threads run on the same core at 100% load (the other 15 cores are nearly idle) so there is absolutely no benefit from the extra threads. In fact there is a slight slowdown as the threads get in each others way on the single core. How do I get them to run on separate cores (if possible)? Application is 64 bit. Can't change anything about the software except changing the threads setting. Is there some obscure Linux setting I can try to change? (I'm a True64 and Aix guy. I use Linux, but have no in depth knowledge of the process scheduling on Linux.)

    Read the article

  • Is it necessary to burn-in RAM for server-class systems?

    - by ewwhite
    When using server-class systems with ECC RAM, is it necessary or even useful to burn-in the memory DIMMs prior to deployment? I've encountered an environment where all server RAM is placed through a lengthy multi-day burn-in/stress-tesing process. This has delayed system deployments on occasion and adds an extra step to the hardware lead-time. The server hardware is primarily Supermicro, so the RAM is sourced from a variety of vendors; not directly from the manufacturer like a Dell Poweredge or HP ProLiant. Is this process useful? In my past experience, I simply used vendor RAM out of the box. Isn't that what the POST memory tests are for? I've encountered and responded to ECC errors long before a DIMM actually failed. The ECC thresholds were usually the trigger for warranty placement. Do you burn your RAM in? If so, what method do you use to perform the tests? Has the burn-in process resulted in any additional platform stability? Has it identified any pre-deployment problems?

    Read the article

  • Any ideas out there as to how the data can be recovered from an SSD?

    - by ben
    A friend had some form of catastrophic failure on an HP mini 1000, unbootable. Of course there was data that wasn't backed up. I've removed the SSD and hooked it up to a ZIF 40 enclosure but can not seem to get the drive to be recognized in Windows 7. In Disk Management it displays as present, but uninitialized. Attempting to initialize it presents an error Virtual Disk Manager - "The device is not ready". There is scant information on MIE (the custom OS), so I'm not even sure what kind of file system I'm dealing with. In any case, if the filesystem is indeed some flavor other than FAT or NTFS, is this error consistent with that? Are there any creative ideas out there as to how the data can be recovered? Update: Thanks for all the suggestions! I hadn't even considered running a live cd. Unfortunately no luck with Ubuntu (live cd) or explore2fs. The zif connection seems ok (color coded green led for proper connect, orange for not). The drive can't be initialized and therefore can't be formatted, so I guess there may be some real damage. Probably needs to head to a specialist. Thanks again for the feedback, much appreciated.

    Read the article

  • Linksys/Cisco Small Business SRW-Series (ie SRW248G4) - Overcoming the Limitations

    - by Warren P
    We just purchased a Cisco/Linksys SRW 248G4 switch to try it out. We have always had unmanaged switches before, and this is our first "somewhat managed" switch. So far the major limitations are: Only Internet Explorer 6 (manual says IE 5.5!) works for the web interface SSH exists but is not practically useable because the only key length that is supported is no longer even used by most modern SSH installs. (I get the error "RSA modulus too small" in openssh 4.x/5.x) This is with the latest firmware revision, I believe, although Cisco's website does not actually tell you what version you're downloading. All in all, I think, they must be trying to tell me that if I want a good-quality switch, I shouldn't buy these SRWs and should buy a Dell or an HP ProCurve, or save up my pennies, and buy a Catalyst. The question here, then, at long last: Has anyone gotten the web-browser to work via some IE 7 or IE 8 compatibility mode settings or used another browser (Opera? KDE/Safari/WebKit?) and spoofed IE6? Is there any way to get the SSH key length upgraded? I'm guessing a 0% chance of a yes on that last one. I found an XP machine, used telnet (via PuttyTel.exe) and IE6 to set this up, and I doubt we'll have to touch it again. Which is fine with us. But it would be nice if I could administer this thing from either (a) a linux box, or (b) my primary desktop which is windows 7. It looks like XPMode with IE6 on the virtual XP machine may be my only way to administer this type of switch via the web.

    Read the article

  • Inter-vlan routing issues

    - by DKNUCKLES
    I've been brought in to help administer a network and I've run into an issue - I'm not sure why this one is beyond me, however I figure an extra set of eyes on the problem may help resolve the issue. I have an HP MSM720 controller and at the time I'm trying to set up a basic hotspot set up with access points. For the time being I'm just looking to have people authenticate with a PSK and access the internet and other resources (namely printers) on other vlans. The user authenticates and the DHCP server on the controller gives them a 192.168.1.0/24 address. They are able to successfully browse the internet and ping machines on other networks, however they are unable to print to network printers that sit on the same LANs as the very computers that wireless clients can ping. The (extremely simplified) topology is as follows Computers on the wireless 192.168.1.1 network are able to ping computers on the 192.168.0.0 network, however cannot ping or print to the printers on the same network. I'm baffled and I have no idea why this is the case. Can anyone shed some light on this for me? Can someone spot the error of my configuration? EDIT : It should be noted that for whatever reason other computers on the 10.0.100.0/24 network cannot even ping the gateway of the Wireless Access network (192.168.1.1) - I'm not sure if this is relevant. These are the VLANS listed on the controller.

    Read the article

  • Cisco SG 300-28P PoE switch appears to have damaged my domain server's network IF

    - by cdonner
    I just replaced the old HP ProCurve switch with a new Cisco SG 300-28P managed switch. It has PoE on all ports. Everything works, except for my domain server that went offline and the network interface appears to be dead. Windows says the network cable is disconnected, and no lights blink on the switch. Tried different cables and different ports on the switch. The Cisco PoE ports are supposed to be auto-sensing, i.e. not to send power to a device that cannot handle it. Is this technique not 100% reliable? The server is a SHUTTLE XS35V2 with an onboard network chip, so it is probably fried. My questions: is this plausible? who's fault is it - Shuttle or Cisco (i.e. which support line should I try first)? UPDATE: I did go back and tried another switch between the server and the Cisco switch, and indeed, the connection came back to live. When everything is powered down and I start fresh, with the server connected to the Cisco switch, the port light will blink for a while and the connection status is "No Internet connection" at first until it goes off after about 20 seconds and the connection status changes to "Network cable disconnected". On the other switch it works. Clearly not a PoE issue now. I will start looking into the Cisco's onboard diagnostic functions, but so far I have not noticed anything unusual in the log.

    Read the article

  • ZFS - Impact of L2ARC cache device failure (Nexenta)

    - by ewwhite
    I have an HP ProLiant DL380 G7 server running as a NexentaStor storage unit. The server has 36GB RAM, 2 LSI 9211-8i SAS controllers (no SAS expanders), 2 SAS system drives, 12 SAS data drives, a hot-spare disk, an Intel X25-M L2ARC cache and a DDRdrive PCI ZIL accelerator. This system serves NFS to multiple VMWare hosts. I also have about 90-100GB of deduplicated data on the array. I've had two incidents where performance tanked suddenly, leaving the VM guests and Nexenta SSH/Web consoles inaccessible and requiring a full reboot of the array to restore functionality. In both cases, it was the Intel X-25M L2ARC SSD that failed or was "offlined". NexentaStor failed to alert me on the cache failure, however the general ZFS FMA alert was visible on the (unresponsive) console screen. The zpool status output showed: pool: vol1 state: ONLINE scan: scrub repaired 0 in 0h57m with 0 errors on Sat May 21 05:57:27 2011 config: NAME STATE READ WRITE CKSUM vol1 ONLINE 0 0 0 mirror-0 ONLINE 0 0 0 c8t5000C50031B94409d0 ONLINE 0 0 0 c9t5000C50031BBFE25d0 ONLINE 0 0 0 mirror-1 ONLINE 0 0 0 c10t5000C50031D158FDd0 ONLINE 0 0 0 c11t5000C5002C823045d0 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 c12t5000C50031D91AD1d0 ONLINE 0 0 0 c2t5000C50031D911B9d0 ONLINE 0 0 0 mirror-3 ONLINE 0 0 0 c13t5000C50031BC293Dd0 ONLINE 0 0 0 c14t5000C50031BD208Dd0 ONLINE 0 0 0 mirror-4 ONLINE 0 0 0 c15t5000C50031BBF6F5d0 ONLINE 0 0 0 c16t5000C50031D8CFADd0 ONLINE 0 0 0 mirror-5 ONLINE 0 0 0 c17t5000C50031BC0E01d0 ONLINE 0 0 0 c18t5000C5002C7CCE41d0 ONLINE 0 0 0 logs c19t0d0 ONLINE 0 0 0 cache c6t5001517959467B45d0 FAULTED 2 542 0 too many errors spares c7t5000C50031CB43D9d0 AVAIL errors: No known data errors This did not trigger any alerts from within Nexenta. I was under the impression that an L2ARC failure would not impact the system. But in this case, it surely was the culprit. I've never seen any recommendations to RAID L2ARC. Removing the bad SSD entirely from the server got me back running, but I'm concerned about the impact of the device failure (and maybe the lack of notification from NexentaStor as well). Edit - What's the current best-choice SSD for L2ARC cache applications these days?

    Read the article