Search Results

Search found 1607 results on 65 pages for 'disks'.

Page 9/65 | < Previous Page | 5 6 7 8 9 10 11 12 13 14 15 16  | Next Page >

  • Troubleshooting Windows Server 2012 storage spaces

    - by Iravanchi
    I'm trying the new "Storage Pools" feature on Windows Server 2012, and I've created several disks on the pool. When I restart the server, some of the disks (two, out of four) do not attach automatically, and don't show up in the list of disks. I can go to Server Manager File and Storage Services Storage Pools, and the faulty disks are listed with a yellow triangle beside them. The drive health in the properties are "unknown". But if I right-click and choose attach, the disk comes online, with all the content on it intact. But after another restart, it's the same story. I didn't find any relevant event in the event log, how can I find out why the drives are not attaching?

    Read the article

  • Dell R910 with Integrated PERC H700 Adapter

    - by Alex
    I am in the process of designing an architecture based around a single Dell R910 server running Windows Server 2008 Enterprise. I would like the server to have 8 RAID1 pairs of spinning disks, so I intend to implement: Dell R910 Server Integrated PERC H700 Adapter with 1 SAS expander on each SAS connector (so 8 expanders in total) 7 RAID1 pairs of 143Gb 15K HDD, each paired on one connector using an expander 1 RAID1 pair of 600Gb 10K HDD, paired on the remaining connector using an expander My main concern is not to introduce bottlenecks in this architecture, and I have the following questions. Will the PERC H700 Adapter act as a bottleneck for disk access? Will using SAS expanders for each RAID1 pair cause a bottleneck or would this be as fast as pairing disks directly attached to the SAS connectors? Can I mix the disks, as long as the disks in each RAID1 pair are the same? I assume so. Can anyone recommend any single-to-double SAS Expanders that are known to function well with the H700? Cheers Alex

    Read the article

  • iSCSI RAID1 on two servers, fail scenario

    - by Franz Kafka
    Hallo, a simple question: Image I have two servers, each server has two disks in RAID1. Now I merge the two arrays with iSCSI to one RAID1 disk. Two questions: Can I do the merging of the 4 disks in one go? I can't image how. First I will have to install the os, and then the raid controller is already set up to RAID1. If a whole server fails the other server would continue working without any problems? Does iSCSI notice that the other server is missing and treet this as if the two disks were broken? When the server comes back online the data is resynced, as if I installed new disks into a array? Can I image that this way? Thanks alot.

    Read the article

  • How to create Windows Vista/Windows 7 Startup disk or Rescue disk or system restore points on a CD?

    - by goldenmean
    Hello, I have two laptops, one having Windows-Vista home premium and other one having Windows-7 professional. Both versions of OS are OEM installs(pre-installed when I bought the laptop) and I do not have the Windows Installation disks for them. usually the installation disks provide a repair option in case one needs to repair/rescue a improper windows installation. But since I dont have the installation disks, I want to create rescue disks/startup disks for these. My questions are : 1] How to create a system rescue disk/startup disk on a CD from these two versions of Windows? 2] Doesn't the system restore points which Vista/Windows-7 create, cannot be created on a CD disk instead of hard-disk? 3] If I have a manual backup of my windows registry, in which I have exported all the registry to a file and I have that file on a CD, how to restore that registry back to the windows installation which might not be booting up properly due to bad registry problem. EDIT: 4]Is there any way to use these system restore points directly during bootup of the laptop, if windows does cannot boot properly due to problem. First laptop is HP Pavillion dv6646 and second one is Sony VAIO VCPEE series. thank you. -AD

    Read the article

  • Battery backed write cache behavior upon disk change

    - by Halfgaar
    We use 3ware Inc 9650SE SATA-II RAID PCIe RAID controllers with battery backed write cache. Our spare hardware has the same controller. I was wondering; are these controllers smart enough not to sync the cache when the disks have been changed? For example, if I deploy one of those spare machines by putting in the disks of another machine and that spare machine still has pending writes, will it be smart enough not to perform those writes on the replaced array? Edit: my scenario is not really made clear, so let me give an example: server1 goes down because of power supply failure. I put the disks in server2 and start. I repair server1 I put the disks back from server2 in server1 (it's not relevant right now that in reality I would probably keep server2 running). If server1 doesn't have safeguards, it will write to the array, thinking it's simply powering up again, corrupting it.

    Read the article

  • Dell 2950 Perc 6/i "physical disk" and "Enclosure(Backplane)" under Connector 1 in OMSA tree- Troubleshoot help

    - by user66357
    Just looking for someone who might know why this could occur... In OMSA, on my Dell 2950, there usually is only one "Physical Disks" child under "Enclosure (Backplane)" in the tree view. Currently, the tree looks like this: Dell PERC 6/i Integrated Connector 1 (RAID) Enclosure (Backplane) Physical Disks (1:04 good, 1:05 removed) Physical Disks (1:33 Ready but unused) Normally it's like this: Connector 1 (RAID) Enclosure (Backplane) Physical Disks (1:04 good, 1:05 good) From the front, 6 of 6 3.5" SAS drives are connected. The server is showing Slot 5 as bad and the disk as removed. It seems that the drive in Slot 5 is being sensed as external to the Enclosure. Any ideas why this would happen? Think I can get away with rebuilding the virtual disk by replacing 1:05 with 1:33? Thanks.

    Read the article

  • Can't select hard disk off Windows 7 system image creator

    - by David
    When I try to create a system image in Windows 7 from the Control Panel (Control Panel\All Control Panel Items\Backup and Restore) I get the option to select a hard disk or a removeable disk to select, I have 2 disks and wanted to create the image on my spare one. However when I click refresh it doesn't show either of my disks but shows my CDROM under the removable disks area, anyone have this problem? Also, when I select a USB disk instead, it tries to iamge both my disks! I can't select my active Windows 7 installed disk! How pointless!

    Read the article

  • Question about VMWare thin provisioning

    - by Datapimp23
    I'm playing around with virtual disks and thin provisioning and have a question about it. I've created several disks and allocated space to with thin provisioning. Is it possible to allocate more disk space than the maximum amount of the datastore space. So that for example, my VM's will stop functioning when the disks slowly start filling up?

    Read the article

  • Best practices for thin-provisioning Linux servers (on VMware)

    - by nbr
    I have a setup of about 20 Linux machines, each with about 30-150 gigabytes of customer data. Probably the size of data will grow significantly faster on some machines than others. These are virtual machines on a VMware vSphere cluster. The disk images are stored on a SAN system. I'm trying to find a solution that would use disk space sparingly, while still allowing for easy growing of individual machines. In theory, I would just create big disks for each machine and use thin provisioning. Each disk would grow as needed. However, it seems that a 500 GB ext3 filesystem with only 50 GB of data and quite a low number of writes still easily grows the disk image to eg. 250 GB over time. Or maybe I'm doing something wrong here? (I was surprised how little I found on the subject with Google. BTW, there's even no thin-provisioning tag on serverfault.com.) Currently I'm planning to create big, thin-provisioned disks - but with a small LVM volume on them. For example: a 100 GB volume on a 500 GB disk. That way I could more easily grow the LVM volume and the filesystem size as needed, even online. Now for the actual question: Are there better ways to do this? (that is, to grow data size as needed without downtime.) Possible solutions include: Using a thin-provisioning friendly filesystem that tries to occupy the same spots over and over again, thus not growing the image size. Finding an easy method of reclaiming free space on the partition (re-thinning?) Something else? A bonus question: If I go with my current plan, would you recommend creating partitions on the disks (pvcreate /dev/sdX1 vs pvcreate /dev/sdX)? I think it's against conventions to use raw disks without partitions, but it would make it a bit easier to grow the disks, if that is ever needed. This is all just a matter of taste, right?

    Read the article

  • Can someone explain the physical architecture of RAID 10 in complete layman's terms?

    - by Hank
    I am a newbie in the world of storage and I am having a hard time digesting the physical architecture of some of the RAID levels. I am particularly interested in RAID 10, and 50. I asked the question specifically about RAID 10, because I feel if I understand that, I'll understand the other. So, I get the definition of RAID 10 - "minimum 4 disks, a striped array whose segments are mirrored". If I've got 4 disks and Disks 1 and 2 are a mirrored pair, and Disks 3 and 4 are a mirrored pair - where does the data get striped? Thanks.

    Read the article

  • Server 2008 RAID 5 Write Speeds

    - by Solipsism
    I recently configured a RAID 5 partition in Server 2008 with 4 RAID 5 disks. These disks are connected through a SATA expansion card that uses PCIe. This morning, I checked and they had finally finished synchronizing, and so I tried to do some speed tests. Copying off the disks started pretty much fine - speeds began at 125MB/s, then trailed down to about 70MB/s, which I found odd but not worrying. Writing TO the disks however is a completely different story. I attempted to copy some of my VM host ISOs onto the disks (~2-4 GB apiece) and this resulted in speeds of approximately 10MB/s. I tried copying both from a local disk (connected directly to the motherboard) and from another server ththe gigabit network and results were the same. I checked the performance monitor while transferring the files and the only thing that stuck out was that my memory hard faults shot up to 6,000 per minute (spiking around 200/s) by explorer.exe. The system is running 2GB of DDR667 ECC RAM and a quad-core 2.3GHz opteron. Is there anything I can do to fix this performance issue (buy more RAM? move the drives to a faster box?, etc) or am I just screwed so long as I stick to windows.

    Read the article

  • How long to install a new RAID 1 pair in linux using hardware RAID?

    - by Roger H
    Hi, I need to install a pair of 1Tb disks into a server that has a hardware RAID card. How long is it likely to take to configure the RAID controller - sticking the disks in is only a 5 minute job, but is there likely to be significant downtime while both disks mirror (even though they are both blank)? Am I looking at 10 minutes over all, or more like 2 hours for this to happen? Thanks

    Read the article

  • What the best way to recover from when your RAID H/W incorrectly thinks a disk is missing

    - by Software Monkey
    I have a Windows 7 system with an MSI motherboard (running the latest AMD BIOS) and two of my four disks (not the system boot disk) configured via the Mobo as RAID-1. After a normal system restart today, the RAID BIOS reports that one of the two drives has been disconnected or has failed. It's not really failed; via recovery tools I can verify that if I take the BIOS out of RAID mode. But I can find no way to re-add the second hard disk to the array and rebuild via the BIOS - the only option seems be to delete the array and recreate it, but I've done that once before and it blows away the disk. It's done this once before, however on a subsequent reboot after double-checking the drive cabling (but not changing anything) and it boot up fine. So I think the mobo RAID is a little bit flaky. At this point I would like to remove the RAID drivers, change to AHCI mode and switch over to using a Windows 7 dynamic mirror disk. But the RAID drivers seem somehow deeply bound into the Windows startup - I can't find anything like the good ol' safe-mode in Windows 7. If I boot from the Win 7 install disk in ACHI mode I can use recovery tools to log in to the Windows 7 installation, so the boot drive it seems fine with ACHI mode. Additionally, I can see all my other disks, run chkdsk on them and they seem to be fine. If I try to boot from the HDD in AHCI mode, it just reboots part way through, presumably because the RAID drivers load and conflict with the BIOS being set to AHCI. So: How do I strip the RAID drivers from my Win 7 installation? If I delete the RAID logical disk, will it really delete partitioning information, or is that just a poorly worded message when it says the data on the disk will be deleted? If I disconnect the 2 disks in a RAID array, then delete the logical disk array, and then reconnect and reboot still in RAID mode, will the disks simply revert to RAID single-disks like my other 2 and then maybe I can leave windows with RAID drivers by operate the disks as singles with 2 of them in a Windows dynamic disk mirrored setup? Does Windows 7 have anything like the Windows XP Repair Install, where it will reinstall the O/S binaries from CD, but leave apps and setup alone. I am really hoping I don't have to do a complete reinstall of Windows 7 - the last one, when I upgraded from XP, took me two days to get everything set up and installed.

    Read the article

  • Optimal Disk Setup for OLTP SQL Server

    - by Chris
    We have a high transaction (lots of reads and writes) database server (running SQL 2005) that is currently set up with a RAID 1 OS partition (C:) and a RAID 5 data/log/tempdb partition (D:). The C: has 2 drives and the D: has 4 drives. The server has around 300 databases ranging from 10MB to 2GB in size. I have been reading up on best practices for partioning the disks, but would like some opinions on our setup since we are so limited in the number of disks. It seems like RAID 10 is popular, but I dont think we could use it with only 6 total disks to work with. Thanks. Update I went with 3 RAID 1 Partitions (2 disks each) Partition 1: OS, TempDB, Backups Partition 2: Logs Partition 3: Data

    Read the article

  • How to recover ~1TB data from a bricked NAS?

    - by alastairs
    I bought an IcyBox NAS a little while back, and it recently died on me. I have physical access to the disks inside (1.5TB RAID 1 array), and the box was running a version of Linux. I now have the difficulty of retrieving the data from the disks. All I have available are 2 Windows machines, one of which has sufficient free space to hold the data from the NAS. What would be the quickest and easiest way to retrieve the data from the disks?

    Read the article

  • IBM BladeCenter S: Disk Configuration

    - by gravyface
    Have just the one storage bay right now (SAS 15K 600GB x 6) and have configured one storage pool in RAID 10 with 4 disks (and two global spares). For each blade, I've created a volume and mapped accordingly: Blade #1 400 GB Blade #2 200 GB Blade #3 100 GB Blade #4 100 GB When I boot up Blade 1 and enter into the UEFI Setup (F1) followed by the Adapters and UEFI Drivers LSI Logic Fusion MPT SAS Driver Utility, I see 4 disks: two are the on-board 73GB drives, the other two are 200GB each and assume I'm being presented with two logical disks from the volume I created and mapped to this blade. I was a bit surprised by this: I figured I would've been presented with one logical drive per volume, not two. I'm assuming I can just configure whatever RAID level I wish that supports two disks, but not really sure what the benefits/trade-offs here. Should I go with RAID 10 on top of RAID 10? RAID 0? Software RAID 0/1/10? Does it even matter? If this is "normal" to see two disks, then I'm going to likely just do some benchmarking and see if it makes a difference changing the RAID levels (my guess is no); if this is not normal, well, please let me know. :)

    Read the article

  • spontaneous hard disk password

    - by sc
    I had an HP proliant server go down recently. All of the sudden the sas controller (e200i) would not see any of the physical disks. New disks were detected just fine. I thought it was odd that all 6 disks would go down at one time so sent them to a data recovery firm to find out what happened. I'm being told that, somehow, all of the disks were spontaneously password protected. These are Hitachi 2.5" drives and I guess this is something of a known issue. The company has worked for a while to try and recover them, with no luck. Has anyone had experience with this? Any recommendations for how to recover the drives or a company that might have the expertise to do so?

    Read the article

  • Hard Disk recovery

    - by Shaihi
    I have 3 disks of the same type model and year of production. All the disks were used part of a generic solution of an IBM server solution. My problem is that all 3 disks suffered the same malfunction at the same exact time and are now dis-functional. I went to two different expert's laboratories and got the same answer: To recover the data they need another identical disk from which they can take spare parts. Can my case really be that clinical? Anyway, I am not sure if this question belongs to this forum, but I am looking to buy the following disk: IIBM ESERVER XSERIES IBM P/N 24P3707 IBM FRU 24P3708 146.8GB USCSI 10K RPM PART NOMBER 9V2005-027 I already bought a disk with the same part number, but the labs said that apparently I need a disk that was manufactured in the same factory. That means that all the numbers have to be exactly the same. If anybody know where I can purchase such a disk (the information on the lost disks is really important to me), please tell me the place.

    Read the article

  • Expanding raidz vdev

    - by Blubber
    I'm currently planning on installing FreeBSD 9 on my home server. The machine has 4x 1.5TB disks, and at some point, when HDD prices drop I'll be upgrading to something bigger, perhaps 3TB. The disks are connected to an IBM ServerRaid m1015 in IT mode, this card has room for up to eight disks. Now here is the problem, currently the 4x 1.5TB will be connected to the m1015. Then when prices drop I'll be adding something like 4x 3TB, also connected to the m1015. No problem yet, I can just run 2 raidz2 vdevs and put them in the same pool. But, at some point the 1.5TBs will start to break, or I will have to upgrade them when the pool runs out of space. So I started researching if it's possible to expand a raidz vdev, and I found several pages explaining the same procedure, like this on SF: How to upgrade a ZFS RAID-Z array to larger disks on OpenSolaris?. So I went a head and tried that in vmware, I installed FreeBSD 9 and created 6 virtual disks, 3 of 1GB each and 3 of 10GB each. After building a raidz vdev of the 1GBs I replaced them one by one with the 10GB, but the pool did not increase in size. Is this a limitation of the ZFS implementation in FreeBSD? Or am I just doing something wrong?

    Read the article

  • What IT tasks have you found in your career to be just painful

    - by Chopper3
    We always try to be clever and script everything that we find repetitive but not everything can be automated - what have you found in your career to be just a massive pain? I'll give you mine - building Netware version 2.xx on 5.25" disks with multiple NICs - this often took HOURS of swapping disks, pacing around, swapping disks, more pacing etc. Then finally it would hopefully work - if you'd not set the IRQs/DMAs right you had to start again, wow I loved version 3 which didn't need all that. What about you?

    Read the article

  • Do 7.2k SATA drives and a hardware raid controller always end with trouble?

    - by xelco52
    I'm reading the FreeNAS userguide and came across the statement: Note that hardware RAID configured as JBOD may still detach disks that do not respond in time; and as such may require TLER/CCTL/ERC-enabled disks to prevent drive dropouts. I'm using a '3Ware 9550SX-8LP RAID Controller' and see quite a few stories of people successfully running raid5 on 7.2k consumer SATA drives without issue. Are detached disks only a theoretical problem, or should I expect this to be a common occurrence?

    Read the article

  • "wrong fs type, bad option, bad superblock" error while mounting FAT Drives

    - by cshubhamrao
    I am unable to mount any fat32 or fat16 formatted usb disks under Ubuntu 13.10. The thing here to note is that it is happening only with fat formatted Disks. ntfs, ext formatted external usb disks work well (I tried formatting the same with ext4 and it worked) While mounting via nautilus: Error while mounting from terminal: root@shubham-pc:~# mount -t vfat /dev/sdc1 /media/shubham/n mount: wrong fs type, bad option, bad superblock on /dev/sdc1, missing codepage or helper program, or other error In some cases useful info is found in syslog - try dmesg | tail or so As suggested by the error: Output from dmesg | tail root@shubham-pc:~# dmesg | tail [ 3545.482598] scsi8 : usb-storage 1-1:1.0 [ 3546.481530] scsi 8:0:0:0: Direct-Access SanDisk Cruzer 1.26 PQ: 0 ANSI: 5 [ 3546.482373] sd 8:0:0:0: Attached scsi generic sg3 type 0 [ 3546.483758] sd 8:0:0:0: [sdc] 15633408 512-byte logical blocks: (8.00 GB/7.45 GiB) [ 3546.485254] sd 8:0:0:0: [sdc] Write Protect is off [ 3546.485262] sd 8:0:0:0: [sdc] Mode Sense: 43 00 00 00 [ 3546.488314] sd 8:0:0:0: [sdc] Write cache: disabled, read cache: enabled, doesn't support DPO or FUA [ 3546.499820] sdc: sdc1 [ 3546.503388] sd 8:0:0:0: [sdc] Attached SCSI removable disk [ 3547.273396] FAT-fs (sdc1): IO charset iso8859-1 not found Output from fsck.vfat: root@shubham-pc:~# fsck.vfat /dev/sdc1 dosfsck 3.0.16, 01 Mar 2013, FAT32, LFN /dev/sdc1: 1 files, 1/1949978 clusters All normal Tried re-creating the whole partition table and then formatting as fat32 but to no avail so the possibility of corrupted drive is ruled out. Tried the same with around 4 Disks or so and all have the same things

    Read the article

  • 12.04 grub unable to boot on /sde, upgrade-grub and boot-repair failed, please help

    - by VGR
    My problem is I've 4 disks in a raid array listed as sda, sdb... sdd and grub 2 refuses to boot on /sde (the 5th disk, standalone and containing a clean install of 12.04 64 bits). I tried all solutions but all fail. (live CD/USB with grub-setup, also tried repair-grub, and tried also in the "grub rescue" set prefix= etc). I also tried to deactivate the RAID array in the BIOS, but I'd rather not destroy it, and I didn't find a way to make the standalone disk as '/sda1' (this would satisfy grub). In the BIOS, the would-be /sda is the only bootable hard disk; it ends up as /sde and grubs complains. I've made repair-grub issue a pastebin. I always end up in grub-rescue and I'm stuck. I need Ubuntu to boot so that I can add the device array handler for my disks. I can't switch the disks and I can't disconnect the SATA RAID controller. I need: (a) a workaround so that grub starts on /sde; or (b) a way to change the order in which Ubuntu sees the disks, at boot time. I could then provide grub with a /sda1. Thanks a lot. up please thanks a lot it's not the same problem as booting ubuntu from raid. My RAID array serves only of data repository windows had no problem with this configuration

    Read the article

  • Cost Comparison Hard Disk Drive to Solid State Drive on Price per Gigabyte - dispelling a myth!

    - by tonyrogerson
    It is often said that Hard Disk Drive storage is significantly cheaper per GiByte than Solid State Devices – this is wholly inaccurate within the database space. People need to look at the cost of the complete solution and not just a single component part in isolation to what is really required to meet the business requirement. Buying a single Hitachi Ultrastar 600GB 3.5” SAS 15Krpm hard disk drive will cost approximately £239.60 (http://scan.co.uk, 22nd March 2012) compared to an OCZ 600GB Z-Drive R4 CM84 PCIe costing £2,316.54 (http://scan.co.uk, 22nd March 2012); I’ve not included FusionIO ioDrive because there is no public pricing available for it – something I never understand and personally when companies do this I immediately think what are they hiding, luckily in FusionIO’s case the product is proven though is expensive compared to OCZ enterprise offerings. On the face of it the single 15Krpm hard disk has a price per GB of £0.39, the SSD £3.86; this is what you will see in the press and this is what sales people will use in comparing the two technologies – do not be fooled by this bullshit people! What is the requirement? The requirement is the database will have a static size of 400GB kept static through archiving so growth and trim will balance the database size, the client requires resilience, there will be several hundred call centre staff querying the database where queries will read a small amount of data but there will be no hot spot in the data so the randomness will come across the entire 400GB of the database, estimates predict that the IOps required will be approximately 4,000IOps at peak times, because it’s a call centre system the IO latency is important and must remain below 5ms per IO. The balance between read and write is 70% read, 30% write. The requirement is now defined and we have three of the most important pieces of the puzzle – space required, estimated IOps and maximum latency per IO. Something to consider with regard SQL Server; write activity requires synchronous IO to the storage media specifically the transaction log; that means the write thread will wait until the IO is completed and hardened off until the thread can continue execution, the requirement has stated that 30% of the system activity will be write so we can expect a high amount of synchronous activity. The hardware solution needs to be defined; two possible solutions: hard disk or solid state based; the real question now is how many hard disks are required to achieve the IO throughput, the latency and resilience, ditto for the solid state. Hard Drive solution On a test on an HP DL380, P410i controller using IOMeter against a single 15Krpm 146GB SAS drive, the throughput given on a transfer size of 8KiB against a 40GiB file on a freshly formatted disk where the partition is the only partition on the disk thus the 40GiB file is on the outer edge of the drive so more sectors can be read before head movement is required: For 100% sequential IO at a queue depth of 16 with 8 worker threads 43,537 IOps at an average latency of 2.93ms (340 MiB/s), for 100% random IO at the same queue depth and worker threads 3,733 IOps at an average latency of 34.06ms (34 MiB/s). The same test was done on the same disk but the test file was 130GiB: For 100% sequential IO at a queue depth of 16 with 8 worker threads 43,537 IOps at an average latency of 2.93ms (340 MiB/s), for 100% random IO at the same queue depth and worker threads 528 IOps at an average latency of 217.49ms (4 MiB/s). From the result it is clear random performance gets worse as the disk fills up – I’m currently writing an article on short stroking which will cover this in detail. Given the work load is random in nature looking at the random performance of the single drive when only 40 GiB of the 146 GB is used gives near the IOps required but the latency is way out. Luckily I have tested 6 x 15Krpm 146GB SAS 15Krpm drives in a RAID 0 using the same test methodology, for the same test above on a 130 GiB for each drive added the performance boost is near linear, for each drive added throughput goes up by 5 MiB/sec, IOps by 700 IOps and latency reducing nearly 50% per drive added (172 ms, 94 ms, 65 ms, 47 ms, 37 ms, 30 ms). This is because the same 130GiB is spread out more as you add drives 130 / 1, 130 / 2, 130 / 3 etc. so implicit short stroking is occurring because there is less file on each drive so less head movement required. The best latency is still 30 ms but we have the IOps required now, but that’s on a 130GiB file and not the 400GiB we need. Some reality check here: a) the drive randomness is more likely to be 50/50 and not a full 100% but the above has highlighted the effect randomness has on the drive and the more a drive fills with data the worse the effect. For argument sake let us assume that for the given workload we need 8 disks to do the job, for resilience reasons we will need 16 because we need to RAID 1+0 them in order to get the throughput and the resilience, RAID 5 would degrade performance. Cost for hard drives: 16 x £239.60 = £3,833.60 For the hard drives we will need disk controllers and a separate external disk array because the likelihood is that the server itself won’t take the drives, a quick spec off DELL for a PowerVault MD1220 which gives the dual pathing with 16 disks 146GB 15Krpm 2.5” disks is priced at £7,438.00, note its probably more once we had two controller cards to sit in the server in, racking etc. Minimum cost taking the DELL quote as an example is therefore: {Cost of Hardware} / {Storage Required} £7,438.60 / 400 = £18.595 per GB £18.59 per GiB is a far cry from the £0.39 we had been told by the salesman and the myth. Yes, the storage array is composed of 16 x 146 disks in RAID 10 (therefore 8 usable) giving an effective usable storage availability of 1168GB but the actual storage requirement is only 400 and the extra disks have had to be purchased to get the  IOps up. Solid State Drive solution A single card significantly exceeds the IOps and latency required, for resilience two will be required. ( £2,316.54 * 2 ) / 400 = £11.58 per GB With the SSD solution only two PCIe sockets are required, no external disk units, no additional controllers, no redundant controllers etc. Conclusion I hope by showing you an example that the myth that hard disk drives are cheaper per GiB than Solid State has now been dispelled - £11.58 per GB for SSD compared to £18.59 for Hard Disk. I’ve not even touched on the running costs, compare the costs of running 18 hard disks, that’s a lot of heat and power compared to two PCIe cards!Just a quick note: I've left a fair amount of information out due to this being a blog! If in doubt, email me :)I'll also deal with the myth that SSD's wear out at a later date as well - that's just way over done still, yes, 5 years ago, but now - no.

    Read the article

  • How to add another OS entry in Wubi grub

    - by Amey Jah
    I am trying to install another linux distro besides ubuntu. However, I want to retain my existing windows based loader. Currently, as per my knowledge, MsDos loads grub which then loads Ubuntu (with loop back trick). Now, I have a new linux distro installed on /dev/sda8 (/boot for new distro) where as /root for that OS is installed on /dev/sda9. I tried following steps 1. Add entry into 40_custom of ubuntu grub 2. update grub But upon booting via that entry, it is not able to load the new OS and shows me blank screen. What could be the problem? Additional data: grub.cfg file of ubuntu menuentry 'Ubuntu' --class ubuntu --class gnu-linux --class gnu --class os $menuentry_id_option 'gnulinux-simple-fc296be2-8c59-4f21-a3f8-47c38cd0d537' { gfxmode $linux_gfx_mode insmod gzio insmod ntfs set root='hd0,msdos5' if [ x$feature_platform_search_hint = xy ]; then search --no-floppy --fs-uuid --set=root --hint-bios=hd0,msdos5 --hint-efi=hd0,msdos5 --hint-baremetal=ahci0,msdos5 01CD7BB998DB0870 else search --no-floppy --fs-uuid --set=root 01CD7BB998DB0870 fi loopback loop0 /ubuntu/disks/root.disk set root=(loop0) linux /boot/vmlinuz-3.5.0-19-generic root=UUID=01CD7BB998DB0870 loop=/ubuntu/disks/root.disk ro quiet splash $vt_handoff initrd /boot/initrd.img-3.5.0-19-generic } submenu 'Advanced options for Ubuntu' $menuentry_id_option 'gnulinux-advanced-fc296be2-8c59-4f21-a3f8-47c38cd0d537' { menuentry 'Ubuntu, with Linux 3.5.0-19-generic' --class ubuntu --class gnu-linux --class gnu --class os $menuentry_id_option 'gnulinux-3.5.0-19-generic-advanced-fc296be2-8c59-4f21-a3f8-47c38cd0d537' { gfxmode $linux_gfx_mode insmod gzio insmod ntfs set root='hd0,msdos5' if [ x$feature_platform_search_hint = xy ]; then search --no-floppy --fs-uuid --set=root --hint-bios=hd0,msdos5 --hint-efi=hd0,msdos5 --hint-baremetal=ahci0,msdos5 01CD7BB998DB0870 else search --no-floppy --fs-uuid --set=root 01CD7BB998DB0870 fi loopback loop0 /ubuntu/disks/root.disk set root=(loop0) echo 'Loading Linux 3.5.0-19-generic ...' linux /boot/vmlinuz-3.5.0-19-generic root=UUID=01CD7BB998DB0870 loop=/ubuntu/disks/root.disk ro quiet splash $vt_handoff echo 'Loading initial ramdisk ...' initrd /boot/initrd.img-3.5.0-19-generic } menuentry 'Ubuntu, with Linux 3.5.0-19-generic (recovery mode)' --class ubuntu --class gnu-linux --class gnu --class os $menuentry_id_option 'gnulinux-3.5.0-19-generic-recovery-fc296be2-8c59-4f21-a3f8-47c38cd0d537' { insmod gzio insmod ntfs set root='hd0,msdos5' if [ x$feature_platform_search_hint = xy ]; then search --no-floppy --fs-uuid --set=root --hint-bios=hd0,msdos5 --hint-efi=hd0,msdos5 --hint-baremetal=ahci0,msdos5 01CD7BB998DB0870 else search --no-floppy --fs-uuid --set=root 01CD7BB998DB0870 fi loopback loop0 /ubuntu/disks/root.disk set root=(loop0) echo 'Loading Linux 3.5.0-19-generic ...' linux /boot/vmlinuz-3.5.0-19-generic root=UUID=01CD7BB998DB0870 loop=/ubuntu/disks/root.disk ro recovery nomodeset echo 'Loading initial ramdisk ...' initrd /boot/initrd.img-3.5.0-19-generic } } ### END /etc/grub.d/10_lupin ### menuentry 'Linux, with Linux core repo kernel' --class arch --class gnu-linux --class gnu --class os $menuentry_id_option 'gnulinux-core repo kernel-true-0f490b6c-e92d-42f0-88e1-0bd3c0d27641'{ load_video set gfxpayload=keep insmod gzio insmod part_msdos insmod ext2 set root='hd0,msdos8' if [ x$feature_platform_search_hint = xy ]; then search --no-floppy --fs-uuid --set=root --hint-bios=hd0,msdos8 --hint-efi=hd0,msdos8 --hint-baremetal=ahci0,msdos8 0f490b6c-e92d-42f0-88e1-0bd3c0d27641 else search --no-floppy --fs-uuid --set=root 0f490b6c-e92d-42f0-88e1-0bd3c0d27641 fi echo 'Loading Linux core repo kernel ...' linux /boot/vmlinuz-linux root=UUID=0f490b6c-e92d-42f0-88e1-0bd3c0d27641 ro quiet echo 'Loading initial ramdisk ...' initrd /boot/initramfs-linux.img } menuentry 'Linux, with Linux core repo kernel (Fallback initramfs)' --class arch --class gnu-linux --class gnu --class os $menuentry_id_option 'gnulinux-core repo kernel-fallback-0f490b6c-e92d-42f0-88e1-0bd3c0d27641' { load_video set gfxpayload=keep insmod gzio insmod part_msdos insmod ext2 set root='hd0,msdos8' if [ x$feature_platform_search_hint = xy ]; then search --no-floppy --fs-uuid --set=root --hint-bios=hd0,msdos8 --hint-efi=hd0,msdos8 --hint-baremetal=ahci0,msdos8 0f490b6c-e92d-42f0-88e1-0bd3c0d27641 else search --no-floppy --fs-uuid --set=root 0f490b6c-e92d-42f0-88e1-0bd3c0d27641 fi echo 'Loading Linux core repo kernel ...' linux /boot/vmlinuz-linux root=UUID=0f490b6c-e92d-42f0-88e1-0bd3c0d27641 ro quiet echo 'Loading initial ramdisk ...' initrd /boot/initramfs-linux-fallback.img } lsblk NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT sda 8:0 0 931.5G 0 disk +-sda1 8:1 0 39.2M 0 part +-sda2 8:2 0 19.8G 0 part +-sda3 8:3 0 205.1G 0 part +-sda4 8:4 0 1K 0 part +-sda5 8:5 0 333.7G 0 part /host +-sda6 8:6 0 233.4G 0 part +-sda7 8:7 0 100.4G 0 part +-sda8 8:8 0 100M 0 part +-sda9 8:9 0 14.7G 0 part +-sda10 8:10 0 21.4G 0 part +-sda11 8:11 0 3G 0 part sr0 11:0 1 1024M 0 rom loop0 7:0 0 29G 0 loop / blkid /dev/loop0: UUID="fc296be2-8c59-4f21-a3f8-47c38cd0d537" TYPE="ext4" /dev/sda1: SEC_TYPE="msdos" LABEL="DellUtility" UUID="5450-4444" TYPE="vfat" /dev/sda2: LABEL="RECOVERY" UUID="78C4FAC1C4FA80A4" TYPE="ntfs" /dev/sda3: LABEL="OS" UUID="DACEFCF1CEFCC6B3" TYPE="ntfs" /dev/sda5: UUID="01CD7BB998DB0870" TYPE="ntfs" /dev/sda6: UUID="01CD7BB99CA3F750" TYPE="ntfs" /dev/sda7: LABEL="Windows 8" UUID="01CDBFB52F925F40" TYPE="ntfs" /dev/sda8: UUID="cdbb5770-d29c-401d-850d-ee30a048ca5e" TYPE="ext2" /dev/sda9: UUID="0f490b6c-e92d-42f0-88e1-0bd3c0d27641" TYPE="ext2" /dev/sda10: UUID="2e7682e5-8917-4edc-9bf9-044fea2ad738" TYPE="ext2" /dev/sda11: UUID="6081da70-d622-42b9-b489-309f922b284e" TYPE="swap Any help is appreciated. Please let me know if you need any extra data.

    Read the article

< Previous Page | 5 6 7 8 9 10 11 12 13 14 15 16  | Next Page >