  • How to troubleshoot a hardware problem on linux?

    - by Jack
    Just to note I am not having a problem at the moment, but have had previously so it sparked my curiosity... When a computer locks up suddenly to so caps lock flashes incessantly and the only possibility to restart....how do you troubleshoot what is causing it? On Windows there would be some errors in the event log...on Linux it seems there is no opportunity for anything to be written to the log, making it hard to troubleshoot... In this case, how would you troubleshoot the problem through linux?

    Read the article

  • hardware: delay and distinct 'click' before hard drive access

    - by matt lohkamp
    I have a windows 7 box stashed away in my closet, containing (among other things) 2 big HDDs linked together as a mirrored volume - basically a super lazy NAS / media server. I've noticed that when that drive is accessed (whether locally, on the machine itself, or remotely, from another computer, or my xbox, for example) there's a noticeable pause, and then from the computer itself, a 'click!' noise, after which the drive is accessed; e.g. open \\computername\shared\, wait 2 seconds, hear 'click!' and then see files appear in windows explorer. Any ideas? Otherwise the drive preforms normally - is it a windows thing? a HDD-about-to-die thing? Or a "yeah that always happens, you've just never noticed it before" thing?

    Read the article

  • Choosing hardware for Flash Media Server

    - by minaev
    Having read the answers in this discussion, I still would like to come up with the same question: What should I buy to run Flash Media Interactive Server 3.5? I just have slightly different boundary conditions. We plan to serve video to ca. 1,000 users simultaneously. It will be live stream, so the server will receive the stream in HD (1280x720), cache it, reformat to various other resolutions and send it to users. OS of choice is Linux, but if you say it should MS-DOS, so it will be... What would be a decent server for this task?

    Read the article

  • Suppliers for revision-controlled hardware, long-life motherboards?

    - by jacobsee
    Has anyone had good experience with suppliers of industrial computers, specifically 'long-life, revision-controlled' motherboards? I'm found a couple of likely candidates including ITOX, BCM, and DuroPC but haven't been able to find much in the way of independent review. I'm currently using off the shelf motherboards for an industrial data-acquisition system and am trying to eliminate the problem of rapid turnover/obsolescence of motherboards.

    Read the article

  • Minecraft server hosting hardware specifications [on hold]

    - by Andrew Wright
    I am planning on purchasing a server to rent off Minecraft game servers, largely to friends. I am planning on purchasing a 128GB RAM server to save on colocation costs (as I am likely to need more than 32GB and would have to rent 2U of space...) I am hoping for some advice about the processing power needed to deal with this level of RAM. The servers will be run in a shared environment on linux in a VM to make backups easier. The server I have in mind is dual CPU. I have been considering at the low end dual Xeon E5-2609V2 Quad-Core 2.5Ghz, and at the high end dual Xeon E5-2650V2 Eight-Core 2.6Ghz. The difference between these is 6.4 GT/s and 8 GT/s and £3000 for the lower spec server, £4300 for the higher spec. I was hoping I could get advice about whether it is worth paying for the extra/higher speed processor or if I would be wasting my money? Thank you for any help - I appreciate that this is not directly related to professional system administration.

    Read the article

  • Notebook display problem (multiplication)

    - by SubniC
    Hi, I'm having some troubles with the display of a LG E500 notebook. The thing is that without any known reason the display starts to show the screen divided in eigth parts and each part show the display image as if I had a matrix of eigth displays :) I thought it could be some kind of refresh rate problem or driver related, but it is happening at boot-up as well and the BIOS. I got the computer completely unassambled yesterday and I check all the wires and connectors looking for something broken or unconected, but without luck... You can see a picture here of the problem (sorry for the low quality, but I think it illustrate the problem. EDIT 1: I uploaded a new pictrue, here you cans ee the problem better :) There are three horizontal lines that you can see just between the windows. You can see the grey line at the first moment you turn on the computer and the after the duplicated screens show up just like if they where arranged over a grid (over the horizontal lines...) I hope it makes any sense. Do you know what could be happening? or can you tell me what would you do? Thank you very much for your help.

    Read the article

  • Power outage during disk wipe. What do I do now?

    - by Mark Trexler
    I was using Roadkil Diskwipe on an external hard drive and the power went out. I had removed it from any outlet connection by the time power was restored to prevent power-spike damage (it's on a surge protector, but I didn't want to rely on that). My question is, where do I go from here? Obviously I don't care about preserving any data currently on it, I just want to make sure the drive itself is not terminally damaged. I'm running chkdsk (full), but I don't know if that's the correct step to assessing any damage. If it makes any difference, the hard drive was unallocated at the time of the outage, as Diskwipe requires that for it to run. Also, could something like this cause latent problems with the drive itself (i.e. serious issues that I won't be aware of when testing it now). I'd appreciate any program recommendations if chkdsk is not the most appropriate diagnostic route. Thank you.

    Read the article

  • Get Hardware Information for HWs that is not installed

    - by Isaac
    I am pretty sure how to retrieve hardware information with WMI classes. but WMIs have a big limitation: They Just can get information for installed hardwares. I need to retrieve information about CPU (model,speed,etc..),Video Card, Sound Card, USB Ports, etc. I found a really good software (HWiNFO) that can do this even the drivers for hardware parts is not installed. It seems that HWiNFO uses a internal database to give a name for each hardware part. So is there any free library/DLL/component that can do this in Windows XP or higher Note: Although HWiNFO SDK seems good, it's not free. So it doesn't exist! ;) I need a free library.

    Read the article

  • Computer turns itself on after any off mode

    - by Patrick
    Whenever I shut down my computer, or put it in sleep/hybernate, it turns on after two seconds. It doesn't post, it just powers on and then idles. To actually turn it off, I switch off the psu. The problem is now, whenever I switch the psu on and try to boot, it doesn't always turn on. It takes a good amount of flicking the psu switch on and off before the motherboard lights up. So far I've determined the things its not: its not caused by the mouse or network waking up the computer. I've been able to go into hybernate for the past year. And all "wake on X" settings in the bios are diabled. its not a scheduled task waking up the computer at a given hour, it occurs every single time its not due to an upgrade or new installation, since I haven't done either in a very long time I'm sure its a hardware issue. So I'd like to know, is my psu dead, or the motherboard? The psu is an Antec Earthwatts 600w, the motherboard is an Asus P5Q-E, both one year old.

    Read the article

  • Is this possible to re-duplicate the hardware signal on Linux?

    - by Ted Wong
    Since that every things is a file on the UNIX system. If I have a hardware, for example, a mouse, move from left corner to right corner, it should produce some kinds of file to communicate with the system. So, if my assumption is correct, is this possible to do following things: Capture the raw data, which is about moving mouse cursor from left corner to right corner? Reduplicate the raw data, using a program, same producing speed, and data, in order to "redo" moving mouse cursor from left corner to right corner

    Read the article

  • How do I toggle the wifi hardware switch for a Dell XPS 17 L702X?

    - by Sparhawk
    Every now and then, I disable my wireless via the menu icon in Ubuntu. Then, when I try to enable the wifi, it tells me that "wireless is disabled" or "wireless is disabled by hardware switch". There is a red icon on the F2 key that looks like a wireless icon, and in Windows, pressing the (red) Fn key and F2 toggles the wifi. This does not work in Ubuntu, leaving me no clear way to turn wifi back on. How can I restart wifi in Ubuntu?

    Read the article

  • My PC suddenly doesn't detect the primary drive (SSD)

    - by smoth190
    My computer has been working fine for months, and it worked today, but tonight I went to start it up to find that my OCZ Vertex 2 isn't being found. When I turn on my computer, the loading screen gets stuck at "Detecting IDE drives...". After a while, it keeps going and lists the drives it finds. The first one in the list should be my Vertex 2, but it just says "None". The computer proceeds to get stuck on "Loading operating system...", which is understandable because the drive with the OS is "gone". My first thought was drive failure, but every time drives have crashed on me, they're still detected--they just don't work. This drive is an SSD, it's pretty new, and I had no problems beforehand. I find it hard to believe it failed. I'm sure it's possible, but I hope this isn't the case. There has been nothing strange going on at all with my PC, it's been running perfect until now. I was just about to do my monthly dskchk and defrag today. I popped in my Windows 7 Home Premium disk and booted from it. When I launched the repair tool, it didn't list any operating systems (because the drive is 100% missing...). When I've had disks crash before, it still listed the OS, you just couldn't do anything with it. I tried to restore from an image, but I don't have any of those, either. I opened the command console and listed the drivers with wmic logicaldisk get name. Only C: and D: came up. C: was my 1TB storage driver (luckily, all my stuff is here--only the OS is on the SSD!) and D: was the disk driver. So I still had an MIA drive... The SSD didn't come with any driver disks, so I can't install drivers. If there's a way to do this from a CD I can burn with my other PC, please let me know. What the heck do I do? Although only the OS is on my SSD, a new SSD is expensive. I'll probably also have to buy a new copy of Windows (an upgrade would be nice, though...) because I've found it eats my registration key when my PC crashes (and my thousands of dollars of Adobe programs, I'll be on the phone with tech support for a week to get those keys back). And I'll lose my registry, all my settings, all sorts of other stuff that I'll spend weeks restoring. My computer is a pain in the butt to take out and open up, so if I can't fix it, I'll try fiddling with the plug or putting it into a new computer, but not right now. Any help is greatly appreciated! The day when they make crash-less drives will be the day I live without worry.

    Read the article

  • HFT strategy coding on hardware

    - by bsobaid
    Hardware accelaration and embedded programming has mostly been used so far to parse datafeed and/or to route orders to exchange. Have there been attempts to write simpler HFT strategies such as equity market-making in hardware? Have they been successful? Which companies are doing this and what kind of programming model is used?

    Read the article

  • Sun Ray Hardware Last Order Dates & Extension of Premier Support for Desktop Virtualization Software

    - by Adam Hawley
    In light of the recent announcement  to end new feature development for Oracle Virtual Desktop Infrastructure Software (VDI), Oracle Sun Ray Software (SRS), Oracle Virtual Desktop Client (OVDC) Software, and Oracle Sun Ray Client hardware (3, 3i, and 3 Plus), there have been questions and concerns regarding what this means in terms of customers with new or existing deployments.  The following updates clarify some of these commonly asked questions. Extension of Premier Support for Software Though there will be no new feature additions to these products, customers will have access to maintenance update releases for Oracle Virtual Desktop Infrastructure and Sun Ray Software, including Oracle Virtual Desktop Client and Sun Ray Operating Software (SROS) until Premier Support Ends.  To ensure that customer investments for these products are protected, Oracle  Premier Support for these products has been extended by 3 years to following dates: Sun Ray Software - November 2017 Oracle Virtual Desktop Infrastructure - March 2017 Note that OVDC support is also extended to the above dates since OVDC is licensed by default as part the SRS and VDI products.   As a reminder, this only affects the products listed above.  Oracle Secure Global Desktop and Oracle VM VirtualBox will continue to be enhanced with new features from time-to-time and, as a result, they are not affected by the changes detailed in this message. The extension of support means that customers under a support contract will still be able to file service requests through Oracle Support, and Oracle will continue to provide the utmost level of support to our customers as expected,  until the published Premier Support end date.  Following the end of Premier Support, Sustaining Support remains an 'indefinite' period of time.   Sun Ray 3 Series Clients - Last Order Dates For Sun Ray Client hardware, customers can continue to purchase Sun Ray Client devices until the following last order dates: Product Marketing Part Number Last Order Date Last Ship Date Sun Ray 3 Plus TC3-P0Z-00, TC3-PTZ-00 (TAA) September 13, 2013 February 28, 2014 Sun Ray 3 Client TC3-00Z-00 February 28, 2014 August 31, 2014 Sun Ray 3i Client TC3-I0Z-00 February 28, 2014 August 31, 2014 Payflex Smart Cards X1403A-N, X1404A-N February 28, 2014 August 31, 2014 Note the difference in the Last Order Date for the Sun Ray 3 Plus (September 13, 2013) compared to the other products that have a Last Order Date of February 28, 2014. The rapidly approaching date for Sun Ray 3 Plus is due to a supplier phasing-out production of a key component of the 3 Plus.   Given September 13 is unfortunately quite soon, we strongly encourage you to place your last time buy as soon as possible to maximize Oracle's ability fulfill your order. Keep in mind you can schedule shipments to be delivered as late as the end of February 2014, but the last day to order is September 13, 2013. Customers wishing to purchase other models - Sun Ray 3 Clients and/or Sun Ray 3i Clients - have additional time (until February 28, 2014) to assess their needs and to allow fulfillment of last time orders.  Please note that availability of supply cannot be absolutely guaranteed up to the last order dates and we strongly recommend placing last time buys as early as possible.  Warranty replacements for Sun Ray Client hardware for customers covered by Oracle Hardware Systems Support contracts will be available beyond last order dates, per Oracle's policy found on Oracle.com here.  Per that policy, Oracle intends to provide replacement hardware for up to 5 years beyond the last ship date, but hardware may not be available beyond the 5 year period after the last ship date for reasons beyond Oracle's control. In any case, by design, Sun Ray Clients have an extremely long lifespan  and mean time between failures (MTBF) - much longer than PCs, and over the years we have continued to see first- and second generations of Sun Rays still in daily use.  This is no different for the Sun Ray 3, 3i, and 3 Plus.   Because of this, and in addition to Oracle's continued support for SRS, VDI, and SROS, Sun Ray and Oracle VDI deployments can continue to expand and exist as a viable solution for some time in the future. Continued Availability of Product Licenses and Support Oracle will continue to offer all existing software licenses, and software and hardware support including: Product licenses and Premier Support for Sun Ray Software and Oracle Virtual Desktop Infrastructure Premier Support for Operating Systems (for Sun Ray Operating Software maintenance upgrades/support)  Premier Support for Systems (for Sun Ray Operating Software maintenance upgrades/support and hardware warranty) Support renewals For More Information For more information, please refer to the following documents for specific dates and policies associated with the support of these products: Document 1478170.1 - Oracle Desktop Virtualization Software and Hardware Lifetime Support Schedule Document 1450710.1 - Sun Ray Client Hardware Lifetime schedule Document 1568808.1 - Document Support Policies for Discontinued Oracle Virtual Desktop Infrastructure, Sun Ray Software and Hardware and Oracle Virtual Desktop Client Development For Sales Orders and Questions Please contact your Oracle Sales Representative or Saurabh Vijay ([email protected])

    Read the article

  • Bad disks in ancient server

    - by Joel Coel
    I have a 1998-era Netware 3.12 server that runs everything on our campus: general ledger, purchasing, payroll, student information, grades, you name it. The server has an Adaptec RAID controller with two volumes: RAID 1, 2 17GB scsi disks, Seagate ST318417W RAID 5, 3 4GB scsi disks, 2 Seagate ST34573W and 1 ST34572W. We are currently in the early stages of a project to replace this system, but you don't just jump into a new system like that and so I need to keep this server running until at least November 2011. This week we had not one but two hard drives fail. Thankfully they are from different volumes and we're able to keep running for the moment, but given the close nature of these failures I have serious doubts that I'll be able to avoid catastrophic failure from this server through the November target as is without restoring the RAID redundancy — it'll only take one more drive failure anywhere and I'm completely hosed. We are fortunate enough to have exact match "spares" lying around for both drives, but the spares are in unknown condition. I tried swapping just them in, but the RAID controller isn't smart enough to handle this and it renders the system unbootable. As for the RAID controller itself, there is utility I can get into during POST via a Ctrl-A shortcut, but I can't do much useful from there. To actually manage volumes I must first boot in to Netware, at which point I can use CI/O Array Management Software Version 2.0 to actually look at volume information. I suspect that the normal way to manage things is to boot from a special floppy with the controller software on it, but that floppy is long gone. Going through the options in the RAID software, I think the only supported way to replace a disk in an existing RAID volume is to physically add the disk, boot up and configure it as a "spare" for a volume, force the volume to use the spare to replace an existing down disk (and at this point I'm only guessing) so that the down disk becomes the spare, repair the volume, remove the spare from the volume, and then shut down and remove the disk. Then start all over for the other failed disk. All this amounts to a lot of downtime, assuming I can even make it work and that my spares are any good. As for finding reliable spares, I have no clue where to even begin looking to find a new 4GB scsi drive, or even which exact scsi system I'm looking for, as it's gone through a few different iterations over time. Another option is to migrate this to a virtual machine (hyper-v), but all previous attempts we've made in this area have failed to get very far. When this machine was installed I was just graduating from high school, and so it requires lower level knowledge of netware and dos than I ever developed, or if I did have since forgotten (I'm not exactly a dos neophyte, either). Part of my problem is this is a high-use server, and taking it down for a few days to figure things out isn't gonna fly very well. As for the question, I'm looking for anything that might be helpful in this situation: a recommendation on a place to find good spares from this era, personal experience repairing RAID volumes using a similar controller or building a hyper-v vm from an old netware server, a line on a floppy with better software for the RAID controller, recommendation on a good Novell consultant in Nebraska that would be able to put things right, a whole other option I haven't considered yet, etc. Update: For backups, we have good (recently verified via restore) backups of the data only -- nothing for the software that actually runs things. Update 2: Just a progress report that I currently have a working Netware 3.12 install in VMWare Virtual Server 2.0, thanks largely to the guide I found here: http://cerbulescubogdan.blogspot.com/2010/11/novell-netware-312-on-vmware.html The next steps are preparing empty netware volumes to match the additional volumes on my existing server, taking a dump of everything on the C:\ drive and netware volumes on my existing server, and figuring out from that information what modules need added to netware, installing my licenses (we do still have that disk, if it's any good), and moving data over. I have approval to bring the server down for a week after the first of the year (sadly not before), so, aside from creating empty volumes, the rest of the work will have to wait until then. Final Update (Jan 5, 2011): I was able to get spares working in both raid arrays without data loss this week. Both are now listed by the controller as "FAULT TOLLERANT" (yay!). I was also able to build on the progress from my last update and now have a functional "spare" server in VMWare Server 2.0. The spare can run and use our erp software, but I can't put it into production because I can't (yet) print from that box (and I have no idea why). Even so, this VM will do in a pinch if I have no other choice, and between it and the repaired RAID arrays I'm comfortable pushing on until I can junk the machine in November.

    Read the article

  • Problems with the colors on my screen. How can I check if it's a hardware problem?

    - by Ingo Gerth
    On my EEE PC netbook some colors are not displayed properly. Specifically, dark gradients such as in the window title do not look very smooth, but rather look like a sequence of a couple of different colors. This is especially visible when opening a menu, for example the "File" menu in Firefox. As you know this one is black, and it looks terrible on my screen. It is not just black, but the colors look really graded and far from a smooth gradient or anything. Now I am wondering: Is this a hardware or software issue? And how can I check this? If it should be a fixable problem I think it would be worth another question. Note that I am using Natty. If my problem description is not good enough I can try to take a photo.

    Read the article

  • Reliable way of generating unique hardware ID

    - by mr.b
    Question: what's the best way to accomplish following. I have to come up with unique ID for each networked client, such that: it (ID) should persist once client software is installed on target computer, and should continue to persist if software is re-installed on same computer and same OS installment, it should not change if hardware configuration is modified in most ways (except changing the motherboard) When hard drive with client software installed is cloned to another computer with identical hardware configuration (or, as similar as possible), client software should be aware of that change. A little bit of explanation and some back-story: This question is basically age old question that also touches topic of software copy-protection, as some of mechanisms used in that area are mentioned here. I should be clear at this point that I'm not looking for a copy-protection scheme. Please, read on. :) I'm working on a client-server software that is supposed to work in local network. One of problems I have to solve is to identify each unique client in network (not so much of a problem), so that I can apply certain attributes to every specific client, retain and enforce those attributes during deployment lifetime of a specific client. While I was looking for a solution, I was aware of following: Windows activation system uses some kind of heavy fingerprinting mechanism, that is extremely sensitive to hardware modifications, Disk imaging software copies along all Volume IDs (tied to each partition when formatted), and custom, uniquely generated IDs during installation process, during first run, or in any other way, that is strictly software in its nature, and stored in registry or on hard drive, so it's very easy to confuse two Obvious choice for this kind of problem would be to find out BIOS identifiers (not 100% sure if this is unique through identical motherboard models, though), as that's the only thing I can rely on, that isn't duplicated, transferred by cloning, and that can't be changed (at least not by using some user-space program). Everything else fails as either being not reliable (MAC cloning, anyone?), or too demanding (in terms that it's too sensitive to configuration changes). Am I missing something obvious here? Sub-question that I'd like to ask is, am I doing it correctly, architecture-wise? Perhaps there is a better tool for task that I have to accomplish... Another approach I had in mind is something similar to handshake mechanism, where server maintains internal lookup table of connected client IDs (which can be even completely software-based and non-unique at any given moment), and tells client to come up with different ID during handshake, if duplicate ID is provided upon connection. That approach, unfortunately, doesn't play nicely with one of requirements to tie attributes to specific client during lifetime.

    Read the article

  • What is a hardware-id?

    - by Rob
    Some forums that I regularly visit sell premium programs, and to prevent them from being leaked they use hardware-id authentication. That is, first they send you a program to run to grab your HWID, you tell them your HWID, they store it in a database, then they send you the actual program. If your HWID isn't in the database, the program won't run. So what is Hardware-ID, and how is it generated? Why is it that my HWID is different depending on the programmer that sends me a HWID-grabber?

    Read the article

  • Simple hardware RNG

    - by roygbiv
    I made a tongue-in-cheek comment to this question about making a hardware RNG. Does anyone know of any simple plans or can anyone descibe a simple hardware based RNG and the software to drive it? Go to Radio Shack. Buy a diode, an NTR resistor, a capacitor and serial cable. Cut off the end of the serial cable that does not fit on your computer. Solder the diode and resistor in series between pins DTR and DSR of the cable. Solder the capacitor between DSR and TXD pins. Write a small C program to do the following: Set DTR to 1. Start Timer. Monitor DSR until it goes to 1. Stop Timer. Calculate resistance from elapsed time. Retreive serveral bits from that value to use as part of random number. Repeat until enough bits have accumulated.

    Read the article

  • Developer oriented hardware benchmarks?

    - by Promit
    Perhaps I'm looking in the wrong places, but every hardware benchmark I've found, for nearly any component, is oriented towards gamers and/or workstations (video editing etc). Is there anyone doing benchmarks that are relevant to software developers? For example, take SSDs. I don't care how fast Crysis loads off an SSD -- that is completely worthless information. What I want to know is, which drive yields the quickest build times? What about Intellisense and refactoring operations? What RAID configuration has the biggest benefit? I could probably come up with more examples, but you get the point. Long story short, where are the benchmarks that tell me which hardware will be most effective in helping me be a productive software developer?

    Read the article

  • Computer starts, POSTs normal, no video

    - by Annath
    So, I recently tried to start up an old computer of mine. It would not power on, so I replaced the PSU. When I powered it on, all the fans spun up and the POST beeps indicated a normal startup. The problem was there was no video output. Every couple of minutes, I hear the post code again. I think it is restarting after POST, but without video I have no idea why. Does anyone have an idea as to why this is happening, and how to fix it? EDIT: The video card is a PCI-e card. There is no integrated graphics on the motherboard. If I remove the video card, the POST indicates a missing card. When I put it back, it goes back to normal, so I know that it recognizes that the card exists.

    Read the article