  • Spare PC with XP to be used as Torrent Downloader and local Web Server HOWTO?

    - by gslide
    Hi I'm a bit in a pickle in trying to setup my old laptop using Windows XP to be able to serve as two devices in one, I want to make it a downloader for torrents and a local web server as well and how to do this? I have a wireless NIC and LAN, and I have two internet connections and i would like to be able to download torrent only on LAN and be a webserver on the Wireless, also the webserver can be accessed through the internet. The reason for trying to separate the connection is I can't have torrent downloads using all my bandwidth as my web pages cant be access as it times out or too slow. I have two broadband connections, is this even possible or would i need a different OS or program that I can download? please

    Read the article

  • How does Windows 7 taskbar "color hot-tracking" feature calculate the colour to use?

    - by theyetiman
    This has intrigued me for quite some time. Does anyone know the algorithm Windows 7 Aero uses to determine the colour to use as the hot-tracking hover highlight on taskbar buttons for currently-running apps? It is definitely based on the icon of the app, but I can't see a specific pattern of where it's getting the colour value from. It doesn't seem to be any of the following: An average colour value from the entire icon, otherwise you would get brown all the time with multi-coloured icons like Chrome. The colour used the most in the image, otherwise you'd get yellow for the SQL Server Management Studio icon (6th from left). Also, the Chrome icon used red, green and yellow in equal measure. A colour located at certain pixel coordinates within the icon, because Chrome is red -indicating the top of the icon - and Notepad++ (2nd from right) is green - indicating the bottom of the icon. I asked this question on ux.stackoverflow.com and it got closed as off-topic, but someone answered with the following: As described by Raymond Chen in this MSDN blog article: Some people ask how it's done. It's really nothing special. The code just looks for the predominant color in the icon. (And, since visual designers are sticklers for this sort of thing, black, white, and shades of gray are not considered "colors" for the purpose of this calculation.) However I wasn't really satisfied with that answer because it doesn't explain how the "predominant" colour is calculated. Surely on the SQL Management Studio icon, the predominant colour, to my eyes at least, is yellow. Yet the highlight is green. I want to know, specifically, what the algorithm is.

    Read the article

  • Hot-swap drive got new name, can I change it on-the-fly?

    - by T.J. Crowder
    One of the HDDs in my server's RAID config failed, so I took it out of the array and had the data center hot-swap it. They've done that, but now the new drive is /dev/sdc rather than /dev/sda. I suspect — correct me if I'm wrong — that if I reboot the server, it will be /dev/sda again, so I'm hesitant to add it back to the array as /dev/sdc because I don't want to lay a trap for myself to fall into on the next reboot. I'd just as soon not reboot the server if I don't need to (if I do need to, well, too bad for me). Is there a way I can change the device name from /dev/sdc to /dev/sda without rebooting? This is on Ubuntu 10.04 LTS. It's an md array ("Linux Software RAID"), where currently one of the devices (there are a couple of them) looks like this ("degraded" because I've removed the old /dev/sda from it): # mdadm --detail /dev/md0 /dev/md0: Version : 00.90.03 Creation Time : Sun Oct 11 21:07:54 2009 Raid Level : raid1 Array Size : 97536 (95.27 MiB 99.88 MB) Used Dev Size : 97536 (95.27 MiB 99.88 MB) Raid Devices : 2 Total Devices : 1 Preferred Minor : 0 Persistence : Superblock is persistent Update Time : Thu Jun 30 09:31:16 2011 State : clean, degraded Active Devices : 1 Working Devices : 1 Failed Devices : 0 Spare Devices : 0 UUID : 496be7a5:ab9177ed:7792c71e:7dc17aa4 Events : 0.112 Number Major Minor RaidDevice State 0 8 17 0 active sync /dev/sdb1 1 0 0 1 removed Thanks, Update: Reading through the kernel md documentation, I suspect that if the name changes on reboot, it won't matter. (Good design, that.) Here's why: Boot time autodetection of RAID arrays When md is compiled into the kernel (not as module), partitions of type 0xfd are scanned and automatically assembled into RAID arrays. This autodetection may be suppressed with the kernel parameter "raid=noautodetect". As of kernel 2.6.9, only drives with a type 0 superblock can be autodetected and run at boot time. The kernel parameter "raid=partitionable" (or "raid=part") means that all auto-detected arrays are assembled as partitionable. I do have md compiled into the kernel, so I'm rebuilding the array now and will do the reboot to see what happens. Even if it works, the above doesn't answer the question I actually asked, so unless someone comes along and answers that question in the meantime (I'd be interested, even if it's not necessary for what I'm doing this very moment), I'll just delete the question to keep noise down.

    Read the article

  • SSIS: Way to handle hot folder items in parallel?

    - by Dr. Zim
    We have eight Xeon (i7) cores and 16 gig of RAM on our SSIS box. We have about 200 image files we want to convert using a command line utility every day. Currently the process is using Adobe Photoshop and droplets (very manual, taking upwards of two hours a day) Using SSIS hot folders, is there a way to execute up to eight conversions at once? Is there any way to tell a process completed or execute code upon it's completion?

    Read the article

  • linux raid 1: right after replacing and syncing one drive, the other disk fails - understanding what is going on with mdstat/mdadm

    - by devicerandom
    We have an old RAID 1 Linux server (Ubuntu Lucid 10.04), with four partitions. A few days ago /dev/sdb failed, and today we noticed /dev/sda had pre-failure ominous SMART signs (~4000 reallocated sector count). We replaced /dev/sdb this morning and rebuilt the RAID on the new drive, following this guide: http://www.howtoforge.com/replacing_hard_disks_in_a_raid1_array Everything went smooth until the very end. When it looked like it was finishing to synchronize the last partition, the other old one failed. At this point I am very unsure of the state of the system. Everything seems working and the files seem to be all accessible, just as if it synchronized everything, but I'm new to RAID and I'm worried about what is going on. The /proc/mdstat output is: Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10] md3 : active raid1 sdb4[2](S) sda4[0] 478713792 blocks [2/1] [U_] md2 : active raid1 sdb3[1] sda3[2](F) 244140992 blocks [2/1] [_U] md1 : active raid1 sdb2[1] sda2[2](F) 244140992 blocks [2/1] [_U] md0 : active raid1 sdb1[1] sda1[2](F) 9764800 blocks [2/1] [_U] unused devices: <none> The order of [_U] vs [U_]. Why aren't they consistent along all the array? Is the first U /dev/sda or /dev/sdb? (I tried looking on the web for this trivial information but I found no explicit indication) If I read correctly for md0, [_U] should be /dev/sda1 (down) and /dev/sdb1 (up). But if /dev/sda has failed, how can it be the opposite for md3 ? I understand /dev/sdb4 is now spare because probably it failed to synchronize it 100%, but why does it show /dev/sda4 as up? Shouldn't it be [__]? Or [_U] anyway? The /dev/sda drive now cannot even be accessed by SMART anymore apparently, so I wouldn't expect it to be up. What is wrong with my interpretation of the output? I attach also the outputs of mdadm --detail for the four partitions: /dev/md0: Version : 00.90 Creation Time : Fri Jan 21 18:43:07 2011 Raid Level : raid1 Array Size : 9764800 (9.31 GiB 10.00 GB) Used Dev Size : 9764800 (9.31 GiB 10.00 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 0 Persistence : Superblock is persistent Update Time : Tue Nov 5 17:27:33 2013 State : clean, degraded Active Devices : 1 Working Devices : 1 Failed Devices : 1 Spare Devices : 0 UUID : a3b4dbbd:859bf7f2:bde36644:fcef85e2 Events : 0.7704 Number Major Minor RaidDevice State 0 0 0 0 removed 1 8 17 1 active sync /dev/sdb1 2 8 1 - faulty spare /dev/sda1 /dev/md1: Version : 00.90 Creation Time : Fri Jan 21 18:43:15 2011 Raid Level : raid1 Array Size : 244140992 (232.83 GiB 250.00 GB) Used Dev Size : 244140992 (232.83 GiB 250.00 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 1 Persistence : Superblock is persistent Update Time : Tue Nov 5 17:39:06 2013 State : clean, degraded Active Devices : 1 Working Devices : 1 Failed Devices : 1 Spare Devices : 0 UUID : 8bcd5765:90dc93d5:cc70849c:224ced45 Events : 0.1508280 Number Major Minor RaidDevice State 0 0 0 0 removed 1 8 18 1 active sync /dev/sdb2 2 8 2 - faulty spare /dev/sda2 /dev/md2: Version : 00.90 Creation Time : Fri Jan 21 18:43:19 2011 Raid Level : raid1 Array Size : 244140992 (232.83 GiB 250.00 GB) Used Dev Size : 244140992 (232.83 GiB 250.00 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 2 Persistence : Superblock is persistent Update Time : Tue Nov 5 17:46:44 2013 State : clean, degraded Active Devices : 1 Working Devices : 1 Failed Devices : 1 Spare Devices : 0 UUID : 2885668b:881cafed:b8275ae8:16bc7171 Events : 0.2289636 Number Major Minor RaidDevice State 0 0 0 0 removed 1 8 19 1 active sync /dev/sdb3 2 8 3 - faulty spare /dev/sda3 /dev/md3: Version : 00.90 Creation Time : Fri Jan 21 18:43:22 2011 Raid Level : raid1 Array Size : 478713792 (456.54 GiB 490.20 GB) Used Dev Size : 478713792 (456.54 GiB 490.20 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 3 Persistence : Superblock is persistent Update Time : Tue Nov 5 17:19:20 2013 State : clean, degraded Active Devices : 1 Working Devices : 2 Failed Devices : 0 Spare Devices : 1 Number Major Minor RaidDevice State 0 8 4 0 active sync /dev/sda4 1 0 0 1 removed 2 8 20 - spare /dev/sdb4 The active sync on /dev/sda4 baffles me. I am worried because if tomorrow morning I have to replace /dev/sda, I want to be sure what should I sync with what and what is going on. I am also quite baffled by the fact /dev/sda decided to fail exactly when the raid finished resyncing. I'd like to understand what is really happening. Thanks a lot for your patience and help. Massimo

    Read the article

  • Making only part of an image a hot spot link.

    - by Rkstarcass
    I have a large image and only want a rectangle portion of it to be a hot spot link that goes "Home". Here is my code that is not working. Any help on what I am missing or have done wrong? Thanks! <div id="defaultPic" runat="server"> <img src="Images/boardwise-home.jpg" alt="Boardwise Home" usemap="#map" /> <map name="map" id="boardwise-home"> <area shape="rect" coords="32,23,32,105,275,105,275,23" href="~/default.aspx" title="Boardwise Home" alt="Home" /> </map>

    Read the article

  • Finding the time to program in your spare time?

    - by Omar Kooheji
    I've got about a dozen programming projects bouncing about my head, and I'd love to contribute to some open source projects, the problem I have is that having spent the entire day staring at Visual Studio and or Eclipse (Sometimes both at the same time...) the last thing I feel like doing when I go home is program. How do you build up the motivation/time to work on your own projects after work? I'm not saying that I don't enjoy programming, it's just that I enjoy other things to and it can be hard to even do something you enjoy if you've spent all day already doing it. I think that if I worked at a chocolate factory the last thing I'd want to see when I got home was a Wonka bar.... Related: How do you keep a balance between working, training, health and family?

    Read the article

  • Hot to set class variable to be visible to its public static methods?

    - by RCola
    Why I can noy access my variable p in mull form iterate method? How to resolve a problem? Hot to set class variable to be visible to its public static methods? public class mull { public static void main(String[] args) throws InterruptedException { final JPanel p = createAndShowGUI(); Timer timer = new Timer(1000, new MyTimerActionListener()); timer.start(); try { Thread.sleep(10000); } catch (InterruptedException e) { } timer.stop(); public static void iterate(){ for (int i = 0; i < 55; i++){ // "p cannot be resolved" p.moveSquare(i*10, i*10); p.setParamsRing(i*5, i*7, 200, 200); // p.repaint(); } } } class MyPanel extends JPanel { .... } How to access variable set in another method (in this example main())? Why Eclipse forces me to use this ((MyPanel) p).setParamsRing(i*5, i*7, 200, 200); instead of this p.setParamsRing(i*5, i*7, 200, 200);?

    Read the article

  • Are swapped in hot-swap drives allocated the same Windows drive letter each time?

    - by Margaret
    We are intending on purchasing a dedicated machine to perform the company's backups. We were considering buying the Dell T310, with the theory that we could swap the drives in and out for offsite backup. (As in, take out a drive, put a version a couple of days' old in its place, the old backup is updated to the current version.) One thing that may stymie this, though, is the system changing drive letters as things get moved in and out. Does anyone know whether this happens?

    Read the article

  • External HDD incorrectly detected as internal - how change to enable hot swap/eject?

    - by Sam
    Hi All, I have win 7 x64 Home Prem. The HDD is a seagate barracuda, 7200.7 ST3120827AS. 3.5", Serial: 3ms006n6, Firmware: 3.42 (no further updates) NexStar CX External case (drivers installed). I have three drives: WD320 with OS installed WD750 data storage (internal) seagate 120 (external) - connected via esata board connected to sata on motherboard (MSI p43 neo) Tried uninstalling HDD in device manager to no effect. Also the internal WD750 is detected as an external drive and win taskbar icon allows for it to be ejected (unlike the seagate). All drives are configured - Online, Simple, Basic, NTFS, Active, Primary Partition (except c drive). The seagate was previously used as a primary disk with XP operating system so I deleted the volume and created/reformatted (not quick). HDD is no longer "Active". But did not fix problem. Background Originally, I installed win 7 with the bios set to IDE and forgot to install the chipset drivers. Then I changed win 7 to install the AHCI drivers, changed the bios to AHCI and rebooted. Win 7 loaded drivers but WD HDD gave problems/crashed. I installed chipset drivers and latest intell storage matrix software thingie (in safe mode). Everything worked fine after that except for the problem of not corrrectly detecting the external drive] I have noticed that under the driver properties (and similarly in the registry) the two drives are configured differently (e.g. in driver details property capabilities for the WD the value is set to 0000006, CM_DEVCAP_REMOVABLE & EJECTSUPPORTED - whereas the seagate shows 0000080 & CM_DEVCAP_SURPRISEREMOVALOK). Any easy way to configure things? I tried physically swapping the sata connections on the mainboard without success So far I have found that a solution to my problem might be to perform some reg changes: http://superuser.com/questions/12955/how-do-i-remove-the-option-to-eject-sata-drives-from-the-windows-7-tray-icon

    Read the article

  • External HDD incorrectly detected as internal - how change to enable hot swap/eject?

    - by Sam
    I have win 7 x64 Home Prem. The HDD is a seagate barracuda, 7200.7 ST3120827AS. 3.5", Serial: 3ms006n6, Firmware: 3.42 (no further updates) NexStar CX External case (drivers installed). I have three drives: WD320 with OS installed WD750 data storage (internal) seagate 120 (external) - connected via esata board connected to sata on motherboard (MSI p43 neo) Tried uninstalling HDD in device manager to no effect. Also the internal WD750 is detected as an external drive and win taskbar icon allows for it to be ejected (unlike the seagate). All drives are configured - Online, Simple, Basic, NTFS, Active, Primary Partition (except c drive). The seagate was previously used as a primary disk with XP operating system so I deleted the volume and created/reformatted (not quick). HDD is no longer "Active". But did not fix problem. Background Originally, I installed win 7 with the bios set to IDE and forgot to install the chipset drivers. Then I changed win 7 to install the AHCI drivers, changed the bios to AHCI and rebooted. Win 7 loaded drivers but WD HDD gave problems/crashed. I installed chipset drivers and latest intell storage matrix software thingie (in safe mode). Everything worked fine after that except for the problem of not corrrectly detecting the external drive] I have noticed that under the driver properties (and similarly in the registry) the two drives are configured differently (e.g. in driver details property capabilities for the WD the value is set to 0000006, CM_DEVCAP_REMOVABLE & EJECTSUPPORTED - whereas the seagate shows 0000080 & CM_DEVCAP_SURPRISEREMOVALOK). Any easy way to configure things? I tried physically swapping the sata connections on the mainboard without success So far I have found that a solution to my problem might be to perform some reg changes: How do I remove the option to eject SATA drives from the Windows 7 tray icon?

    Read the article

  • Why does my laptop shut down, does it get too hot?

    - by Kevin P.
    When I play games, or use powerful-applications such as Autodesk Maya, my laptop just shuts down, ofcourse without any warning at all. This is what I've tried so far: Cleaned my fan, completely! Checked if I have enough RAM and good enough graphics card, and I do. (6 GB RAM, Nvidia GeForce GT540M with 2 GB VRAM) None of these options worked. Even tried to clean my fan twice! Now, I have some options I could also try, but I don't know if that have anything to do with it or not. I was thinking reinstalling my Windows 7, because maybe it has to do something wrong with the installation? My laptop is about a year old, and this problem just happend out of no where, short after I downgraded from Windows 8 Release Preview to my original Windows 7.

    Read the article

  • How to delete removed devices from a mdadm RAID1?

    - by Kabuto
    I had to replace two hard drives in my RAID1. After adding the two new partitions the old ones are still showing up as removed while the new ones are only added as spare. I've had no luck removing the partitions marked as removed. Here's the RAID in question. Note the two devices (0 and 1) with state removed. $ mdadm --detail /dev/md1 mdadm: metadata format 00.90 unknown, ignored. mdadm: metadata format 00.90 unknown, ignored. /dev/md1: Version : 00.90 Creation Time : Thu May 20 12:32:25 2010 Raid Level : raid1 Array Size : 1454645504 (1387.26 GiB 1489.56 GB) Used Dev Size : 1454645504 (1387.26 GiB 1489.56 GB) Raid Devices : 3 Total Devices : 3 Preferred Minor : 1 Persistence : Superblock is persistent Update Time : Tue Nov 12 21:30:39 2013 State : clean, degraded Active Devices : 1 Working Devices : 3 Failed Devices : 0 Spare Devices : 2 UUID : 10d7d9be:a8a50b8e:788182fa:2238f1e4 Events : 0.8717546 Number Major Minor RaidDevice State 0 0 0 0 removed 1 0 0 1 removed 2 8 34 2 active sync /dev/sdc2 3 8 18 - spare /dev/sdb2 4 8 2 - spare /dev/sda2 How do I get rid of these devices and add the new partitions as active RAID devices? Update I seem to have gotten rid of them. My RAID is resyncing, but the two drives are still marked as spares and are number 3 and 4, which looks wrong. I'll have to wait for the resync to finish. All I did was to fix the metadata error by editing my mdadm.conf and rebooting. I tried rebooting before, but this time it worked for whatever reason. Number Major Minor RaidDevice State 3 8 2 0 spare rebuilding /dev/sda2 4 8 18 1 spare rebuilding /dev/sdb2 2 8 34 2 active sync /dev/sdc2

    Read the article

  • How to get rid of a stubborn 'removed' device in mdadm

    - by T.J. Crowder
    One of my server's drives failed and so I removed the failed drive from all three relevant arrays, had the drive swapped out, and then added the new drive to the arrays. Two of the arrays worked perfectly. The third added the drive back as a spare, and there's an odd "removed" entry in the mdadm details. I tried both mdadm /dev/md2 --remove failed and mdadm /dev/md2 --remove detached as suggested here and here, neither of which complained, but neither of which had any effect, either. Does anyone know how I can get rid of that entry and get the drive added back properly? (Ideally without resyncing a third time, I've already had to do it twice and it takes hours. But if that's what it takes, that's what it takes.) The new drive is /dev/sda, the relevant partition is /dev/sda3. Here's the detail on the array: # mdadm --detail /dev/md2 /dev/md2: Version : 0.90 Creation Time : Wed Oct 26 12:27:49 2011 Raid Level : raid1 Array Size : 729952192 (696.14 GiB 747.47 GB) Used Dev Size : 729952192 (696.14 GiB 747.47 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 2 Persistence : Superblock is persistent Update Time : Tue Nov 12 17:48:53 2013 State : clean, degraded Active Devices : 1 Working Devices : 2 Failed Devices : 0 Spare Devices : 1 UUID : 2fdbf68c:d572d905:776c2c25:004bd7b2 (local to host blah) Events : 0.34665 Number Major Minor RaidDevice State 0 0 0 0 removed 1 8 19 1 active sync /dev/sdb3 2 8 3 - spare /dev/sda3 If it's relevant, it's a 64-bit server. It normally runs Ubuntu, but right now I'm in the data centre's "rescue" OS, which is Debian 7 (wheezy). The "removed" entry was there the last time I was in Ubuntu (it won't, currently, boot from the disk), so I don't think that's not some Ubuntu/Debian conflict (and they are, of course, closely related). Update: Having done extensive tests with test devices on a local machine, I'm just plain getting anomalous behavior from mdadm with this array. For instance, with /dev/sda3 removed from the array again, I did this: mdadm /dev/md2 --grow --force --raid-devices=1 And that got rid of the "removed" device, leaving me just with /dev/sdb3. Then I nuked /dev/sda3 (wrote a file system to it, so it didn't have the raid fs anymore), then: mdadm /dev/md2 --grow --raid-devices=2 ...which gave me an array with /dev/sdb3 in slot 0 and "removed" in slot 1 as you'd expect. Then mdadm /dev/md2 --add /dev/sda3 ...added it — as a spare again. (Another 3.5 hours down the drain.) So with the rebuilt spare in the array, given that mdadm's man page says RAID-DEVICES CHANGES ... When the number of devices is increased, any hot spares that are present will be activated immediately. ...I grew the array to three devices, to try to activate the "spare": mdadm /dev/md2 --grow --raid-devices=3 What did I get? Two "removed" devices, and the spare. And yet when I do this with a test array, I don't get this behavior. So I nuked /dev/sda3 again, used it to create a brand-new array, and am copying the data from the old array to the new one: rsync -r -t -v --exclude 'lost+found' --progress /mnt/oldarray/* /mnt/newarray This will, of course, take hours. Hopefully when I'm done, I can stop the old array entirely, nuke /dev/sdb3, and add it to the new array. Hopefully, it won't get added as a spare!

    Read the article

  • Gnome3 pointer barrier not working with dual monitors

    - by Nathan
    I have a dual monitor setup using Gnome3. Misc Info : In the past I used Fedora, there was a pointer barrier between my two monitors in the upper left corner so that I can hit the hot corner when moving from the right monitor to the left monitor. Problem : However, with my new Ubuntu installation, the barrier no longer exists and my mouse pointer glides straight to the next screen. This makes that hot corner nearly useless. I've looked around, messed with the values in /usr/share/gnome-shell/js/ui/layout.js, but I can't figure out how to make the pointer barrier work. may someone suggest hot to get the full utilization of hot cornet.

    Read the article

  • Hot to make COM ActiveX object work in IE 64 bit?

    - by Kurtevich
    Hi! I have a COM object embeded in ASP.NET page using <object classid="clsid:XXX...">. It works in IE 32 bit, but does not work in IE 64 bit - can't access its functions. There are no error messages, no event logs where I can get some information. The dll is in C#, includes COM visible class, compiled for Any CPU (though I also tried x86), and registered during client installation by executing regasm. This creates registry keys, well everything works fine except for IE 64. I searched internet about the issue or at least some guidlines and didn't find anything. I received an answer on another forum, something about _MERGE_PROXYSTUB (I guess it's preprocessor definition?) and ProxyStubClsid32 registry key, but not very detailed. Well, I searched again, didn't find much, and experimented: rebuilt with _MERGE_PROXYSTUB defined, created ProxyStubClsid32 keys everywhere, but with no result. What can be at least possible solutions or points to look at? Maybe there is a way at least to get the logs about why IE 64 can't access it?

    Read the article

  • Hot to find a control in a java runtime?

    - by Kovu
    Hi, I will write a proxy for something For this I must write data very ugly in 2 textboxes in a webpage (http://www.knuddelz.de). You see: username and password and a button with a login. How to find the control in C#.net 2.0 or 3.5 and wirte data in it?

    Read the article

  • Hot to declare itemTemplate that has Itemsource as Enum Values in WPF?

    - by Ashish Ashu
    I have a enum let's say Enum MyEnum { FirstImage, SecondImage, ThirdImage, FourthImage }; I have binded this Enum to my combobox in XAML. While defining an combobox I have defined an ItemTemplate of combox to take Two UI element: TextBlock that show the enum value (Description) Image I have done this much in XAML. I am wondering where I can specify the Image corrosponding to each item of Enum. Is that possible through data trigger ? I really appreciate if anyone have the XAML for this scenario. Many Thanks in advance

    Read the article

  • Hot to get custom http-header in asp.net?

    - by Sirius Lampochkin
    I have an asp.net appliction on the one server. There I've added code on server-side in Page_Load: Response.AddHeader("key", "password-key-from-hotel"); On the client side I have a form: $lt;form ... action="www.link-to-another-domaint" >   <input type="hidden" id="asd" value="fgh" > .... </form> <script type="text/javascript">   document.forms[0].submit(); </script> Then on the other domain - there is also my other application - I'm trying to get the hedaer "key" by this code: Request.Headers["key"].ToString(); But there is no such header. Is there is a desicion? Where is my mistake?

    Read the article

  • Suggestions for splitting server roles amongst Hyper-V virtual servers / RAID6 or RAID10? / AppAssure

    - by Anon
    We have 2 Hyper-V hosts at present running 1 virtual server that was converted from a physical box running all roles. My plan is to split the roles over various virtual machines, upgrading to the latest software versions as I go, and use the backup server as a standby in case the main server fails. AppAssure backup software has a feature called Virtual Standby, so the VHD's can be ready to be fired up on the backup server if necessary. Off-site backups will be done via external USB drive for now. I'm just seeking some input/suggestions into how I'm planning to split the roles out amongst various virtual servers. Also, I'm curious how to setup the storage on the servers. We do not have any NAS's, SAN'S or any budget for this. What would the best RAID level be to use? I'm thinking either RAID6 (which is currently used) however I'm concerned about the write speeds, or RAID10 but again I'm worried that I can only lose 1 drive (from the same mirror) as opposed to any 2 with RAID6. I realise I have a hot swap for this, but what if a further drive fails during a rebuild? Is the write penalty of RAID6 worth the extra reliability over RAID10? Or will it be too slow with all the roles I am planning, therefore RAID10 is my only real option? The reason for the needed redundancy is I am the only technician and I'm not always on-site. Options I've considered: 1) 5 drives in RAID6 set, 200gb for host OS, rest for VM storage. 1 drive for hot swap - this is how it is currently setup 2) 4 drives in RAID10 set, 200gb for host OS, rest for VM storage. 2 drives for hot swap 3) 4 drives in RAID10 set for VM storage, 2 drives in RAID1 set for host OS. No drives for hot swap - While this is probably the best option with the amount of drives I have, I don't like the idea of having no hot swap 4) 3 drives in RAID6 set for VM storage, 2 drives in RAID1 set for host OS. 1 drive for hot swap All options give us enough storage capacity for our files, etc. We don't have any budget for extra drives or extra hot swap HD chassis for the servers. We have about 70 clients and about 150 users. MAIN SERVER Intel Xeon 5520 @ 2.27 GHz (2 processors) 16GB RAM 6 x 1TB Seagate Barracuda ES.2 Enterprise SATA drives Intel SRCSATAWB RAID controller Virtual machine workload using Hyper-V on Windows Server 2008 R2: DC01 - Active Directory Domain Controller / DNS server / Global catalog - 1GB RAM DC02 - Active Directory Domain Controller / DNS server / Global catalog - 1GB RAM Member Server - DHCP server, File server, Print server - 1GB RAM SCCM Member Server - 4GB RAM Third Party Software Member Server - A/V server, Ticketing software, etc - 4GB RAM Exchange 2007 - 4GB RAM - however we are probably migrating to a hosted solution, therefore freeing up resources BACKUP SERVER Intel Xeon E5410 @ 2.33GHz (2 processors) 16GB RAM 6 x 2TB WD RE4 SATA drives Intel SRCSASRB RAID controller Virtual machine workload using Hyper-V on Windows Server 2008 R2: AppAssure backup software - 8GB RAM

    Read the article