Search Results

Search found 2840 results on 114 pages for 'ports'.

Page 90/114 | < Previous Page | 86 87 88 89 90 91 92 93 94 95 96 97  | Next Page >

  • Apache22 on FreeBSD - Starts, does not respond to requests

    - by NuclearDog
    Hey folks! I'm running Apache 2.2.17 with the peruser MPM on FreeBSD 8.2-RC1 on Amazon's EC2 (so it's XEN). It was installed from ports. My problem is that, although Apache is running, listening for, and accepting connections, it doesn't actually respond to any or show them in the log at all. If I telnet to the port it's listening on and type out an HTTP request: GET / HTTP/1.1 Host: asdfasdf And hit enter a couple of times, it just sits there... Nothing. No response requesting with a browser either. There doesn't appear to be anything helpful in the error log: [Sun Jan 09 16:56:24 2011] [warn] Init: Session Cache is not configured [hint: SSLSessionCache] [Sun Jan 09 16:56:25 2011] [notice] Digest: generating secret for digest authentication ... [Sun Jan 09 16:56:25 2011] [notice] Digest: done [Sun Jan 09 16:56:25 2011] [notice] Apache/2.2.17 (FreeBSD) mod_ssl/2.2.17 The access log stays empty: root:/var/log# wc httpd-access.log 0 0 0 httpd-access.log root:/var/log# I've tried with accf_http and accf_data both enabled and disabled, and with both the stock configuration and my customized config. I also tried uninstalling apache22-peruser-mpm and just installing straight apache22... Still no luck. I tried removing all of the LoadModule lines from httpd.conf and just re-enabled the ones that were necessary to parse the config. Ended up with only the following loaded: root:/usr/local/etc/apache22# /usr/local/sbin/apachectl -M Loaded Modules: core_module (static) mpm_peruser_module (static) http_module (static) so_module (static) authz_host_module (shared) log_config_module (shared) alias_module (shared) Syntax OK root:/usr/local/etc/apache22# Same results. Apache is definitely what's listening on port 80: root:/usr/local/etc/apache22# sockstat -4 | grep httpd root httpd 43789 3 tcp4 6 *:80 *:* root httpd 43789 4 tcp4 *:* *:* root:/usr/local/etc/apache22# And I know it's not a firewall issue as there is nothing running locally, and connecting from the local box to 127.0.0.1:80 results in the same issue. Does anyone have any idea what's going on? Why it would be doing this? I've exhausted all of my debugging expertise. :/ Thanks for any suggestions!

    Read the article

  • Win 2003 SBS - secure enough by default?

    - by Pekka
    I have to set up a Windows 2003 Small Business Server to work as a Subversion repository and possibly as an E-Mail server later. The machine is a virtual one, hosted with a hosting company, and freshly initialized. I used the Security Configuration Wizard to deactivate all server roles. After I install Subversion, I will open the necessary ports for the service; in addition, obviously, RDP will stay open so I can remote control the machine. Automatic updates are activated, and I will set up E-Mail notification every time somebody logs on to the server. I'm a programmer and not a professional systems administrator, so I would like to know whether you would regard this a sane and secure setup for a (publicly available) box to host sensitive code and/or E-Mail on. Is there anything in addition I should do to make the machine secure? Is there anything I can do on a long-term basis to keep the machine secure, apart from monitoring the event log (as far as I can make sense out of it), and seeing that any hotfixes are installed properly?

    Read the article

  • How to work around blocked outbound hkp port for apt keys

    - by kief_morris
    I'm using Ubuntu 9.10, and need to add some apt repositories. Unfortunately, I get messages like this when running sudo apt-get update: W: GPG error: http://ppa.launchpad.net karmic Release: The following signatures couldn't be verified because the public key is not available: NO_PUBKEY 5A9BF3BB4E5E17B5 W: GPG error: http://ppa.launchpad.net karmic Release: The following signatures couldn't be verified because the public key is not available: NO_PUBKEY 1DABDBB4CEC06767 So, I need to install the keys for these repositories. Under 9.10 we now have the option to do this: sudo add-apt-repository ppa:nvidia-vdpau/ppa See this Ubuntu help article for details. This is great, except that I'm running this on a workstation behind a firewall which blocks outbound connections to pretty much all ports except those required by secretaries running Windows and IE. The port in question here is the hkp service, port 11371. There appear to be ways to manually download keys and install them on apt's keyring. There may even be a way to use add-apt-repository or wget or something to download a key from an alternative server making it available on port 80. However, I haven't yet found a concise set of steps for doing so. What I'm looking for is: How to find a public key for an apt-package (recommendations for resources which have these, and/or tips for searching. Searching for the key hash doesn't seem all that effective so far.) How to retrieve a key (can it be done automatically using gpg or add-apt-repository?) How to add a key to apt's keyring Thanks in advance.

    Read the article

  • SSH sometimes screws up connection when terminal overflows?

    - by SeveQ
    I've got a problem with SSH on a Debian Lenny based server (it's a vHost within a Xen environment, booted on a Xen kernel). I hope someone can help me with this. The SSH connection seems somehow getting screwed up frequently when the terminal overflows (new lines beyond the bottom of the terminal, usually forcing it to scroll). The connection gets lost but not regularly disconnected. It nearly always happens when I do the following: an existing SSH connection gets disconnected (regularly) I order putty to reestablish the connection login-prompt appears at the very bottom of the putty terminal window I enter my login-name, press the enter key I'm asked for the password, I enter it, press the enter key and BOOM! Nothing more happens. I have to reconnect again. So it is reproducable. I'm not totally sure if the connection crashes before or after I enter the password. Furthermore it also happens when there is much text to be displayed (for example when I compile something or do an ls -l on a directory with many entries). Using 'screen', however, helps to reduces the frequency of occurence but doesn't solve the problem completely. It's occurence is independent from which terminal software I use. I mostly use putty but it also happens with other clients. I certainly hope somebody can help me solving this problem. Thanks in advance! //edit: I've just made a Wireshark trace of the ssh connection and there is nothing, I repeat, nothing different between the working and the failing connection (at least aside from frame numbers, ports and times that obviously can't be equal). This leads me to the assumption that the error has to happen on the server's side.

    Read the article

  • What is the best way to connect 3 switches with a router?

    - by Carlos Morales
    Hello everyone, I'm trying to rebuild the network from my work and I was thinking what is the best way to connect three switches and a router. The router has 4 ports so I thought to connect 2 switches to the router (each switch connected with 2 cables to the router) and then connect the third switch to one of the others with two cables. So is like this, two cables from switch one to the router, two cables from switch two to the router and two cables from switch 3 to switch 1 or 2. So my questions are: Is it better to connect the router to each switch with a cable or the more cables you have the better? If I connect the switch 3 to switch 1 or 2 is it better to connect it with a cable or you get better performance with more cables. If I'm wrong and there is a better or more efficient way to connect them please let me know. The router is a Netgear RP114 (I'll upgrade it to a Sonicwall NSA 240), switch 1 is a Netgear GS748T, switch 2 is a Cisco Catalyst 2924-XL and switch 3 is a D-link DGS-1024D Thank you very much

    Read the article

  • How do I stop panning on a monitor that supports a specific resolution?

    - by IronicMuffin
    Hi all, I've been battling this for a few days now. Any and all help is appreciated. I have a planar monitor with a native res of 1280x1024. At one point, I had used PowerStrip to override "something" and set the res to 1600x1200, and it worked great. I then installed new intel graphics drivers for my 86895g (or w/e model) video card, which screwed up whatever settings I had. If I set it to 1600x1200 this time, it would set the res correctly, but give me a 1280x1024 viewport and the screen would pan when the mouse got to the edges of the screen. Absolutely not useful. Ok, so I was limited to 1280x1024 now. W/e. Now...enter new video card with two video ports. I have two monitors now and the latest nVidia drivers. I decide to try to get dual 1600x1200 going...ended up screwing the original monitor up so much now that it's at 1280x1024, with a 1024x768 viewport and panning! Absolutely not usable now. So what I need, and I can't seem to find on any forums, is help doing one or more of the following: Clearing out all monitor/edid info out of the windows registry without corrupting the registry. Actually correctly override the EDID values and get my sweet res back. Some other way of getting back to at least dual 1280x1024 with NO panning. Note: My device manager shows 4 monitors for some reason. My registry shows entries for all sorts of monitors that have been hooked up to the machine over the years. It's making it difficult to debug. Experience with PowerStrip would be helpful. I've been mucking with Phoenix EDID designer and MonInfo as well, but I'm stumbling around in the dark with these. Windows XP SP2 nVidia GeForce 6200 nVidia drivers: v258.96 Monitor: Planar PL 1910M Thanks!

    Read the article

  • .htaccess redirect to error page if port is not 80

    - by Momo
    I'm running a portable server through usb stick. The thing is I also have WAMP installed in my local machine and Apache somehow gets started on windows startup, because of some random reason which I don't recall now and it can't be changed. I want to prepare my portable server in situations like this, so closing httpd.exe from process and starting my portable server is not an option. Anyway, because of already active httpd.exe my portable server's WordPress site can only be accessed through localhost:81 - this is a problem as WP site is very dependent on the URL and I don't want to include the url with port on WP database. Here is what I want to do through .htaccess: On any path except for error.php file check if not port 80 If not port 80 redirect to /error.php?code=port It it possible for it to have priority over WP redirection or URL handling? In the error.php I provided info on how to manually close httpd.exe and such so my family and friends can access the portable site. It's sort of like a gallery and calender application for events and other such stuff... Please help? I'm I can't figure it out at all. I know others may not have apache already running, but I want to prepare for such a situation. Something like the following, but the following doesn't work. # BEGIN WordPress <IfModule mod_rewrite.c> <If "%{SERVER_PORT} = 80"> RewriteEngine On RewriteBase / RewriteRule ^index\.php$ - [L] RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule . /index.php [L] </If> <Else> RewriteEngine On RewriteRule ^(error.php)($|/) - [L] RewriteRule ^(.*)$ /error.php?code=port [L] </Else> </IfModule> # END WordPress By the way, the portable server Server2Go automatically generates vhosts based o the hostname set on it's config file and changes ports if the port (e.g. 80) is already open.

    Read the article

  • Asus K55VM usb 3.0 issue

    - by user2141481
    Good day superusers! I own the above laptop and I found out that there are some unknown and unusual issues with usb 3.0 ports. I haven't noticed anything strange until now. I got a new toshiba usb 3.0 external hdd and when I try to copy larger amount of data from my disk to the external hdd, the OS(windows 7) randomly starts ignoring the external hdd. It doesn't shut it down, it kinda just stops responding but the light on the hdd is still lit. I get an error that the files cannot be copied. I have reinstalled windows 7, installed all drivers(including intel chipset drivers of course) and the issue is still present. It acts normal when copying small amount of data. Also, I heard that some intel chipsets have an issue with usb, something about the connectors not transferring power when the usb device enters some kind of "low power mode" causing the device to stop responding and you need to plug it out and in again. But the thing is, my Intel® Chief River Chipset HM76 is not on the list of affected hardware(not ENTIRELY sure though). If anyone has any idea of what the problem to this might be, I'd be greatful. Edit: The hdd works perfectly fine even for large amounts of data if plugged in the usb 2.0 port!

    Read the article

  • Port Forwarding failing only to Ubuntu servers from Draytek router

    - by Rufinus
    I know this is a kinda unusal question, but Draytek support (..which is very eager to solve the issue) seems to reach its limits. Scenario: Draytek Vigor Multiwan router with current firmware. Multiple WAN IP Aliases on one of the wan ports DMZ (or port forwarding doesnt matter) from wan ip alias to internal host currently i have two internal hosts: 192.168.0.51 (Ubuntu) 192.168.0.53 (Debian) both should be accessible from outside via one of the wan ip aliases. both are accessible with their internal ip's at all times (!) If the router gots restartet, both external ips are forwarding to its internal hosts. But after a few minutes up to 2 hours, the ubuntu host is no longer reachable via its external interface. The debian hosts on the other hand is reachable. In what does ubuntu differs from debian ? I know at least of one user with the exact same problem. see http://ubuntuforums.org/showthread.php?p=10994279 Any ideas ? TIA EDIT: via ping diagnostics directly on vigor, 192.168.0.53 is pingable, 192.168.0.51 is not. but both hosts are perfectly reachable from anywhere inside the network. if i restart ubuntu networking it works again for a short time.... i'm out of ideas.. EDIT 2: after further investigation, i noticed a ping from .51 to the network (or a host in the internet) is enough to make the port-forwarding working again. So i will add an Cronjob as a "keep-alive" ping. This will solve the problem, but the reason for this behaivor is still in the dark. Thanks to all commentors.

    Read the article

  • Nginx > Varnish > Gunicorn Error Too many Redirections

    - by kollo
    I have the following config: Nginx Varnish Gunicorn Django I want to cache 2 versions of same site (mobile & web) with Varnish. Gunicorn : WEB: gunicorn_django --bind 127.0.0.1:8181 MOBILE: gunicorn_django --bind 127.0.0.1:8182 Nginx: WEB: server { listen 80; server_name www.mysite.com; location / { proxy_pass http://127.0.0.1:8282; # pass to Varnish proxy_set_header X-Real-IP $remote_addr; proxy_set_header Host $host; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; } } MOBILE: server { listen 80; server_name m.mysite.com; location / { proxy_pass http://127.0.0.1:8282; # pass to Varnish proxy_set_header X-Real-IP $remote_addr; proxy_set_header Host $host; proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; } } Varnish: default.vcl backend mobile_mysite { .host = "127.0.0.1"; .port = "8182"; } backend mysite { .host = "127.0.0.1"; .port = "8181"; } sub vcl_recv { if (req.http.host ~ "(?i)^(m.)?mysite.com$") { set req.http.host = "m.mysite.com"; set req.backend = mobile_mysite; }elsif (req.http.host ~ "(?i)^(www.)?mysite.com$") { set req.http.host = "mysite.com"; set req.backend = mysite; } if (req.url ~ ".*/static") { /* do not cache static content */ return (pass); } } The problem: On Nginx if I setup Mobile version with Varnish (port 8282) and let WEB version with Gunicorn( port 8181), MOBILE is cached by varnish, both WEB & MOBILE works but WEB is not cached. If I set the proxy_pass of WEB version to Varnish (port 8282) and restart Nginx I got an error when accessing web version (www.mysite.com) "Too many redirections" . I Think my problem come from the Varnish config file, as the site works well if I setup Nginx proxy_pass to Gunicorn ports (MOBILE & WEB).

    Read the article

  • Bypassing SQUID on freebsd with PF

    - by epema
    I have PF+SQUID31 on FREEBSD-9.0, and I want to have some hosts(aka goodguys) to bypass the proxy, so that torrents are not logged. Also, I am not sure about transparent. It means that I dont have to configure proxy settings on the client side right? I have tried doing a redirect no rdr on $int_if inet proto {tcp,udp} from 192.168.1.233/32 to any However, no luck :( Here is a quick look of my conf files: SQUID /usr/local/etc/squid/squid.conf http_port 192.168.1.1:8080 transparent RC /etc/rc.conf: gateway_enable="YES" pf_enable="YES" pf_rules="/usr/local/etc/pf.conf" pflog_enable="YES" squid_enable="YES" I have squid31 installed from ports with SQUID_PF "Enable transparent proxying with PF" on PF /usr/loca/etc/pf.conf: int_if="re0" ext_if="bge0" localnet="{ 192.168.1.0/24 }" table <goodguys> const { "192.168.1.219", "192.168.1.233" } set block-policy drop set skip on lo0 scrub in all fragment reassemble scrub out all random-id max-mss 1440 block in on $ext_if pass out on $ext_if keep state block in on $int_if pass in on $int_if inet proto tcp from $int_if:network to $int_if port 8080 keep state pass in on $int_if inet proto udp from $int_if:network to $int_if port 21 keep state pass in on $int_if inet proto udp from $int_if:network to $int_if port 22 keep state pass in on $int_if inet proto udp from $int_if:network to $int_if port 53 keep state pass in on $int_if inet proto tcp from $int_if:network to any port { smtp, pop3 } keep state pass in on $int_if inet proto icmp from $int_if:network to $int_if keep state pass out on $int_if keep state What lines should I add in conf files? I am assuming that the problem is on the firewall(pf).

    Read the article

  • Is it possible to change an "Unidentified Network" into a "Home" or "Work" network on Windows 7

    - by Rhys
    I have a problem with Windows 7 RC (7100). I frequently use a crossover network cable on WinXP with static IP addresses to connect to various industrial devices (e.g. robots, pumps, valves or even other Windows PCs) that have Ethernet network ports. When I do this on Windows 7, the network connection is classed as an "Unidentified Network" in Networks and Sharing Center and the public firewall profile is enforced by Windows. I do not want to change the public profile and would prefer to use the Home or Work profile instead. For other networks like Home and Work I'm able to click on them and change the classification. This is not available for unidentified networks. My questions are these:- Is there a way to manual override the "Unidentified Network" classification? What tests are performed on the network that fail, therefore classifying it as an "Unidentified Network" By googling (hitting mainly vista issues) it seems that you need to ensure that the default gateway is not 0.0.0.0. I've done this. I've also tried to remove IPv6 but this does not seem possible on Windows 7.

    Read the article

  • How to make Virtualbox, OpenVPN, and Win2008 Web R2 like one another?

    - by Aquitaine
    Back with web developer guy wearing net admin hat. Hopefully this is an easy one. We have two servers on a public network at a hosted facility. Server A is our public-facing web server and server B is our database server. Both are running Windows 2008 Server R2 Web Edition. We want Server B isolated from everything except Server A, such that anyone who has to connect to server B goes through the VPN on Server A. It's not perfect since we have no access to do this on the router side, but it's what we've got. We've set up VirtualBox and OpenVPN Access Server on Server A. It has one network interface set to 'NAT' mode, such that OpenVPN gets its IP at 10.0.2.x, and to connect to the OpenVPN interface, I go to the local IP for the Virtualbox network adapter, 192.168.56.x, which works as I configured the appropriate ports using VBoxManage. My question is, do I need to be using Bridged Networking and give the VPN server its own IP, or is there some way to tell the server (either Windows or the Virtualbox OpenVPN) that 'any public connection on the real external IP on port X should be directed to this internal LAN address of 192.168.1.x on port Y'? OpenVPN itself doesn't seem to be aware of the server's real external IP unless we put it in Bridged networking mode; is that necessary or advisable? We're without RRAS since this is Web edition, but I feel like what we're going for is pretty simple. Thanks! Aq

    Read the article

  • python reports socket in use, netstat and others claim its not

    - by captainmish
    We have a strange socket issue with a RHES3 box: Python 2.4.1 (#1, Jul 5 2005, 19:17:11) [GCC 3.2.3 20030502 (Red Hat Linux 3.2.3-52)] Type "help", "copyright", "credits" or "license" for more information. >>> import socket >>> s = socket.socket() >>> s.bind(('localhost',12351)) Traceback (most recent call last): File "<stdin>", line 1, in ? File "<string>", line 1, in bind socket.error: (98, 'Address already in use') This seems normal, lets see what has that socket: # netstat -untap | grep 12351 {no output} # grep 12351 /proc/net/tcp {no output} # lsof | grep 12351 {no output} # fuser -n tcp 12351 {no output, repeating the python test fails again} # nc localhost 12351 {no output} # nmap localhost 12351 {shows port closed} Other high ports work fine (eg 12352 works) Is there something magic about this port? Is there somewhere else I can look? Where does python find out that socket is in use that netstat doesnt know about? Any other way I can find out what/if that socket is?

    Read the article

  • The USB mouse sticks in Windows 7 after automatic attempt to fix the boot

    - by chelder
    Avast Antivirus asked me to delete a probable virus and to restart to perform a checking. I had to stop the checking at the middle of the procedure as I needed the computer. It was imposible to turn off the computer pushing the power button (as it entered in suspension mode, no matter how long I kept pushed the power button). I removed the battery as the only way to restart the computer. Windows 7 said that there is a problem to iniziate Windows. Windows 7 tried to fix the problem without success. Windows 7 started after that though. Everything is OK but the USB mouse. The USB mouse sticks and freezes each couple of seconds more or less. The tactile mouse (PS2) works well. I googled for solutions but the posible solutions didn't work for me. What happened? How could I fix it without formatting and reinstalling everything? UPDATE: this is what I did: Change the mouse from one usb port to another Test another mouse Set the number of cores of the CPU manually with msconfig Power management: not disable usb ports Check hard disk errors

    Read the article

  • iptables rules to allow HTTP traffic to one domain only

    - by Emily
    Hi everyone, I need to configure my machine as to allow HTTP traffic to/from serverfault.com only. All other websites, services ports are not accessible. I came up with these iptables rules: #drop everything iptables -P INPUT DROP iptables -P OUTPUT DROP #Now, allow connection to website serverfault.com on port 80 iptables -A OUTPUT -p tcp -d serverfault.com --dport 80 -j ACCEPT iptables -A INPUT -m conntrack --ctstate ESTABLISHED,RELATED -j ACCEPT #allow loopback iptables -I INPUT 1 -i lo -j ACCEPT It doesn't work quite well: After I drop everything, and move on to rule 3: iptables -A OUTPUT -p tcp -d serverfault.com --dport 80 -j ACCEPT I get this error: iptables v1.4.4: host/network `serverfault.com' not found Try `iptables -h' or 'iptables --help' for more information. Do you think it is related to DNS? Should I allow it as well? Or should I just put IP addresses in the rules? Do you think what I'm trying to do could be achieved with simpler rules? How? I would appreciate any help or hints on this. Thanks a lot!

    Read the article

  • Running docker in VPC and accessing container from another VPC machine

    - by Bogdan Gaza
    I'm having issues while running docker in AWS VPC. Here is my setup: I've got two machines running in VPC: 10.0.100.150 10.0.100.151 both having an elastic IPs assigned to them, both running in the same internet enabled subnet. Let's say I'm running a web server that serves static files in a container on the 10.0.100.150 machine the container: IP: 172.17.0.2 port 8111 is forwarded on the 8111 port on the machine. I'm trying to access the static files from my local machine (or another non-VPC machine also tried an EC2 instance not running in the VPC) and it work flawlessly. If I try to access the files from the other machine (10.0.100.151) it hangs. I'm using wget to pull the files. Tried to debug it with tcpdump and ngrep and that I have seen is that the request reaches the container. If I ngrep on the host machine I see the requests going in but no response going back. If I ngrep on the container I see the requests going in and the response going back. I've tried multiple iptables setups (with postrouting enabled, with manually forwarding ports etc) but no success. Help in any way - even debugging directions would be much appreciated. Thanks!

    Read the article

  • Proxychains, Tortunnel, Privoxy: cannot connect() to port

    - by Benjamin
    Hi all, I'm trying to do an nmap scan through tor using tortunnel, privoxy and proxychains like explained in the following video: http://vimeo.com/6238958 I'm getting rather weird results. I can successfully perform any SYN scan on any port. However as soon as I try to do connect() scans, proxychains cannot connect itself to all ports. In other words, I can perform connect() scans to port 80: proxychains nmap -P0 -A -sV www.zzz.com -p80 but not port 21: proxychains nmap -P0 -A -sV www.zzz.net -p21 I get the following error: Starting Nmap 4.62 ( http://nmap.org ) at 2010-06-02 08:34 UTC ProxyChains-2.1 (http://proxychains.sf.net) random chain (1):....127.0.0.1:5060....can't connect to..113.I2.1W1.YY:21 random chain (1):....127.0.0.1:5060....can't connect to..113.I2.1W1.YY:21 random chain (1):....127.0.0.1:5060....can't connect to..113.I2.1W1.YY:21 random chain (1):....127.0.0.1:5060....can't connect to..113.I2.1W1.YY:21 random chain (1):....127.0.0.1:5060....can't connect to..113.I2.1W1.YY:21 random chain (1):....127.0.0.1:5060....can't connect to..113.I2.1W1.YY:21 My only guess would be that the exit node I'm using does not allow connections to port 21. Would that be correct? How could I fix it? Thanks for your time.

    Read the article

  • LogMeIn style remote access to NAS drive

    - by Mere Development
    I've been asked to setup some remote access to a NAS drive. The NAS drive will sit on a VLAN inside a network that uses a Cisco 891 IS router as gateway. The charity have no SSL-VPN licenses for the Cisco. At present there are no open ports or services on the Cisco itself and ideally we would like to keep it that way for a while, hence the request for a LogMeIn style service that's initiated from inside. We need multiple user access, about 10 max. Using LogMeIn on a machine connected to the NAS would only provide screen sharing I believe, and no concurrent connections (could be wrong?) The end users need to be able to read and write files to the NAS from Mac's and PC's around the globe. Read-only access from Mobile devices would be a bonus but not absolutely necessary. This is for a charity, non-commercial, but they are willing to spend if necessary. Cisco config knowledge is at a minimum so if I can avoid upsetting that delicate device I'll be happy :) Anyone have any clever ideas? I can provide more information on request. Thanks, Ben

    Read the article

  • Can Current Backflow from Powered Hub's Adapter & cause PC Damage?

    - by SuperUserMan
    Getting this short: Can current flow from a powered USB hub's power adapter (lying 10 Meter away) back to computer via usb port and cause damage to Computer components like mobo, etc? What should be my concerns? Using a 2 Amp 5V Power adapter to power a 10m Long Active Repeater USB extension cable with 4 port HUB & plugging into PC's Front port, causes PC Chassis fan to keep running (thought slower than regular speed) Front Chassis HDD & power LED to turn on (though bit dim) may be other things which i cant detect/see at chip level, in motherboard?? All this even after PC is shut down (bit scary) More detail (in case still want to read): To run 4 High power (needing 450 mAmps) Wifi Adapters, far away from PC, Bought Active Repeater USB Extension Cable with 4 Ports & power port at far end http://www.ebay.com/itm/33FT-USB-2-0-Male-to-Female-Extension-Cable-Hub-Splitter-Adapter-with-4-USB-Port-/390846115254 Then added a locally bought 2 Amp 240V AC to 5V DC Power Adapter and plugged into USB hub which is a part of & situated at far end of a 10 Meter Active Repeater usb extension cable. Even 4 Wifi Adapters run fine (appear to) using this setup, but running chassis fan, dimly lighted Power & HDD LED, even when PC is switched off is bit scary and surely mean 5V & some current is flowing all though that 10 meter extension cable into my USB port & powering stuff. Can this cause damage? and what should be my concerns. Of course I can't switch off the power adapter (lying 10 meters away from PC) every time I switch off my PC to prevent this.

    Read the article

  • Multi-WAN bonding across different media

    - by Tom O'Connor
    I've recently been thinking again about a product that Viprinet provide, basically they've got a pair of routers, one that lives in a datacentre, Their VPN Multichannel Hub and the on-site hardware, their VPN multichannel routers They've also got a bunch of interface cards (like HWICs) for 3G, UMTS, Ethernet, ADSL and ISDN adapters. Their main spiel seems to be bonding across different media. It's something that I'd really like to use for a couple of projects, but their pricing is really quite extreme, the hub is about 1-2k, the routers are 2-6k, and the interface modules are 200-600 each. So, what I'd like to know is, is it possible with a couple of stock Cisco routers, 28xx or 18xx series, to do something similar, and basically connect a bunch of different WAN ports, but have it all presented neatly as one channel back to the internet, with seamless (or nearly) failover if one of the WAN interfaces should fail. Basically, If i got 3x 3G to ethernet modems, and each on a different network, I'd like to be able to loadbalance/bond across all of them, without having to pay Viprinet for the privilege. Does anyone know how I'd go about configuring something for myself, based around standard protocols (or vendor specific ones), but without actually having to buy the Viprinet hardware?

    Read the article

  • How can I get Windows 7 to work with two Nvidia graphics cards with different drivers?

    - by Max
    This is similar to this question, but I am using more similar cards with Windows 7. I just purchased a Zotac Nvidia GeForce 7200 GS. I have a motherboard with two PCI Express x16 slots. There is already an MSI Nvidia GeForce 8800 GTS being used as the primary card, driving two LCD monitors. I would like the Zotac to output to a TV via DVI-out. Unfortunately, when Windows detects the Zotac and installs its drivers, or I manually install them, Windows stops being able to boot up. If I remove them and re-install the MSI 8800 drivers, I can boot again, but Windows can no longer see the Zotac 7200--it shows up as a yellow triangle in Device Manager. I've read conflicting reports about this. Some people claim that Windows 7 will support multiple heterogeneous graphics card drivers, as long as they are all using the same driver API ("WDDM?"). Others say that they have to be using the exact same driver, or it won't work. Others claim that you have to use the exact same card. which is it, exactly? I know I can run the MSI 8800 in SLI if I purchase another, but I don't need that kind of power--I just need HD-out to my television. I read somewhere that running two cards in SLI precludes you from using 100% of their output ports, so I'm not sure if that's an option. I suppose I could also run two MSI 8800's without SLI, but again, that's more power than I need (and more money than I'd like to spend). Also, I don't think this exact model is even manufactured anymore. Any ideas?

    Read the article

  • Determining the Source of a Given File System Mount on Unix [migrated]

    - by phobos51594
    Background Recently I have run into a bit of a snag on my home FreeBSD server. I recently upgraded it to the latest stable release, and I have noticed some strange behavior with the /var partition. Originally, I had the system configured such that /var had its own partition with /var/run and /var/log in memory disks (/tmp, too). After the upgrade, I notice there is a new, fourth memory disk mounting directly to /var that I had not set up manually and is not in my fstab. It is only 28 megs or so in size and is causing problems when trying to update my ports collection. The ramdisk mounts atuomagically at boot and cannot be unmounted while in multi-user mode. If I drop to single user mode, I am able to unmount it without issue, however rebooting causes it to pop right back up. System specifications have been included at the end of the post. Question Is there any way to determine exactly what is mounting a given memory disk (or any filesystem, for that matter) after it has been mounted? Alternately, does anybody have any ideas what might have caused the new /var ramdisk to pop up? System Specification # uname -a FreeBSD sarge 9.1-PRERELEASE FreeBSD 9.1-PRERELEASE #0: Thu Nov 22 14:02:13 PST 2012 donut@sarge:/usr/obj/usr/src/sys/GENERIC i386 # df Filesystem 1K-blocks Used Avail Capacity Mounted on /dev/da0s1a 515612 410728 63636 87% / devfs 1 1 0 100% /dev /dev/da0s1d 515612 287616 186748 61% /var /dev/da0s1e 6667808 2292824 3841560 37% /usr /dev/md0 63004 32 57932 0% /tmp /dev/md1 3484 8 3200 0% /var/run /dev/md2 31260 8 28752 0% /var/log /dev/md3 31260 512 28248 2% /var <-- This # cat /etc/fstab # Device Mountpoint FStype Options Dump Pass# /dev/da0s1a / ufs rw,noatime 1 1 /dev/da0s1d /var ufs rw,noatime 2 2 /dev/da0s1e /usr ufs rw,noatime 2 2 md /tmp mfs rw,-s64M,noatime 0 0 md /var/run mfs rw,-s4M,noatime 0 0 md /var/log mfs rw,-s32M,noatime 0 0 Thank you in advance for any assistance.

    Read the article

  • What program sent which packet to the network [closed]

    - by Erik Johansson
    I would like to have a tcpdump like program that shows which program sent a specific packet, instead of just getting the port number. This is a generic problem I've had on and off sometimes when you have and old tcpdump file lying around you have no way to find what program was sending that data.. The solution in how i can identify which process is making UDP traffic on linux ? is an indication that I can solve this with auditd, dTrace, OProfile or SystemTap, but doesn't show how to do it. I.e. it doesn't show the source port of the program calling bind().. The problem I had was strange UDP packets, and since those ports are so short lived it took me a while to solve this issue. I solved this by running an ugly hack similar to: while true; date +%s.%N;netstat -panut;done So either a method better than this hack, a replacement for tcpdump, or some way to get this info from the kernel so I can patch tcpdump. EDIT: This was asked on superuser "tracking what programs sends to net", no good solution though.

    Read the article

  • Are there any tests I can run on a network to simulate 100 heavy network users?

    - by marc.gayle
    I will be hosting a Ruby on Rails workshop at a small hotel in the near future, and while they have 'Wifi' everywhere on the property, and the property normally hosts 150 - 300 people, I am not 100% confident that they have hosted 150 tech people that tend to have heavy web surfing habits/needs. Their tech department is also 1 or 2 guys. Are there any automated tests I can download and run from my laptop, on the network, that would simulate 100 'heavy users' on the network at the same time? Their broadband pipe is a 15mbps cable connection. Would that suffice for the general surfing needs of 100 - 150 techies? I know all it takes is 1 or 2 bit torrenters to kill the entire network, but assuming we can at the very least block those ports or encourage the attendees not to file share on the network, would that speed suffice for general surfing needs? What are good resources online that would allow me to quickly get up to speed on the IT related issues, so that I can ask their sysadmins the right questions? Edit: Note that I am fairly technical, so assume I can get up to speed quickly even with technical manuals, etc.

    Read the article