  • Oracle OpenWorld Session: “Business Driven Development with BPM: Lessons from the Real World”

    - by Ajay Khanna
    One of key values that BPM promises is “Business Empowerment”. People closest to the processes, who participate in the process every day, are the ones who know most about the process. These are the people who run day-to-day operations, people who triage customer issues, people who envision improvements and innovations. It is, therefore, imperative that when a company decides to use BPM technology to automate their business processes, business people take the driver’s seat. BPM is not an IT only project. Oracle BPM suite has been designed keeping this core tenet of BPM, Business Empowerment, in mind. The result is business user centered design of Process Composer. Process Composer is designed to let business users document their processes, analyze them using simulation, create web forms, specify business rules and even run them in testing mode using process player, to see if the designed process meets their needs. This does not mean that IT has no role in this process. In fact, Oracle BPM Suite has made it very easy for Business and IT to collaborate. The same process can be shared among business, and IT stakeholders and each can collaborate to create model-driven, process based executable applications. A process may need to integrate with multiple systems via various mechanisms, and IT leads system and data integration effort. IT helps fine tune the performance of process applications and ensures that the deployment of process application meets scalability and failover standards. In this session, we saw Harish Gaur and Satya Narayanan from Oracle demonstrate roles Business and IT play in BPM projects and how Oracle BPM Suite enables business and IT collaboration to design and automate process based applications. They also discussed real life customer stories. Some key takeaways from this session: There are no IT projects, only business initiatives, requiring IT support Identify high impact processes – critical, better BPM ROI Identify key metrics to measure process performance Align business with IT layer

    Read the article

  • Releasing Excel after using Interop

    - by figus
    Hi everyone I've read many post looking for my answer, but all are similar to this: http://stackoverflow.com/questions/1610743/reading-excel-files-in-vb-net-leaves-excel-process-hanging My problem is that I don't quit the app... The idea is this: If a User has Excel Open, if he has the file I'm interested in open... get that Excel instance and do whatever I want to do... But I don't to close his File after I'm done... I want him to keep working on it, the problem is that when he closes Excel... The process keeps running... and running... and running after the user closes Excel with the X button... this is how I try to do it This piece is used to know if he has Excel open, and in the For I check for the file name I'm interested in. Try oApp = GetObject(, "Excel.Application") libroAbierto = True For Each libro As Microsoft.Office.Interop.Excel.Workbook In oApp.Workbooks If libro.Name = EquipoASeccionIdSeccion.Text & ".xlsm" Then Exit Try End If Next libroAbierto = False Catch ex As Exception oApp = New Microsoft.Office.Interop.Excel.Application End Try here would be my code... if he hasn't Excel open, I create a new instance, open the file and everything else. My code ends with this: If Not libroAbierto Then libroSeccion.Close(SaveChanges:=True) oApp.Quit() Else oApp.UserControl = True libroSeccion.Save() End If System.Runtime.InteropServices.Marshal.FinalReleaseComObject(libroOriginal) System.Runtime.InteropServices.Marshal.FinalReleaseComObject(libroSeccion) System.Runtime.InteropServices.Marshal.FinalReleaseComObject(origen) System.Runtime.InteropServices.Marshal.FinalReleaseComObject(copiada) System.Runtime.InteropServices.Marshal.FinalReleaseComObject(oApp) libroOriginal = Nothing libroSeccion = Nothing oApp = Nothing origen = Nothing copiada = Nothing nuevosGuardados = True So you can see that, if I opened the file, I call oApp.Quit() and everything else and the Excel Process ends after a few seconds (maybe 5 aprox.) BUT if I mean the user to keep the file open (not calling Quit()), Excel process keeps running after the user closes Excel with the X button. Is there any way to do what I try to do?? Control a open instance of excel and releasing everything so when the user closes it with the X button, the Excel Process dies normally??? Thanks!!!

    Read the article

  • create an independent hidden process

    - by Jessica
    I'm creating an application with its main window hidden by using the following code: STARTUPINFO siStartupInfo; PROCESS_INFORMATION piProcessInfo; memset(&siStartupInfo, 0, sizeof(siStartupInfo)); memset(&piProcessInfo, 0, sizeof(piProcessInfo)); siStartupInfo.cb = sizeof(siStartupInfo); siStartupInfo.dwFlags = STARTF_USESHOWWINDOW | STARTF_FORCEOFFFEEDBACK | STARTF_USESTDHANDLES; siStartupInfo.wShowWindow = SW_HIDE; if(CreateProcess(MyApplication, "", 0, 0, FALSE, 0, 0, 0, &siStartupInfo, &piProcessInfo) == FALSE) { // blah return 0; } Everything works correctly except my main application (the one calling this code) window loses focus when I open the new program. I tried lowering the priority of the new process but the focus problem is still there. Is there anyway to avoid this? furthermore, is there any way to create another process without using CreateProcess (or any of the API's that call CreateProcess like ShellExecute)? My guess is that my app is losing focus because it was given to the new process, even when it's hidden. To those of you curious out there that will certainly ask the usual "why do you want to do this", my answer is because I have a watchdog process that cannot be a service and it gets started whenever I open my main application. Satisfied? Thanks for the help. Code will be appreciated. Jess.

    Read the article

  • ATI Radeon HD with Catalyst driver stuck mirroring screens

    - by Mike Axiak
    In 11.10 I replaced my aging Nvidia card with a new Radeon HD 6970 card. The single card has two DVI output ports which I've connected to two monitors. I installed Catalyst version 11.9 and I cannot get multiple monitors set up the way I want. I tried: $ sudo amdcccle and setting the mode to single desktop multiple monitors and whenever I do that Unity crashes and I get back to the login screen. Nothing shows up in the Xorg.*.log files for me to post here. There's only one card so I don't think xinerama would be any help here. Anyone have any ideas? EDIT: Here's my xorg.conf file: Section "ServerLayout" Identifier "aticonfig Layout" Screen 0 "aticonfig-Screen[0]-0" 0 0 EndSection Section "Module" EndSection Section "Monitor" Identifier "aticonfig-Monitor[0]-0" Option "VendorName" "ATI Proprietary Driver" Option "ModelName" "Generic Autodetecting Monitor" Option "DPMS" "true" EndSection Section "Monitor" Identifier "0-DFP3" Option "VendorName" "ATI Proprietary Driver" Option "ModelName" "Generic Autodetecting Monitor" Option "DPMS" "true" Option "PreferredMode" "1280x1024" Option "TargetRefresh" "60" Option "Position" "0 0" Option "Rotate" "normal" Option "Disable" "false" EndSection Section "Monitor" Identifier "0-CRT1" Option "VendorName" "ATI Proprietary Driver" Option "ModelName" "Generic Autodetecting Monitor" Option "DPMS" "true" Option "PreferredMode" "1280x1024" Option "TargetRefresh" "75" Option "Position" "0 0" Option "Rotate" "normal" Option "Disable" "false" EndSection Section "Device" Identifier "aticonfig-Device[0]-0" Driver "fglrx" Option "Monitor-DFP3" "0-DFP3" Option "Monitor-CRT1" "0-CRT1" BusID "PCI:5:0:0" EndSection Section "Device" Identifier "amdcccle-Device[5]-1" Driver "fglrx" Option "Monitor-DFP3" "0-DFP3" BusID "PCI:5:0:0" Screen 1 EndSection Section "Screen" Identifier "aticonfig-Screen[0]-0" Device "aticonfig-Device[0]-0" DefaultDepth 24 SubSection "Display" EndSubSection EndSection Section "Screen" Identifier "amdcccle-Screen[5]-1" Device "amdcccle-Device[5]-1" DefaultDepth 24 SubSection "Display" Viewport 0 0 Depth 24 EndSubSection EndSection

    Read the article

  • What does it mean for an OS to "execute within user processes"? Do any modern OS's use that approach

    - by Chris Cooper
    I have recently become interested in operating system, and a friend of mine lent me a book called Operating Systems: Internals and Design Principles (I have the third edition), published in 1998. It's been a very interesting book so far, but I have come to the part dealing with process control, and it's using UNIX System V as one of its examples of an operating system that executes within user processes. This concept has struck me as a little strange. First of all, does this mean that OS instructions and data are stored in each user of the processes? Probably not, because that would be an absurdly redundant scheme. But if not, then what does it mean to "execute within" a user process? Do any modern operating systems use this approach? It seems much more logical to have the operating system execute as its own process, or even independently of all processes, if you're short on memory. All the inter-accessiblilty of process data required for this layout seems to greatly complicate things. (But maybe that's just because I don't quite get the concept ;D) Here is what the book says: "Execution within User Processes: An alternative that is common with operation systems on smaller machines is to execute virtually all operating system software in the context of a user process. ... "

    Read the article

  • Maximizing after moving RDC window between different size monitors

    - by msorens
    My Win7 system has two monitors of different sizes. When I open a Remote Desktop Connection on one monitor set to use full screen, both the RDC window and the remote system's desktop fills the monitor. If I then move the window onto my second monitor (1-Restore Down button to make it movable; 2-Drag window to other monitor; 3-Maximize button to fill monitor) the RDC window fills the monitor, but the remote system's desktop remains the same size it was before. Thus, if I move from the larger to the smaller monitor I have scrollbars to see the whole remote desktop, while if I move from the smaller to the larger monitor the remote desktop occupies only a portion of the monitor. My workaround is to close the RDC window completely then re-establish it on the other monitor. Is there a way to avoid this overhead and just resize the remote desktop to fit?

    Read the article

  • How to catch exceptions from processes in C#

    - by kitofr
    I all... I have an acceptance runner program here that looks something like this: public Result Run(CommandParser parser) { var result = new Result(); var watch = new Stopwatch(); watch.Start(); try { _testConsole.Start(); parser.ForEachInput(input => { _testConsole.StandardInput.WriteLine(input); return _testConsole.TotalProcessorTime.TotalSeconds < parser.TimeLimit; }); if (TimeLimitExceeded(parser.TimeLimit)) { watch.Stop(); _testConsole.Kill(); ReportThatTestTimedOut(result); } else { result.Status = GetProgramOutput() == parser.Expected ? ResultStatus.Passed : ResultStatus.Failed; watch.Stop(); } } catch (Exception) { result.Status = ResultStatus.Exception; } result.Elapsed = watch.Elapsed; return result; } the _testConsole is an Process adapter that wraps a regular .net process into something more workable. I do however have a hard time to catch any exceptions from the started process (i.e. the catch statement is pointless here) I'm using something like: _process = new Process { StartInfo = { FileName = pathToProcess, UseShellExecute = false, CreateNoWindow = true, RedirectStandardInput = true, RedirectStandardOutput = true, RedirectStandardError = true, Arguments = arguments } }; to set up the process. Any ideas?

    Read the article

  • Is there a way to force lubuntu screen resolution?

    - by za1
    I have a Dell Inspiron 4000, 900 Mhz Pentium III, 192 MB RAM,10.1 GB disk running Lubuntu 12.04. When I start the computer, and I check the display resolution, Monitor Settings claims that the max resolution is 1024x768. I then connected another monitor I had lying around, rebooted, and now the laptop monitor looks normal,and monitor settings claims that 1280x1024 is the max resolution (it is) and the other monitor doesn't turn on. (black screen) The external monitor is not broken. Is there a way to, without the external monitor, force the laptop monitor resolution to 1280x1024? (The following is another question) - How can you run commands automatically at startup? Specifically "xinput 18 118 0" (without quotes) The first question is important, I can live with typing the second one at every boot. Thanks

    Read the article

  • Starting a process synchronously, and "streaming" the output

    - by Benjol
    I'm looking at trying to start a process from F#, wait till it's finished, but also read it's output progressively. Is this the right/best way to do it? (In my case I'm trying to execute git commands, but that is tangential to the question) let gitexecute (logger:string->unit) cmd = let procStartInfo = new ProcessStartInfo(@"C:\Program Files\Git\bin\git.exe", cmd) // Redirect to the Process.StandardOutput StreamReader. procStartInfo.RedirectStandardOutput <- true procStartInfo.UseShellExecute <- false; // Do not create the black window. procStartInfo.CreateNoWindow <- true; // Create a process, assign its ProcessStartInfo and start it let proc = new Process(); proc.StartInfo <- procStartInfo; proc.Start() |> ignore // Get the output into a string while not proc.StandardOutput.EndOfStream do proc.StandardOutput.ReadLine() |> logger What I don't understand is how the proc.Start() can return a boolean and also be asynchronous enough for me to get the output out of the while progressively. Unfortunately, I don't currently have a large enough repository - or slow enough machine, to be able to tell what order things are happening in...

    Read the article

  • change application windows style

    - by Suriyan Suresh
    I start IE as a process and then i would like to change the following properties of a application. remove title bar, toolbar of a application(if IE) set top,left location and size through c# prevent process from minimizing , i have used the following code but had no luck(find the handle of the process and then pass it to below function) public void SetFormOnDesktop(int hwnd) { int hwndf = hwnd; IntPtr hwndParent = FindWindow("ProgMan", null); SetParent(hwndf, hwndParent); } EDIT 1: Is it possible to prevent IE context menu and prevent it from showing on taskbar

    Read the article

  • Running a process at the Windows 7 Welcome Screen

    - by peelman
    So here's the scoop: I wrote a tiny C# app a while back that displays the hostname, ip address, imaged date, thaw status (we use DeepFreeze), current domain, and the current date/time, to display on the welcome screen of our Windows 7 lab machines. This was to replace our previous information block, which was set statically at startup and actually embedded text into the background, with something a little more dynamic and functional. The app uses a Timer to update the ip address, deepfreeze status, and clock every second, and it checks to see if a user has logged in and kills itself when it detects such a condition. If we just run it, via our startup script (set via group policy), it holds the script open and the machine never makes it to the login prompt. If we use something like the start or cmd commands to start it off under a separate shell/process, it runs until the startup script finishes, at which point Windows seems to clean up any and all child processes of the script. We're currently able to bypass that using psexec -s -d -i -x to fire it off, which lets it persist after the startup script is completed, but can be incredibly slow, adding anywhere between 5 seconds and over a minute to our startup time. We have experimented with using another C# app to start the process, via the Process class, using WMI Calls (Win32_Process and Win32_ProcessStartup) with various startup flags, etc, but all end with the same result of the script finishing and the info block process getting killed. I tinkered with rewriting the app as a service, but services were never designed to interact with the desktop, let alone the login window, and getting things operating in the right context never really seemed to work out. So for the question: Does anybody have a good way to accomplish this? Launch a task so that it would be independent of the startup script and run on top of the welcome screen?

    Read the article

  • Killing a subprocess including its children from python

    - by user316664
    Hi, I'm using the subprocess module on python 2.5 to spawn a java program (the selenium server, to be precise) as follows: import os import subprocess display = 0 log_file_path = "/tmp/selenium_log.txt" selenium_port = 4455 selenium_folder_path = "/wherever/selenium/lies" env = os.environ env["DISPLAY"] = ":%d.0" % display command = ["java", "-server", "-jar", 'selenium-server.jar', "-port %d" % selenium_port] log = open(log_file_path, 'a') comm = ' '.join(command) selenium_server_process = subprocess.Popen(comm, cwd=selenium_folder_path, stdout=log, stderr=log, env=env, shell=True) This process is supposed to get killed once the automated tests are finished. I'm using os.kill to do this: os.killpg(selenium_server_process.pid, signal.SIGTERM) selenium_server_process.wait() This does not work. The reason is that the shell subprocess spawns another processfor the java program, and the pid of that process is unknown to my python code. I've tried killing the process group with os.killpg, but that kills also the python process which runs this code in the first place. Setting shell to false, thus avoiding the java program to run inside a shell environment, is also out of the question, due to other reasons. Does anyone have an idea how I can kill the shell and any other processes generated by it? Cheers, Ulas

    Read the article

  • Slowing process creation under Java?

    - by oconnor0
    I have a single, large heap (up to 240GB, though in the 20-40GB range for most of this phase of execution) JVM [1] running under Linux [2] on a server with 24 cores. We have tens of thousands of objects that have to be processed by an external executable & then load the data created by those executables back into the JVM. Each executable produces about half a megabyte of data (on disk) that when read right in, after the process finishes, is, of course, larger. Our first implementation was to have each executable handle only a single object. This involved the spawning of twice as many executables as we had objects (since we called a shell script that called the executable). Our CPU utilization would start off high, but not necessarily 100%, and slowly worsen. As we began measuring to see what was happening we noticed that the process creation time [3] continually slows. While starting at sub-second times it would eventually grow to take a minute or more. The actual processing done by the executable usually takes less than 10 seconds. Next we changed the executable to take a list of objects to process in an attempt to reduce the number of processes created. With batch sizes of a few hundred (~1% of our current sample size), the process creation times start out around 2 seconds & grow to around 5-6 seconds. Basically, why is it taking so long to create these processes as execution continues? [1] Oracle JDK 1.6.0_22 [2] Red Hat Enterprise Linux Advanced Platform 5.3, Linux kernel 2.6.18-194.26.1.el5 #1 SMP [3] Creation of the ProcessBuilder object, redirecting the error stream, and starting it.

    Read the article

  • Apache Connection vs. Request

    - by user101570
    I apologize in advance if this is a basic question, but I am quite confused after reading the Apache documentation and other tutorials. Does a single Apache prefork process serve all HTTP requests for a given client? That's what I thought, but when I reduce maxclients down to a low number, my page load times go to a crawl. This despite the fact I'm the only client on the server in question. This would suggest each process serves a single HTTP request at a time, rather than serving all requests within the TimeOut window. So if a single webpage requires 15 HTTP requests to load fully, do I require 15 prefork Apache processes to optimally serve it?

    Read the article

  • Pass variables between separate instances of ruby (without writing to a text file or database)

    - by boulder_ruby
    Lets say I'm running a long worker-script in one of several open interactive rails consoles. The script is updating columns in a very, very, very large table of records. I've muted the ActiveRecord logger to speed up the process, and instruct the script to output some record of progress so I know how roughly how long the process is going to take. That is what I am currently doing and it would look something like this: ModelName.all.each_with_index do |r, i| puts i if i % 250 ...runs some process... r.save end Sometimes its two nested arrays running, such that there would be multiple iterators and other things running all at once. Is there a way that I could do something like this and access that variable from a separate rails console? (such that the variable would be overwritten every time the process is run without much slowdown) records = ModelName.all $total = records.count records.each_with_index do |r, i| $i = i ...runs some process... r.save end meanwhile mid-process in other console puts "#{($i/$total * 100).round(2)}% complete" #=> 67.43% complete I know passing global variables from one separate instance of ruby to the next doesn't work. I also just tried this to no effect as well unix console 1 $X=5 echo {$X} #=> 5 unix console 2 echo {$X} #=> "" Lastly, I also know using global variables like this is a major software design pattern no-no. I think that's reasonable, but I'd still like to know how to break that rule if I'd like. Writing to a text file obviously would work. So would writing to a separate database table or something. That's not a bad idea. But the really cool trick would be sharing a variable between two instances without writing to a text file or database column. What would this be called anyway? Tunneling? I don't quite know how to tag this question. Maybe bad-idea is one of them. But honestly design-patterns isn't what this question is about.

    Read the article

  • Automatically kill processes that over time uses 95%+ of resources? Ubuntu

    - by data_jepp
    I don't know about you're computer but when mine is working properly no process is sucking 95%+ over time. I would like to have some failsafe that kills any processes behaving like that. This comes to mind because when I woke up this morning my laptop had been crunching all night long on a stray chromium child process. This can probably be done as a cron job, but before I make it a full time job creating something like this I'd thought I should check here. :) I hate reinventing the wheel.

    Read the article

  • Nagios Creating lots of zombie process

    - by pradeepchhetri
    In my monitoring box, I have lots of zombie process created by nagios and they gets remove quickly also. I am using active checks to perform monitoring of my servers. I accumulated the defunct processes created using the following command: $ top -d 0.25 -b -n 20 > topout.txt This collected the output of top with 0.25s delay 20 times. I did grep on the topout.txt for the defunct process. $ cat topout.txt | grep defunct I get the following output. 8957 nagios 20 0 0 0 0 Z 6.0 0.0 0:00.02 nagios <defunct> 8951 nagios 20 0 0 0 0 Z 3.0 0.0 0:00.01 nagios <defunct> 8954 nagios 20 0 0 0 0 Z 3.0 0.0 0:00.01 nagios <defunct> 8945 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 8946 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 8980 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9000 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.00 nagios <defunct> 9024 nagios 20 0 0 0 0 Z 7.0 0.0 0:00.02 nagios <defunct> 9025 nagios 20 0 0 0 0 Z 3.5 0.0 0:00.01 nagios <defunct> 9040 nagios 20 0 0 0 0 Z 3.1 0.0 0:00.01 nagios <defunct> 9086 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9087 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9123 nagios 20 0 0 0 0 Z 6.1 0.0 0:00.02 nagios <defunct> 9126 nagios 20 0 0 0 0 Z 3.0 0.0 0:00.01 nagios <defunct> 9131 nagios 20 0 0 0 0 Z 3.0 0.0 0:00.01 nagios <defunct> 9091 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.05 nagios <defunct> 9111 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9119 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9118 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9151 nagios 20 0 0 0 0 Z 2.9 0.0 0:00.02 nagios <defunct> 9153 nagios 20 0 0 0 0 Z 2.9 0.0 0:00.02 nagios <defunct> 9150 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9164 nagios 20 0 0 0 0 Z 3.5 0.0 0:00.02 nagios <defunct> 9171 nagios 20 0 0 0 0 Z 3.5 0.0 0:00.02 nagios <defunct> 9154 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9156 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9163 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9167 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9178 nagios 20 0 0 0 0 Z 3.8 0.0 0:00.02 nagios <defunct> 9174 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9179 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> 9182 nagios 20 0 0 0 0 Z 0.0 0.0 0:00.01 nagios <defunct> Can somebody help me in finding out the reason of these zombie processes and how i can prevent these zombie processes ?

    Read the article

  • Laptop Asus P50IJ with Intel 4500M GMA output going to a Dell 1907FP external monitor will not allow

    - by ProfessionalAmateur
    Hello - I just purchased an Asus P50IJ-X2 laptop which has a Intel GMA 4500M video card running Windows7. At work I output this laptop to a Dell 1907FP LCD which has a maximum resolution of 1280x1024. Not matter what I do the Windows will not allow the laptop to set a resolution higher than 1024x768 to this LCD monitor. Ive even gone to the extent of downloading PowerStrip (I'd post a link but Im new and can only enter 1 url, if you google for powerstrip its the first option) to create a custom driver for my monitor thinking Windows was having a hard time seeing the available resolutions it would accept. However, powerstrip read the registery and properly sees the monitor and what its capable of so Im now at a complete loss as to why Windows7 will not allow me to set/use a 1280x1024 resolution for this external monitor (as my last laptop did running Vista). The Intel documentation (http://software.intel.com/en-us/articles/quick-reference-guide-to-intel-integrated-graphics/) indicates that the GMA 4500M should be able to run up to a 2560x1600 max res. The Dell 1907FP specification states it can run up to a 1280x1024 res. But no matter what the computer will not allow me to set higher than a 1024x768. I'm completely baffled but I would really like to be able to output this laptop to a reasonable resolution, 1024x768 makes me feel like I'm using my mom's computer. Any help would be greatly appreciated! Here are some attached images (I apologize for the links, being new I cannot post images) that should help explain this better: Image 1 - This image is from powerstrip which shows the monitors max accepted resolution and at the top right the max res my PC currently allows. (http://imgur.com/agrno.png) Image 2 - This shows my Windows7 resolution picker. (http://imgur.com/3nv6q.png) Image 3 - The 'List all modes' option taken from the Screen Resolution Advanced Settings List All Modes. (http://imgur.com/AMREh.png) Image 4 - Monitor information from registry read by powerstrip, this shows the laptop is able to read the necessary info from the LCD monitor. (http://imgur.com/hUX4D.png)

    Read the article

  • There's a stray current flowing from my monitor through the VGA cable to the PC. Is this safe?

    - by EApubs
    I have two monitors in my machine. One is an old LCS samsung monitor. Recently, I started to hear a small hum in my speakers (subwoofer) and replaced them. The new one also got the issues then I found our that its a grounding issue. I unplugged the PC's power chord. The monitor is still switched on. When I checked, there's current in the earth pin (ground pin). When I unplug the monitor, there's no current and the speaker is normal. Now, I have moved that monitor to my dad's machine and took his monitor. My question is, is it a big issues? The house's earthing system is working and its grounding the current. I won't feel it if I touch the machine like in many other cases. But still, is it good to keep that monitor attached to my machine? Can it harm the computer? What should I do?

    Read the article

  • 2560 x 1600 screen resolution not available when a second monitor is attached.

    - by sgmoore
    I am running Windows 7 (64-bit edition) and have a 30" Dell 3007WFP monitor which runs at a screen resolution of 2560 x 1600. This works perfectly until I try to connect a second monitor, and then the screen resolution on the main monitor immediately drops to 1280x800 and I can't change it back up to the correct resolution until I disconnect the second monitor. The graphics card is a Nvidia Quadro FX 370. This has a dual link DVI connector (to which the 30" is connected) and a single link DVI connector. The second monitor can run at 1920x1080 and is connected using a VGA to DVI connector. Note, it does not seem to matter whether the second monitor is running at 1920x1080 or even at 800x600. Windows reports Total Available Graphics Memory: 3839MB Dedicated Video Memory: 256MB System Video Memory: 0MB Shared System Memory: 3583MB Does anyone know if this a limitation with the video card, memory, drivers, connectors or something else? If this is a limitation with the video card, can anyone recommend a PCI Express 16 card that would support at least this setup, but preferably support two 30" monitors both running 2560 x 1600. (I'm not into gaming etc, so it doesn't need to be very powerful)

    Read the article

  • System.ComponentModel.Win32Exception Message: Not enough storage is available to process this comman

    - by george9170
    short of restarting our server, is there anyway we can get this memory released and our website up and running. Below is a trace from the event viewer An unhandled exception occurred and the process was terminated. Application ID: /LM/W3SVC/17/ROOT Process ID: 14352 Exception: System.ComponentModel.Win32Exception Message: Not enough storage is available to process this command StackTrace: at MS.Win32.UnsafeNativeMethods.RegisterClassEx(WNDCLASSEX_D wc_d) at MS.Win32.HwndWrapper..ctor(Int32 classStyle, Int32 style, Int32 exStyle, Int32 x, Int32 y, Int32 width, Int32 height, String name, IntPtr parent, HwndWrapperHook[] hooks) at MS.Win32.MessageOnlyHwndWrapper..ctor() at System.Windows.Threading.Dispatcher..ctor() at System.Windows.Threading.Dispatcher.get_CurrentDispatcher() at ISC.MapDotNetServer.MapPrintSupport.BaseTileRequestorResolver.b__0() at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart()

    Read the article

  • WCF Windows Service Monitor and process emails

    - by acadia
    Hello, I need your suggestions in solving this issue. Here is the requirement. We have a Microsoft Exchange server and we have a service email account [email protected]. We have scanners all owner the company when a user scans a document and email is sent to [email protected] as attachment. Now I need to write a Windows service which needs to monitor that email account and whenever an email is received, read the attachement and store it in the database. My question is, is it possible to do something of this sort? Any suggestions greatly appreciated. Thanks

    Read the article

  • Android: How to receive process signals in an activity to kill child process ?

    - by user355993
    My application calls Runtime.exec() to launch an executable in a separate process at start up time. I would like this child process to get killed when the parent activity exits. Now I can use onDestroy() to handle regular cases, but not "Force quit", shutdowns from DDMS, or kill from the console since those don't run onDestroy(). The addShutdownHandler() does not seem to be invoked in these cases either. Is there any other hook or signal handler that informs my activity that it's about to get terminated ? As an alternative is there a way to have the system automatically kill the child process when the parent dies ?

    Read the article

  • C# - Launch Invisible Process (CreateNoWindow & WindowStyle not working?)

    - by Chad
    I have 2 programs (.exe) which I've created in .NET. We'll call them the Master and the Worker. The Master starts 1 or more Workers. The Worker will not be interacted with by the user, but it is a WinForms app that receives commands and runs WinForms components based on the commands it receives from the Master. I want the Worker app to run completely hidden (except showing up in the Task Manager of course). I thought that I could accomplish this with the StartInfo.CreateNoWindow and StartInfo.WindowStyle properties, but I still see the Client.exe window and components in the form. However, it doesn't show up in the taskbar. Process process = new Process { EnableRaisingEvents = true, StartInfo = { CreateNoWindow = true, WindowStyle = ProcessWindowStyle.Hidden FileName = "Client.exe", UseShellExecute = false, ErrorDialog = false, } }; What do I need to do to let Client.exe run, but not show up?

    Read the article

  • Accessing one process's memory contents from another module

    - by Fangkai Yang
    I am developing a virtual device driver such that the user can write to the driver a process' pid and a virtual address, and the module will use these two values to get the memory contents of the target process. I am wondering if there is any easy functions that can fetch user page's data at this virtual address. I have tried get_user but this is not possible because the modules executing get_user at another process's context. I also tried to use ptrace_readdata, however, it seems that the file at /kernel/ptrace.c leaves a function access_process_vm undefined and also I don't know how to compile the source code of my module with this file (the linker seaches file in /linux/include by default). I am wondering if there are any other solutions...

    Read the article