Search Results

Search found 3223 results on 129 pages for 'maximum'.

Page 91/129 | < Previous Page | 87 88 89 90 91 92 93 94 95 96 97 98  | Next Page >

  • FTP Server with advanced features

    - by Nikolas Sakic
    Hi, We supply zone-files to our customers. Some zone files are big about 300MB and some are quite small, maybe like 1MB. We had this issue that someone setup a script to continually download the file. Imagine downloading 300MB file a few hundred times a day. Since, we don't have packet-shaper to throttle the traffic, we need to upgrade ftp server and use add-on modules to limit the download somehow. We currently use proftpd server. Also note that there are different users for different domains - say, if you want to download zone file for .INFO domain, then you use a particular user. That user can't download any other zone's file. This is what we are looking for: Have maximum of 400MB download per user per day. Or even have different download limit for different users per day. Have one connection per user at any time. Max # of connection (non-simultaneous) per user per day is 5. Anyone trying to exceed that gets banned for 24 hours. Has anyone used FTP server with similar restrictions above? Does anyone have any ideas where I can start? Any help would be appreciated. Thanks. -N

    Read the article

  • Strange battery behavior on laptop

    - by EpsilonVector
    My laptop is behaving rather strangely lately, and I was hoping to get some idea as to what may be causing such symptoms. The problem: When charging, very minute or so it loses connectivity with the AC adapter for a split second, and regains it back immediately. When this happens the little light that indicates the computer is plugged in does flicker off and back on, but I checked the adapter by replacing the battery on my laptop, and this indeed solves the problem, so it is probably the battery which is at fault, not the adapter (I also tried to move the adapter's wire around just to make sure it had nothing to do with torn wires). I suppose that the obvious solution is to get a new battery, but as far as battery defects go- this is a rather strange one; it loses connection with the adapter, but still powers the computer, and changing the power setting to a balanced plan (was maximum performance) seem to have solved the problem too. Is there a chance this is not simply the battery, but some kind of other electronic defect? And if not, what can cause it to behave so strangely? PS I tried to recalibrate it- didn't help.

    Read the article

  • Triple monitor setting in Linux with USB-HDMI adapter

    - by Oscar Carballal
    I'm trying to set up a triple monitor desktop at my office using Fedora 17, but it seems impossible, let me explain the setting: Laptop ASUS K53SD with 2 graphic cards, Intel and nVidia (Screen controled by Intel card) 24" Full HD monitor connected to the HDMI output (controlled by Intel card) 23" Full HD monitor connected to an USB-HDMI adapter (via framebuffer in /dev/fb2, apparently) VGA output (not used) controlled by nVidia card First of all, the USB-HDMI adapter works perfectly, it gives me a green screen (which means the communication is OK) and I can make it work if I set up a single monitor setting via framebuffer in Xorg. Here I leave the page where I got the instructions: http://plugable.com/2011/12/23/usb-graphics-and-linux Now I'm trying to set up the the two main monitors (laptop and 24") with the intel driver and the 23" with the framebuffer, but the most succesful configuration I get is the two main monitors working and the third disconnected. Do you have any idea what can I do to make this work? Here I leave my xRandr output and my Xorg conf: -> xrandr Screen 0: minimum 320 x 200, current 3286 x 1080, maximum 8192 x 8192 LVDS1 connected 1366x768+0+0 (normal left inverted right x axis y axis) 344mm x 193mm 1366x768 60.0*+ 1024x768 60.0 800x600 60.3 56.2 640x480 59.9 VGA2 disconnected (normal left inverted right x axis y axis) HDMI1 connected 1920x1080+1366+0 (normal left inverted right x axis y axis) 531mm x 299mm 1920x1080 60.0*+ 50.0 25.0 30.0 1680x1050 59.9 1680x945 60.0 1400x1050 74.9 59.9 1600x900 60.0 1280x1024 75.0 60.0 1440x900 75.0 59.9 1280x960 60.0 1366x768 60.0 1360x768 60.0 1280x800 74.9 59.9 1152x864 75.0 1280x768 74.9 60.0 1280x720 50.0 60.0 1440x576 25.0 1024x768 75.1 70.1 60.0 1440x480 30.0 1024x576 60.0 832x624 74.6 800x600 72.2 75.0 60.3 56.2 720x576 50.0 848x480 60.0 720x480 59.9 640x480 72.8 75.0 66.7 60.0 59.9 720x400 70.1 DP1 disconnected (normal left inverted right x axis y axis) 1920x1080_60.00 60.0 The Xorg file: # Xorg configuration file for using a tri-head display Section "ServerLayout" Identifier "Layout0" Screen 0 "HDMI" 0 0 Screen 1 "USB" RightOf "HDMI" Option "Xinerama" "on" EndSection ########### MONITORS ################ Section "Monitor" Identifier "USB1" VendorName "Unknown" ModelName "Acer 24as" Option "DPMS" EndSection Section "Monitor" Identifier "HDMI1" VendorName "Unknown" ModelName "Acer 23SH" Option "DPMS" EndSection ########### DEVICES ################## Section "Device" Identifier "Device 0" Driver "intel" BoardName "GeForce" BusID "PCI:0:02:0" Screen 0 EndSection Section "Device" Identifier "USB Device 0" driver "fbdev" Option "fbdev" "/dev/fb2" Option "ShadowFB" "off" EndSection ############## SCREENS ###################### Section "Screen" Identifier "HDMI" Device "Device 0" Monitor "HDMI1" DefaultDepth 24 SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "USB" Device "USB Device 0" Monitor "USB1" DefaultDepth 24 SubSection "Display" Depth 24 EndSubSection EndSection

    Read the article

  • Ext3 fs: Block bitmap for group 1 not in group (block 0). is fs dead?

    - by ip
    My company has a server with one big partition with Mysql database and php files. Now this partition seems to be corrupted, as reported from kernel messages when I tried to mount it manually: [329862.817837] EXT3-fs error (device loop1): ext3_check_descriptors: Block bitmap for group 1 not in group (block 0)! [329862.817846] EXT3-fs: group descriptors corrupted! I've tried to recovery it running tools from a PLD livecd. These are the tools I have tested: - e2retrieve - testdisk - photorec - dd_rescue/dd_rhelp - ddrescue - fsck.ext2 - e2salvage without any success. dumpe2fs 1.41.3 (12-Oct-2008) Filesystem volume name: /dev/sda3 Last mounted on: <not available> Filesystem UUID: dd51610b-6de0-4392-a6f3-67160dbc0343 Filesystem magic number: 0xEF53 Filesystem revision #: 1 (dynamic) Filesystem features: has_journal filetype sparse_super Default mount options: (none) Filesystem state: not clean with errors Errors behavior: Continue Filesystem OS type: Linux Inode count: 9502720 Block count: 18987570 Reserved block count: 949378 Free blocks: 11555345 Free inodes: 11858398 First block: 0 Block size: 4096 Fragment size: 4096 Blocks per group: 32768 Fragments per group: 32768 Inodes per group: 16384 Inode blocks per group: 512 Last mount time: Wed Mar 24 09:31:03 2010 Last write time: Mon Apr 12 11:46:32 2010 Mount count: 10 Maximum mount count: 30 Last checked: Thu Jan 1 01:00:00 1970 Check interval: 0 (<none>) Reserved blocks uid: 0 (user root) Reserved blocks gid: 0 (group root) First inode: 11 Inode size: 128 Journal inode: 8 Journal backup: inode blocks dumpe2fs: A block group is missing an inode table while reading journal inode e2fsck 1.41.3 (12-Oct-2008) fsck.ext3: Group descriptors look bad... trying backup blocks... fsck.ext3: A block group is missing an inode table while checking ext3 journal for /dev/sda3 I tried also backup superblocks, same error result. There's any other tools I have to test before considering these disk definitely unrecoverable? Many thanks, ip

    Read the article

  • SQLSTATE[HY000]: General error: 2006 MySQL server has gone away

    - by Barkat Ullah
    Server details: RAM: 16GB HDD: 1000GB OS: Linux 2.6.32-220.7.1.el6.x86_64 Processor: 6 Core Please see the link below for my # top preview: I can often see the error mentioned in title in my plesk panel and my /etc/my.cnf configuration are as below: bind-address=127.0.0.1 local-infile=0 datadir=/var/lib/mysql socket=/var/lib/mysql/mysql.sock user=mysql max_connections=20000 max_user_connections=20000 key_buffer_size=512M join_buffer_size=4M read_buffer_size=4M read_rnd_buffer_size=512M sort_buffer_size=8M wait_timeout=300 interactive_timeout=300 connect_timeout=300 tmp_table_size=8M thread_concurrency=12 concurrent_insert=2 query_cache_limit=64M query_cache_size=128M query_cache_type=2 transaction_alloc_block_size=8192 max_allowed_packet=512M [mysqldump] quick max_allowed_packet=512M [myisamchk] key_buffer_size=128M sort_buffer_size=128M read_buffer_size=32M write_buffer_size=32M [mysqlhotcopy] interactive-timeout [mysqld_safe] log-error=/var/log/mysqld.log pid-file=/var/run/mysqld/mysqld.pid open_files_limit=8192 As my server httpd conf is set to /etc/httpd/conf.d/swtune.conf and the configuration is as below: at prefork.c: <IfModule prefork.c> StartServers 8 MinSpareServers 10 MaxSpareServers 20 ServerLimit 1536 MaxClients 1536 MaxRequestsPerChild 4000 </IfModule> If I run grep -i maxclient /var/log/httpd/error_log then I can see everyday this error: [root@u16170254 ~]# grep -i maxclient /var/log/httpd/error_log [Sun Apr 15 07:26:03 2012] [error] server reached MaxClients setting, consider raising the MaxClients setting [Mon Apr 16 06:09:22 2012] [error] server reached MaxClients setting, consider raising the MaxClients setting I tried to explain everything that I changed to keep my server okay, but maximum time my server is down. Please help me which parameter can I change to keep my server okay and my sites can load fast. It is taking too much time to load my sites.

    Read the article

  • Is this way of using Excel 2007 Pivot table for BI scalable ?

    - by Sim
    Hi all, Background: We need to consolidate sales data across the country to do analysis Our Internet connection/IT expertise/IT investment is not quite strong, therefore full BI solution is out of question I tried several SaaS BI solution (GoodData, ZohoReports) and while they're good, they seem not to fully support what we need We're looking at 'bout 2 millions record for every 2 months My current approach Our (10) sites currently gathers data from all their branches and consolidate them into 1 Excel file with Pivot table and embed source data In HQ, I will request 10 sites to send back those Excel files periodically We will import those Excel to our MSSQL server There will be a master Excel file, that will also have the same pivot table (as those came from site Excel file), and datasource is the MSSQL server More details For testing, I currently use MSSQL 2008 Express on my laptop So far, I imported our transactions for the past 2 months and there are 2 millions+ row in 1 table in MSSQL (we just use 1 table, corresponding to our common pivot table structure). DB size is ~ 600 MB In the master Excel file, if not including the source data, it's just < 10MB. Including the source data will increase the size to 60 MB (so I supposed Office 2007 automatically zip the data ?) I try using the Pivot (drag-and-drop fields) and the performance so far is OK (my laptop specs: C2D T7200, 3GB RAM, Windows XP) So my question is : If we're looking at full year transaction (roughly 15 millions rows in MSSQL 2008 Express, 3.6 GB in size), is there any issue with that 15 million rows in 1 table in SQL Express ? Is there any performance issue with the pivot table at that time ? Can it still embed the source data ? (I google-ed but didn't find the maximum size of source data Excel 2007 can embed) Any other suggestions on how we can better do this ? Given that we can't afford the full BI solution, any light-weight/budget/SaaS BI that you can recommend ? Thanks

    Read the article

  • Vista Screen resolution Changes when Switching Users

    - by Benjol
    I regularly have a problem when switching between users in Vista - the screen resolution drops down to 800x600. If I try to set the resolution back to the maximum, it says nothing, but just keeps it at 800x600. I can set it back to an intermediate value. Otherwise I have to either restart the PC, or sometimes if I log off one of the users, I can then set the resolution back to max. Might it also have something to do with using sleep mode instead of performing regular shutdowns? I thought it might be related to the desktop background image taking up too much space, but even with plain colours, the problem still occurs. There is an enormous thread on this here, but not really any answers. From what I can gather from that thread, it isn't related to any particular applications, nor limited to a particular make of graphics card or monitor, so I don't think that including hardware details is useful. This is a very annoying problem, as it screws up my desktop and screen layout every single time. Has anyone here experienced this problem or found a solution? I've noticed that Windows Update has tried to install nVidia updates and apparently they've failed on several occasions. Not sure if that is of any relevance or not. UPDATE The last post on the thread: FWIW - I had this problem for about 2 years and wrote a number of posts in this thread in the past. It survived OS reinstallation, change of practically all of my hardware piece by piece (mobo, cpu, monitor, graphics card, memory, power supply...) I used to be affected by this annoying problem at least once every 24-48 hours. About 1.5 months ago I wiped out my 32 bit vista ultimate installation and installed Windows7 ultimate 64 bit from scratch and never saw this problem again. GOOD RIDDANCE. Vista was a pathetic piece of __ that felt like a flashback to the old [horrible] NT4/Windows95 days. I was seriously considering switching over to Apple/Mac OSX if this problem persisted.

    Read the article

  • Keepalived for more than 20 virtual addresses

    - by cvaldemar
    I have set up keepalived on two Debian machines for high availability, but I've run into the maximum number of virtual IP's I can assign to my vrrp_instance. How would I go about configuring and failing over 20+ virtual IP's? This is the, very simple, setup: LB01: 10.200.85.1 LB02: 10.200.85.2 Virtual IPs: 10.200.85.100 - 10.200.85.200 Each machine is also running Apache (later Nginx) binding on the virtual IPs for SSL client certificate termination and proxying to backend webservers. The reason I need so many VIP's is the inability to use VirtualHost on HTTPS. This is my keepalived.conf: vrrp_script chk_apache2 { script "killall -0 apache2" interval 2 weight 2 } vrrp_instance VI_1 { interface eth0 state MASTER virtual_router_id 51 priority 101 virtual_ipaddress { 10.200.85.100 . . all the way to . 10.200.85.200 } An identical configuration is on the BACKUP machine, and it's working fine, but only up to the 20th IP. I have found a HOWTO discussing this problem. Basically, they suggest having just one VIP and routing all traffic "via" this one IP, and "all will be well". Is this a good approach? I'm running pfSense firewalls in front of the machines. Quote from the above link: ip route add $VNET/N via $VIP or route add $VNET netmask w.x.y.z gw $VIP Thanks in advance. EDIT: @David Schwartz said it would make sense to add a route, so I tried adding a static route to the pfSense firewall, but that didn't work as I expected it would. pfSense route: Interface: LAN Destination network: 10.200.85.200/32 (virtual IP) Gateway: 10.200.85.100 (floating virtual IP) Description: Route to VIP .100 I also made sure I had packet forwarding enabled on my hosts: $ cat /etc/sysctl.conf net.ipv4.ip_forward=1 net.ipv4.ip_nonlocal_bind=1 Am I doing this wrong? I also removed all VIPs from the keepalived.conf so it only fails over 10.200.85.100.

    Read the article

  • What is the peak theoretical WiFi G user density? [closed]

    - by Bigbio2002
    I've seen a few WiFi capacity planning questions, and this one is related, but hopefully different enough not to be closed. Also, this is related specifically to 802.11g, but a similar question could be made for N. In order to squeeze more WiFi users into a space, the transmit power on the APs need to be reduced and the APs squeezed closer together. My question is, how far can you practically take this before the network becomes unusable? There will come a point where the transmit power is so weak that nobody will actually be able to pick up a connection, or be constantly roaming to/from APs spaced a few feet apart as they walk around. There are also only 3 available channels to use as well, which is a factor to consider. After determining the peak AP density, then multiply by users-per-AP, which should be easier to find out. After factoring all of this in and running some back-of-the-envelope calculations, I'd like to be able to get a figure of "XX users per 10ft^2" or something. This can be considered the physical limit of WiFi, and will keep people from asking about getting 3,000 people in a ballroom conference on WiFi. Can anyone with WiFi experience chime in, or better yet, provide some calculations for a more accurate figure? Assumptions: Let's assume an ideal environment with no reflection (think of a big, square, open room, with the APs spaced out on a plane), APs are placed on the ceiling so humans won't absorb the waves, and the only interference are from the APs themselves and the devices. As for what devices specifically, that's irrelevant for the first point of the question (AP density, so only channel and transmit power should matter). User experience: Wikipedia states that Wireless G has about 22Mbps maximum effective throughput, or about 2.75MB/s. For the purpose of this question, anything below 100KB/s per user can be deemed to be a poor user experience. As for roaming, I'll assume the user is standing in the same place, so hopefully that will be a non-issue.

    Read the article

  • How to handle sh: fetch: command not found

    - by Tyler Johnson
    Okay, I'm a noobie. I know how to build and compose a website, but I have no idea what I'm doing when it comes to servers and server commands, etc. I've recently had a problem with all of my sites on our servers going down all at once and then I have to go in and reboot the server for them to come up again. At first this was annoying, but now it is becoming agonizing as it now takes 3-4 reboots for the websites to come back up. I contacted support for my hosting, but they are not being very helpful. They just keep telling me what the issue might be and basically telling me that I'm going to have to look into it and figure it out, which really isn't possible since I know nothing. Anyway, here are the things they said were possible reasons: They said I have "strange logs" in my Apache webserver log, error: sh: fetch: command not found. My php.ini memory limit is: 256M which is very high. It should be 32M or 64M. Server is reaching Max Clients, meaning we have more than 150 visitors at a time. (They supposedly "fixed" this, but the sites/server are still going down) I have some Wordpress sites with plugins getting errors like: PHP Warning: pack(): Type H: illegal hex digit G in... PHP Fatal error: Cannot use object of type stdClass as array in... PHP Fatal error: Maximum execution time of 30 seconds exceeded in... PHP Fatal error: Call to undefined function file_exists() in... PHP Parse error: syntax error, unexpected '<' I know that's a lot, but I really am at wits end and have no idea what to do now. If anyone could maybe give me some advice or point me in the right direction I would greatly appreciate it! Thanks! Oh, and here are the specs for my server: RAM: 2048MB CPU Shares: 40 Primary Disk: 50GB Data Transfer: 75GB Port Speed: 5Mbps

    Read the article

  • Too many concurrent connections Exchange 2010. What else is there to check?

    - by hydroparadise
    I thought that I had this under control before. But for some reason during our last email marketing promo, I start receiving from our mass email client (built in house).. The message could not be sent to the SMTP server. The transport error code is 0x800ccc67. The server repsonse was 421 4.3.2 The maximum number of concurrent connections has exceeded a limit, closing transmission channel again. There's several places I've checked to make sure that wouldn't be an issue. First I checked that receive connector was set to receive an adequate number of connections on our relay connector (1000 connections). Then, I would later find out about Throttling Policies. I created one and set all the properties I knew to set in terms of the policy following properties to 1000; EWSMaxConcurrency, OWAMaxConcurrency, CPAMaxConcurrency, and CPAMaxConcurrency. Still, the email client starts receiving the error shortly after 100 has been sent and takes about 15-30 seconds. The process is then repeatable, but still the error gets received at the same spot everytime. Is there a rate setting that I am missing? Was there a windows update that I missed looking at? Should the software have it's own throttling feature?

    Read the article

  • Small TCP Window on WAN between 2 Locations

    - by Brent
    Site A: Denver datacenter. 60MBPS. Site B: Chicago. 100MBPS. ICMP pings: Packets: Sent = 176, Received = 176, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 74ms, Maximum = 94ms, Average = 75ms File transfer between sites that never goes past ~7MBPS: Windows Update download at 60MBPS+: Site to site: IPSec VPN using two Cisco 5520's. CPU at 3-4% and lots of memory to spare. The latency between to two sites is very acceptable so I can't see an issue why it is performing so slow when transferring between the two sites. I have found that any type of transfer (FTP, HTTP, Windows file shares) will never go above ~7MBPS. When the WAN was first setup, I was able to get transfers at 50-60MBPS, which is what is expected due to the WAN connection at the Site A at 60MBPS. Then a few days later, I was not able to get anything going faster than ~7MBPS. Is there a upstream router between Denver and Chicago causing this? I want to take the blame away from our setup as downloads from Windows Update go blazing fast and for the first few days after the site to site VPN came up, I was transferring VM images at 50-60MBPS. Our stack: HP P2000 MSA - HP C7000 Chassis - HP Flex-10 - Cisco Gigabit switch - Cisco ASA - WAN

    Read the article

  • WRT54GL Tomato Router in Client wireless mode to an iPhone Personal Hotspot

    - by Gordo
    I am trying to connect a router with Tomato firmware to an iPhone 4. The goal is to connect to the Personal Hotspot in Client Wireless mode. This should allow wired and wireless users to connect to the router rather then the iPhone. In theory this should be possible but I am having difficulty. Router Linksys WRT54GL Tomato 1.28.1816 firmware iPhone iPhone 4 iOS 5.1 (9B176) Carrier Rogers Wireless Personal Hotspot works with other devices, wifi/bluetooth/usb iPhone Personal Hotspot settings Mode: B/G Security: WPA or WPA2 Personal Encryption: AES Router IP: 172.20.10.1 Subnet: 172.20.10.0 Min IP: 172.20.10.2 Max IP: 172.20.10.14 maximum number of wireless tethered hosts is 5 I have followed the directions here: http://www.wi-fiplanet.com/tutorials/article.php/3810281 Ensured that the router subnet does not 'collide' with the iPhone subnet. Here is the configuration of the Tomato 'Basic - Network - Wireless' section: http://i.stack.imgur.com/pbmTB.png I have tried several variations of this configuration, but nothing seems to work. NOTE: I have successfully connected to my own wifi network in Wireless Client mode, so I am confident that there are no bad cables or other hardware issues. I would prefer to use Tomato, but DD-WRT maybe my only other option. Thanks!

    Read the article

  • New to building computers worried about temps

    - by dave
    I'm new to building my own computers and I was wondering about maximum temperatures. I understand that the room temp can affect the computers temp but how relevent is it? I understand that if my room temp is 20°C none of my computer parts could be lower than that. But if my room is 27°C instead of 20°C would this cause my computers parts to heat up more/faster? My new computer I built myself for gaming is i7 2600k 16gb ram ddr3 1600 hd6970 2 gb 240gb ssd ( bought a nas with 3 2tb drives in raid 5 for my home network ) 850w modular psu I also have my old hp computer i3 2120 8gb ram hd6770 1tb hdd I also have 3 laptops in my household, but I am not worried about their temps, they heat up my legs but they are never under stress. Due to size and money reasons I used an old case and it only has one of the sides left on it. Is this bad for the computer and will the extra dust cause problems? Or should I leave it this way or take the missus wrath and buy a case? If so is there any certain case I should get? I don't care about looks I just want card reader and usb slots and for it to run as cool or cooler than now, my case has 1 fan. Also what are the max temps for my new and old computer parts? Is 40°C under load ok for my CPU, what about 70°C for my GPU is that ok too, or should I worry? What are normal and safe temps for my components? I have looked around but there seem to be lots of different answers. I know that 100°C is bad but I want my parts to last as long as possible and this site always seems to give good replies without arguing or flaming.

    Read the article

  • Screen Flicker on a black MacBook

    - by sixtyfootersdude
    I have a MacBook Black. For about the last six months I have had a strange screen flicker when I: start my machine and plug in the power cord of my machine This morning when I woke up my computer the screen backlight did not turn on at all. When I held the computer in direct sunlight I could see the screen and I could tell that everything was working normally (other than the backlight). Pressing the screen brightness controls (F2) brought up the brightness panel. The brightness panel informed me that the screen was at maximum brightness. I did a bit of Searching and this is what I found: This post describes how to buy and replace a macbook screen. Do you think that this would solve my problem? Additional info: I am running 10.6.4 I recently upgraded from 10.4. I experienced similar issues in 10.4. I am pretty sure that this is a hardware issue. The problem does not occur when the screen is at a specific angle. It usually only happens at startup/wakeup or when the power is plugged/unplugged.

    Read the article

  • heavy load on mysql

    - by payal
    i have dedicated server with very good configuation like 16 gb ram etc but i am facing heavy load from mysql i am running a music wesbite however only one database is running and 5-10 pages are only running.when i click on whm show processlist it shows only 2-3 processes However whm load is always less than one but when i click on whm load it shows 20% of cpu usage by mysql and after some time it starts saying can not connect to mysql . mysql server has gone away 1691 (Trace) (Kill) mysql 0 19.2 2.7 /usr/sbin/mysqld --basedir=/ --datadir=/var/lib/mysql --user=mysql --log- error=/var/lib/mysql/server.xyz.com.err --pid-file=/var/lib/mysql/server.xyz.com.pid i have tested static pages they are coming blezing fast but all dynamic pages which are using mysql is coming damn slow it takes years to open.. my.conf file is [mysqld] key_buffer = 1536M max_allowed_packet = 1M max_connections = 250 max_user_connections = 15 wait_timeout=40 connect_timeout=10 table_cache = 512 sort_buffer_size = 2M read_buffer_size = 2M read_rnd_buffer_size = 8M myisam_sort_buffer_size = 64M thread_cache_size = 8 query_cache_size = 32M server-id = 14 old-passwords = 1 [mysqldump] quick max_allowed_packet = 16M [mysql] no-auto-rehash [myisamchk] key_buffer = 256M sort_buffer_size = 256M read_buffer = 2M write_buffer = 2M [mysqlhotcopy] interactive-timeout ihave checked log error file it says nothing.i have increased maximum connnection also to 1000 but still same problem is there .if i disconnect that one databasejust by changing the name of database i can see withing half hour the load of server and mysql goes down to negliglble .i have tested everything and if there are some query which can cause heavy load to server can you please list which type of query can cause heavy load on server then also for 5-10 pages it will never cause that much heavy load. i have seen server with 500 websites but was working just fine.

    Read the article

  • heavy load on mysql

    - by payal
    i have dedicated server with very good configuation like 16 gb ram etc but i am facing heavy load from mysql however only one database is running and 5-10 pages are only running. However whm load is always less than one but when i click on whm load it shows 20% of cpu usage by mysql and after some time it starts saying can not connect to mysql . mysql server has gone away 1691 (Trace) (Kill) mysql 0 19.2 2.7 /usr/sbin/mysqld --basedir=/ --datadir=/var/lib/mysql --user=mysql --log- error=/var/lib/mysql/server.xyz.com.err --pid-file=/var/lib/mysql/server.xyz.com.pid i have tested static pages they are coming blezing fast but all dynamic pages which are using mysql is coming damn slow it takes years to open.. ihave checked log error file it says nothing.i have increased maximum connnection also to 1000 but still same problem is there .if i disconnect that one databasejust by changing the name of database i can see withing half hour the load of server and mysql goes down to negliglble .i have tested everything and if there are some query which can cause heavy load to server can you please list which type of query can cause heavy load on server then also for 5-10 pages it will never cause that much heavy load. i have seen server with 500 websites but was working just fine.

    Read the article

  • Laptop shuts down randomly without warning

    - by Robert P.
    My Asus Zenbook UX32V turns off randomly when I'm working on it. This happens both when the computer is recently turned on (5 minutes), and after being on for several days. I'm not running any heavy software The laptop is not heating The fan is not working on the maximum capacity (it's not heating) It happens when the laptop is lying still on the table It is no warning, it simply goes black It happens both when charging and on battery My guess is that it suddenly lose power somehow. What puzzles me is that I can flip the laptop upside down, sideways, shake it, etc. without it shutting off. This makes me think it's not something that's loose causing occasional short-circuits. I realize that the laptop probably doesn't like flipping and shaking, but it was the best way I could troubleshoot. I rarely turn the computer off, only have it in hibernate or sleep mode (most often hibernate). I've never experienced that the laptop is off when I wake it up from sleep mode. I've had the problem for a few months and it happens 2-8 times a week. Specs: Asus Zenbook UX32V Windows 8.1 (it happened in Windows 8.0 too) Intel i5-3317U CPU @ 1.70GHz The laptop is approx 1.5 years, but it has a small dent on one of the sides that probably voids the warranty. The dent has been there since week one and I don't think it's related to the problems I'm having now. Does anyone have a clue what might cause this, and how it might be fixed? I've read all other questions (some of which are listed below) that seem related to my issue, but none report the same behavior as I'm experiencing. Most report heavy games, heating etc. Asus N53J Laptop randomly shuts down Laptop is randomly shutting off Computer shuts down without warning My laptop acer aspire 5720 suddenly turn off randomly Computer randomly shutting down Windows 8.1 randomly shuts self down ASUS K55VM Laptop unexpectedly shuts down

    Read the article

  • Any program to help me check whether an ethernet channel can support full-length VLAN packet?

    - by Jimm Chen
    Sometimes, I have to face such a situation that I need to quickly and explicitly know whether a full length VLAN packet can traverse between two RJ45 ports. Yes, I mean 802.1Q ethernet frame with Etype=81 00 (diagram below). What I can do now is: Get two Windows PCs, for each PC, intall Intel Gigabit NIC and Intel specific driver to create a virtual NIC, with VLAN ID=3 assigned. Then connect the two PCs to each of the two RJ45 port. Finally execute ping to generate a full-length ethernet packet. ping -f -l 1472 <dest-IP> This way, I can be sure that the sent packet has the maximum "IP data payload" of 1500 bytes(8 bytes of ICMP header and 1472 bytes of ICMP data). If the ping gets reply, I know that the ethernet channel support full-length VLAN packet. From my experiment, some home switch or broad band routers(e.g. Linksys WRT54G) does not support full-length VLAN packet switching, so only ping -f -l 1468 succeeds. You see, I have to use an expensive Intel NIC to carry on that test, quite inconvenient. You know, for most laptop today, they do not equip an Intel NIC, and, even it is an Intel NIC, Intel VLAN driver, Intel has limitations on the models on which VLAN driver can be installed. So, my question is: Is there a small program that can let me send a full-length VLAN packet without installing a dedicated VLAN driver? Or better, the program has a stock feature that does the very job for my situation. Windows programs preferred, Linux solution welcome. Simpler the program, the better. Thank you.

    Read the article

  • GUI interfaces to ATI card behave weirdly out of the box and after updates.

    - by jdk
    My Lenovo W500 came with an ATI Mobility FireGL V5700 and both the Catalyst control center software and Vista display manager display four monitors. What's really annoying is the behaviour. My two active displays (laptop display + my external monitor) are always #s 3 and 4 respectively which doesn't make sense. This is out of the box. Additionally dragging & dropping is jumpy and displays #1 and 2 (always inactive because they don't exist to the software) are often preventing me from dragging #3 and 4 to the rightmost side. They also auto-snap to weird positions and certain sensible positions like position one directly over top of the other are not possible. The exact same annoyances are present when using the Windows Display manager too. In other words the interface is crap and I'm looking for a fix that's not wishing I had gone with nVidia instead. I've updated drivers, and Catalyst control centre. Have latest Windows and AMD/ATI updates. Any thoughts? Graphics Software Driver Packaging Version 8.563.2.1-090401a-079160C-Lenovo Provider ATI Technologies Inc. 2D Driver Version 7.01.01.849 2D Driver File Path /REGISTRY/MACHINE/SYSTEM/ControlSet001/Control/Class/{4D36E968-E325-11CE-BFC1-08002BE10318}/0001 Direct3D Version 7.14.10.0630 OpenGL Version 6.14.10.8306 Catalyst® Control Center Version 2009.0401.1328.22301 Graphics Hardware Primary Adapter Graphics Card Manufacturer Powered by ATI Graphics Chipset ATI Mobility FireGL V5700 Device ID 9591 Vendor 1002 Subsystem ID 2126 Subsystem Vendor ID 17AA Graphics Bus Capability PCI Express 2.0 Maximum Bus Setting PCI Express 2.0 x16 BIOS Version 010.088.000.021 BIOS Part Number BK-ATI VER010.088.000.021.034663 BIOS Date 2009/09/30 Memory Size 512 MB Memory Type DDR3 Core Clock in MHz 600 MHz Memory Clock in MHz 700 MHz

    Read the article

  • vmware esxi 5, cant create snapshots and consolidate fails, how to delete old or consolidate redo logs?

    - by Scott Szretter
    I have a VM that seems to be working ok, but when VMWare DR (or I) tries to create a snap shot, it fails, and when I view the summary page of the VM it has a warning at the top showing that the disks need to be consolidated. So I go to snapshot manager for the VM and choose consolidate (in snapshot manager, there are no snapshots actually listed by the way). If fails with this error: This virtual machine has 255 or more redo logs in a single branch of its snapshot tree. The maximum supported limit has been reached, creating new snapshots will not be allowed. To create new snapshots, please delete old snapshots or consolidate the redo logs. If I browse the data store (which has plenty of free space, 2 TB and this vm is under 40gb), in the vm folder, I do in fact see a bunch of files, numbered all the way to 0255: myvm-000255-ctk.vmdk myvm-000255-delta.vmdk myvm-000255.vmdk How can I clean all this up? Is there an SSH command line command or can I delete some of the files safely? Thanks!

    Read the article

  • ubuntu dmidecode is not functioning properly

    - by Alaa Alomari
    dmidecode is giving irrelevant and conflicted results. it shows that i have two slots while the correct is 8 (the board is Tyan S5350.) uname -a Linux synd01 3.0.0-16-server #29-Ubuntu SMP Tue Feb 14 13:08:12 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux root@synd01:/home/badmin# dmidecode -t 16 dmidecode 2.9 SMBIOS 2.33 present. Handle 0x0011, DMI type 16, 15 bytes Physical Memory Array Location: System Board Or Motherboard Use: System Memory Error Correction Type: None Maximum Capacity: 4 GB Error Information Handle: Not Provided Number Of Devices: 2 while root@synd01:/home/badmin# dmidecode -t 17 | grep Size Size: No Module Installed Size: No Module Installed Size: 1024 MB Size: 1024 MB Size: No Module Installed Size: No Module Installed Size: 1024 MB Size: 1024 MB also lshw shows: *-memory description: System Memory physical id: 11 slot: System board or motherboard size: 4GiB *-bank:0 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 0 slot: J3B1 clock: 166MHz (6.0ns) *-bank:1 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 1 slot: J3B3 clock: 166MHz (6.0ns) *-bank:2 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 2 slot: J2B2 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) *-bank:3 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 3 slot: J2B4 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) *-bank:4 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 4 slot: J3B2 clock: 166MHz (6.0ns) *-bank:5 description: DIMM DDR Synchronous 166 MHz (6.0 ns) [empty] physical id: 5 slot: J2B1 clock: 166MHz (6.0ns) *-bank:6 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 6 slot: J2B3 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) *-bank:7 description: DIMM DDR Synchronous 166 MHz (6.0 ns) physical id: 7 slot: J1B1 size: 1GiB width: 64 bits clock: 166MHz (6.0ns) what might cause this conflict and how can i fix it? Thanks

    Read the article

  • Is there any way for ME to improve routing to an overseas server? [migrated]

    - by Simon Hartcher
    I am trying to make a connection to a gaming server in Asia from Australia, but my ISP routes my connection through the US. Tracing route to worldoftanks-sea.com [116.51.25.54]over a maximum of 30 hops: 1 <1 ms <1 ms <1 ms 192.168.1.1 2 34 ms 42 ms 45 ms 10.20.21.123 3 40 ms 40 ms 43 ms 202.7.173.145 4 51 ms 42 ms 36 ms syd-sot-ken-crt1-ge-6-0-0.tpgi.com.au [202.7.171.121] 5 175 ms 200 ms 195 ms ge5-0-5d0.cir1.seattle7-wa.us.xo.net [216.156.100.37] 6 212 ms 228 ms 229 ms vb2002.rar3.sanjose-ca.us.xo.net [207.88.13.150] 7 205 ms 204 ms 206 ms 207.88.14.226.ptr.us.xo.net [207.88.14.226] 8 207 ms 215 ms 220 ms xe-0.equinix.snjsca04.us.bb.gin.ntt.net [206.223.116.12] 9 198 ms 201 ms 199 ms ae-7.r20.snjsca04.us.bb.gin.ntt.net [129.250.5.52] 10 396 ms 391 ms 395 ms as-6.r20.sngpsi02.sg.bb.gin.ntt.net [129.250.3.89] 11 383 ms 384 ms 383 ms ae-3.r02.sngpsi02.sg.bb.gin.ntt.net [129.250.4.178] 12 364 ms 381 ms 359 ms wotsg1-slave-54.worldoftanks.sg [116.51.25.54] Trace complete. Since I think it will be unlikely that my ISP will do anything, are there any ways to improve my routing to the server without them having to intervene? NB. The game runs predominately over UDP, so I believe most low ping services are out of the question, as they rely on TCP traffic.

    Read the article

  • Flash drive suddenly died. Why? Can I recover it?

    - by mg
    Hi, I have a flash drive that I used not too much but, after few month of inactivity, it died. I know that flash drives have a limited write cycles but I am sure that this is not the problem. I tried to create a new partition table and format the drive nothing worked. This is the output of mkfs.ext2. marco@pinguina:~$ sudo LANG=en.UTF-8 mkfs.ext2 -v -c /dev/sdc1 [sudo] password for marco: mke2fs 1.41.11 (14-Mar-2010) fs_types for mke2fs.conf resolution: 'ext2', 'default' Calling BLKDISCARD from 0 to 4001431552 failed. Filesystem label= OS type: Linux Block size=4096 (log=2) Fragment size=4096 (log=2) Stride=0 blocks, Stripe width=0 blocks 244320 inodes, 976912 blocks 48845 blocks (5.00%) reserved for the super user First data block=0 Maximum filesystem blocks=1002438656 30 block groups 32768 blocks per group, 32768 fragments per group 8144 inodes per group Superblock backups stored on blocks: 32768, 98304, 163840, 229376, 294912, 819200, 884736 Running command: badblocks -b 4096 -X -s /dev/sdc1 976911 badblocks: Input/output error during ext2fs_sync_device Checking for bad blocks (read-only test): done Block 0 in primary superblock/group descriptor area bad. Blocks 0 through 2 must be good in order to build a filesystem. Aborting.... Is there something I can do to recover it?

    Read the article

  • After upgrading to 2008 R2 Enterprise and installing more RAM, Windows can only see 4.00 GB

    - by Tom Crane
    (I have also posted this on technet but I'm running out of ideas) I've upgraded from Windows Server 2008 R2 Standard to Enterprise in order to make use of more RAM. The server previously had 32GB of RAM. The upgrade from Standard to Enterprise, using DISM, seemed to go OK, so I powered down and installed the RAM. This a Dell Poweredge T710, I was taking it from 32GB to 72GB. The BIOS recognised the RAM, although I needed to change from "Advanced ECC" to "Optimizer" mode for it to use all of it. After rebooting, windows can see the RAM but in the system panel will display: Installed memory (RAM): 72.0 GB (4.00 GB usable) In the resource monitor, the remainder of the RAM is showing as reserved for hardware. I've tried various RAM configurations, including reverting it to the same chips and same configuration as before the upgrade, but always just 4.00 GB is showing up as usable. Following some threads on these forums I've gone into msconfig and set the maximum memory "by hand" but that doesn't fix the problem. BIOS doesn't seem to have anything that looks like memory remapping which is another suggestion that has come up. How do I make this RAM available to Windows? It was available before the upgrade, because I could use the full 32GB RAM the server had to start with. A screenshot (this is after reverting to the original RAM configuration) http://screencast.com/t/5FuzevdNb I don't know if it's related, but my remote desktop configuration has also disappeared: screencast.com/t/mYedomeQWS (the bottom half of this dialog should allow me to configure Remote Desktop, it was working before the upgrade but now it isn't).

    Read the article

< Previous Page | 87 88 89 90 91 92 93 94 95 96 97 98  | Next Page >