Search Results

Search found 22709 results on 909 pages for '64 bit'.

Page 93/909 | < Previous Page | 89 90 91 92 93 94 95 96 97 98 99 100  | Next Page >

  • CentOS 6.3 Virtual under OpenVZ cannot ping, host lookups, outbound connections while postfix running

    - by Paul Cravey
    My best theory is that some kernel limit is being hit preventing outbound connections. We have tried basically everything from tcpdumps to provisioning an entirely new virtual server (we do not have this problem on any other virtuals), however the problem somehow carried over, even with new postfix build (working). Emails work, and outbound connections work, so long as postfix does not have too much going on. /proc/user_beancounters shows no limits being hit (show below). Nevertheless, pings fail even to IP addresses. TCP stack appears healthy. Load is low. No iowait. Flushed iptables already. Has anyone experienced anything like this? uid resource held maxheld barrier limit failcnt 3: kmemsize 166216365 170262528 9223372036854775807 9223372036854775807 0 lockedpages 0 0 9223372036854775807 9223372036854775807 0 privvmpages 285727 351885 9223372036854775807 9223372036854775807 0 shmpages 16933 17605 9223372036854775807 9223372036854775807 0 dummy 0 0 0 0 0 numproc 150 303 9223372036854775807 9223372036854775807 0 physpages 314156 326191 0 1280000 0 vmguarpages 0 0 9223372036854775807 9223372036854775807 0 oomguarpages 165355 165355 9223372036854775807 9223372036854775807 0 numtcpsock 89 172 9223372036854775807 9223372036854775807 0 numflock 22 76 9223372036854775807 9223372036854775807 0 numpty 1 2 9223372036854775807 9223372036854775807 0 numsiginfo 0 75 9223372036854775807 9223372036854775807 0 tcpsndbuf 2733472 4371752 9223372036854775807 9223372036854775807 0 tcprcvbuf 1798336 5427296 9223372036854775807 9223372036854775807 0 othersockbuf 491120 1000760 9223372036854775807 9223372036854775807 0 dgramrcvbuf 0 238728 9223372036854775807 9223372036854775807 0 numothersock 361 505 9223372036854775807 9223372036854775807 0 dcachesize 135941831 136114679 9223372036854775807 9223372036854775807 0 numfile 2905 4990 9223372036854775807 9223372036854775807 0 dummy 0 0 0 0 0 dummy 0 0 0 0 0 dummy 0 0 0 0 0 numiptent 8 9 9223372036854775807 9223372036854775807 0 [root@bni /]# ping 4.2.2.1 PING 4.2.2.1 (4.2.2.1) 56(84) bytes of data. --- 4.2.2.1 ping statistics --- 9 packets transmitted, 0 received, 100% packet loss, time 8493ms [root@bni /]# service postfix stop [root@bni /]# ping 4.2.2.1 PING 4.2.2.1 (4.2.2.1) 56(84) bytes of data. 64 bytes from 4.2.2.1: icmp_seq=1 ttl=53 time=8.63 ms 64 bytes from 4.2.2.1: icmp_seq=2 ttl=53 time=8.62 ms 64 bytes from 4.2.2.1: icmp_seq=3 ttl=53 time=8.63 ms 64 bytes from 4.2.2.1: icmp_seq=4 ttl=53 time=8.66 ms Outbound connections of all sorts fail when postfix is running.

    Read the article

  • ipv6 reverse DNS delegation

    - by user1709492
    I currently have 2001:1973:2303::/48 assigned to me and i'll be assigning /64's to customer's I'd like to have 1 zonefile for the /48 where i can essentially point / redirect query to different nameservers. Example ( Desired effect ) 2001:1973:2303:1234::/64 -> ns1.example.com, ns2.example.com 2001:1973:2303:2345::/64 -> ns99.example2.com, ns100.example2.com 2001:1973:2303:4321::/64 -> ns1.cust1.com, ns2.cust1.com Current /48 zonefile $TTL 3h $ORIGIN 3.0.3.2.3.7.9.1.1.0.0.2.ip6.arpa. @ IN SOA ns3.example.ca. ns4.example.ca. ( 2011071030 ; serial 3h ; refresh after 3 hours 1h ; retry after 1 hour 1w ; expire after 1 week 1h ) ; negative caching TTL of 1 hour IN NS ns3.example.ca. IN NS ns4.example.ca. 1234 IN NS ns1.example.com. NS ns2.example.com. 2345 IN NS ns99.example2.com. NS ns100.example2.com. 4321 IN NS ns1.cust1.com. NS ns2.cust1.com. Where am i going wrong ? My request seems simple to me atleast. To put it in terms of firewalling i want to redirect traffic client queries 2001:1973:2303:4321::1 - ns3.example.ca sees the request and redirects the query to ns1.cust1.com - ns1.cust1.com answers the query with omg.itworks.ca ( provided ns1.cust1.com is properly configured.

    Read the article

  • Advertise a subnet route with radvd

    - by Thomas Berger
    we have set up a small IPv6 Testing network. The setup looks like this: ::/0 +----------+ | Firewall | Router to the public net +----------+ | 2001:...::/106 | +----------+ +-------| SIT GW | sit Tunnel gatway to the some test users | +----------+ | +----------+ | Test Sys | Testsystem +----------+ The idea is to advertise the default route from the firewall and the route for the SIT subnets from the sit gateway. The configurations for radvd are: # Firewall interface eth0 { AdvSendAdvert on; route ::/0 { }; }; # SIT Gatway interface eth0 { AdvSendAdvert on; route 2001:...::/106 { }; }; We have captured the adv. packages with tcpdump and the packages looks good. We see a default route from the fw, and the subnet route from the SIT gatway. But if we look on the testsystem there are two default routes over both gateways. There is no subnet route. The routing does not work of course. Here the routes we get: 2001:.....::/64 dev eth0 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 fe80::/64 dev eth0 proto kernel metric 256 mtu 1500 advmss 1440 hoplimit 4294967295 default via fe80::baac:6fff:fe8e:XXXX dev eth0 proto kernel metric 1024 expires 0sec mtu 1500 advmss 1440 hoplimit 64 default via fe80::e415:aeff:fe12:XXXX dev eth0 proto kernel metric 1024 expires 0sec mtu 1500 advmss 1440 hoplimit 64 Any Idea?

    Read the article

  • Error: could not create the Java Virtual Machine. Error: A fatal exception has occurred. Program will exit

    - by Gleeson9
    Pre-note: This is not a problem I am having with Minecraft. All answers I can find seem to be Minecraft issues. Error: could not create the Java Virtual Machine. Error: A fatal exception has occurred. Program will exit. I get this error when I try to do something Java related. I cannot launch a .jar without this error coming up and when I try to install JDK, I get this error. This has been plauging me for a while and I was not able to research an answer so I thought I would ask it myself. EDIT: Windows 7 (x64) Dell Studio Laptop, 4GB RAM, external Radeon HD 6950 Graphics Card. I have tried uninstalling all JVMs and reinstalling but it didn't work, although I cannot remember how thorough I was so I may try again. Here is a list of all the Java related things I have installed (found in the uninstall or change programs window): Java 3D 1.5.1 Java 3D 1.5.1 (x64) Java 3D 1.5.2 Java 6 Update 30 Java 6 Update 30 (64-bit) Java 7 Update 2 Java 7 Update 3 (64-bit) JavaFX 2.0.3 (64-bit) JavaFX 2.0.3 SDK (64-bit)

    Read the article

  • Proper configuration for Windows SMTP Virtual Server to only send email from localhost, and tracking down source of spam emails

    - by ilasno
    We manage a server that is hosted on Amazon EC2, which has web applications that need to be able to send outgoing email. Recently we received a notice from Amazon about possible email abuse on that server, so i've been looking into it. It's Windows Server Datacenter (2003, i guess), and uses SMTP Virtual Server (you know, the one that requires IIS 6 for admin). The settings on the Access tab are as follows: - Authentication: Anonymous - Connection: Only from 3 ip addresses (127.0.0.1 and 2 others that refer to that server) - Relay: Only from 3 ip addresses (127.0.0.1 and 2 others that refer to that server) In the SMTP logs there are many entries like the following: 2012-02-08 23:43:56 64.76.125.151 OutboundConnectionCommand SMTPSVC1 FROM: 0 0 4 0 26364 SMTP - - - - 2012-02-08 23:43:56 64.76.125.151 OutboundConnectionResponse SMTPSVC1 250+ok 0 0 6 0 26536 SMTP - - - - 2012-02-08 23:43:56 64.76.125.151 OutboundConnectionCommand SMTPSVC1 TO: 0 0 4 0 26536 SMTP - - - - 2012-02-08 23:43:56 64.76.125.151 OutboundConnectionResponse SMTPSVC1 250+ok 0 0 6 0 26707 SMTP - - - - ([email protected] is sending quite a lot of emails :-/) Can anyone confirm if the SMTP server settings seem correct? I'm also wondering if a web application on the machine could be exposing a contact form or something that would allow this sort of abuse, looking into that (and how to look into that) further.

    Read the article

  • Nginx Server Block Not Working? - Already running other vhosts just this one not working

    - by daveaspinall
    Im running a Debian 6 LEMP server with multiple virtual hosts and everything has been fine for 5 or so sites. But I've just tried adding another but for some reason it's just not working. By not working I mean in Chrome I get the "Oops! Google Chrome could not connect to subdomain.domain.net" error. I've changed the domain for security to subdomain.example.com and the IP is masked. Hosts file (I have multiple sub domains): xxx.xxx.xx.xxx *.example.com *.example Server Block: server { listen 80; server_name subdomain.example.com; access_log /srv/www/subdomain.example.com/logs/access.log; error_log /srv/www/subdomain.example.com/logs/error.log; root /srv/www/subdomain.example.com/public_html; location / { index index.html index.htm index.php; } location ~ \.php$ { include fastcgi_params; fastcgi_pass 127.0.0.1:9000; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; } } I've created the system link to the file in the /etc/nginx/sites-enabled/ directory and restarted/reloaded nginx. DNS seems fine: # ping -c 2 subdomain PING subdomain.example.com (xxx.xxx.xx.xxx) 56(84) bytes of data. 64 bytes from www.example.com (xxx.xxx.xx.xxx): icmp_req=1 ttl=64 time=0.035 ms 64 bytes from www.example.com (xxx.xxx.xx.xxx): icmp_req=2 ttl=64 time=0.048 ms Checking the file with cURL works: # curl http://subdomain.example.com HTML - OK Emptied browser cache but still no dice. Anything I'm missing? Like I mentioned, I have a few sites running fine on the server currently so php-fpm etc etc are working. Any help would be much appreciated! Cheers, Dave

    Read the article

  • Notepad and Regedit does not launch from C:\Windows or C:\Windows\System32, but will from C:\Windows\SysWOW64

    - by lordhog
    My work machine was recently updated from Windows XP 64-bit to Windows 7 64-bit. I have found a few odd things that I can not figure out why they are occurring. If I type in Notepad.exe or RegEdit.exe from the Run diaglog the applications will not launch. When executing RegEdit.exe from the Run dialog the UAC does display asking for admin privileges, but the application never launches. Also, if I go to the Start menu and click on Notepad from there, Notepad never launches either. Other programs seem to be okay, like mspaint, wordpad, etc. Now, if I launch Notepad or RegEdit from C:\Windows\SysWOW64 then these applications will run, though I think these are the 32-bit version and not the 64-bit version. I am not sure what is going on. Has anyone seen this behavior before and how to fix it? I have Windows 7 64-bit at home and I don't have this issue. I even copied Notepad.exe from home and place it in the C:\ folder and tried to launch it from there and it still doesn't work. Regards, Mark

    Read the article

  • GCC, -O2, and bitfields - is this a bug or a feature?

    - by Rooke
    Today I discovered alarming behavior when experimenting with bit fields. For the sake of discussion and simplicity, here's an example program: #include <stdio.h> struct Node { int a:16 __attribute__ ((packed)); int b:16 __attribute__ ((packed)); unsigned int c:27 __attribute__ ((packed)); unsigned int d:3 __attribute__ ((packed)); unsigned int e:2 __attribute__ ((packed)); }; int main (int argc, char *argv[]) { Node n; n.a = 12345; n.b = -23456; n.c = 0x7ffffff; n.d = 0x7; n.e = 0x3; printf("3-bit field cast to int: %d\n",(int)n.d); n.d++; printf("3-bit field cast to int: %d\n",(int)n.d); } The program is purposely causing the 3-bit bit-field to overflow. Here's the (correct) output when compiled using "g++ -O0": 3-bit field cast to int: 7 3-bit field cast to int: 0 Here's the output when compiled using "g++ -O2" (and -O3): 3-bit field cast to int: 7 3-bit field cast to int: 8 Checking the assembly of the latter example, I found this: movl $7, %esi movl $.LC1, %edi xorl %eax, %eax call printf movl $8, %esi movl $.LC1, %edi xorl %eax, %eax call printf xorl %eax, %eax addq $8, %rsp The optimizations have just inserted "8", assuming 7+1=8 when in fact the number overflows and is zero. Fortunately the code I care about doesn't overflow as far as I know, but this situation scares me - is this a known bug, a feature, or is this expected behavior? When can I expect gcc to be right about this? Edit (re: signed/unsigned) : It's being treated as unsigned because it's declared as unsigned. Declaring it as int you get the output (with O0): 3-bit field cast to int: -1 3-bit field cast to int: 0 An even funnier thing happens with -O2 in this case: 3-bit field cast to int: 7 3-bit field cast to int: 8 I admit that attribute is a fishy thing to use; in this case it's a difference in optimization settings I'm concerned about.

    Read the article

  • ORA-03113 in code. In addition, TNS-12535 and ORA-03137 in alert file

    - by user1348107
    I've got an exception that contain ORA-03113: (SiPPSS.GetPrintWorkDirectDetail) - ERR:ORA-03113: end-of-file on communication channel Process ID: 7448 Session ID: 30 Serial number: 9802 ?????:12110937 ????:T855 Oracle.DataAccess.Client.OracleException ORA-03113: end-of-file on communication channel Process ID: 7448 Session ID: 30 Serial number: 9802 ?? Oracle.DataAccess.Client.OracleException.HandleErrorHelper(Int32 errCode, OracleConnection conn, IntPtr opsErrCtx, OpoSqlValCtx* pOpoSqlValCtx, Object src, String procedure, Boolean bCheck) ?? Oracle.DataAccess.Client.OracleException.HandleError(Int32 errCode, OracleConnection conn, String procedure, IntPtr opsErrCtx, OpoSqlValCtx* pOpoSqlValCtx, Object src, Boolean bCheck) ?? Oracle.DataAccess.Client.OracleCommand.ExecuteReader(Boolean requery, Boolean fillRequest, CommandBehavior behavior) ?? Oracle.DataAccess.Client.OracleDataAdapter.Fill(DataTable[] dataTables, Int32 startRecord, Int32 maxRecords, IDbCommand command, CommandBehavior behavior) ?? System.Data.Common.DbDataAdapter.Fill(DataTable dataTable) ?? SiPPSS.VSireiMeisaiDsTableAdapters.V_SIREI_MEISAITableAdapter.FillByRunningNoAndProcNo(V_SIREI_MEISAIDataTable dataTable, String RUNNING_NO, String PROC_NO) ?? C:\SVM\trunk\SiPPSSServer\Server\Dao\View\VSireiMeisaiDs.Designer.vb:? 386 ?? SiPPSS.GetPrintWorkDirectDetail.Execute(BLogicParam param) ?? C:\SVM\trunk\SiPPSSServer\Server\BLogic\Screen\Printing\Rprt0701\GetPrintWorkDirectDetail.vb:? 105 In this case, the oracle alert log as beblow: Fatal NI connect error 12170. VERSION INFORMATION: TNS for 64-bit Windows: Version 11.2.0.1.0 - Production Oracle Bequeath NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Windows NT TCP/IP NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Time: 01-11?-2012 13:50:45 Tracing not turned on. Tns error struct: ns main err code: 12535 TNS-12535: TNS: ??????·???????? ns secondary err code: 12560 nt main err code: 505 TNS-00505: ??????????? nt secondary err code: 60 nt OS err code: 0 Client address: (ADDRESS=(PROTOCOL=tcp)(HOST=10.41.102.53)(PORT=1794)) Thu Nov 01 13:54:17 2012 Thread 1 cannot allocate new log, sequence 1880 Private strand flush not complete Current log# 1 seq# 1879 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1880 (LGWR switch) Current log# 2 seq# 1880 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 13:54:21 2012 Archived Log entry 1118 added for thread 1 sequence 1879 ID 0xe48db805 dest 1: Thu Nov 01 14:40:12 2012 Thread 1 cannot allocate new log, sequence 1881 Private strand flush not complete Current log# 2 seq# 1880 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1881 (LGWR switch) Current log# 3 seq# 1881 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 14:40:16 2012 Archived Log entry 1119 added for thread 1 sequence 1880 ID 0xe48db805 dest 1: Thu Nov 01 15:27:42 2012 Thread 1 cannot allocate new log, sequence 1882 Private strand flush not complete Current log# 3 seq# 1881 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1882 (LGWR switch) Current log# 1 seq# 1882 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 15:27:46 2012 Archived Log entry 1120 added for thread 1 sequence 1881 ID 0xe48db805 dest 1: Thu Nov 01 16:23:48 2012 Thread 1 cannot allocate new log, sequence 1883 Private strand flush not complete Current log# 1 seq# 1882 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1883 (LGWR switch) Current log# 2 seq# 1883 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 16:23:52 2012 Archived Log entry 1121 added for thread 1 sequence 1882 ID 0xe48db805 dest 1: Thu Nov 01 17:05:50 2012 Thread 1 cannot allocate new log, sequence 1884 Private strand flush not complete Current log# 2 seq# 1883 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1884 (LGWR switch) Current log# 3 seq# 1884 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 17:05:55 2012 Archived Log entry 1122 added for thread 1 sequence 1883 ID 0xe48db805 dest 1: Thu Nov 01 17:26:52 2012 Fatal NI connect error 12170. VERSION INFORMATION: TNS for 64-bit Windows: Version 11.2.0.1.0 - Production Oracle Bequeath NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Windows NT TCP/IP NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Time: 01-11?-2012 17:26:52 Tracing not turned on. Tns error struct: ns main err code: 12535 TNS-12535: TNS: ??????·???????? ns secondary err code: 12560 nt main err code: 505 TNS-00505: ??????????? nt secondary err code: 60 nt OS err code: 0 Client address: (ADDRESS=(PROTOCOL=tcp)(HOST=10.41.102.62)(PORT=1286)) Thu Nov 01 17:27:16 2012 Fatal NI connect error 12170. VERSION INFORMATION: TNS for 64-bit Windows: Version 11.2.0.1.0 - Production Oracle Bequeath NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Windows NT TCP/IP NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Time: 01-11?-2012 17:27:16 Tracing not turned on. Tns error struct: ns main err code: 12535 TNS-12535: TNS: ??????·???????? ns secondary err code: 12560 nt main err code: 505 TNS-00505: ??????????? nt secondary err code: 60 nt OS err code: 0 Client address: (ADDRESS=(PROTOCOL=tcp)(HOST=10.41.102.62)(PORT=1285)) Thu Nov 01 18:08:39 2012 Thread 1 advanced to log sequence 1885 (LGWR switch) Current log# 1 seq# 1885 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 18:08:40 2012 Archived Log entry 1123 added for thread 1 sequence 1884 ID 0xe48db805 dest 1: Thu Nov 01 19:33:21 2012 Thread 1 cannot allocate new log, sequence 1886 Private strand flush not complete Current log# 1 seq# 1885 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1886 (LGWR switch) Current log# 2 seq# 1886 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 19:33:25 2012 Archived Log entry 1124 added for thread 1 sequence 1885 ID 0xe48db805 dest 1: Thu Nov 01 20:32:25 2012 Thread 1 cannot allocate new log, sequence 1887 Private strand flush not complete Current log# 2 seq# 1886 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1887 (LGWR switch) Current log# 3 seq# 1887 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 20:32:29 2012 Archived Log entry 1125 added for thread 1 sequence 1886 ID 0xe48db805 dest 1: Thu Nov 01 21:13:07 2012 Thread 1 advanced to log sequence 1888 (LGWR switch) Current log# 1 seq# 1888 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 21:13:08 2012 Archived Log entry 1126 added for thread 1 sequence 1887 ID 0xe48db805 dest 1: Thu Nov 01 22:00:00 2012 Setting Resource Manager plan SCHEDULER[0x3006]:DEFAULT_MAINTENANCE_PLAN via scheduler window Setting Resource Manager plan DEFAULT_MAINTENANCE_PLAN via parameter Thu Nov 01 22:00:00 2012 Starting background process VKRM Thu Nov 01 22:00:00 2012 VKRM started with pid=32, OS id=4048 Thu Nov 01 22:00:59 2012 Thread 1 cannot allocate new log, sequence 1889 Private strand flush not complete Current log# 1 seq# 1888 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1889 (LGWR switch) Current log# 2 seq# 1889 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 22:01:03 2012 Archived Log entry 1127 added for thread 1 sequence 1888 ID 0xe48db805 dest 1: Thu Nov 01 22:32:36 2012 Thread 1 advanced to log sequence 1890 (LGWR switch) Current log# 3 seq# 1890 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 22:32:37 2012 Archived Log entry 1128 added for thread 1 sequence 1889 ID 0xe48db805 dest 1: Thu Nov 01 22:33:18 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_11884.trc (incident=101313): ORA-03137: TTC protocol internal error : [12333] [8] [49] [50] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101313\siporex_ora_11884_i101313.trc Thu Nov 01 22:33:21 2012 Trace dumping is performing id=[cdmp_20121101223321] Thu Nov 01 22:40:43 2012 Thread 1 cannot allocate new log, sequence 1891 Private strand flush not complete Current log# 3 seq# 1890 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1891 (LGWR switch) Current log# 1 seq# 1891 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 22:40:47 2012 Archived Log entry 1129 added for thread 1 sequence 1890 ID 0xe48db805 dest 1: Thu Nov 01 23:47:30 2012 Thread 1 cannot allocate new log, sequence 1892 Private strand flush not complete Current log# 1 seq# 1891 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1892 (LGWR switch) Current log# 2 seq# 1892 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 23:47:34 2012 Archived Log entry 1130 added for thread 1 sequence 1891 ID 0xe48db805 dest 1: Fri Nov 02 00:49:31 2012 Thread 1 cannot allocate new log, sequence 1893 Private strand flush not complete Current log# 2 seq# 1892 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1893 (LGWR switch) Current log# 3 seq# 1893 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 00:49:35 2012 Archived Log entry 1131 added for thread 1 sequence 1892 ID 0xe48db805 dest 1: Fri Nov 02 01:43:12 2012 Thread 1 cannot allocate new log, sequence 1894 Private strand flush not complete Current log# 3 seq# 1893 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1894 (LGWR switch) Current log# 1 seq# 1894 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 01:43:17 2012 Archived Log entry 1132 added for thread 1 sequence 1893 ID 0xe48db805 dest 1: Fri Nov 02 01:52:51 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_6124.trc (incident=101273): ORA-03137: TTC protocol internal error : [12333] [4] [80] [82] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101273\siporex_ora_6124_i101273.trc Fri Nov 02 01:52:54 2012 Trace dumping is performing id=[cdmp_20121102015254] Fri Nov 02 02:00:00 2012 Clearing Resource Manager plan via parameter Fri Nov 02 02:43:37 2012 Thread 1 cannot allocate new log, sequence 1895 Private strand flush not complete Current log# 1 seq# 1894 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1895 (LGWR switch) Current log# 2 seq# 1895 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 02:43:41 2012 Archived Log entry 1133 added for thread 1 sequence 1894 ID 0xe48db805 dest 1: Fri Nov 02 04:46:18 2012 Thread 1 cannot allocate new log, sequence 1896 Private strand flush not complete Current log# 2 seq# 1895 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1896 (LGWR switch) Current log# 3 seq# 1896 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 04:46:22 2012 Archived Log entry 1134 added for thread 1 sequence 1895 ID 0xe48db805 dest 1: Fri Nov 02 04:51:41 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_4048.trc (incident=101425): ORA-03137: TTC protocol internal error : [12333] [4] [67] [85] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101425\siporex_ora_4048_i101425.trc Fri Nov 02 04:51:44 2012 Trace dumping is performing id=[cdmp_20121102045144] Fri Nov 02 05:54:44 2012 Thread 1 cannot allocate new log, sequence 1897 Private strand flush not complete Current log# 3 seq# 1896 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1897 (LGWR switch) Current log# 1 seq# 1897 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 05:54:48 2012 Archived Log entry 1135 added for thread 1 sequence 1896 ID 0xe48db805 dest 1: Fri Nov 02 07:00:34 2012 Thread 1 cannot allocate new log, sequence 1898 Private strand flush not complete Current log# 1 seq# 1897 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1898 (LGWR switch) Current log# 2 seq# 1898 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 07:00:38 2012 Archived Log entry 1136 added for thread 1 sequence 1897 ID 0xe48db805 dest 1: Fri Nov 02 08:32:41 2012 Thread 1 cannot allocate new log, sequence 1899 Private strand flush not complete Current log# 2 seq# 1898 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1899 (LGWR switch) Current log# 3 seq# 1899 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 08:32:45 2012 Archived Log entry 1137 added for thread 1 sequence 1898 ID 0xe48db805 dest 1: Fri Nov 02 09:48:57 2012 Thread 1 advanced to log sequence 1900 (LGWR switch) Current log# 1 seq# 1900 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 09:48:58 2012 Archived Log entry 1138 added for thread 1 sequence 1899 ID 0xe48db805 dest 1: Fri Nov 02 10:18:15 2012 Thread 1 cannot allocate new log, sequence 1901 Private strand flush not complete Current log# 1 seq# 1900 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1901 (LGWR switch) Current log# 2 seq# 1901 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 10:18:19 2012 Archived Log entry 1139 added for thread 1 sequence 1900 ID 0xe48db805 dest 1: Fri Nov 02 10:22:58 2012 Thread 1 cannot allocate new log, sequence 1902 Private strand flush not complete Current log# 2 seq# 1901 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1902 (LGWR switch) Current log# 3 seq# 1902 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 10:23:02 2012 Archived Log entry 1140 added for thread 1 sequence 1901 ID 0xe48db805 dest 1: Fri Nov 02 10:27:38 2012 Thread 1 cannot allocate new log, sequence 1903 Checkpoint not complete Current log# 3 seq# 1902 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 cannot allocate new log, sequence 1903 Private strand flush not complete Current log# 3 seq# 1902 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1903 (LGWR switch) Current log# 1 seq# 1903 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 10:27:45 2012 Archived Log entry 1141 added for thread 1 sequence 1902 ID 0xe48db805 dest 1: Fri Nov 02 10:32:27 2012 Thread 1 cannot allocate new log, sequence 1904 Checkpoint not complete Current log# 1 seq# 1903 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 cannot allocate new log, sequence 1904 Private strand flush not complete Current log# 1 seq# 1903 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1904 (LGWR switch) Current log# 2 seq# 1904 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 10:32:34 2012 Archived Log entry 1142 added for thread 1 sequence 1903 ID 0xe48db805 dest 1: Fri Nov 02 10:35:42 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_15856.trc (incident=101353): ORA-03137: TTC protocol internal error : [12333] [8] [49] [50] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101353\siporex_ora_15856_i101353.trc Fri Nov 02 10:35:44 2012 Trace dumping is performing id=[cdmp_20121102103544] I don't know main reason of this issue as well as how to fixing it. Please help me.

    Read the article

  • A Rose by Any Other Name..

    - by Geoff N. Hiten
    It is always a good start when you can steal a title line from one of the best writers in the English language.  Let’s hope I can make the rest of this post live up to the opening.  One recurring problem with SQL server is moving databases to new servers.  Client applications use a variety of ways to resolve SQL Server names, some of which are not changed easily <cough SharePoint /cough>.  If you happen to be using default instances on both the source and target SQL Server, then the solution is pretty simple.  You create (or bug the network admin until she creates) two DNS “A” records. One points the old name to the new IP address.  The other creates a new alias for the old server, since the original system name is now redirected.  Note this will redirect ALL traffic from the old server to the new server, including RDP and file share connection attempts.    Figure 1 – Microsoft DNS MMC Snap-In   Figure 2 – DNS New Host Dialog Box Both records are necessary so you can still access the old server via an alternate name. Server Role IP Address Name Alias Source 10.97.230.60 SQL01 SQL01_Old Target 10.97.230.80 SQL02 SQL01 Table 1 – Alias List If you or somebody set up connections via IP address, you deserve to have to go to each app and fix it by hand.  That is the only way to fix that particular foul-up. If have to deal with Named Instances either as a source or a target, then it gets more complicated.  The standard fix is to use the SQL Server Configuration Manager (or one of its earlier incarnations) to create a SQL client alias to redirect the connection.  This can be a pain installing and configuring the app on multiple client servers.  The good news is that SQL Server Configuration Manager AND all of its earlier versions simply write a few registry keys.  Extracting the keys into a .reg file makes centralized automated deployment a snap. If the client is a 32-bit system, you have to extract the native key.  If it is a 64-bit, you have to extract the native key and the WoW (32 bit on 64 bit host) key. First, pick a development system to create the actual registry key.  If you do this repeatedly, you can simply edit an existing registry file.  Create the entry using the SQL Configuration Manager.  You must use a 64-bit system to create the WoW key.  The following example redirects from a named instance “SQL01\SQLUtiluty” to a default instance on “SQL02”.   Figure 3 – SQL Server Configuration Manager - Native Figure 3 shows the native key listing. Figure 4 – SQL Server Configuration Manager – WoW If you think you don’t need the WoW key because your app is 64 it, think again.  SQL Server Management Server is a 32-bit app, as are most SQL test utilities.  Always create both keys for 64-bit target systems. Now that the keys exist, we can extract them into a .reg file. Fire up REGEDIT and browse to the following location:  HKLM\Software\Microsoft\MSSQLServer\Client\ConnectTo.  You can also search the registry for the string value of one of the server names (old or new). Right click on the “ConnectTo” label and choose “Export”.  Save with an appropriate name and location.  The resulting file should look something like this: Figure 5 – SQL01_Alias.reg Repeat the process with the location: HKLM\Software\Wow6432Node\Microsoft\MSSQLServer\Client\ConnectTo Note that if you have multiple alias entries, ALL of the entries will be exported.  In that case, you can edit the file and remove the extra aliases. You can edit the files together into a single file.  Just leave a blank line between new keys like this: Figure 6 – SQL01_Alias_All.reg Of course if you have an automatic way to deploy, it makes sense to have an automatic way to Un-deploy.  To delete a registry key, simply edit the .reg file and replace the target with a “-“ sign like so. Figure 7 – SQL01_Alias_UNDO.reg Now we have the ability to move any database to any server without having to install or change any applications on any client server.  The whole process should be transparent to the applications, which makes planning and coordinating database moves a far simpler task.

    Read the article

  • C#/.NET Little Wonders: Fun With Enum Methods

    - by James Michael Hare
    Once again lets dive into the Little Wonders of .NET, those small things in the .NET languages and BCL classes that make development easier by increasing readability, maintainability, and/or performance. So probably every one of us has used an enumerated type at one time or another in a C# program.  The enumerated types we create are a great way to represent that a value can be one of a set of discrete values (or a combination of those values in the case of bit flags). But the power of enum types go far beyond simple assignment and comparison, there are many methods in the Enum class (that all enum types “inherit” from) that can give you even more power when dealing with them. IsDefined() – check if a given value exists in the enum Are you reading a value for an enum from a data source, but are unsure if it is actually a valid value or not?  Casting won’t tell you this, and Parse() isn’t guaranteed to balk either if you give it an int or a combination of flags.  So what can we do? Let’s assume we have a small enum like this for result codes we want to return back from our business logic layer: 1: public enum ResultCode 2: { 3: Success, 4: Warning, 5: Error 6: } In this enum, Success will be zero (unless given another value explicitly), Warning will be one, and Error will be two. So what happens if we have code like this where perhaps we’re getting the result code from another data source (could be database, could be web service, etc)? 1: public ResultCode PerformAction() 2: { 3: // set up and call some method that returns an int. 4: int result = ResultCodeFromDataSource(); 5:  6: // this will suceed even if result is < 0 or > 2. 7: return (ResultCode) result; 8: } So what happens if result is –1 or 4?  Well, the cast does not fail, so what we end up with would be an instance of a ResultCode that would have a value that’s outside of the bounds of the enum constants we defined. This means if you had a block of code like: 1: switch (result) 2: { 3: case ResultType.Success: 4: // do success stuff 5: break; 6:  7: case ResultType.Warning: 8: // do warning stuff 9: break; 10:  11: case ResultType.Error: 12: // do error stuff 13: break; 14: } That you would hit none of these blocks (which is a good argument for always having a default in a switch by the way). So what can you do?  Well, there is a handy static method called IsDefined() on the Enum class which will tell you if an enum value is defined.  1: public ResultCode PerformAction() 2: { 3: int result = ResultCodeFromDataSource(); 4:  5: if (!Enum.IsDefined(typeof(ResultCode), result)) 6: { 7: throw new InvalidOperationException("Enum out of range."); 8: } 9:  10: return (ResultCode) result; 11: } In fact, this is often recommended after you Parse() or cast a value to an enum as there are ways for values to get past these methods that may not be defined. If you don’t like the syntax of passing in the type of the enum, you could clean it up a bit by creating an extension method instead that would allow you to call IsDefined() off any isntance of the enum: 1: public static class EnumExtensions 2: { 3: // helper method that tells you if an enum value is defined for it's enumeration 4: public static bool IsDefined(this Enum value) 5: { 6: return Enum.IsDefined(value.GetType(), value); 7: } 8: }   HasFlag() – an easier way to see if a bit (or bits) are set Most of us who came from the land of C programming have had to deal extensively with bit flags many times in our lives.  As such, using bit flags may be almost second nature (for a quick refresher on bit flags in enum types see one of my old posts here). However, in higher-level languages like C#, the need to manipulate individual bit flags is somewhat diminished, and the code to check for bit flag enum values may be obvious to an advanced developer but cryptic to a novice developer. For example, let’s say you have an enum for a messaging platform that contains bit flags: 1: // usually, we pluralize flags enum type names 2: [Flags] 3: public enum MessagingOptions 4: { 5: None = 0, 6: Buffered = 0x01, 7: Persistent = 0x02, 8: Durable = 0x04, 9: Broadcast = 0x08 10: } We can combine these bit flags using the bitwise OR operator (the ‘|’ pipe character): 1: // combine bit flags using 2: var myMessenger = new Messenger(MessagingOptions.Buffered | MessagingOptions.Broadcast); Now, if we wanted to check the flags, we’d have to test then using the bit-wise AND operator (the ‘&’ character): 1: if ((options & MessagingOptions.Buffered) == MessagingOptions.Buffered) 2: { 3: // do code to set up buffering... 4: // ... 5: } While the ‘|’ for combining flags is easy enough to read for advanced developers, the ‘&’ test tends to be easy for novice developers to get wrong.  First of all you have to AND the flag combination with the value, and then typically you should test against the flag combination itself (and not just for a non-zero)!  This is because the flag combination you are testing with may combine multiple bits, in which case if only one bit is set, the result will be non-zero but not necessarily all desired bits! Thanks goodness in .NET 4.0 they gave us the HasFlag() method.  This method can be called from an enum instance to test to see if a flag is set, and best of all you can avoid writing the bit wise logic yourself.  Not to mention it will be more readable to a novice developer as well: 1: if (options.HasFlag(MessagingOptions.Buffered)) 2: { 3: // do code to set up buffering... 4: // ... 5: } It is much more concise and unambiguous, thus increasing your maintainability and readability. It would be nice to have a corresponding SetFlag() method, but unfortunately generic types don’t allow you to specialize on Enum, which makes it a bit more difficult.  It can be done but you have to do some conversions to numeric and then back to the enum which makes it less of a payoff than having the HasFlag() method.  But if you want to create it for symmetry, it would look something like this: 1: public static T SetFlag<T>(this Enum value, T flags) 2: { 3: if (!value.GetType().IsEquivalentTo(typeof(T))) 4: { 5: throw new ArgumentException("Enum value and flags types don't match."); 6: } 7:  8: // yes this is ugly, but unfortunately we need to use an intermediate boxing cast 9: return (T)Enum.ToObject(typeof (T), Convert.ToUInt64(value) | Convert.ToUInt64(flags)); 10: } Note that since the enum types are value types, we need to assign the result to something (much like string.Trim()).  Also, you could chain several SetFlag() operations together or create one that takes a variable arg list if desired. Parse() and ToString() – transitioning from string to enum and back Sometimes, you may want to be able to parse an enum from a string or convert it to a string - Enum has methods built in to let you do this.  Now, many may already know this, but may not appreciate how much power are in these two methods. For example, if you want to parse a string as an enum, it’s easy and works just like you’d expect from the numeric types: 1: string optionsString = "Persistent"; 2:  3: // can use Enum.Parse, which throws if finds something it doesn't like... 4: var result = (MessagingOptions)Enum.Parse(typeof (MessagingOptions), optionsString); 5:  6: if (result == MessagingOptions.Persistent) 7: { 8: Console.WriteLine("It worked!"); 9: } Note that Enum.Parse() will throw if it finds a value it doesn’t like.  But the values it likes are fairly flexible!  You can pass in a single value, or a comma separated list of values for flags and it will parse them all and set all bits: 1: // for string values, can have one, or comma separated. 2: string optionsString = "Persistent, Buffered"; 3:  4: var result = (MessagingOptions)Enum.Parse(typeof (MessagingOptions), optionsString); 5:  6: if (result.HasFlag(MessagingOptions.Persistent) && result.HasFlag(MessagingOptions.Buffered)) 7: { 8: Console.WriteLine("It worked!"); 9: } Or you can parse in a string containing a number that represents a single value or combination of values to set: 1: // 3 is the combination of Buffered (0x01) and Persistent (0x02) 2: var optionsString = "3"; 3:  4: var result = (MessagingOptions) Enum.Parse(typeof (MessagingOptions), optionsString); 5:  6: if (result.HasFlag(MessagingOptions.Persistent) && result.HasFlag(MessagingOptions.Buffered)) 7: { 8: Console.WriteLine("It worked again!"); 9: } And, if you really aren’t sure if the parse will work, and don’t want to handle an exception, you can use TryParse() instead: 1: string optionsString = "Persistent, Buffered"; 2: MessagingOptions result; 3:  4: // try parse returns true if successful, and takes an out parm for the result 5: if (Enum.TryParse(optionsString, out result)) 6: { 7: if (result.HasFlag(MessagingOptions.Persistent) && result.HasFlag(MessagingOptions.Buffered)) 8: { 9: Console.WriteLine("It worked!"); 10: } 11: } So we covered parsing a string to an enum, what about reversing that and converting an enum to a string?  The ToString() method is the obvious and most basic choice for most of us, but did you know you can pass a format string for enum types that dictate how they are written as a string?: 1: MessagingOptions value = MessagingOptions.Buffered | MessagingOptions.Persistent; 2:  3: // general format, which is the default, 4: Console.WriteLine("Default : " + value); 5: Console.WriteLine("G (default): " + value.ToString("G")); 6:  7: // Flags format, even if type does not have Flags attribute. 8: Console.WriteLine("F (flags) : " + value.ToString("F")); 9:  10: // integer format, value as number. 11: Console.WriteLine("D (num) : " + value.ToString("D")); 12:  13: // hex format, value as hex 14: Console.WriteLine("X (hex) : " + value.ToString("X")); Which displays: 1: Default : Buffered, Persistent 2: G (default): Buffered, Persistent 3: F (flags) : Buffered, Persistent 4: D (num) : 3 5: X (hex) : 00000003 Now, you may not really see a difference here between G and F because I used a [Flags] enum, the difference is that the “F” option treats the enum as if it were flags even if the [Flags] attribute is not present.  Let’s take a non-flags enum like the ResultCode used earlier: 1: // yes, we can do this even if it is not [Flags] enum. 2: ResultCode value = ResultCode.Warning | ResultCode.Error; And if we run that through the same formats again we get: 1: Default : 3 2: G (default): 3 3: F (flags) : Warning, Error 4: D (num) : 3 5: X (hex) : 00000003 Notice that since we had multiple values combined, but it was not a [Flags] marked enum, the G and default format gave us a number instead of a value name.  This is because the value was not a valid single-value constant of the enum.  However, using the F flags format string, it broke out the value into its component flags even though it wasn’t marked [Flags]. So, if you want to get an enum to display appropriately for whether or not it has the [Flags] attribute, use G which is the default.  If you always want it to attempt to break down the flags, use F.  For numeric output, obviously D or  X are the best choice depending on whether you want decimal or hex. Summary Hopefully, you learned a couple of new tricks with using the Enum class today!  I’ll add more little wonders as I think of them and thanks for all the invaluable input!   Technorati Tags: C#,.NET,Little Wonders,Enum,BlackRabbitCoder

    Read the article

  • The Joy Of Hex

    - by Jim Giercyk
    While working on a mainframe integration project, it occurred to me that some basic computer concepts are slipping into obscurity. For example, just about anyone can tell you that a 64-bit processor is faster than a 32-bit processer. A grade school child could tell you that a computer “speaks” in ‘1’s and ‘0’s. Some people can even tell you that there are 8 bits in a byte. However, I have found that even the most seasoned developers often can’t explain the theory behind those statements. That is not a knock on programmers; in the age of IntelliSense, what reason do we have to work with data at the bit level? Many computer theory classes treat bit-level programming as a thing of the past, no longer necessary now that storage space is plentiful. The trouble with that mindset is that the world is full of legacy systems that run programs written in the 1970’s.  Today our jobs require us to extract data from those systems, regardless of the format, and that often involves low-level programming. Because it seems knowledge of the low-level concepts is waning in recent times, I thought a review would be in order.       CHARACTER: See Spot Run HEX: 53 65 65 20 53 70 6F 74 20 52 75 6E DECIMAL: 83 101 101 32 83 112 111 116 32 82 117 110 BINARY: 01010011 01100101 01100101 00100000 01010011 01110000 01101111 01110100 00100000 01010010 01110101 01101110 In this example, I have broken down the words “See Spot Run” to a level computers can understand – machine language.     CHARACTER:  The character level is what is rendered by the computer.  A “Character Set” or “Code Page” contains 256 characters, both printable and unprintable.  Each character represents 1 BYTE of data.  For example, the character string “See Spot Run” is 12 Bytes long, exclusive of the quotation marks.  Remember, a SPACE is an unprintable character, but it still requires a byte.  In the example I have used the default Windows character set, ASCII, which you can see here:  http://www.asciitable.com/ HEX:  Hex is short for hexadecimal, or Base 16.  Humans are comfortable thinking in base ten, perhaps because they have 10 fingers and 10 toes; fingers and toes are called digits, so it’s not much of a stretch.  Computers think in Base 16, with numeric values ranging from zero to fifteen, or 0 – F.  Each decimal place has a possible 16 values as opposed to a possible 10 values in base 10.  Therefore, the number 10 in Hex is equal to the number 16 in Decimal.  DECIMAL:  The Decimal conversion is strictly for us humans to use for calculations and conversions.  It is much easier for us humans to calculate that [30 – 10 = 20] in decimal than it is for us to calculate [1E – A = 14] in Hex.  In the old days, an error in a program could be found by determining the displacement from the entry point of a module.  Since those values were dumped from the computers head, they were in hex. A programmer needed to convert them to decimal, do the equation and convert back to hex.  This gets into relative and absolute addressing, a topic for another day.  BINARY:  Binary, or machine code, is where any value can be expressed in 1s and 0s.  It is really Base 2, because each decimal place can have a possibility of only 2 characters, a 1 or a 0.  In Binary, the number 10 is equal to the number 2 in decimal. Why only 1s and 0s?  Very simply, computers are made up of lots and lots of transistors which at any given moment can be ON ( 1 ) or OFF ( 0 ).  Each transistor is a bit, and the order that the transistors fire (or not fire) is what distinguishes one value from  another in the computers head (or CPU).  Consider 32 bit vs 64 bit processing…..a 64 bit processor has the capability to read 64 transistors at a time.  A 32 bit processor can only read half as many at a time, so in theory the 64 bit processor should be much faster.  There are many more factors involved in CPU performance, but that is the fundamental difference.    DECIMAL HEX BINARY 0 0 0000 1 1 0001 2 2 0010 3 3 0011 4 4 0100 5 5 0101 6 6 0110 7 7 0111 8 8 1000 9 9 1001 10 A 1010 11 B 1011 12 C 1100 13 D 1101 14 E 1110 15 F 1111   Remember that each character is a BYTE, there are 2 HEX characters in a byte (called nibbles) and 8 BITS in a byte.  I hope you enjoyed reading about the theory of data processing.  This is just a high-level explanation, and there is much more to be learned.  It is safe to say that, no matter how advanced our programming languages and visual studios become, they are nothing more than a way to interpret bits and bytes.  There is nothing like the joy of hex to get the mind racing.

    Read the article

  • Atheros Wireless card shows up as two different models?

    - by geermc4
    Hi I've been fighting these wireless drivers for a few days and just recently i noticed that the model the Wireless controller appears in lspci is different sometimes. This is the data i have after installing Ubuntu Server 64 bit ~# lspci -k .... 04:00.0 Network controller: Atheros Communications Inc. AR9285 Wireless Network Adapter (PCI-Express) (rev 01) Subsystem: AzureWave Device 1d89 Kernel driver in use: ath9k Kernel modules: ath9k ran some updates, restarted, all was good, all though it did say that linux-headers-server linux-image-server linux-server where beeing kept back. After that i installed ubuntu-desktop (aptitude install ubuntu-desktop --without-recommends) restarted and not only is the wireless not working anymore, but the hardware is listed as a different card ~# lspci -k .... 04:00.0 Ethernet controller: Atheros Communications Inc. AR5008 Wireless Network Adapter (rev 01) has no available drivers for it, still i tried to modprobe ath9k, they show up in lsmod as loaded, but still iw list shows nothing. this is what it looked like before the ubuntu-desktop instalation Wiphy phy0 Band 1: Capabilities: 0x11ce HT20/HT40 SM Power Save disabled RX HT40 SGI TX STBC RX STBC 1-stream Max AMSDU length: 3839 bytes DSSS/CCK HT40 Maximum RX AMPDU length 65535 bytes (exponent: 0x003) Minimum RX AMPDU time spacing: 8 usec (0x06) HT TX/RX MCS rate indexes supported: 0-7 Frequencies: * 2412 MHz [1] (14.0 dBm) * 2417 MHz [2] (15.0 dBm) * 2422 MHz [3] (15.0 dBm) * 2427 MHz [4] (15.0 dBm) * 2432 MHz [5] (15.0 dBm) * 2437 MHz [6] (15.0 dBm) * 2442 MHz [7] (15.0 dBm) * 2447 MHz [8] (15.0 dBm) * 2452 MHz [9] (15.0 dBm) * 2457 MHz [10] (15.0 dBm) * 2462 MHz [11] (15.0 dBm) * 2467 MHz [12] (15.0 dBm) (passive scanning) * 2472 MHz [13] (14.0 dBm) (passive scanning) * 2484 MHz [14] (17.0 dBm) (passive scanning) Bitrates (non-HT): * 1.0 Mbps * 2.0 Mbps (short preamble supported) * 5.5 Mbps (short preamble supported) * 11.0 Mbps (short preamble supported) * 6.0 Mbps * 9.0 Mbps * 12.0 Mbps * 18.0 Mbps * 24.0 Mbps * 36.0 Mbps * 48.0 Mbps * 54.0 Mbps max # scan SSIDs: 4 max scan IEs length: 2257 bytes Coverage class: 0 (up to 0m) Supported Ciphers: * WEP40 (00-0f-ac:1) * WEP104 (00-0f-ac:5) * TKIP (00-0f-ac:2) * CCMP (00-0f-ac:4) * CMAC (00-0f-ac:6) Available Antennas: TX 0x1 RX 0x3 Configured Antennas: TX 0x1 RX 0x3 Supported interface modes: * IBSS * managed * AP * AP/VLAN * WDS * monitor * mesh point * P2P-client * P2P-GO software interface modes (can always be added): * AP/VLAN * monitor interface combinations are not supported Supported commands: * new_interface * set_interface * new_key * new_beacon * new_station * new_mpath * set_mesh_params * set_bss * authenticate * associate * deauthenticate * disassociate * join_ibss * join_mesh * remain_on_channel * set_tx_bitrate_mask * action * frame_wait_cancel * set_wiphy_netns * set_channel * set_wds_peer * connect * disconnect Supported TX frame types: * IBSS: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * managed: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * AP: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * AP/VLAN: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * mesh point: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * P2P-client: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 * P2P-GO: 0x0000 0x0010 0x0020 0x0030 0x0040 0x0050 0x0060 0x0070 0x0080 0x0090 0x00a0 0x00b0 0x00c0 0x00d0 0x00e0 0x00f0 Supported RX frame types: * IBSS: 0x00d0 * managed: 0x0040 0x00d0 * AP: 0x0000 0x0020 0x0040 0x00a0 0x00b0 0x00c0 0x00d0 * AP/VLAN: 0x0000 0x0020 0x0040 0x00a0 0x00b0 0x00c0 0x00d0 * mesh point: 0x00b0 0x00c0 0x00d0 * P2P-client: 0x0040 0x00d0 * P2P-GO: 0x0000 0x0020 0x0040 0x00a0 0x00b0 0x00c0 0x00d0 Device supports RSN-IBSS. What's with the hardware change? If it has 2, how can i make the AR9285 always load and disable AR5008, or, is it the same and it's just showing it different? :| Oh and I've tried this on Ubuntu 10.04 server, xubuntu 12.04, ubuntu 12.04 desktop and server. Thanks in advanced. -- Here's some more info, i have it setup in 2 hard drives, 1 works and the other one i'm using to figure it out The one that works... # lshw -class network *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 06 serial: 54:04:a6:a3:3b:96 size: 1Gbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl_nic/rtl8168e-2.fw ip=192.168.2.147 latency=0 link=yes multicast=yes port=MII speed=1Gbit/s resources: irq:43 ioport:e000(size=256) memory:d0004000-d0004fff memory:d0000000-d0003fff *-network description: Wireless interface product: AR9285 Wireless Network Adapter (PCI-Express) vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:04:00.0 logical name: wlan0 version: 01 serial: 74:2f:68:4a:26:73 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=ath9k driverversion=3.2.0-18-generic-pae firmware=N/A latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:18 memory:fea00000-fea0ffff Here's where it doesn't # lshw -class network *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 06 serial: 54:04:a6:a3:3b:96 size: 1Gbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl_nic/rtl8168e-2.fw ip=192.168.2.160 latency=0 link=yes multicast=yes port=MII speed=1Gbit/s resources: irq:43 ioport:e000(size=256) memory:d0004000-d0004fff memory:d0000000-d0003fff *-network UNCLAIMED description: Ethernet controller product: AR5008 Wireless Network Adapter vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:04:00.0 version: 01 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: latency=0 resources: memory:fea00000-fea0ffff Update I've noticed that if i blacklist the ath9k and ath9k_common modules lspci gives me the AR9285, but then I need to modprobe ath9k for it to work, does this make any sense? If so, why?

    Read the article

  • Oracle Enterprise Manager Cloud Control 12c Release 2 (12.1.0.2) is Available Now !

    - by Anand Akela
    Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman","serif";} Oracle today announced the availability of Oracle Enterprise Manager Cloud Control 12c Release 2 (12.1.0.2). It is now available for download on OTN on ALL platforms. This is the first major release since the launch of Enterprise Manager 12c in October of 2011. This is the first time when Enterprise Manager release is available on all platforms simultaneously. This is primarily a stability release which incorporates many of issues and feedback reported by early adopters. In addition, this release contains many new features and enhancements in areas across the board. New Capabilities and Features Enhanced management capabilities for enterprise private clouds: Introduces new capabilities to allow customers to build and manage a Java Platform-as-a-Service (PaaS) cloud based on Oracle Weblogic Server. The new capabilities include guided set up of PaaS Cloud, self-service provisioning, automatic scale out and metering and chargeback. Enhanced lifecycle management capabilities for Oracle WebLogic Server environments: Combining in-context multiple domain, patching and configuration file synchronizations. Integrated Hardware-Software management for Oracle Exalogic Elastic Cloud through features such as rack schematics visualization and integrated monitoring of all hardware and software components. The latest management capabilities for business-critical applications include: Business Application Management: A new Business Application (BA) target type and dashboard with flexible definitions provides a logical view of an application’s business transactions, end-user experiences and the cloud infrastructure the monitored application is running on. Enhanced User Experience Reporting: Oracle Real User Experience Insight has been enhanced to provide reporting capabilities on client-side issues for applications running in the cloud and has been more tightly coupled with Oracle Business Transaction Management to help ensure that real-time user experience and transaction tracing data is provided to users in context. Several key improvements address ease of administration, reporting and extensibility for massively scalable cloud environments including dynamic groups, self-updateable monitoring templates, bulk operations against many events, etc. New and Revised Plug-Ins: Several plug-Ins have been updated as a part of this release resulting in either new versions or revisions. Revised plug-ins contain only bug-fixes and while new plug-ins incorporate both bug fixes as well as new functionality. Plug-In Name Version Enterprise Manager for Oracle Database 12.1.0.2 (revision) Enterprise Manager for Oracle Fusion Middleware 12.1.0.3 (new) Enterprise Manager for Chargeback and Capacity Planning 12.1.0.3 (new) Enterprise Manager for Oracle Fusion Applications 12.1.0.3 (new) Enterprise Manager for Oracle Virtualization 12.1.0.3 (new) Enterprise Manager for Oracle Exadata 12.1.0.3 (new) Enterprise Manager for Oracle Cloud 12.1.0.4 (new) Installation and Upgrade: All major platforms have been released simultaneously (Linux 32 / 64 bit, Solaris (SPARC), Solaris x86-64, IBM AIX 64-bit, and Windows x86-64 (64-bit) ) Enterprise Manager 12.1.0.2 is a complete release that includes both the EM OMS and Agent versions of 12.1.0.2. Installation options available with EM 12.1.0.2: User can do fresh Install or an upgrade from versions EM 10.2.0.5, 11.1, or 12.1.0.2 ( Bundle Patch 1 not mandatory). Upgrading to EM 12.1.0.2 from EM 12.1.0.1 is not a patch application (similar to Bundle Patch 1) but is achieved through a 1-system upgrade. Documentation: Oracle Enterprise Manager Cloud Control Introduction Document provides a broad overview of capabilities and highlights"What's New" in EM 12.1.0.2. All updated Oracle Enterprise Manager documentation can be found on OTN Upgrade Guide Please feel free to ask questions related to the new Oracle Enterprise Manager Cloud Control 12c Release 2 (12.1.0.2) at the Oracle Enterprise Manager Forum . You could also share your feedback at twitter  using hash tag #em12c or at Facebook . Stay Connected: Twitter |  Face book |  You Tube |  Linked in |  Newsletter

    Read the article

  • Why 32-bit color EGL configurations fail with EGL_BAD_MATCH on Moto Droid?

    - by Gilead
    I'm trying to figure out why certain EGL configurations cause eglMakeCurrent() call to return EGL_BAD_MATCH on Motorola Droid running Android 2.1u1. This is a full list of hardware-accelerated EGL configurations (those with EGL_CONFIG_CAVEAT == EGL_NONE) as there's a few others with EGL_CONFIG_CAVEAT == EGL_SLOW_CONFIG but those are backed by PixelFlinger 1.2 meaning they're using software renderer. ID: 0 RGB: 8, 8, 8 Alpha: 8 Depth: 24 Stencil: 8 // BAD MATCH ID: 1 RGB: 8, 8, 8 Alpha: 8 Depth: 0 Stencil: 0 // BAD MATCH ID: 2 RGB: 8, 8, 8 Alpha: 8 Depth: 24 Stencil: 8 // BAD MATCH ID: 3 RGB: 8, 8, 8 Alpha: 8 Depth: 24 Stencil: 8 // BAD MATCH ID: 4 RGB: 8, 8, 8 Alpha: 8 Depth: 0 Stencil: 0 // BAD MATCH ID: 5 RGB: 8, 8, 8 Alpha: 8 Depth: 24 Stencil: 8 // BAD MATCH ID: 6 RGB: 5, 6, 5 Alpha: 0 Depth: 24 Stencil: 8 ID: 7 RGB: 5, 6, 5 Alpha: 0 Depth: 0 Stencil: 0 ID: 8 RGB: 5, 6, 5 Alpha: 0 Depth: 24 Stencil: 8 Clearly, all configurations with 32-bit color depth fail and all 16-bit ones are OK but: 1. Why? 2. WHY?! :) 3. How do I tell which ones would fail before actually trying to use them? The code below is as simple as it can get. I put if (v[0] == 6) there to check different configs, normally they're chosen by half-clever config matcher :) private void createSurface(SurfaceHolder holder) { egl = (EGL10)EGLContext.getEGL(); eglDisplay = egl.eglGetDisplay(EGL10.EGL_DEFAULT_DISPLAY); egl.eglInitialize(eglDisplay, null); int[] numConfigs = new int[1]; egl.eglChooseConfig(eglDisplay, new int[] { EGL10.EGL_NONE }, null, 0, numConfigs); EGLConfig[] configs = new EGLConfig[numConfigs[0]]; egl.eglChooseConfig(eglDisplay, new int[] { EGL10.EGL_NONE }, configs, numConfigs[0], numConfigs); int[] v = new int[1]; for (EGLConfig c : configs) { egl.eglGetConfigAttrib(eglDisplay, c, EGL10.EGL_CONFIG_ID, v); if (v[0] == 6) { eglConfig = c; } } eglContext = egl.eglCreateContext(eglDisplay, eglConfig, EGL10.EGL_NO_CONTEXT, null); if (eglContext == null || eglContext == EGL10.EGL_NO_CONTEXT) { throw new RuntimeException("Unable to create EGL context"); } eglSurface = egl.eglCreateWindowSurface(eglDisplay, eglConfig, holder, null); if (eglSurface == null || eglSurface == EGL10.EGL_NO_SURFACE) { throw new RuntimeException("Unable to create EGL surface"); } if (!egl.eglMakeCurrent(eglDisplay, eglSurface, eglSurface, eglContext)) { throw new RuntimeException("Unable to make EGL current"); } gl = (GL10)eglContext.getGL(); }

    Read the article

  • Any downsides to UPX-ing my 32-bit Python 2.6.4 development environment EXE/PYD/DLL files?

    - by Malcolm
    Are there any downsides to UPX-ing my 32-bit Python 2.6.4 development environment EXE/PYD/DLL files? The reason I'm asking is that I frequently use a custom PY2EXE script that UPX's copies of these files on every build. Yes, I could get fancy and try to cache UPXed files, but I think a simpler, safer, and higher performance solution would be for me to just UPX my Python 2.6.4 directory once and be done with it. Thoughts? Malcolm

    Read the article

< Previous Page | 89 90 91 92 93 94 95 96 97 98 99 100  | Next Page >