  • How to prevent response to who-has requests on virtual eth interface?

    - by user42881
    Hi, we use small embedded X86 linux servers equipped with a single physical ethernet port as a gateway for an IP video surveillance application. Each downstream IP cam is mapped to a separate virtual IP address like this: real eth0 IP address= 192.168.1.1, camera 1 (eth0:1) =192.168.1.61, camera 2 (eth0:2) =192.168.1.62, etc. etc. all on the same eth0 physical port. This approach works well, except that a specific third-party windows video recording application running on a separate PC on the same LAN, automatically pings the virtual IPs looking for unique who-has responses on system startup and, when it gets back the same eth0 MAC address for each virtual interface, freaks out and won't allow us to subsequently manually enter those addresses. The windows app doesn't mind, tho, if it receives no answer to the who-has ping. My question - how can we either (a) shut off the who-has responses just for the virtual eth0:x interfaces while keeping them for the primary physical eth0 port, or, in the alternative, spoof a valid but different MAC address for each virtual interface? Thanks!

    Read the article

  • SQL Server: Network pauses after installing cheap SATA card: Is there a solution?

    - by samsmith
    At the risk of being assigned to the "bad DBA" club... I did something desperate, and may have to undo it. Problem: After installing a low cost eSATA board, my SQL Server is intermittently unresponsive (seemingly when there is a lot of IO to the eSATA drive). Questions: 1) Is there a solution to the intermittent unresponsiveness that allows me to keep the eSATA in place? 2) Whether or not (1==true): What is a decent, low cost way to add 1-3 TB storage to SQL for non-critical SQL DBs? Detail: Our SAN is full, and expanding it is costly and will take a month. I have a pressing need to add 1-3 TB for some development DBs (e.g. not mission critical; data loss is OK). As a bandaid, I threw a $20 eSATA PCI board in the Dell 1950 server, and attached an external 2TB eSATA drive. This seemed to work fine, but I notice that our production SQL DBs, and even remote desktop, now experience network "pauses" that they never did before (with both SQL client apps and remote desktop throwing "networking problem" errors). This SQL Server has lots of memory, and runs an instance of SQL 2005 (where all line of business apps reside) and an instance SQL 2008 (for development db's). SQL Server RAM has been appropriately configured, and this setup has run great for years. The server is: Dell 1950 Win2003 x64 14GB RAM PERC controller, 2 mirrored hd's internal Dell SAN over gbit ethernet, dual homed 2 PCIx slots (1 used by NIC for SAN, 1 now in use for eSATA board) Thank you for suggestions!

    Read the article

  • Cannot connect to a shared network drive

    - by dublintech
    I am using windows 7, I cannot connect to a shared network drive on another machine. I can ping the machine. I can remote desktop connect to the machine. The machine is on the same subnet My friend with the exact same laptop as me (and on the same network, same workgroup) can connect to the shared folder. The machine I am trying to connect to and my friends machine can both see shared folders on my machine. I also cannot see shared folders on the friends laptop. When I select diagnose, windows tells me nothing useful. When I select see details on the error pop up, I see: Error code: 0x80004005 (google doesn't help much) I can nbtstat -a the machine who has the shared folder. When I try with my firewall turned off the same happens. I have ensured my windows 7 has all updates. I run security essentials to ensure my laptop is clean. I run ccleaner to clean up my registry. Same error. I have tried with my laptop on both wireless and ethernet. As you can imagine, I am banging my head against the wall on this one.

    Read the article

  • MAC-Address based routing

    - by d-fens
    Here is what i want to do: I have a bunch of systems, some might have the same Public-IP, i disable ARP. I have a Firewall (either IP Layer or bridge-FW) between these systems and the internet. Depending on the destination port of incoming IP-Packets to some of these Public-IPs i want to set the destinsation-Ethernet-Adress. So for instance System A has IP 8.8.8.8, mac de:ad:be:ef:de:ad, arp disabled System B has IP 8.8.8.8, mac 1f:1f:1f:1f:1f:1f, arp disabled Firewall has IP 8.8.8.1, arp disabled on that interface Incoming packet to IP 8.8.8.8 tcp dest port 100 Incoming packet to IP 8.8.8.8 tcp dest port 101 Firewall sets dest-mac for 1.) - de:ad:be:ef:de:ad Firewall sets dest-mac for 2.) - 1f:1f:1f:1f:1f:1f Second scenario: System A and System B establish outgoing TCP-Connections, and the firewall matches the dst-mac of the incoming IP-Packets (response packets) to the senders-mac address. is this possible in any way with linux and iptables? edit: i read ebtables might "work" in a hackish way for this purpose but i am not sure...

    Read the article

  • How to set up vpn tunnel (ipsec) connection

    - by Alfwed
    I'm working with a client who wants to set up a vpn tunnel between their network and ours. They're in charge of the tunnel and to give us the access they are asking me my public IP and my LAN IP. This is what i've got when i do an ifconfig on the server i will use to connect to the vpn $ ifconfig eth0 Link encap:Ethernet HWaddr d4:ae:52:cd:xx:xx inet adr:62.210.xxx.xxx Bcast:62.210.xxx.xxx Masque:255.255.255.0 adr inet6: fe80::d6ae:52ff:xxxx:xx/64 Scope:Lien UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 Packets reçus:55255032 erreurs:0 :779628 overruns:0 frame:0 TX packets:5419527 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 lg file transmission:1000 Octets reçus:5598164393 (5.5 GB) Octets transmis:1034297288 (1.0 GB) Interruption:16 Mémoire:c0000000-c0012800 lo Link encap:Boucle locale inet adr:127.0.0.1 Masque:255.0.0.0 adr inet6: ::1/128 Scope:Hôte UP LOOPBACK RUNNING MTU:16436 Metric:1 Packets reçus:45923382 erreurs:0 :0 overruns:0 frame:0 TX packets:45923382 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 lg file transmission:0 The inet adr:62.210.xxx.xxx is my public IP but it seems like i dont have any LAN IP. Can the connection work without LAN IP or should I create a private network somehow?

    Read the article

  • Wireless connection silently dies randomly

    - by Force Flow
    I have two WAP4410N wireless access points powered using Power-Over-Ethernet. They are both connected to the same LAN and broadcasting the same SSID with a WPA2 password. One is using channel 1, while the other is using channel 11. There is coverage overlap where the signal from both access points hover around -75db to -85db while standing in the same physical location. DHCP is disabled, and is being provided by another network device. Every day or so, devices can connect and authenticate to the access points, but are not granted an IP address (and subsequently are unable access to the LAN or Internet). For devices that had already retrieved an IP address prior to the issue exhibiting itself, the devices simply stop communicating with LAN and Internet. However, I can still access each access point's web admin interface from the LAN. If I reboot both devices, the problem vanishes and devices are once again able to get an IP address and connect to the LAN and Internet. Are these symptoms of signal interference between the two WAPs or is this a completely different issue?

    Read the article

  • VMWare server: virtual machine start-up reaches 95% and hangs

    - by Magsol
    This problem cropped up today, after updating my eVGA motherboard's chipset in order to try and fix an unrelated issue. After installing the chipset update (contained SATA and Ethernet drivers), every time I've tried to start my Ubuntu VM, it reaches 95% in the web interface and then just hangs. I'm using VMWare Server 2.0.2, running it within Windows 7 64-bit. I haven't had any issues up until now, and I suspect it has something to do with the chipset update. I've already tried reinstalling VMWare itself, removing the VM from the inventory and re-adding it, and neither has proved successful. I'm also not sure how to kill the VMware server process itself once the start-up hangs; I've only been able to try again by rebooting (as none of the VMWare Services listed kill the server process itself). Any insights? Edit: Uhhh...as an addendum: I have a cron job set up on my Ubuntu VM that runs every 20 minutes. The VM is still listed in the VMWare web interface as at 95% of startup, and the start/stop buttons are still disabled, but the cronjob just ran. I also tested SSH, and I was able to tunnel into the Ubuntu VM as well. Now I'm really confused. Edit #2: I just started a thread on the VMWare Server support forums on this same topic. Hopefully between the two communities, we can come up with an answer: http://communities.vmware.com/thread/251033 Edit #3: In lieu of a specific fix, I've switched over to VirtualBox, and all is working just fine.

    Read the article

  • Ping "replies" from same computer with 'Destination host unreachable' (no route to other computer)

    - by Srekel
    I've got two computers in a LAN behind a wireless router. One has XP with ip 192.168.1.2 This one has W7 with ip 192.168.1.7 If I try to ping the other one from this computer, I get this: C:\Users\Srekel>ping 192.168.1.2 Pinging 192.168.1.2 with 32 bytes of data: Reply from 192.168.1.7: Destination host unreachable. Reply from 192.168.1.7: Destination host unreachable. Reply from 192.168.1.7: Destination host unreachable. Reply from 192.168.1.7: Destination host unreachable. Ping statistics for 192.168.1.2: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Tracert gives the same result: C:\Users\Srekel>tracert 192.168.1.2 Tracing route to 192.168.1.2 over a maximum of 30 hops 1 Kakburken4 [192.168.1.7] reports: Destination host unreachable. Trace complete. Although I can ping and tracert the router without any problems. I have disabled the firewalls on both computers. The router is set to use DHCP (if that matters). Here is the output from "route". C:\Users\Srekel>route print =========================================================================== Interface List 13...00 25 86 df c6 89 ......TP-LINK Wireless N Adapter 12...e0 cb 4e 26 b9 84 ......Realtek PCIe GBE Family Controller #2 11...e0 cb 4e 26 be 94 ......Realtek PCIe GBE Family Controller 1...........................Software Loopback Interface 1 16...00 00 00 00 00 00 00 e0 Microsoft ISATAP Adapter #2 14...00 00 00 00 00 00 00 e0 Teredo Tunneling Pseudo-Interface =========================================================================== IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 0.0.0.0 0.0.0.0 192.168.1.1 192.168.1.7 20 127.0.0.0 255.0.0.0 On-link 127.0.0.1 306 127.0.0.1 255.255.255.255 On-link 127.0.0.1 306 127.255.255.255 255.255.255.255 On-link 127.0.0.1 306 192.168.1.0 255.255.255.0 On-link 192.168.1.7 276 192.168.1.7 255.255.255.255 On-link 192.168.1.7 276 192.168.1.255 255.255.255.255 On-link 192.168.1.7 276 224.0.0.0 240.0.0.0 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 192.168.1.7 276 255.255.255.255 255.255.255.255 On-link 127.0.0.1 306 255.255.255.255 255.255.255.255 On-link 192.168.1.7 276 =========================================================================== Persistent Routes: None IPv6 Route Table =========================================================================== Active Routes: If Metric Network Destination Gateway 14 58 ::/0 On-link 1 306 ::1/128 On-link 14 58 2001::/32 On-link 14 306 2001:0:5ef5:73ba:881:20c1:3f57:fef8/128 On-link 14 306 fe80::/64 On-link 14 306 fe80::881:20c1:3f57:fef8/128 On-link 1 306 ff00::/8 On-link 14 306 ff00::/8 On-link =========================================================================== Persistent Routes: None I've set up and debugged a few networks in my life but I'm not really an advanced network user, so I'm not sure what might be wrong. Any ideas? Oh, and pinging this computer from the other computer doesn't work either. EDIT: Adding arp output: C:\Users\Srekel>arp -a Interface: 192.168.1.7 --- 0xd Internet Address Physical Address Type 192.168.1.1 00-1f-33-ef-28-01 dynamic 192.168.1.255 ff-ff-ff-ff-ff-ff static 224.0.0.22 01-00-5e-00-00-16 static 224.0.0.252 01-00-5e-00-00-fc static 239.255.255.250 01-00-5e-7f-ff-fa static 255.255.255.255 ff-ff-ff-ff-ff-ff static Adding ipconfig... C:\Users\Srekel>ipconfig /all Windows IP Configuration Host Name . . . . . . . . . . . . : Kakburken4 Primary Dns Suffix . . . . . . . : Node Type . . . . . . . . . . . . : Hybrid IP Routing Enabled. . . . . . . . : No WINS Proxy Enabled. . . . . . . . : No Wireless LAN adapter Wireless Network Connection: Connection-specific DNS Suffix . : Description . . . . . . . . . . . : TP-LINK Wireless N Adapter Physical Address. . . . . . . . . : 00-25-86-DF-C6-89 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes IPv4 Address. . . . . . . . . . . : 192.168.1.7(Preferred) Subnet Mask . . . . . . . . . . . : 255.255.255.0 Lease Obtained. . . . . . . . . . : 09 April 2010 23:09:45 Lease Expires . . . . . . . . . . : 10 April 2010 23:09:45 Default Gateway . . . . . . . . . : 192.168.1.1 DHCP Server . . . . . . . . . . . : 192.168.1.1 DNS Servers . . . . . . . . . . . : 192.168.1.1 NetBIOS over Tcpip. . . . . . . . : Enabled Ethernet adapter Local Area Connection 2: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Realtek PCIe GBE Family Controller #2 Physical Address. . . . . . . . . : E0-CB-4E-26-B9-84 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes Ethernet adapter Local Area Connection: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Realtek PCIe GBE Family Controller Physical Address. . . . . . . . . : E0-CB-4E-26-BE-94 DHCP Enabled. . . . . . . . . . . : Yes Autoconfiguration Enabled . . . . : Yes Tunnel adapter isatap.{74D5C406-894E-4000-8DE7-6AAEBF7C8382}: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Microsoft ISATAP Adapter #2 Physical Address. . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes Tunnel adapter Teredo Tunneling Pseudo-Interface: Connection-specific DNS Suffix . : Description . . . . . . . . . . . : Teredo Tunneling Pseudo-Interface Physical Address. . . . . . . . . : 00-00-00-00-00-00-00-E0 DHCP Enabled. . . . . . . . . . . : No Autoconfiguration Enabled . . . . : Yes IPv6 Address. . . . . . . . . . . : 2001:0:5ef5:73ba:881:20c1:3f57:fef8(Preferred) Link-local IPv6 Address . . . . . : fe80::881:20c1:3f57:fef8%14(Preferred) Default Gateway . . . . . . . . . : :: NetBIOS over Tcpip. . . . . . . . : Disabled

    Read the article

  • Tips / techniques for high-performance C# server sockets

    - by McKenzieG1
    I have a .NET 2.0 server that seems to be running into scaling problems, probably due to poor design of the socket-handling code, and I am looking for guidance on how I might redesign it to improve performance. Usage scenario: 50 - 150 clients, high rate (up to 100s / second) of small messages (10s of bytes each) to / from each client. Client connections are long-lived - typically hours. (The server is part of a trading system. The client messages are aggregated into groups to send to an exchange over a smaller number of 'outbound' socket connections, and acknowledgment messages are sent back to the clients as each group is processed by the exchange.) OS is Windows Server 2003, hardware is 2 x 4-core X5355. Current client socket design: A TcpListener spawns a thread to read each client socket as clients connect. The threads block on Socket.Receive, parsing incoming messages and inserting them into a set of queues for processing by the core server logic. Acknowledgment messages are sent back out over the client sockets using async Socket.BeginSend calls from the threads that talk to the exchange side. Observed problems: As the client count has grown (now 60-70), we have started to see intermittent delays of up to 100s of milliseconds while sending and receiving data to/from the clients. (We log timestamps for each acknowledgment message, and we can see occasional long gaps in the timestamp sequence for bunches of acks from the same group that normally go out in a few ms total.) Overall system CPU usage is low (< 10%), there is plenty of free RAM, and the core logic and the outbound (exchange-facing) side are performing fine, so the problem seems to be isolated to the client-facing socket code. There is ample network bandwidth between the server and clients (gigabit LAN), and we have ruled out network or hardware-layer problems. Any suggestions or pointers to useful resources would be greatly appreciated. If anyone has any diagnostic or debugging tips for figuring out exactly what is going wrong, those would be great as well. Note: I have the MSDN Magazine article Winsock: Get Closer to the Wire with High-Performance Sockets in .NET, and I have glanced at the Kodart "XF.Server" component - it looks sketchy at best.

    Read the article

  • Stored procedure performance randomly plummets; trivial ALTER fixes it. Why?

    - by gWiz
    I have a couple of stored procedures on SQL Server 2005 that I've noticed will suddenly take a significantly long time to complete when invoked from my ASP.NET MVC app running in an IIS6 web farm of four servers. Normal, expected completion time is less than a second; unexpected anomalous completion time is 25-45 seconds. The problem doesn't seem to ever correct itself. However, if I ALTER the stored procedure (even if I don't change anything in the procedure, except to perhaps add a space to the script created by SSMS Modify command), the completion time reverts to expected completion time. IIS and SQL Server are running on separate boxes, both running Windows Server 2003 R2 Enterprise Edition. SQL Server is Standard Edition. All machines have dual Xeon E5450 3GHz CPUs and 4GB RAM. SQL Server is accessed using its TCP/IP protocol over gigabit ethernet (not sure what physical medium). The problem is present from all web servers in the web farm. When I invoke the procedure from a query window in SSMS on my development machine, the procedure completes in normal time. This is strange because I was under the impression that SSMS used the same SqlClient driver as in .NET. When I point my development instance of the web app to the production database, I again get the anomalous long completion time. If my SqlCommand Timeout is too short, I get System.Data.SqlClient.SqlException: Timeout expired. The timeout period elapsed prior to completion of the operation or the server is not responding. Question: Why would performing ALTER on the stored procedure, without actually changing anything in it, restore the completion time to less than a second, as expected? Edit: To clarify, when the procedure is running slow for the app, it simultaneously runs fine in SSMS with the same parameters. The only difference I can discern is login credentials (next time I notice the behavior, I'll be checking from SSMS with the same creds). The ultimate goal is to get the procs to sustainably run with expected speed without requiring occasional intervention. Resolution: I wanted to to update this question in case others are experiencing this issue. Following the leads of the answers below, I was able to consistently reproduce this behavior. In order to test, I utilize sp_recompile and pass it one of the susceptible sprocs. I then initiate a website request from my browser that will invoke the sproc with atypical parameters. Lastly, I initiate a website request to a page that invokes the sproc with typical parameters, and observe that the request does not complete because of a SQL timeout on the sproc invocation. To resolve this on SQL Server 2005, I've added OPTIMIZE FOR hints to my SELECT. The sprocs that were vulnerable all have the "all-in-one" pattern described in this article. This pattern is certainly not ideal but was a necessary trade-off given the timeframe for the project.

    Read the article

  • Oracle Announces Oracle Exadata X3 Database In-Memory Machine

    - by jgelhaus
    Fourth Generation Exadata X3 Systems are Ideal for High-End OLTP, Large Data Warehouses, and Database Clouds; Eighth-Rack Configuration Offers New Low-Cost Entry Point ORACLE OPENWORLD, SAN FRANCISCO – October 1, 2012 News Facts During his opening keynote address at Oracle OpenWorld, Oracle CEO, Larry Ellison announced the Oracle Exadata X3 Database In-Memory Machine - the latest generation of its Oracle Exadata Database Machines. The Oracle Exadata X3 Database In-Memory Machine is a key component of the Oracle Cloud. Oracle Exadata X3-2 Database In-Memory Machine and Oracle Exadata X3-8 Database In-Memory Machine can store up to hundreds of Terabytes of compressed user data in Flash and RAM memory, virtually eliminating the performance overhead of reads and writes to slow disk drives, making Exadata X3 systems the ideal database platforms for the varied and unpredictable workloads of cloud computing. In order to realize the highest performance at the lowest cost, the Oracle Exadata X3 Database In-Memory Machine implements a mass memory hierarchy that automatically moves all active data into Flash and RAM memory, while keeping less active data on low-cost disks. With a new Eighth-Rack configuration, the Oracle Exadata X3-2 Database In-Memory Machine delivers a cost-effective entry point for smaller workloads, testing, development and disaster recovery systems, and is a fully redundant system that can be used with mission critical applications. Next-Generation Technologies Deliver Dramatic Performance Improvements Oracle Exadata X3 Database In-Memory Machines use a combination of scale-out servers and storage, InfiniBand networking, smart storage, PCI Flash, smart memory caching, and Hybrid Columnar Compression to deliver extreme performance and availability for all Oracle Database Workloads. Oracle Exadata X3 Database In-Memory Machine systems leverage next-generation technologies to deliver significant performance enhancements, including: Four times the Flash memory capacity of the previous generation; with up to 40 percent faster response times and 100 GB/second data scan rates. Combined with Exadata’s unique Hybrid Columnar Compression capabilities, hundreds of Terabytes of user data can now be managed entirely within Flash; 20 times more capacity for database writes through updated Exadata Smart Flash Cache software. The new Exadata Smart Flash Cache software also runs on previous generation Exadata systems, increasing their capacity for writes tenfold; 33 percent more database CPU cores in the Oracle Exadata X3-2 Database In-Memory Machine, using the latest 8-core Intel® Xeon E5-2600 series of processors; Expanded 10Gb Ethernet connectivity to the data center in the Oracle Exadata X3-2 provides 40 10Gb network ports per rack for connecting users and moving data; Up to 30 percent reduction in power and cooling. Configured for Your Business, Available Today Oracle Exadata X3-2 Database In-Memory Machine systems are available in a Full-Rack, Half-Rack, Quarter-Rack, and the new low-cost Eighth-Rack configuration to satisfy the widest range of applications. Oracle Exadata X3-8 Database In-Memory Machine systems are available in a Full-Rack configuration, and both X3 systems enable multi-rack configurations for virtually unlimited scalability. Oracle Exadata X3-2 and X3-8 Database In-Memory Machines are fully compatible with prior Exadata generations and existing systems can also be upgraded with Oracle Exadata X3-2 servers. Oracle Exadata X3 Database In-Memory Machine systems can be used immediately with any application certified with Oracle Database 11g R2 and Oracle Real Application Clusters, including SAP, Oracle Fusion Applications, Oracle’s PeopleSoft, Oracle’s Siebel CRM, the Oracle E-Business Suite, and thousands of other applications. Supporting Quotes “Forward-looking enterprises are moving towards Cloud Computing architectures,” said Andrew Mendelsohn, senior vice president, Oracle Database Server Technologies. “Oracle Exadata’s unique ability to run any database application on a fully scale-out architecture using a combination of massive memory for extreme performance and low-cost disk for high capacity delivers the ideal solution for Cloud-based database deployments today.” Supporting Resources Oracle Press Release Oracle Exadata Database Machine Oracle Exadata X3-2 Database In-Memory Machine Oracle Exadata X3-8 Database In-Memory Machine Oracle Database 11g Follow Oracle Database via Blog, Facebook and Twitter Oracle OpenWorld 2012 Oracle OpenWorld 2012 Keynotes Like Oracle OpenWorld on Facebook Follow Oracle OpenWorld on Twitter Oracle OpenWorld Blog Oracle OpenWorld on LinkedIn Mark Hurd's keynote with Andy Mendelsohn and Juan Loaiza - - watch for the replay to be available soon at http://www.youtube.com/user/Oracle or http://www.oracle.com/openworld/live/on-demand/index.html

    Read the article

  • Windows CE Chat Transcript (March 30, 2010)

    - by Bruce Eitman
    For those of you who missed the chat today, here is the raw transcript.   By raw, I mean that I copied and pasted the discussion without any edits. This is divided into two parts, the top part is the answers from the Microsoft Experts and the bottom part is the questions from the audience. Answers from Microsoft:   Karel Danihelka [MS] (Expert)[2010-3-30 12:2]: Hi everyone, my name is Karel Danihelka and I am developer in partner response team. Sing Wee [MS] (Expert)[2010-3-30 12:2]: Hi, I'm Sing Wee, part of the CoreOS/BSP Test Team. GLanger_MS (Expert)[2010-3-30 12:2]: Hi, I'm Glen Langer, program manager on the Core Team. Karel Danihelka [MS] (Expert)[2010-3-30 12:3]: Q: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals. Where should i start? A: Until you are using CPU with GHz frequency your only chance is use interrupt handler and implement all funcionality there. But it will be really tricky and may reduce system performance. If period will be near to millisecond timeframe you can use normal thread wait for event pattern. Karel Danihelka [MS] (Expert)[2010-3-30 12:5]: Q: I want to partition my NAND Flash device. One partition to use for hive ragistry and the other for the apps and data. The only way to do it is programmatically or setting some registry values ? A: It need to be set in registry - generally you need mark this partition as boot partition. Karel Danihelka [MS] (Expert)[2010-3-30 12:7]: Q: My CPU is Intel celeron M processor 1Ghz. A: In this case you can try use normal approach - in interrupt handler return SYSINTR and start thread in device driver which will spin thread waiting on event attached to this SYSINTR. Karel Danihelka [MS] (Expert)[2010-3-30 12:7]: Q: If i need to implement it using interrupt handlers, What are all the files that I should look at? A: Good quesiton - I would recommend documentation and there was BSP development book to download for free. mikehall_ms (Moderator)[2010-3-30 12:8]: Q: Hi guys, what's the formal way to report bugs back to the core team / product team? The mechanism of calling the support phone number every time is really onerous and time-consuming. Is there another mechanism? A: Using product support is the formal way to report bugs/issues - Product support can then create an issue that can be tracked. Karel Danihelka [MS] (Expert)[2010-3-30 12:9]: Q: But the operation for creating the partitions ? A: This is tricky - if you will make it autopartition & autoformat it will be created by filesystem. But generally it depends on your boot loader. mikehall_ms (Moderator)[2010-3-30 12:10]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? A: At MIX 2010 Charlie Kindel presented a session that described some of the core technologies that make up Windows Phone 7 Series, including the underlying operating system (Windows CE) and the new ISV programming model based on Silverlight and .NET - check out the Mix Online Videos to get more information. davbo-msft (Moderator)[2010-3-30 12:10]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? A: This forum is to discussed released products in the industry. Windows Mobile & Windows CE are based on the same Windows CE Kernel/system. Windows CE is focused on deliverying the OS for embedded customers in the market where Windows Mobile is focused on deliverying compelling Windows Phone platform. davbo-msft (Moderator)[2010-3-30 12:11]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? A: http://en.wikipedia.org/wiki/Windows_CE Wikipedia gives a good breakdown of the version history. Travis Hobrla [MS] (Expert)[2010-3-30 12:13]: Q: I created a OS design with KITL and kernel debugger enabled. But I am unable to connect to the target for debugging. I am getting the following error when i try to connect with the device. PB Debugger Cannot initialize the Kernel Debugger. PB Debugger Debugger could not initialize connection. PB Debugger The Kernel Debugger is waiting to connect with target. PB Debugger The Kernel Debugger has been disconnected successfully. A: One possibility is that a rogue cesvchost.exe has co-opted the debugger. I am assuming this is CE 6.0? Can you try exiting visual studio and manually killing the cesvchost.exe process from the Task Manager? davbo-msft (Moderator)[2010-3-30 12:14]: Q: Hi guys, what's the formal way to report bugs back to the core team / product team? The mechanism of calling the support phone number every time is really onerous and time-consuming. Is there another mechanism? A: For info on contacting Microsoft support refer to the support page on the Embedded website: http://msdn.microsoft.com/en-us/windowsembedded/dd897633.aspx Sing Wee [MS] (Expert)[2010-3-30 12:16]: Q: Do u mean ISR/IST implementation? How can i register an interrupt? What kind of interrupt should i register? A: A good introduction to interrupts in WinCE 6.0 can be found here (aside from the documentation on MSDN): http://download.microsoft.com/download/9/c/f/9cffaa58-4000-48d6-a4b2-5fed9e4e6410/Chapter%206%20-%20Developing%20Device%20Drivers.pdf mikehall_ms (Moderator)[2010-3-30 12:16]: Q: What will be different in Windows Compact 7 from CE 6.0? A: Unfortunately we cannot discuss unreleased products on this chat - keep an eye on the Windows Embedded web site and blogs to keep up to date with product announcements. Travis Hobrla [MS] (Expert)[2010-3-30 12:16]: Q: I am using CE 6.0. There is no cesvchost process running in my system. A: What operating system are you using? Karel Danihelka [MS] (Expert)[2010-3-30 12:16]: Q: So...I have to modify file system code to create 2 partition at system startup ?!! I haven't understood.... A: You don't need to modify code, there are registry settings to achive this (look to documentation). But you may need to create partition table in boot loader. Unfortunatelly there isn't simple way how to do it. davbo-msft (Moderator)[2010-3-30 12:18]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Windows Embedded CE 6.0 R3 includes Sliverlight for Windows Embedded. Refer to New Features overview on the embedded web site. http://www.microsoft.com/windowsembedded/en-us/products/windowsce/default.mspx. Silverlight - The power of Silverlight brought to Windows Embedded CE to create rich applications and user interfaces is new part of Windows CE Embedded. mikehall_ms (Moderator)[2010-3-30 12:20]: Q: The link for developing device drivers is not working. can u please check that? A: http://msdn.microsoft.com/en-us/library/ms923714.aspx davbo-msft (Moderator)[2010-3-30 12:20]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Sorry misunderstood the question I thought you were asking if embedded CE could handle Silverlight. Please repost so that the question goes back into the active queue because once answered no way to put the status back to open. Travis Hobrla [MS] (Expert)[2010-3-30 12:21]: Q: sorry! Windows XP SP3 A: Can you try exiting VS2005 and confirming cesvchost.exe is not running, then renaming C:\Documents and Settings\USERNAME\Local Settings\Application Data\Microsoft\CoreCon\1.0 to 1.0_backup, then restarting VS2005? Sing Wee [MS] (Expert)[2010-3-30 12:24]: Q: Can I have the book's name please? A: I believe the downloadable version is related to the last link I sent. If you go to the following website, I believe you can download the whole thing: http://msdn.microsoft.com/en-us/windowsembedded/ce/cc294468.aspx davbo-msft (Moderator)[2010-3-30 12:24]: Q: If one has an image on a Silverlight page, it seems to be cached. How would one refresh that cache after changing the underlying image? A: change the URI of the image or use a writeable bitmap if they want to manually toggle the pixels Sing Wee [MS] (Expert)[2010-3-30 12:25]: A: Whoops, hit [ENTER] too early. On the right side, you'll see there an "Exam Preparation Kit" link that can be downloaded in several different languages. Sing Wee [MS] (Expert)[2010-3-30 12:25]: Q: Can I have the book's name please? A: Whoops, hit [ENTER] too early. On the right side, you'll see there an "Exam Preparation Kit" link that can be downloaded in several different languages. Karel Danihelka [MS] (Expert)[2010-3-30 12:26]: Q: I have a NAND Flash on my target device. On this flash I have the hive registry and an application.I have observed that when the NAND flash is fully, the system startup time is longer....is there a degradation of NAND use that influences the startup time ? Why ? A: Yes - on boot flash abstraction library (old one) read metadata from all sectors to rebuild physical - logical mapping table. davbo-msft (Moderator)[2010-3-30 12:27]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Need addition info on this question. Can you provide more details on what you are trying to do in Silverlight? davbo-msft (Moderator)[2010-3-30 12:27]: Q: If one has an image on a Silverlight page, it seems to be cached. How would one refresh that cache after changing the underlying image? A: Additonal Info: if you want to manually touch the pixels use WriteableBitmap if you want to use the underlying HWND then use IXRVisualHost::GetHWND() davbo-msft (Moderator)[2010-3-30 12:28]: Q: Writable bitmap, is there an example of the syntax? A: if you want to manually touch the pixels use WriteableBitmap if you want to use the underlying HWND then use IXRVisualHost::GetHWND() davbo-msft (Moderator)[2010-3-30 12:29]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? A: Can I get more information about this question about what you are trying to accomplish in Silverlight? davbo-msft (Moderator)[2010-3-30 12:31]: Q: IXRVisualHost::GetHWND() exactly what I needed Thanks, A: Your welcome Sing Wee [MS] (Expert)[2010-3-30 12:31]: Q: ok. thanks for the book's link A: No problem. Travis Hobrla [MS] (Expert)[2010-3-30 12:32]: Q: Typically for SoC devices you name your hardware specific libraries in the form "SOCDIRNAME_LIBNAME". In our platform "OMAP35XX_TPS659XX_TI_V1" if you do this we cause the catalog parser to die... For example if we have a library "Musbfn_OMAP35XX_TPS659XX_TI_V1.dll" entering this in the catalogs pbcxml file in a <module> section causes the XML parser to fail with : Error 3 The 'urn:Microsoft.PlatformBuilder/Catalog:Module' element is        invalid - The value '012345678901234567890123456789.dll' is invalid         according to its datatype         'urn:Microsoft.PlatformBuilder/Catalog:CatalogFileName' - The actual         length is greater than the MaxLength value. A: There are a couple workarounds I can think of. I believe the Module element is only used when doing SYSGEN parsing to make sure dependent SYSGENs are present when the item is selected, so I believe it is optional to the catalog. The other obvious workaround is to shorten the soc name. I realize neither of these solutions is ideal. This is not something we anticipated when we tested CE6.0, sorry. Travis Hobrla [MS] (Expert)[2010-3-30 12:33]: Q: I am getting this error only when I select the KdStub as the debugger in Target device connectivity. A: Right, but KdStub is the debugger that you should use. Have you tried the steps I suggested? Travis Hobrla [MS] (Expert)[2010-3-30 12:36]: Q: If I select Active KTIL, My OS doesn't boots. It says "loading NK.EXE at 0x<xxxxx> location" after that nothing comes in the debug log. A: Can you look at the serial debug output and see what is happening there? Often it can give you a clue to the KITL driver malfunctioning. Travis Hobrla [MS] (Expert)[2010-3-30 12:38]: Q: I have tried that and I am getting the same error. A: I am assuming you have a device created in Target -> Connectivity Options in Platform Builder. What are the Kernel download / Kernel transport for your device? Travis Hobrla [MS] (Expert)[2010-3-30 12:40]: Q: KITL: *** Device Name CEPC56059 *** WARN: KITL will run in polling mode VBridge:: built on [Jul 10 2009] time [10:20:14] VBridgeInit()...TX = [16384] bytes -- Rx = [16384] bytes Tx buffer [0xA1B84860] to [0xA1B88860]. Rx buffer [0xA1B88880] to [0xA1B8C880]. VBridge:: NK add MAC: [0-60-65-2-DA-FB] Connecting to Desktop KITL: Connected host IP: 1 Port: 1086 .. this is the output of the serial debug A: This looks reasonable and does not give clues as to why boot would halt at that point. If you capture a network trace or turn on KITL debug zones via dpCurSettings in kitl.dll, do you see KITL active after this? Travis Hobrla [MS] (Expert)[2010-3-30 12:41]: Q: Both is happening via Ethernet. A: Only thing I have left to suggest is a Platform Builder installation Repair, then. Karel Danihelka [MS] (Expert)[2010-3-30 12:42]: Q: Hi, I saw that the ATADISK is quite generic and des not have any optimizations. Do you have any advice to consider while tryin to improve the performance of it? A: If I remember correctly sample code has support for some specific hardware controllers (little obsolete now). This should be good start point (if you will not decide take existing driver as sample and write you own). Travis Hobrla [MS] (Expert)[2010-3-30 12:44]: Q: I didn't do that. I have to try. A: I think that's the next valid step. You need to figure out whether KITL is hanging or the device - use instrumented serial debug messages and network trace to determine this. Sing Wee [MS] (Expert)[2010-3-30 12:46]: Q: KITL: *** Device Name CEPC56059 *** WARN: KITL will run in polling mode VBridge:: built on [Jul 10 2009] time [10:20:14] VBridgeInit()...TX = [16384] bytes -- Rx = [16384] bytes Tx buffer [0xA1B84860] to [0xA1B88860]. Rx buffer [0xA1B88880] to [0xA1B8C880]. VBridge:: NK add MAC: [0-60-65-2-DA-FB] Connecting to Desktop KITL: Connected host IP: 1 Port: 1086 .. this is the output of the serial debug A: Neo, have you by any chance tried looking into your firewall to see if it might be blocking traffic on any particular ports? Wireshark/netmon might be able to help you here if that's the issue. davbo-msft (Moderator)[2010-3-30 12:48]: Q: I lost spell check, how can i get it back A: Hello - can you give additional details about your question? Is this related to a Windows CE Embedded application? masatos_MSFT (Expert)[2010-3-30 12:51]: Q: When attempting to run the CETK cellcore tests the documentation states the pre-requisites include "stinger.ini", "ltk.ini" but windows CE doesn't provide these or document what they fully need to contain. Implicitly you also need "datatrans.xml" which isn't supplied. If you get around this error and steal these from Windows Mobile instead, when you try and run the CETK tests you get a data abort in radiometricsdll.dll. How should we invoke the cellcore parts of CETK? A: Hi Pev, what version of Windows CE and CETK are you using? I do not have the expertise to answer this question, but can find somebody who can. Travis Hobrla [MS] (Expert)[2010-3-30 12:52]: Q: I don't see a kitlcore.dll in my OS. is my debug image fails to load because of that? A: kitl.dll should be all that's needed, kitlcore.lib is linked into that. Travis Hobrla [MS] (Expert)[2010-3-30 12:55]: Q: I've got a platform (not developed by myself) where I2C bus support has to be provided through the OAL as the kernel needs to talk to devices such as the power management IC and gas gauge so a 'proper' I2C driver hanging off device manager isn't possible. This happens to be a polled driver, so obviously it hits the system hard when either under lots of traffic or an error condition occurs and the driver constantly polls. I originally thought that there was no straightforward way to make such code interrupt driven in the kernel (as it's a cludge) but I realised that that's exactly what ETHDBG drivers do. Is there any reason why I shouldn't have a go at implementing a similar mechanism for our kernel resident I2C driver? If not, are there any obvious pitfalls - I've not seen any other BSP's do this in the past... A: You can make a 'proper' driver that calls down into the OAL to do the actual I2C transactions. Alternatively you can build an interrupt-based version in the OAL where you handle everything in the ISR. There is nothing wrong with that so long as the rest of your drivers and app threads can handle longer times with interrupts off while you are servicing I2C interrupts. Sing Wee [MS] (Expert)[2010-3-30 12:55]: Q: I am having trouble with my mouse, I have the microsoft wireless mobile mouse 3000, when I push the scroll button I am suppose to have autoscroll instead it shows other web pages,Can you help me out tell me what to do!!! A: Sorry, this current chat is about Windows Embedded Compact. Hope you're able to find an answer to your question elsewhere. davbo-msft (Moderator)[2010-3-30 12:56]: Q: Is the Silverlight Animation "Spline" a BezierSpline? A: Spline - http://msdn.microsoft.com/en-us/library/ee501495.aspx<BR< a>>   masatos_MSFT (Expert)[2010-3-30 12:57]: Thanks for the info Pev. I will follow up with the CETK experts here and get back to you. davbo-msft (Moderator)[2010-3-30 12:59]: Q: Spline- bad link A: http://msdn.microsoft.com/en-us/library/ee501495.aspx davbo-msft (Moderator)[2010-3-30 13:0]: Q: Sorry, got to tirm the ">" A: No Worries http://msdn.microsoft.com/en-us/library/ee501495.aspx davbo-msft (Moderator)[2010-3-30 13:0]: Hello everyone, we are just about out of time. Thank you for joining us for our Windows Embedded CE 6.0 chat today! <http://www.Microsoft.com/Embedded>; A special thank you to the product group members for coming out. The transcript of today’s chat will be posted online as soon as possible, to <http://msdn.microsoft.com/en-us/chats>;. We’ll see you again for another chat next month. Please check <http://msdn.microsoft.com/en-us/chats>; for the list of upcoming chats. If you still have unanswered questions, let me suggest that you post them on one of our newsgroups on <http://msdn.microsoft.com/en-us/windowsembedded/ce/default.aspx> -Windows Embedded CE 6.0 R3 Now Available! <http://msdn.microsoft.com/windowsembedded/ce/dd630616.aspx>; davbo-msft (Moderator)[2010-3-30 13:1]: Q: hi everybody. I would like to know if there is something know about a bug in RTC API (VOIP), especially when using SIP. According the to the analysis with application verifyier there is a heap link in rtcdllmedia.dll. All of the unreleased chunks seem to have a size of 6560 bytes. A: I will follow up with the Networking Team for a response. davbo-msft (Moderator)[2010-3-30 13:1]: Q: Hi, we've problems with debugging of applications (= breakpoints in Platform Builder will be ignored) over KITL on Windows CE 5.0, if the PDB files are large (over 60MB). Are there any limitations to size of the PDB files? A: I will follow up with the tools team for a response and post with the transcript. Sing Wee [MS] (Expert)[2010-3-30 13:1]: Q: I am unable to use the target control in my development environment. any ideas? A: Make sure you have SYSGEN_SHELL=1 set in your build environment. davbo-msft (Moderator)[2010-3-30 13:3]: Q: what are the main differences between Object Store and RAM disk ? They are both in RAM...are there performance differences ? access differences ? A: I will follow up with the Core Team and get a response posted with the transcript to MSDN  The Questions   [2010-3-30 12:57]: Thanks for the info Pev. I will follow up with the CETK experts here and get back to you. [2010-3-30 12:59]:   [2010-3-30 13:0]:   [2010-3-30 13:0]: Hello everyone, we are just about out of time. Thank you for joining us for our Windows Embedded CE 6.0 chat today! <http://www.Microsoft.com/Embedded>; A special thank you to the product group members for coming out. The transcript of today’s chat will be posted online as soon as possible, to <http://msdn.microsoft.com/en-us/chats>;. We’ll see you again for another chat next month. Please check <http://msdn.microsoft.com/en-us/chats>; for the list of upcoming chats. If you still have unanswered questions, let me suggest that you post them on one of our newsgroups on <http://msdn.microsoft.com/en-us/windowsembedded/ce/default.aspx> -Windows Embedded CE 6.0 R3 Now Available! <http://msdn.microsoft.com/windowsembedded/ce/dd630616.aspx>; [2010-3-30 13:1]: [2010-3-30 13:1]: [2010-3-30 13:1]: [2010-3-30 13:3]: neo (Guest)[2010-3-30 11:37]: Hi all KellyG (Guest)[2010-3-30 11:37]: Hi KellyG (Guest)[2010-3-30 11:37]: I have a question unrelated to windows Ce embedded, can you please help me?? neo (Guest)[2010-3-30 11:38]: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals! c neo (Guest)[2010-3-30 11:38]: yes. post it. May be i cud give a try KellyG (Guest)[2010-3-30 11:38]: My Product key listed on my tower is not the product key I need for microsoft office, but that is the only product key listed. neo (Guest)[2010-3-30 11:39]: I hope this is a chat for windows embedded. please post ur queries in office forums KellyG (Guest)[2010-3-30 11:39]: it is but i could not find a forum for office neo (Guest)[2010-3-30 11:40]: I think moderators will help u out. @ davbo-msft: can u help this guy? neo (Guest)[2010-3-30 11:41]: Q: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals. Where should i start? davbo-msft (Moderator)[2010-3-30 11:50]: Our chat today covers the topic of Windows Embedded CE! 1. This chat will last for one hour. During this hour, our Experts will respond to as many questions as they can. Please understand that there may be some questions we cannot respond to due to lack of information or because the information is not yet public. 2. We encourage you to submit questions for our Experts. To do so, type your questions in the send box, select the “ask the Experts” box and click SEND. Questions sent directly to the Guest Chat room will not be answered by the Experts, but we encourage other community members to assist. 3. We ask that you stay on topic for the duration of the chat. This helps the Guests and Experts follow the conversation more easily. We invite you to ask off topic questions after this chat is over, but not during. 4. Please abide by the Chat Code of Conduct. Chat code of conduct: <http://msdn.microsoft.com/chats/chatroom.aspx?ctl=hlp#Conduct>; Pev (Guest)[2010-3-30 11:54]: Evening! davbo-msft (Moderator)[2010-3-30 11:54]: Hello everyone this is Dave Boyce - I worked in the Multimedia area for Windows CE. neo (Guest)[2010-3-30 11:55]: hello dave neo (Guest)[2010-3-30 11:55]: The chat code of conduct link is not working! Pev (Guest)[2010-3-30 11:56]: Best be polite just in case then ;-) neo (Guest)[2010-3-30 11:56]: davbo-msft (Moderator)[2010-3-30 11:57]: I'll check out the issue w/ the link paolopat (Guest)[2010-3-30 12:0]: Hello davbo-msft (Moderator)[2010-3-30 12:0]: We are pleased to welcome our Experts for today’s chat. I will have them introduce themselves now. Chat will begin in a couple of minutes. <http://www.Microsoft.com/Embedded>; paolopat (Guest)[2010-3-30 12:3]: Hello Experts ! neo (Guest)[2010-3-30 12:3]: Welcome all! paolopat (Guest)[2010-3-30 12:3]: Q: I want to partition my NAND Flash device. One partition to use for hive ragistry and the other for the apps and data. The only way to do it is programmatically or setting some registry values ? neo (Guest)[2010-3-30 12:3]: Q: I need to implement hardware timers on my windows CE 6.0 device to trigger events at microsecond intervals. Where should i start? neo (Guest)[2010-3-30 12:5]: Q: My CPU is Intel celeron M processor 1Ghz. Pev (Guest)[2010-3-30 12:5]: neo: if your silicon has multiple general purpose timers, pick one that's not in use for the system timer / profiler and set it up to trigger irqs for your purpose. You can't guarantee hard realtime type responses though... GarySwalling (Guest)[2010-3-30 12:5]: Q: Is Windows Phone 7 related to Windows CE? If so, can you tell me what version of Windows CE is the basis? Is it in fact the new version of Windows Mobile? Pev (Guest)[2010-3-30 12:6]: Q: Hi guys, what's the formal way to report bugs back to the core team / product team? The mechanism of calling the support phone number every time is really onerous and time-consuming. Is there another mechanism? paolopat (Guest)[2010-3-30 12:6]: Q: But the operation for creating the partitions ? neo (Guest)[2010-3-30 12:6]: Q: If i need to implement it using interrupt handlers, What are all the files that I should look at? GPM (Guest)[2010-3-30 12:6]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? Jhony (Guest)[2010-3-30 12:7]: Q: I created a OS design with KITL and kernel debugger enabled. But I am unable to connect to the target for debugging. I am getting the following error when i try to connect with the device. PB Debugger Cannot initialize the Kernel Debugger. PB Debugger Debugger could not initialize connection. PB Debugger The Kernel Debugger is waiting to connect with target. PB Debugger The Kernel Debugger has been disconnected successfully. Charles (Guest)[2010-3-30 12:7]: What will be different in Windows Compact 7 from CE 6.0? neo (Guest)[2010-3-30 12:8]: Can I have the book's name please? kiefs_dev (Guest)[2010-3-30 12:8]: Q: hi everybody. I would like to know if there is something know about a bug in RTC API (VOIP), especially when using SIP. According the to the analysis with application verifyier there is a heap link in rtcdllmedia.dll. All of the unreleased chunks seem to have a size of 6560 bytes. paolopat (Guest)[2010-3-30 12:10]: Q: So...I have to modify file system code to create 2 partition at system startup ?!! I haven't understood.... neo (Guest)[2010-3-30 12:10]: Q: Do u mean ISR/IST implementation? How can i register an interrupt? What kind of interrupt should i register? neo (Guest)[2010-3-30 12:11]: Q: Can I have the book's name please? Charles (Guest)[2010-3-30 12:11]: Q: What will be different in Windows Compact 7 from CE 6.0? PaulT (Guest)[2010-3-30 12:11]: neo: I'd say that you really need the docs for YOUR BSP, not generic documents for BSPs in general. Each BSP may be architected differently. If you're using the CEPC BSP, then the documentation that comes with Platform Builder is a reasonable place to look. GPM (Guest)[2010-3-30 12:11]: Q: If one has an image on a Silverlight page, it seems to be cached. How would one refresh that cache after changing the underlying image? Elektrobit (Guest)[2010-3-30 12:12]: Q: Hi, we've problems with debugging of applications (= breakpoints in Platform Builder will be ignored) over KITL on Windows CE 5.0, if the PDB files are large (over 60MB). Are there any limitations to size of the PDB files? Jhony (Guest)[2010-3-30 12:15]: Q: I am using CE 6.0. There is no cesvchost process running in my system. alexquisi (Guest)[2010-3-30 12:15]: Q: Hi, I saw that the ATADISK is quite generic and des not have any optimizations. Do you have any advice to consider while tryin to improve the performance of it? Jhony (Guest)[2010-3-30 12:17]: Windows XP service pack 1 Jhony (Guest)[2010-3-30 12:17]: Q: sorry! Windows XP SP3 neo (Guest)[2010-3-30 12:19]: Q: The link for developing device drivers is not working. can u please check that? paolopat (Guest)[2010-3-30 12:20]: Q: I have a NAND Flash on my target device. On this flash I have the hive registry and an application.I have observed that when the NAND flash is fully, the system startup time is longer....is there a degradation of NAND use that influences the startup time ? Why ? Pev (Guest)[2010-3-30 12:20]: Q: When attempting to run the CETK cellcore tests the documentation states the pre-requisites include "stinger.ini", "ltk.ini" but windows CE doesn't provide these or document what they fully need to contain. Implicitly you also need "datatrans.xml" which isn't supplied. If you get around this error and steal these from Windows Mobile instead, when you try and run the CETK tests you get a data abort in radiometricsdll.dll. How should we invoke the cellcore parts of CETK? Pev (Guest)[2010-3-30 12:21]: Hi all, Pev (Guest)[2010-3-30 12:21]: oops Pev (Guest)[2010-3-30 12:21]: :-D Pev (Guest)[2010-3-30 12:24]: Typically for SoC devices you name your hardware specific libraries in the form "SOCDIRNAME_LIBNAME". In our platform "OMAP35XX_TPS659XX_TI_V1" if you do this we cause the catalog parser to die... For example if we have a library "Musbfn_OMAP35XX_TPS659XX_TI_V1.dll" entering this in the catalogs pbcxml file in a <module> section causes the XML parser to fail with : Pev (Guest)[2010-3-30 12:25]: Q: Error 3 The 'urn:Microsoft.PlatformBuilder/Catalog:Module' element is        invalid - The value '012345678901234567890123456789.dll' is invalid         according to its datatype         'urn:Microsoft.PlatformBuilder/Catalog:CatalogFileName' - The actual         length is greater than the MaxLength value. GPM (Guest)[2010-3-30 12:25]: Q: Writable bitmap, is there an example of the syntax? Pev (Guest)[2010-3-30 12:25]: Q: Typically for SoC devices you name your hardware specific libraries in the form "SOCDIRNAME_LIBNAME". In our platform "OMAP35XX_TPS659XX_TI_V1" if you do this we cause the catalog parser to die... For example if we have a library "Musbfn_OMAP35XX_TPS659XX_TI_V1.dll" entering this in the catalogs pbcxml file in a <module> section causes the XML parser to fail with : Error 3 The 'urn:Microsoft.PlatformBuilder/Catalog:Module' element is        invalid - The value '012345678901234567890123456789.dll' is invalid         according to its datatype         'urn:Microsoft.PlatformBuilder/Catalog:CatalogFileName' - The actual         length is greater than the MaxLength value. Pev (Guest)[2010-3-30 12:25]: sorry, messed up submission there! GPM (Guest)[2010-3-30 12:26]: Q: I would like to get a handle to a Silverlight screen section, is that possiable? GPM (Guest)[2010-3-30 12:28]: Q: IXRVisualHost::GetHWND() exactly what I needed Thanks, PaulT (Guest)[2010-3-30 12:29]: GPM: You don't have to keep submitting the questions. The chat experts have an application that they're using to follow the chat and all Ask the Experts questions are logged. Jhony (Guest)[2010-3-30 12:29]: Q: I am getting this error only when I select the KdStub as the debugger in Target device connectivity. neo (Guest)[2010-3-30 12:30]: Q: ok. thanks for the book's link Pev (Guest)[2010-3-30 12:31]: Hm, did those two I submitted get picked up by anyone? neo (Guest)[2010-3-30 12:33]: Q: If I select Active KTIL, My OS doesn't boots. It says "loading NK.EXE at 0x<xxxxx> location" after that nothing comes in the debug log. PaulT (Guest)[2010-3-30 12:34]: Pev: PaulT (Guest)[2010-3-30 12:35]: Pev: I'm sure they did. The guys who are actually on the chat may not be experts in that part of things. That's usually the explanation when you don't get an answer in 10 minutes or so. Pev (Guest)[2010-3-30 12:36]: Ah, fair enough Susie (Guest)[2010-3-30 12:36]: My Outlook Express incoming mail is corrput. No ONE has been able to fix the problem, Dell or Norton. I have dial up I'm in a rural area Jhony (Guest)[2010-3-30 12:37]: Q: I have tried that and I am getting the same error. Pev (Guest)[2010-3-30 12:37]: Susie : Use Thunderbird instead :-D PaulT (Guest)[2010-3-30 12:37]: Susie: Sorry, but this chat is not about Windows, but Embedded (like what runs on a phone). Your best chance is to find a local expert or talk to your ISP. paolopat (Guest)[2010-3-30 12:37]: Q: what are the main differences between Object Store and RAM disk ? They are both in RAM...are there performance differences ? access differences ? Susie (Guest)[2010-3-30 12:38]: My computer knowlege is very limited, what is Thunderbird? Pev (Guest)[2010-3-30 12:38]: A different email client :-D neo (Guest)[2010-3-30 12:39]: Q: KITL: *** Device Name CEPC56059 *** WARN: KITL will run in polling mode VBridge:: built on [Jul 10 2009] time [10:20:14] VBridgeInit()...TX = [16384] bytes -- Rx = [16384] bytes Tx buffer [0xA1B84860] to [0xA1B88860]. Rx buffer [0xA1B88880] to [0xA1B8C880]. VBridge:: NK add MAC: [0-60-65-2-DA-FB] Connecting to Desktop KITL: Connected host IP: 1 Port: 1086 .. this is the output of the serial debug Susie (Guest)[2010-3-30 12:39]: Do I need to uninstall Outlook Express youngboyzie (Guest)[2010-3-30 12:39]: I need to start battery calibration for my new battery for my dell inspiron 1525 laptop and should be able to reach the BIOS screen by hitting f2 but this isnt working... help? Pev (Guest)[2010-3-30 12:39]: Nah, you can run it instead - you'll still need help from your ISP to configure it I expect Jhony (Guest)[2010-3-30 12:39]: Q: Both is happening via Ethernet. PaulT (Guest)[2010-3-30 12:40]: youngboyzie: You're off-topic. This is not a general chat for Windows and certainly not for Dell. You'll have to ask Dell how to get to setup; it's their machine. bill (Guest)[2010-3-30 12:41]: I lost spell check, how can i get et back neo (Guest)[2010-3-30 12:42]: Q: I didn't do that. I have to try. Jhony (Guest)[2010-3-30 12:43]: Q: Ok. I will do it then. bill (Guest)[2010-3-30 12:43]: Q: I lost spell check, how can i get it back PaulT (Guest)[2010-3-30 12:44]: bill: This isn't a general Windows chat. There are some Web forums that you might try. GarySwalling (Guest)[2010-3-30 12:45]: Q: Thanks, I found the Phone 7 presentation at http://live.visitmix.com/MIX10/Sessions/CL13 GPM (Guest)[2010-3-30 12:45]: Q: Is the Silverlight Animation "Spline" a BezierSpline? neo (Guest)[2010-3-30 12:46]: Q: ok. I'll do it. thanks Pev (Guest)[2010-3-30 12:46]: Whowever was asking about KITL connection : I've had this loads in the past. I think I started debugging last time by using wireshark to see what was happening on the network then setting up the OAL_ETHER and OAL_FUNC and OAL_VERBOSE as well as OAL_KITL flags to see what was actually happening in the driver.... Pev (Guest)[2010-3-30 12:47]: I'd generally make sure that you're testing though a 10baseT hub (instead of anything faster) and forcing Active KITL in polled mode too... neo (Guest)[2010-3-30 12:48]: Q: I disabled the firewall in my PC. Pev (Guest)[2010-3-30 12:50]: Q: I've got a platform (not developed by myself) where I2C bus support has to be provided through the OAL as the kernel needs to talk to devices such as the power management IC and gas gauge so a 'proper' I2C driver hanging off device manager isn't possible. This happens to be a polled driver, so obviously it hits the system hard when either under lots of traffic or an error condition occurs and the driver constantly polls. I originally thought that there was no straightforward way to make such code interrupt driven in the kernel (as it's a cludge) but I realised that that's exactly what ETHDBG drivers do. Is there any reason why I shouldn't have a go at implementing a similar mechanism for our kernel resident I2C driver? If not, are there any obvious pitfalls - I've not seen any other BSP's do this in the past... neo (Guest)[2010-3-30 12:51]: Q: I don't see a kitlcore.dll in my OS. is my debug image fails to load because of that? Pev (Guest)[2010-3-30 12:52]: Q: Hi masatos, I'm using Windows Embedded CE 6.0 with R3 and patched to feb 2010's QFE's (with it's associated CETK version) this is a machine with only CE 6.0 on (no conflicts with earlier CE or WM...) neo (Guest)[2010-3-30 12:54]: ok. Got it neo (Guest)[2010-3-30 12:54]: Q: ok. Got it Roundman (Guest)[2010-3-30 12:55]: Q: I am having trouble with my mouse, I have the microsoft wireless mobile mouse 3000, when I push the scroll button I am suppose to have autoscroll instead it shows other web pages,Can you help me out tell me what to do!!! Pev (Guest)[2010-3-30 12:55]: Hey neo, debugging kitl issues is really frustrating but dont lose heart :-) neo (Guest)[2010-3-30 12:55]: @ pev : u fixed the problem of KITL after that? neo (Guest)[2010-3-30 12:56]: I am getting the same error again and again. I even cleaned my environment and tried in a fresh PC. But didn't succeed yet Pev (Guest)[2010-3-30 12:56]: Well, eventually - my experiences probably won't help you as different platforms have different reasons for doing that neo (Guest)[2010-3-30 12:56]: I think so PaulT (Guest)[2010-3-30 12:58]: neo: Have you searched the old messages in microsoft.public.windowsce.platbuilder? It seems to me that there was a packet size situation where it was possible to have problems with KITL connections based on a setting on the PC. Google Groups, groups.google.com, Advanced Groups Search will allow you to search a single newsgroup or a set of newsgroups easily. GPM (Guest)[2010-3-30 12:58]: Q: Spline- bad link PaulT (Guest)[2010-3-30 12:58]: GPM: without the > at the end does it work? It seems to for me... neo (Guest)[2010-3-30 12:58]: But some times if i try to connect to the device again. The Image information is seen in the serial debug. what does that mean?Download BIN file information: ----------------------------------------------------- [0]: Base Address=0x220000 Length=0x18DAADC Received a broadcast message !CheckUDP: Not UDP (proto = 0x00000001) after this i am getting the old errors. PB debugger cannot initialize ... GPM (Guest)[2010-3-30 12:59]: Q: Sorry, got to tirm the ">" neo (Guest)[2010-3-30 12:59]: ok paul. I ll look into that. davbo-msft (Moderator)[2010-3-30 13:0]: Hello everyone, we are just about out of time. Thank you for joining us for our Windows Embedded CE 6.0 chat today! <http://www.Microsoft.com/Embedded>; A special thank you to the product group members for coming out. The transcript of today’s chat will be posted online as soon as possible, to <http://msdn.microsoft.com/en-us/chats>;. We’ll see you again for another chat next month. Please check <http://msdn.microsoft.com/en-us/chats>; for the list of upcoming chats. If you still have unanswered questions, let me suggest that you post them on one of our newsgroups on <http://msdn.microsoft.com/en-us/windowsembedded/ce/default.aspx> -Windows Embedded CE 6.0 R3 Now Available! <http://msdn.microsoft.com/windowsembedded/ce/dd630616.aspx>; neo (Guest)[2010-3-30 13:1]: Q: I am unable to use the target control in my development environment. any ideas? Pev (Guest)[2010-3-30 13:1]: Sure, if KITL isn't connected target control won't work as it runs over kitl... neo (Guest)[2010-3-30 13:1]: ok .thanks pev neo (Guest)[2010-3-30 13:2]: yes. sysgen_shell is set to 1 neo (Guest)[2010-3-30 13:2]: Q: yes. sysgen_shell is set to 1 Marcelovk (Guest)[2010-3-30 13:2]: Q: Is there any way to extract the default command lines of the tests in CETK? I want to have it running unconnected from the desktop.   Copyright © 2010 – Bruce Eitman All Rights Reserved

    Read the article

  • No more internet connection after update in 14.04 with Intel Dual Band Wireless AC 7260

    - by luis
    My Dell XPS 15 (haswell) was working fine until I stupidly accepted recently to apply Ubuntu updates. Since then, my wifi does not work (it shows "device not managed" when clicking wifi icon in toolbar). Even USB to Ethernet adapter does not seem to work. Bluetooth at least "sees" other bluetooth devices around... See below output from dmesg (dmesg |grep iwl) : [ 886.462459] iwlwifi 0000:06:00.0: irq 51 for MSI/MSI-X [ 886.462561] iwlwifi 0000:06:00.0: Direct firmware load failed with error -2 [ 886.462562] iwlwifi 0000:06:00.0: Falling back to user helper [ 886.463284] iwlwifi 0000:06:00.0: loaded firmware version 22.1.7.0 op_mode iwlmvm [ 886.475345] iwlwifi 0000:06:00.0: Detected Intel(R) Dual Band Wireless AC 7260, REV=0x144 [ 886.475433] iwlwifi 0000:06:00.0: L1 Enabled; Disabling L0S [ 886.475684] iwlwifi 0000:06:00.0: L1 Enabled; Disabling L0S [ 886.689214] ieee80211 phy0: Selected rate control algorithm 'iwl-mvm-rs' Below the output from modinfo iwlwifi: filename: /lib/modules/3.13.0-29- generic/kernel/drivers/net/wireless/iwlwifi/iwlwifi.ko license: GPL author: Copyright(c) 2003-2013 Intel Corporation <[email protected]> version: in-tree: description: Intel(R) Wireless WiFi driver for Linux firmware: iwlwifi-100-5.ucode firmware: iwlwifi-1000-5.ucode firmware: iwlwifi-135-6.ucode firmware: iwlwifi-105-6.ucode firmware: iwlwifi-2030-6.ucode firmware: iwlwifi-2000-6.ucode firmware: iwlwifi-5150-2.ucode firmware: iwlwifi-5000-5.ucode firmware: iwlwifi-6000g2b-6.ucode firmware: iwlwifi-6000g2a-5.ucode firmware: iwlwifi-6050-5.ucode firmware: iwlwifi-6000-4.ucode firmware: iwlwifi-3160-7.ucode firmware: iwlwifi-7260-7.ucode srcversion: 1E6912E109D5A43B310FB34 alias: pci:v00008086d0000095Asv*sd00005490bc*sc*i* (a pack of lines of kind "alias: pci:xxxxx...." that I guess are not helpful) alias: pci:v00008086d0000095Bsv*sd00005290bc*sc*i* depends: cfg80211 intree: Y vermagic: 3.13.0-29-generic SMP mod_unload modversions signer: Magrathea: Glacier signing key sig_key: 66:02:CB:36:F1:31:3B:EA:01:C4:BD:A9:65:67:CF:A7:23:C9:70:D8 sig_hashalgo: sha512 parm: swcrypto:using crypto in software (default 0 [hardware]) (int) parm: 11n_disable:disable 11n functionality, bitmap: 1: full, 2: disable agg TX, 4: disable agg RX, 8 enable agg TX (uint) parm: amsdu_size_8K:enable 8K amsdu size (default 0) (int) parm: fw_restart:restart firmware in case of error (default true) (bool) parm: antenna_coupling:specify antenna coupling in dB (defualt: 0 dB) (int) parm: wd_disable:Disable stuck queue watchdog timer 0=system default, 1=disable, 2=enable (default: 0) (int) parm: nvm_file:NVM file name (charp) parm: bt_coex_active:enable wifi/bt co-exist (default: enable) (bool) parm: led_mode:0=system default, 1=On(RF On)/Off(RF Off), 2=blinking, 3=Off (default: 0) (int) parm: power_save:enable WiFi power management (default: disable) (bool) parm: power_level:default power save level (range from 1 - 5, default: 1) (int) I downloaded the latest versions of iwlwifi firmware from git (git clone git://git.kernel.org/pub/scm/linux/kernel/git/firmware/linux-firmware.git; copy iwlwifi-3160-9.ucode iwlwifi-7260-9.ucode iwlwifi-7265-9.ucode to /lib/firmware and reboot) but as you can imagine it did not help. Update #1: Downloaded from http://wireless.kernel.org/en/users/Drivers/iwlwifi?action=AttachFile&do=get&target=iwlwifi-7260-ucode-22.15.8.0.tgz and copied the file into /lib/firmware. After reloading it with modprobe, it seems to be OK: [ 14.761283] iwlwifi 0000:06:00.0: enabling device (0000 -> 0002) [ 14.761472] iwlwifi 0000:06:00.0: irq 51 for MSI/MSI-X [ 14.772478] iwlwifi 0000:06:00.0: loaded firmware version 22.15.8.0 op_mode iwlmvm [ 14.800274] iwlwifi 0000:06:00.0: Detected Intel(R) Dual Band Wireless AC 7260, REV=0x144 [ 14.800349] iwlwifi 0000:06:00.0: L1 Enabled; Disabling L0S [ 14.800657] iwlwifi 0000:06:00.0: L1 Enabled; Disabling L0S [ 15.007048] ieee80211 phy0: Selected rate control algorithm 'iwl-mvm-rs' However, clicking in wifi in the toolbar still shows "device not managed". Any clues? Many thanks! Luis

    Read the article

  • Install Problem (Ubuntu Server 10.04) with USB as it reboots when I hit 'enter' for 'Install Ubuntu Server' option! Help

    - by Alastair
    We cannot seem to install Ubuntu Server with USB as it reboots when I hit 'enter' for 'Install Ubuntu Server' option. My friend wants to try setting up a server so; we downloaded Ubuntu Server 10.04.4 we created a boot CD and installed ubuntu server no problem at all. But then the problem arose the hardrive we wanted to use is a 1tb sata drive and the computer orginally has 40gb IDE. So I bought a Sata to IDE and IDE to Sata converter from: http://www.microdirect.co.uk/Home/Product/52926/IDE-to-SATA-converter---Converts-IDE-HDD-to-SATA-inc-sata-data-and-power-cables Unfortunately this converter means I cannot plug in the IDE cable meaning I only have one IDE connection i.e CD drive has to be disconnected for the 1tb sata Hardrive to be connected. So now the 1tb drive is connected, powered it on opened the bios to make sure the hdd appeared it did as ST3ASDAPFKG (somthing like that). Fortunately the computer supports USB booting, so I read ubuntu server usb install instructions I tried: Startup Disk Creator & Unebootin Startup Disk Creator made the usb bootable with the 'ubuntu-10.04.4-server-i386.iso' All looked fine stuck the usb drive in, booted the machine up and I am quickly presented with ubuntu language choice. I hit enter to select English then I am presented with: Install Ubuntu Server, Install Ubuntu Enterprise Cloud, Check Disk for defects, test memory, Boot from first hard disk, Rescue a broken system I can move up and down the menu fine everything seems ok, I select 'Install Ubuntu Server', computer just hangs and screen either goes blank or locks. So I rebooted the computer loads the same menus fine, I select 'Install Ubuntu Server' hit 'enter' and the computer just restarts then brings me back to the same menu. hmmm Then I tried choosing the rest of the options separately: Install Ubuntu Server, Install Ubuntu Enterprise Cloud, Check Disk for defects, test memory, Boot from first hard disk, Rescue a broken system computer just restarts and back to the same ubuntu menu every-time. Grrrr At this point I wish I actually new how to command line install or something but I don't have a clue how to do that. So I tried hitting 'f6' for 'other options' and I tried them all in various combinations and individually. No Luck: (Expert mode, acpi=off, noapic, nolapic, edd=on, nodmraid, nomodeset, Free Software only) At this point I am wondering if it is a bios setting causing problems, I tried turning every option in there on off that I don't understand. No Luck. I then discovered by accident if you hit esc in the ubuntu install menu it says "you are leaving the graphical boot menu and starting the text mode interface" I hit 'Ok'. Next a prompt pops up saying 'boot:' One time it responded when I typed somthing with 'Cannot find kernal image (something like that but since then it just restarts when I hit enter in that prompt). I had a browse on the net and found someone suggesting removing quiet from install command for 'Install Ubuntu Server'. Made no difference at all just reboots... Orginal boot options noprompt cdrom-detect/try-usb=true persistent file=/cdrom/preseed/ubuntu-server.seed initrd=/install/initrd.gz quiet -- Modified boot options noprompt cdrom-detect/try-usb=true persistent file=/cdrom/preseed/ubuntu-server.seed initrd=/install/initrd.gz -- Still I cannot install Ubuntu Server by USB as it, reboots when I hit 'enter' for 'Install Ubuntu Server' option. This is a real pain as we cannot take the 1tb Sata Hardrive and swap it for IDE to be able to use the cd drive. Why is is it so hard to install ubuntu server with usb? I have wasted a full day and half on this really frustrated any help would be amazing! I know the answers out there just seems a bit illusive at the moment! Computer Spec- Asus Motherboard, 1gb RAM 2X512MB, Powersupply 200watt, 2.8ghz Processor Intel, On-board 64mb graphics, 100mb Ethernet, 54mb Wireless,

    Read the article

  • SPARC T5-8 Servers EMEA Acceleration Promotion for Partners

    - by mseika
    Dear all We are pleased to announce the EMEA T5-8 Acceleration Promotion, a price promotion that, for a limited time, makes the T5-8 server available to our EMEA partners at a very attractive discount. Why the SPARC T5-8 server Oracle's SPARC servers running Oracle Solaris are ideal for mission-critical applications requiring high performance, best-in-class availability, and unmatched scalability on all application tiers. SPARC servers include built-in virtualization, systems management, and security at no additional cost. Designed for applications that demand the highest performance and 24x7 availability. Oracle's SPARC T5-8 server is the fastest and the most advanced, scalable midrange server in the Oracle portfolio. The Oracle SPARC T5-8 server is in the sweet spot of the UNIX midrange, and directly competing with IBM P770(+) and P780(+) systems, with a 7x price advantage (see official Oracle press release) over a similarly configured P780 system! What are we offering Effective immediately, the fully-configured T5-8 server is available to VADs with a 38% discount off price list: this is 8 additional points on top of the standard 30% contractual discount. The promo will be communicated to VADs and VARs, and VADs are expected to pass the additional discount through to the VARs. Resellers will be encouraged to use this attractive price to position T5-8 versus the competition, accelerate T5-8 sales, and use the increased margin to offer additional services to their end users - thus expanding their footprint within their customers and making the T5-8 business proposition even more compelling. This is a unique opportunity for partners to expand their base and beat the competition with a 7x price advantage over a similarly configured IBM P780. This price promotion is only available to OPN Partners, and is valid until November 30, 2013. What's in it for Partners  More competitive price More customer budget available for more projects: attach migration services, training, ... Opportunity to attach Storage, and additional Software Higher win rate Additional Details The promotion is valid for the existing configurations of T5-8 with 8 CPU and different memory configurations, including all X-options that are part of the system and ordered at the same time. 8% additional discount to the VAD on full T5-8 - Including X-Options: Cat V (30% + 8% additional): System, CPU, Memory, Disks, Ethernet Cat U (22% + 8% additional): Infiniband HCA Cat W (30% + 8% additional): FC/SAS HBA / FCoE CNA Partner eligibilty criteria Standard requirements apply. Partners must: be an OPN member in good standing, at Gold level or above meet the Resale criteria in the SPARC T-Series servers Knowledge Zone have a right to distribute hardware via the Full Use Distribution Agreement, with Hardware Addendum if applicable. Order process The promotion is available until November 30, 2013. VADs place the order via Oracle Partner Store. A request for extra-discount has to be raised in advance using the standard process for available configs: input the configuration apply the suggested discounts submit the request in the request documentation, please refer to EMEA T5-8 FY14H1 Channel Promotion as approved in GDMT GT-EB2-Q413-107C This promotion is only valid for the T5-8 configurations stated in this announcement. Any change, or additional products / items not listed explicitly, can be ordered at the same time and will follow standard approval process. Key contacts Your local A&C organization For questions on EMEA Partner Programs for Servers: Giuseppe Facchetti For questions on the T5-8 product: Martin de Jong Best regards, Olivier Tordo Senior Director, Sales & Strategy, Hardware SolutionsEMEA Alliances & Channels Paul Flannery Senior Director, EMEA Servers Product Management

    Read the article

  • SPARC T5-8 Servers EMEA Acceleration Promotion for Partners

    - by mseika
    Dear all We are pleased to announce the EMEA T5-8 Acceleration Promotion, a price promotion that, for a limited time, makes the T5-8 server available to our EMEA partners at a very attractive discount. Why the SPARC T5-8 server Oracle's SPARC servers running Oracle Solaris are ideal for mission-critical applications requiring high performance, best-in-class availability, and unmatched scalability on all application tiers. SPARC servers include built-in virtualization, systems management, and security at no additional cost. Designed for applications that demand the highest performance and 24x7 availability. Oracle's SPARC T5-8 server is the fastest and the most advanced, scalable midrange server in the Oracle portfolio. The Oracle SPARC T5-8 server is in the sweet spot of the UNIX midrange, and directly competing with IBM P770(+) and P780(+) systems, with a 7x price advantage (see official Oracle press release) over a similarly configured P780 system! What are we offering Effective immediately, the fully-configured T5-8 server is available to VADs with a 38% discount off price list: this is 8 additional points on top of the standard 30% contractual discount. The promo will be communicated to VADs and VARs, and VADs are expected to pass the additional discount through to the VARs. Resellers will be encouraged to use this attractive price to position T5-8 versus the competition, accelerate T5-8 sales, and use the increased margin to offer additional services to their end users - thus expanding their footprint within their customers and making the T5-8 business proposition even more compelling. This is a unique opportunity for partners to expand their base and beat the competition with a 7x price advantage over a similarly configured IBM P780. This price promotion is only available to OPN Partners, and is valid until November 30, 2013. What's in it for Partners  More competitive price More customer budget available for more projects: attach migration services, training, ... Opportunity to attach Storage, and additional Software Higher win rate Additional Details The promotion is valid for the existing configurations of T5-8 with 8 CPU and different memory configurations, including all X-options that are part of the system and ordered at the same time. 8% additional discount to the VAD on full T5-8 - Including X-Options: Cat V (30% + 8% additional): System, CPU, Memory, Disks, Ethernet Cat U (22% + 8% additional): Infiniband HCA Cat W (30% + 8% additional): FC/SAS HBA / FCoE CNA Partner eligibilty criteria Standard requirements apply. Partners must: be an OPN member in good standing, at Gold level or above meet the Resale criteria in the SPARC T-Series servers Knowledge Zone have a right to distribute hardware via the Full Use Distribution Agreement, with Hardware Addendum if applicable. Order process The promotion is available until November 30, 2013. VADs place the order via Oracle Partner Store. A request for extra-discount has to be raised in advance using the standard process for available configs: input the configuration apply the suggested discounts submit the request in the request documentation, please refer to EMEA T5-8 FY14H1 Channel Promotion as approved in GDMT GT-EB2-Q413-107C This promotion is only valid for the T5-8 configurations stated in this announcement. Any change, or additional products / items not listed explicitly, can be ordered at the same time and will follow standard approval process. Key contacts Your local A&C organization For questions on EMEA Partner Programs for Servers: Giuseppe Facchetti For questions on the T5-8 product: Martin de Jong Best regards, Olivier Tordo Senior Director, Sales & Strategy, Hardware SolutionsEMEA Alliances & Channels Paul Flannery Senior Director, EMEA Servers Product Management

    Read the article

  • SPARC T5-8 Servers EMEA Acceleration Promotion for Partners

    - by mseika
    Dear all We are pleased to announce the EMEA T5-8 Acceleration Promotion, a price promotion that, for a limited time, makes the T5-8 server available to our EMEA partners at a very attractive discount. Why the SPARC T5-8 server Oracle's SPARC servers running Oracle Solaris are ideal for mission-critical applications requiring high performance, best-in-class availability, and unmatched scalability on all application tiers. SPARC servers include built-in virtualization, systems management, and security at no additional cost. Designed for applications that demand the highest performance and 24x7 availability. Oracle's SPARC T5-8 server is the fastest and the most advanced, scalable midrange server in the Oracle portfolio. The Oracle SPARC T5-8 server is in the sweet spot of the UNIX midrange, and directly competing with IBM P770(+) and P780(+) systems, with a 7x price advantage (see official Oracle press release) over a similarly configured P780 system! What are we offering Effective immediately, the fully-configured T5-8 server is available to VADs with a 38% discount off price list: this is 8 additional points on top of the standard 30% contractual discount. The promo will be communicated to VADs and VARs, and VADs are expected to pass the additional discount through to the VARs. Resellers will be encouraged to use this attractive price to position T5-8 versus the competition, accelerate T5-8 sales, and use the increased margin to offer additional services to their end users - thus expanding their footprint within their customers and making the T5-8 business proposition even more compelling. This is a unique opportunity for partners to expand their base and beat the competition with a 7x price advantage over a similarly configured IBM P780. This price promotion is only available to OPN Partners, and is valid until November 30, 2013. What's in it for Partners  More competitive price More customer budget available for more projects: attach migration services, training, ... Opportunity to attach Storage, and additional Software Higher win rate Additional Details The promotion is valid for the existing configurations of T5-8 with 8 CPU and different memory configurations, including all X-options that are part of the system and ordered at the same time. 8% additional discount to the VAD on full T5-8 - Including X-Options: Cat V (30% + 8% additional): System, CPU, Memory, Disks, Ethernet Cat U (22% + 8% additional): Infiniband HCA Cat W (30% + 8% additional): FC/SAS HBA / FCoE CNA Partner eligibilty criteria Standard requirements apply. Partners must: be an OPN member in good standing, at Gold level or above meet the Resale criteria in the SPARC T-Series servers Knowledge Zone have a right to distribute hardware via the Full Use Distribution Agreement, with Hardware Addendum if applicable. Order process The promotion is available until November 30, 2013. VADs place the order via Oracle Partner Store. A request for extra-discount has to be raised in advance using the standard process for available configs: input the configuration apply the suggested discounts submit the request in the request documentation, please refer to EMEA T5-8 FY14H1 Channel Promotion as approved in GDMT GT-EB2-Q413-107C This promotion is only valid for the T5-8 configurations stated in this announcement. Any change, or additional products / items not listed explicitly, can be ordered at the same time and will follow standard approval process. Key contacts Your local A&C organization For questions on EMEA Partner Programs for Servers: Giuseppe Facchetti For questions on the T5-8 product: Martin de Jong Best regards, Olivier Tordo Senior Director, Sales & Strategy, Hardware SolutionsEMEA Alliances & Channels Paul Flannery Senior Director, EMEA Servers Product Management

    Read the article

  • SPARC T5-8 Servers EMEA Acceleration Promotion for Partners

    - by mseika
    Dear all We are pleased to announce the EMEA T5-8 Acceleration Promotion, a price promotion that, for a limited time, makes the T5-8 server available to our EMEA partners at a very attractive discount. Why the SPARC T5-8 server Oracle's SPARC servers running Oracle Solaris are ideal for mission-critical applications requiring high performance, best-in-class availability, and unmatched scalability on all application tiers. SPARC servers include built-in virtualization, systems management, and security at no additional cost. Designed for applications that demand the highest performance and 24x7 availability. Oracle's SPARC T5-8 server is the fastest and the most advanced, scalable midrange server in the Oracle portfolio. The Oracle SPARC T5-8 server is in the sweet spot of the UNIX midrange, and directly competing with IBM P770(+) and P780(+) systems, with a 7x price advantage (see official Oracle press release) over a similarly configured P780 system! What are we offering Effective immediately, the fully-configured T5-8 server is available to VADs with a 38% discount off price list: this is 8 additional points on top of the standard 30% contractual discount. The promo will be communicated to VADs and VARs, and VADs are expected to pass the additional discount through to the VARs. Resellers will be encouraged to use this attractive price to position T5-8 versus the competition, accelerate T5-8 sales, and use the increased margin to offer additional services to their end users - thus expanding their footprint within their customers and making the T5-8 business proposition even more compelling. This is a unique opportunity for partners to expand their base and beat the competition with a 7x price advantage over a similarly configured IBM P780. This price promotion is only available to OPN Partners, and is valid until November 30, 2013. What's in it for Partners  More competitive price More customer budget available for more projects: attach migration services, training, ... Opportunity to attach Storage, and additional Software Higher win rate Additional Details The promotion is valid for the existing configurations of T5-8 with 8 CPU and different memory configurations, including all X-options that are part of the system and ordered at the same time. 8% additional discount to the VAD on full T5-8 - Including X-Options: Cat V (30% + 8% additional): System, CPU, Memory, Disks, Ethernet Cat U (22% + 8% additional): Infiniband HCA Cat W (30% + 8% additional): FC/SAS HBA / FCoE CNA Partner eligibilty criteria Standard requirements apply. Partners must: be an OPN member in good standing, at Gold level or above meet the Resale criteria in the SPARC T-Series servers Knowledge Zone have a right to distribute hardware via the Full Use Distribution Agreement, with Hardware Addendum if applicable. Order process The promotion is available until November 30, 2013. VADs place the order via Oracle Partner Store. A request for extra-discount has to be raised in advance using the standard process for available configs: input the configuration apply the suggested discounts submit the request in the request documentation, please refer to EMEA T5-8 FY14H1 Channel Promotion as approved in GDMT GT-EB2-Q413-107C This promotion is only valid for the T5-8 configurations stated in this announcement. Any change, or additional products / items not listed explicitly, can be ordered at the same time and will follow standard approval process. Key contacts Your local A&C organization For questions on EMEA Partner Programs for Servers: Giuseppe Facchetti For questions on the T5-8 product: Martin de Jong Best regards, Olivier Tordo Senior Director, Sales & Strategy, Hardware SolutionsEMEA Alliances & Channels Paul Flannery Senior Director, EMEA Servers Product Management

    Read the article

  • Surface V2.0

    - by Dennis Vroegop
    It’s been quiet around here. And the reason for that is that it’s been quiet around Surface for a while. Now, a lot of people assume that when a product team isn’t making too much noise that must mean they stopped working on their product. Remember the PDC keynote in 2010? Just because they didn’t mention WPF there a lot of people had the idea that WPF was dead and abandoned for Silverlight. Of course, this couldn’t be farther from the truth. The same applies to Surface. While we didn’t hear much from the team in Redmond they were busy putting together the next version of the platform. And at the CES in January the world saw what they have been up to all along: Surface V2.0 as it’s commonly known. Of course, the product is still in development. It’s not here yet, we can’t buy one yet. However, more and more information comes available and I think this is a good time to share with you what it’s all about! The biggest change from an organizational point of view is that Microsoft decided to stop producing the hardware themselves. Instead, they have formed a partnership with Samsung who will manufacture the devices. This means that you as a buyer get the benefits of a large, worldwide supplier with all the services they can offer. Not that Microsoft didn’t do that before but since Surface wasn’t a ‘big’ product it was sometimes hard to get to the right people. The new device is officially called the “Samsung SUR 40 for Microsoft Surface” which is quite a mouthful. The software that runs the device is of course still coming from Microsoft. Let’s dive into the technical specs (note: all of this is preliminary, it’s still in the Alpha phase!): Audio out HDMI / StereoRCA / SPDIF / 2 times 3.5mm audio out jack Brightness 300 CD/m2 Communications 1GB Ethernet/802.11/Bluetooth Contrast Ratio 1:1000 CPU AMD Athlon X2 245e 2.9Ghz Dual Core Display Resolution Full HD 1080p 1920x1080 / 16:9 aspect ratio GPU AMD Radeon HD 6750 1GB GDDRS HDD 320 GB / 7200 RPM HDMI In / HDMI out Yes I/O Ports 4 USB, SD Card reader Operation System Embedded Windows 7 Professional 64 bits Panel Size 40” diagonal Protection Glass Gorilla Glass RAM 4 GB DD3 Weight / with standard legs 70.0 Kg / 154 lbs Weight / standalone 39.5 Kg / 87 lbs Height (without legs) 4 inch Contact points recognized > 50 Cool Factor Extremely   Ok, the last point is not official, but I do think it needs to be there. Let’s talk software. As noted, it runs Windows 7 Professional 64 bit, which means you can run Visual Studio 2010 on it. The software is going to be developed in WPF4.0 with the additional Surface SDK 2.0. It will contain all the things you’ve seen before plus some extra’s. They have taken some steps to align it more with the Surface Toolkit which you can download today, so if you do things right your software should be portable between a WPF4.0 Windows 7 Multi-touch app and the Surface v2 environment. It still uses infrared to detect contacts, so in that respect nothing much has changed conceptually. We still can differentiate between a finger, a tag or a blob. Of course, since the new platform has a much higher resolution (compared to the 1024x768 of the first version) you might need to look at your code again. I’ve seen a lot of applications on Surface that assume the old resolution and moving that to V2 is going to be some work. To be honest: as I am under NDA I cannot disclose much about the new software besides what I have told you here, but trust me: it’s going to blow people away. Now, the biggest question for me is: when can I get one? Until we can, have a look here: Tags van Technorati: surface,samsung,WPF

    Read the article

  • Hyper-V Live Migration across Sites!

    - by Ryan Roussel
    One of the great sessions I sat in on at Tech Ed this week was stretching a Windows 2008 R2 Hyper-V  Failover Cluster across sites.  With this ability, you could actually implement a Hyper-V cluster where you could migrate or even Live Migrate VMs across sites.   With this area’s propensity for Hurricanes, this will be a very popular topic for me over the next few months. While this technology is possible today, it’s also very complicated and can be very expensive to implement.    First your WAN connection has to support the ability to trunk your VLAN across both sites in order to Live Migrate.  This means you can’t use a Layer 3 routed connection like MPLS.  It has to be a Metro Ethernet connection or "Dark Fiber”.  Dark Fiber is unused Fiber already in the ground that can be leased from  various providers. Both of these connections would allow you to trunk layer 2 across your WAN.  Cisco does have the ability to trunk layer 2 across a routed connection by muxing the traffic but this is only available in their Nexus product line which has a very steep price tag.   If you are stuck with MPLS or the like and Nexus switching is not a realistic possibility, you will have to implement a multi-subnet cluster in which case Live Migration won’t be possible.  However you can still failover VMs to the remote site with some planning and manual intervention.  The consideration here is that the VMs will be on a different subnet once migrated, so you will have to change the IP addressing of your VMs.  This also has ramifications with DNS and Name resolution to control your down time.  DHCP with Reservations for your VMs is the preferred method to achieve the IP changes as this will automate that part of the process.   Secondly, you will have to have  a mechanism to replicate your storage across both sites.  Many SAN vendors natively support hardware based synchronous and asynchronous replication.  Some even support cluster shared volumes which were introduced in 2008 R2.   If your SANs do not support this natively, there are alternative file based replication products either software based like Double Take or hardware appliance like EMC.  Be sure to check with your vendor on the support of Disk majority if you’re replicating your quorum disk between SANs.   The last consideration is the ability to maintain quorum for your cluster.  If your replication provider does not support Disk Majority through replication, you will have to explore Node Majority with File Share Witness.  This will affect your design as a 3 node cluster with 1 node at the remote site and FSW at the production site would not have the ability to maintain quorum if the production site was lost. MS best practice for this would be to implement an even node cluster with 2 nodes at  each site and the FSW at a third site.   And there you have it.  While some considerations and research goes into implementing this solution, even a multi-subnet solution would be invaluable to organizations in the implementations of “warm” DR sites.

    Read the article

  • Controlling server configurations with IPS

    - by barts
    I recently received a customer question regarding how they best could control which packages and which versions were used on their production Solaris 11 servers.  They had considered pointing each server at its own software repository - a common initial approach.  A simpler method leverages one of dependency mechanisms we introduced with Solaris 11, but is not immediately obvious to most people. Typically, most internal IT departments qualify particular versions for production use.  What this customer wanted to do was insure that their operations staff only installed internally qualified versions of Solaris on their servers.  The easiest way of doing this is to leverage the 'incorporate' type of dependency in a small package defined for each server type.  From the reference " Packaging and Delivering Software With the Image Packaging System in Oracle® Solaris 11.1":  The incorporate dependency specifies that if the given package is installed, it must be at the given version, to the given version accuracy. For example, if the dependent FMRI has a version of 1.4.3, then no version less than 1.4.3 or greater than or equal to 1.4.4 satisfies the dependency. Version 1.4.3.7 does satisfy this example dependency. The common way to use incorporate dependencies is to put many of them in the same package to define a surface in the package version space that is compatible. Packages that contain such sets of incorporate dependencies are often called incorporations. Incorporations are typically used to define sets of software packages that are built together and are not separately versioned. The incorporate dependency is heavily used in Oracle Solaris to ensurethat compatible versions of software are installed together. An example incorporate dependency is: depend type=incorporate fmri=pkg:/driver/network/ethernet/[email protected],5.11-0.175.0.0.0.2.1 So, to make sure only qualified versions are installed on a server, create a package that will be installed on the machines to be controlled.  This package will contain an incorporate dependency on the "entire" package, which controls the various components used to be build Solaris.  Every time a new version of Solaris has been qualified for production use, create a new version of this package specifying the new version of "entire" that was qualified.  Once this new control package is available in the repositories configured on the production server, the pkg update command will update that system to the specified version.  Unless a new version of the control package is made available, pkg update will report that no updates are available since no version of the control package can be installed that satisfies the incorporate constraint. Note that if desired, the same package can be used to specify which packages must be present on the system by adding either "require" or "group" dependencies; the latter permits removal of some of the packages, the former does not.  More details on this can be found in either the section 5 pkg man page or the previously mentioned reference document. This technique of using package dependencies to constrain system configuration leverages the SAT solver which is at the heart of IPS, and is basic to how we package Solaris itself.  

    Read the article

  • Access denied error while mounting a shared folder?

    - by SSH
    I am a linux newbie and I have a very basic question. I have three machines - machineA 10.108.24.132 machineB 10.108.24.133 machineC 10.108.24.134 and all those machines have Ubuntu 12.04 installed in it and I have root access to all those three machines. Now I am supposed to do below things in my above machines - Create mount point /opt/exhibitor/conf Mount the directory in all servers. sudo mount <NFS-SERVER>:/opt/exhibitor/conf /opt/exhibitor/conf/ I have already created /opt/exhibitor/conf directory in all those three machines as mentioned above. Now I am trying to create a Mount Point on all those three machines. So I followed the below process - Install NFS support files and NFS kernel server in all the above three machines $ sudo apt-get install nfs-common nfs-kernel-server Create the shared directory in all the above three machines $ mkdir /opt/exhibitor/conf/ Edited the /etc/exports and added the entry like this in all the above three machines - # /etc/exports: the access control list for filesystems which may be exported # to NFS clients. See exports(5). # # Example for NFSv2 and NFSv3: # /srv/homes hostname1(rw,sync,no_subtree_check) hostname2(ro,sync,no_subtree_check) # # Example for NFSv4: # /srv/nfs4 gss/krb5i(rw,sync,fsid=0,crossmnt,no_subtree_check) # /srv/nfs4/homes gss/krb5i(rw,sync,no_subtree_check) # /opt/exhibitor/conf/ 10.108.24.*(rw) Run exportfs in all the above three machines root@machineA:/# exportfs -rv exportfs: /etc/exports [1]: Neither 'subtree_check' or 'no_subtree_check' specified for export "10.108.24.*:/opt/exhibitor/conf/". Assuming default behaviour ('no_subtree_check'). NOTE: this default has changed since nfs-utils version 1.0.x exporting 10.108.24.*:/opt/exhibitor/conf Now I did showmount on machineA root@machineA:/# showmount -e 10.108.24.132 Export list for 10.108.24.132: /opt/exhibitor/conf 10.108.24.* And also I have started the NFS server like this in all the above three machines - sudo /etc/init.d/nfs-kernel-server start And now when I did this, I am getting an error - root@machineA:/# sudo mount -t nfs 10.108.24.132:/opt/exhibitor/conf /opt/exhibitor/conf/ mount.nfs: access denied by server while mounting 10.108.24.132:/opt/exhibitor/conf I have also tried doing the same thing from machineB and machineC as well and still I get the same error- root@machineB:/# sudo mount -t nfs 10.108.24.132:/opt/exhibitor/conf /opt/exhibitor/conf/ root@machineC:/# sudo mount -t nfs 10.108.24.132:/opt/exhibitor/conf /opt/exhibitor/conf/ Did my /etc/exports file looks good? As I have the same content in all the three machines. And also are there any logs related to NFS which I can see to find any clues? Any idea what wrong I am doing here? UPDATE:- So my etc/exports files would be like this in all the three machines - # /etc/exports: the access control list for filesystems which may be exported # to NFS clients. See exports(5). # # Example for NFSv2 and NFSv3: # /srv/homes hostname1(rw,sync,no_subtree_check) hostname2(ro,sync,no_subtree_check) # # Example for NFSv4: # /srv/nfs4 gss/krb5i(rw,sync,fsid=0,crossmnt,no_subtree_check) # /srv/nfs4/homes gss/krb5i(rw,sync,no_subtree_check) # /opt/exhibitor/conf/ 10.108.24.132(rw) /opt/exhibitor/conf/ 10.108.24.133(rw) /opt/exhibitor/conf/ 10.108.24.134(rw) Just a quick check - The IP Address that I am taking for each machine as mentioned above is like this - root@machineB:/# ifconfig eth0 Link encap:Ethernet HWaddr 00:50:56:ad:5b:a7 inet addr:10.108.24.133 Bcast:10.108.27.255 Mask:255.255.252.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:5696812 errors:0 dropped:12462 overruns:0 frame:0 TX packets:5083427 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:7904369145 (7.9 GB) TX bytes:601844910 (601.8 MB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:187144 errors:0 dropped:0 overruns:0 frame:0 TX packets:187144 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:24012302 (24.0 MB) TX bytes:24012302 (24.0 MB) Here the IP Address that I am taking for machineB is 10.108.24.133.

    Read the article

  • Why won't my Broadcom BCM4312 LP-PHY work with the STA driver?

    - by Jackson Taylor
    I tried the steps here for a 4312: https://help.ubuntu.com/community/WifiDocs/Driver/bcm43xx Both of these: sudo modprobe -r b43 ssb wl sudo modprobe wl return: FATAL: Module wl not found. FATAL: Error running install command for wl (this one is only for the second one actually) I tried the broadcom-sta, didn't work. What's confusing is down below in the next steps for STA with internet access it says to use the bcmwl one. So I install that and it succeeds but with some errors: sudo apt-get install bcmwl-kernel-source Reading package lists... Done Building dependency tree Reading state information... Done The following package was automatically installed and is no longer required: module-assistant Use 'apt-get autoremove' to remove it. The following NEW packages will be installed: bcmwl-kernel-source 0 upgraded, 1 newly installed, 0 to remove and 0 not upgraded. Need to get 0 B/1,181 kB of archives. After this operation, 3,609 kB of additional disk space will be used. Selecting previously unselected package bcmwl-kernel-source. (Reading database ... 168005 files and directories currently installed.) Unpacking bcmwl-kernel-source (from .../bcmwl-kernel-source_5.100.82.112+bdcom-0ubuntu3_amd64.deb) ... Setting up bcmwl-kernel-source (5.100.82.112+bdcom-0ubuntu3) ... Loading new bcmwl-5.100.82.112+bdcom DKMS files... Building only for 3.5.0-21-generic Building for architecture x86_64 Module build for the currently running kernel was skipped since the kernel source for this kernel does not seem to be installed. ERROR: Module b43 does not exist in /proc/modules ERROR: Module b43legacy does not exist in /proc/modules ERROR: Module ssb does not exist in /proc/modules ERROR: Module bcm43xx does not exist in /proc/modules ERROR: Module brcm80211 does not exist in /proc/modules ERROR: Module brcmfmac does not exist in /proc/modules ERROR: Module brcmsmac does not exist in /proc/modules ERROR: Module bcma does not exist in /proc/modules FATAL: Module wl not found. FATAL: Error running install command for wl update-initramfs: deferring update (trigger activated) Processing triggers for initramfs-tools ... update-initramfs: Generating /boot/initrd.img-3.5.0-21-generic jtaylor991@jtaylor991-whiteHP:~$ sudo modprobe wl FATAL: Module wl not found. FATAL: Error running install command for wl Then I do the modprobe wl commands listed above and it gives the above listed errors. It didn't work with the broadcom-sta driver either. I installed the b43 ones but nothing happened, and I don't know why so those are still installed. firmware-b43legacy-installer, b43-fwcutter and firmware-b43-lpphy-installer (yes it is a LP-PHY) are currently installed. If I go into System Settings Software Sources Additional Drivers it says "Using Broadcom 802.11 Linux STA wireless driver source from bcmwl-kernel-source (proprietary) But bcmwl-kernel-source isn't installed. I could try again but I remember rebooting and it still said this. What's funny is it found wireless networks during the Ubuntu setup/installation, I don't remember if I got it to connect or not though. I think it kept asking for a password when I put it in (yes it was right I showed password and looked at it) so I just ignored it. But right now the Enable Wireless option in the top right is just gone, it's just Enable Networking and I'm on ethernet on this HP Pavilion dv4-1435dx right here. If I run rfkill list it shows: 0: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: no It was hard blocked at the beginning but unblocking it makes no change. Also it's a touch sensitive button, and it appears to be always orange no matter if it's enabled or not because when I touch it the hard blocked changes between yes and no in rfkill list. I think it was blue for a minute at one point. What is going on?!?! Help me! Lol, thanks for any and all of your time guys. Oh yeah this is Ubuntu 12.10 fresh install.

    Read the article

  • No Wireless Networks, BCM4313 [duplicate]

    - by TalonPlz
    This question already has an answer here: How to Install Broadcom Wireless Drivers (BCM43xx) 38 answers Just bought this little Asus 10 inch laptop that came with Ubuntu 12.04. Everything at my home was fine: Wireless identified and connected. As soon as I went to my girlfriend's house the trouble started. I couldn't connect to wireless (authentication... times out and asks for authentication) I started doing internet searching, tried a few solutions posted on line using terminal commands. No solutions. I decided to upgraded to 12.10-13.04 and that left me with a worse problem: I can no longer see ANY networks what so ever. Wireless card is ON, with out a doubt. Wired connection works. I have been fumbling with driver versions to no .avail, and have no idea which driver I am currently running I have a vague idea of what terminal lines to run: lshw: resources: irq:17 memory:f7d00000-f7dfffff *-network description: Wireless interface product: BCM4313 802.11b/g/n Wireless LAN Controller vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:02:00.0 logical name: eth2 version: 01 serial: dc:85:de:56:c4:ea width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=wl0 driverversion=6.20.155.1 (r326264) latency=0 multicast=yes wireless=IEEE 802.11abg resources: irq:17 memory:f7d00000-f7d03fff iwconfig: eth1 no wireless extensions. eth2 IEEE 802.11abg ESSID:off/any Mode:Managed Access Point: Not-Associated Retry long limit:7 RTS thr:off Fragment thr:off Power Management:off lo no wireless extensions. I am new and excited to start my Ubuntu and Linux life and this is only the first of my few hic cups i am sure! :) Thanks all UPDATE: Report from 2nd answer talon@Black1015E:~$ sudo apt-get remove --purge bcmwl-kernel-source [sudo] password for talon: Reading package lists... Done Building dependency tree Reading state information... Done Package 'bcmwl-kernel-source' is not installed, so not removed 0 upgraded, 0 newly installed, 0 to remove and 0 not upgraded. talon@Black1015E:~$ wget http://us.archive.ubuntu.com/ubuntu/pool/restricted/b/bcmwl/bcmwl-kernel-source_5.100.82.112+bdcom-0ubuntu3_amd64.deb --2013-10-22 18:50:32-- http://us.archive.ubuntu.com/ubuntu/pool/restricted/b/bcmwl/bcmwl-kernel-source_5.100.82.112+bdcom-0ubuntu3_amd64.deb Resolving us.archive.ubuntu.com (us.archive.ubuntu.com)... 2001:67c:1562::15, 2001:67c:1562::13, 2001:67c:1562::14, ... Connecting to us.archive.ubuntu.com (us.archive.ubuntu.com)|2001:67c:1562::15|:80... connected. HTTP request sent, awaiting response... 200 OK Length: 1181334 (1.1M) [application/x-debian-package] Saving to: ‘bcmwl-kernel-source_5.100.82.112+bdcom-0ubuntu3_amd64.deb’ 100%[======================================>] 1,181,334 3.37MB/s in 0.3s 2013-10-22 18:50:33 (3.37 MB/s) - ‘bcmwl-kernel-source_5.100.82.112+bdcom-0ubuntu3_amd64.deb’ saved [1181334/1181334] talon@Black1015E:~$ arvh No command 'arvh' found, did you mean: Command 'arch' from package 'coreutils' (main) arvh: command not found talon@Black1015E:~$ arch x86_64 talon@Black1015E:~$ sudo dpkg -i bcmwl*.deb Selecting previously unselected package bcmwl-kernel-source. (Reading database ... 171895 files and directories currently installed.) Unpacking bcmwl-kernel-source (from bcmwl-kernel-source_5.100.82.112+bdcom-0ubuntu3_amd64.deb) ... Setting up bcmwl-kernel-source (5.100.82.112+bdcom-0ubuntu3) ... Loading new bcmwl-5.100.82.112+bdcom DKMS files... First Installation: checking all kernels... Building only for 3.8.0-32-generic Building for architecture x86_64 Building initial module for 3.8.0-32-generic Done. wl: Running module version sanity check. - Original module - No original module exists within this kernel - Installation - Installing to /lib/modules/3.8.0-32-generic/updates/dkms/ depmod........ DKMS: install completed. Error: Module b43 is not currently loaded Error: Module b43legacy is not currently loaded Error: Module ssb is not currently loaded Error: Module bcm43xx is not currently loaded Error: Module brcm80211 is not currently loaded Error: Module brcmfmac is not currently loaded update-initramfs: deferring update (trigger activated) Processing triggers for initramfs-tools ... update-initramfs: Generating /boot/initrd.img-3.8.0-32-generic rebooting now

    Read the article

  • Security Access Control With Solaris Virtualization

    - by Thierry Manfe-Oracle
    Numerous Solaris customers consolidate multiple applications or servers on a single platform. The resulting configuration consists of many environments hosted on a single infrastructure and security constraints sometimes exist between these environments. Recently, a customer consolidated many virtual machines belonging to both their Intranet and Extranet on a pair of SPARC Solaris servers interconnected through Infiniband. Virtual Machines were mapped to Solaris Zones and one security constraint was to prevent SSH connections between the Intranet and the Extranet. This case study gives us the opportunity to understand how the Oracle Solaris Network Virtualization Technology —a.k.a. Project Crossbow— can be used to control outbound traffic from Solaris Zones. Solaris Zones from both the Intranet and Extranet use an Infiniband network to access a ZFS Storage Appliance that exports NFS shares. Solaris global zones on both SPARC servers mount iSCSI LU exported by the Storage Appliance.  Non-global zones are installed on these iSCSI LU. With no security hardening, if an Extranet zone gets compromised, the attacker could try to use the Storage Appliance as a gateway to the Intranet zones, or even worse, to the global zones as all the zones are reachable from this node. One solution consists in using Solaris Network Virtualization Technology to stop outbound SSH traffic from the Solaris Zones. The virtualized network stack provides per-network link flows. A flow classifies network traffic on a specific link. As an example, on the network link used by a Solaris Zone to connect to the Infiniband, a flow can be created for TCP traffic on port 22, thereby a flow for the ssh traffic. A bandwidth can be specified for that flow and, if set to zero, the traffic is blocked. Last but not least, flows are created from the global zone, which means that even with root privileges in a Solaris zone an attacker cannot disable or delete a flow. With the flow approach, the outbound traffic of a Solaris zone is controlled from outside the zone. Schema 1 describes the new network setting once the security has been put in place. Here are the instructions to create a Crossbow flow as used in Schema 1 : (GZ)# zoneadm -z zonename halt ...halts the Solaris Zone. (GZ)# flowadm add-flow -l iblink -a transport=TCP,remote_port=22 -p maxbw=0 sshFilter  ...creates a flow on the IB partition "iblink" used by the zone to connect to the Infiniband.  This IB partition can be identified by intersecting the output of the commands 'zonecfg -z zonename info net' and 'dladm show-part'.  The flow is created on port 22, for the TCP traffic with a zero maximum bandwidth.  The name given to the flow is "sshFilter". (GZ)# zoneadm -z zonename boot  ...restarts the Solaris zone now that the flow is in place.Solaris Zones and Solaris Network Virtualization enable SSH access control on Infiniband (and on Ethernet) without the extra cost of a firewall. With this approach, no change is required on the Infiniband switch. All the security enforcements are put in place at the Solaris level, minimizing the impact on the overall infrastructure. The Crossbow flows come in addition to many other security controls available with Oracle Solaris such as IPFilter and Role Based Access Control, and that can be used to tackle security challenges.