Search Results

Search found 20693 results on 828 pages for '24 hours of pass'.

Page 97/828 | < Previous Page | 93 94 95 96 97 98 99 100 101 102 103 104  | Next Page >

  • how to fix error with ati driver ubuntu 11.10 X Error of failed request?

    - by user34785
    i install driver by this link : http://cisight.com/install-amd-radeon-hd-6470m-and-solve-overheat-on-ubuntu-1110-oneiric/ but will time i run fglrxinfo , display it : X Error of failed request: BadRequest (invalid request code or no such operation) Major opcode of failed request: 136 (GLX) Minor opcode of failed request: 19 (X_GLXQueryServerString) Serial number of failed request: 12 Current serial number in output stream: 12 my xorg is : Section "ServerLayout" Identifier "aticonfig Layout" Screen 0 "aticonfig-Screen[0]-0" 0 0 EndSection Section "Module" Load "fglrx" EndSection Section "Monitor" Identifier "aticonfig-Monitor[0]-0" Option "VendorName" "ATI Proprietary Driver" Option "ModelName" "Generic Autodetecting Monitor" Option "DPMS" "true" EndSection Section "Screen" Identifier "aticonfig-Screen[0]-0" Device "aticonfig-Device[0]-0" Monitor "aticonfig-Monitor[0]-0" DefaultDepth 24 SubSection "Display" Viewport 0 0 Depth 24 EndSubSection EndSection how may i solve it? thanks

    Read the article

  • How to make grub stop appearing every time I boot?

    - by Justin Riddiough
    I'm using Ubuntu 12.04 and grub selections appear each time I boot. This happens on both of my computers. I have tried editing the /etc/defaults/grub to use default, to use the 0 entry, and ran the update on it. But nothing seems to solve the problem. (showing uncommented lines) $ sudo nano /etc/default/grub GRUB_DEFAULT=0 GRUB_HIDDEN_TIMEOUT=0 GRUB_HIDDEN_TIMEOUT_QUIET=true GRUB_TIMEOUT=10 GRUB_DISTRIBUTOR=`lsb_release -i -s 2> /dev/null || echo Debian` GRUB_CMDLINE_LINUX_DEFAULT="quiet splash" GRUB_CMDLINE_LINUX="" $ sudo update-grub Generating grub.cfg ... Found linux image: /boot/vmlinuz-3.2.0-25-generic-pae Found initrd image: /boot/initrd.img-3.2.0-25-generic-pae Found linux image: /boot/vmlinuz-3.2.0-24-generic-pae Found initrd image: /boot/initrd.img-3.2.0-24-generic-pae Found memtest86+ image: /boot/memtest86+.bin No volume groups found done

    Read the article

  • How to get rid of multiple linux versions in grub boot menu

    - by Silver Light
    I've been using dual boot on my PC for some time now, to use Ubuntu along side with Windows 7. One very disturbing thing happens, when Ubuntu linux core gets updated (this happens once in a while). They are added as options to the grub menu so, my boot menu now looks like this: Ubuntu, with linux 2.6.35-27 generic Ubuntu, with linux 2.6.35-27 generic (recovery mode) Ubuntu, with linux 2.6.35-25 generic Ubuntu, with linux 2.6.35-25 generic (recovery mode) Ubuntu, with linux 2.6.35-24 generic Ubuntu, with linux 2.6.35-24 generic (recovery mode) Ubuntu, with linux 2.6.35-22 generic Ubuntu, with linux 2.6.35-22 generic (recovery mode) Memory test Windows 7 This gets very annoying, because I want to load windows by default, but after every update it shifts down and I have to go to grub config and change the default option. My question: How to get rid of older versions of linux in the grub menu and leave only the newest one?

    Read the article

  • Domain mapping issues

    - by Nadya
    I have two domain names - .com & .co.uk bought with 123-reg and just one student Windows hosting pack associated with the .co.uk domain. The .com domain is the main one which people would be trying to access, so I just mapped the domain to the hosting this morning. The problem is that I would really like it to be functional by tomorrow morning and the usual waiting time is 24-48 hours. Is there point in stopping the process and trying with forward it with CNAME record instead, does it take less time? (I can just go back and do proper domain mapping during the weekend) Also, is there a possible way to check whether the domain mapping has been done correctly before these 24-48 hours? From some computers I get 404 Error on homepage.

    Read the article

  • Alternatives to time tracking methodologies [closed]

    - by Brandon Wamboldt
    Question first: What are some feasible alternatives to time tracking for employees in a web/software development company, and why are they better options Explanation: I work at a company where we work like this. Everybody is paid salary. We have 3 types of work, Contract, Adhoc and Internal (Non billable). Adhoc is just small changes that take a few hours and we just bill the client at the end of the month. Contracts are signed and we have this big long process, the usual. We figure out how much to charge by getting an estimation of the time involved (From the design and the developers), multiplying it by our hourly rate and that's it. So say we estimate 50 hours for a website. We have time tracking software and have to record the time in 15 we spend on it (7:00 to 7:15 for example), the project name, and give it some comments. Now if we go over the 50 hours, we are both losing money and are inefficient. Now that I've explained how the system works, my question is how else can it be done if a better method exists (Which I'm sure one must). Nobody here likes the current system, we just can't find an alternative. I'd be more than willing to work after hours longer hours on a project to get it done in time, but I'm much inclined to do so with the current system. I'd love to be able to sum up (Or link) to this post for my manager to show them why we should use abc system instead of this system.

    Read the article

  • Case studies for successful service (project) based software development businesses without constant overtime from its employees [closed]

    - by Ryan Taylor
    I work for an IT company that is primarily services (project) based rather than product based. All software engineers are salaried. The company has set new expectations that everyone should work 48 hours per week instead of 40. Note, this isn't occasional overtime due to crunches. This is the new 40. The reasoning is that this enables the company to provide benefits to its employees such as monetary incentives and training because the company is more profitable. more hours worked = more billable hours = larger profit I understand the need for profitability and the occasional crunch time and have put in the extra hours when it was needed and beneficial to the project. However, I am also very sensitive to work life balance and have raised my concerns about the the new expectation. My employer is open to other methods to increase profitability so I hold hope that we can turn things around before it becomes a horrible place to work. How does a services based company become more profitable without increasing the number of hours expected from it's salaried employees? Are there any case studies showing the pros and cons of consistent overtime? Are there any case studies for a successful service based business model (for software development companies) that does not require consistent overtime from its employees?

    Read the article

  • vb.net how to start a folder monitor service at runtime and pass on the folder path to monitor?

    - by mazrabul
    hi, I have the following windows service file: Imports System.ServiceProcess Imports System.IO Public Class fswService Dim fsw As FileSystemWatcher Dim lf As StreamWriter Protected Overrides Sub OnStart(ByVal args As String()) ' Add code here to start your service. This method should set things ' in motion so your service can do its work. lf = New StreamWriter(Application.StartupPath & "\fsw_lg.log") fsw = New FileSystemWatcher() fsw.Path = args(0) fsw.IncludeSubdirectories = True fsw.Filter = ".txt" fsw.EnableRaisingEvents = True AddHandler fsw.Created, New FileSystemEventHandler(AddressOf file_created) AddHandler fsw.Changed, New FileSystemEventHandler(AddressOf file_changed) AddHandler fsw.Deleted, New FileSystemEventHandler(AddressOf file_deleted) End Sub Public Sub file_created(ByVal obj As Object, ByVal e As FileSystemEventArgs) lf.WriteLine(Now.ToShortDateString & "-" & Now.ToShortTimeString & "-" & e.FullPath & "-created") End Sub Public Sub file_changed(ByVal obj As Object, ByVal e As FileSystemEventArgs) lf.WriteLine(Now.ToShortDateString & "-" & Now.ToShortTimeString & "-" & e.FullPath & "-changed") End Sub Public Sub file_deleted(ByVal obj As Object, ByVal e As FileSystemEventArgs) lf.WriteLine(Now.ToShortDateString & "-" & Now.ToShortTimeString & "-" & e.FullPath & "-deleted") End Sub Protected Overrides Sub OnStop() lf.Close() End Sub End Class i have the ServiceName set to fswService (same as class name). When I added an installer I also set the ServiceName for the ServiceInstaller1 as fswService. I want to start this service at runtime based on the user setting the path of the folder to be watched. To achieve this I have the following: Dim fsw_controller As New ServiceProcess.ServiceController fsw_controller.Start(fswService) 2 problems: first, intellisense error saying: 'fswService' is a type and cannot be used as an expression. second, I can not figure out a way to pass on to the service the path of the folder to watch (which is stored at My.Settings.userPath). I really thought this is how you start a service. Am I missing something? Your help is, as always, appreciated. Thanks

    Read the article

  • Hello Again, San Francisco

    - by Geertjan
    From the moment I got to the airport in Amsterdam, I've been bumping into JavaOne pilgrims today. Finally got to my hotel, after a pretty good flight (and KLM provides great meals, which helps a lot), and a rather long wait at customs (serves me right for getting seat 66C in a plane with 68 rows). And, best of all, on Twitter I've been seeing a few remarks around the Duke's Choice Awards for this year. The references all point to the September - October issue of the Java Magazine, where page 24 shows the following: So, from page 24 onwards, you can read all about the above applications. What's especially cool is that three of the above are applications created on top of the NetBeans Platform! That's AgroSense (farm management software), MICE (NATO system for defense and battle-space operations), and Level One Registration Tool (UN Refugee Agency sofware for managing refugees). Congratulations to all the winners, looking forward to learning more about them all during the coming days here at the conference.

    Read the article

  • Passing arguments between classes - use public properties or pass a properties class as argument?

    - by devoured elysium
    So let's assume I have a class named ABC that will have a list of Point objects. I need to make some drawing logic with them. Each one of those Point objects will have a Draw() method that will be called by the ABC class. The Draw() method code will need info from ABC class. I can only see two ways to make them have this info: Having Abc class make public some properties that would allow draw() to make its decisions. Having Abc class pass to draw() a class full of properties. The properties in both cases would be the same, my question is what is preferred in this case. Maybe the second approach is more flexible? Maybe not? I don't see here a clear winner, but that sure has more to do with my inexperience than any other thing. If there are other good approaches, feel free to share them. Here are both cases: class Abc1 { public property a; public property b; public property c; ... public property z; public void method1(); ... public void methodn(); } and here is approach 2: class Abc2 { //here we make take down all properties public void method1(); ... public void methodn(); } class Abc2MethodArgs { //and we put them here. this class will be passed as argument to //Point's draw() method! public property a; public property b; public property c; ... public property z; } Also, if there are any "formal" names for these two approaches, I'd like to know them so I can better choose the tags/thread name, so it's more useful for searching purposes. That or feel free to edit them.

    Read the article

  • Screen Resolution Change

    - by user75997
    Good Evening members 1) Recently i have installed the plymouth manager and i accidentally set my resolution to 1024X768-24 which does not fit my laptop exactly and everytime my system reboots an error message shows that error: incorrect settings 1024X768-24. I tried to change the resolution from the system seetings Display but now only this 1024X768 is shown in the drop down. Kindly help me to reset the display properties to default. 2) Additionally plymouth is also not responding when i click on it and i want to uninstall it kindly help me in that too. Thank You K.Arun Kumar

    Read the article

  • Ubuntu 12.04 LTS Purple Screen Error. FIX

    - by user100918
    When I boot up my Ubuntu, it hangs on the purple screen. All I can do is press Shift on start up and it gives me these 3 options. -Normal Boot -Perform Disk Scan -Restore Factory Settings I can also either press E or C. C for for GRUB command line. E for GNU GRUB and says these things setparams 'Restore Factory Settings' set gfxpayload=text insmod part_msdos insmod ext2 set root='(hd0,nsdos1)' linux /boot/vmlinuz-3.3.8-24-generic root=LABEL=SYSTEM ro acpi_osi_=Linux acpi_backlight=\ vendor quiet aufs=restore initrd /boot/initrd.img=3.3.8-24-aufs What is the problem and how do

    Read the article

  • Toggle Fullscreen at Runtime

    - by sharethis
    Using the library GLFW, I can create a fullscreen window using this line of code. glfwOpenWindow(Width, Height, 8, 8, 8, 8, 24, 0, GLFW_FULLSCREEN); The line for creating a standard window looks like this. glfwOpenWindow(Width, Height, 8, 8, 8, 8, 24, 0, GLFW_WINDOW); What I want to do is letting the user switch between standard window and fullscreen by a keypress, let's say F11. It there a common practice of toggling fullscreen mode? What do I have to consider?

    Read the article

  • which one is the safe site to buy cheap wildstar gold?

    - by user50866
    Wsoplat.com is a professional online shop which provide the cheapest wildstar gold, the fastest delivery, the best 24/7 online service for the players. Secure Guarantee cheap wildstar gold offered by wsoplat.com are reliable sourced, safe and honored. Lowest Price We are constantly trying to offer the lowest prices on Wildstar Gold for our loyal customers. Covenient shopping procedure & secure delivery method We are very experienced in this business. Every order is processed both smoothly and efficiently. Friendly Service and Instant Delivery Wsoplat 's delivery department work 24/7/365, We have professional and friendly customer service operators, they can help you buy wildstar gold, accounts, items and more. 5% discount code to buy WildStar gold in wsoplat - WSOPLAT http://www.wsoplat.com/

    Read the article

  • jQuery autocomplete. Doesn't reveal existing matches.

    - by Alexander
    Hello fellow engineers. I have come across a problem I just can't solve. I am using autocomplete plugin for jQuery on an input. The HTML looks something like this: <tr id="row_house" class="no-display"> <td class="col_num">4</td> <td class="col_label">House Number</td> <td class="col_data"> <input type="text" title="House Number" name="house" id="house"/> <button class="pretty_button ui-state-default ui-corner-all button-finish">Get house info</button> </td> </tr> I am sure that this is the only id="house" field. Other fields that are before this one work fine with autocomplete, and it's basically the same algorithm (other variables, other data, other calls). So why doesn't it work like it should work with the following init. code: $("#house").autocomplete(["1/4","6","6/1","6/4","8","8/1","8/5","10","10/1","10/3","10/4","12","12/1","12/5","12/6","14","14/1","15","15/1","15/2","15/4","15/5","16","16/1","16/2","16/21","16/2B","16/3","16/4","17","17/1","17/2","17/4","17/5","17/6","17/7","17/8","18","18/1","18/2","18/3","18/5","18/95","19","19/1","19/2","19/3","19/4","19/5","19/6","19/7","19/8","20","20/1","20/2","20/3","20/4","21","21/1","21/2","21/3","21/4","22","22/9","23","23/2","23/4","24","24/1","24/2","24/3","24/A","25","25/1","25/10","25/2","25/4","25/5","25/6","25/7","25/8","25/9","26","26/1","26/6","27","27/2","28","28/1","29","29/2","29/3","29/4","30","30/1","30/2","30/3","31","31/1","31/3","32/A","33","34","34/1","34/11","34/2","34/3","35","35/1","35/2","35/4","36","36/1","36/A","37","37/1","37/2","38","38/1","38/2","39/1","39/2","39/3","39/4","40","40/1","41","41/2","42","43","44","45","45/1","45/10","45/11","45/12","45/13","45/14","45/15","45/16","45/17","45/2","45/3","45/6","45/7","45/8","45/9","46","47","47/2","49","49/1","50","51","51/1","51/2","52","53","54","55/7","66","109","122","190/8","412"], {minChars:1, mustMatch:true}).result(function(event, result, formatted) { var found=false; for(var index=0; index<HChouses.length; index++) //HChouses is the same array used for init, but each entry is paired with a database ID. if(HChouses[index][0]==result) { found=true; HChouseId=HChouses[index][1]; $("#row_house .button-finish").click(function() { QueryServer("HouseConnect","FillData",true,HChouseId); //this performs an AJAX request }); break; } if(!found) $("#row_house .button-finish").unbind("click"); }); Each time I start typing (say I press the "1" button), the text appears and gets deleted instantly. Rarely at all after repeated presses I get the list (although much shorter than it should be) But if after that I press the second digit, the whole thing disappears again. P.S. I use Firefox 3.6.3 for development.

    Read the article

  • Clock running too fast

    - by sBlatt
    I'm currently (for some days now) having the problem, that my Ubuntu clock runs to fast. and by to fast I mean like: last time I adjusted it was at 4 PM, now (10:25 PM) it shows 10:57 PM ! Any ideas how to fix that? Could it have something to do with handbrake? (I'm currently ripping my DVD collection, so handbrake is always running). My System: Ubuntu 10.4, all updates, handbrake from getdeb (0.9.4 I think), Intel Core2Quad, 4 GB Ram, NVidia GTX 260 (195.36.24 according to nvidia-settings) thx for any help Edit: dmesg: http://pastebin.com/VAanad5E /proc/interrupts: http://pastebin.com/VAZLAHzR cmdline: BOOT_IMAGE=/boot/vmlinuz-2.6.32-24-generic root=UUID=082d6800-413b-43d7-b4d1-b96b0d774f32 ro quiet splash

    Read the article

  • How do I pass a javascript parameter to an asp.net MVCmodel from within a View?

    - by Josh
    Hi everyone! I am having an issue trying to access a list property on a model from within a javascript. My basic situation is this: I have an ArticleController and an ArticleViewModel. An Article has a number of properties, one of which is Text, which is just a string that contains the contents of the article. The ArticleViewModel contains a Pages property, which is just a List of Strings. When the ArticleViewModel constructor is called, I populate the Pages list by dividing up the article text based on some delimeters. I have a View which inherits the ArticleViewModel type. What I want to do is only display one page at a time, and then when the user clicks a page number (from a list at the bottom of the article), I want to use javascript to load that page into the #dynamicContent div. The problem: I can't seem to pass a parameter to the Model.Pages property from within javascript... Is this possible? I get an error stating, "Expression Expected" when I try what I have below. I don't want to have to worry about AJAX calls or anything like that since I already have the entire article... I just need a way to access each individual page from within the javascript function. Alternatively, if there is a better solution for "paginating" an article so that I can load each articlePage without having to refresh the entire html page, I would certainly be open to that as well. Any help would be much appreciated!! Thanks for your time! ArticleView Code: Script at the top of the view: function loadPage(pageNumber) { try { alert(pageNumber); $('#dynamicContent').html('<%=Model.Pages(' + pageNumber + ') %>'); } catch (e) { alert('in here'); alert(e.description); } } HTML for view: [...] <div id="articleBody"> <div id="dynamicContent"> <%=Model.Pages(0)%> </div> </div> [...] Page Links at bottom of page: [...] <div> <ul style="display:block"> <li style="display:inline"> <a href="#articleTitle" onclick="loadPage(0)"> 1 </a> </li> <li style="display:inline"> <a href="#articleTitle" onclick="loadPage(1)"> 2 </a> </li> </ul> </div>

    Read the article

  • entering data in sql database through asp

    - by sushant
    pass=session("password") Set objIns=server.CreateObject("adodb.connection") objIns.Open session("Psrconnect") inspass="Insert into passwords(pass) values ('&pass&')" objIns.Execute(inspass) i dont know what should be the syntax to pass the value stored in the variable. with this syntax, the value entered in the database is &pass&. can anyone plz help me out?

    Read the article

  • How to pass multiple PHP variables to a jQuery function?

    - by jcpeden
    I'm working on a Wordpress plugin. I need to pass plugin directories (that can change depending on an individual's installation) to a jquery function. What is the best way of doing this? The version of the plugin that I can to work on had included all the javascript in the PHP file so the functions were parsed along with the rest of the content before being rendered in a browser. I'm looking at AJAX but I think it might be more complicated than I need. I can get away with just two variables in this case (directories, nothing set by the user). As I've read its good practice, I'm trying to keep the js and php separate. When the plugin initializes, it call the js file: //Wordpress calls the .js when the plugin loads wp_enqueue_script( 'wp-backitup-funtions', plugin_dir_url( __FILE__ ) . 'js/wp-backitup.js', array( 'jquery' ) ); Then I'm in the .js file and need to figure out how to generate the following variables: dir = '<?php echo content_url() ."/plugins"; ?>'; dir = '<?php echo content_url() ."/themes"; ?>'; dir = '<?php echo content_url() ."/uploads"; ?>'; And run the parse the following requests: xmlhttp.open("POST","<?php echo plugins_url() .'/wp-backitup/includes/wp-backitup-restore.php'); ?>",true); xmlhttp.open("POST","<?php echo plugins_url() .'/wp-backitup/includes/wp-backitup-start.php'); ?>",true); xmlhttp.open("POST","<?php echo plugins_url() .'/wp-backitup/wp-backitup-directory.php'); ?>",true); xmlhttp.open("POST","<?php echo plugins_url() .'/wp-backitup/wp-backitup-db.php'); ?>",true); window.location = "<?php echo plugins_url() .'/wp-backitup/backitup-project.zip'); ?>"; xmlhttp.open("POST","<?php echo plugins_url() .'/wp-backitup/wp-backitup-delete.php'); ?>",true); Content URL and Plugins URL differ only by /plugins/ so if I was hard pressed, I would only really need to make a single PHP request and then bring this into the JS.

    Read the article

  • ????????!?Oracle DBA & Developer Day 2012? ????????

    - by OTN-J Master
    ?????!DBA & Developer Day ??????????????????????????????!????????????DBA & Developer Day ???????????????????????????????????????????????????????????????????????????????????? OTN ??????????????????? ???????????????????????????????????????????????????????????????????Oracle Database Cloud Service??????????????????????????????·?????????Michael Hichwa??????Oracle OpenWorld 2012 ????????????????????????????????????Oracle Database Cloud Service???????????????????????????????????????????????????????????????????????Pluggable Database(???????????)??????????????????????????? ????2?????????6????????????24???????????????????????? Oracle Database ???????? ???????(MAA) Oracle Database ???????? BIG DATA Oracle Fusion Middleware???????? Oracle Solaris OTN ?????????????????????????????????????? – ??????????????????????????????????????????????????????????????????????????????????????????????????????????????????????? (???????????????????????)??????SPARC T4-1????????????????????????????????????????????????????????????? ????????????????????????????????????????????????????????????????????????????????????????24?????????(??·??)??????????! ????????????????????????????????????? (????: ?????????????????????????????????????????????)  

    Read the article

  • How do you pass user credentials from WebClient to a WCF REST service?

    - by Alex
    I am trying to expose a WCT REST service and only users with valid username and password would be able to access it. The username and password are stored in a SQL database. Here is the service contract: public interface IDataService { [OperationContract] [WebGet(ResponseFormat = WebMessageFormat.Json)] byte[] GetData(double startTime, double endTime); } Here is the WCF configuration: <bindings> <webHttpBinding> <binding name="SecureBinding"> <security mode="Transport"> <transport clientCredentialType="Basic"/> </security> </binding> </webHttpBinding> </bindings> <behaviors> <serviceBehaviors> <behavior name="DataServiceBehavior"> <serviceMetadata httpGetEnabled="true"/> <serviceCredentials> <userNameAuthentication userNamePasswordValidationMode="Custom" customUserNamePasswordValidatorType= "CustomValidator, WCFHost" /> </serviceCredentials> </behavior> </serviceBehaviors> </behaviors> <services> <service behaviorConfiguration="DataServiceBehavior" name="DataService"> <endpoint address="" binding="webHttpBinding" bindingConfiguration="SecureBinding" contract="IDataService" /> </service> </services> I am accessing the service via the WebClient class within a Silverlight application. However, I have not been able to figure out how to pass the user credentials to the service. I tried various values for client.Credentials but none of them seems to trigger the code in my custom validator. I am getting the following error: The underlying connection was closed: An unexpected error occurred on a send. Here is some sample code I have tried: WebClient client = new WebClient(); client.Credentials = new NetworkCredential("name", "password", "domain"); client.OpenReadCompleted += new OpenReadCompletedEventHandler(GetData); client.OpenReadAsync(new Uri(uriString)); If I set the security mode to None, the whole thing works. I also tried other clientCredentialType values and none of them worked. I also self-hosted the WCF service to eliminate the issues related to IIS trying to authenticate a user before the service gets a chance. Any comment on what the underlying issues may be would be much appreciated. Thanks. Update: Thanks to Mehmet's excellent suggestions. Here is the tracing configuration I had: <system.diagnostics> <sources> <source name="System.ServiceModel" switchValue="Information, ActivityTracing" propagateActivity="true"> <listeners> <add name="xml" /> </listeners> </source> <source name="System.IdentityModel" switchValue="Information, ActivityTracing" propagateActivity="true"> <listeners> <add name="xml" /> </listeners> </source> </sources> <sharedListeners> <add name="xml" type="System.Diagnostics.XmlWriterTraceListener" initializeData="c:\Traces.svclog" /> </sharedListeners> </system.diagnostics> But I did not see any message coming from my Silverlight client. As for https vs http, I used https as follows: string baseAddress = "https://localhost:6600/"; _webServiceHost = new WebServiceHost(typeof(DataServices), new Uri(baseAddress)); _webServiceHost.Open(); However, I did not configure any SSL certificate. Is this the problem?

    Read the article

  • Why is this RMagick call generating a segmentation fault?

    - by Grant Heaslip
    I've been banging my head against the wall for the better part of an hour trying to figure out what's going wrong here, and I'm sure (or rather hoping) it's something fairly obvious that I'm overlooking. I'm using Ruby 1.9.1, Sinatra 1.0, and RMagick 2.13.1. ImageMagick and RMagick are correctly installed and functional—I've successfully manipulated and saved images from irb. The relevant part of the params array (formatting changes for the sake of readability): {"admin_user_new_image_file"=> { :filename=>"freddie-on-shetland-pony.png", :type=>"image/png", :name=>"admin_user_new_image_file", :tempfile=>#<File:/var/folders/a7/a7pO5jMcGLCww9XBGRvWfE+++TI/-Tmp-/RackMultipart20100514-20700-o2tkqu-0>, :head=>"Content-Disposition: form-data; name=\"admin_user_new_image_file\"; filename=\"freddie-on-shetland-pony.png\"\r\nContent-Type: image/png\r\n" } } The relevant code: post "/admin/user/:account_name/image/new/" do if params[:admin_user_new_image_file][:tempfile] thumbnail = Magick::Image.read("png:"+params[:admin_user_new_image_file][:tempfile].path).first end end The error (line 229 is the line starting with "thumbnail = ": config.ru:229: [BUG] Segmentation fault ruby 1.9.1p376 (2009-12-07 revision 26041) [i386-darwin10.3.0] -- control frame ---------- c:0042 p:---- s:0196 b:0196 l:000195 d:000195 CFUNC :read c:0041 p:0121 s:0192 b:0192 l:001ab8 d:000191 LAMBDA config.ru:229 c:0040 p:---- s:0189 b:0189 l:000188 d:000188 FINISH c:0039 p:---- s:0187 b:0187 l:000186 d:000186 CFUNC :call c:0038 p:0018 s:0184 b:0184 l:001d78 d:000183 BLOCK /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:865 c:0037 p:---- s:0182 b:0182 l:000181 d:000181 FINISH c:0036 p:---- s:0180 b:0180 l:000179 d:000179 CFUNC :instance_eval c:0035 p:0016 s:0177 b:0175 l:000174 d:000174 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:521 c:0034 p:0024 s:0171 b:0171 l:000148 d:000170 BLOCK /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:500 c:0033 p:---- s:0169 b:0169 l:000168 d:000168 FINISH c:0032 p:---- s:0167 b:0167 l:000166 d:000166 CFUNC :catch c:0031 p:0140 s:0163 b:0163 l:000148 d:000162 BLOCK /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:497 c:0030 p:---- s:0154 b:0154 l:000153 d:000153 FINISH c:0029 p:---- s:0152 b:0152 l:000151 d:000151 CFUNC :each c:0028 p:0073 s:0149 b:0149 l:000148 d:000148 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:476 c:0027 p:0076 s:0141 b:0141 l:000140 d:000140 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:601 c:0026 p:0009 s:0137 b:0137 l:000138 d:000136 BLOCK /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:411 c:0025 p:---- s:0135 b:0135 l:000134 d:000134 FINISH c:0024 p:---- s:0133 b:0133 l:000132 d:000132 CFUNC :instance_eval c:0023 p:0012 s:0130 b:0130 l:000121 d:000129 BLOCK /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:566 c:0022 p:---- s:0128 b:0128 l:000127 d:000127 FINISH c:0021 p:---- s:0126 b:0126 l:000125 d:000125 CFUNC :catch c:0020 p:0013 s:0122 b:0122 l:000121 d:000121 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:566 c:0019 p:0098 s:0115 b:0115 l:000138 d:000138 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:411 c:0018 p:0019 s:0108 b:0108 l:000107 d:000107 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:399 c:0017 p:0014 s:0104 b:0104 l:000103 d:000103 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/showexceptions.rb:24 c:0016 p:0150 s:0098 b:0098 l:000097 d:000097 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/methodoverride.rb:24 c:0015 p:0031 s:0092 b:0092 l:000091 d:000091 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/commonlogger.rb:18 c:0014 p:0018 s:0084 b:0084 l:002080 d:000083 BLOCK /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:979 c:0013 p:0032 s:0082 b:0082 l:000081 d:000081 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:1005 c:0012 p:0011 s:0078 b:0078 l:002080 d:002080 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:979 c:0011 p:0100 s:0074 b:0074 l:000ff0 d:000ff0 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/lint.rb:47 c:0010 p:0022 s:0068 b:0068 l:000067 d:000067 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/lint.rb:35 c:0009 p:0014 s:0064 b:0064 l:000063 d:000063 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/showexceptions.rb:24 c:0008 p:0031 s:0058 b:0058 l:000057 d:000057 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/commonlogger.rb:18 c:0007 p:0014 s:0050 b:0050 l:000049 d:000049 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/content_length.rb:13 c:0006 p:0320 s:0042 b:0042 l:000041 d:000041 METHOD /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/handler/webrick.rb:48 c:0005 p:0256 s:0030 b:0030 l:000029 d:000029 METHOD /usr/local/lib/ruby/1.9.1/webrick/httpserver.rb:111 c:0004 p:0382 s:0020 b:0020 l:000019 d:000019 METHOD /usr/local/lib/ruby/1.9.1/webrick/httpserver.rb:70 c:0003 p:0123 s:0009 b:0009 l:000bc8 d:000008 BLOCK /usr/local/lib/ruby/1.9.1/webrick/server.rb:183 c:0002 p:---- s:0004 b:0004 l:000003 d:000003 FINISH c:0001 p:---- s:0002 b:0002 l:000001 d:000001 TOP --------------------------- -- Ruby level backtrace information----------------------------------------- config.ru:229:in `read' config.ru:229:in `block (2 levels) in <main>' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:865:in `call' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:865:in `block in route' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:521:in `instance_eval' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:521:in `route_eval' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:500:in `block (2 levels) in route!' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:497:in `catch' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:497:in `block in route!' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:476:in `each' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:476:in `route!' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:601:in `dispatch!' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:411:in `block in call!' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:566:in `instance_eval' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:566:in `block in invoke' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:566:in `catch' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:566:in `invoke' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:411:in `call!' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:399:in `call' /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/showexceptions.rb:24:in `call' /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/methodoverride.rb:24:in `call' /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/commonlogger.rb:18:in `call' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:979:in `block in call' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:1005:in `synchronize' /usr/local/lib/ruby/gems/1.9.1/gems/sinatra-1.0/lib/sinatra/base.rb:979:in `call' /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/lint.rb:47:in `_call' /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/lint.rb:35:in `call' /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/showexceptions.rb:24:in `call' /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/commonlogger.rb:18:in `call' /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/content_length.rb:13:in `call' /usr/local/lib/ruby/gems/1.9.1/gems/rack-1.1.0/lib/rack/handler/webrick.rb:48:in `service' /usr/local/lib/ruby/1.9.1/webrick/httpserver.rb:111:in `service' /usr/local/lib/ruby/1.9.1/webrick/httpserver.rb:70:in `run' /usr/local/lib/ruby/1.9.1/webrick/server.rb:183:in `block in start_thread' -- C level backtrace information ------------------------------------------- 0x10010cd8d 0 libruby.dylib 0x000000010010cd8d rb_vm_bugreport + 77 0x10002b184 1 libruby.dylib 0x000000010002b184 report_bug + 260 0x10002b318 2 libruby.dylib 0x000000010002b318 rb_bug + 200 0x1000b7124 3 libruby.dylib 0x00000001000b7124 sigsegv + 132 0x7fff8301c80a 4 libSystem.B.dylib 0x00007fff8301c80a _sigtramp + 26 0x1032313ac 5 libMagickCore.3.dylib 0x00000001032313ac Splay + 300 0x103119245 6 libMagickCore.3.dylib 0x0000000103119245 AcquirePixelCache + 325 0x1031cb317 7 libMagickCore.3.dylib 0x00000001031cb317 AcquireImage + 375 0x10333035b 8 libMagickCore.3.dylib 0x000000010333035b ReadPNGImage + 155 0x1031418fd 9 libMagickCore.3.dylib 0x00000001031418fd ReadImage + 2221 0x101f1b72b 10 RMagick2.bundle 0x0000000101f1b72b rd_image + 339 0x101f1b59b 11 RMagick2.bundle 0x0000000101f1b59b Image_read + 36 0x1000fd0e4 12 libruby.dylib 0x00000001000fd0e4 vm_call_cfunc + 340 0x1000fe9b0 13 libruby.dylib 0x00000001000fe9b0 vm_call_method + 896 0x1000ff8fc 14 libruby.dylib 0x00000001000ff8fc vm_exec_core + 3180 0x100104b93 15 libruby.dylib 0x0000000100104b93 vm_exec + 1203 0x100106643 16 libruby.dylib 0x0000000100106643 rb_vm_invoke_proc + 691 0x100106ccd 17 libruby.dylib 0x0000000100106ccd vm_call0 + 1085 0x1000317c6 18 libruby.dylib 0x00000001000317c6 rb_method_call + 406 0x1000fd0e4 19 libruby.dylib 0x00000001000fd0e4 vm_call_cfunc + 340 0x1000fe9b0 20 libruby.dylib 0x00000001000fe9b0 vm_call_method + 896 0x1000ff8fc 21 libruby.dylib 0x00000001000ff8fc vm_exec_core + 3180 0x100104b93 22 libruby.dylib 0x0000000100104b93 vm_exec + 1203 0x100105ce6 23 libruby.dylib 0x0000000100105ce6 yield_under + 710 0x100106188 24 libruby.dylib 0x0000000100106188 specific_eval + 72 0x1000fd0e4 25 libruby.dylib 0x00000001000fd0e4 vm_call_cfunc + 340 0x1000fe9b0 26 libruby.dylib 0x00000001000fe9b0 vm_call_method + 896 0x1000ff8fc 27 libruby.dylib 0x00000001000ff8fc vm_exec_core + 3180 0x100104b93 28 libruby.dylib 0x0000000100104b93 vm_exec + 1203 0x10010b6bf 29 libruby.dylib 0x000000010010b6bf rb_f_catch + 639 0x1000fd0e4 30 libruby.dylib 0x00000001000fd0e4 vm_call_cfunc + 340 0x1000fe9b0 31 libruby.dylib 0x00000001000fe9b0 vm_call_method + 896 0x1000ff8fc 32 libruby.dylib 0x00000001000ff8fc vm_exec_core + 3180 0x100104b93 33 libruby.dylib 0x0000000100104b93 vm_exec + 1203 0x10010aac9 34 libruby.dylib 0x000000010010aac9 rb_yield + 505 0x100007902 35 libruby.dylib 0x0000000100007902 rb_ary_each + 82 0x1000fd0e4 36 libruby.dylib 0x00000001000fd0e4 vm_call_cfunc + 340 0x1000fe9b0 37 libruby.dylib 0x00000001000fe9b0 vm_call_method + 896 0x1000ff8fc 38 libruby.dylib 0x00000001000ff8fc vm_exec_core + 3180 0x100104b93 39 libruby.dylib 0x0000000100104b93 vm_exec + 1203 0x100105ce6 40 libruby.dylib 0x0000000100105ce6 yield_under + 710 0x100106188 41 libruby.dylib 0x0000000100106188 specific_eval + 72 0x1000fd0e4 42 libruby.dylib 0x00000001000fd0e4 vm_call_cfunc + 340 0x1000fe9b0 43 libruby.dylib 0x00000001000fe9b0 vm_call_method + 896 0x1000ff8fc 44 libruby.dylib 0x00000001000ff8fc vm_exec_core + 3180 0x100104b93 45 libruby.dylib 0x0000000100104b93 vm_exec + 1203 0x10010b6bf 46 libruby.dylib 0x000000010010b6bf rb_f_catch + 639 0x1000fd0e4 47 libruby.dylib 0x00000001000fd0e4 vm_call_cfunc + 340 0x1000fe9b0 48 libruby.dylib 0x00000001000fe9b0 vm_call_method + 896 0x1000ff8fc 49 libruby.dylib 0x00000001000ff8fc vm_exec_core + 3180 0x100104b93 50 libruby.dylib 0x0000000100104b93 vm_exec + 1203 0x100106643 51 libruby.dylib 0x0000000100106643 rb_vm_invoke_proc + 691 0x100111803 52 libruby.dylib 0x0000000100111803 thread_start_func_2 + 835 0x100111921 53 libruby.dylib 0x0000000100111921 thread_start_func_1 + 17 0x7fff82ff58b6 54 libSystem.B.dylib 0x00007fff82ff58b6 _pthread_start + 331 0x7fff82ff5769 55 libSystem.B.dylib 0x00007fff82ff5769 thread_start + 13 [NOTE] You may encounter a bug of Ruby interpreter. Bug reports are welcome. For details: http://www.ruby-lang.org/bugreport.html Abort trap Anyone have any idea what's going on? Thanks!

    Read the article

  • Is it possible to create a timer in jscript that you can manually change without it being affected by timezones?

    - by Lixorp
    is it possible to create a timer where I can manually set the hours each day to a set number of hours but still remains accurate? For example; if I set the countdown for 5 hours at 2pm I want the timer to stop as soon as it hits 7pm. Also, when I set the timer for 5 hours I would like everyone in the world to see it countdown from 5 hours, no matter what the time is in their country. In the format: days hours minutes seconds. The reason I want to do this is for a streamer's website. He needs a flexible timer which can be manually changed and is the same worldwide for his viewers to know when he starts streaming. The current timer we're using at the moment; setInterval(function(){ var currentTime = new Date(); if(currentTime.getHours() > 19){ var countdownHours = (24 - currentTime.getHours()) + 19; }else if(currentTime.getHours() < 19){ var countdownHours = 19 - currentTime.getHours(); }else{ var countdownHours = 0; } var countdownMins = 59 - currentTime.getMinutes(); var countdownSecs = 60 - currentTime.getSeconds(); $('#countdown-days h1').text('0'); $('#countdown-hours h1').text(countdownHours); $('#countdown-minutes h1').text(countdownMins); $('#countdown-seconds h1').text(countdownSecs); }, 1000); As you can tell it isn't ideal for what we need it for since it counts down to 7pm in the timezone you're in. Any help/examples would be greatly appreciated, Thank you in advance, Lixorp.

    Read the article

  • Java: Incompatible Types

    - by user2922081
    import java.text.*; import java.util.*; public class Proj3 { public static void main(String[]args){ // DecimalFormat df = new DecimalFormat("#0.00”); Scanner s = new Scanner(System.in); int TotalHours = 0; int TotalGrade = 0; System.out.print("How many courses did you take? "); int Courses = Integer.parseInt(s.nextLine()); System.out.println(""); int CourseNumber = Courses - (Courses - 1); while (Courses > 0){ System.out.print("Course (" + CourseNumber +"): How many hours? "); int Hours = Integer.parseInt(s.nextLine()); TotalHours = TotalHours + Hours; System.out.print("Course (" + CourseNumber +"): Letter grade? "); char Grade = s.nextLine().charAt(0); if (Grade == 'A'){ TotalGrade = TotalGrade + (4 * Hours); } if (Grade == 'B'){ TotalGrade = TotalGrade + (3 * Hours); } if (Grade == 'C'){ TotalGrade = TotalGrade + (2 * Hours); } if (Grade == 'D'){ TotalGrade = TotalGrade + (1 * Hours); } Courses = Courses - 1; CourseNumber = CourseNumber + 1; } Double GPA = TotalGrade / TotalHours; System.out.println(df.format(GPA)); } } This is for an assignment and I don't know how to fix my problem. The Double GPA = TotalGrade / ToutalHours; line is coming up with the Incompatible Types error. Also I'm supposed to include the DecimalFormat df = new DecimalFormat("#0.00”);line at the beginning of the main but its not working. Anything is very helpful. Thanks

    Read the article

  • Hard Disk DRDY error: is it a crash

    - by pranjal
    I am using IBM Thinkpad, 1.7GHz, 512 RAM with Linux Mint 9 installed. I have two partitions in addition to root. One of the partitions became read-only yesterday, after which I rebooted my system. It is extremely slow along with DRDY Error : Is my Hard disk crashed ? Error Log while booting. Differences between boot sector and its backup. failed command : READ DMA BMDMA : stat 0X25 ata 1.00 : status : { DRDY ERR } ata 1.00 : status :{ UNC } Buffer I/O error on logical device, logical block 65467 smartctl output for the partition: mint mint # smartctl -a /dev/sda1 smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: TOSHIBA MK4026GAX RoHS Serial Number: X5LY1623T Firmware Version: PA107E User Capacity: 40,007,761,920 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 6 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Thu Feb 17 06:48:25 2011 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 153) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 30) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 310 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 3968 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 40 7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 082 082 000 Old_age Always - 7257 10 Spin_Retry_Count 0x0033 179 100 030 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3484 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 489 193 Load_Cycle_Count 0x0032 064 064 000 Old_age Always - 367150 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 36 (Lifetime Min/Max 14/57) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 33 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 82 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 1 199 UDMA_CRC_Error_Count 0x0032 200 253 000 Old_age Always - 0 220 Disk_Shift 0x0002 100 100 000 Old_age Always - 101 222 Loaded_Hours 0x0032 085 085 000 Old_age Always - 6146 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0 224 Load_Friction 0x0022 100 100 000 Old_age Always - 0 226 Load-in_Time 0x0026 100 100 000 Old_age Always - 227 240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0 SMART Error Log Version: 1 ATA Error Count: 2371 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 2371 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:03:10.061 READ DMA f8 00 00 00 00 00 e0 00 00:03:10.061 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:03:10.053 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:03:10.053 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:03:10.053 READ NATIVE MAX ADDRESS Error 2370 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:03:03.328 READ DMA f8 00 00 00 00 00 e0 00 00:03:03.327 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:03:03.320 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:03:03.319 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:03:03.319 READ NATIVE MAX ADDRESS Error 2369 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:56.582 READ DMA f8 00 00 00 00 00 e0 00 00:02:56.582 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:56.574 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:56.574 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:56.574 READ NATIVE MAX ADDRESS Error 2368 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:49.809 READ DMA f8 00 00 00 00 00 e0 00 00:02:49.809 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:49.801 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:49.801 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:49.801 READ NATIVE MAX ADDRESS Error 2367 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:43.056 READ DMA f8 00 00 00 00 00 e0 00 00:02:43.056 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:43.048 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:43.048 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:43.047 READ NATIVE MAX ADDRESS SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Device does not support Selective Self Tests/Logging Do I need to get a new Hard Disk my PC ?

    Read the article

< Previous Page | 93 94 95 96 97 98 99 100 101 102 103 104  | Next Page >