Search Results

Search found 8997 results on 360 pages for 'apt cache'.

Page 98/360 | < Previous Page | 94 95 96 97 98 99 100 101 102 103 104 105  | Next Page >

  • External HDD USB 3.0 failure

    - by Philip
    [ 2560.376113] usb 9-1: new high-speed USB device number 2 using xhci_hcd [ 2560.376186] usb 9-1: Device not responding to set address. [ 2560.580136] usb 9-1: Device not responding to set address. [ 2560.784104] usb 9-1: device not accepting address 2, error -71 [ 2560.840127] hub 9-0:1.0: unable to enumerate USB device on port 1 [ 2561.080182] usb 10-1: new SuperSpeed USB device number 5 using xhci_hcd [ 2566.096163] usb 10-1: device descriptor read/8, error -110 [ 2566.200096] usb 10-1: new SuperSpeed USB device number 5 using xhci_hcd [ 2571.216175] usb 10-1: device descriptor read/8, error -110 [ 2571.376138] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2571.744174] usb 10-1: new SuperSpeed USB device number 7 using xhci_hcd [ 2576.760116] usb 10-1: device descriptor read/8, error -110 [ 2576.864074] usb 10-1: new SuperSpeed USB device number 7 using xhci_hcd [ 2581.880153] usb 10-1: device descriptor read/8, error -110 [ 2582.040123] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2582.224139] hub 9-0:1.0: unable to enumerate USB device on port 1 [ 2582.464177] usb 10-1: new SuperSpeed USB device number 9 using xhci_hcd [ 2587.480122] usb 10-1: device descriptor read/8, error -110 [ 2587.584079] usb 10-1: new SuperSpeed USB device number 9 using xhci_hcd [ 2592.600150] usb 10-1: device descriptor read/8, error -110 [ 2592.760134] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2593.128175] usb 10-1: new SuperSpeed USB device number 11 using xhci_hcd [ 2598.144183] usb 10-1: device descriptor read/8, error -110 [ 2598.248109] usb 10-1: new SuperSpeed USB device number 11 using xhci_hcd [ 2603.264171] usb 10-1: device descriptor read/8, error -110 [ 2603.480157] usb 10-1: new SuperSpeed USB device number 12 using xhci_hcd [ 2608.496162] usb 10-1: device descriptor read/8, error -110 [ 2608.600091] usb 10-1: new SuperSpeed USB device number 12 using xhci_hcd [ 2613.616166] usb 10-1: device descriptor read/8, error -110 [ 2613.832170] usb 10-1: new SuperSpeed USB device number 13 using xhci_hcd [ 2618.848135] usb 10-1: device descriptor read/8, error -110 [ 2618.952079] usb 10-1: new SuperSpeed USB device number 13 using xhci_hcd [ 2623.968155] usb 10-1: device descriptor read/8, error -110 [ 2624.184176] usb 10-1: new SuperSpeed USB device number 14 using xhci_hcd [ 2629.200124] usb 10-1: device descriptor read/8, error -110 [ 2629.304075] usb 10-1: new SuperSpeed USB device number 14 using xhci_hcd [ 2634.320172] usb 10-1: device descriptor read/8, error -110 [ 2634.424135] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2634.776186] usb 10-1: new SuperSpeed USB device number 15 using xhci_hcd [ 2639.792105] usb 10-1: device descriptor read/8, error -110 [ 2639.896090] usb 10-1: new SuperSpeed USB device number 15 using xhci_hcd [ 2644.912172] usb 10-1: device descriptor read/8, error -110 [ 2645.128174] usb 10-1: new SuperSpeed USB device number 16 using xhci_hcd [ 2650.144160] usb 10-1: device descriptor read/8, error -110 [ 2650.248062] usb 10-1: new SuperSpeed USB device number 16 using xhci_hcd [ 2655.264120] usb 10-1: device descriptor read/8, error -110 [ 2655.480182] usb 10-1: new SuperSpeed USB device number 17 using xhci_hcd [ 2660.496121] usb 10-1: device descriptor read/8, error -110 [ 2660.600086] usb 10-1: new SuperSpeed USB device number 17 using xhci_hcd [ 2665.616167] usb 10-1: device descriptor read/8, error -110 [ 2665.832177] usb 10-1: new SuperSpeed USB device number 18 using xhci_hcd [ 2670.848110] usb 10-1: device descriptor read/8, error -110 [ 2670.952066] usb 10-1: new SuperSpeed USB device number 18 using xhci_hcd [ 2675.968081] usb 10-1: device descriptor read/8, error -110 [ 2676.072124] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2786.104531] xhci_hcd 0000:02:00.0: remove, state 4 [ 2786.104546] usb usb10: USB disconnect, device number 1 [ 2786.104686] xHCI xhci_drop_endpoint called for root hub [ 2786.104692] xHCI xhci_check_bandwidth called for root hub [ 2786.104942] xhci_hcd 0000:02:00.0: USB bus 10 deregistered [ 2786.105054] xhci_hcd 0000:02:00.0: remove, state 4 [ 2786.105065] usb usb9: USB disconnect, device number 1 [ 2786.105176] xHCI xhci_drop_endpoint called for root hub [ 2786.105181] xHCI xhci_check_bandwidth called for root hub [ 2786.109787] xhci_hcd 0000:02:00.0: USB bus 9 deregistered [ 2786.110134] xhci_hcd 0000:02:00.0: PCI INT A disabled [ 2794.268445] pci 0000:02:00.0: [1b73:1000] type 0 class 0x000c03 [ 2794.268483] pci 0000:02:00.0: reg 10: [mem 0x00000000-0x0000ffff] [ 2794.268689] pci 0000:02:00.0: PME# supported from D0 D3hot [ 2794.268700] pci 0000:02:00.0: PME# disabled [ 2794.276383] pci 0000:02:00.0: BAR 0: assigned [mem 0xd7800000-0xd780ffff] [ 2794.276398] pci 0000:02:00.0: BAR 0: set to [mem 0xd7800000-0xd780ffff] (PCI address [0xd7800000-0xd780ffff]) [ 2794.276419] pci 0000:02:00.0: no hotplug settings from platform [ 2794.276658] xhci_hcd 0000:02:00.0: enabling device (0000 -> 0002) [ 2794.276675] xhci_hcd 0000:02:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 2794.276762] xhci_hcd 0000:02:00.0: setting latency timer to 64 [ 2794.276771] xhci_hcd 0000:02:00.0: xHCI Host Controller [ 2794.276913] xhci_hcd 0000:02:00.0: new USB bus registered, assigned bus number 9 [ 2794.395760] xhci_hcd 0000:02:00.0: irq 16, io mem 0xd7800000 [ 2794.396141] xHCI xhci_add_endpoint called for root hub [ 2794.396144] xHCI xhci_check_bandwidth called for root hub [ 2794.396195] hub 9-0:1.0: USB hub found [ 2794.396203] hub 9-0:1.0: 1 port detected [ 2794.396305] xhci_hcd 0000:02:00.0: xHCI Host Controller [ 2794.396371] xhci_hcd 0000:02:00.0: new USB bus registered, assigned bus number 10 [ 2794.396496] xHCI xhci_add_endpoint called for root hub [ 2794.396499] xHCI xhci_check_bandwidth called for root hub [ 2794.396547] hub 10-0:1.0: USB hub found [ 2794.396553] hub 10-0:1.0: 1 port detected [ 2798.004084] usb 1-3: new high-speed USB device number 8 using ehci_hcd [ 2798.140824] scsi21 : usb-storage 1-3:1.0 [ 2820.176116] usb 1-3: reset high-speed USB device number 8 using ehci_hcd [ 2824.000526] scsi 21:0:0:0: Direct-Access BUFFALO HD-PZU3 0001 PQ: 0 ANSI: 6 [ 2824.002263] sd 21:0:0:0: Attached scsi generic sg2 type 0 [ 2824.003617] sd 21:0:0:0: [sdb] 1953463728 512-byte logical blocks: (1.00 TB/931 GiB) [ 2824.005139] sd 21:0:0:0: [sdb] Write Protect is off [ 2824.005149] sd 21:0:0:0: [sdb] Mode Sense: 1f 00 00 08 [ 2824.009084] sd 21:0:0:0: [sdb] No Caching mode page present [ 2824.009094] sd 21:0:0:0: [sdb] Assuming drive cache: write through [ 2824.011944] sd 21:0:0:0: [sdb] No Caching mode page present [ 2824.011952] sd 21:0:0:0: [sdb] Assuming drive cache: write through [ 2824.049153] sdb: sdb1 [ 2824.051814] sd 21:0:0:0: [sdb] No Caching mode page present [ 2824.051821] sd 21:0:0:0: [sdb] Assuming drive cache: write through [ 2824.051825] sd 21:0:0:0: [sdb] Attached SCSI disk [ 2839.536624] usb 1-3: USB disconnect, device number 8 [ 2844.620178] usb 10-1: new SuperSpeed USB device number 2 using xhci_hcd [ 2844.640281] scsi22 : usb-storage 10-1:1.0 [ 2850.326545] scsi 22:0:0:0: Direct-Access BUFFALO HD-PZU3 0001 PQ: 0 ANSI: 6 [ 2850.327560] sd 22:0:0:0: Attached scsi generic sg2 type 0 [ 2850.329561] sd 22:0:0:0: [sdb] 1953463728 512-byte logical blocks: (1.00 TB/931 GiB) [ 2850.329889] sd 22:0:0:0: [sdb] Write Protect is off [ 2850.329897] sd 22:0:0:0: [sdb] Mode Sense: 1f 00 00 08 [ 2850.330223] sd 22:0:0:0: [sdb] No Caching mode page present [ 2850.330231] sd 22:0:0:0: [sdb] Assuming drive cache: write through [ 2850.331414] sd 22:0:0:0: [sdb] No Caching mode page present [ 2850.331423] sd 22:0:0:0: [sdb] Assuming drive cache: write through [ 2850.384116] usb 10-1: USB disconnect, device number 2 [ 2850.392050] sd 22:0:0:0: [sdb] Unhandled error code [ 2850.392056] sd 22:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2850.392061] sd 22:0:0:0: [sdb] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 2850.392074] end_request: I/O error, dev sdb, sector 0 [ 2850.392079] quiet_error: 70 callbacks suppressed [ 2850.392082] Buffer I/O error on device sdb, logical block 0 [ 2850.392194] ldm_validate_partition_table(): Disk read failed. [ 2850.392271] Dev sdb: unable to read RDB block 0 [ 2850.392377] sdb: unable to read partition table [ 2850.392581] sd 22:0:0:0: [sdb] READ CAPACITY failed [ 2850.392584] sd 22:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2850.392588] sd 22:0:0:0: [sdb] Sense not available. [ 2850.392613] sd 22:0:0:0: [sdb] Asking for cache data failed [ 2850.392617] sd 22:0:0:0: [sdb] Assuming drive cache: write through [ 2850.392621] sd 22:0:0:0: [sdb] Attached SCSI disk [ 2850.732182] usb 10-1: new SuperSpeed USB device number 3 using xhci_hcd [ 2850.752228] scsi23 : usb-storage 10-1:1.0 [ 2851.752709] scsi 23:0:0:0: Direct-Access BUFFALO HD-PZU3 0001 PQ: 0 ANSI: 6 [ 2851.754481] sd 23:0:0:0: Attached scsi generic sg2 type 0 [ 2851.756576] sd 23:0:0:0: [sdb] 1953463728 512-byte logical blocks: (1.00 TB/931 GiB) [ 2851.758426] sd 23:0:0:0: [sdb] Write Protect is off [ 2851.758436] sd 23:0:0:0: [sdb] Mode Sense: 1f 00 00 08 [ 2851.758779] sd 23:0:0:0: [sdb] No Caching mode page present [ 2851.758787] sd 23:0:0:0: [sdb] Assuming drive cache: write through [ 2851.759968] sd 23:0:0:0: [sdb] No Caching mode page present [ 2851.759977] sd 23:0:0:0: [sdb] Assuming drive cache: write through [ 2851.817710] sdb: sdb1 [ 2851.820562] sd 23:0:0:0: [sdb] No Caching mode page present [ 2851.820568] sd 23:0:0:0: [sdb] Assuming drive cache: write through [ 2851.820572] sd 23:0:0:0: [sdb] Attached SCSI disk [ 2852.060352] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.076533] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.076538] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.196329] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.212593] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.212599] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.456290] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.472402] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.472408] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.624304] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.640531] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.640536] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.772296] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.788536] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.788541] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.920349] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.936536] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.936540] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2853.072287] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2853.088565] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2853.088570] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.176339] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.192561] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.192567] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.320349] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.336526] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.336531] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.468344] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.484551] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.484556] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.612349] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.628540] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.628545] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.756350] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.772528] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.772533] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.848116] usb 10-1: USB disconnect, device number 3 [ 2884.851493] scsi 23:0:0:0: [sdb] killing request [ 2884.851501] scsi 23:0:0:0: [sdb] killing request [ 2884.851699] scsi 23:0:0:0: [sdb] Unhandled error code [ 2884.851702] scsi 23:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2884.851708] scsi 23:0:0:0: [sdb] CDB: Read(10): 28 00 00 5f 2b ee 00 00 3e 00 [ 2884.851721] end_request: I/O error, dev sdb, sector 6237166 [ 2884.851726] Buffer I/O error on device sdb1, logical block 6237102 [ 2884.851730] Buffer I/O error on device sdb1, logical block 6237103 [ 2884.851738] Buffer I/O error on device sdb1, logical block 6237104 [ 2884.851741] Buffer I/O error on device sdb1, logical block 6237105 [ 2884.851744] Buffer I/O error on device sdb1, logical block 6237106 [ 2884.851747] Buffer I/O error on device sdb1, logical block 6237107 [ 2884.851750] Buffer I/O error on device sdb1, logical block 6237108 [ 2884.851753] Buffer I/O error on device sdb1, logical block 6237109 [ 2884.851757] Buffer I/O error on device sdb1, logical block 6237110 [ 2884.851807] scsi 23:0:0:0: [sdb] Unhandled error code [ 2884.851810] scsi 23:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2884.851813] scsi 23:0:0:0: [sdb] CDB: Read(10): 28 00 00 5f 2c 2c 00 00 3e 00 [ 2884.851824] end_request: I/O error, dev sdb, sector 6237228 [ 2885.168190] usb 10-1: new SuperSpeed USB device number 4 using xhci_hcd [ 2885.188268] scsi24 : usb-storage 10-1:1.0 Please help me with my problem. I got this after running dmesg.

    Read the article

  • SQL SERVER – Identify Most Resource Intensive Queries – SQL in Sixty Seconds #028 – Video

    - by pinaldave
    During performance tuning conversation the very first question people often ask is what are the queries offending the server or in another word let us identify the queries which are the most resource intensive. The resources are often described as either Memory, CPU or IO. When we talk about the queries the same is applicable for them as well. The query which is doing lots of reads or writes are for sure resource intensive as well query which are taking maximum CPU time. Performance tuning is a very deep subject and we all have our own preference regarding what should be the first step to tuning and what should be looked with the salt of grain. Though there is no denying that a query which uses more resources than what it should be using for sure require tuning. There are many ways to do identify query using intense resources (e.g. Extended events etc) but in this one we will go by simple DMV. There is a small gotcha we all have to remember about usage of DMV is that it only brings back results from existing cache. So if you have a query which is very resource intensive but is not cached or if you have explicitly removed the query from the cache it will be not part of the result returned by this DMV. It is quite possible that a query is aged and removed from the cache if your cache is not huge. If your cache is large you may want to be careful in running this query during business hours as this query itself can be resource intensive. Get Script to identify resource intensive query from Here Related Tips in SQL in Sixty Seconds: SQL SERVER – Find Most Expensive Queries Using DMV Simple Example to Configure Resource Governor – Introduction to Resource Governor SQL SERVER – DMV – sys.dm_exec_query_optimizer_info – Statistics of Optimizer SQL SERVER – Wait Stats – Wait Types – Wait Queues – Day 0 of 28 Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: Database, Pinal Dave, PostADay, SQL, SQL Authority, SQL in Sixty Seconds, SQL Query, SQL Scripts, SQL Server, SQL Server Management Studio, SQL Tips and Tricks, T SQL, Technology, Video Tagged: Excel

    Read the article

  • First round playing with Memcached

    - by Shaun
    To be honest I have not been very interested in the caching before I’m going to a project which would be using the multi-site deployment and high connection and concurrency and very sensitive to the user experience. That means we must cache the output data for better performance. After looked for the Internet I finally focused on the Memcached. What’s the Memcached? I think the description on its main site gives us a very good and simple explanation. Free & open source, high-performance, distributed memory object caching system, generic in nature, but intended for use in speeding up dynamic web applications by alleviating database load. Memcached is an in-memory key-value store for small chunks of arbitrary data (strings, objects) from results of database calls, API calls, or page rendering. Memcached is simple yet powerful. Its simple design promotes quick deployment, ease of development, and solves many problems facing large data caches. Its API is available for most popular languages. The original Memcached was built on *nix system are is being widely used in the PHP world. Although it’s not a problem to use the Memcached installed on *nix system there are some windows version available fortunately. Since we are WISC (Windows – IIS – SQL Server – C#, which on the opposite of LAMP) it would be much easier for us to use the Memcached on Windows rather than *nix. I’m using the Memcached Win X64 version provided by NorthScale. There are also the x86 version and other operation system version.   Install Memcached Unpack the Memcached file to a folder on the machine you want it to be installed, we can see that there are only 3 files and the main file should be the “memcached.exe”. Memcached would be run on the server as a service. To install the service just open a command windows and navigate to the folder which contains the “memcached.exe”, let’s say “C:\Memcached\”, and then type “memcached.exe -d install”. If you are using Windows Vista and Windows 7 system please be execute the command through the administrator role. Right-click the command item in the start menu and use “Run as Administrator”, otherwise the Memcached would not be able to be installed successfully. Once installed successful we can type “memcached.exe -d start” to launch the service. Now it’s ready to be used. The default port of Memcached is 11211 but you can change it through the command argument. You can find the help by typing “memcached -h”.   Using Memcached Memcahed has many good and ready-to-use providers for vary program language. After compared and reviewed I chose the Memcached Providers. It’s built based on another 3rd party Memcached client named enyim.com Memcached Client. The Memcached Providers is very simple to set/get the cached objects through the Memcached servers and easy to be configured through the application configuration file (aka web.config and app.config). Let’s create a console application for the demonstration and add the 3 DLL files from the package of the Memcached Providers to the project reference. Then we need to add the configuration for the Memcached server. Create an App.config file and firstly add the section on top of it. Here we need three sections: the section for Memcached Providers, for enyim.com Memcached client and the log4net. 1: <configSections> 2: <section name="cacheProvider" 3: type="MemcachedProviders.Cache.CacheProviderSection, MemcachedProviders" 4: allowDefinition="MachineToApplication" 5: restartOnExternalChanges="true"/> 6: <sectionGroup name="enyim.com"> 7: <section name="memcached" 8: type="Enyim.Caching.Configuration.MemcachedClientSection, Enyim.Caching"/> 9: </sectionGroup> 10: <section name="log4net" 11: type="log4net.Config.Log4NetConfigurationSectionHandler,log4net"/> 12: </configSections> Then we will add the configuration for 3 of them in the App.config file. The Memcached server information would be defined under the enyim.com section since it will be responsible for connect to the Memcached server. Assuming I installed the Memcached on two servers with the default port, the configuration would be like this. 1: <enyim.com> 2: <memcached> 3: <servers> 4: <!-- put your own server(s) here--> 5: <add address="192.168.0.149" port="11211"/> 6: <add address="10.10.20.67" port="11211"/> 7: </servers> 8: <socketPool minPoolSize="10" maxPoolSize="100" connectionTimeout="00:00:10" deadTimeout="00:02:00"/> 9: </memcached> 10: </enyim.com> Memcached supports the multi-deployment which means you can install the Memcached on the servers as many as you need. The protocol of the Memcached responsible for routing the cached objects into the proper server. So it’s very easy to scale-out your system by Memcached. And then define the Memcached Providers configuration. The defaultExpireTime indicates how long the objected cached in the Memcached would be expired, the default value is 2000 ms. 1: <cacheProvider defaultProvider="MemcachedCacheProvider"> 2: <providers> 3: <add name="MemcachedCacheProvider" 4: type="MemcachedProviders.Cache.MemcachedCacheProvider, MemcachedProviders" 5: keySuffix="_MySuffix_" 6: defaultExpireTime="2000"/> 7: </providers> 8: </cacheProvider> The last configuration would be the log4net. 1: <log4net> 2: <!-- Define some output appenders --> 3: <appender name="ConsoleAppender" type="log4net.Appender.ConsoleAppender"> 4: <layout type="log4net.Layout.PatternLayout"> 5: <conversionPattern value="%date [%thread] %-5level %logger [%property{NDC}] - %message%newline"/> 6: </layout> 7: </appender> 8: <!--<threshold value="OFF" />--> 9: <!-- Setup the root category, add the appenders and set the default priority --> 10: <root> 11: <priority value="WARN"/> 12: <appender-ref ref="ConsoleAppender"> 13: <filter type="log4net.Filter.LevelRangeFilter"> 14: <levelMin value="WARN"/> 15: <levelMax value="FATAL"/> 16: </filter> 17: </appender-ref> 18: </root> 19: </log4net>   Get, Set and Remove the Cached Objects Once we finished the configuration it would be very simple to consume the Memcached servers. The Memcached Providers gives us a static class named DistCache that can be used to operate the Memcached servers. Get<T>: Retrieve the cached object from the Memcached servers. If failed it will return null or the default value. Add: Add an object with a unique key into the Memcached servers. Assuming that we have an operation that retrieve the email from the name which is time consuming. This is the operation that should be cached. The method would be like this. I utilized Thread.Sleep to simulate the long-time operation. 1: static string GetEmailByNameSlowly(string name) 2: { 3: Thread.Sleep(2000); 4: return name + "@ethos.com.cn"; 5: } Then in the real retrieving method we will firstly check whether the name, email information had been searched previously and cached. If yes we will just return them from the Memcached, otherwise we will invoke the slowly method to retrieve it and then cached. 1: static string GetEmailByName(string name) 2: { 3: var email = DistCache.Get<string>(name); 4: if (string.IsNullOrEmpty(email)) 5: { 6: Console.WriteLine("==> The name/email not be in memcached so need slow loading. (name = {0})==>", name); 7: email = GetEmailByNameSlowly(name); 8: DistCache.Add(name, email); 9: } 10: else 11: { 12: Console.WriteLine("==> The name/email had been in memcached. (name = {0})==>", name); 13: } 14: return email; 15: } Finally let’s finished the calling method and execute. 1: static void Main(string[] args) 2: { 3: var name = string.Empty; 4: while (name != "q") 5: { 6: Console.Write("==> Please enter the name to find the email: "); 7: name = Console.ReadLine(); 8:  9: var email = GetEmailByName(name); 10: Console.WriteLine("==> The email of {0} is {1}.", name, email); 11: } 12: } The first time I entered “ziyanxu” it takes about 2 seconds to get the email since there’s nothing cached. But the next time I entered “ziyanxu” it returned very quickly from the Memcached.   Summary In this post I explained a bit on why we need cache, what’s Memcached and how to use it through the C# application. The example is fairly simple but hopefully demonstrated on how to use it. Memcached is very easy and simple to be used since it gives you the full opportunity to consider what, when and how to cache the objects. And when using Memcached you don’t need to consider the cache servers. The Memcached would be like a huge object pool in front of you. The next step I’m thinking now are: What kind of data should be cached? And how to determined the key? How to implement the cache as a layer on top of the business layer so that the application will not notice that the cache is there. How to implement the cache by AOP so that the business logic no need to consider the cache. I will investigate on them in the future and will share my thoughts and results.   Hope this helps, Shaun All documents and related graphics, codes are provided "AS IS" without warranty of any kind. Copyright © Shaun Ziyan Xu. This work is licensed under the Creative Commons License.

    Read the article

  • Here’s a Quick Alternative Way to Download Videos from YouTube

    - by Taylor Gibb
    More than 24 hours of video content are uploaded to the internet per minute. With so many videos being uploaded, there’s no doubt you’ve come across a video you want to keep. Read on to find out how you can download your favorite videos for offline viewing. This method of downloading YouTube videos, is different, in the sense that you are just retrieving a buffered version of the video from your browsers cache. While you could always do this manually, different browsers store the cache in different places, a much easier method would be to head over to the NirSoft site and download a copy of Video Cache View (choose the zipped version), which allows you to view all the videos in your cache and supports all major browsers. Note: The download link is quite far down the page, see screenshot below How To Properly Scan a Photograph (And Get An Even Better Image) The HTG Guide to Hiding Your Data in a TrueCrypt Hidden Volume Make Your Own Windows 8 Start Button with Zero Memory Usage

    Read the article

  • Can't Remove Logical Drive/Array from HP P400

    - by Myles
    This is my first post here. Thank you in advance for any assistance with this matter. I'm trying to remove a logical drive (logical drive 2) and an array (array "B") from my Smart Array P400. The host is a DL580 G5 running 64-bit Red Hat Enterprise Linux Server release 5.7 (Tikanga). I am unable to remove the array using either hpacucli or cpqacuxe. I believe it is because of "OS Status: LOCKED". The file system that lives on this array has been unmounted. I do not want to reboot the host. Is there some way to "release" this logical drive so I can remove the array? Note that I do not need to preserve the data on logical drive 2. I intend to physically remove the drives from the machine and replace them with larger drives. I'm using the cciss kernel module that ships with Red Hat 5.7. Here is some information pertaining to the host and the P400 configuration: [root@gort ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.7 (Tikanga) [root@gort ~]# uname -a Linux gort 2.6.18-274.el5 #1 SMP Fri Jul 8 17:36:59 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux [root@gort ~]# rpm -qa | egrep '^(hp|cpq)' cpqacuxe-9.30-15.0 hp-health-9.25-1551.7.rhel5 hpsmh-7.1.2-3 hpdiags-9.3.0-466 hponcfg-3.1.0-0 hp-snmp-agents-9.25-2384.8.rhel5 hpacucli-9.30-15.0 [root@gort ~]# hpacucli HP Array Configuration Utility CLI 9.30.15.0 Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console. => ctrl all show config detail Smart Array P400 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Cache Serial Number: PA82C0J9SVW34U RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware Revision: D Firmware Version: 7.22 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 128 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Unique Identifier: 600508B100184A395356573334550002 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 101 MB, /tmp 7.8 GB, /usr 3.9 GB, /usr/local 2.0 GB, /var 3.9 GB, / 2.0 GB, /local 113.2 GB OS Status: LOCKED Logical Drive Label: A0027AA78DEE Mirror Group 0: physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) Drive Type: Data Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM57RF40000983878FX Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 35 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM55VQC000098388524 Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 36 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Logical Drive: 2 Size: 546.8 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 256 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Completed Unique Identifier: 600508B100184A395356573334550003 Disk Name: /dev/cciss/c0d1 Mount Points: None OS Status: LOCKED Logical Drive Label: A5C9C6F81504 Drive Type: Data Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2H5PE00009802NK19 Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 37 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 1I:1:4 Port: 1I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM28YY400009750MKPJ Model: HP DG146ABAB4 Current Temperature (C): 31 Maximum Temperature (C): 36 PHY Count: 1 PHY Transfer Rate: 3.0Gbps physicaldrive 2I:1:5 Port: 2I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FGYV00009802N3GN Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 38 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 2I:1:6 Port: 2I Box: 1 Bay: 6 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM8AFAK00009920MMV1 Model: HP DG146BB976 Current Temperature (C): 31 Maximum Temperature (C): 41 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:7 Port: 2I Box: 1 Bay: 7 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FJQD00009801MSHQ Model: HP DG146ABAB4 Current Temperature (C): 29 Maximum Temperature (C): 39 PHY Count: 1 PHY Transfer Rate: Unknown

    Read the article

  • Apache 2.4.3 php-fpm mod_fast_cgi and mod_cache

    - by Anjia
    Did anybody successfully configured mod_cache in apache 2.4 with php-fpm and fastcgi? my cgi config: <IfModule mod_fastcgi.c> Alias /php5.fastcgi /var/www/fastcgi/php5.fastcgi AddHandler php-script .php FastCGIExternalServer /var/www/fastcgi/php5.fastcgi -socket /mnt/tmp/fast/php-fpm.sock -idle-timeout 1600 -pass-header Authorization Action php-script /php5.fastcgi virtual My php-fpm config is standard and I am loading mod_cache and mod_disk_cache in Apache. However the Apache does not seems to cache any content. The debug log file: Fri Sep 07 23:22:59.691333 2012] [cache:debug] [pid 35623:tid 123613201929984] mod_cache.c(161): [client 10.0.0.22:21938] AH00750: Adding CACHE_SAVE filter for /index.html [Fri Sep 07 23:22:59.691345 2012] [cache:debug] [pid 35623:tid 123613201929984] mod_cache.c(171): [client 10.0.0.22:21938] AH00751: Adding CACHE_REMOVE_URL filter for /index.html [Fri Sep 07 23:23:01.326598 2012] [cache:debug] [pid 35623:tid 123613185144576] cache_storage.c(626): [client 10.0.0.110:5414] AH00698: cache: Key for entity /index.html?(null) is `http://10.0.1.16:8080/index.html?`

    Read the article

  • Ubuntu software center not opening [closed]

    - by I'll sudeepdino008
    Ubuntu software center is not opening, when I type: software-center in the command line, the following errors are generated: (software-center:8570): Gtk-WARNING **: Theme parsing error: gtk.css:227:31: Failed to import: Error opening file: No such file or directory 2012-09-30 17:00:58,068 - softwarecenter.ui.gtk3.app - INFO - setting up proxy 'http://10.3.100.212:8080/' 2012-09-30 17:00:58,071 - softwarecenter.db.database - INFO - open() database: path=None use_axi=True use_agent=True 2012-09-30 17:00:58,327 - softwarecenter.backend.reviews - WARNING - Could not get usefulness from server, no username in config file 2012-09-30 17:00:58,428 - softwarecenter.ui.gtk3.app - INFO - show_available_packages: search_text is '', app is None. 2012-09-30 17:00:58,433 - softwarecenter.db.pkginfo_impl.aptcache - INFO - aptcache.open() Traceback (most recent call last): File "/usr/share/software-center/softwarecenter/db/pkginfo_impl/aptcache.py", line 243, in open self._cache = apt.Cache(GtkMainIterationProgress()) File "/usr/lib/python2.7/dist-packages/apt/cache.py", line 102, in __init__ self.open(progress) File "/usr/lib/python2.7/dist-packages/apt/cache.py", line 145, in open self._cache = apt_pkg.Cache(progress) SystemError: E:Encountered a section with no Package: header, E:Problem with MergeList /var/lib/apt/lists/ppa.launchpad.net_webupd8team_themes_ubuntu_dists_precise_main_binary-i386_Packages, E:The package lists or status file could not be parsed or opened. 2012-09-30 17:01:00,130 - softwarecenter.db.enquire - ERROR - _get_estimate_nr_apps_and_nr_pkgs failed Traceback (most recent call last): File "/usr/share/software-center/softwarecenter/db/enquire.py", line 115, in _get_estimate_nr_apps_and_nr_pkgs tmp_matches = enquire.get_mset(0, len(self.db), None, xfilter) File "/usr/share/software-center/softwarecenter/db/appfilter.py", line 89, in __call__ if (not pkgname in self.cache and File "/usr/share/software-center/softwarecenter/db/pkginfo_impl/aptcache.py", line 263, in __contains__ return self._cache.__contains__(k) AttributeError: 'NoneType' object has no attribute '__contains__' Traceback (most recent call last): File "/usr/bin/software-center", line 176, in <module> app.run(args) File "/usr/share/software-center/softwarecenter/ui/gtk3/app.py", line 1422, in run self.show_available_packages(args) File "/usr/share/software-center/softwarecenter/ui/gtk3/app.py", line 1352, in show_available_packages self.view_manager.set_active_view(ViewPages.AVAILABLE) File "/usr/share/software-center/softwarecenter/ui/gtk3/session/viewmanager.py", line 154, in set_active_view view_widget.init_view() File "/usr/share/software-center/softwarecenter/ui/gtk3/panes/availablepane.py", line 171, in init_view self.apps_filter) File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 238, in __init__ self.build(desktopdir) File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 511, in build self._build_homepage_view() File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 271, in _build_homepage_view self._append_whats_new() File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 450, in _append_whats_new whats_new_cat = self._update_whats_new_content() File "/usr/share/software-center/softwarecenter/ui/gtk3/views/catview_gtk.py", line 439, in _update_whats_new_content docs = whats_new_cat.get_documents(self.db) File "/usr/share/software-center/softwarecenter/db/categories.py", line 124, in get_documents nonblocking_load=False) File "/usr/share/software-center/softwarecenter/db/enquire.py", line 317, in set_query self._blocking_perform_search() File "/usr/share/software-center/softwarecenter/db/enquire.py", line 212, in _blocking_perform_search matches = enquire.get_mset(0, self.limit, None, xfilter) File "/usr/share/software-center/softwarecenter/db/appfilter.py", line 89, in __call__ if (not pkgname in self.cache and File "/usr/share/software-center/softwarecenter/db/pkginfo_impl/aptcache.py", line 263, in __contains__ return self._cache.__contains__(k) AttributeError: 'NoneType' object has no attribute '__contains__'

    Read the article

  • Geocaching - World wide treasure hunt

    I'm not quite sure how I came across this topic but actually I find it absolutely interesting, challenging and most of all a great fun for the family and friends. The interesting part is for sure that you can follow other peoples treasures and their preferred locations where a cache might be hidden. Of course, it wont be easy to find a cache after all. Sometimes there are even 'mystery caches' which have either riddles, further instructions or little brain games for you in order to find the actual cache - that's the challenge. And last but not least, those caches are hidden outdoor. A great experience to explore nature either on your own, or your family especially with children, or as a treasure hunting pack with a couple of friends. What is geocaching? It's a high-tech outdoor treasure hunting game that's a great way to explore the world with friends, family or on your own. Participants use GPS-enabled devices to locate hidden containers called geocaches. There are over one million geocaches hidden around the world today, waiting for you to find them. Visit Geocaching.com to search for geocaches near you.(Source: Referral Email of geocaching.com) Checkout the Geocaching 101 for further details and information. They also provide a video channel on YouTube. Which equipment do I need? Any GPS-enabled device is sufficient to go onto the hunt. I'm going to start our geocaching experience equipped with my Samsung Galaxy Tab. Additionally, I installed a geocaching.com client called c:geo that hopefully assists me soon. Combined with a map app like Google Maps and a nice Compass app you should be fully equipped and ready to go. I guess, that even a car navigation system is perfect for that task. Later on, with more experience and demand for technology (or precision) it might be interesting to opt-in for a pure GPS device, like a Garmin or any other brand on the market. {loadposition content_adsense} What is a geocache and what does it contain? In its simplest form, a cache always contains a logbook or logsheet for you to log your find. Larger caches may contain a logbook and any number of items. These items turn the adventure into a true treasure hunt. You never know what the cache owner or visitors to the cache may have left for you to enjoy. Remember, if you take something, leave something of equal or greater value in return. It is recommended that items in a cache be individually packaged in a clear, zipped plastic bag to protect them from the elements. Finding your first geocache Well, first you have to have interest to pick up the challenge. Then you have to check out the Geocache directory on geocaching.com. They have recommendations for beginner's caches but you are free to choose any. Actually, we have a Mystery Cache very close to our base, and I guess that we are going for that one on our first trip. Anyway, there is a very informative guide on the website which should answer all your questions about starting your new outdoor adventure. For sure, it's going to be rewarding. Team up with friends and family Especially as a beginner there might be misunderstandings in handling the GPS coordinates, the compass, or the map, and even finding the container at the documented position isn't easy in the first place. Luckily, there are logbook reports online from other hunters, and most of the time there are even 'spoiler' images available. But also bear in mind, that a geocache might have been removed or is lost due to unconscious people or whatever other reasons. Don't be disappointed in case that you can't find anything... There be nothing anymore. A general recommendation in this case would be to replace the missing container with a new one, and give feedback to the original owner about the state of that particular location. After all, it's about fun and active participation in a world-wide community. Geocaches in Mauritius? Yes, there are currently about 45 geocaches spread all over the island, and even a single in Rodriguez - that's gonna be a tough one. Hopefully, we will get increasing numbers as Geocaching.com allows, no better, even encourages you to hide new containers at your locations of choice. I think this is going to be real fun for us during the upcoming weeks and months. Especially, when we are travelling to other countries and transfer so-called trackable items between geocaches. On my first impression, Geocaching.com seems to be very mature, open and community-oriented. There are literally hundreds of thousands geocache 'hunters' all over the world. And usually finding a container remote from your home is very rewarding. I'll keep you updated in these matters during the next months to come...

    Read the article

  • User Group Meeting Summary - April 2010

    - by Michael Stephenson
    Thanks to everyone who could make it to what turned out to be an excellent SBUG event.  First some thanks to:  Speakers: Anthony Ross and Elton Stoneman Host: The various people at Hitachi who helped to organise and arrange the venue.   Session 1 - Getting up and running with Windows Mobile and the Windows Azure Service Bus In this session Anthony discussed some considerations for using Windows Mobile and the Windows Azure Service Bus from a real-world project which Hitachi have been working on with EasyJet.  Anthony also walked through a simplified demo of the concepts which applied on the project.   In addition to the slides and demo it was also very interesting to discuss with the guys involved on this project to hear about their real experiences developing with the Azure Service Bus and some of the limitations they have had to work around in Windows Mobiles ability to interact with the service bus.   On the back of this session we will look to do some further activities around this topic and the guys offered to share their wish list of features for both Windows Mobile and Windows Azure which we will look to share for user group discussion.   Another interesting point was the cost aspects of using the ISB which were very low.   Session 2 - The Enterprise Cache In the second session Elton used a few slides which are based around one of his customer scenario's where they are looking into the concept of an Enterprise Cache within the organisation.  Elton discusses this concept and also a codeplex project he is putting together which allows you to take advantage of a cache with various providers such as Memcached, AppFabric Caching and Ncache.   Following the presentation it was interesting to hear peoples thoughts on various aspects such as the enterprise cache versus an out of process application cache.  Also there was interesting discussion around how people would like to search the cache in the future.   We will again look to put together some follow-up activity on this   Meeting Summary Following the meeting all slide decks are saved in the skydrive location where we keep content from all meetings: http://cid-40015ea59a1307c8.skydrive.live.com/browse.aspx/.Public/SBUG/SBUG%20Meetings/2010%20April   Remember that the details of all previous events are on the following page. http://uksoabpm.org/Events.aspx   Competition We had three copies of the Windows Identity Foundation Patterns and Practices book that were raffles on the night, it would be great to hear any feedback on the book from those who won it.   Recording The user group meeting was recorded and we will look to make this available online sometime soon.   UG Business The following things were discussed as general UG topics:   We will change the name of the user group to the UK Connected Systems User Group to we are more inline with other user groups who cover similar topics and we believe this will help us to attract more members.  The content or focus of the user group is not expected to change.   The next meeting is 26th May and can be registered at the following link: http://sbugmay2010.eventbrite.com/

    Read the article

  • DBCC MEMUSAGE in 2005/8 ?

    - by steveh99999
    I used to like using undocumented command DBCC MEMUSAGE in SQL 2000 to see which tables were using space in SQL data cache. In SQL 2005, this command is not longer present. Instead a DMV – sys.dm_os_buffer_descriptors – can be used to display data cache contents,  but this doesn’t quite give you the same output as DBCC MEMUSAGE. I’m also aware that you can use Quest’s spotlight tool to view a summary of data cache contents. Using  this post by Umachandar Jayachandran  of Microsoft, I was able to create the following equivalent for SQL 2005/8. I’ve wrapped Umachandar’s original query in a CTE to produce summary information :- ;WITH memusage_CTE AS (SELECT bd.database_id, bd.file_id, bd.page_id, bd.page_type , COALESCE(p1.object_id, p2.object_id) AS object_id , COALESCE(p1.index_id, p2.index_id) AS index_id , bd.row_count, bd.free_space_in_bytes, CONVERT(TINYINT,bd.is_modified) AS 'DirtyPage' FROM sys.dm_os_buffer_descriptors AS bd JOIN sys.allocation_units AS au ON au.allocation_unit_id = bd.allocation_unit_id OUTER APPLY ( SELECT TOP(1) p.object_id, p.index_id FROM sys.partitions AS p WHERE p.hobt_id = au.container_id AND au.type IN (1, 3) ) AS p1 OUTER APPLY ( SELECT TOP(1) p.object_id, p.index_id FROM sys.partitions AS p WHERE p.partition_id = au.container_id AND au.type = 2 ) AS p2 WHERE  bd.database_id = DB_ID() AND bd.page_type IN ('DATA_PAGE', 'INDEX_PAGE') ) SELECT TOP 20 DB_NAME(database_id) AS 'Database',OBJECT_NAME(object_id,database_id) AS 'Table Name', index_id,COUNT(*) AS 'Pages in Cache', SUM(dirtyPage) AS 'Dirty Pages' FROM memusage_CTE GROUP BY database_id, object_id, index_id ORDER BY COUNT(*) DESC I’m not 100% happy with the results of the above query however… I’ve noticed that on a busy BizTalk messageBox database  it will return information on pages that contain GHOST rows – . ie where data has already been deleted but has yet to be cleaned-up by a background process – I’m need to investigate further why cache on this server apparently contains so much GHOST data… For more information on the background ghost cleanup process, see this article by Paul Randall. However, I think the results of this query should still be of interest to a DBA. I have another post to come shortly regarding an example I encountered where this information proved useful to me… I notice in SQL 2008, sys.dm_os_buffer_descriptors gained an extra column – numa_mode – I’m interested to see how this is populated and how useful this column can be on a NUMA-enabled system. I’m assuming in theory you could use this column to help analyse how your tables are spread across Numa-enabled data-cache ?

    Read the article

  • SPARC M7 Chip - 32 cores - Mind Blowing performance

    - by Angelo-Oracle
    The M7 Chip Oracle just announced its Next Generation Processor at the HotChips HC26 conference. As the Tech Lead in our Systems Division's Partner group, I had a front row seat to the extraordinary price performance advantage of Oracle current T5 and M6 based systems. Partner after partner tested  these systems and were impressed with it performance. Just read some of the quotes to see what our partner has been saying about our hardware. We just announced our next generation processor, the M7. This has 32 cores (up from 16-cores in T5 and 12-cores in M6). With 20 nm technology  this is our most advanced processor. The processor has more cores than anything else in the industry today. After the Sun acquisition Oracle has released 5 processors in 4 years and this is the 6th.  The S4 core  The M7 is built using the foundation of the S4 core. This is the next generation core technology. Like its predecessor, the S4 has 8 dynamic threads. It increases the frequency while maintaining the Pipeline depth. Each core has its own fine grain power estimator that keeps the core within its power envelop in 250 nano-sec granularity. Each core also includes Software in Silicon features for Application Acceleration Support. Each core includes features to improve Application Data Integrity, with almost no performance loss. The core also allows using part of the Virtual Address to store meta-data.  User-Level Synchronization Instructions are also part of the S4 core. Each core has 16 KB Instruction and 16 KB Data L1 cache. The Core Clusters  The cores on the M7 chip are organized in sets of 4-core clusters. The core clusters share  L2 cache.  All four cores in the complex share 256 KB of 4 way set associative L2 Instruction Cache, with over 1/2 TB/s of throughput. Two cores share 256 KB of 8 way set associative L2 Data Cache, with over 1/2 TB/s of throughput. With this innovative Core Cluster architecture, the M7 doubles core execution bandwidth. to maximize per-thread performance.  The Chip  Each  M7 chip has 8 sets of these core-clusters. The chip has 64 MB on-chip L3 cache. This L3 caches is shared among all the cores and is partitioned into 8 x 8 MB chunks. Each chunk is  8-way set associative cache. The aggregate bandwidth for the L3 cache on the chip is over 1.6TB/s. Each chip has 4 DDR4 memory controllers and can support upto 16 DDR4 DIMMs, allowing for 2 TB of RAM/chip. The chip also includes 4 internal links of PCIe Gen3 I/O controllers.  Each chip has 7 coherence links, allowing for 8 of these chips to be connected together gluelessly. Also 32 of these chips can be connected in an SMP configuration. A potential system with 32 chips will have 1024 cores and 8192 threads and 64 TB of RAM.  Software in Silicon The M7 chip has many built in Application Accelerators in Silicon. These features will be exposed to our Software partners using the SPARC Accelerator Program.  The M7  has built-in logic to decompress data at the speed of memory access. This means that applications can directly work on compressed data in memory increasing the data access rates. The VA Masking feature allows the use of part of the virtual address to store meta-data.  Realtime Application Data Integrity The Realtime Application Data Integrity feature helps applications safeguard against invalid, stale memory reference and buffer overflows. The first 4-bits if the Pointer can be used to store a version number and this version number is also maintained in the memory & cache lines. When a pointer accesses memory the hardware checks to make sure the two versions match. A SEGV signal is raised when there is a mismatch. This feature can be used by the Database, applications and the OS.  M7 Database In-Memory Query Accelerator The M7 chip also includes a In-Silicon Query Engines.  These accelerate tasks that work on In-Memory Columnar Vectors. Oracle In-Memory options stores data in Column Format. The M7 Query Engine can speed up In-Memory Format Conversion, Value and Range Comparisons and Set Membership lookups. This engine can work on Compressed data - this means not only are we accelerating the query performance but also increasing the memory bandwidth for queries.  SPARC Accelerated Program  At the Hotchips conference we also introduced the SPARC Accelerated Program to provide our partners and third part developers access to all the goodness of the M7's SPARC Application Acceleration features. Please get in touch with us if you are interested in knowing more about this program. 

    Read the article

  • Windows Azure: Caching

    - by xamlnotes
    I was poking around today and found this great article on caching: http://www.cloudcomputingdevelopment.net/cache-management-with-windows-azure/ Caching is a great way to boost application performance and keep down overhead on a database or file system. Its also great when you have say 3 web roles as shown in this articles Figure 2 that can share the same cache. If one of the roles goes offline then the cache is still there and can be used. You can change out your asp.net caching to use this pretty easy. Its pretty cool. There’s a sample that’s mentioned in the article that shows how to use this. You can download the cache here.

    Read the article

  • A quick look at: sys.dm_os_buffer_descriptors

    - by Jonathan Allen
    SQL Server places data into cache as it reads it from disk so as to speed up future queries. This dmv lets you see how much data is cached at any given time and knowing how this changes over time can help you ensure your servers run smoothly and are adequately resourced to run your systems. This dmv gives the number of cached pages in the buffer pool along with the database id that they relate to: USE [tempdb] GO SELECT COUNT(*) AS cached_pages_count , CASE database_id WHEN 32767 THEN 'ResourceDb' ELSE DB_NAME(database_id) END AS Database_name FROM sys.dm_os_buffer_descriptors GROUP BY DB_NAME(database_id) , database_id ORDER BY cached_pages_count DESC; This gives you results which are quite useful, but if you add a new column with the code: …to convert the pages value to show a MB value then they become more relevant and meaningful. To see how your server reacts to queries, start up SSMS and connect to a test server and database – mine is called AdventureWorks2008. Make sure you start from a know position by running: -- Only run this on a test server otherwise your production server's-- performance may drop off a cliff and your phone will start ringing. DBCC DROPCLEANBUFFERS GO Now we can run a query that would normally turn a DBA’s hair white: USE [AdventureWorks2008] go SELECT * FROM [Sales].[SalesOrderDetail] AS sod INNER JOIN [Sales].[SalesOrderHeader] AS soh ON [sod].[SalesOrderID] = [soh].[SalesOrderID] …and then check our cache situation: A nice low figure – not! Almost 2000 pages of data in cache equating to approximately 15MB. Luckily these tables are quite narrow; if this had been on a table with more columns then this could be even more dramatic. So, let’s make our query more efficient. After resetting the cache with the DROPCLEANBUFFERS and FREEPROCCACHE code above, we’ll only select the columns we want and implement a WHERE predicate to limit the rows to a specific customer. SELECT [sod].[OrderQty] , [sod].[ProductID] , [soh].[OrderDate] , [soh].[CustomerID] FROM [Sales].[SalesOrderDetail] AS sod INNER JOIN [Sales].[SalesOrderHeader] AS soh ON [sod].[SalesOrderID] = [soh].[SalesOrderID] WHERE [soh].[CustomerID] = 29722 …and check our effect cache: Now that is more sympathetic to our server and the other systems sharing its resources. I can hear you asking: “What has this got to do with logging, Jonathan?” Well, a smart DBA will keep an eye on this metric on their servers so they know how their hardware is coping and be ready to investigate anomalies so that no ‘disruptive’ code starts to unsettle things. Capturing this information over a period of time can lead you to build a picture of how a database relies on the cache and how it interacts with other databases. This might allow you to decide on appropriate schedules for over night jobs or otherwise balance the work of your server. You could schedule this job to run with a SQL Agent job and store the data in your DBA’s database by creating a table with: IF OBJECT_ID('CachedPages') IS NOT NULL DROP TABLE CachedPages CREATE TABLE CachedPages ( cached_pages_count INT , MB INT , Database_Name VARCHAR(256) , CollectedOn DATETIME DEFAULT GETDATE() ) …and then filling it with: INSERT INTO [dbo].[CachedPages] ( [cached_pages_count] , [MB] , [Database_Name] ) SELECT COUNT(*) AS cached_pages_count , ( COUNT(*) * 8.0 ) / 1024 AS MB , CASE database_id WHEN 32767 THEN 'ResourceDb' ELSE DB_NAME(database_id) END AS Database_name FROM sys.dm_os_buffer_descriptors GROUP BY database_id After this has been left logging your system metrics for a while you can easily see how your databases use the cache over time and may see some spikes that warrant your attention. This sort of logging can be applied to all sorts of server statistics so that you can gather information that will give you baseline data on how your servers are performing. This means that when you get a problem you can see what statistics are out of their normal range and target you efforts to resolve the issue more rapidly.

    Read the article

  • Page output caching for dynamic web applications

    - by Mike Ellis
    I am currently working on a web application where the user steps (forward or back) through a series of pages with "Next" and "Previous" buttons, entering data until they reach a page with the "Finish" button. Until finished, all data is stored in Session state, then sent to the mainframe database via web services at the end of the process. Some of the pages display data from previous pages in order to collect additional information. These pages can never be cached because they are different for every user. For pages that don't display this dynamic data, they can be cached, but only the first time they load. After that, the data that was previously entered needs to be displayed. This requires Page_Load to fire, which means the page can't be cached at that point. A couple of weeks ago, I knew almost nothing about implementing page caching. Now I still don't know much, but I know a little bit, and here is the solution that I developed with the help of others on my team and a lot of reading and trial-and-error. We have a base page class defined from which all pages inherit. In this class I have defined a method that sets the caching settings programmatically. For pages that can be cached, they call this base page method in their Page_Load event within a if(!IsPostBack) block, which ensures that only the page itself gets cached, not the data on the page. if(!IsPostBack) {     ...     SetCacheSettings();     ... } protected void SetCacheSettings() {     Response.Cache.AddValidationCallback(new HttpCacheValidateHandler(Validate), null);     Response.Cache.SetExpires(DateTime.Now.AddHours(1));     Response.Cache.SetSlidingExpiration(true);     Response.Cache.SetValidUntilExpires(true);     Response.Cache.SetCacheability(HttpCacheability.ServerAndNoCache); } The AddValidationCallback sets up an HttpCacheValidateHandler method called Validate which runs logic when a cached page is requested. The Validate method signature is standard for this method type. public static void Validate(HttpContext context, Object data, ref HttpValidationStatus status) {     string visited = context.Request.QueryString["v"];     if (visited != null && "1".Equals(visited))     {         status = HttpValidationStatus.IgnoreThisRequest; //force a page load     }     else     {         status = HttpValidationStatus.Valid; //load from cache     } } I am using the HttpValidationStatus values IgnoreThisRequest or Valid which forces the Page_Load event method to run or allows the page to load from cache, respectively. Which one is set depends on the value in the querystring. The value in the querystring is set up on each page in the "Next" and "Previous" button click event methods based on whether the page that the button click is taking the user to has any data on it or not. bool hasData = HasPageBeenVisited(url); if (hasData) {     url += VISITED; } Response.Redirect(url); The HasPageBeenVisited method determines whether the destination page has any data on it by checking one of its required data fields. (I won't include it here because it is very system-dependent.) VISITED is a string constant containing "?v=1" and gets appended to the url if the destination page has been visited. The reason this logic is within the "Next" and "Previous" button click event methods is because 1) the Validate method is static which doesn't allow it to access non-static data such as the data fields for a particular page, and 2) at the time at which the Validate method runs, either the data has not yet been deserialized from Session state or is not available (different AppDomain?) because anytime I accessed the Session state information from the Validate method, it was always empty.

    Read the article

  • hosting environment for delivering FLVs

    - by Gotys
    What would be the ideal hardware setup for pushing lots of bandwith on a tube site? We have ever-expanding cloud storage where users upload the movies, then we have these web-delivery machines which cache the FLV files on its local harddrives and deliver them to users. Each cache machine can deliver 1200 mbits/s , if it has SAS 8 harddrives. Such a cache machine costs us $550/month for 8x160gb -- so each machine can cache only 160GB at any given time. If we want to cache more then 160gb , we need to add another machine..another $550/month..etc. This is very un-economical so I am wondering if we have any experts here who can figure out a better setup. I've been looking into "gluster FS", but I am not sure if this thing can push a lot of bandwith. Any ideas highly appreciated. Thank you!

    Read the article

  • Installing 12.04 within 11.04

    - by user288752
    I recently installed 11.04 from an installation disk (overwriting Windows in the process). I know 11.04 is no longer supported but I had no problems subsequently upgrading it to 12.04 (via 11.10) a couple of months ago on another device. This time though, things are different. I can't upgrade through update manager because Ubuntu then tells me I have no internet connection, which is (obviously incorrect). I have tried to circumvent the problem by downloading the 12:04 iso from ubuntu.com directly but now I'm troubled by something else. The download is succesfull but after mounting the iso I can't interact with it. When I try to access the Wubi it gives me the following message: Archive: /home/lars/.cache/.fr-7g75Fe/wubi.exe [/home/lars/.cache/.fr-7g75Fe/wubi.exe] End-of-central-directory signature not found. Either this file is not a zipfile, or it constitutes one disk of a multi-part archive. In the latter case the central directory and zipfile comment will be found on the last disk(s) of this archive. zipinfo: cannot find zipfile directory in one of /home/lars/.cache/.fr-7g75Fe/wubi.exe or /home/lars/.cache/.fr-7g75Fe/wubi.exe.zip, and cannot find /home/lars/.cache/.fr-7g75Fe/wubi.exe.ZIP, period. What am I doing wrong here?

    Read the article

  • Fixing Chrome&rsquo;s AJAX Request Caching Bug

    - by Steve Wilkes
    I recently had to make a set of web pages restore their state when the user arrived on them after clicking the browser’s back button. The pages in question had various content loaded in response to user actions, which meant I had to manually get them back into a valid state after the page loaded. I got hold of the page’s data in a JavaScript ViewModel using a JQuery ajax call, then iterated over the properties, filling in the fields as I went. I built in the ability to describe dependencies between inputs to make sure fields were filled in in the correct order and at the correct time, and that all worked nicely. To make sure the browser didn’t cache the AJAX call results I used the JQuery’s cache: false option, and ASP.NET MVC’s OutputCache attribute for good measure. That all worked perfectly… except in Chrome. Chrome insisted on retrieving the data from its cache. cache: false adds a random query string parameter to make the browser think it’s a unique request – it made no difference. I made the AJAX call a POST – it made no difference. Eventually what I had to do was add a random token to the URL (not the query string) and use MVC routing to deliver the request to the correct action. The project had a single Controller for all AJAX requests, so this route: routes.MapRoute( name: "NonCachedAjaxActions", url: "AjaxCalls/{cacheDisablingToken}/{action}", defaults: new { controller = "AjaxCalls" }, constraints: new { cacheDisablingToken = "[0-9]+" }); …and this amendment to the ajax call: function loadPageData(url) { // Insert a timestamp before the URL's action segment: var indexOfFinalUrlSeparator = url.lastIndexOf("/"); var uniqueUrl = url.substring(0, indexOfFinalUrlSeparator) + new Date().getTime() + "/" + url.substring(indexOfFinalUrlSeparator); // Call the now-unique action URL: $.ajax(uniqueUrl, { cache: false, success: completePageDataLoad }); } …did the trick.

    Read the article

  • Why did Ubuntu suddenly get so slow?

    - by user101383
    12.10 has been slowing down mysteriously. Normally, in past versions, I can log in, open Firefox, and it will pop up within seconds. 12.10 is like that upon install too, though once I install my old apps, it gets very slow by Ubuntu standards. After login the hard drive will just make noise for a while before the OS will do anything. Hardware: enter description: Desktop Computer product: XPS 8300 () vendor: Dell Inc. serial: B6G2WR1 width: 64 bits capabilities: smbios-2.6 dmi-2.6 vsyscall32 configuration: boot=normal chassis=desktop uuid=44454C4C-3600-1047-8032-C2C04F575231 core description: Motherboard product: 0Y2MRG vendor: Dell Inc. physical id: 0 version: A00 serial: ..CN7360419G04VQ. slot: To Be Filled By O.E.M. *cpu description: CPU product: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz vendor: Intel Corp. physical id: 4 bus info: cpu@0 version: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz serial: To Be Filled By O.E.M. slot: CPU 1 size: 1600MHz capacity: 1600MHz width: 64 bits clock: 100MHz capabilities: x86-64 fpu fpu_exception wp vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx rdtscp constant_tsc arch_perfmon pebs bts rep_good nopl xtopology nonstop_tsc aperfmperf pni pclmulqdq dtes64 monitor ds_cpl vmx smx est tm2 ssse3 cx16 xtpr pdcm pcid sse4_1 sse4_2 x2apic popcnt tsc_deadline_timer aes xsave avx lahf_lm ida arat epb xsaveopt pln pts dtherm tpr_shadow vnmi flexpriority ept vpid cpufreq configuration: cores=4 enabledcores=1 threads=2 *-cache:0 description: L1 cache physical id: 5 slot: L1-Cache size: 256KiB capacity: 256KiB capabilities: internal write-through unified *-cache:1 description: L2 cache physical id: 6 slot: L2-Cache size: 1MiB capacity: 1MiB capabilities: internal write-through unified *-cache:2 DISABLED description: L3 cache physical id: 7 slot: L3-Cache size: 8MiB capacity: 8MiB capabilities: internal write-back unified *-memory description: System Memory physical id: 20 slot: System board or motherboard size: 8GiB *-bank:0 description: SODIMM DDR3 Synchronous 1333 MHz (0.8 ns) product: NT2GC64B88B0NF-CG vendor: Nanya physical id: 0 serial: 7228183 slot: DIMM3 size: 2GiB width: 64 bits clock: 1333MHz (0.8ns) *-bank:1 description: SODIMM DDR3 Synchronous 1333 MHz (0.8 ns) product: NT2GC64B88B0NF-CG vendor: Nanya physical id: 1 serial: 1E28183 slot: DIMM1 size: 2GiB width: 64 bits clock: 1333MHz (0.8ns) *-bank:2 description: SODIMM DDR3 Synchronous 1333 MHz (0.8 ns) product: NT2GC64B88B0NF-CG vendor: Nanya physical id: 2 serial: 9E28183 slot: DIMM4 size: 2GiB width: 64 bits clock: 1333MHz (0.8ns) *-bank:3 description: SODIMM DDR3 Synchronous 1333 MHz (0.8 ns) product: NT2GC64B88B0NF-CG vendor: Nanya physical id: 3 serial: 5527183 slot: DIMM2 size: 2GiB width: 64 bits clock: 1333MHz (0.8ns) *-firmware description: BIOS vendor: Dell Inc. physical id: 0 version: A05 date: 09/21/2011 size: 64KiB capacity: 4032KiB capabilities: mca pci upgrade shadowing escd cdboot bootselect socketedrom edd int13floppy1200 int13floppy720 int13floppy2880 int5printscreen int9keyboard int14serial int17printer int10video acpi usb zipboot biosbootspecification *-pci description: Host bridge product: 2nd Generation Core Processor Family DRAM Controller vendor: Intel Corporation physical id: 100 bus info: pci@0000:00:00.0 version: 09 width: 32 bits clock: 33MHz *-pci:0 description: PCI bridge product: Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port vendor: Intel Corporation physical id: 1 bus info: pci@0000:00:01.0 version: 09 width: 32 bits clock: 33MHz capabilities: pci pm msi pciexpress normal_decode bus_master cap_list configuration: driver=pcieport resources: irq:40 ioport:e000(size=4096) memory:fe600000-fe6fffff ioport:d0000000(size=268435456) *-display description: VGA compatible controller product: Juniper [Radeon HD 5700 Series] vendor: Advanced Micro Devices [AMD] nee ATI physical id: 0 bus info: pci@0000:01:00.0 version: 00 width: 64 bits clock: 33MHz capabilities: pm pciexpress msi vga_controller bus_master cap_list rom configuration: driver=radeon latency=0 resources: irq:44 memory:d0000000-dfffffff memory:fe620000-fe63ffff ioport:e000(size=256) memory:fe600000-fe61ffff *-multimedia description: Audio device product: Juniper HDMI Audio [Radeon HD 5700 Series] vendor: Advanced Micro Devices [AMD] nee ATI physical id: 0.1 bus info: pci@0000:01:00.1 version: 00 width: 64 bits clock: 33MHz capabilities: pm pciexpress msi bus_master cap_list configuration: driver=snd_hda_intel latency=0 resources: irq:48 memory:fe640000-fe643fff *-communication description: Communication controller product: 6 Series/C200 Series Chipset Family MEI Controller #1 vendor: Intel Corporation physical id: 16 bus info: pci@0000:00:16.0 version: 04 width: 64 bits clock: 33MHz capabilities: pm msi bus_master cap_list configuration: driver=mei latency=0 resources: irq:45 memory:fe708000-fe70800f *-usb:0 description: USB controller product: 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 vendor: Intel Corporation physical id: 1a bus info: pci@0000:00:1a.0 version: 05 width: 32 bits clock: 33MHz capabilities: pm debug ehci bus_master cap_list configuration: driver=ehci_hcd latency=0 resources: irq:16 memory:fe707000-fe7073ff *-multimedia description: Audio device product: 6 Series/C200 Series Chipset Family High Definition Audio Controller vendor: Intel Corporation physical id: 1b bus info: pci@0000:00:1b.0 version: 05 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: driver=snd_hda_intel latency=0 resources: irq:46 memory:fe700000-fe703fff *-pci:1 description: PCI bridge product: 6 Series/C200 Series Chipset Family PCI Express Root Port 1 vendor: Intel Corporation physical id: 1c bus info: pci@0000:00:1c.0 version: b5 width: 32 bits clock: 33MHz capabilities: pci pciexpress msi pm normal_decode bus_master cap_list configuration: driver=pcieport resources: irq:41 memory:fe500000-fe5fffff *-network description: Network controller product: BCM4313 802.11b/g/n Wireless LAN Controller vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:02:00.0 version: 01 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: driver=bcma-pci-bridge latency=0 resources: irq:16 memory:fe500000-fe503fff *-pci:2 description: PCI bridge product: 6 Series/C200 Series Chipset Family PCI Express Root Port 4 vendor: Intel Corporation physical id: 1c.3 bus info: pci@0000:00:1c.3 version: b5 width: 32 bits clock: 33MHz capabilities: pci pciexpress msi pm normal_decode bus_master cap_list configuration: driver=pcieport resources: irq:42 memory:fe400000-fe4fffff *-network description: Ethernet interface product: NetLink BCM57788 Gigabit Ethernet PCIe vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 01 serial: 18:03:73:e1:a7:71 size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.123 duplex=full firmware=sb ip=192.168.1.3 latency=0 link=yes multicast=yes port=MII speed=100Mbit/s resources: irq:47 memory:fe400000-fe40ffff *-usb:1 description: USB controller product: 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 vendor: Intel Corporation physical id: 1d bus info: pci@0000:00:1d.0 version: 05 width: 32 bits clock: 33MHz capabilities: pm debug ehci bus_master cap_list configuration: driver=ehci_hcd latency=0 resources: irq:23 memory:fe706000-fe7063ff *-isa description: ISA bridge product: H67 Express Chipset Family LPC Controller vendor: Intel Corporation physical id: 1f bus info: pci@0000:00:1f.0 version: 05 width: 32 bits clock: 33MHz capabilities: isa bus_master cap_list configuration: latency=0 *-storage description: SATA controller product: 6 Series/C200 Series Chipset Family SATA AHCI Controller vendor: Intel Corporation physical id: 1f.2 bus info: pci@0000:00:1f.2 version: 05 width: 32 bits clock: 66MHz capabilities: storage msi pm ahci_1.0 bus_master cap_list configuration: driver=ahci latency=0 resources: irq:43 ioport:f070(size=8) ioport:f060(size=4) ioport:f050(size=8) ioport:f040(size=4) ioport:f020(size=32) memory:fe705000-fe7057ff *-serial UNCLAIMED description: SMBus product: 6 Series/C200 Series Chipset Family SMBus Controller vendor: Intel Corporation physical id: 1f.3 bus info: pci@0000:00:1f.3 version: 05 width: 64 bits clock: 33MHz configuration: latency=0 resources: memory:fe704000-fe7040ff ioport:f000(size=32) *-scsi:0 physical id: 1 logical name: scsi0 capabilities: emulated *-disk description: ATA Disk product: Hitachi HUA72201 vendor: Hitachi physical id: 0.0.0 bus info: scsi@0:0.0.0 logical name: /dev/sda version: JP4O serial: JPW9J0HD21BTZC size: 931GiB (1TB) capabilities: partitioned partitioned:dos configuration: ansiversion=5 sectorsize=512 signature=000641dc *-volume:0 description: EXT4 volume vendor: Linux physical id: 1 bus info: scsi@0:0.0.0,1 logical name: /dev/sda1 logical name: / version: 1.0 serial: 4e3d91b7-fd38-4f44-a9e9-ba3c39b926ec size: 585GiB capacity: 585GiB capabilities: primary journaled extended_attributes large_files huge_files dir_nlink recover extents ext4 ext2 initialized configuration: created=2012-10-21 16:26:50 filesystem=ext4 lastmountpoint=/ modified=2012-10-29 18:12:08 mount.fstype=ext4 mount.options=rw,relatime,errors=remount-ro,data=ordered mounted=2012-10-29 18:12:08 state=mounted *-volume:1 description: Extended partition physical id: 2 bus info: scsi@0:0.0.0,2 logical name: /dev/sda2 size: 7823MiB capacity: 7823MiB capabilities: primary extended partitioned partitioned:extended *-logicalvolume description: Linux swap / Solaris partition physical id: 5 logical name: /dev/sda5 capacity: 7823MiB capabilities: nofs *-volume:2 description: Windows NTFS volume physical id: 3 bus info: scsi@0:0.0.0,3 logical name: /dev/sda3 version: 3.1 serial: 84a92aae-347b-7940-a2d1-f4745b885ef2 size: 337GiB capacity: 337GiB capabilities: primary bootable ntfs initialized configuration: clustersize=4096 created=2012-10-21 18:43:39 filesystem=ntfs modified_by_chkdsk=true mounted_on_nt4=true resize_log_file=true state=dirty upgrade_on_mount=true *-scsi:1 physical id: 2 logical name: scsi1 capabilities: emulated *-cdrom description: DVD-RAM writer product: DVDRWBD DH-12E3S vendor: PLDS physical id: 0.0.0 bus info: scsi@1:0.0.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/sr0 version: MD11 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=nodisc *-scsi:2 physical id: 3 bus info: usb@2:1.8 logical name: scsi6 capabilities: emulated scsi-host configuration: driver=usb-storage *-disk:0 description: SCSI Disk physical id: 0.0.0 bus info: scsi@6:0.0.0 logical name: /dev/sdb configuration: sectorsize=512 *-disk:1 description: SCSI Disk physical id: 0.0.1 bus info: scsi@6:0.0.1 logical name: /dev/sdc configuration: sectorsize=512 *-disk:2 description: SCSI Disk physical id: 0.0.2 bus info: scsi@6:0.0.2 logical name: /dev/sdd configuration: sectorsize=512 *-disk:3 description: SCSI Disk product: MS/MS-Pro vendor: Generic- physical id: 0.0.3 bus info: scsi@6:0.0.3 logical name: /dev/sde version: 1.03 serial: 3 capabilities: removable configuration: sectorsize=512 *-medium physical id: 0 logical name: /dev/sde

    Read the article

  • Trying to install Team viewer on Ubuntu 12.04

    - by Teknikk
    I recently got Ubuntu installed on my server, I wanted to install TeamViewer so i could easy manage the virtual machines, However, I get errors when installing it from App store?, And I also get errors, but more detailed on the terminal. Error output: tek@tek-G53SW:~/Download$ sudo dpkg -i ipts teamviewer_linux_x64.deb dpkg: error processing ipts (--install): cannot access archive: No such file or directory (Reading database ... 142115 files and directories currently installed.) Preparing to replace teamviewer7 7.0.9360 (using teamviewer_linux_x64.deb) ... Unpacking replacement teamviewer7 ... dpkg: dependency problems prevent configuration of teamviewer7: teamviewer7 depends on libc6-i386 (>= 2.7); however: Package libc6-i386 is not installed. teamviewer7 depends on lib32asound2; however: Package lib32asound2 is not installed. teamviewer7 depends on lib32z1; however: Package lib32z1 is not installed. teamviewer7 depends on ia32-libs; however: Package ia32-libs is not installed. dpkg: error processing teamviewer7 (--install): dependency problems - leaving unconfigured Errors were encountered while processing: ipts teamviewer7 I tried to install it manually, but with no luck, I heard some others has this problems. I am running Ubuntu 12.04 x64. Error @ sudo apt-get install libc6-i386 lib32asound2 lib32z1 ia32-libs : tek@tek-G53SW:~/Download$ sudo apt-get install libc6-i386 lib32asound2 lib32z1 ia32-libs Reading package lists... Done Building dependency tree Reading state information... Done You might want to run 'apt-get -f install' to correct these: The following packages have unmet dependencies: ia32-libs : Depends: ia32-libs-multiarch E: Unmet dependencies. Try 'apt-get -f install' with no packages (or specify a solution). tek@tek-G53SW:~/Download$ More errors tek@tek-G53SW:~/Download$ sudo apt-get -f install [sudo] password for tek: Reading package lists... Done Building dependency tree Reading state information... Done Correcting dependencies... Done The following packages will be REMOVED: teamviewer7 0 upgraded, 0 newly installed, 1 to remove and 0 not upgraded. 1 not fully installed or removed. After this operation, 81.9 MB disk space will be freed. Do you want to continue [Y/n]? y (Reading database ... 142441 files and directories currently installed.) Removing teamviewer7 ... tek@tek-G53SW:~/Download$ sudo apt-get install libc6-i386 lib32asound2 lib32z1 ia32-libs Reading package lists... Done Building dependency tree Reading state information... Done lib32z1 is already the newest version. libc6-i386 is already the newest version. lib32asound2 is already the newest version. Some packages could not be installed. This may mean that you have requested an impossible situation or if you are using the unstable distribution that some required packages have not yet been created or been moved out of Incoming. The following information may help to resolve the situation: The following packages have unmet dependencies: ia32-libs : Depends: ia32-libs-multiarch E: Unable to correct problems, you have held broken packages. tek@tek-G53SW:~/Download$ sudo apt-get install ia32-libs-multiarch Reading package lists... Done Building dependency tree Reading state information... Done Some packages could not be installed. This may mean that you have requested an impossible situation or if you are using the unstable distribution that some required packages have not yet been created or been moved out of Incoming. The following information may help to resolve the situation: The following packages have unmet dependencies: ia32-libs-multiarch:i386 : Depends: gstreamer0.10-plugins-good:i386 but it is not going to be installed Depends: gtk2-engines:i386 but it is not going to be installed Depends: gtk2-engines-murrine:i386 but it is not going to be installed Depends: gtk2-engines-pixbuf:i386 but it is not going to be installed Depends: gtk2-engines-oxygen:i386 but it is not going to be installed Depends: ibus-gtk:i386 but it is not going to be installed Depends: libcanberra-gtk-module:i386 but it is not going to be installed Depends: libcups2:i386 but it is not going to be installed Depends: libcupsimage2:i386 but it is not going to be installed Depends: libfontconfig1:i386 but it is not going to be installed Depends: libgail-common:i386 but it is not going to be installed Depends: libgphoto2-2:i386 but it is not going to be installed Depends: libgtk2.0-0:i386 but it is not going to be installed Depends: libnss3:i386 but it is not going to be installed Depends: libqt4-opengl:i386 but it is not going to be installed Depends: libqt4-qt3support:i386 but it is not going to be installed Depends: libqt4-scripttools:i386 but it is not going to be installed Depends: libqt4-svg:i386 but it is not going to be installed Depends: libqtgui4:i386 but it is not going to be installed Depends: libqtwebkit4:i386 but it is not going to be installed Depends: librsvg2-common:i386 but it is not going to be installed Depends: libsane:i386 but it is not going to be installed E: Unable to correct problems, you have held broken packages. tek@tek-G53SW:~/Download$

    Read the article

  • Best practices for caching search queries

    - by David Esteves
    I am trying to improve performance of my ASP.net Web Api by adding a data cache but I am not sure how exactly to go about it as it seems to be more complex than most caching scenarios. An example is I have a table of Locations and an api to retrieve locations via search, for an autocomplete. /api/location/Londo and the query would be something like SELECT * FROM Locations WHERE Name like 'Londo%' These locations change very infrequently so I would like to cache them to prevent trips to the database for no real reason and improve the response time. Looking at caching options I am using the Windows Azure Appfabric system, the problem is it's just a key/value cache. Since I can only retrieve items based on keys I couldn't actually use it for this scenario as far as Im aware. Is what I am trying to do bad use of a caching system? Should I try looking into NoSql DB which could possibly run as a cache for something like this to improve performance? Should I just cache the entire table/collection in a single key with a specific data structure which could assist with the searching and then do the search upon retrieval of the data?

    Read the article

  • Unmet Dependencies with kdelibs5-data

    - by Jitesh
    I was trying to install Amarok 1.4 on Ubuntu 12.04 (Gnome-classic), by following this instructions. Problem started after giving these two commands dpkg -i kdelibs5-data_4.6.2-0ubuntu4_all.deb dpkg -i kdelibs-data_3.5.10.dfsg.1-5ubuntu2_all.deb Now, immediately after these commands, Ubuntu Updater popped up and gave me an error that the package catalog is broken and needs to be repaired. Nothing can be installed or removed till then. It also offered a suggestion to run apt-get install -f. I tried that, but again got the same error.Also tried apt-get clean followed by apt-get install -f. Again got the following output: jitesh@jitesh-desktop:~$ sudo apt-get clean jitesh@jitesh-desktop:~$ sudo apt-get install -f Reading package lists... Done Building dependency tree Reading state information... Done Correcting dependencies... Done The following extra packages will be installed: kdelibs5-data The following packages will be upgraded: kdelibs5-data 1 upgraded, 0 newly installed, 0 to remove and 18 not upgraded. 2 not fully installed or removed. Need to get 2,832 kB of archives. After this operation, 2,998 kB disk space will be freed. Do you want to continue [Y/n]? y Get:1 http: //in.archive.ubuntu.com/ubuntu/precise-updates/main kdelibs5-data all 4:4.8.4a-0ubuntu0.2 [2,832 kB] Fetched 2,832 kB in 32s (86.6 kB/s) dpkg: dependency problems prevent configuration of kdelibs5-data: libplasma3 (4:4.8.4a-0ubuntu0.2) breaks kdelibs5-data (<< 4:4.6.80~) and is installed. Version of kdelibs5-data to be configured is 4:4.6.2-0ubuntu4. kate-data (4:4.8.4-0ubuntu0.1) breaks kdelibs5-data (<< 4:4.6.90) and is installed. Version of kdelibs5-data to be configured is 4:4.6.2-0ubuntu4. katepart (4:4.8.4-0ubuntu0.1) breaks kdelibs5-data (<< 4:4.6.90) and is installed. Version of kdelibs5-data to be configured is 4:4.6.2-0ubuntu4. dpkg: error processing kdelibs5-data (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of kdelibs-data: kdelibs-data depends on kdelibs5-data; however: Package kdelibs5-data is not configured yet. No apport report written because MaxReports is reached already dpkg: error processing kdelibs-data (--configure): dependency problems - leaving unconfigured No apport report written because MaxReports is reached already Errors were encountered while processing: kdelibs5-data kdelibs-data W: Duplicate sources.list entry http://archive.canonical.com/ubuntu/ precise/partner i386 Packages (/var/lib/apt/lists/archive.canonical.com_ubuntu_dists_precise_partner_binary-i386_Packages) W: You may want to run apt-get update to correct these problems E: Sub-process /usr/bin/dpkg returned an error code (1) As I thought the error was related to configuring kdelibs, I tried to configure using dpkg. But got the following errors: jitesh@jitesh-desktop:~$ sudo dpkg --configure -a dpkg: dependency problems prevent configuration of kdelibs5-data: libplasma3 (4:4.8.4a-0ubuntu0.2) breaks kdelibs5-data (<< 4:4.6.80~) and is installed. Version of kdelibs5-data to be configured is 4:4.6.2-0ubuntu4. kate-data (4:4.8.4-0ubuntu0.1) breaks kdelibs5-data (<< 4:4.6.90) and is installed. Version of kdelibs5-data to be configured is 4:4.6.2-0ubuntu4. katepart (4:4.8.4-0ubuntu0.1) breaks kdelibs5-data (<< 4:4.6.90) and is installed. Version of kdelibs5-data to be configured is 4:4.6.2-0ubuntu4. dpkg: error processing kdelibs5-data (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of kdelibs-data: kdelibs-data depends on kdelibs5-data; however: Package kdelibs5-data is not configured yet. dpkg: error processing kdelibs-data (--configure): dependency problems - leaving unconfigured Errors were encountered while processing: kdelibs5-data kdelibs-data jitesh@jitesh-desktop:~$ Now I dont have any idea how to proceed. I am unable to install anything from Software Centre or using Terminal now. Some basic info: Core2Duo, dual booting Ubuntu 12.04 with Win7. Fresh install of Ubuntu 12.04 (not upgrade). Incidentally, I had first upgraded from 10.04 and had succesfully installed Amarok 1.4 following this same method. But due to other issues, i had to format and do a clean install of 12.04. Now when I tried to install Amarok 1.4, I'm getting these errors. I also have digiKam and k3b installed, if that can be of any help. I use digiKam a lot, so removing KDE is not feasible for me. Any help on this issue will be highly appreciated. Thanks in advance.

    Read the article

  • AWR Performance Report and Read by Other Session Waits

    - by user702295
    For the questions regarding "read by other session" and its relation to "db file sequential/scattered read", the logic is like this: When a "db file sequential/scattered read" is done, the blocks are either already in the cache or on the disk.  Since any operation on blocks is done in the cache and since and the issue is "read by other session" I will relate to the case the blocks are on the disk. Process A is reading the needed block from the disk to the cache.  During that time, if process B (and C and others) need the same block, it will wait on "read by other session".  A and B can be threads of the same process running in parallel or unrelated processes.  For example two processes doing full table scan on mdp_matrix etc. Solutions for that can be lowering the number of processes competing on the same blocks, increasing PCTFREE.  If it is a full table scan, maybe an index is missing that can result in less blocks being read from the cache and so on.

    Read the article

  • Too much I/O in the morning ?

    - by steveh99999
    Interesting little improvement on a SQL 2005 system I encountered recently….. Some background - this system had a fairly ‘traditional OLTP’ workload ie  heavily used during day – till around 9pm, then had a batch window for several hours, then not much activity in the early hours of the day, until normal workload resumed the following morning. Using perfmon, I noticed that every morning, we would see a big spike in SQL Server I/O when the application started to be used... As it was 2005 I decided to look at what tables were in cache before and after the overnight batch processing ran… ( using DMV equivalent of dbcc memusage that I posted earlier). Here’s what I saw :-     So, contents of data cache split fairly evenly between my 'important/heavily used' tables.   After this:- some application batch processing,backups, DBCC checks and reindexes were run.  A fairly standard batch I'd suggest. Cache contents then looked like this :- Hmmmm – most of cache is now being used by a table I’ve described as ‘unimportant’. Why ? Well, that table was the last to be reindexed…. purely due to luck, as  the reindexing stored procedure performing a loop in alphabetical order through all application tables...  When the application starts to be used again – all this ‘unimportant’ data has to be replaced in cache by data that is heavily used… So, we changed the overnight reindex scripts –  the most heavily accessed tables are now the last to be reindexed. Obvious really, but we did see a significant reduction in early-morning I/O after changing the order of our reindexing.  

    Read the article

  • Where is a good place to start to learn about custom caching in .Net

    - by John
    I'm looking to make some performance enhancements to our site, but I'm not sure exactly where to begin. We have some custom object caching, but I think that we can do better. Our Business We aggregate news stories on a news type of web site. We get approximately 500-1000 new stories per week. We have index pages that show various lists of the items and details pages that show the individual stories. Our Current Use case: Getting an Individual Story User makes a request The Data Access Layer(DAL) checks to see if the item is in cache and if item is fresh (15 minutes). If the item is not in cache or is not fresh, retrieve the item from SQL Server, save to cache and return to user. Problems with this approach The pull nature of caching means that users have to pay the waiting cost every time that the cache is refreshed. Once a story is published, it changes infrequently and I think that we should replace the pull model with something better. My initial thoughts My initial thought is that stories should ALL be stored locally in some type of dictionary. (Cache or is there another, better way?). If the story is not found, then make a trip to the database, update the local dictionary and send the item back. Since there may be occasional updates to stories, this should be an entirely process from the user. I watched a video by Brent Ozar, How StackOverflow Scales SQL Server, in which Brent states "the fastest database query is the one that you don't make". Where do I start? At this point, I don't know exactly what the solution is. Is it caching? Is there a better way of using local storage? Do I use a Dictionary, OrderedDictionary, List ? It seems daunting and I'm just looking for some good starting points to learn more about how to do this type of optimization.

    Read the article

  • Graphite Running using daemon tools getting defunct

    - by pradeepchhetri
    I am running carbon-cache.py and carbon-aggregator.py using daemon tools. When I made some changes in the storage-schema.conf and tried to restart the carbon-cache.py, I found that it is becoming zombie very frequently. root 3367 3366 0 03:23 pts/1 00:00:00 supervise carbon-aggregator root 3371 3366 0 03:23 pts/1 00:00:00 supervise carbon-cache root 3373 3367 3 03:23 pts/1 00:00:02 /usr/bin/python /usr/bin/carbon-aggregator.py --debug start root 3379 3372 0 03:23 pts/1 00:00:00 multilog t /var/log/multilog/carbon-cache root 3382 3368 0 03:23 pts/1 00:00:00 multilog t /var/log/multilog/carbon-aggregator root 3638 3371 21 03:24 pts/1 00:00:00 [carbon-cache.py] <defunct> Can someone tell me what may be the reason ?

    Read the article

< Previous Page | 94 95 96 97 98 99 100 101 102 103 104 105  | Next Page >