Search Results

Search found 68398 results on 2736 pages for 'file encodings'.

Page 98/2736 | < Previous Page | 94 95 96 97 98 99 100 101 102 103 104 105  | Next Page >

  • Using modified date of file for comparison. Is it safe?

    - by papadi
    I want to make a procedure that does one way syncrhonization of a folder between a server and a client. I was thinking to use ModifiedDate as a criterio, provided that only the date of the server files will be used. Procedure will not use Modified dates of files on the client at all. It will read dates from the server and compare them with dates read from the server last time the procedure run. Do you think this is safe? Is there any possibility that Modified Date will not be changed when a file is edited or it will be changed without touching the contents of the file (eg. from some strange antivirus programs)?

    Read the article

  • How can you check if a file exists before including/importing it in JSP?

    - by codeninja
    Assuming that requestScope.importMe is expecting a path to a jsp file <c:choose> <c:when test="${!empty requestScope.importMe && fileExists(requestScope.importMe) }"> <c:import url="${requestScope.importMe}" /> ... How can I check if the file exists before trying to include it so that an error is not thrown? I'd like to avoid using inline Java. Something using one of the JSTL tags is the preferred approach.

    Read the article

  • Reading bmp file for steganography

    - by Shantanu Gupta
    I am trying to read a bmp file in C++(Turbo). But i m not able to print binary stream. I want to encode txt file into it and decrypt it. How can i do this. I read that bmp file header is of 54 byte. But how and where should i append txt file in bmp file. ? I know only Turbo C++, so it would be helpfull for me if u provide solution or suggestion related to topic for the same. int main() { ifstream fr; //reads ofstream fw; // wrrites to file char c; int random; clrscr(); char file[2][100]={"s.bmp","s.txt"}; fr.open(file[0],ios::binary);//file name, mode of open, here input mode i.e. read only if(!fr) cout<<"File can not be opened."; fw.open(file[1],ios::app);//file will be appended if(!fw) cout<<"File can not be opened"; while(!fr) cout<<fr.get(); // error should be here. but not able to find out what error is it fr.close(); fw.close(); getch(); } This code is running fine when i pass txt file in binary mode

    Read the article

  • An easy way to create Side by Side registrationless COM Manifests with Visual Studio

    - by Rick Strahl
    Here's something I didn't find out until today: You can use Visual Studio to easily create registrationless COM manifest files for you with just a couple of small steps. Registrationless COM lets you use COM component without them being registered in the registry. This means it's possible to deploy COM components along with another application using plain xcopy semantics. To be sure it's rarely quite that easy - you need to watch out for dependencies - but if you know you have COM components that are light weight and have no or known dependencies it's easy to get everything into a single folder and off you go. Registrationless COM works via manifest files which carry the same name as the executable plus a .manifest extension (ie. yourapp.exe.manifest) I'm going to use a Visual FoxPro COM object as an example and create a simple Windows Forms app that calls the component - without that component being registered. Let's take a walk down memory lane… Create a COM Component I start by creating a FoxPro COM component because that's what I know and am working with here in my legacy environment. You can use VB classic or C++ ATL object if that's more to your liking. Here's a real simple Fox one: DEFINE CLASS SimpleServer as Session OLEPUBLIC FUNCTION HelloWorld(lcName) RETURN "Hello " + lcName ENDDEFINE Compile it into a DLL COM component with: BUILD MTDLL simpleserver FROM simpleserver RECOMPILE And to make sure it works test it quickly from Visual FoxPro: server = CREATEOBJECT("simpleServer.simpleserver") MESSAGEBOX( server.HelloWorld("Rick") ) Using Visual Studio to create a Manifest File for a COM Component Next open Visual Studio and create a new executable project - a Console App or WinForms or WPF application will all do. Go to the References Node Select Add Reference Use the Browse tab and find your compiled DLL to import  Next you'll see your assembly in the project. Right click on the reference and select Properties Click on the Isolated DropDown and select True Compile and that's all there's to it. Visual Studio will create a App.exe.manifest file right alongside your application's EXE. The manifest file created looks like this: xml version="1.0" encoding="utf-8"? assembly xsi:schemaLocation="urn:schemas-microsoft-com:asm.v1 assembly.adaptive.xsd" manifestVersion="1.0" xmlns:asmv1="urn:schemas-microsoft-com:asm.v1" xmlns:asmv2="urn:schemas-microsoft-com:asm.v2" xmlns:asmv3="urn:schemas-microsoft-com:asm.v3" xmlns:dsig="http://www.w3.org/2000/09/xmldsig#" xmlns:co.v1="urn:schemas-microsoft-com:clickonce.v1" xmlns:co.v2="urn:schemas-microsoft-com:clickonce.v2" xmlns="urn:schemas-microsoft-com:asm.v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" asmv2:size="27293" hash xmlns="urn:schemas-microsoft-com:asm.v2" dsig:Transforms dsig:Transform Algorithm="urn:schemas-microsoft-com:HashTransforms.Identity" / dsig:Transforms dsig:DigestMethod Algorithm="http://www.w3.org/2000/09/xmldsig#sha1" / dsig:DigestValuepuq+ua20bbidGOWhPOxfquztBCU=dsig:DigestValue hash typelib tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" version="1.0" helpdir="" resourceid="0" flags="HASDISKIMAGE" / comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file assembly Now let's finish our super complex console app to test with: using System; using System.Collections.Generic; using System.Text; namespace ConsoleApplication1 {     class Program     {         static voidMain(string[] args)         { Type type = Type.GetTypeFromProgID("simpleserver.simpleserver",true); dynamic server = Activator.CreateInstance(type); Console.WriteLine(server.HelloWorld("rick")); Console.ReadLine(); } } } Now run the Console Application… As expected that should work. And why not? The COM component is still registered, right? :-) Nothing tricky about that. Let's unregister the COM component and then re-run and see what happens. Go to the Command Prompt Change to the folder where the DLL is installed Unregister with: RegSvr32 -u simpleserver.dll      To be sure that the COM component no longer works, check it out with the same test you used earlier (ie. o = CREATEOBJECT("SimpleServer.SimpleServer") in your development environment or VBScript etc.). Make sure you run the EXE and you don't re-compile the application or else Visual Studio will complain that it can't find the COM component in the registry while compiling. In fact now that we have our .manifest file you can remove the COM object from the project. When you run run the EXE from Windows Explorer or a command prompt to avoid the recompile. Watch out for embedded Manifest Files Now recompile your .NET project and run it… and it will most likely fail! The problem is that .NET applications by default embeds a manifest file into the compiled EXE application which results in the externally created manifest file being completely ignored. Only one manifest can be applied at a time and the compiled manifest takes precedency. Uh, thanks Visual Studio - not very helpful… Note that if you use another development tool like Visual FoxPro to create your EXE this won't be an issue as long as the tool doesn't automatically add a manifest file. Creating a Visual FoxPro EXE for example will work immediately with the generated manifest file as is. If you are using .NET and Visual Studio you have a couple of options of getting around this: Remove the embedded manifest file Copy the contents of the generated manifest file into a project manifest file and compile that in To remove an embedded manifest in a Visual Studio project: Open the Project Properties (Alt-Enter on project node) Go down to Resources | Manifest and select | Create Application without a Manifest   You can now add use the external manifest file and it will actually be respected when the app runs. The other option is to let Visual Studio create the manifest file on disk and then explicitly add the manifest file into the project. Notice on the dialog above I did this for app.exe.manifest and the manifest actually shows up in the list. If I select this file it will be compiled into the EXE and be used in lieu of any external files and that works as well. Remove the simpleserver.dll reference so you can compile your code and run the application. Now it should work without COM registration of the component. Personally I prefer external manifests because they can be modified after the fact - compiled manifests are evil in my mind because they are immutable - once they are there they can't be overriden or changed. So I prefer an external manifest. However, if you are absolutely sure nothing needs to change and you don't want anybody messing with your manifest, you can also embed it. The option to either is there. Watch for Manifest Caching While working trying to get this to work I ran into some problems at first. Specifically when it wasn't working at first (due to the embedded schema) I played with various different manifest layouts in different files etc.. There are a number of different ways to actually represent manifest files including offloading to separate folder (more on that later). A few times I made deliberate errors in the schema file and I found that regardless of what I did once the app failed or worked no amount of changing of the manifest file would make it behave differently. It appears that Windows is caching the manifest data for a given EXE or DLL. It takes a restart or a recompile of either the EXE or the DLL to clear the caching. Recompile your servers in order to see manifest changes unless there's an outright failure of an invalid manifest file. If the app starts the manifest is being read and caches immediately. This can be very confusing especially if you don't know that it's happening. I found myself always recompiling the exe after each run and before making any changes to the manifest file. Don't forget about Runtimes of COM Objects In the example I used above I used a Visual FoxPro COM component. Visual FoxPro is a runtime based environment so if I'm going to distribute an application that uses a FoxPro COM object the runtimes need to be distributed as well. The same is true of classic Visual Basic applications. Assuming that you don't know whether the runtimes are installed on the target machines make sure to install all the additional files in the EXE's directory alongside the COM DLL. In the case of Visual FoxPro the target folder should contain: The EXE  App.exe The Manifest file (unless it's compiled in) App.exe.manifest The COM object DLL (simpleserver.dll) Visual FoxPro Runtimes: VFP9t.dll (or VFP9r.dll for non-multithreaded dlls), vfp9rENU.dll, msvcr71.dll All these files should be in the same folder. Debugging Manifest load Errors If you for some reason get your manifest loading wrong there are a couple of useful tools available - SxSTrace and SxSParse. These two tools can be a huge help in debugging manifest loading errors. Put the following into a batch file (SxS_Trace.bat for example): sxstrace Trace -logfile:sxs.bin sxstrace Parse -logfile:sxs.bin -outfile:sxs.txt Then start the batch file before running your EXE. Make sure there's no caching happening as described in the previous section. For example, if I go into the manifest file and explicitly break the CLSID and/or ProgID I get a detailed report on where the EXE is looking for the manifest and what it's reading. Eventually the trace gives me an error like this: INFO: Parsing Manifest File C:\wwapps\Conf\SideBySide\Code\app.EXE.     INFO: Manifest Definition Identity is App.exe,processorArchitecture="x86",type="win32",version="1.0.0.0".     ERROR: Line 13: The value {AAaf2c2811-0657-4264-a1f5-06d033a969ff} of attribute clsid in element comClass is invalid. ERROR: Activation Context generation failed. End Activation Context Generation. pinpointing nicely where the error lies. Pay special attention to the various attributes - they have to match exactly in the different sections of the manifest file(s). Multiple COM Objects The manifest file that Visual Studio creates is actually quite more complex than is required for basic registrationless COM object invokation. The manifest file can be simplified a lot actually by stripping off various namespaces and removing the type library references altogether. Here's an example of a simplified manifest file that actually includes references to 2 COM servers: xml version="1.0" encoding="utf-8"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name = "sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" threadingModel="apartment" / file assembly Simple enough right? Routing to separate Manifest Files and Folders In the examples above all files ended up in the application's root folder - all the DLLs, support files and runtimes. Sometimes that's not so desirable and you can actually create separate manifest files. The easiest way to do this is to create a manifest file that 'routes' to another manifest file in a separate folder. Basically you create a new 'assembly identity' via a named id. You can then create a folder and another manifest with the id plus .manifest that points at the actual file. In this example I create: App.exe.manifest A folder called App.deploy A manifest file in App.deploy All DLLs and runtimes in App.deploy Let's start with that master manifest file. This file only holds a reference to another manifest file: App.exe.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / dependency dependentAssembly assemblyIdentity name="App.deploy" version="1.0.0.0" type="win32" / dependentAssembly dependency assembly   Note this file only contains a dependency to App.deploy which is another manifest id. I can then create App.deploy.manifest in the current folder or in an App.deploy folder. In this case I'll create App.deploy and in it copy the DLLs and support runtimes. I then create App.deploy.manifest. App.deploy.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.deploy" type="win32" version="1.0.0.0" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name="sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" threadingModel="Apartment" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" / file assembly   In this manifest file I then host my COM DLLs and any support runtimes. This is quite useful if you have lots of DLLs you are referencing or if you need to have separate configuration and application files that are associated with the COM object. This way the operation of your main application and the COM objects it interacts with is somewhat separated. You can see the two folders here:   Routing Manifests to different Folders In theory registrationless COM should be pretty easy in painless - you've seen the configuration manifest files and it certainly doesn't look very complicated, right? But the devil's in the details. The ActivationContext API (SxS - side by side activation) is very intolerant of small errors in the XML or formatting of the keys, so be really careful when setting up components, especially if you are manually editing these files. If you do run into trouble SxsTrace/SxsParse are a huge help to track down the problems. And remember that if you do have problems that you'll need to recompile your EXEs or DLLs for the SxS APIs to refresh themselves properly. All of this gets even more fun if you want to do registrationless COM inside of IIS :-) But I'll leave that for another blog post…© Rick Strahl, West Wind Technologies, 2005-2011Posted in COM  .NET  FoxPro   Tweet (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article

  • Perforce: File tampered with after resolve - edit or revert

    - by fbrereto
    I'm doing an integration in Perforce and am being met with the following: p4 integrate -1 -d -i -t -r -b my_branchspec //Foo/file.txt#6 - integrate from //Bar/file.txt#6 p4 resolve -am /Foo/file.txt - merging //Bar/file.txt#6 /Foo/file.txt tampered with before resolve - edit or revert. It seems no matter what I do, I am unable to make this issue go away: the next forward integration will show a similar message. The file is a text file. I can confirm that the MD5 hash for both files before the integration takes place is the same. What other issues might be going on with this file that I can resolve to fix this nagging message?

    Read the article

  • Problem with XLSX file on Office 2003 with Compatibility Pack

    - by MadBoy
    I've this machine which has Office 2003 installed with Compatibility Pack. User received one file which she has to work with in XLSX format (file has to stay in that format so options to save it as XLS can be skipped). When she opens the file from Desktop or any other location it gives an error like "Cannot find the file in following location" and in the background it starts Converting XLSX file to XLS. In the end Excel is opened up with some random file name X000008.xls (Read Only) which is just 1 to 1 conversion of the XLSX document. However if I go directly to Excel and use File / Open and try to open the XLSX file no error or conversion is done. The file is writable and can be saved in XLSX format. The file name is simple like This_file something.XLSX, I've even tried to remove all spaces but it gave no better results. Anyone has any recommendations? So far I have done: 1. Uninstalled Compatibility Pack and installed it again. Tried opening it without any other updates and the error still pops out. In progress: I am now running all possible updates of office (like 5 of them) which i suppos won't fix anything (as they were applied when I've uninstalled compatibility pack). Next in run will be (not yet done) installing Windows XP SP3. What other things I can do?

    Read the article

  • unzip file on small drive

    - by David Oneill
    I have a zip file that contains many files. Each file in the zip file is about 100MB, and is compressed about 10% (IE it is about 90MB in the zip file). The whole zip file is 20GB, and I'm trying to unzip it onto a drive that has only 30GB free. On Windows 7, how can I unzip a zip file on my laptop's harddrive that doesn't have enough space for both the zipped and unzipped copies of the file? IE can I tell windows to remove stuff from the zip file as it is uncompressed?

    Read the article

  • Cannot open Pivot Table source file

    - by Ken
    Excel Pivot table error is: Cannot open Pivot Table source file C:\Users\UserName\AppData\Roaming\Microsoft\Excel\DatabaseName (version1).TableName I’ve seen other questions and answers with the same topic, but I think this is different. I believe I know why the error is occurring: Excel closed unexpectantly and did autosave with (version1) attached to the original file name and saved it in the C:\User etc. above , which is the default recovery location. I opened the recovered file in Excel, saved it as version1 on the server where the original file was located, deleted the original file, and renamed the version1 to the original name. When I go to PivotTable Tools? Options? Change Data Source, it shows only the Table and Range, which are correct, but it does not show the file name or path. The version1 and the renamed file both had the same structure, so the same source table was in both, by they were different files. How do I change the source file from what it is looking for to my renamed file? PS- The (version1) file that it says it is looking for is not in the autosave location, i.e. it is not at the path where it says it is looking in. Thank you for any help Ken

    Read the article

  • HOSTS ignored when disconnected [closed]

    - by Synetech
    Problem I’m seeing a strange and extremely frustrating problem. Any system that is not connect to the Internet (Windows 7 shows the no Internet access icon because it cannot constantly ping Microsoft’s servers) cannot even access locally hosted servers. Hypothesis The problem appears to be that the HOSTS file is not being used to resolve DNS entries when there are no active NICs. Tests / Reproduction You can reproduce it as so: Disconnect a system from the Internet (make sure all wired and wireless connections are disconnected). If necessary, add an entry to the HOSTS file (e.g., 127.0.0.1 foobar or 127.0.0.1 foobar.com) Open a command-prompt Type ping foobar or ping foobar.com Observations The screenshots below show a clear and demonstrative example. In the first snap, a laptop is connected to a router wirelessly. The HOSTS file has only three entries and they resolve just fine. In the second snap, the wireless radio is turned off, so the entries in the HOSTS file are ignored. Moreover, notice that pinging localhost still works even without any active NICs (as does 127.0.0.1), but it is using the IPv6 address (must be hard-coded). You can see the same results in Windows XP with no IPv6 installed, so it has nothing to do with IPv6. I tried pining what should have resolved to 127.0.0.1 while the desktop system (with no wireless NICs) was connected via its Ethernet adapter, then again after pulling the cable from the router and waiting a couple of seconds, then again after plugging the cable back in. The same thing happens if instead of pulling out the cable, the NIC is disabled through software (the [Disable] button in the NIC’s Status dialog or via Device Manager). Conclusions It looks as though the HOSTS file is only being read and used if there is an active NIC, otherwise it is being ignored. This makes some sense in that if there are no active network adapters, then presumably there will not be any network activity, and thus no need to resolve host names via the HOSTS file. This assumption is specious however because it precludes locally hosted virtual servers. The HOSTS file should be used regardless of external DNS server connectivity, otherwise you cannot use simple/consistent/testing-production names for locally hosted servers when not connected to the Internet (for example web servers; help servers for Visual Studio, 3dsmax, etc.; and so on). Question Does anyone know how to force Windows to use the HOSTS file even if there are no active NICs? Appendix Figure 1: While the wireless NIC is connected to the router (the cable-modem is in standby, so no external Internet connectivity). Figure 2: With the wireless radio turned off (the Ethernet port is not unconnected in both cases). Figure 3: Same results in XP with no IPv6

    Read the article

  • Looping through a batch file only if the response is "everything is okay"

    - by PeanutsMonkey
    I have a batch file that loops through the contents of a directory and compresses the files in the directory as follows; for %%a in (c:\data\*.*) do if "%%~xa" == "" "C:\Program Files\7-Zip\7za.exe" a -tzip -mx9 "%%a.zip" "%%a" Seeing that I am using 7zip to compress the file, it returns the message "everything is okay" if it has successfully compressed the file and it then moves onto the next file in any. What I would like to do is the following; Only move to the next file if the response is "everything is okay" If the response is anything but "everything is okay", the error is logged Since an error has occurred, it attempts to compress the file again Once when it has succeeded i.e. "everything is okay" it goes to the next file Steps 3 & 4 only occur a maximum of 3 times before it gives up and moves onto the next file. How can I achieve this?

    Read the article

  • Config file (App.config) does not update on new installation

    - by Muhammad Kashif Nadeem
    I am creating setup of my project using Visula Studio 2008. I am facing problem in setup installation. If I uninstall old setup (application) and install the new one then config file (App.config) updates the attributes (surely it is new file) of config file but if I install new setup without uninstalling the old one then config file does not update. from config file I mean MyProject.exe.config Why is this behavior of config file. Should it not be updated on installation of the new setup Is this possible to delete and copy the config file of new setup? Is there a way to update only config file forcefully during installation. Thanks for your help!

    Read the article

  • What could cause the file command in Linux to report a text file as data?

    - by Jonah Bishop
    I have a couple of C++ source files (one .cpp and one .h) that are being reported as type data by the file command in Linux. When I run the file -bi command against these files, I'm given this output (same output for each file): application/octet-stream; charset=binary Each file is clearly plain-text (I can view them in vi). What's causing file to misreport the type of these files? Could it be some sort of Unicode thing? Both of these files were created in Windows-land (using Visual Studio 2005), but they're being compiled in Linux (it's a cross-platform application). Any ideas would be appreciated. Update: I don't see any null characters in either file. I found some extended characters in the .cpp file (in a comment block), removed them, but file still reports the same encoding. I've tried forcing the encoding in SlickEdit, but that didn't seem to have an effect. When I open the file in vim, I see a [converted] line as soon as I open the file. Perhaps I can get vim to force the encoding?

    Read the article

  • rename/delete a folder from multipart rar file

    - by kikio
    Hello. I've a question: (I sent it in past) I have multipart rar file. Their contents are: file.part01.rar: myfolder (is a folder) data.cab -- file.part02.rar: myfolder (is a folder) data.cab <- file.part03.rar: myfolder (is a folder) data.cab <- file.part04.rar: difffolder (is a folder) anfolder (is a folder) data.cab <- file.part05.rar: myfolder (is a folder) data.cab <-- I want to extract it, so I right-click on "file.part01.rar" and select "Extract to ...". It extract 3 files, but in part 4, WinRAR said: "CRC. This file is currput." I think it problem is in the folders name in part04.rar. Is there anyway to rename folders in part04.rar? and cut "data.cab" from "afolder" to "difffolder". I really need it!! it is very emergency!!!!!!!! Thank you .....

    Read the article

  • How to restore from file using Symantec NetBackup 7.5

    - by Tony
    I have an install of Symantec NetBackup 7.5 and I want to restore the server from a NetBackup image file. The file was created using NetBackup before I arrived. We had a hardware failure that corrupted this server and it needed to be rebuilt, now we want to restore from this image file. I can't for the life of me figure out how to restore from that file. I've installed the NetBackup application but it can't find the file when using the restore command within the application. If I double-click the file it opens the application then gives me the same "can't find any NetBackup files" error. I also can't simply drag the file into the NetBackup window. Any advice on how I restore from this file would be appreciated, thank you.

    Read the article

  • What is the difference between the BIN file generated by ImgBurn and UltraISO

    - by user275517
    I have a CD that I would like to generate a BIN file from (with a CUE file to accompany it). I used ImgBurn and UltraISO to to generate two BIN files. However, I have found out that BIN files generated by these programs are not identical (different file size). So, what is the difference between the BIN file formats and which one should I use to backup CD? The same applies to ISO file generation by these two programs - file size does not match.

    Read the article

  • SQL Error (1064) when importing data from SQL file

    - by mejpark
    I have a MySQL database, which was originally set up with the default latin1 character set and latin1_swedish_ci collation. I was using the database like this for sometime, until I noticed strange characters on my production web site, which is powered by a database exported from my development machine. At this point, I changed the default character set of the database and tables to utf8 and the collation to utf8_unicode_ci, converted the latin1 data inside each table to utf8 (using the 'convert data' option) and exported the database as a single SQL file using HeidiSQL. When the resulting SQL file is opened in Notepad++, several characters are rendered incorrectly. For example, en dashes (-) are displayed as – and e with accent (é) are displayed as é. I changed the encoding of the file from ANSI to UTF-8 (using the encoding menu option in Notepad++) and the offending characters are rendered correctly. I saved the new utf8-encoded SQL file and attempted to import the contents into the MySQL database on my production server. The import process fails with following error: /* SQL Error (1064): You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near '?# -------------------------------------------------------- # Host: ' at line 1 */ /* Error with snippets directory: The specified path was not found */ The head of the SQL file: # -------------------------------------------------------- # Host: 127.0.0.1 # Server version: 5.1.33-community # Server OS: Win32 # HeidiSQL version: 6.0.0.3773 # Date/time: 2011-04-20 09:48:36 # -------------------------------------------------------- It chokes on the first line of the file, which is commented out. Why is this happening? I didn't have a problem loading data from SQL files until I changed the character set and collation of the database. I came up with an ugly workaround to this problem by performing following steps: Export database as single SQL file using HeidiSQL Open resulting file in Notepad++ and convert from ANSI to UTF-8 encoding Create new empty file in Notepad++, paste in UTF-8 and save file normally What am I missing here?

    Read the article

  • rkhunter warns of inode change by no file modification date changes

    - by Nicholas Tolley Cottrell
    I have several systems running Centos 6 with rkhunter installed. I have a daily cron running rkhunter and reporting back via email. I very often get reports like: ---------------------- Start Rootkit Hunter Scan ---------------------- Warning: The file properties have changed: File: /sbin/fsck Current inode: 6029384 Stored inode: 6029326 Warning: The file properties have changed: File: /sbin/ip Current inode: 6029506 Stored inode: 6029343 Warning: The file properties have changed: File: /sbin/nologin Current inode: 6029443 Stored inode: 6029531 Warning: The file properties have changed: File: /bin/dmesg Current inode: 13369362 Stored inode: 13369366 From what I understand, rkhunter will usually report a changed hash and/or modification date on the scanned files to, so this leads me to think that there is no real change. My question: is there some other activity on the machine that could make the inode change (running ext4) or is this really yum making regular (~ once a week) changes to these files as part of normal security updates?

    Read the article

  • Gifsicle: How to set it to not overwrite the original GIF file if the resulting modified GIF file is larger than the original?

    - by galacticninja
    About Gifsicle: Gifsicle is a command-line tool for creating, editing, and getting information about GIF images and animations. One of its features is (from its website): Optimize your animations! This stores only the changed portion of each frame, and can radically shrink your GIFs. You can also use transparency to make them even smaller. Gifsicle’s optimizer is pretty powerful, and usually reduces animations to within a couple bytes of the best commercial optimizers. I call Gifsicle through this .BAT file in the Right Click - 'Send to' Menu: @echo off :compressFile "C:\Programs\Compression Scripts\gifsicle\bin\gifsicle.exe" --batch -V -O3 %1% echo. echo. SHIFT if exist %1% goto compressFile PAUSE This animated GIF file, however: http://i.minus.com/i7WdodY5Zwot3.gif, when its compression is optimized with Gifsicle with the above commands, results in a larger-filesized GIF file. Gifsicle overwrites the original GIF file with the resulting larger-filesized GIF file. Initial filesize: 7.57 MiB (7,942,886 bytes). After running through the above commands with Gifsicle: 7.64 MiB (8,017,622 bytes). Is there a way to prevent Gifsicle from overwriting the original file if its output file is larger than the original file, while still overwriting the original file if the output file is smaller? Details: OS: Windows 7 Gifsicle version: 1.63, from the binary provided here: http://www.lcdf.org/gifsicle/ Gifsicle manual

    Read the article

  • Alternative Windows Offline Files + Windows Backup + Previous Version Setup

    - by Herson
    Currently our documents are all hosted in a Windows 7 box. Users can access the files using Windows share and the documents are available offline (windows 7 feature). The documents are being backed up daily by Windows 7 backup and restore utility. Users can access previous versions of the file (from the backups) using Windows Explorer "previous versions" feature. This setup is currently working well, except for the following: We would prefer to have access to hourly versions of the file, not daily. The previous version mechanism is tied up to the backup mechanism. Windows 7 performs a full backup every week and incremental backup everyday. The previous versions of a file is actually what are the available in the backups. If you 20GB documents and want to maintain at least three(3) year history, you will use at minimum 3 years * 52 weeks * 20GB or about 3TB even if there are few changes in the documents. Its pretty inefficient use of space. Looking up previous versions of a file is very slow (tens of minutes). This is probably related to the previous issue - Windows has to traverse its all of its backups. I am considering using SVN + autocommit/autoupdate tortoisesvn. It will have the following advantages: Backups are easy and will also backup the whole history of each documents. (Just backup the repository). Creating previous versions can be frequent. I think svn commit / update can be done every two minutes or so. Users can sync over the net. However, I can see the following issues: More conflicts than the original setup because both multiple users can now edit the same file even both are online, i.e. can connect to the SVN repo. The users can off course lock the file first before editing, but that would mean they have to adjust. Delay on propagation of file changes. On windows 7 file sharing, changes made by one online user will be instantaneously available to other online users. With the SVN setup, changes will only be propagated when the users execute the svn add/commit/update sequence. Delay will be probably a few minutes. This workflow will no longer work: "Hi, I just edited document X, can you have a quick look?" I would like to ask the opinion of the community for alternative setups, or improvements on the above setups to work out the kinks.

    Read the article

  • Sync Local ICS File with Android via Exchange/Outlook

    - by sinDizzy
    At my company we have a 3rd party app which tracks off-hours duty for all of our engineers. The app is not web-enabled and we cannot make any changes to it. It does write a simple text file and I have created an app that translates that to an ICS file. My goal is to have that appear on my calendar on my Android phone. Here is the path I am working on: DutyApp -- TextFile -- ICSFile -- Outlook(exchange) -- Android (via exchange sync) My problems: If I place the ICS file on our FILE server and then in Outlook if I go to the option CalendarOpen CalendarFrom Internet it shows up in Outlook and looks pretty good. After a couple minutes it shows up on my Android phone as well. If I change the original ICS file those changes never display in Outlook and never sync to my Android phone. This seems to be a one shot deal almost like an import. Now if I place the ICS file on our WEB server and then in Outlook if I go to the option CalendarOpen CalendarFrom Internet and use webcal:\ as the address, it shows up in Outlook and also looks pretty good. Any changes I make to the original ICS file display in Outlook. However the entire calendar never shows up in Android. This calendar is a subscription and it seems, although am not sure, that Android doesn't display Exchange subscription calendars. Yes I know it works with Gmail subscription calendars but this is Exchange. So my question is what other options are there? We are behind a firewall so cant link the ICS file to a Gmail account. I can't put the ICS file anywhere else other than our file or web server.

    Read the article

  • Over writing output to a text file

    - by Naveen Gamage
    I'm trying to write wget command's output to a text file, but it always appends to the text file. #!/bin/sh download() { local url=$1 echo -n " " wget --progress=dot $url 2>&1 | grep --line-buffered "%" | \ sed -u -e "s,\.,,g" | awk '{printf("\b\b\b\b%4s", $2)}' echo " DONE" } file="$1" echo -n "Downloading $file:" download "$file" > file.log I tried using using > won't work, where am I doing wrong?

    Read the article

  • Full File Path in Reference to Another Workbook in Excel

    - by SHARIQ MUSANI
    I have two Excel files, one on D:\ and the other one on E:\. I reference one from the other, for example, using vlookup in the E: file to search from the D: file, like that: VLOOKUP(A1,'D:\SHARIQ\[FILE NAME.XLS]SHEETNAME'!A1:10,3,FALSE) As long as D:\SHARIQ\FILE NAME.XLS is open, I get the formula in the E: file displayed like this: VLOOKUP(A1,'[FILE NAME.XLS]SHEETNAME'!A1:10,3,FALSE) Why does it remove the whole path?

    Read the article

  • "pdf_open: Not a PDF 1.[1-5] file." when typesetting TeX file in TextMate

    - by Manti
    I have a TeX file, which is typeset by XeLaTeX. The file has \includegraphics{coverimage.eps} on the first page, and coverimage.eps is located in the same directory as the TeX file. OS: MacOS 10.6.5, TextMate 1.5.10, xelatex 3.1415926-2.2-0.9997.4 (TeX Live 2010) If I run xelatex doc.tex in console, file compiles without errors, and eps file is included. If I typeset it in TextMate (xelatex engine is selected in preferences), I get the following error: ** WARNING ** pdf_open: Not a PDF 1.[1-5] file. ** WARNING ** Failed to include image file "./coverimage.eps" ** WARNING ** >> Please check if ** WARNING ** >> rungs -q -dNOPAUSE -dBATCH -sPAPERSIZE=a0 -sDEVICE=pdfwrite -dCompatibilityLevel=%v -dAutoFilterGrayImages=false -dGrayImageFilter=/FlateEncode -dAutoFilterColorImages=false -dColorImageFilter=/FlateEncode -sOutputFile=%o %i -c quit ** WARNING ** >> %o = output filename, %i = input filename, %b = input filename without suffix ** WARNING ** >> can really convert "./coverimage.eps" to PDF format image. ** WARNING ** pdf: image inclusion failed for "coverimage.eps". ** WARNING ** Failed to read image file: coverimage.eps ** WARNING ** Interpreting special command PSfile (ps:) failed. ** WARNING ** >> at page="1" position="(107.149, 124.566)" (in PDF) ** WARNING ** >> xxx "PSfile="coverimage.eps" llx=0 lly=0 urx=408 ury=526 rwi=3809 and there is no image included in the resulting file (but text looks ok). I am not sure whether it is the error of xelatex or TextMate LaTeX bundle. What I tried to do: As I said, xelatex doc.tex from console works. The exact command line that TextMate uses is: xelatex -interaction=nonstopmode -file-line-error-style -synctex=1 But it works from console too. If I convert the image to pdf (and fix the .tex file accordingly), typesetting from TextMate works too. I tried running rungs with parameters specified in the error message, and got valid .pdf file with image as a result. I compared .log files from typesetting in TextMate and in console, they are absolutely identical except for this error message (in particular, version of xelatex is the same). Does anyone know what can cause this? Please tell me if you need any additional information. Thank you in advance.

    Read the article

< Previous Page | 94 95 96 97 98 99 100 101 102 103 104 105  | Next Page >