Search Results

Search found 10 results on 1 pages for 'perc6'.

Page 1/1 | 1 

  • Is There Anyway to Undo a Quick Initialize from a Perc6/i VD?

    - by Carlo71
    I stupidly fast initialized an existing Raid 5 Array Virtual disk with 10 Virtual Machines after creating a new Raid 5 Array. The VDs switched order on the list of the Perc Controller. My server is a PowerEdge R710 with a Perc 6/i Raid controller running ESXi 5.1. The Bios of the R710 and the Perc 6/i controller are both running the latest firmware. I tried the steps on this article: http://www.caseyfulton.com/dell-perc-6i-fast-initialize-how-to-restore/. However the BartPE just freezes on the Windows XP slapsh page. Does anybody know a full proof method? I have backups of the VMs, however I would like to avoid restoring all of them due to time constraint.

    Read the article

  • Is mismatched firmware on drives in a raid-6 a bad thing?

    - by bwerks
    Hi all, I recently expanded a raid-1 to a raid-6 with six drives. I ordered all four of the new drives from the same place, and all of them were advertised to be the same drives as the original two--Seagate 15krpm 146gb. However, when I was looking at the drives in the perc6/i utility, one of them appeared to be an earlier firmware version; it had S515, compared to the other five drives with S527. Sure enough, after inspecting the drive itself, the label advertised the earlier firmware version. Running Dell's SAS firmware upgrade utility should have in theory moved them all up to S52A, but when I ran it it moved the S527 drives up to S52A, and left the S515 drive untouched. Is this something to be worried about? If it's something that should be corrected, is there a way to target a particular drive for upgrade since the firmware utility didn't seem to do it by itself?

    Read the article

  • Dell 2950 Perc 6/i "physical disk" and "Enclosure(Backplane)" under Connector 1 in OMSA tree- Troubleshoot help

    - by user66357
    Just looking for someone who might know why this could occur... In OMSA, on my Dell 2950, there usually is only one "Physical Disks" child under "Enclosure (Backplane)" in the tree view. Currently, the tree looks like this: Dell PERC 6/i Integrated Connector 1 (RAID) Enclosure (Backplane) Physical Disks (1:04 good, 1:05 removed) Physical Disks (1:33 Ready but unused) Normally it's like this: Connector 1 (RAID) Enclosure (Backplane) Physical Disks (1:04 good, 1:05 good) From the front, 6 of 6 3.5" SAS drives are connected. The server is showing Slot 5 as bad and the disk as removed. It seems that the drive in Slot 5 is being sensed as external to the Enclosure. Any ideas why this would happen? Think I can get away with rebuilding the virtual disk by replacing 1:05 with 1:33? Thanks. UPDATE: The only options on the Physical Disk 1:33 were Assign as Global Hot Spare and Clear... After clearing, I assigned it as the Global Hot Spare. This allowed the rebuilding of the virtual disk. Hopefully it won't fail. I'm still unsure of the reason for this odd behavior. I'm checking the firmware next.

    Read the article

  • Dell Poweredge R410 replace PERC S100 with PERC 6i

    - by Robe Eleckers
    I want to replace the PERC S100 RAID Controller with a PERC6i to be able to use 4 SAS harddrives instead of only SATA drives. What exactly do I need for this, what I've got so far: PERC6i PCIe x8 card. 4 x SAS 300GB 15000rpm drives Some questions I have Do I need a different backplane to accomodate the SAS disks? If so, what kind of backplane? Do I need a special cable to hookup the PERC6i with the backplane? If so, what kind of cable? Thanks.

    Read the article

  • Dell Perc 6i with FreeBSD 8.1 errors with mfi0: COMMAND xxxxxxxx TIMEOUT AFTER xxx SECONDS

    - by jDempster
    We've recently bought two Dell PowerEdge R710 servers with Perc 6i controllers and 6x 135GB SAS Drives. We'd done some pretty extensive testing on a Dell PowerEdge R510 server with a Perc 6i and 4x 135GB SAS Drives running FreeBSD 8.1 for it's wonderful ZFS support and mfiutil. We hadn't had any problems with the R510 and had got to a point where we where happy with the performance of ZFS. Since running FreeBSD 8.1 on the R710 we've been getting errors from the RAID controller. mfi0: COMMAND 0xffffff80005d1770 TIMEOUT AFTER 6178 SECONDS This usually brings the system to a stand still. But it doesn't always happen, and performs very well up until it does happen. We've been running the disk as 3 mirrored drives striped in ZFS. So far we've noticed that running the drives with RAID10 on the RAID seems to work without errors (still testing). At first I thought hardware error as we'd been running FreeBSD on the R510 with the same controller without any issues. But both R710 have the same issue. All controllers are running the same firmware.

    Read the article

  • Can I move a one drive RAID 0 array on a PERC 6 to another server?

    - by zippy
    We have a Dell Poweredge 2970 with a PERC 6/i RAID controller. We have a one drive RAID 0 array (we wanted to add the drive as a JBOD but the PERC forces you to create an array to access it from the PERC). Can we take the one drive RAID 0 and move it to a new server (one that doesn't have a PERC)? Since there's only one drive in the "array" there's no striping going on...the only issue would seem to be if the PERC has some metadata on the drive that would prevent Windows from reading it. Does anyone have any experience with this scenario?

    Read the article

  • What is this Cable for? 4 Pin to 2 Pin from Riser to Perc in Dell R410

    - by Kyle Brandt
    I got a new raid card for a R410 server since the S300 that came with it doesn't support raid with Linux (No work around for this if SAS from what I could find). Anyways, the RAID card has 2 pins on it and there is a cable that that connects to a 4 pin connection on the riser. The cable only has two wires, one black and one red. What is this cable for? My guess would be maybe LED status for the front panel or something like that, but I am just guessing....

    Read the article

  • Dell 2950 Perc 6/i "physical disk" and "Enclosure(Backplane)" under Connector 1 in OMSA tree- Troubleshoot help

    - by user66357
    Just looking for someone who might know why this could occur... In OMSA, on my Dell 2950, there usually is only one "Physical Disks" child under "Enclosure (Backplane)" in the tree view. Currently, the tree looks like this: Dell PERC 6/i Integrated Connector 1 (RAID) Enclosure (Backplane) Physical Disks (1:04 good, 1:05 removed) Physical Disks (1:33 Ready but unused) Normally it's like this: Connector 1 (RAID) Enclosure (Backplane) Physical Disks (1:04 good, 1:05 good) From the front, 6 of 6 3.5" SAS drives are connected. The server is showing Slot 5 as bad and the disk as removed. It seems that the drive in Slot 5 is being sensed as external to the Enclosure. Any ideas why this would happen? Think I can get away with rebuilding the virtual disk by replacing 1:05 with 1:33? Thanks.

    Read the article

  • Getting access to physical drives in ESXi v5.5 installation on Dell PowerEdge R710 with PERC 6/i

    - by Big-Blue
    I've acquired a Dell PowerEdge R710 server a few days ago, which includes a PERC 6/i RAID controller. The server is now fitted with a SATA SSD, one SAS drive and four SATA HDD's, all of which I would like to be passed through to ESXi in an "as-is" state, without creating any logical drives in the RAID controller. Now, the ESXi v5.5 installation image I grabbed from the Dell homepage starts just fine but only lists the logical drives and connected flash drives as possible installation targets, not any of the physical drives. If I create a small logical drive on my SSD (which the PERC 6/i detects as SATA-SSD type), the ESXi install wizard lists the SSD value on that drive as false; which is far from optimal. I have also tried disabling the RAID controller entirely in the setup, but that also did not help. Everything that should enable passthrough is enabled in BIOS, but that shouldn't be a concern at this early stage of the ESXi installation. How would I be able to install ESXi v5.5 to a part of my SSD that is connected to the storage controller, while giving it entire physical access to the disk (to allow for SMART values to be read etc.)?

    Read the article