Search Results

Search found 42 results on 2 pages for 'rescan'.

Page 1/2 | 1 2  | Next Page >

  • How to rescan and remount drives on Ubuntu Hardy or Jaunty?

    - by pts
    When I connect an USB drive to an Ununtu Hardy and Jaunty system, the system mounts the partitions found on the drive, and opens a Nautilus window for each mounted partitions. Within Nautilus, I am able to unmount partitions. What I need is a command or action which forces the system to rescan the available drives and partitions, and automount each not mounted partition, including those which I've manually unmounted from Nautilus. sudo /etc/init.d/udev restart or ... reload doesn't do this. As of now, I just unplug the USB drive, and commect it again, which will force a scan and a mount on that drive. But I want to do force the rescan and remount without unplugging anything, preferably without the user having the know device or drive names.

    Read the article

  • iSCSI targets don't appear after rescan

    - by asmr
    Hi everybody, I have an Equallogic 4000PS SAN box to which I have connected 2 x ESX 4.0.0 hosts sharing the LUNs. I have an older ESX 3.5 host which I want to setup to share the same LUNs. I have setup a vmkernel port with 2 NICs attached to 2 the iSCSI switch. When I perform an iSCSI software adapter rescan, it takes a long time and it doesn't find the targets. In the ESX-3.5 host's log file I find these messages: Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.394 cpu5:1039)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.394 cpu5:1039)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.394 cpu5:1039)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.397 cpu0:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.397 cpu0:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.397 cpu0:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.442 cpu1:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.442 cpu1:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:52:48 sc59 vmkernel: 368:19:23:11.442 cpu1:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.874 cpu3:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.874 cpu3:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.874 cpu3:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.884 cpu4:1041)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.884 cpu4:1041)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.884 cpu4:1041)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.888 cpu3:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.888 cpu3:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:32.888 cpu3:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.042 cpu7:1039)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.042 cpu7:1039)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.042 cpu7:1039)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.044 cpu3:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.044 cpu3:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.044 cpu3:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.045 cpu4:1041)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.045 cpu4:1041)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:09 sc59 vmkernel: 368:19:27:33.045 cpu4:1041)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.308 cpu3:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.309 cpu3:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.309 cpu3:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.598 cpu2:1040)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.598 cpu2:1040)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.598 cpu2:1040)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.600 cpu7:1039)WARNING: SCSI: 279: SCSI device type 0xd is not supported. Cannot create target vmhba1:288:0 Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.600 cpu7:1039)WARNING: SCSI: 1293: LegacyMP Plugin could not claim path: vmhba1:288:0. Not supported Mar 30 08:57:10 sc59 vmkernel: 368:19:27:33.600 cpu7:1039)WARNING: ScsiPath: 3187: Plugin 'legacyMP' had an error (Not supported) while claiming path 'vmhba1:C0:T288:L0'.Skipping the path. Any ideas what the problem is?

    Read the article

  • getting Thunderbird rescan imap folder

    - by asdmin
    Since I got an external program (imapfilter) modifying my imap folder, thunderbird keeps loosing track of new messages. Messages are moved upon arrival in sub-folders, making Thunderbird unable keep tracking them - therefore I have no clue which folders to look for new messages, and newly created folders (even I subscribe them after creation) does not show up until I restart the mail client. Is there any extension or setting for Thunderbird which I could use to trigger re-scanning my folder tree? Please don't waste time on advices like restarting Thunderbird: takes a great amount of time, or "use Evolution (or any other mail client)", or use internal mail filters: they are not sophisticated enough or procmail/fetchmail: I'm arranging a remote imap server for good EXTENSION 1: even folders can be created in the background, without Thunderbird would know it has been created.

    Read the article

  • Image Rescan issue

    - by user1296361
    I am working on a code that could scan the specific folder, when picture is taken, I used the following code: Intent intent = new Intent(); intent.setType("image/*"); //intent.setAction(Intent.ACTION_GET_CONTENT); sendBroadcast(new Intent(Intent.ACTION_MEDIA_MOUNTED, Uri.parse("file://sdcard/ghost/" + Environment.getExternalStorageDirectory()))); startActivityForResult( Intent.createChooser(intent, "Select Picture"), 0); It works fine, but when I exit the app and start the app again, scan is not performed, what could be the issue? Help needed!!!

    Read the article

  • Using Diskpart in a PowerShell script won't allow script to reuse drive letter

    - by Kyle
    I built a script that mounts (attach) a VHD using Diskpart, cleans out some system files and then unmounts (detach) it. It uses a foreach loop and is suppose to clean multiple VHD using the same drive letter. However, after the 1st VHD it fails. I also noticed that when I try to manually attach a VHD with diskpart, diskpart succeeds, the Disk Manager shows the disk with the correct drive letter, but within the same PoSH instance I can not connect (set-location) to that drive. If I do a manual diskpart when I 1st open PoSH I can attach and detach all I want and I get the drive letter every time. Is there something I need to do to reset diskpart in the script? Here's a snippet of the script I'm using. function Mount-VHD { [CmdletBinding()] param ( [Parameter(Position=0,Mandatory=$true,ValueFromPipeline=$false)] [string]$Path, [Parameter(Position=1,Mandatory=$false,ValueFromPipeline=$false)] [string]$DL, [string]$DiskpartScript = "$env:SystemDrive\DiskpartScript.txt", [switch]$Rescan ) begin { function InvokeDiskpart { Diskpart.exe /s $DiskpartScript } ## Validate Operating System Version ## if (Get-WmiObject win32_OperatingSystem -Filter "Version < '6.1'") {throw "The script operation requires at least Windows 7 or Windows Server 2008 R2."} } process{ ## Diskpart Script Content ## Here-String statement purposefully not indented ## @" $(if ($Rescan) {'Rescan'}) Select VDisk File="$Path" `nAttach VDisk Exit "@ | Out-File -FilePath $DiskpartScript -Encoding ASCII -Force InvokeDiskpart Start-Sleep -Seconds 3 @" Select VDisk File="$Path"`nSelect partition 1 `nAssign Letter="$DL" Exit "@ | Out-File -FilePath $DiskpartScript -Encoding ASCII -Force InvokeDiskpart } end { Remove-Item -Path $DiskpartScript -Force ; "" Write-Host "The VHD ""$Path"" has been successfully mounted." ; "" } } function Dismount-VHD { [CmdletBinding()] param ( [Parameter(Position=0,Mandatory=$true,ValueFromPipeline=$false)] [string]$Path, [switch]$Remove, [switch]$NoConfirm, [string]$DiskpartScript = "$env:SystemDrive\DiskpartScript.txt", [switch]$Rescan ) begin { function InvokeDiskpart { Diskpart.exe /s $DiskpartScript } function RemoveVHD { switch ($NoConfirm) { $false { ## Prompt for confirmation to delete the VHD file ## "" ; Write-Warning "Are you sure you want to delete the file ""$Path""?" $Prompt = Read-Host "Type ""YES"" to continue or anything else to break" if ($Prompt -ceq 'YES') { Remove-Item -Path $Path -Force "" ; Write-Host "VHD ""$Path"" deleted!" ; "" } else { "" ; Write-Host "Script terminated without deleting the VHD file." ; "" } } $true { ## Confirmation prompt suppressed ## Remove-Item -Path $Path -Force "" ; Write-Host "VHD ""$Path"" deleted!" ; "" } } } ## Validate Operating System Version ## if (Get-WmiObject win32_OperatingSystem -Filter "Version < '6.1'") {throw "The script operation requires at least Windows 7 or Windows Server 2008 R2."} } process{ ## DiskPart Script Content ## Here-String statement purposefully not indented ## @" $(if ($Rescan) {'Rescan'}) Select VDisk File="$Path"`nDetach VDisk Exit "@ | Out-File -FilePath $DiskpartScript -Encoding ASCII -Force InvokeDiskpart Start-Sleep -Seconds 10 } end { if ($Remove) {RemoveVHD} Remove-Item -Path $DiskpartScript -Force ; "" } }

    Read the article

  • Use hotplug and turn on/off PCI device for replacing NIC

    - by Ryota Hashimoto
    How can I turn off the PCI slots and change the device (especially NIC) without shutting the server down? I found a similar question (How do I turn off PCI devices?) but there are no /sys/bus/pci/slot and no files in /sys/bus/pci/slots. I'm using 12.04 LTS. $ uname -a Linux d1-c1-r1-p1 3.2.0-38-generic #61-Ubuntu SMP Tue Feb 19 12:18:21 UTC 2013 x86_64 x86_64 x86_64 GNU/Linux $ lspci | grep Eth 04:00.0 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 04:00.1 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 09:00.0 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01) 09:00.1 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01) $ ls /sys/bus/pci/ devices/ drivers_probe slots/ drivers/ rescan uevent drivers_autoprobe resource_alignment $ ls /sys/bus/pci/devices/0000\:04\:00.0/ broken_parity_status driver modalias rescan subsystem class enable msi_bus reset subsystem_device config firmware_node net resource subsystem_vendor consistent_dma_mask_bits irq numa_node resource0 uevent device local_cpulist power resource2 vendor dma_mask_bits local_cpus remove resource3

    Read the article

  • Add Mirror for volumes other than the last one in Windows 7 (disk "not up-to-date")

    - by rakslice
    I'm using Windows 7 x64 Ultimate. I have an existing 4TB disk with 3 NTFS volumes, a new 3TB blank disk, and I'm trying to mirror the volumes onto the new disk. My Windows install is on an SSD which is Disk 0. The 4TB disk with volumes is Disk 1, and the new blank disk is Disk 2. I can add a mirror successfully for the last volume, but when I try to add a mirror for the first volume I immediately get errors (see below). Is there something I special I need to do to add a mirror for a volume other than the last one? More info: I opened Disk Management, right-clicked on the first volume on the existing disk, went to Add Mirror, and selected the new disk. The first time I did this I was prompted to convert the new disk to a Dynamic Disk, which I approved. Subsequently I got a message: The operation failed to complete because the Disk Management console view is not up-to-date. Refresh the view by using the refresh task. If the problem persists close the Disk Management console, then restart Disk Management or restart the computer. I've refreshed disk management, restarted the computer, and converted the new disk to basic and back to dynamic, but I still get that error message. Looking around for suggestions of a workaround, I saw a suggestion to use the diskpart command line tool. Running diskpart from the Start Menu as Administrator, I did select volume 2 (the first volume I want to mirror) and then add disk 2 (the new disk), and received a somewhat similar error: Virtual Disk Service error: The disk's extent information is corrupted. DiskPart has referenced an object which is not up-to-date. Refresh the object by using the RESCAN command. If the problem persists exit DiskPart, then restart DiskPart or restart the computer. A rescan appears to be successful: DISKPART> select disk 2 Disk 2 is now the selected disk. DISKPART> rescan Please wait while DiskPart scans your configuration... DiskPart has finished scanning your configuration. but attempting to add the mirror again resulted in the same error. The only similar report I found online was this: http://www.sevenforums.com/hardware-devices/335780-unable-mirror-all-but-last-partition-drive.html Based on that I attempted to mirror the last volume on the disk to the new disk using diskpart, and that started successfully -- it is currently resynchronizing. More Background: In the course of dealing with a failing 3TB hard drive, I bought a replacement 4TB drive and installed it, then copied the partitions from the failing drive to it using Minitool Partition Wizard Home, and then removed the failing drive and was up and running again normally. Now I've received a warranty replacement for the failing drive, and installed it, and now I'm attempting to mirror my partitions to it.

    Read the article

  • How do I remove a USB drive's write protection?

    - by nate
    I have a SanDisk Cruser Blade USB stick that suddenly seems to be write protected. I tried running DiskPart but after I write the command "attributes disk clear readonly" it displays this: Microsoft DiskPart version 5.1.3565 ADD - Add a mirror to a simple volume. ACTIVE - Marks the current basic partition as an active boot partition. ASSIGN - Assign a drive letter or mount point to the selected volume. BREAK - Break a mirror set. CLEAN - Clear the configuration information, or all information, off the disk. CONVERT - Converts between different disk formats. CREATE - Create a volume or partition. DELETE - Delete an object. DETAIL - Provide details about an object. EXIT - Exit DiskPart EXTEND - Extend a volume. HELP - Prints a list of commands. IMPORT - Imports a disk group. LIST - Prints out a list of objects. INACTIVE - Marks the current basic partition as an inactive partition. ONLINE - Online a disk that is currently marked as offline. REM - Does nothing. Used to comment scripts. REMOVE - Remove a drive letter or mount point assignment. REPAIR - Repair a RAID-5 volume. RESCAN - Rescan the computer looking for disks and volumes. RETAIN - Place a retainer partition under a simple volume. SELECT - Move the focus to an object. It's like when you type help at the DiskPart prompt, so how do I get past this? This problem started when I plugged the stick into a laptop which had viruses, if that's any help.

    Read the article

  • Ubuntu-one syncs single files, but not directories [closed]

    - by Luiz Cláudio Duarte
    I'm using Ubuntu 10.10, fully updated. I have tried to sync my ~/Documents and ~/Pictures folders; U1 replicates the directory structure, but no files are uploaded. Next I tried to sync a single file inside ~/Ubuntu One and it was synced. Then I tried to put a directory inside ~/Ubuntu One and, again, the directory structure was replicated, but no files were synced. All the files have the "syncing" icon, however. The latest syncdaemon.log is below: 2011-03-30 07:41:50,752 - ubuntuone.SyncDaemon.fsm - INFO - loading updated metadata 2011-03-30 07:41:55,081 - ubuntuone.SyncDaemon.fsm - INFO - initialized: idx_path: 266, idx_node_id: 266, shares: 1 2011-03-30 07:41:55,082 - ubuntuone.SyncDaemon.GeneralINotProc - INFO - Ignoring files: ['\\A#.*\\Z', '\\A.*~\\Z', '\\A.*\\.py[oc]\\Z', '\\A.*\\.sw[nopx]\\Z', '\\A.*\\.swpx\\Z', '\\A\\..*\\.tmp\\Z'] 2011-03-30 07:41:55,083 - ubuntuone.SyncDaemon.HQ - INFO - HashQueue: _hasher started 2011-03-30 07:41:55,902 - ubuntuone.SyncDaemon.DBus - INFO - DBusInterface initialized. 2011-03-30 07:41:55,903 - ubuntuone.SyncDaemon.Main - INFO - Using '/home/l_claudius/Ubuntu One' as root dir 2011-03-30 07:41:55,903 - ubuntuone.SyncDaemon.Main - INFO - Using '/home/l_claudius/.local/share/ubuntuone/syncdaemon' as data dir 2011-03-30 07:41:55,903 - ubuntuone.SyncDaemon.Main - INFO - Using '/home/l_claudius/.local/share/ubuntuone/shares' as shares root dir 2011-03-30 07:41:55,903 - ubuntuone.SyncDaemon.Main - NOTE - ---- MARK (state: <State: 'INIT' (queues IDLE connection 'Not User Not Network')>; queues: metadata: 0; content: 0; hash: 0, fsm-cache: hit=1 miss=266) ---- 2011-03-30 07:41:55,904 - ubuntuone.SyncDaemon.Main - NOTE - Local rescan starting... 2011-03-30 07:41:55,904 - ubuntuone.SyncDaemon.local_rescan - INFO - start scan all volumes 2011-03-30 07:41:55,906 - ubuntuone.SyncDaemon.local_rescan - INFO - processing trash 2011-03-30 07:41:56,044 - ubuntuone.SyncDaemon.local_rescan - INFO - processing move limbo 2011-03-30 07:41:56,491 - ubuntuone.SyncDaemon.Main - NOTE - Local rescan finished! 2011-03-30 07:41:56,492 - ubuntuone.SyncDaemon.Main - INFO - hash queue empty. We are ready! 2011-03-30 07:42:15,583 - ubuntuone.SyncDaemon.DBus - INFO - u'CredentialsFound': callbacking with credentials (token_name: None). 2011-03-30 07:42:15,584 - ubuntuone.SyncDaemon.DBus - INFO - connect: credential request was successful, pushing SYS_USER_CONNECT. 2011-03-30 07:42:15,617 - ubuntuone.SyncDaemon.ActionQueue - INFO - Connection started to host fs-1.one.ubuntu.com, port 443. 2011-03-30 07:42:15,977 - ubuntuone.SyncDaemon.ActionQueue - INFO - Connection made. 2011-03-30 07:42:15,978 - ubuntuone.SyncDaemon.StorageClient - INFO - Connection made. 2011-03-30 07:42:16,581 - ubuntuone.SyncDaemon.ActionQueue - INFO - The request 'protocol_version' finished OK. 2011-03-30 07:42:16,774 - ubuntuone.SyncDaemon.ActionQueue - INFO - The request 'caps_raising_if_not_accepted' finished OK. 2011-03-30 07:42:16,966 - ubuntuone.SyncDaemon.ActionQueue - INFO - The request 'caps_raising_if_not_accepted' finished OK. 2011-03-30 07:42:17,722 - ubuntuone.SyncDaemon.ActionQueue - INFO - The request 'oauth_authenticate' finished OK. 2011-03-30 07:42:17,723 - ubuntuone.SyncDaemon.ActionQueue - NOTE - Session ID: '563bc960-35fa-4f44-b9b6-125819656dc3' 2011-03-30 07:42:19,258 - ubuntuone.SyncDaemon.ActionQueue - INFO - The request 'list_volumes' finished OK. 2011-03-30 07:43:55,903 - ubuntuone.SyncDaemon.Main - NOTE - ---- MARK (state: <State: 'QUEUE_MANAGER' (queues IDLE connection 'With User With Network')>; queues: metadata: 0; content: 0; hash: 0, fsm-cache: hit=1059 miss=266) ---- 2011-03-30 07:45:55,903 - ubuntuone.SyncDaemon.Main - NOTE - ---- MARK (state: <State: 'QUEUE_MANAGER' (queues IDLE connection 'With User With Network')>; queues: metadata: 0; content: 0; hash: 0, fsm-cache: hit=1059 miss=266) ---- 2011-03-30 07:47:55,903 - ubuntuone.SyncDaemon.Main - NOTE - ---- MARK (state: <State: 'QUEUE_MANAGER' (queues IDLE connection 'With User With Network')>; queues: metadata: 0; content: 0; hash: 0, fsm-cache: hit=1059 miss=266) ---- 2011-03-30 07:49:55,903 - ubuntuone.SyncDaemon.Main - NOTE - ---- MARK (state: <State: 'QUEUE_MANAGER' (queues IDLE connection 'With User With Network')>; queues: metadata: 0; content: 0; hash: 0, fsm-cache: hit=1059 miss=266) ---- 2011-03-30 07:51:55,903 - ubuntuone.SyncDaemon.Main - NOTE - ---- MARK (state: <State: 'QUEUE_MANAGER' (queues IDLE connection 'With User With Network')>; queues: metadata: 0; content: 0; hash: 0, fsm-cache: hit=1059 miss=266) ----

    Read the article

  • How to deal with recursive dependencies between static libraries using the binutils linker?

    - by Jack Lloyd
    I'm porting an existing system from Windows to Linux. The build is structured with multiple static libraries. I ran into a linking error where a symbol (defined in libA) could not be found in an object from libB. The linker line looked like g++ test_obj.o -lA -lB -o test The problem of course being that by the time the linker finds it needs the symbol from libA, it has already passed it by, and does not rescan, so it simply errors out even though the symbol is there for the taking. My initial idea was of course to simply swap the link (to -lB -lA) so that libA is scanned afterwards, and any symbols missing from libB that are in libA are picked up. But then I find there is actually a recursive dependency between libA and libB! I'm assuming the Visual C++ linker handles this in some way (does it rescan by default?). Ways of dealing with this I've considered: Use shared objects. Unfortunately this is undesirable from the perspective of requiring PIC compliation (this is performance sensitive code and losing %ebx to hold the GOT would really hurt), and shared objects aren't needed. Build one mega ar of all of the objects, avoiding the problem. Restructure the code to avoid the recursive dependency (which is obviously the Right Thing to do, but I'm trying to do this port with minimal changes). Do you have other ideas to deal with this? Is there some way I can convince the binutils linker to perform rescans of libraries it has already looked at when it is missing a symbol?

    Read the article

  • Linux Fiber Channel Host Setup Basic

    - by Jim
    I've been googling for about 4 hours now with no luck. I am trying to setup a Linux server running Oracle Server 6.3 as a Fiber Channel host. And then connect it to a Dell Compellent Fibre Channel Host contain a 500GB Volume. The Oracle server itself contains two Brocade 815 FC HBAs. I've discovered their WWN(I think) via cat /sys/class/fc_host/host1/port_name 0x100000051efc3d85 cat /sys/class/fc_host/host2/port_name 0x100000051efc3d9f The next part is where I am at a loss. I've used iSCSI before...is FC the same deal where you have an initiator and a target? If so where do I specific that in linux? I'm also new to Fiber Channel as a protocol, so i am unsure what is needed to make a transaction? WWN and port ID? Similar to IP:Port combination in the Ethernet world. I've read alot regarding using systool, multipath, fc_transport commands, however none of these is recognized as a valid command from Oracle Server 6.3 Appreciate the guidance and assistance. I installed sccsi-target-utils and can now run rescan-scsi-bus and sg_map -x. rescan-scsi-bus.sh -l -w -r Host adapter 0 (megaraid_sas) found. Host adapter 1 ((null)) found. Host adapter 2 ((null)) found. Host adapter 3 (ata_piix) found. Host adapter 4 (ata_piix) found. Scanning SCSI subsystem for new devices and remove devices that have disappeared Scanning host 0 for SCSI target IDs 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15, LUNs 0 1 2 3 4 5 6 7 Scanning for device 0 2 0 0 .... OLD: Host: scsi0 Channel: 02 Id: 00 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning for device 0 2 1 0 ... OLD: Host: scsi0 Channel: 02 Id: 01 Lun: 00 Vendor: DELL Model: PERC H700 Rev: 2.30 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 1 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 1 0 3 1 ... OLD: Host: scsi1 Channel: 00 Id: 03 Lun: 01 Vendor: COMPELNT Model: Compellent Vol Rev: 0505 Type: Direct-Access ANSI SCSI revision: 05 Scanning host 2 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning host 3 for all SCSI target IDs, LUNs 0 1 2 3 4 5 6 7 Scanning for device 3 0 0 0 ... REM: Host: scsi3 Channel: 00 Id: 00 Lun: 00 DEL: Vendor: TEAC Model: DVD-ROM DV-28SW Rev: R.2A Type: CD-ROM ANSI SCSI revision: 05 Scanning host 4 channels 0 for SCSI target IDs 0, LUNs 0 1 2 3 4 5 6 7 0 new device(s) found. 1 device(s) removed. and sg_map -x /dev/sg0 0 0 32 0 13 /dev/sg1 0 2 0 0 0 /dev/sda /dev/sg2 0 2 1 0 0 /dev/sdb /dev/sg4 1 0 3 1 0 /dev/sdc I'm not sure what this all means...

    Read the article

  • Extend partition windows powershell

    - by user128364
    I want to create a Windows Powershell script to extend my partition through WMI (remotely), IP Address of my host id 10.10.10.10 $pass = convertto-securestring "abc123#" -asplaintext -force $mycred = new-object -typename System.Management.Automation.PSCredential -argumentlist "10.10.10.10\Administrator",$pass Invoke-Command -ComputerName 10.10.10.10 -Credential $myCred -ScriptBlock {"rescan","select volume 2","extend" | diskpart} Do we have any method with use of Invoke-Wmimethod

    Read the article

  • Problem with sound in Kubuntu 12.10

    - by Mihkel
    I'm really enjoying Kubuntu 12.10 experience, but the problem starts with sound. It wasn't here before, but today sound sounds garbled and echoed and wrong. It happens in Audacity and VLC. It doesn't happen when I test the sound devices nor when I use Amarok to play the music files (but come on, who uses Amarok to listen to a random music file, it's much more natural to use VLC for that ;-) ) Kubuntu/Phonon recognizes 2 sound devices: 1) RV770 HDMI Audio [Radeon HD 4850/4870] Digital Stereo [HDMI] 2) Built-in Audio Analog Stereo I know it has to use the second option, and it probably does, but that's not the case. What I did find out was that I had to rescan for audio devices in Audacity (and probably select "sysdefault") for it to sound normal. Why does it happen? I've tried following some other questions, but well.

    Read the article

  • hp ProLiant DL380 G6 server error code: 347 of array controller

    - by alhaythum
    I have got a bran new hp ProLiant DL380 G6 server with embedded smart array P410i controller, I got 164 GB SATA drives and wanted to change them with 300 GB SATA drives before installation. Now, we replace the drives and begin the configuration with the hp DVD and begin; when we reach the point that we want to save the configurations, an error message appears: "The operation has failed with an unknown error, please restart the application and attempt the operation again" When using Rescan System, this error message appears: "Status Alerts - Smart Array P410i in Embedded Slot Warning Status Message Code Description 347 The cache for Smart Array P410i Embedded Slot is not configured" We return back to the 164 GB SATA drives and the message just keeps appearing again. Any help please.

    Read the article

  • Upgrading a PERC h310 to a PERC H710 mini RAID controller on a Dell R620

    - by Gregg Leventhal
    I have an ESXi 5.0 Free license host using an internal Datastore (RAID 5, 5 Disk) that was configured with a Dell PERC h310 RAID controller. The disk performance was very poor, so I upgraded to the PERC H710 Mini. The IT Tech installed the controller and powered the host back on. I had to rescan the controller and the datastore appeared. Should any settings be changed in the RAID BIOS, or should the default settings be sufficient? Is they anything to be aware of when performing this type of upgrade in order to achieve the maximum performance?

    Read the article

  • How to scale page size down in Adobe Acrobat X Pro?

    - by WilliamKF
    I scanned a document on a scanner at a friend's house and the pdf ended up being 35 inches by 45 inches in size. I think this the cause of the trouble had for the person I sent it to, they get the error "insufficient image". How can I scale this down in Adobe Acrobat X Pro to a normal 8.5x11 inch sheet so that I can see if that resolves their issue and I can share the document with them. I cannot rescan the document, as I no longer have it. Acrobat is running on Windows 7 OS. The scanner was an HP OfficeJet Pro L7650 All-in-one.

    Read the article

  • How do I make Linux recognize a new SATA /dev/sda drive I hot swapped in without rebooting?

    - by Philip Durbin
    Hot swapping out a failed SATA /dev/sda drive worked fine, but when I went to swap in a new drive, it wasn't recognized: [root@fs-2 ~]# tail -18 /var/log/messages May 5 16:54:35 fs-2 kernel: ata1: exception Emask 0x10 SAct 0x0 SErr 0x50000 action 0xe frozen May 5 16:54:35 fs-2 kernel: ata1: SError: { PHYRdyChg CommWake } May 5 16:54:40 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:54:45 fs-2 kernel: ata1: device not ready (errno=-16), forcing hardreset May 5 16:54:45 fs-2 kernel: ata1: soft resetting link May 5 16:54:50 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:54:55 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:54:55 fs-2 kernel: ata1: soft resetting link May 5 16:55:00 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:55:05 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:05 fs-2 kernel: ata1: soft resetting link May 5 16:55:10 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:55:40 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:40 fs-2 kernel: ata1: limiting SATA link speed to 1.5 Gbps May 5 16:55:40 fs-2 kernel: ata1: soft resetting link May 5 16:55:45 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:45 fs-2 kernel: ata1: reset failed, giving up May 5 16:55:45 fs-2 kernel: ata1: EH complete I tried a couple things to make the server find the new /dev/sda, such as rescan-scsi-bus.sh but they didn't work: [root@fs-2 ~]# echo "---" > /sys/class/scsi_host/host0/scan -bash: echo: write error: Invalid argument [root@fs-2 ~]# [root@fs-2 ~]# /root/rescan-scsi-bus.sh -l [snip] 0 new device(s) found. 0 device(s) removed. [root@fs-2 ~]# [root@fs-2 ~]# ls /dev/sda ls: /dev/sda: No such file or directory I ended up rebooting the server. /dev/sda was recognized, I fixed the software RAID, and everything is fine now. But for next time, how can I make Linux recognize a new SATA drive I have hot swapped in without rebooting? The operating system in question is RHEL5.3: [root@fs-2 ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.3 (Tikanga) The hard drive is a Seagate Barracuda ES.2 SATA 3.0-Gb/s 500-GB, model ST3500320NS. Here is the lscpi output: [root@fs-2 ~]# lspci 00:00.0 RAM memory: nVidia Corporation MCP55 Memory Controller (rev a2) 00:01.0 ISA bridge: nVidia Corporation MCP55 LPC Bridge (rev a3) 00:01.1 SMBus: nVidia Corporation MCP55 SMBus (rev a3) 00:02.0 USB Controller: nVidia Corporation MCP55 USB Controller (rev a1) 00:02.1 USB Controller: nVidia Corporation MCP55 USB Controller (rev a2) 00:04.0 IDE interface: nVidia Corporation MCP55 IDE (rev a1) 00:05.0 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.1 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.2 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:06.0 PCI bridge: nVidia Corporation MCP55 PCI bridge (rev a2) 00:08.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:09.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:0a.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0b.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0c.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0d.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0e.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0f.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 00:19.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:19.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:19.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:19.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 03:00.0 VGA compatible controller: Matrox Graphics, Inc. MGA G200e [Pilot] ServerEngines (SEP1) (rev 02) 04:00.0 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 04:00.1 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) Update: In perhaps a dozen cases, we've been forced to reboot servers because hot swap hasn't "just worked." Thanks for the answers to look more into the SATA controller. I've included the lspci output for the problematic system above (hostname: fs-2). I could still use some help understanding what exactly isn't supported hardware-wise in terms of hot swap for that system. Please let me know what other output besides lspci might be useful. The good news is that hot swap "just worked" today on one of our servers (hostname: www-1), which is very rare for us. Here is the lspci output: [root@www-1 ~]# lspci 00:00.0 RAM memory: nVidia Corporation MCP55 Memory Controller (rev a2) 00:01.0 ISA bridge: nVidia Corporation MCP55 LPC Bridge (rev a3) 00:01.1 SMBus: nVidia Corporation MCP55 SMBus (rev a3) 00:02.0 USB Controller: nVidia Corporation MCP55 USB Controller (rev a1) 00:02.1 USB Controller: nVidia Corporation MCP55 USB Controller (rev a2) 00:04.0 IDE interface: nVidia Corporation MCP55 IDE (rev a1) 00:05.0 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.1 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.2 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:06.0 PCI bridge: nVidia Corporation MCP55 PCI bridge (rev a2) 00:08.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:09.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:0b.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0c.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0f.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] HyperTransport Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Miscellaneous Control 00:18.4 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Link Control 00:19.0 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] HyperTransport Configuration 00:19.1 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Address Map 00:19.2 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] DRAM Controller 00:19.3 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Miscellaneous Control 00:19.4 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Link Control 03:00.0 VGA compatible controller: Matrox Graphics, Inc. MGA G200e [Pilot] ServerEngines (SEP1) (rev 02) 04:00.0 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 04:00.1 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 09:00.0 SCSI storage controller: LSI Logic / Symbios Logic SAS1064ET PCI-Express Fusion-MPT SAS (rev 04)

    Read the article

  • How do I make Linux recognize a new SATA /dev/sda drive I hot swapped in without rebooting?

    - by Philip Durbin
    Hot swapping out a failed SATA /dev/sda drive worked fine, but when I went to swap in a new drive, it wasn't recognized: [root@fs-2 ~]# tail -18 /var/log/messages May 5 16:54:35 fs-2 kernel: ata1: exception Emask 0x10 SAct 0x0 SErr 0x50000 action 0xe frozen May 5 16:54:35 fs-2 kernel: ata1: SError: { PHYRdyChg CommWake } May 5 16:54:40 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:54:45 fs-2 kernel: ata1: device not ready (errno=-16), forcing hardreset May 5 16:54:45 fs-2 kernel: ata1: soft resetting link May 5 16:54:50 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:54:55 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:54:55 fs-2 kernel: ata1: soft resetting link May 5 16:55:00 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:55:05 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:05 fs-2 kernel: ata1: soft resetting link May 5 16:55:10 fs-2 kernel: ata1: link is slow to respond, please be patient (ready=0) May 5 16:55:40 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:40 fs-2 kernel: ata1: limiting SATA link speed to 1.5 Gbps May 5 16:55:40 fs-2 kernel: ata1: soft resetting link May 5 16:55:45 fs-2 kernel: ata1: SRST failed (errno=-16) May 5 16:55:45 fs-2 kernel: ata1: reset failed, giving up May 5 16:55:45 fs-2 kernel: ata1: EH complete I tried a couple things to make the server find the new /dev/sda, such as rescan-scsi-bus.sh but they didn't work: [root@fs-2 ~]# echo "---" > /sys/class/scsi_host/host0/scan -bash: echo: write error: Invalid argument [root@fs-2 ~]# [root@fs-2 ~]# /root/rescan-scsi-bus.sh -l [snip] 0 new device(s) found. 0 device(s) removed. [root@fs-2 ~]# [root@fs-2 ~]# ls /dev/sda ls: /dev/sda: No such file or directory I ended up rebooting the server. /dev/sda was recognized, I fixed the software RAID, and everything is fine now. But for next time, how can I make Linux recognize a new SATA drive I have hot swapped in without rebooting? The operating system in question is RHEL5.3: [root@fs-2 ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.3 (Tikanga) The hard drive is a Seagate Barracuda ES.2 SATA 3.0-Gb/s 500-GB, model ST3500320NS. Here is the lscpi output: [root@fs-2 ~]# lspci 00:00.0 RAM memory: nVidia Corporation MCP55 Memory Controller (rev a2) 00:01.0 ISA bridge: nVidia Corporation MCP55 LPC Bridge (rev a3) 00:01.1 SMBus: nVidia Corporation MCP55 SMBus (rev a3) 00:02.0 USB Controller: nVidia Corporation MCP55 USB Controller (rev a1) 00:02.1 USB Controller: nVidia Corporation MCP55 USB Controller (rev a2) 00:04.0 IDE interface: nVidia Corporation MCP55 IDE (rev a1) 00:05.0 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.1 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.2 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:06.0 PCI bridge: nVidia Corporation MCP55 PCI bridge (rev a2) 00:08.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:09.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:0a.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0b.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0c.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0d.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0e.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0f.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 00:19.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:19.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:19.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:19.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 03:00.0 VGA compatible controller: Matrox Graphics, Inc. MGA G200e [Pilot] ServerEngines (SEP1) (rev 02) 04:00.0 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 04:00.1 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) Update: In perhaps a dozen cases, we've been forced to reboot servers because hot swap hasn't "just worked." Thanks for the answers to look more into the SATA controller. I've included the lspci output for the problematic system above (hostname: fs-2). I could still use some help understanding what exactly isn't supported hardware-wise in terms of hot swap for that system. Please let me know what other output besides lspci might be useful. The good news is that hot swap "just worked" today on one of our servers (hostname: www-1), which is very rare for us. Here is the lspci output: [root@www-1 ~]# lspci 00:00.0 RAM memory: nVidia Corporation MCP55 Memory Controller (rev a2) 00:01.0 ISA bridge: nVidia Corporation MCP55 LPC Bridge (rev a3) 00:01.1 SMBus: nVidia Corporation MCP55 SMBus (rev a3) 00:02.0 USB Controller: nVidia Corporation MCP55 USB Controller (rev a1) 00:02.1 USB Controller: nVidia Corporation MCP55 USB Controller (rev a2) 00:04.0 IDE interface: nVidia Corporation MCP55 IDE (rev a1) 00:05.0 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.1 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:05.2 IDE interface: nVidia Corporation MCP55 SATA Controller (rev a3) 00:06.0 PCI bridge: nVidia Corporation MCP55 PCI bridge (rev a2) 00:08.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:09.0 Bridge: nVidia Corporation MCP55 Ethernet (rev a3) 00:0b.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0c.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:0f.0 PCI bridge: nVidia Corporation MCP55 PCI Express bridge (rev a3) 00:18.0 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] HyperTransport Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Miscellaneous Control 00:18.4 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Link Control 00:19.0 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] HyperTransport Configuration 00:19.1 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Address Map 00:19.2 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] DRAM Controller 00:19.3 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Miscellaneous Control 00:19.4 Host bridge: Advanced Micro Devices [AMD] K10 [Opteron, Athlon64, Sempron] Link Control 03:00.0 VGA compatible controller: Matrox Graphics, Inc. MGA G200e [Pilot] ServerEngines (SEP1) (rev 02) 04:00.0 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 04:00.1 PCI bridge: NEC Corporation uPD720400 PCI Express - PCI/PCI-X Bridge (rev 06) 09:00.0 SCSI storage controller: LSI Logic / Symbios Logic SAS1064ET PCI-Express Fusion-MPT SAS (rev 04)

    Read the article

  • Start daemon after specific samba share is mounted

    - by getack
    I have a homebrew headless NAS running 12.04. In it I have a bunch of disks that are presented as a samba share thanks to Greyhole. If I want to do anything to the files within this share, I must do it through greyhole so that everything is updated properly. Thus, the share must be mounted locally and then accessed from there if I want to work on the files from the local machine. I do this mounting automatically thanks to these instructions. I also have Deluge installed that takes care of all my torrenting needs. Deluge's default download location is in this share, so that all the downloads are immediately available to the rest of the network. Obviously for everything to work, the share must be mounted, otherwise Deluge is going to have a problem downloading to it. The problem is, it seems like Deluge is starting before the shares are mounted when the system boots. So downloading/seeding does not continue automatically after boot. I have to log in and force a manual rescan and start on each torrent otherwise all the torrents just hangs on the error. Is there a way I can make deluge start after the shares got properly mounted? I looked into Upstart's emits functionality but I cannot seem to get it to work properly. Any advice?

    Read the article

  • The tale of how the PowerShell CmdLets got installed with Azure SDK 1.4

    - by Enrique Lima
    I installed the Azure SDK 1.4 while rebuilding my laptop and ran the installation for the Windows Azure Service Management PowerShell CmdLets. Kicked off the installation script for the WASM PowerShell CmdLets by locating the path to which WASM PowerShell CmdLets was deployed to. Double clicked the startHere command. It will then open the WASM installation dialog. Click Next. Click Next. Notice the red x next to the Azure SDK 1.3, the problem is I have SDK 1.4 Here is the workaround, I go back to the location of the deployed WASM sources. Go into the setup path, then scripts>dependencies>check. Now, locate the CheckAzureSDK.ps1 file, and right-click, then edit. This is the content in the ps1 file, it check for the specific version of the Azure SDK, in this case, it is looking for version 1.3.11133.0038. We need for it to check for version 1.4.20227.1419 Now, save your ps1 file, go back to the open WASM install dialog, and click rescan. This time it should pass, then click next. A Command prompt window will appear, click any key. This completes the installation, click Close.

    Read the article

  • ESX3.5 Cluster & MD3000i -- Both servers see iSCSI Targets, Only one server can use partition.

    - by GruffTech
    Alright. First and foremost, Warning. This is a bigger-then-normal question. I like to be thorough and try to eliminate all possible "easymode" answers, as well as give everyone a feel of what i've tried. I've included several images of our setup and the problem it is having.. TLDR Version: So I've followed the guides located here: ESX Deployment Guide V1 this is the guide Dell has sent me to setup two ESX3.5 servers mounting a Dell MD3000i. It doesn't work. Both servers can't use the same storage partition on the MD3000. Both servers see it, but only one server can actually use it. (that server being whatever server created the partition on the target.) Both ESX servers are members of the Host Group. Full Version I have 2 ESX3.5 Servers (10.0.7.102, also called EPI2, and 10.0.7.103, also called EPI3.) connected to a iSCSI SAN Device (Dell MD3000i). Both ESX servers can "scan" the SAN and see the LUNS. Part One: MD3000i Storage On the MD3000i, Both servers are in my host group. I have two partitions, VM1 and VM2, both 1.6TB (vmware doesn't like anything past 2tb.) And you can even see that the ESX servers are targetting the MD3000 just fine. Part Two: The ESX Servers Figure 1. So as you can see above, Both ESX Servers (10.0.7.102 and 10.0.7.103) are able to see and scan the MD3000i SAN. Figure 2. Above is the storage both servers see. I created the storage partition on EPI2 (102). I then Extended the partition to include the second LUN for a grand total of 3.27 TB of storage. When i "rescan" on 103 (the server not mounting the partition), I get the below log in log/messages. Mar 11 10:41:18 epi3 kernel: scsi1: remove-single-device 0 0 0 failed, device busy(4). being the only line that grabs my attentions. (EPI3 is the server name) Mar 11 10:41:04 epi3 vmkiscsid[5436]: Connected to Discovery Address 192.168.130.101 Mar 11 10:41:04 epi3 vmkiscsid[5437]: Connected to Discovery Address 192.168.130.102 Mar 11 10:41:04 epi3 vmkiscsid[5438]: Connected to Discovery Address 192.168.131.101 Mar 11 10:41:04 epi3 vmkiscsid[5439]: Connected to Discovery Address 192.168.131.102 Mar 11 10:41:17 epi3 kernel: scsi singledevice 2 0 0 0 Mar 11 10:41:17 epi3 kernel: Vendor: DELL Model: MD3000i Rev: 0735 Mar 11 10:41:17 epi3 kernel: Type: Direct-Access ANSI SCSI revision: 05 Mar 11 10:41:17 epi3 kernel: VMWARE SCSI Id: Supported VPD pages for sdb : 0x0 0x80 0x83 0x85 0x86 0x87 0xc0 0xc1 0xc2 0xc3 0xc4 0xc8 0xc9 0xca 0xd0 Mar 11 10:41:17 epi3 kernel: VMWARE SCSI Id: Device id info for sdb: 0x1 0x3 0x0 0x10 0x60 0x1 0xe4 0xf0 0x0 0x1a 0x1a 0xa2 0x0 0x0 0x15 0xe2 0x4d 0x75 0xf6 0x99 0x53 0x98 0x0 0x54 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x2c 0x74 0x2c 0x30 0x78 0x30 0x30 0x30 0x31 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x32 0x0 0x0 0x0 0x51 0x94 0x0 0x4 0x0 0x0 0x80 0x1 0x53 0xa8 0x0 0x44 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x0 0x0 0x0 0x0 Mar 11 10:41:17 epi3 kernel: VMWARE SCSI Id: Id for sdb 0x60 0x01 0xe4 0xf0 0x00 0x1a 0x1a 0xa2 0x00 0x00 0x15 0xe2 0x4d 0x75 0xf6 0x99 0x4d 0x44 0x33 0x30 0x30 0x30 Mar 11 10:41:17 epi3 kernel: VMWARE: Unique Device attached as scsi disk sdb at scsi2, channel 0, id 0, lun 0 Mar 11 10:41:17 epi3 kernel: Attached scsi disk sdb at scsi2, channel 0, id 0, lun 0 Mar 11 10:41:17 epi3 kernel: scan_scsis starting finish Mar 11 10:41:17 epi3 kernel: SCSI device sdb: 3509329920 512-byte hdwr sectors (1797751 MB) Mar 11 10:41:17 epi3 kernel: sdb: sdb1 Mar 11 10:41:17 epi3 kernel: scan_scsis done with finish Mar 11 10:41:17 epi3 kernel: scsi singledevice 2 0 0 1 Mar 11 10:41:17 epi3 kernel: Vendor: DELL Model: MD3000i Rev: 0735 Mar 11 10:41:17 epi3 kernel: Type: Direct-Access ANSI SCSI revision: 05 Mar 11 10:41:18 epi3 kernel: VMWARE SCSI Id: Supported VPD pages for sdc : 0x0 0x80 0x83 0x85 0x86 0x87 0xc0 0xc1 0xc2 0xc3 0xc4 0xc8 0xc9 0xca 0xd0 Mar 11 10:41:18 epi3 kernel: VMWARE SCSI Id: Device id info for sdc: 0x1 0x3 0x0 0x10 0x60 0x1 0xe4 0xf0 0x0 0x1a 0x1a 0x86 0x0 0x0 0xd 0xb7 0x4d 0x75 0xf2 0x77 0x53 0x98 0x0 0x54 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x2c 0x74 0x2c 0x30 0x78 0x30 0x30 0x30 0x31 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x32 0x0 0x0 0x0 0x51 0x94 0x0 0x4 0x0 0x0 0x80 0x1 0x53 0xa8 0x0 0x44 0x69 0x71 0x6e 0x2e 0x31 0x39 0x38 0x34 0x2d 0x30 0x35 0x2e 0x63 0x6f 0x6d 0x2e 0x64 0x65 0x6c 0x6c 0x3a 0x70 0x6f 0x77 0x65 0x72 0x76 0x61 0x75 0x6c 0x74 0x2e 0x36 0x30 0x30 0x31 0x65 0x34 0x66 0x30 0x30 0x30 0x31 0x61 0x31 0x61 0x61 0x32 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x30 0x34 0x37 0x39 0x30 0x36 0x32 0x32 0x65 0x0 0x0 0x0 0x0 Mar 11 10:41:18 epi3 kernel: VMWARE SCSI Id: Id for sdc 0x60 0x01 0xe4 0xf0 0x00 0x1a 0x1a 0x86 0x00 0x00 0x0d 0xb7 0x4d 0x75 0xf2 0x77 0x4d 0x44 0x33 0x30 0x30 0x30 Mar 11 10:41:18 epi3 kernel: VMWARE: Unique Device attached as scsi disk sdc at scsi2, channel 0, id 0, lun 1 Mar 11 10:41:18 epi3 kernel: Attached scsi disk sdc at scsi2, channel 0, id 0, lun 1 Mar 11 10:41:18 epi3 kernel: scan_scsis starting finish Mar 11 10:41:18 epi3 kernel: SCSI device sdc: 3509329920 512-byte hdwr sectors (1797751 MB) Mar 11 10:41:18 epi3 kernel: sdc: sdc1 Mar 11 10:41:18 epi3 kernel: scan_scsis done with finish Mar 11 10:41:18 epi3 kernel: scsi1: remove-single-device 0 0 0 failed, device busy(4). Mar 11 10:41:18 epi3 kernel: scsi singledevice 1 0 0 0 Things I've Tried: Removing iSCSI targets from only 103, disabling iSCSI, rebooting, enabled iSCSI, re-adding targets, rescan. Same result. Removing partition on 102, Formatted partition on 103 instead. Same result, except flipped. 103 can use storage, 102 can not. Starting Over. Removing all iSCSI Targets on both ESX Boxes, disabling iSCSI, turning off the firewall for iSCSI, rebooting ESX. Then on the MD3000, Removed the Host Group, Removed the Host-to-Virtual Mappings, Restarted the SAN. Followed the Documentation again, same result. Both servers see the storage, but only one server can use it. Disabling and Re-enabling VMware DRS and HA. Same result. Flat-out turning off VMware DRS and HA, and doing the "start over" step to see if maybe that borked it. Same Result. I'm kinda loosing my mind here, Everything i read online says "just partition it and if the ESX boxes can see the targets, it just works".... well crap. Any ideas, any other things to try? Can anyone atleast point me in the right direction? I'm really tired of working from 1am til 4am (our maintenance hours)

    Read the article

  • Injecting an XML fragment into the current document from an external file

    - by makenai
    I'm currently parsing an XML file using REXML and trying to come up with a way of inserting an XML fragment from an internal file. Currently, I'm using some logic like the following: doc.elements.each('//include') do |element| handleInclude( element ) end def handleInclude( element ) if filename = element.attributes['file'] data = File.open( filename ).read doc = REXML::Document.new( data ) element.parent.replace_child( element, doc ) end end Where my XML looks like the following: <include file="test.xml" /> But this seems a little bit clunky, and I'm worried that REXML might not always parse XML fragments correctly due to absence of a proper root node in some cases. Is there a better way of doing this? Concern #2: REXML seems not to pick up my changes after I replace elements. For example, after making a change: doc.elements.each('rootNode/*') do |element| end ..picks up neither the original element I replaced, nor the one I replaced it with. Is there some trick to getting REXML to rescan its' tree?

    Read the article

  • Forcing Windows to re-scan for drivers

    - by Martin
    As part of our software's installation, we install drivers for a required 3rd party hardware component. Currently it's up to the user to manually scan for their hardware's drivers once our installation is completed. Is there an easy way to get Windows to automatically look for the drivers we installed? If so, how does it work? Do we need to tell the OS for which hardware device we have drivers, or just that we have drivers in a certain location? Or can we just install the drivers to System32 folder and trigger a driver rescan?

    Read the article

  • git destroyed my changes

    - by mare
    I made a commit of my repository a week ago but never actually pushed it to the remote at github, which I did today. However, in the time from my commit I made many changes to the source. But just the initial commit was pushed to remote and while doing it, it also overwrote my local files. What can I do to get back my current files?? For better understanding, this is what I've done: Created new VS project and created a new git repository in it, Performed an initial scan, stage and commit but without adding a remote and performing a push, Worked on files for a week, (Today) Forgot to perform rescan, new stage and commit and just created new GitHub repository and performed this: git remote add origin [email protected]:myaccount/webshop.git git push origin master Now the files in GitHub repository are the ones from inital commit and those were also copied over my current files, so I'm in the initial commit stage now locally too, which is awful. Help appreciated