  • /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID

    - by user1495181
    using ubuntu with net-snmp snmp work but in sys.log i see a lot of errors about snmpd.conf snmpd.conf: rwcommunity community 10.0.0.1 rwcommunity community 10.0.0.2 agentAddress udp:10.0.0.1:161 view systemonly included .1.3.6.1.2.1.1 view systemonly included .1.3.6.1.2.1.25.1 # Default access to basic system info rocommunity public default -V systemonly rouser authOnlyUser sysLocation Sitting on the Dock of the Bay sysContact Me <[email protected]> sysServices 72 proc mountd proc ntalkd 4 proc sendmail 10 1 disk / 10000 disk /var 5% includeAllDisks 10% load 12 10 5 trapsink localhost public iquerySecName internalUser rouser internalUser defaultMonitors yes linkUpDownNotifications yes master agentx errors: Sep 12 16:35:00 test snmpd[5485]: payload OID: prNames Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: prNames Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: payload OID: prErrMessage Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: prErrMessage Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: trigger OID: prErrorFlag Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown monitor OID Sep 12 16:35:00 test snmpd[5485]: payload OID: memErrorName Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: memErrorName Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: payload OID: memSwapErrorMsg Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: memSwapErrorMsg Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: trigger OID: memSwapError Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown monitor OID Sep 12 16:35:00 test snmpd[5485]: payload OID: extNames Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: extNames Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: payload OID: extOutput Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: extOutput Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: trigger OID: extResult Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown monitor OID Sep 12 16:35:00 test snmpd[5485]: payload OID: dskPath Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: dskPath Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: payload OID: dskErrorMsg Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: dskErrorMsg Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: trigger OID: dskErrorFlag Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown monitor OID Sep 12 16:35:00 test snmpd[5485]: payload OID: laNames Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: laNames Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: payload OID: laErrMessage Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: laErrMessage Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: trigger OID: laErrorFlag Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown monitor OID Sep 12 16:35:00 test snmpd[5485]: payload OID: fileName Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: fileName Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: payload OID: fileErrorMsg Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: fileErrorMsg Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: trigger OID: fileErrorFlag Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown monitor OID Sep 12 16:35:00 test snmpd[5485]: payload OID: snmperrErrMessage Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown payload OID Sep 12 16:35:00 test snmpd[5485]: Unknown payload OID: snmperrErrMessage Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: Unknown payload OID Sep 12 16:35:00 test snmpd[5485]: trigger OID: snmperrErrorFlag Sep 12 16:35:00 test snmpd[5485]: /usr/local/share/snmp/snmpd.conf: line 5: Error: unknown monitor OID Sep 12 16:35:00 test snmpd[5485]: Turning on AgentX master support. Sep 12 16:35:00 test snmpd[5485]: net-snmp: 33 error(s) in config file(s)

    Read the article

  • snmpd agent sends duplicate traps

    - by jsnmp
    I am on Ubuntu 10.04.4 LTS, and I cannot upgrade to a higher version. I have installed the snmpd agent (NET-SNMP version 5.4.2.1) with an apt-get install snmpd command. When an event occurs which sends a trap, two traps are sent for each such event instead of one. For example, when I shut down the agent with command /etc/init.d/snmpd stop, two shutdown traps are sent to the destination host. If I then start back up the agent with command /etc/init.d/snmpd start, then two cold start traps are sent to the destination host. Is this a known issue? Is there a fix for this, or is there a configuration change that is needed to prevent the sending of the duplicate trap? These are the contents of the /etc/snmp/snmpd.conf file: rocommunity public authtrapenable 1 trap2sink <trap destination hostname> public These are the contents of the /etc/default/snmpd file: # This file controls the activity of snmpd and snmptrapd # MIB directories. /usr/share/snmp/mibs is the default, but # including it here avoids some strange problems. export MIBDIRS=/usr/share/snmp/mibs # snmpd control (yes means start daemon). SNMPDRUN=yes # snmpd options (use syslog, close stdin/out/err). SNMPDOPTS='-Ls3d -Lf /dev/null -u snmp -p /var/run/snmpd.pid -c /etc/snmp/snmpd.conf' # snmptrapd control (yes means start daemon). As of net-snmp version # 5.0, master agentx support must be enabled in snmpd before snmptrapd # can be run. See snmpd.conf(5) for how to do this. TRAPDRUN=no # snmptrapd options (use syslog). TRAPDOPTS='-Lsd -p /var/run/snmptrapd.pid' # create symlink on Debian legacy location to official RFC path SNMPDCOMPAT=yes

    Read the article

  • Getting hp-snmp-agents on HP ProLiant DL360 on Lenny working

    - by mark
    After receiving our HP ProLiant DL360 I'd like to integrate the machine into our Munin system and thus enable ProLiant specific information to be exposed via SNMP. I'm running Debian Lenny with kernel 2.6.26-2-vserver-amd64 . I've followed http://downloads.linux.hp.com/SDR/getting_started.html and the HP repository has been added to /etc/apt/sources.list.d/HP-ProLiantSupportPack.list . Setting up Lenny SNMP itself is not a problem, I configure it to have a public v1 community string to read all data and it works. I install hp-snmp-agents and run hpsnmpconfig and it adds additional lines to the top of /etc/snmp/snmpd.conf : dlmod cmaX /usr/lib64/libcmaX64.so snmpd gets restarted. Via lsof I can see that libcmaX64 was loaded and is used by snmpd, put I do not get any additional information out of snmp. I use snmpwalk -v 1 -c public ... and I can see many OIDs but I do not see the new ones I'd expect, most notably temperatures, fan speed and such. The OIDs I'm expecting are e.g. 1.3.6.1.4.1.232.6.2.6.8.1.4.1 , this is from the existing munin plugins from http://exchange.munin-monitoring.org/plugins/snmp__hp_temp/version/1 . snmpd[19007]: cmaX: Parsing shared as a type was unsucessful snmpd[19007]: cmaX: listening for subagents on port 25375 snmpd[19007]: cmaX: subMIB 1 handler has disconnected snmpd[19007]: cmaX: subMIB 2 handler has disconnected snmpd[19007]: cmaX: subMIB 3 handler has disconnected snmpd[19007]: cmaX: subMIB 5 handler has disconnected snmpd[19007]: cmaX: subMIB 6 handler has disconnected snmpd[19007]: cmaX: subMIB 8 handler has disconnected snmpd[19007]: cmaX: subMIB 9 handler has disconnected snmpd[19007]: cmaX: sent ColdStarts on ports 25376 to 25393 snmpd[19007]: cmaX: subMIB 10 handler has disconnected snmpd[19007]: cmaX: subMIB 11 handler has disconnected snmpd[19007]: cmaX: subMIB 14 handler has disconnected snmpd[19007]: cmaX: subMIB 15 handler has disconnected snmpd[19007]: cmaX: subMIB 16 handler has disconnected snmpd[19007]: cmaX: subMIB 21 handler has disconnected snmpd[19007]: cmaX: subMIB 22 handler has disconnected snmpd[19007]: cmaX: subMIB 23 handler has disconnected snmpd[19007]: cmaX: subMIB 1 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 2 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 3 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 5 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 6 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 8 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 9 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 10 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 11 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 14 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 15 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 16 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 21 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 22 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 23 will be sent on port 25376 to hp Advanced Server Management_Peer snmpd[19007]: cmaX: subMIB 18 handler has disconnected snmpd[19007]: cmaX: subMIB 18 will be sent on port 25393 to cpqnicd snmpd[19007]: NET-SNMP version 5.4.1 This doesn't look particular bad for me, it's just informational I guess. I've compared the walking OID output with and without the module and there's no difference in the OID served back at all. Are there any other prerequisites I'm missing? I've also noticed that from the time I installed hp-snmp-agents it adds a lot of additional daemons and that my load suddenly jumps to 1. I've uninstalled the package for now. Is this expected behavior?

    Read the article

  • snmpd dead but subsys locked

    - by Hina NMS
    Hi folks I have an NMS and a Client machine. I want the client to send traps to the NMS. I have been configuring the snmpd.conf file testing if i disable a process do i receive an alert or not. For the changes to reflect that were made in the conf file i restarted the snmpd daemon each time. The testing was going fine. All of a sudden when i restarted snmpd i recieved the error msg "snmpd dead but subsys locked". I googled for answer as to what it actually meant and found out that when a service is started a logfile is created in the /var/lock/subsys. Sometimes if the service is not stopped properly or whatever the logfile remains created. Though i started/stopped the snmpd service properly it didnt go away so i removed the file manually (via rm cmd). when i checked the status the error "snmpd dead but subsys locked" was gone. On my NMS i recieved the alert of snmpd coldstart. i started the snmpd service everything goes fine! BUT after 5 mins again i recieve the same error message and this keeps on happening..what do i need to do now?

    Read the article

  • Snmpd update interface counters slowly or something like this

    - by Korjavin Ivan
    I update one my freebsd box to 9-stable (totally new installation) and install net-snmp for monitoring. uname -r 9.1-PRERELEASE pkg_info net-snmp-5.7.1_7 Information for net-snmp-5.7.1_7: Comment: An extendable SNMP implementation .... cat /var/db/ports/net-snmp/options # This file is auto-generated by 'make config'. # Options for net-snmp-5.7.1_7 _OPTIONS_READ=net-snmp-5.7.1_7 _FILE_COMPLETE_OPTIONS_LIST= IPV6 MFD_REWRITES PERL PERL_EMBEDDED PYTHON DUMMY TKMIB DMALLOC MYSQL AX_SOCKONLY UNPRIVILEGED OPTIONS_FILE_UNSET+=IPV6 OPTIONS_FILE_UNSET+=MFD_REWRITES OPTIONS_FILE_SET+=PERL OPTIONS_FILE_SET+=PERL_EMBEDDED OPTIONS_FILE_UNSET+=PYTHON OPTIONS_FILE_SET+=DUMMY OPTIONS_FILE_UNSET+=TKMIB OPTIONS_FILE_SET+=DMALLOC OPTIONS_FILE_UNSET+=MYSQL OPTIONS_FILE_UNSET+=AX_SOCKONLY OPTIONS_FILE_UNSET+=UNPRIVILEGED I have about 500 vlan on this machine, and collect info about interface through snmpd to 2 different software, zabbix and cacti. And both of them plot the graphs with blank fields. I tryed change polling time in zabbix, from 15, sec to 30,60,90,120,10. And anyway i have blank fields. snmpd.conf is empty - only a access controls. This configuration worked fine on freebsd 8. Where is my fault? How fix this graphs? UPD: Changing pooling time, switch off one of agent, doesnt help. I look at zabbix log (recieved data from snmpd) and see that: sorry for russian locale, just look at numbers: and thats is not true, as my "iftop" show speed was about 90Mbits, but snmpd return 2Mbits. I understand that snmpd doesnt return speed, it return just a counter. But how its possible? why 2Mbit/s ? I tryed recompile snmpd with 64-bit counters, and without it. In both variants this blank fields present. So i think its my OS (freebsd) doesnt update interface counters well. I still collect tcpdump for found this request/response. But have problem with that, to much trash. UPD2: I decrypt tcpdump-ed file, and public this as google doc at gdocfile Timediff looks strange.. Like zabbix sometimes "forget" do request, and then do twice at row, ehh UPD3: I parse log from command "while true; do netstat -bin -I vlan4008 /var/log/netstat; sleep 300; done" and load as google docs, and add formula for speed : link Looks like all counters in OS are good. Now i think problem in : 1. zabbix get request twice at row (and what about cacti) 2. snmpd use counter32

    Read the article

  • SNMPD timeout yet netcat shows port as open

    - by Kirill Gordeenko
    SNMPD config (I have this config working on a different server): com2sec readonly default public group MyROGroup v1 readonly group MyROGroup v2c readonly group MyROGroup usm readonly view all included .1 80 access MyROGroup "" any noauth exact all none none syslocation <LOCATION> syscontact <CONTACT> When I check the port from remote machine: » nc -zvu xx.xx.xx.xx 161 Connection to xx.xx.xx.xx 161 port [udp/snmp] succeeded! This also works locally (I get all the right stats): snmpwalk -v 2c -c public localhost Yet when I try same command locally or remotely with external IP: Timeout: No Response from xx.xx.xx.xx IPTables are disabled on both machines. /etc/sysconfig/snmpd looks like this: OPTIONS="-Lsd -Lf /dev/null -p /var/run/snmpd.pid" -a /etc/default/snmpd is empty.

    Read the article

  • SNMPD running but not listening for connections at random

    - by Lukasz
    OS: CentOS release 5.7 (Final) Net-SNMP: net-snmp-5.3.2.2-14.el5_7.1 (from RPM) Periodically my NMS notifies me that SNMP has gone down on this machine. The service is restored in between 10 to 30 minutes. My NMS also pings and check SSH and those services are not affected during the SNMP outage. SNMPD log file shows that it is working and apparently receiving packets (either from local agents from 127.0.0.1 or from my NMS at 172.16.37.37) however attempting to snmpwalk locally or from the NMS system fails with a timeout. I have 7 of these servers running mixture of CentOS 5.7 and RHEL 5.7 with this specific version of Net-SNMP installed from RPM - none of them have this issue except this one. 5 of the machines (including the NMS system and this problem server) are in the same rack connected using one switch. Restarting SNMPD does not fix the issue - it clears up by itself eventually. Any suggestions where I can begin diagnosing the issue? It's a closed subnet so IPTables is not used. SNMPD config below: # Following entries were added by HP Insight Management Agents at # Tue May 15 10:58:17 CLT 2012 dlmod cmaX /usr/lib64/libcmaX64.so rwcommunity public 127.0.0.1 rocommunity public 127.0.0.1 rwcommunity 3adRabRu 172.16.37.37 rocommunity 3adRabRu 172.16.37.37 rwcommunity 3adRabRu 172.16.37.36 rocommunity 3adRabRu 172.16.37.36 trapcommunity callmetraps trapsink 172.16.37.37 callmetraps trapsink 172.16.37.36 callmetraps syscontact Lukasz Piwowarek syslocation Santiago, Chile # ---------------------- END -------------------- agentAddress udp:161 com2sec rwlocal default public com2sec rolocal default public com2sec subnet default 3adRabRu group rwv2c v2c rwlocal group rov2c v2c rolocal group rov2c v2c subnet view all included .1 access rwv2c "" any noauth exact all all none access rov2c "" any noauth exact all none none

    Read the article

  • snmpd.conf network range not accepted

    - by Stefan
    I am using snmpd on CentOS 6.3 and was giving a network range to the source for mapping community to security group. com2sec mynetwork 192.168.0.0/23 centreon Anyhow it is not working and I always get a timeout from the polling server. When I enter the exact ip of the polling server it works (192.168.3.180) It even works if I enter the whole netmask (255.255.252.0) Anyhow it should work according to documentation. Did I do anything wrong?

    Read the article

  • Cacti not working for SNMP data sources

    - by lorenzo-s
    I installed packages cacti and snmpd on a Debian server. I'm able to display common graphs in Cacti (such as memory usage, load average, logged in users, etc) using the data templates listed as Unix. Now I want to replace these graphs with new ones using SNMP data sources, because I see there is also CPU usage and because it's not excluded I have to manage multiple hosts in the future. So, I installed snmpd on the machine and left the snmpd.conf as it is. In Cacti, I created three new data sources from SNMP templates for 127.0.0.1 host: ucd/net - CPU Usage - Nice ucd/net - CPU Usage - System ucd/net - CPU Usage - User Then I created a new graph from template ucd/net - CPU Usage, and select the three data sources in the Graph Item Fields section. Graph is now enabled and running, but empty. No data have been collected. Under Console - Devices my SNMP host is listed as up and running: System:Linux ip-xx-xx-xxx-xxx 3.2.0-23-virtual #36-Ubuntu SMP Tue Apr 10 22:29:03 UTC 2012 x86_64 Uptime: 929267 (0 days, 2 hours, 34 minutes) Hostname: ip-xx-xx-xxx-xxx Location: Sitting on the Dock of the Bay Contact: Me [email protected] In SNMP Options I left all as it is: SNMP Version: Version 1 SNMP Community: public SNMP Timeout: 500 ms Maximum OID's Per Get Request: 10 In Console - Utilities - Cacti Log I have multiple warning (two for each data source) every 5 minutes: 10/29/2012 01:45:01 PM - CMDPHP: Poller[0] Host[2] DS[18] WARNING: Result from SNMP not valid. Partial Result: U 10/29/2012 01:45:01 PM - CMDPHP: Poller[0] WARNING: SNMP Get Timeout for Host:'127.0.0.1', and OID:'.1.3.6.1.4.1.2021.4.15.0' 10/29/2012 01:45:01 PM - CMDPHP: Poller[0] Host[1] DS[9] WARNING: Result from SNMP not valid. Partial Result: U 10/29/2012 01:45:01 PM - CMDPHP: Poller[0] WARNING: SNMP Get Timeout for Host:'127.0.0.1', and OID:'.1.3.6.1.4.1.2021.11.52.0' 10/29/2012 01:40:01 PM - CMDPHP: Poller[0] Host[2] DS[19] WARNING: Result from SNMP not valid. Partial Result: U 10/29/2012 01:40:01 PM - CMDPHP: Poller[0] WARNING: SNMP Get Timeout for Host:'127.0.0.1', and OID:'.1.3.6.1.4.1.2021.4.6.0' [...] I have the feeling I'm missing something, but I cannot get it...

    Read the article

  • SNMPD - passing values in a trap

    - by ethrbunny
    Im trying to create an SNMP setup to monitor 500-1K machines. Each will be joined to the SNMPTRAPD server via a VPN. When the client system sends its messages, it's sending its internal address instead of the VPN address even though the 'trapsync' command is using the VPN. This will be a problem as many of these system will have DHCP addresses based on location so there will be overlap. What I'd like to figure out is how to pass extra values with the trap so I can identify which system a given trap comes from.

    Read the article

  • Snmp configuration giving me timeout, no response

    - by imaginative
    This is definitely not a firewall issue as no firewalls are in between the src and tgt machines. I'm simply setting up snmp to be queried by a nagios server. My snmpd.conf looks like the following (I'm using net-snmp on Ubuntu 9.10): com2sec nagiossrv 10.10.10.10 public group Nagios v1 nagiossrv view all included .1 access Nagios any noauth exact all none none When I try to walk it: t:/etc/nagios3# snmpwalk -v1 -c public 10.10.10.10 system Timeout: No Response from 10.10.10.10 Any idea where I went wrong with my configuration?

    Read the article

  • snmp trap using disman-event mib related issue

    - by jatin bodarya
    notificationEvent ifMtu.1 IF-MIB::ifMtu.1 1.3.6.1.2.1.2.2.1.4.1 monitor -I -u root -s -t -r 18 "Warn: High ipp Usage" -e ifMtu.1 1.3.6.1.2.1.2.2.1.4.1 != The above lines are in my snmpd.conf file which is generating a trap when the condition evaluates to false. My issue is that I want to send "Trap Severity Levels" with it. Is it possible? If so, how? If it isn't is there any other way to send them?

    Read the article

  • Finding out why Dell Controler is Degraded

    - by Kyle Brandt
    I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState: [root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up. A walk of the entire storage management tree for on of them: StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

    Read the article

  • SNMP bytes received disagrees with ifconfig

    - by NightFalcon
    SNMP ifInOctets = 2145342796 - about 2GB. ifconfig: RX bytes:174302710687 (174.3 GB) Interestingly, the sent bytes agree almost perfectly: ifOutOctets: 1002415050 - about 1GB ifconfig: TX bytes:1002418728 (1.0 GB) It's not an SNMP discontinuity: snmpwalk -v2c -c public localhost 1.3.6.1.2.1.31.1.1.1.19 iso.3.6.1.2.1.31.1.1.1.19.1 = Timeticks: (0) 0:00:00.00 iso.3.6.1.2.1.31.1.1.1.19.2 = Timeticks: (0) 0:00:00.00 iso.3.6.1.2.1.31.1.1.1.19.3 = Timeticks: (0) 0:00:00.00 Anyone have an idea for this discontinuity in the sent data numbers? Thanks so much! (net-snmp, Ubuntu Linux, 12.04 LTS)

    Read the article

  • Force snmptrapd to log only v2c traps

    - by dare2be
    Hello, I am in the middle of writing new network management software for my University. However, I need to implement a quickie solution to handle specific traps. Right now, my snmptrapd is configured to accept any traps, i.e.: # /etc/snmp/snmptrapd.conf authCommunity log publicString logOption f /var/log/snmptrapd.log format1 "" format2 "%02.2h:%02.2j %b %N\n" What I basically want to do is to log ONLY v2c traps. I intended to do it with setting the format for v1 traps to null (format 1 "") but snmptrapd keeps sending "" to its log. Does anybody know a workaround for this?

    Read the article

  • Cacti dskIndex RHEL

    - by andyh_ky
    I'm attempting to use includeAllDisks in my snmpd.conf for RHEL 4 and RHEL 5 machines, but no data is being returned on the Cacti Data Query. snmpwalk isn't giving me any results. $ snmpwalk -v 2c -c public 172.19.4.140 .1.3.6.1.4.1.2021.9.1.1 UCD-SNMP-MIB::dskIndex = No Such Instance currently exists at this OID If I add disk / to snmpd.conf snmpwalk gives me the right results. $ snmpwalk -v 2c -c public 172.19.4.140 .1.3.6.1.4.1.2021.9.1.1 UCD-SNMP-MIB::dskIndex.1 = INTEGER: 1 I am wanting to deploy this to many systems using the same snmpd.conf (via Satellite). The disk configuration varies among systems and manually configuring snmpd.conf is not an optimal solution. Is there a way to get includeAllDisks to work? My snmpd.conf file: rocommunity public <cacti server IP> dontPrintUnits true includeAllDisks

    Read the article

  • SNMP closed state in CentOS

    - by anksoWX
    I'm having a problem here, I've added to my IPtables rules this: -A INPUT -p tcp -m state --state NEW -m tcp --dport 161 -j ACCEPT -A INPUT -p udp -m state --state NEW -m udp --dport 161 -j ACCEPT but when I scan with nmap or any other tool it says this: Not shown: 998 filtered ports PORT STATE SERVICE 22/tcp open ssh 161/tcp closed snmp also when I am doing: netstat -apn | grep snmpd tcp 0 0 127.0.0.1:199 0.0.0.0:* LISTEN 3669/snmpd<br> udp 0 0 0.0.0.0:161 0.0.0.0:* 3669/snmpd<br> unix 2 [ ] DGRAM 226186 3669/snmpd Also: service iptables status Table: filter Chain INPUT (policy ACCEPT) num target prot opt source destination 1 ACCEPT all -- 0.0.0.0/0 0.0.0.0/0 state RELATED,ESTABLISHED 2 ACCEPT icmp -- 0.0.0.0/0 0.0.0.0/0 3 ACCEPT all -- 0.0.0.0/0 0.0.0.0/0 4 ACCEPT tcp -- 0.0.0.0/0 0.0.0.0/0 state NEW tcp dpt:161 5 ACCEPT udp -- 0.0.0.0/0 0.0.0.0/0 state NEW udp dpt:161 6 ACCEPT tcp -- 0.0.0.0/0 0.0.0.0/0 state NEW tcp dpt:22 7 REJECT all -- 0.0.0.0/0 0.0.0.0/0 reject-with icmp-host-prohibited Chain FORWARD (policy ACCEPT) num target prot opt source destination 1 REJECT all -- 0.0.0.0/0 0.0.0.0/0 reject-with icmp-host-prohibited Chain OUTPUT (policy ACCEPT) num target prot opt source destination Any idea what's going on? There is no UDP in closed/open state. what do I have to do?

    Read the article

  • Filtering SNMP View

    - by Arie K
    We have several network interfaces in a machine. How to configure SNMP view to limit which interfaces could be shown to public community? We're using Ubuntu Server and default SNMPD from the repository. We have successfully limit the SNMPD agent to show only interfaces tree using this configuration: view system included .iso.org.dod.internet.mgmt.mib-2.interfaces

    Read the article

  • SNMP Access on Ubuntu

    - by javano
    I am trying to use SNMP to monitor a machine locally on its self and remotely. This is the snmpd.conf (Ubuntu 8.04.1): # sec.name source comunity com2sec readonly 1.2.3.4 nicenandtight com2sec readonly 5.6.7.8 reallysafe group MyROGroup v1 readonly group MyROGroup v2c readonly group MyROGroup usm readonly view all included .1 view system included .iso.org.dod.internet.mgmt.mib-2.system access MyROGroup "" any noauth exact all none none syslocation my house syscontact me <[email protected]> exec .1.3.6.1.4.1.2021.7890.1 distro /usr/bin/distro smuxpeer .1.3.6.1.4.1.674.10892.1 includeAllDisks 95% 1.2.3.4 is the local machines IP and everything is working locally. 5.6.7.8 is the remote machine and initially I am just trying to touch SNMPD with snmpwalk from the remote machine; snmpwalk -v 2c -c reallysafe 1.2.3.4 Timeout: No Response from 1.2.3.4 I have added to iptables as the very first rule; -A INPUT -p udp -m udp --dport 161 -j ACCEPT With such a loose iptables rule I can't see why I can't even touch the SNMPD on that Uubuntu Machine. There are more specific rules further down the table but as I couldn't connect I added the above. TCPDump shows the UDP packets coming in. What could be going wrong here?

    Read the article

  • Ubuntu 12.04 x64 LTS VPN Server not changing IP

    - by user288778
    I used this guide http://silverlinux.blogspot.co.uk/2012/05/how-to-pptp-vpn-on-ubuntu-1204-pptpd.html and it worked fine. I'm able to connect but the problem is, that my IP being changed to "localip" not "remote ip". This is what I get from tail -f /var/log/syslog [code] June 6 00:09:19 instant5860 NetworkManager[1456]: Unmanaged Device found; state CONNECTED forced (see http://bugs.launchpad.net/bugs/191889) June 6 00:09:19 instant5860 NetworkManager[1456]: Marking connection 'Wired connection 1' invalid. June 6 00:09:19 instant5860 NetworkManager[1456]: Activation (eth1) failed. June 6 00:09:19 instant5860 NetworkManager[1456]: Activation (eth1) Stage 4 of 5 (IPv4 Configure Timeout) complete. June 6 00:09:19 instant5860 NetworkManager[1456]: (eth1): device state change: failed - disconnected (reason 'none') [120 30 0] June 6 00:09:19 instant5860 NetworkManager[1456]: (eth1): deactivating device (reason 'none') [0] June 6 00:09:19 instant5860 NetworkManager[1456]: Unmanaged Device found; state CONNECTED forced. June----- avahi-daemon[440]: Withdrawing address record for fe80......... on eth1 Jun------avahi-daemon[440]: Leaving mDNS multicast group on interface eth1. IPv6 with address fe80..... Jun------avahi-daemon[440]: Interface eth1.IPv6 no longer relevant for mDNS. Jun------avahi-daemon[440]: Joining mDNS multicast group on interface eth1.IPv6 with address fe80.... Jun------avahi-daemon[440]: New relevant interface eth1.IPv6 for mDNS Jun------avahi-daemon[440]: Registering new address record for fe80..... on eth1.*. Jun - snmpd[1172]: error on subcontainer 'ia_addr' insert (-1) dbusp382]: [syste] Activating service name='org.freedesktop.PackageKit' (using servicehelper) AptDaemon: INFO: Initializing daemon AptDaemon.PackageKit: INFO: Initializing PackageKit compat layer dbus[382]: [system] Successfu;;y activated service 'org.freedesktop.PackageKit' AptDaemon.PackageKit: INFO: Initializing PackageKit transaction AptDaemon.Worker: INFO: Simulating trans: /org/debian/apt/transaction/233beca013a0473ea34d9dea805af5df AptDaemon.Worker: INFO: Processing transaction /org/debian/apt... AptDaemon.PackageKit: INFO: Get updates() AptDaemon.Worker: INFO: Finished snmpd[1172]: error on subcontainer pptpd[23611]: CTRL: Client 82.33.... control connection started pptpd[23611]: CTRL: Starting call (launching pppd, opening GRE) pptpd[23611]: pppd 2.4.5 started by root uid 0 pptpd[23611]: Using interface ppp0 pptpd[23611]: Connect ppp0 <-- /dev/pts/1 NetworkManager[1456]: SCPlugin - Ifupdown: device added (path: /sys/devices/virtual/net/ppp0, iface: ppp0) NetworkManager[1456]:SCPlugin - Ifupdown: device added (path: /sys/devices/virtual/net/ppp0, iface: ppp0): no ifupdown configuration found. pptpd[23612]: peer from calling number 82... authorized. kernel: [2918261.416923] init: ufw pre-start process (23613) terminated with status 1 dhclient: DHCPDISCOVER on eth1 to 255.255.255.255 port 67 interval 7 CTRL: Ignored a SET LING info packet with real ACCMs! local IP address:109.0.121.197 remote IP address: 109.0.84.56 dhclient: DHCPDISCOVER on eth1 to 255.255.255.255 port 67 interval 13 NetworkManager[1456]: (eth1): DHCPv4 request timed out. NetworkManager[1456]: (eth1): canceled DHCP transaction, DHCP client pid 23280 NetworkManager[1456]: Activation (eth1) Stage 4 of 5 (IPv4 Configure Timeout) scheduled... NetworkManager[1456]: Activation (eth1) Stage 4 of 5 (IPv4 Configure Timeout) started... NetworkManager[1456]: (eth1): device state change: ip-config - failed (reason 'ip-config-unavailable') [70 120 5[ NetworkManager[1456]: Unmanaged 'ia_addr' insert (-1)[/code]

    Read the article

  • Make Dell's OpenManage 6.2 information available through SNMP

    - by tronda
    I have successfully installed OpenManage on a CentOS 5.4 server and I'm able to use OpenManage through the web interface running on port 1311, but I would like to be able to expose this information through the SNMP server. I don't know SNMP particularly well so the configuration is a result of trial and error. I've tried to follow the description pointed out in the Open Manage Server Administrator User Guide. I've followed the documentation regarding SNMP configuration, but without success. I've created a small snmpd.conf file: com2sec notConfigUser default public group notConfigGroup v1 notConfigUser group notConfigGroup v2c notConfigUser view systemview included .1.3.6.1.2.1.1 view systemview included .1.3.6.1.2.1.25.1.1 access notConfigGroup "" any noauth exact all all none view all included .1 rwcommunity public 10.200.26.50 syslocation "Somewhere" syscontact [email protected] pass .1.3.6.1.4.1.4413.4.1 /usr/bin/ucd5820stat smuxpeer .1.3.6.1.4.1.674.10892.1 When I try to fetch SNMP information by using snmpwalk I get the following output: SNMPv2-MIB::sysDescr.0 = STRING: Linux myserver.test.com 2.6.18-164.15.1.el5 #1 SMP Wed Mar 17 11:30:06 EDT 2010 x86_64 SNMPv2-MIB::sysObjectID.0 = OID: NET-SNMP-MIB::netSnmpAgentOIDs.10 DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (1180389) 3:16:43.89 SNMPv2-MIB::sysContact.0 = STRING: [email protected] SNMPv2-MIB::sysName.0 = STRING: myserver.test.com SNMPv2-MIB::sysLocation.0 = STRING: "Somewhere" SNMPv2-MIB::sysORLastChange.0 = Timeticks: (0) 0:00:00.00 SNMPv2-MIB::sysORID.1 = OID: SNMPv2-MIB::snmpMIB SNMPv2-MIB::sysORID.2 = OID: TCP-MIB::tcpMIB SNMPv2-MIB::sysORID.3 = OID: IP-MIB::ip SNMPv2-MIB::sysORID.4 = OID: UDP-MIB::udpMIB SNMPv2-MIB::sysORID.5 = OID: SNMP-VIEW-BASED-ACM-MIB::vacmBasicGroup SNMPv2-MIB::sysORID.6 = OID: SNMP-FRAMEWORK-MIB::snmpFrameworkMIBCompliance SNMPv2-MIB::sysORID.7 = OID: SNMP-MPD-MIB::snmpMPDCompliance SNMPv2-MIB::sysORID.8 = OID: SNMP-USER-BASED-SM-MIB::usmMIBCompliance SNMPv2-MIB::sysORDescr.1 = STRING: The MIB module for SNMPv2 entities SNMPv2-MIB::sysORDescr.2 = STRING: The MIB module for managing TCP implementations SNMPv2-MIB::sysORDescr.3 = STRING: The MIB module for managing IP and ICMP implementations SNMPv2-MIB::sysORDescr.4 = STRING: The MIB module for managing UDP implementations SNMPv2-MIB::sysORDescr.5 = STRING: View-based Access Control Model for SNMP. SNMPv2-MIB::sysORDescr.6 = STRING: The SNMP Management Architecture MIB. SNMPv2-MIB::sysORDescr.7 = STRING: The MIB for Message Processing and Dispatching. SNMPv2-MIB::sysORDescr.8 = STRING: The management information definitions for the SNMP User-based Security Model. SNMPv2-MIB::sysORUpTime.1 = Timeticks: (0) 0:00:00.00 SNMPv2-MIB::sysORUpTime.2 = Timeticks: (0) 0:00:00.00 SNMPv2-MIB::sysORUpTime.3 = Timeticks: (0) 0:00:00.00 SNMPv2-MIB::sysORUpTime.4 = Timeticks: (0) 0:00:00.00 SNMPv2-MIB::sysORUpTime.5 = Timeticks: (0) 0:00:00.00 SNMPv2-MIB::sysORUpTime.6 = Timeticks: (0) 0:00:00.00 SNMPv2-MIB::sysORUpTime.7 = Timeticks: (0) 0:00:00.00 SNMPv2-MIB::sysORUpTime.8 = Timeticks: (0) 0:00:00.00 I suspect that I should get some DELL specific information when I use the snmpwalk utility. Is there a configuration in snmpd.conf file which is wrong, or do I have to configure on the OpenManage side in order to get the hardware information accessible from SNMP?

    Read the article

  • SNMP custom script :: OID not increasing

    - by amprantino
    I try to create a custom SNMP oid. I add the following like to snmpd.conf (and restart service) : pass .1.3.6.1.3.2 /bin/myscript.sh cat myscript.sh #!/bin/sh echo .1.3.6.1.3.2 echo gauge exec 100 snmpwalk -c mycommunity -v2c 10.2.1.4 .1.3.6.1.3.2 SNMPv2-SMI::experimental.2 = Gauge32: 100 Error: OID not increasing: SNMPv2-SMI::experimental.2 >= SNMPv2-SMI::experimental.2 Is snmpwalk expecting anything at the end of the query ? snmpget work with no problem! Thank you

    Read the article

  • Apache+PHP problem: Cannot list processes other than apache's

    - by Satanowski
    I have a quite fresh install of the Apache (2.2.3/Centos) + PHP(5.1.6) and following problem: I need to monitor life of one process and in order to do that I run: $last_line = exec('ps -C snmpd'); and check its output. Unfortunately I always get nothing. I've checked it with other process names and it seems it can 'see' only Apache's processes. Any idea how to work this out?

    Read the article

  • Other processes take over port 80 when restarting Apache - why, and how to solve?

    - by user72149
    I have a CentOS 5.5 server running Apache on port 80 as well as some other applications. All works fine until I for some reason need to restart the httpd process. Doing so returns: sudo /etc/init.d/httpd restart Stopping httpd: [ OK ] Starting httpd: (98)Address already in use: make_sock: could not bind to address [::]:80 (98)Address already in use: make_sock: could not bind to address 0.0.0.0:80 no listening sockets available, shutting down Unable to open logs First I thought perhaps httpd had frozen and was still running, but that was not the case. So I ran netstat to find out what was using port 80: sudo netstat -tlp Active Internet connections (only servers) Proto Recv-Q Send-Q Local Address Foreign Address State PID/Program name tcp 0 0 *:7203 *:* LISTEN 24012/java tcp 0 0 localhost.localdomain:smux *:* LISTEN 3547/snmpd tcp 0 0 *:mysql *:* LISTEN 21966/mysqld tcp 0 0 *:ssh *:* LISTEN 3562/sshd tcp 0 0 *:http *:* LISTEN 3780/python26 Turns out that my python process had taken over listening to http in the instant that httpd was restarting. So, I killed python and tried starting httpd again - but ran into the same error. Netstat again: sudo netstat -tlp Active Internet connections (only servers) Proto Recv-Q Send-Q Local Address Foreign Address State PID/Program name tcp 0 0 *:7203 *:* LISTEN 24012/java tcp 0 0 localhost.localdomain:smux *:* LISTEN 3547/snmpd tcp 0 0 *:mysql *:* LISTEN 21966/mysqld tcp 0 0 *:ssh *:* LISTEN 3562/sshd tcp 0 0 *:http *:* LISTEN 24012/java Now my java process had taken over listening to http. I killed that too and could then successfully restart httpd. But this is a terrible workaround. Why will these python and java processes start listening to port 80 as soon as httpd is restarted? How to solve? Two other comments. 1) Both java and python processes are started by apache from a php script. But when apache is restarted, they should not be affected. And 2) I have the same setup on two other machines running Ubuntu and there's no problem there. Any ideas? Edit: The Java process listens to port 7203 and the python process supposedly doesn't listen to any port. For some reason, they start listening to port 80 when apache is restarted. This hasn't happened before. On Ubuntu it runs fine. For some reason, on my current CentOS 5.5 machine, this problem arises.

    Read the article

  • free -m output, should I be concerend about this servers low memory?

    - by Michael
    This is the output of free -m on a production database (MySQL with machine. 83MB looks pretty bad, but I assume the buffer/cache will be used instead of Swap? [admin@db1 www]$ free -m total used free shared buffers cached Mem: 16053 15970 83 0 122 5343 -/+ buffers/cache: 10504 5549 Swap: 2047 0 2047 top ouptut sorted by memory: top - 10:51:35 up 140 days, 7:58, 1 user, load average: 2.01, 1.47, 1.23 Tasks: 129 total, 1 running, 128 sleeping, 0 stopped, 0 zombie Cpu(s): 6.5%us, 1.2%sy, 0.0%ni, 60.2%id, 31.5%wa, 0.2%hi, 0.5%si, 0.0%st Mem: 16439060k total, 16353940k used, 85120k free, 122056k buffers Swap: 2096472k total, 104k used, 2096368k free, 5461160k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 20757 mysql 15 0 10.2g 9.7g 5440 S 29.0 61.6 28588:24 mysqld 16610 root 15 0 184m 18m 4340 S 0.0 0.1 0:32.89 sysshepd 9394 root 15 0 154m 8336 4244 S 0.0 0.1 0:12.20 snmpd 17481 ntp 15 0 23416 5044 3916 S 0.0 0.0 0:02.32 ntpd 2000 root 5 -10 12652 4464 3184 S 0.0 0.0 0:00.00 iscsid 8768 root 15 0 90164 3376 2644 S 0.0 0.0 0:00.01 sshd

    Read the article