  • Spinup time failure

    - by bioShark
    I am not sure this is a real question or a bug I should report Ubuntu. Using: Ubuntu 11.10, on a Intel Q6600, Samsung Spinpoint F4 2TB. I have set my PC on Suspend and after I came back, pressed Enter and after logging in everything was back to normal. However, I had a message from Disk Utility that one disk reports errors. I entered Disk Utility, and my Samsung 2TB disk, the one on which my Ubuntu is installed, had the SMART Status turned red, with error message on it. The error was: Spinup time failed Value 21, Threshold value was 25 (so the error was reported because 21 < 25) I restarted and booted up in Windows to see what HD Tune is reporting. Unfortunately it was exactly the same 21/25. After reading up on Wiki about SMART and the errors, I discovered that Spinup time is the time required for the disk to reach full spinning speed in milliseconds. Then it hit me that, in Ubuntu I had Suspended the system, making essentially all my hardware stop. And when I rebooted to Windows, the hardware doesn't really stop, so SMART's reading of the Spinup time was still from Ubuntu's suspension. So I did a full PC stop and then booted up again, both in Ubuntu and Windows to see if there are different readings. Both reported successful Spinup time, 68 (a little better then 21 :) ), although in Disk Utility I have a nice message: Failed in the Past So now I am pretty sure that Ubuntu didn't handle the Suspend correctly, but then again should I worry about Imminent hardware failure ? Am I missing some drivers? Should I report this as a bug to Ubuntu? Sorry if this was a bad place to ask this question.

    Read the article

  • With Ubuntu 9.10, my DVD keeps spinning up

    - by Ken
    I have Ubuntu 9.10 on my Intel Mac Mini. When there's a DVD in the drive, and even if there's no program open at all (just looking at the desktop), every minute or so the disc spins up with a loud whirring noise, and I can hear it cranking the motor to seek across the disc. How do I find out what's causing this? And how can I make it stop? Thanks! EDIT: I straced nautilus, and saw nothing it's doing directly, even when the disc spins up. It does poll inotify regularly, but I don't know how to trace what it's watching, or if that's even how it receives disc-inserted notifications. It doesn't call inotify_add_watch when I insert a disc or mount it (or eject or umount), but it could be watching all of /dev already or something like that. Of course, a DVD is mounted read-only, so whether it's inotify or something else, it should never need to poll anything on that. And if it is inotify, it's happening in the kernel, and the kernel should really never need to poll a device it's mounted to check for notifications.

    Read the article

  • Why does my DVD drive spin up every minute or so, spin down, and repeat (new Dell Studio 15 with Win

    - by cybergibbons
    We have just got a new Dell Studio 15 laptop running Windows 7 home premium with slot load DVD drive. If there is a DVD drive in the drive, every minute or so, the drive will spin up, make a couple of noises like it is reading something and then spin down. I think this is ruining battery life. There is no software running that is obviously accessing the drive. Any ideas to what it could be? Are there any tools I could use to try and identify the problem? Thanks.

    Read the article

  • SSD cache to minimize HDD spin-up time?

    - by sirprize
    short version first: I'm looking for Linux compatible software which is able to transparently cache HDD writes using an SSD. However, I only want to spin up the HDD once or twice a day (to write the cached data to the HDD). The rest of the time, the HDD should not be spinning due to noise concerns. Now the longer version: I have built a completely silent computer running Xubuntu. It has a A10-6700T APU, huge fanless cooler, fanless PSU, SSD. The problem is: it also has (and needs) a noisy HDD and I want to forbid spinning it up during the night. All writes should be cached on the SSD, reads are not needed in the night. Throughout every day, this computer will automatically download about 5 GB of data which will be retained for about a year, giving a total needed disk capacity of slightly less than 2 TB. This data is currently stored on a 3 TB noisy hard disk drive which is spinning day and night. Sometimes, I'll need to access some data from several months ago. However, most times I'll only need data from the last 14 days, which would fit on the SSD. Ideally, I'd like a transparent solution (all data on one filesystem) which caches all writes to the SSD, writing to the HDD only once a day. Reads would be served by the cache if they were still on the SDD, else the HDD would have to spin up. I have tried bcache without much success (using cache_mode=writeback, writeback_running=0, writeback_delay=86400, sequential_cutoff=0, congested_write_threshold_us=0 - anything missing?) and I read about ZFS ZIL/L2ARC but I'm not sure I can achieve my goal with ZFS. Any pointers? If all else fails, I will simply use some scripts to automatically copy files over to the big drive while deleting the oldest files from the SSD.

    Read the article

  • (EXCEL)VBA Spin button which steps through in an sql databases date time

    - by Gulredy
    I have an sql Database table in MySQL which have lots of rows with varied date time values. For example: 2012-08-21 10:10:00 <-- with these date there are around 12 rows 2012-08-21 15:31:00 <-- with these date there are around 5 rows 2012-08-22 11:40:00 <-- with these date there are around 10 rows 2012-08-22 12:17:00 <-- with these date there are around 9 rows 2012-08-22 12:18:00 <-- with these date there are around 7 rows 2012-08-25 07:21:00 <-- with these date there are around 6 rows If the user clicks on the SpinButton1_SpinUp() or SpinButton1_SpinDown() button then it should do the following: The SpinButton1_SpinUp() button should filter out those data from an sql table which is the next after what we are currently on now. Example: We have currently selected: 2012-08-21 15:31:00. The user hits the SpinUp button then the program selects those date from the database, which is the next higher value like this one: 2012-08-22 11:40:00. So the user hits the SpinUp button the data which is selected in the database will change from those with date: 2012-08-21 15:31:00 to those with date: 2012-08-22 11:40:00 The SpinButton1_SpinDown() will do exactly the reverse of the SpinUp button. When the user hits the SpinDown button the data which is selected in the database will change from those with date: 2012-08-21 15:31:00 to those with date 2012-08-21 10:10:00 So I think the date which we are currently on, should be stored in a variable. But on button hit not every bigger or lower data should be selected in the database, only those which are the closest bigger or the closest lower date. How can I do this? I hope I described my problem understandable. My native language is not english, so misunderstandings can occur! Please ask if you don't understand something! Thank you for reading!

    Read the article

  • Adaptec 5805 after reboot don't starting

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not included. It only works if the computer is shut down and turn off. Late i update firmware "Adaptec RAID 5805 Firmware Build 18948" How to fix the problem? add Log Configuration summary Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priorityHigh Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1 List item

    Read the article

  • Adaptec 5805 not recognized after reboot

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not recognized. It only works if the computer is shut down and turned off. I have recently updated the firmware to "Adaptec RAID 5805 Firmware Build 18948". How do I fix the problem? Configuration summary --------------------------- 1. Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priority High Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Disk is spinning down each minute, unable to disable it

    - by lzap
    I played with spindown and APM settings of my Samsung discs and now they spin down every minute. I want to disable it, but it seems it does not accept any of the spindown time or APM values. Nothing works, it's all the same. Please help what values should be proper for it. I do not want it to spin down at all. /dev/sda: ATA device, with non-removable media Model Number: SAMSUNG HD154UI Serial Number: S1Y6J1KZ206527 Firmware Revision: 1AG01118 Standards: Used: ATA-8-ACS revision 3b Supported: 7 6 5 4 Configuration: Logical max current cylinders 16383 16383 heads 16 16 sectors/track 63 63 -- CHS current addressable sectors: 16514064 LBA user addressable sectors: 268435455 LBA48 user addressable sectors: 2930277168 Logical/Physical Sector size: 512 bytes device size with M = 1024*1024: 1430799 MBytes device size with M = 1000*1000: 1500301 MBytes (1500 GB) cache/buffer size = unknown Capabilities: LBA, IORDY(can be disabled) Queue depth: 32 Standby timer values: spec'd by Standard, no device specific minimum R/W multiple sector transfer: Max = 16 Current = 16 Advanced power management level: 60 Recommended acoustic management value: 254, current value: 0 DMA: mdma0 mdma1 mdma2 udma0 udma1 udma2 udma3 udma4 udma5 *udma6 udma7 Cycle time: min=120ns recommended=120ns PIO: pio0 pio1 pio2 pio3 pio4 Cycle time: no flow control=120ns IORDY flow control=120ns Commands/features: Enabled Supported: * SMART feature set Security Mode feature set * Power Management feature set * Write cache * Look-ahead * Host Protected Area feature set * WRITE_BUFFER command * READ_BUFFER command * NOP cmd * DOWNLOAD_MICROCODE * Advanced Power Management feature set Power-Up In Standby feature set * SET_FEATURES required to spinup after power up SET_MAX security extension Automatic Acoustic Management feature set * 48-bit Address feature set * Device Configuration Overlay feature set * Mandatory FLUSH_CACHE * FLUSH_CACHE_EXT * SMART error logging * SMART self-test Media Card Pass-Through * General Purpose Logging feature set * 64-bit World wide name * WRITE_UNCORRECTABLE_EXT command * {READ,WRITE}_DMA_EXT_GPL commands * Segmented DOWNLOAD_MICROCODE * Gen1 signaling speed (1.5Gb/s) * Gen2 signaling speed (3.0Gb/s) * Native Command Queueing (NCQ) * Host-initiated interface power management * Phy event counters * NCQ priority information DMA Setup Auto-Activate optimization Device-initiated interface power management * Software settings preservation * SMART Command Transport (SCT) feature set * SCT Long Sector Access (AC1) * SCT LBA Segment Access (AC2) * SCT Error Recovery Control (AC3) * SCT Features Control (AC4) * SCT Data Tables (AC5) Security: Master password revision code = 65534 supported not enabled not locked frozen not expired: security count supported: enhanced erase 326min for SECURITY ERASE UNIT. 326min for ENHANCED SECURITY ERASE UNIT. Logical Unit WWN Device Identifier: 50024e900300cca3 NAA : 5 IEEE OUI : 0024e9 Unique ID : 00300cca3 Checksum: correct I have the very same disc which I did not "tuned" and it does not spin. But I do not know where to read the settings from. The hdparm only shows this: Advanced power management level: 60 Recommended acoustic management value: 254, current value: 0 Edit: It seems the issue was tuned daemon in RHEL6. It was too aggressive, I turned off disc tuning and it seems they are no longer spinning down.