Search Results

Search found 34 results on 2 pages for 'smartarray'.

Page 1/2 | 1 2  | Next Page >

  • How to perform diagnostics (stress test) on HP Smartarray Controller

    - by pepoluan
    At my office, we have a server that we suspect its RAID controller (HP Smartarray) is failing. A cold boot, however, does not indicate anything. Can anyone recommend me a method to stress-test the controller? Symptoms that makes me suspect a failing controller: Disk access getting slower, queue getting longer Running dmesg on the XenServer console I see many messages similar to this one: end_request: I/O error, dev tda, sector 253655584 (the sector number is never the same) When we move the VM to another physical host, we no longer see the above message Running idle (without any running VM), the dmesg no longer emit the above message A search on Google indicated that the above message is most commonly associated with a failing SmartArray controller. How can I be sure that the SmartArray controller is failing?

    Read the article

  • Migrating RAID6 array from HP SmartArray P600 to LSI MegaRAID SAS 8888ELP

    - by MLu
    My customer has an external RAID6 array (8x 1TB in HP MSA60 enclosure) attached to HP SmartArray P600 controller. They have now decided to replace the server and the new one comes with LSI MegaRAID SAS 8888ELP. The HW supplier insists the migration is as simple as pulling the eSATA cable from P600 and inserting it into LSI but I'm not convinced. Unfortunately I have nowhere to test, and will have to do the exercise on the production array :( So the question in brief - is it possible to import the HP SmartArray P600-created RAID6 array to LSI MegaRAID 8888ELP?

    Read the article

  • HP SmartArray P212 with non HP disks, Insight Diagnostics error

    - by yonatan
    I have an ML110 G6 with a SmartArray P212 and two Seagate (non-HP) SAS disks in Raid 1. When I ran HP Insight Diagnostics I got some errors related to S.M.A.R.T. error testing and I would like to confirm that this is due to the controller not being able to query the drives as they are non-HP. I believe that the drives are not failing, but I want to be sure. Please have a look at these screenshots I took from the Insight Diagnostics report:

    Read the article

  • HP SmartArray P400 has slow read and write speed

    - by Tadas D.
    I have desktop in which I installed HP SmartArray P400 controller with two HP DF0146B8052 hard drives. I made RAID0 logical volume from them, but I am getting 20MB/s write speed and ~140-120MB/s read speed. Also there is quite low scatter for benchmark results (I am getting quite nice line) and it looks like controller is "capping" my speeds. I tried reseting controllers configuration and I haven't found any settings in HP ACU (Array Configuration Utility) to help me. I am using Windows 7 Ultimate and M4A78 board Does anyone have ideas what could be wrong? Also I am attaching diagnostic results.

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Hi! Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • Extend RAID 1 (HP SmartArray P410i) running Linux

    - by Oliver
    I took over a fairly simple server setup with the following RAID 1 config running Ubuntu 11.10 (Kernel 3.0.0-12-server x86_64): => ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: removed) array A (SAS, Unused Space: 1335535 MB) logicaldrive 1 (279.4 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 1 TB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 1 TB, OK) Initially there were two 300GB disks that got replaced by 1TB disks and I now have to extend the logical volume to use that extra space. However, when trying to do so I get the following warning: => ctrl slot=0 ld 1 modify size=max Warning: Extension may not be supported on certain operating systems. Performing extension on these operating systems can cause data to become inaccessible. See ACU documentation for details. Continue? (y/n) Is it safe to say yes or am I at risk of corrupting the file system / loosing data? Rearranging and extending the file system afterwards shouldn't be an issue as I can take the server offline and boot from a gparted live disk. Here's the config of the RAID controller in use: => ctrl all show detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: removed RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: Rev C Firmware Version: 5.12 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: False Drive Write Cache: Disabled SATA NCQ Supported: True And the partition table: Number Start End Size Type File system Flags 1 1049kB 274GB 274GB primary ext4 boot 2 274GB 300GB 25.8GB extended 5 274GB 300GB 25.8GB logical linux-swap(v1)

    Read the article

  • RAID5 on SmartArray P410i online resize

    - by datacompboy
    I have P410i+256M Cache without battery backup. My RAID5 was build over 3*136GB disks, now all disks were replaced to a 3*300GB array. How can I extend it to use the whole space? HPacucli doesn't allows that, I think this might be because no battery is present. I have a redundant power supply. All data is mirrored over DRBD to a secondary server, so I can try to resize with a chance of loss of data in case of power failure, but I prefer to have an online resize.

    Read the article

  • HP SmartArray P400: How to repair failed logical drive?

    - by TegtmeierDE
    I have a HP Server with SmartArray P400 controller (incl. 256 MB Cache/Battery Backup) with a logicaldrive with replaced failed physicaldrive that does not rebuild. This is how it looked when I detected the error: ~# /usr/sbin/hpacucli ctrl slot=0 show config Smart Array P400 in Slot 0 (Embedded) (sn: XXXX) array A (SATA, Unused Space: 0 MB) logicaldrive 1 (698.6 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 750 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 750 GB, OK) array B (SATA, Unused Space: 0 MB) logicaldrive 2 (2.7 TB, RAID 5, Failed) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 750 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 750 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 750 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 750 GB, Failed) physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 750 GB, OK) unassigned physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SATA, 750 GB, OK) ~# I thought that I had drive 2I:1:8 configured as a spare for Array A and Array B, but it seems this was not the case :-(. I noticed the problem due to I/O errors on the host, even if only 1 physicaldrive of the RAID5 is failed. Does someone know why this could happen? The logicaldrive should go into "Degraded" mode but still be fully accessible from the host os!? I first tried to add the unassigned drive 2I:1:8 as a spare to logicaldrive 2, but this was not possible: ~# /usr/sbin/hpacucli ctrl slot=0 array B add spares=2I:1:8 Error: This operation is not supported with the current configuration. Use the "show" command on devices to show additional details about the configuration. ~# Interestingly it is possible to add the unassigned drive to the first array without problems. I thought maybe the controller put the array into "failed" state due to the missing spare and protects failed arrays from modification. So I tried was to reenable the logicaldrive (to add the spare afterwards): ~# /usr/sbin/hpacucli ctrl slot=0 ld 2 modify reenable Warning: Any previously existing data on the logical drive may not be valid or recoverable. Continue? (y/n) y Error: This operation is not supported with the current configuration. Use the "show" command on devices to show additional details about the configuration. ~# But as you can see, re-enabling the logicaldrive this was not possible. Now I replaced the failed drive by hotswapping it with the unassigned drive. The status now looks like this: ~# /usr/sbin/hpacucli ctrl slot=0 show config Smart Array P400 in Slot 0 (Embedded) (sn: XXXX) array A (SATA, Unused Space: 0 MB) logicaldrive 1 (698.6 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 750 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 750 GB, OK) array B (SATA, Unused Space: 0 MB) logicaldrive 2 (2.7 TB, RAID 5, Failed) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 750 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 750 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 750 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 750 GB, OK) physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 750 GB, OK) ~# The logical drive is still not accessible. Why is it not rebuilding? What can I do? FYI, this is the configuration of my controller: ~# /usr/sbin/hpacucli ctrl slot=0 show Smart Array P400 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: XXXX Cache Serial Number: XXXX RAID 6 (ADG) Status: Enabled Controller Status: OK Chassis Slot: Hardware Revision: Rev E Firmware Version: 5.22 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Analysis Inconsistency Notification: Disabled Raid1 Write Buffering: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 256 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True ~# Thanks for you help in advance.

    Read the article

  • Install server 2012 on HP ML110 G7 with B110i controller, no disks found

    - by Molotch
    I'm trying to install Server 2012 on a HP ML110 G7 with a B110i controller and four non hot-swappable SATA drives. I just can't get the Server 2012 boot disk PE environment to find any disks. I have downloaded the latest SPP (Service Pack for Proliant 2012.10) and flashed the BIOS. I have tried two different HP drivers for B110i and Windows X64, 6.18.0.64 and 6.18.2.64 to no avail. I have tried setting the controller to both AHCI and legacy mode in the BIOS, no difference. HP:s SmartStart disc for G7 servers only support installation of up to Windows Server 2008R2. HP:s installation instructions for Server 2012 Essentials says boot from the windows disk and use the storage drivers found on the SPP (I can't find any storage drivers on the SPP disk).

    Read the article

  • HP P212 hangs on Initializing

    - by user927586
    I'm in trouble... Server: HP Microserver N36L Storage: HP P212/256 with BBWC Drives: 4 WD 2 Tb While expanding the RAID 5 array from 3 to 4 drives, the server rebooted itself. Expansion was at 76%. Now at boot the P212 seems to hang on initializing. After some time screen resets and the server boots, but in the os (Windows Server 2008R2) the P212 has errors (error code 10) and it's not seen by the HP ACU. Whats' going on? It's trying to complete the expansion? It's trying to make all over the expansion? It's simply stuck? What should I do? I NEED the data on the array! PS In the server BIOS, on the hd boot priority, the server still reports the array logical drive... maybe it's a good sign... PPS I'm not at the server physical location, so I cannot tell if the drives in the array are being accessed (that would be the case if the controller it's redoing/completing the expansion process) or not right now. Bye Dario

    Read the article

  • Smart Array P400 - Accelerator Replacement Battery Failure

    - by inflammable
    TL;DR - Is the immediate failure of a replacement battery, for a failed battery, on a battery backed accelerator for a Smart Array P400 controller a common occurrence? Or are we likely to have an storage controller with an impending and critical fault? We have a slightly confusing situation with a Smart Array P400 storage controller with the 512mb battery backed accelerator addon on an HP DL380 server. The storage controller is (afaik) running the latest firmware and driver: Model: Smart Array P400 Controller Status: OK Firmware Version: 7.24 Serial Number: *snip* Rebuild Priority: Medium Expand Priority: Medium Number Of Ports: 2 The storage diagnostic (both on the both boot-up screen for the controller and within the 'Management Homepage' and the 'HP Array Diagnostic Utility') recently starting showing the following status a fault for the battery for the accelerator: Accelerator Status: Temporarily Disabled Error Code: Cache Disabled Low Batteries Serial Number: *snip* Total Memory: 524288 KB Read Cache: 25% Write Cache: 75% Battery Status: Failed Read Errors: 0 Write Errors: 0 We replaced the battery with a new unit (a visual inspection of the P400 card showing nothing unusual) and saw the same fault - but expected this to disappear over the course of a few hours/days as it charged. This didn't happy, and the fault status remains the same as above. Given the battery is a genuine part from HP, I wouldn't have expected a replacement battery to fail straight away, or to be dead-on-arrival (is that naivety on my part?). Is the immediate failure of a replacement battery, for a failed battery, on a battery backed accelerator a common occurrence? Or are we likely to have an storage controller with an impending and critical fault? Is there any diagnostic that could tell me more about the failed battery, without cracking the server open again? Many thanks!

    Read the article

  • hp smart array lock up code 0x15, what is that? (or where can I get a list of descriptions of HP smart array controller lock up codes)

    - by user47650
    Hi, I've had a couple of Dl180 6g boxes hung over the last week, each have a P410 smart array controller. upon reboot the server has indicated that a controller failure event occurred and the previous lock up code was 0x15 - the server rebooted without issue. However there was nothing in the IML log, but the ADU report provided the following; Trap Address High Or Post Results Lockup Reason Or Post Error RIS Updates Or Post Error Detail Firmware Version Trap Address Low 0x8087 0x0015 0x0000033e 0x015e 0xd65c any suggestions on what that code is, my google fu failed. And hp support have not responded with any detail as yet.

    Read the article

  • Is it possible to shrink the size of an HP Smart Array logical drive?

    - by ewwhite
    I know extension is quite possible using the hpacucli utility, but is there an easy way to reduce the size of an existing logical drive (not array)? The controller is a P410i in a ProLiant DL360 G6 server. I'd like to reduce logicaldrive 1 from 72GB to 40GB. => ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438006FD9A50 Cache Serial Number: PAAVP9VYFB8Y RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 3.66 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 512 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 412476 MB Status: OK Logical Drive: 1 Size: 72.0 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 18504 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001C132E4BBDFAA6DAD13DA3 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 196 MB, / 12.0 GB, /usr 8.0 GB, /var 4.0 GB, /tmp 2.0 GB OS Status: LOCKED Logical Drive Label: AE438D6A5001438006FD9A50BE0A Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 Device Number: 250 Firmware Version: RevC WWID: 5001438006FD9A5F Vendor ID: PMCSIERA Model: SRC 8x6G

    Read the article

  • Can't Remove Logical Drive/Array from HP P400

    - by Myles
    This is my first post here. Thank you in advance for any assistance with this matter. I'm trying to remove a logical drive (logical drive 2) and an array (array "B") from my Smart Array P400. The host is a DL580 G5 running 64-bit Red Hat Enterprise Linux Server release 5.7 (Tikanga). I am unable to remove the array using either hpacucli or cpqacuxe. I believe it is because of "OS Status: LOCKED". The file system that lives on this array has been unmounted. I do not want to reboot the host. Is there some way to "release" this logical drive so I can remove the array? Note that I do not need to preserve the data on logical drive 2. I intend to physically remove the drives from the machine and replace them with larger drives. I'm using the cciss kernel module that ships with Red Hat 5.7. Here is some information pertaining to the host and the P400 configuration: [root@gort ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.7 (Tikanga) [root@gort ~]# uname -a Linux gort 2.6.18-274.el5 #1 SMP Fri Jul 8 17:36:59 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux [root@gort ~]# rpm -qa | egrep '^(hp|cpq)' cpqacuxe-9.30-15.0 hp-health-9.25-1551.7.rhel5 hpsmh-7.1.2-3 hpdiags-9.3.0-466 hponcfg-3.1.0-0 hp-snmp-agents-9.25-2384.8.rhel5 hpacucli-9.30-15.0 [root@gort ~]# hpacucli HP Array Configuration Utility CLI 9.30.15.0 Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console. => ctrl all show config detail Smart Array P400 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Cache Serial Number: PA82C0J9SVW34U RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware Revision: D Firmware Version: 7.22 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 128 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Unique Identifier: 600508B100184A395356573334550002 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 101 MB, /tmp 7.8 GB, /usr 3.9 GB, /usr/local 2.0 GB, /var 3.9 GB, / 2.0 GB, /local 113.2 GB OS Status: LOCKED Logical Drive Label: A0027AA78DEE Mirror Group 0: physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) Drive Type: Data Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM57RF40000983878FX Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 35 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM55VQC000098388524 Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 36 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Logical Drive: 2 Size: 546.8 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 256 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Completed Unique Identifier: 600508B100184A395356573334550003 Disk Name: /dev/cciss/c0d1 Mount Points: None OS Status: LOCKED Logical Drive Label: A5C9C6F81504 Drive Type: Data Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2H5PE00009802NK19 Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 37 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 1I:1:4 Port: 1I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM28YY400009750MKPJ Model: HP DG146ABAB4 Current Temperature (C): 31 Maximum Temperature (C): 36 PHY Count: 1 PHY Transfer Rate: 3.0Gbps physicaldrive 2I:1:5 Port: 2I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FGYV00009802N3GN Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 38 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 2I:1:6 Port: 2I Box: 1 Bay: 6 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM8AFAK00009920MMV1 Model: HP DG146BB976 Current Temperature (C): 31 Maximum Temperature (C): 41 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:7 Port: 2I Box: 1 Bay: 7 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FJQD00009801MSHQ Model: HP DG146ABAB4 Current Temperature (C): 29 Maximum Temperature (C): 39 PHY Count: 1 PHY Transfer Rate: Unknown

    Read the article

  • Solaris: detect hotswap SATA disk insert

    - by growse
    What's the method used on Solaris to get the system to rescan for new disks that have been hot-plugged on a SATA controller? I've got an HP X1600 NAS which had 9 drives configred in a ZFS pool. I've added 3 disks, but the format command still only shows the original 9. When I plugged them in, I saw this: cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=12 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO cpqary3: [ID 100000 kern.notice] cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=11 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO cpqary3: [ID 100000 kern.notice] cpqary3: [ID 823470 kern.notice] NOTICE: Smart Array P212 Controller cpqary3: [ID 823470 kern.notice] Hot-plug drive inserted, Port=1I Box=1 Bay=10 cpqary3: [ID 479030 kern.notice] Configured Drive ? ....... NO But can't figure out how to get the format command to see them so I know they've been detected by the system.

    Read the article

  • Smart Array P400 battery failure

    - by RobIII
    The P400 Smart Array controller in my HP DL380G5 is indicating: Battery Status: Failed, Replace Battery 1 in the System Management Homepage. Also the IML indicates: POST Error: 1794-Drive Array - Array Accelerator Battery Charge Low I do have several replacement batteries (actually, several controllers including batteries) lying around at work but never had to actually replace one. I am wondering if the battery replacement (swap) could be done hot or if I need to take down my server to do the battery replacement. I have replaced other spare parts like fans and drives before and all those can be replaced hot. I just don't know about the battery of the P400 Smart Array controller. Any help would be appreciated. EDIT1 For those interested: straight from the horse's mouth: With thanks to Frands Hansen pointing it out here. EDIT2 In the end I did just power down, to be on the safe side and because the manual says so, and replace the battery. Couldn't be easier. Unplugged the old one of the end of the cable (not the end connected to the controller) and reconnected a spare one. The replaced battery is now in the server for about an hour and currently (still) recharging. I'm assuming all will end wel.

    Read the article

  • Formatting an HP ProLiant dl380 G4

    - by i.h4d35
    I have an old HP ProLiant dl380 G4 server whose hard disk needs to be formatted. Unfortunately, I cannot seem to do so. For one, it doesn't seem to be detecting any Hard Drives attached to the Server. The Hard Disks show up in the Ctrl+A option (SCSI Configuration Utility). Also, while inserting the SmartStart CD (7.01 or 7.04), it shows a message that no logical drives are found and there aren't any options to create one. Alternately I've tried slipstreaming the SCSI Driver into the OS but that doesn't seem to be helping. Also, I have a USB Floppy drive (for the SCSI driver) but that doesn't seem to be detected. Also, directly installing the OS (MS Server 2003 Standard Edition) obviously doesn't work (shows no hard disk found) Could anyone please advise as to what other needs to be done to format my server? Also please tell me what are the possible errors/mistakes which've been made so that I can learn from them. I went through some questions here on ServerFault and the HP guides here but they weren't of much help to a n00b like me. Thanks in Advance.

    Read the article

  • Disabling RAID feature on HP Smart Array P400

    - by Arie K
    I'm planning to use ZFS on my system (HP ML370 G5, Smart Array P400, 8 SAS disk). I want ZFS to manage all disks individually, so it can utilize better scheduling (i.e. I want to use software RAID feature in ZFS). The problem is, I can't find a way to disable RAID feature on the RAID controller. Right now, the controller aggregates all of the disks into one big RAID-5 volume. So ZFS can't see individual disk. Is there any way to acomplish this setup?

    Read the article

  • HP ProLiant Smart Array "lock up" code 0x11

    - by ewwhite
    I've a ProLiant DL580 G7 server that experienced a storage subsystem failure during production. The system appeared available and responded to pings, but all I/O access stalled (the system load must have been 100+). The ASR did not trigger at the specified watchdog timeout. I had to force a reboot from the ILO. During POST, I received the following error: A controller failure event occurred prior to this power-up. (Previous lock up code = 0x11) I haven't pulled the ADU report yet, but I'm curious as to what this error actually means. I was not responsible for the the installation, but can see that the firmware is very old. But if there's anything else I should know about the error, I'd like to know for the post-mortem report. edit - I should add that the server had 95 days of uptime prior to the lock up.

    Read the article

  • RAID P410i and P812 performance issues

    - by Alexey
    I'm having much trouble with I/O performance of HP DL360 server with two RAID controllers - P410i and P812, Windows Server 2008, 36 GiB RAM and 16 x Intel Xeon x5550. The server runs a bunch of tasks producing heavy sequential I/O, and after about 20-30 minutes of intensive work it looks like the tasks are stuck, not using CPU and with enough free memory (so this cannot be a bottleneck). The same tasks were running quite well on the older server (Windows Server 2003, 4 x Intel Xeon, 12 GiB RAM). RAID cache is present, write-cache battery is installed. Cache is configured as 25% readahead/75% writeback. The swap file resides on the logical disk served by P410i and other logical disks are on P812. Can someone tell me what can be the matter of this? Is this a hardware problem or misconfiguration?

    Read the article

  • how to initialize two logical drives on a HP P400i controller without reboot

    - by John
    What I am trying to do is initialize two logical drives on a HP P400i embedded controller without a reboot of the system here my current Array config: array A (SAS, Unused Space: 0 MB) logicaldrive 1 (17.9 GB, RAID 5, OK) logicaldrive 2 (17.9 GB, RAID 5, OK) logicaldrive 3 (75.9 GB, RAID 5, OK) logicaldrive 4 (25.0 GB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 5 (99 MB, RAID 0, OK) logicaldrive 6 (68.2 GB, RAID 0, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK) windows 2003 machine running the HpCISs2.sys driver version 6.20.0.32 . I have the ACU and ACU CLI tools installed version 8.28.13.0, P400i firmware version 2.74 . Now what I'd like to do is removes the physical drive 1I:1:4 and delete the two logical drives in array B. then insert a new drive in to bay 4 that contains two new logical drives and have them show up in array B again. So far after I remove the drive and delete the failed logical drives, I insert the new drive and run HPacucli rescan. I get the new drive to show up as unassinged physical drive but I cant figure out now to "for lack of a better word" mount the 2 logical drives on the new unassinged disk. If I reboot the system the array controller picks up the new fourth drive and creates Array B with the drives without problem but I'd really like to not have to reboot the server. Any ideas?

    Read the article

  • moving raid 10 to another identical server both on Smart Array 6i controllers

    - by SalimQrdl
    I have dead HP DL 380G4 with RAID 1+0 with 1 logical volume from 4x72GB drives on built-in Smart Array 6i 128Mb BBWC. It was shut down properly. It seems it was usual death for Proliant with ILO led 2,3,8 lighting. I want to move array to another identical server with same raid firmware level. What is the best strategy?: I have RAID 1+0 on bay 0 bay 1 bay 2 bay 3 As I understand bay0+bay1 are in RAID 1 , bay2+bay3 are in RAID 1, and both RAID 1 pairs are in RAID 0. So should I : Clear RAID config on new server, insert bay 0, bay 2 and power-on or Create RAID 1+0 with 1 logical volume from clear HDDs , and then poweroff ,remove HDDs and insert 2 HDDs(bay 0, bay 2) from old RAID 1+0. then power-on. (each hdd has its raid position info stored but may be could work on same config) According to documentation for Smart Array 6i it could be possible to migrate. however one requirement point is unclear for me Before you move drives, the following conditions must be met: • The array is in its original configuration. " What is orginal and non-original config for RAID 1+0? Another point "If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time." I want to move one hdd from each RAID 1 pair. to have mirrors untouched just in case. Do they mean to move all 4 simultaniously? Smart Array 6i User Guide: Moving Drives and Arrays You can move drives to other ID positionson the same array controller. You can also move a complete arrayfrom one controller to another, even if the controllers are on different servers. Before you move drives, the following conditions must be met: • If moving thedrives to a different server, the new server must have enough empty bays to accommodate all the drives simultaneously. • The move will not result in more than 14 physical drives per controller channel. • No controller will be configured with more than 32 logical volumes. • The array has no failed or missing drives. • The array is in its original configuration. • The controller is not reading from or writing to any of the spare drives in the array. • The controller is not running capacity expansion, capacity extension, or RAID or stripe size migration. • The controller is using the latestfirmware version (recommended). If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time. • In most cases, a moved array (and the logical drives that it contains) can still undergo arraycapacity expansion, logical drive capacity extension, or migration of RAID level orstripe size. When all the conditions have been met: Back up all data before removing any drives or changing configuration. This step is requiredif you are moving data-containing drives from a controller that does not have a battery-backed cache. Power down the system. If you are moving an array from a controller that contains a RAID ADG logical volume to a controller that does not support RAID ADG: Move the drives. Power up the system. If a 1724 POST message is displayed, drive positions were changed successfully and the configuration was updated. If a 1785 (NotConfigured)POST message is displayed: a. Power down the system immediately to prevent data loss. b. Return the drives to their original locations. c. Restore the data from backup, if necessary. Check the new drive configuration byrunning ORCA or ACU ("Configuring an Array" on page 9).

    Read the article

  • Ubuntu 12.04 - HP ProLiant DL380 G4 - Load Maxes Out / Unresponsive

    - by Brian S
    Trying to post this question on here. I've posted it on the Ubuntu forums as well with no replies. Recently I upgraded an HP ProLiant DL380 G4 server from Ubuntu 10.04 server to Ubuntu 12.04 server. Upon doing so, the server will not - at random times - get to a load of 400+ and then become completely non-responsive. I use an SNMP graphing program (cacti) and the load steadily increases by about 10 every five minutes until it gets over 400 and the graphing stops. The graphs may not be accurate, but the CPU load averages about 3% before this happens - and right when the load starts increasing, it jumps to about 25% for 15 minutes and dramatically dips down to less than 1% (about 0.3%) until the graphing stops. I'm not able to open a SSH tunnel to the server to do anything. I've checked the /var/log/syslog and all logging stops at that time as well - with nothing else in there. The odd thing is - the server still responds to DNS queries for the zones it is authoritative on during this time - and at normal speed. Just not sure what the next step would be in order to find out what is going on - and how this issue can be corrected. The server cannot stay with Ubuntu 10.04 Server and needs to stay upgraded.

    Read the article

  • Can I use a Smart Array P410 controller on a HP Proliant DL 180 G5 server?

    - by Massimo
    This link says the HP Proliant DL 180 G5 server only supports Smart Array E200, E500, P400 and P800 controllers. Can I use a Smart Array P410 instead? Currently the server has only the default internal controller, I need an additional one for better performance and to support additional drives (the default controller only supports 4, with a Smart Array controller all 8 bays can be used). The disks are SATA ones.

    Read the article

1 2  | Next Page >