  • I would like to prevent these entries from being added to the eventlog.

    - by David Smith
    Our client's application EventLog is getting filled up with warnings due to a bug in the Microsoft SQL Server report viewer control, http://support.microsoft.com/kb/973219. They have thousands of users running reports so this is making their eventlog hard to use and they want them removed on a frequent basis. I tried using PowerShell to remove the events, but that does not seem possible. Is there a way to prevent these entries from being written to the event log in the first place? I'm thinking I would like to filter out events where event source="ASP.NET 2.0.50727.0", eventId ="1309" and Message contains "Reserved.ReportViewerWebControl.axd"

    Read the article

  • Event Log "Wake Source" when system wakes from sleep

    - by Doltknuckle
    So I've been troubleshooting sleep timers for our systems and have run across an interesting issue. I need a way to report how long a system was awake after a number of different inputs. Now, I've discovered that the System Log tracks wake and sleep events and even tells you the times that everything happens at. The thing is doesn't tell you is what triggered the wake event. It does give you a numerical code however. Here are some examples of what I am finding. Index : 2901 EntryType : Information InstanceId : 1 Message : The system has resumed from sleep. Sleep Time: 2010-10-01T23:20:06.097488100Z Wake Time: 2010-10-03T17:41:12.796400500Z Wake Source: 0 Category : (0) CategoryNumber : 0 Source : Microsoft-Windows-Power-Troubleshooter -- Index : 2841 EntryType : Information InstanceId : 1 Message : The system has resumed from sleep. Sleep Time: 2010-10-01T19:19:37.239789600Z Wake Time: 2010-10-01T21:28:48.921200800Z Wake Source: 4HID Keyboard Device Category : (0) CategoryNumber : 0 Source : Microsoft-Windows-Power-Troubleshooter So here's my question: Does anyone know what the different numerical codes for the "Wake Source" mean? I think "0" is a magic packet and "4" is a USB device. Does anyone have any idea if there is any documentation out there on this for Windows 7? Thanks in advance

    Read the article

  • Shrinking the transaction log of a mirrored SQL Server 2005 database

    - by Peter Di Cecco
    I've been looking all over the internet and I can't find an acceptable solution to my problem, I'm wondering if there even is a solution without a compromise... I'm not a DBA, but I'm a one man team working on a huge web site with no extra funding for extra bodies, so I'm doing the best I can. Our backup plan sucks, and I'm having a really hard time improving it. Currently, there are two servers running SQL Server 2005. I have a mirrored database (no witness) that seems to be working well. I do a full backup at noon and at midnight. These get backed up to tape by our service provider nightly, and I burn the backup files to dvd weekly to keep old records on hand. Eventually I'd like to switch to log shipping, since mirroring seems kinda pointless without a witness server. The issue is that the transaction log is growing non-stop. From the research I've done, it seems that I can't truncate a log file of a mirrored database. So how do I stop the file from growing!? Based on this web page, I tried this: USE dbname GO CHECKPOINT GO BACKUP LOG dbname TO DISK='NULL' WITH NOFORMAT, INIT, NAME = N'dbnameLog Backup', SKIP, NOREWIND, NOUNLOAD GO DBCC SHRINKFILE('dbname_Log', 2048) GO But that didn't work. Everything else I've found says I need to disable the mirror before running the backup log command in order for it to work. My Question (TL;DR) How can I shrink my transaction log file without disabling the mirror?

    Read the article

  • Event ID 9331 MSExchangeSA & Event ID 9335 MSExchangeSA

    - by George
    I get this two Exchange 2010 Global Address book related event IDs: Event ID 9331 MSExchangeSA OABGen encountered error 80004005 (internal ID 50101f1) accessing the public folder database while generating the offline address list for address list '/'. -\Default Offline Address List and Event ID 9335 MSExchangeSA OABGen encountered error 80004005 while cleaning the offline address list public folders under /o=xxxxx xxxx/cn=addrlists/cn=oabs/cn=Default Offline Address List. Please make sure the public folder database is mounted and replicas exist of the offline address list folders. No offline address lists have been generated. Please check the event log for more information. -\Default Offline Address List It is Exchange 2010 SP2 sitting on Windows 2008 enterprise edition. Essentially the issue is that the global address book is not being updated on Outlook clients. We are using Outlook 2007 and 2010. So far I have tried running the following command: Update-FileDistributionService -Identity ExchangeServer -Type "OAB" And I tried this solution as well: 1) Make sure the Microsoft Exchange System Attendant is running. It will be set to start automatically by default, but it doesn't. This is a known issue. Start this service manually. When running, you will not get an error when trying to update the GAL. 2) "Apply" any changes made to any address lists before the GAL will update Outlook properly. In Organization Configuration - Mailbox in EMC, view the properties of the Default Global Address Book in the Offline Address Book tab. In the properties window, select the Address Lists tab. This shows which address lists makes up the GAL. 3) Close the properties window and select the Address Lists tab in the Organization Configuration - Mailbox. Right-click each address list used by the Def GAL and click "Apply" (make sure the "Immediately" radio button is checked). 4) Last, go back to the Offline Address Book tab, right-click the GAL and select "Update". After a few send/receives in the Outlook clients, their Glogal Address List should update to show the latest changes. Neither one of those solutions helped. So I am not really sure what to do here. Also, I am aware of changing registry on each local computers, but it would be close to impossible as we have 8 offices in 3 different countries. Any suggestions? EDIT 7.XII.2012 @ 10.35 I forgot to mention that we did rebuild the address book and that didn't help.

    Read the article

  • 40k Event Log Errors an hour Unknown Username or bad password

    - by ErocM
    I am getting about 200k of these an hour: An account failed to log on. Subject: Security ID: SYSTEM Account Name: TGSERVER$ Account Domain: WORKGROUP Logon ID: 0x3e7 Logon Type: 4 Account For Which Logon Failed: Security ID: NULL SID Account Name: administrator Account Domain: TGSERVER Failure Information: Failure Reason: Unknown user name or bad password. Status: 0xc000006d Sub Status: 0xc0000064 Process Information: Caller Process ID: 0x334 Caller Process Name: C:\Windows\System32\svchost.exe Network Information: Workstation Name: TGSERVER Source Network Address: - Source Port: - Detailed Authentication Information: Logon Process: Advapi Authentication Package: Negotiate Transited Services: - Package Name (NTLM only): - Key Length: 0 This event is generated when a logon request fails. It is generated on the computer where access was attempted. The Subject fields indicate the account on the local system which requested the logon. This is most commonly a service such as the Server service, or a local process such as Winlogon.exe or Services.exe. The Logon Type field indicates the kind of logon that was requested. The most common types are 2 (interactive) and 3 (network). The Process Information fields indicate which account and process on the system requested the logon. The Network Information fields indicate where a remote logon request originated. Workstation name is not always available and may be left blank in some cases. The authentication information fields provide detailed information about this specific logon request. - Transited services indicate which intermediate services have participated in this logon request. - Package name indicates which sub-protocol was used among the NTLM protocols. - Key length indicates the length of the generated session key. This will be 0 if no session key was requested. On my server... I changed my adminstrative username to something else and since then I've been inidated with these messages. I found on http://technet.microsoft.com/en-us/library/cc787567(v=WS.10).aspx that the 4 means "Batch logon type is used by batch servers, where processes may be executing on behalf of a user without their direct intervention." which really doesn't shed any light on it for me. I checked the services and they are all logging in as local system or network service. Nothing for administrator. Anyone have any idea how I tell where these are coming from? I would assume this is a program that is crapping out... Thanks in advance!

    Read the article

  • Try a sample: Using the counter predicate for event sampling

    - by extended_events
    Extended Events offers a rich filtering mechanism, called predicates, that allows you to reduce the number of events you collect by specifying criteria that will be applied during event collection. (You can find more information about predicates in Using SQL Server 2008 Extended Events (by Jonathan Kehayias)) By evaluating predicates early in the event firing sequence we can reduce the performance impact of collecting events by stopping event collection when the criteria are not met. You can specify predicates on both event fields and on a special object called a predicate source. Predicate sources are similar to action in that they typically are related to some type of global information available from the server. You will find that many of the actions available in Extended Events have equivalent predicate sources, but actions and predicates sources are not the same thing. Applying predicates, whether on a field or predicate source, is very similar to what you are used to in T-SQL in terms of how they work; you pick some field/source and compare it to a value, for example, session_id = 52. There is one predicate source that merits special attention though, not just for its special use, but for how the order of predicate evaluation impacts the behavior you see. I’m referring to the counter predicate source. The counter predicate source gives you a way to sample a subset of events that otherwise meet the criteria of the predicate; for example you could collect every other event, or only every tenth event. Simple CountingThe counter predicate source works by creating an in memory counter that increments every time the predicate statement is evaluated. Here is a simple example with my favorite event, sql_statement_completed, that only collects the second statement that is run. (OK, that’s not much of a sample, but this is for demonstration purposes. Here is the session definition: CREATE EVENT SESSION counter_test ON SERVERADD EVENT sqlserver.sql_statement_completed    (ACTION (sqlserver.sql_text)    WHERE package0.counter = 2)ADD TARGET package0.ring_bufferWITH (MAX_DISPATCH_LATENCY = 1 SECONDS) You can find general information about the session DDL syntax in BOL and from Pedro’s post Introduction to Extended Events. The important part here is the WHERE statement that defines that I only what the event where package0.count = 2; in other words, only the second instance of the event. Notice that I need to provide the package name along with the predicate source. You don’t need to provide the package name if you’re using event fields, only for predicate sources. Let’s say I run the following test queries: -- Run three statements to test the sessionSELECT 'This is the first statement'GOSELECT 'This is the second statement'GOSELECT 'This is the third statement';GO Once you return the event data from the ring buffer and parse the XML (see my earlier post on reading event data) you should see something like this: event_name sql_text sql_statement_completed SELECT ‘This is the second statement’ You can see that only the second statement from the test was actually collected. (Feel free to try this yourself. Check out what happens if you remove the WHERE statement from your session. Go ahead, I’ll wait.) Percentage Sampling OK, so that wasn’t particularly interesting, but you can probably see that this could be interesting, for example, lets say I need a 25% sample of the statements executed on my server for some type of QA analysis, that might be more interesting than just the second statement. All comparisons of predicates are handled using an object called a predicate comparator; the simple comparisons such as equals, greater than, etc. are mapped to the common mathematical symbols you know and love (eg. = and >), but to do the less common comparisons you will need to use the predicate comparators directly. You would probably look to the MOD operation to do this type sampling; we would too, but we don’t call it MOD, we call it divides_by_uint64. This comparator evaluates whether one number is divisible by another with no remainder. The general syntax for using a predicate comparator is pred_comp(field, value), field is always first and value is always second. So lets take a look at how the session changes to answer our new question of 25% sampling: CREATE EVENT SESSION counter_test_25 ON SERVERADD EVENT sqlserver.sql_statement_completed    (ACTION (sqlserver.sql_text)    WHERE package0.divides_by_uint64(package0.counter,4))ADD TARGET package0.ring_bufferWITH (MAX_DISPATCH_LATENCY = 1 SECONDS)GO Here I’ve replaced the simple equivalency check with the divides_by_uint64 comparator to check if the counter is evenly divisible by 4, which gives us back every fourth record. I’ll leave it as an exercise for the reader to test this session. Why order matters I indicated at the start of this post that order matters when it comes to the counter predicate – it does. Like most other predicate systems, Extended Events evaluates the predicate statement from left to right; as soon as the predicate statement is proven false we abandon evaluation of the remainder of the statement. The counter predicate source is only incremented when it is evaluated so whether or not the counter is incremented will depend on where it is in the predicate statement and whether a previous criteria made the predicate false or not. Here is a generic example: Pred1: (WHERE statement_1 AND package0.counter = 2)Pred2: (WHERE package0.counter = 2 AND statement_1) Let’s say I cause a number of events as follows and examine what happens to the counter predicate source. Iteration Statement Pred1 Counter Pred2 Counter A Not statement_1 0 1 B statement_1 1 2 C Not statement_1 1 3 D statement_1 2 4 As you can see, in the case of Pred1, statement_1 is evaluated first, when it fails (A & C) predicate evaluation is stopped and the counter is not incremented. With Pred2 the counter is evaluated first, so it is incremented on every iteration of the event and the remaining parts of the predicate are then evaluated. In this example, Pred1 would return an event for D while Pred2 would return an event for B. But wait, there is an interesting side-effect here; consider Pred2 if I had run my statements in the following order: Not statement_1 Not statement_1 statement_1 statement_1 In this case I would never get an event back from the system because the point at which counter=2, the rest of the predicate evaluates as false so the event is not returned. If you’re using the counter target for sampling and you’re not getting the expected events, or any events, check the order of the predicate criteria. As a general rule I’d suggest that the counter criteria should be the last element of your predicate statement since that will assure that your sampling rate will apply to the set of event records defined by the rest of your predicate. Aside: I’m interested in hearing about uses for putting the counter predicate criteria earlier in the predicate statement. If you have one, post it in a comment to share with the class. - Mike Share this post: email it! | bookmark it! | digg it! | reddit! | kick it! | live it!

    Read the article

  • help with fixing fwts errors log

    - by jasmines
    Here is an extract of results.log: MTRR validation. Test 1 of 3: Validate the kernel MTRR IOMEM setup. FAILED [MEDIUM] MTRRIncorrectAttr: Test 1, Memory range 0xc0000000 to 0xdfffffff (PCI Bus 0000:00) has incorrect attribute Write-Combining. FAILED [MEDIUM] MTRRIncorrectAttr: Test 1, Memory range 0xfee01000 to 0xffffffff (PCI Bus 0000:00) has incorrect attribute Write-Protect. ==================================================================================================== Test 1 of 1: Kernel log error check. Kernel message: [ 0.208079] [Firmware Bug]: ACPI: BIOS _OSI(Linux) query ignored ADVICE: This is not exactly a failure mode but a warning from the kernel. The _OSI() method has implemented a match to the 'Linux' query in the DSDT and this is redundant because the ACPI driver matches onto the Windows _OSI strings by default. FAILED [HIGH] KlogACPIErrorMethodExecutionParse: Test 1, HIGH Kernel message: [ 3.512783] ACPI Error : Method parse/execution failed [\_SB_.PCI0.GFX0._DOD] (Node f7425858), AE_AML_PACKAGE_LIMIT (20110623/psparse-536) ADVICE: This is a bug picked up by the kernel, but as yet, the firmware test suite has no diagnostic advice for this particular problem. Found 1 unique errors in kernel log. ==================================================================================================== Check if system is using latest microcode. ---------------------------------------------------------------------------------------------------- Cannot read microcode file /usr/share/misc/intel-microcode.dat. Aborted test, initialisation failed. ==================================================================================================== MSR register tests. FAILED [MEDIUM] MSRCPUsInconsistent: Test 1, MSR SYSENTER_ESP (0x175) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0xffffffffffffffff). MSR CPU 0 -> 0xf7bb9c40 vs CPU 1 -> 0xf7bc7c40 FAILED [MEDIUM] MSRCPUsInconsistent: Test 1, MSR MISC_ENABLE (0x1a0) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0x400c51889). MSR CPU 0 -> 0x850088 vs CPU 1 -> 0x850089 ==================================================================================================== Checks firmware has set PCI Express MaxReadReq to a higher value on non-motherboard devices. ---------------------------------------------------------------------------------------------------- Test 1 of 1: Check firmware settings MaxReadReq for PCI Express devices. MaxReadReq for pci://00:00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) is low (128) [Audio device]. MaxReadReq for pci://00:02:00.0 Network controller: Intel Corporation PRO/Wireless 5100 AGN [Shiloh] Network Connection is low (128) [Network controller]. FAILED [LOW] LowMaxReadReq: Test 1, 2 devices have low MaxReadReq settings. Firmware may have configured these too low. ADVICE: The MaxReadRequest size is set too low and will affect performance. It will provide excellent bus sharing at the cost of bus data transfer rates. Although not a critical issue, it may be worth considering setting the MaxReadRequest size to 256 or 512 to increase throughput on the PCI Express bus. Some drivers (for example the Brocade Fibre Channel driver) allow one to override the firmware settings. Where possible, this BIOS configuration setting is worth increasing it a little more for better performance at a small reduction of bus sharing. ==================================================================================================== PCIe ASPM check. ---------------------------------------------------------------------------------------------------- Test 1 of 2: PCIe ASPM ACPI test. PCIE ASPM is not controlled by Linux kernel. ADVICE: BIOS reports that Linux kernel should not modify ASPM settings that BIOS configured. It can be intentional because hardware vendors identified some capability bugs between the motherboard and the add-on cards. Test 2 of 2: PCIe ASPM registers test. WARNING: Test 2, RP 00h:1Ch.01h L0s not enabled. WARNING: Test 2, RP 00h:1Ch.01h L1 not enabled. WARNING: Test 2, Device 02h:00h.00h L0s not enabled. WARNING: Test 2, Device 02h:00h.00h L1 not enabled. PASSED: Test 2, PCIE aspm setting matched was matched. WARNING: Test 2, RP 00h:1Ch.05h L0s not enabled. WARNING: Test 2, RP 00h:1Ch.05h L1 not enabled. WARNING: Test 2, Device 85h:00h.00h L0s not enabled. WARNING: Test 2, Device 85h:00h.00h L1 not enabled. PASSED: Test 2, PCIE aspm setting matched was matched. ==================================================================================================== Extract and analyse Windows Management Instrumentation (WMI). Test 1 of 2: Check Windows Management Instrumentation in DSDT Found WMI Method WMAA with GUID: 5FB7F034-2C63-45E9-BE91-3D44E2C707E4, Instance 0x01 Found WMI Event, Notifier ID: 0x80, GUID: 95F24279-4D7B-4334-9387-ACCDC67EF61C, Instance 0x01 PASSED: Test 1, GUID 95F24279-4D7B-4334-9387-ACCDC67EF61C is handled by driver hp-wmi (Vendor: HP). Found WMI Event, Notifier ID: 0xa0, GUID: 2B814318-4BE8-4707-9D84-A190A859B5D0, Instance 0x01 FAILED [MEDIUM] WMIUnknownGUID: Test 1, GUID 2B814318-4BE8-4707-9D84-A190A859B5D0 is unknown to the kernel, a driver may need to be implemented for this GUID. ADVICE: A WMI driver probably needs to be written for this event. It can checked for using: wmi_has_guid("2B814318-4BE8-4707-9D84-A190A859B5D0"). One can install a notify handler using wmi_install_notify_handler("2B814318-4BE8-4707-9D84-A190A859B5D0", handler, NULL). http://lwn.net/Articles/391230 describes how to write an appropriate driver. Found WMI Object, Object ID AB, GUID: 05901221-D566-11D1-B2F0-00A0C9062910, Instance 0x01, Flags: 00 Found WMI Method WMBA with GUID: 1F4C91EB-DC5C-460B-951D-C7CB9B4B8D5E, Instance 0x01 Found WMI Object, Object ID BC, GUID: 2D114B49-2DFB-4130-B8FE-4A3C09E75133, Instance 0x7f, Flags: 00 Found WMI Object, Object ID BD, GUID: 988D08E3-68F4-4C35-AF3E-6A1B8106F83C, Instance 0x19, Flags: 00 Found WMI Object, Object ID BE, GUID: 14EA9746-CE1F-4098-A0E0-7045CB4DA745, Instance 0x01, Flags: 00 Found WMI Object, Object ID BF, GUID: 322F2028-0F84-4901-988E-015176049E2D, Instance 0x01, Flags: 00 Found WMI Object, Object ID BG, GUID: 8232DE3D-663D-4327-A8F4-E293ADB9BF05, Instance 0x01, Flags: 00 Found WMI Object, Object ID BH, GUID: 8F1F6436-9F42-42C8-BADC-0E9424F20C9A, Instance 0x00, Flags: 00 Found WMI Object, Object ID BI, GUID: 8F1F6435-9F42-42C8-BADC-0E9424F20C9A, Instance 0x00, Flags: 00 Found WMI Method WMAC with GUID: 7391A661-223A-47DB-A77A-7BE84C60822D, Instance 0x01 Found WMI Object, Object ID BJ, GUID: DF4E63B6-3BBC-4858-9737-C74F82F821F3, Instance 0x05, Flags: 00 ==================================================================================================== Disassemble DSDT to check for _OSI("Linux"). ---------------------------------------------------------------------------------------------------- Test 1 of 1: Disassemble DSDT to check for _OSI("Linux"). This is not strictly a failure mode, it just alerts one that this has been defined in the DSDT and probably should be avoided since the Linux ACPI driver matches onto the Windows _OSI strings { If (_OSI ("Linux")) { Store (0x03E8, OSYS) } If (_OSI ("Windows 2001")) { Store (0x07D1, OSYS) } If (_OSI ("Windows 2001 SP1")) { Store (0x07D1, OSYS) } If (_OSI ("Windows 2001 SP2")) { Store (0x07D2, OSYS) } If (_OSI ("Windows 2006")) { Store (0x07D6, OSYS) } If (LAnd (MPEN, LEqual (OSYS, 0x07D1))) { TRAP (0x01, 0x48) } TRAP (0x03, 0x35) } WARNING: Test 1, DSDT implements a deprecated _OSI("Linux") test. ==================================================================================================== 0 passed, 0 failed, 1 warnings, 0 aborted, 0 skipped, 0 info only. ==================================================================================================== ACPI DSDT Method Semantic Tests. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP Failed to install global event handler. Test 22 of 93: Check _PSR (Power Source). ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 22, Detected an infinite loop when evaluating method '\_SB_.AC__._PSR'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 22, \_SB_.AC__._PSR correctly acquired and released locks 16 times. Test 35 of 93: Check _TMP (Thermal Zone Current Temp). ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.DTSZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.DTSZ._TMP correctly acquired and released locks 14 times. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.CPUZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.CPUZ._TMP correctly acquired and released locks 10 times. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 35, Detected an infinite loop when evaluating method '\_TZ_.SKNZ._TMP'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. PASSED: Test 35, \_TZ_.SKNZ._TMP correctly acquired and released locks 10 times. PASSED: Test 35, _TMP correctly returned sane looking value 0x00000b4c (289.2 degrees K) PASSED: Test 35, \_TZ_.BATZ._TMP correctly acquired and released locks 9 times. PASSED: Test 35, _TMP correctly returned sane looking value 0x00000aac (273.2 degrees K) PASSED: Test 35, \_TZ_.FDTZ._TMP correctly acquired and released locks 7 times. Test 46 of 93: Check _DIS (Disable). FAILED [MEDIUM] MethodShouldReturnNothing: Test 46, \_SB_.PCI0.LPCB.SIO_.COM1._DIS returned values, but was expected to return nothing. Object returned: INTEGER: 0x00000000 ADVICE: This probably won't cause any errors, but it should be fixed as the AML code is not conforming to the expected behaviour as described in the ACPI specification. FAILED [MEDIUM] MethodShouldReturnNothing: Test 46, \_SB_.PCI0.LPCB.SIO_.LPT0._DIS returned values, but was expected to return nothing. Object returned: INTEGER: 0x00000000 ADVICE: This probably won't cause any errors, but it should be fixed as the AML code is not conforming to the expected behaviour as described in the ACPI specification. Test 61 of 93: Check _WAK (System Wake). Test _WAK(1) System Wake, State S1. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(2) System Wake, State S2. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(3) System Wake, State S3. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(4) System Wake, State S4. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test _WAK(5) System Wake, State S5. ACPICA Exception AE_AML_INFINITE_LOOP during execution of method COMP WARNING: Test 61, Detected an infinite loop when evaluating method '\_WAK'. ADVICE: This may occur because we are emulating the execution in this test environment and cannot handshake with the embedded controller or jump to the BIOS via SMIs. However, the fact that AML code spins forever means that lockup conditions are not being checked for in the AML bytecode. Test 87 of 93: Check _BCL (Query List of Brightness Control Levels Supported). Package has 2 elements: 00: INTEGER: 0x00000000 01: INTEGER: 0x00000000 FAILED [MEDIUM] Method_BCLElementCount: Test 87, Method _BCL should return a package of more than 2 integers, got just 2. Test 88 of 93: Check _BCM (Set Brightness Level). ACPICA Exception AE_AML_PACKAGE_LIMIT during execution of method _BCM FAILED [CRITICAL] AEAMLPackgeLimit: Test 88, Detected error 'Package limit' when evaluating '\_SB_.PCI0.GFX0.DD02._BCM'. ==================================================================================================== ACPI table settings sanity checks. ---------------------------------------------------------------------------------------------------- Test 1 of 1: Check ACPI tables. PASSED: Test 1, Table APIC passed. Table ECDT not present to check. FAILED [MEDIUM] FADT32And64BothDefined: Test 1, FADT 32 bit FIRMWARE_CONTROL is non-zero, and X_FIRMWARE_CONTROL is also non-zero. Section 5.2.9 of the ACPI specification states that if the FIRMWARE_CONTROL is non-zero then X_FIRMWARE_CONTROL must be set to zero. ADVICE: The FADT FIRMWARE_CTRL is a 32 bit pointer that points to the physical memory address of the Firmware ACPI Control Structure (FACS). There is also an extended 64 bit version of this, the X_FIRMWARE_CTRL pointer that also can point to the FACS. Section 5.2.9 of the ACPI specification states that if the X_FIRMWARE_CTRL field contains a non zero value then the FIRMWARE_CTRL field *must* be zero. This error is also detected by the Linux kernel. If FIRMWARE_CTRL and X_FIRMWARE_CTRL are defined, then the kernel just uses the 64 bit version of the pointer. PASSED: Test 1, Table HPET passed. PASSED: Test 1, Table MCFG passed. PASSED: Test 1, Table RSDT passed. PASSED: Test 1, Table RSDP passed. Table SBST not present to check. PASSED: Test 1, Table XSDT passed. ==================================================================================================== Re-assemble DSDT and find syntax errors and warnings. ---------------------------------------------------------------------------------------------------- Test 1 of 2: Disassemble and reassemble DSDT FAILED [HIGH] AMLAssemblerError4043: Test 1, Assembler error in line 2261 Line | AML source ---------------------------------------------------------------------------------------------------- 02258| 0x00000000, // Range Minimum 02259| 0xFEDFFFFF, // Range Maximum 02260| 0x00000000, // Translation Offset 02261| 0x00000000, // Length | ^ | error 4043: Invalid combination of Length and Min/Max fixed flags 02262| ,, _Y0E, AddressRangeMemory, TypeStatic) 02263| DWordMemory (ResourceProducer, PosDecode, MinFixed, MaxFixed, Cacheable, ReadWrite, 02264| 0x00000000, // Granularity ==================================================================================================== ADVICE: (for error #4043): This occurs if the length is zero and just one of the resource MIF/MAF flags are set, or the length is non-zero and resource MIF/MAF flags are both set. These are illegal combinations and need to be fixed. See section 6.4.3.5 Address Space Resource Descriptors of version 4.0a of the ACPI specification for more details. FAILED [HIGH] AMLAssemblerError4050: Test 1, Assembler error in line 2268 Line | AML source ---------------------------------------------------------------------------------------------------- 02265| 0xFEE01000, // Range Minimum 02266| 0xFFFFFFFF, // Range Maximum 02267| 0x00000000, // Translation Offset 02268| 0x011FEFFF, // Length | ^ | error 4050: Length is not equal to fixed Min/Max window 02269| ,, , AddressRangeMemory, TypeStatic) 02270| }) 02271| Method (_CRS, 0, Serialized) ==================================================================================================== ADVICE: (for error #4050): The minimum address is greater than the maximum address. This is illegal. FAILED [HIGH] AMLAssemblerError1104: Test 1, Assembler error in line 8885 Line | AML source ---------------------------------------------------------------------------------------------------- 08882| Method (_DIS, 0, NotSerialized) 08883| { 08884| DSOD (0x02) 08885| Return (0x00) | ^ | warning level 0 1104: Reserved method should not return a value (_DIS) 08886| } 08887| 08888| Method (_SRS, 1, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 1, Assembler error in line 9195 Line | AML source ---------------------------------------------------------------------------------------------------- 09192| Method (_DIS, 0, NotSerialized) 09193| { 09194| DSOD (0x01) 09195| Return (0x00) | ^ | warning level 0 1104: Reserved method should not return a value (_DIS) 09196| } 09197| 09198| Method (_SRS, 1, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1127: Test 1, Assembler error in line 9242 Line | AML source ---------------------------------------------------------------------------------------------------- 09239| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y21._MAX, MAX2) 09240| CreateByteField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y21._LEN, LEN2) 09241| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y22._INT, IRQ0) 09242| CreateWordField (CRES, \_SB.PCI0.LPCB.SIO.LPT0._CRS._Y23._DMA, DMA0) | ^ | warning level 0 1127: ResourceTag smaller than Field (Tag: 8 bits, Field: 16 bits) 09243| If (RLPD) 09244| { 09245| Store (0x00, Local0) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1128: Test 1, Assembler error in line 18682 Line | AML source ---------------------------------------------------------------------------------------------------- 18679| Store (0x01, Index (DerefOf (Index (Local0, 0x02)), 0x01)) 18680| If (And (WDPE, 0x40)) 18681| { 18682| Wait (\_SB.BEVT, 0x10) | ^ | warning level 0 1128: Result is not used, possible operator timeout will be missed 18683| } 18684| 18685| Store (BRID, Index (DerefOf (Index (Local0, 0x02)), 0x02)) ==================================================================================================== ADVICE: (for warning level 0 #1128): The operation can possibly timeout, and hence the return value indicates an timeout error. However, because the return value is not checked this very probably indicates that the code is buggy. A possible scenario is that a mutex times out and the code attempts to access data in a critical region when it should not. This will lead to undefined behaviour. This should be fixed. Table DSDT (0) reassembly: Found 2 errors, 4 warnings. Test 2 of 2: Disassemble and reassemble SSDT PASSED: Test 2, SSDT (0) reassembly, Found 0 errors, 0 warnings. FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 60 Line | AML source ---------------------------------------------------------------------------------------------------- 00057| { 00058| Store (CPDC (Arg0), Local0) 00059| GCAP (Local0) 00060| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00061| } 00062| 00063| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 174 Line | AML source ---------------------------------------------------------------------------------------------------- 00171| { 00172| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00173| GCAP (Local0) 00174| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00175| } 00176| 00177| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 244 Line | AML source ---------------------------------------------------------------------------------------------------- 00241| { 00242| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00243| GCAP (Local0) 00244| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00245| } 00246| 00247| Method (_OSC, 4, NotSerialized) ==================================================================================================== FAILED [HIGH] AMLAssemblerError1104: Test 2, Assembler error in line 290 Line | AML source ---------------------------------------------------------------------------------------------------- 00287| { 00288| Store (\_PR.CPU0.CPDC (Arg0), Local0) 00289| GCAP (Local0) 00290| Return (Local0) | ^ | warning level 0 1104: Reserved method should not return a value (_PDC) 00291| } 00292| 00293| Method (_OSC, 4, NotSerialized) ==================================================================================================== Table SSDT (1) reassembly: Found 0 errors, 4 warnings. PASSED: Test 2, SSDT (2) reassembly, Found 0 errors, 0 warnings. PASSED: Test 2, SSDT (3) reassembly, Found 0 errors, 0 warnings. ==================================================================================================== 3 passed, 10 failed, 0 warnings, 0 aborted, 0 skipped, 0 info only. ==================================================================================================== Critical failures: 1 method test, at 1 log line: 1449: Detected error 'Package limit' when evaluating '\_SB_.PCI0.GFX0.DD02._BCM'. High failures: 11 klog test, at 1 log line: 121: HIGH Kernel message: [ 3.512783] ACPI Error: Method parse/execution failed [\_SB_.PCI0.GFX0._DOD] (Node f7425858), AE_AML_PACKAGE_LIMIT (20110623/psparse-536) syntaxcheck test, at 1 log line: 1668: Assembler error in line 2261 syntaxcheck test, at 1 log line: 1687: Assembler error in line 2268 syntaxcheck test, at 1 log line: 1703: Assembler error in line 8885 syntaxcheck test, at 1 log line: 1716: Assembler error in line 9195 syntaxcheck test, at 1 log line: 1729: Assembler error in line 9242 syntaxcheck test, at 1 log line: 1742: Assembler error in line 18682 syntaxcheck test, at 1 log line: 1766: Assembler error in line 60 syntaxcheck test, at 1 log line: 1779: Assembler error in line 174 syntaxcheck test, at 1 log line: 1792: Assembler error in line 244 syntaxcheck test, at 1 log line: 1805: Assembler error in line 290 Medium failures: 9 mtrr test, at 1 log line: 76: Memory range 0xc0000000 to 0xdfffffff (PCI Bus 0000:00) has incorrect attribute Write-Combining. mtrr test, at 1 log line: 78: Memory range 0xfee01000 to 0xffffffff (PCI Bus 0000:00) has incorrect attribute Write-Protect. msr test, at 1 log line: 165: MSR SYSENTER_ESP (0x175) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0xffffffffffffffff). msr test, at 1 log line: 173: MSR MISC_ENABLE (0x1a0) has 1 inconsistent values across 2 CPUs for (shift: 0 mask: 0x400c51889). wmi test, at 1 log line: 528: GUID 2B814318-4BE8-4707-9D84-A190A859B5D0 is unknown to the kernel, a driver may need to be implemented for this GUID. method test, at 1 log line: 1002: \_SB_.PCI0.LPCB.SIO_.COM1._DIS returned values, but was expected to return nothing. method test, at 1 log line: 1011: \_SB_.PCI0.LPCB.SIO_.LPT0._DIS returned values, but was expected to return nothing. method test, at 1 log line: 1443: Method _BCL should return a package of more than 2 integers, got just 2. acpitables test, at 1 log line: 1643: FADT 32 bit FIRMWARE_CONTROL is non-zero, and X_FIRMWARE_CONTROL is also non-zero. Se

    Read the article

  • New set up DHCP Server on Server 2008 R2 won't work, Event-ID 1046

    - by Ian
    I just set up a 2008 R2 as DC, and DNS. Both worked fine, DNS works fine forward and reverse lookup. Now I wanted to install DHCP. As soon as the installation of the role is finished, I get this Event-ID Error 1046: Link When I first set it up there was also a Event-ID 1059 Error: Link The dhcp server is authorized. I don't know what else I should do. Getting crazy here, hope you guys can help me.

    Read the article

  • Syslog - capturing event logs from Win2k boxes

    - by molecule
    Hi all, I asked this question in SuperUser without much luck and so I am posting it here to see if anyone can assist. We have a central syslog server and we want it to capture event log events from Windows hosts. We are specifically interested in logging service start/stop events. We installed "Eventlog to Syslog" on these windows hosts and all works well with XP hosts (Events come from Service Control Manager). However, we are having issues with Win2k hosts. For some reason, service start/stop events do not get logged in the Event Log for Win2k hosts. I got another friend from another company to test on a Win2k host and he does get start/stop events on them. I have searched around for local audit policies i need to enable but with not much luck. Anyone have any ideas? Thanks in advance.

    Read the article

  • Several "SideBySide" errors in the event viewer (Windows XP SP3)

    - by Wesley
    Hi all, For some reason, my netbook continuously comes up with SideBySide errors in the event viewer under Computer Management. Is there some way to get rid of these errors? My netbook occasionally BSODs and looking back into the event viewer after, at least 8 SideBySide errors were logged prior to BSOD. Please help! Thanks in advance. Netbook is a Samsung N120 with upgraded RAM to 2 GB. EDIT: So, SideBySide errors have been resolved and apparently the BSOD isn't related. But I remember specifically, that last time I had a BSOD, it was due to an "unknown hard error." What causes that?

    Read the article

  • Access Log Files

    - by Matt Watson
    Some of the simplest things in life make all the difference. For a software developer who is trying to solve an application problem, being able to access log files, windows event viewer, and other details is priceless. But ironically enough, most developers aren't even given access to them. Developers have to escalate the issue to their manager or a system admin to retrieve the needed information. Some companies create workarounds to solve the problem or use third party solutions.Home grown solution to access log filesSome companies roll their own solution to try and solve the problem. These solutions can be great but are not always real time, and don't account for the windows event viewer, config files, server health, and other information that is needed to fix bugs.VPN or FTP access to log file foldersCreate programs to collect log files and move them to a centralized serverModify code to write log files to a centralized placeExpensive solution to access log filesSome companies buy expensive solutions like Splunk or other log management tools. But in a lot of cases that is overkill when all the developers need is the ability to just look at log files, not do analytics on them.There has to be a better solution to access log filesStackify recently came up with a perfect solution to the problem. Their software gives developers remote visibility to all the production servers without allowing them to remote desktop in to the machines. They can get real time access to log files, windows event viewer, config files, and other things that developers need. This allows the entire development team to be more involved in the process of solving application defects.Check out their product to learn morehttp://www.Stackify.com

    Read the article

  • Are Promises/A a good event design pattern to implement even in synchronous languages like PHP?

    - by Xeoncross
    I have always kept an eye out for event systems when writing code in scripting languages. Web applications have a history of allowing the user to add plugins and modules whenever needed. In most PHP systems you have a global/singleton event object which all interested parties tie into and wait to be alerted to changes. Event::on('event_name', $callback); Recently more patterns like the observer have been used for things like jQuery. $(el).on('event', callback); Even PHP now has built in classes for it. class Blog extends SplSubject { public function save() { $this->notify(); } } Anyway, the Promises/A proposal has caught my eye. It is designed for asynchronous systems, but I'm wondering if it is also a good design to implement now that even synchronous languages like PHP are changing. Combining Dependency Injection with Promises/A seems it might be the best combination for handling events currently.

    Read the article

  • How to pass event to method?

    - by tomaszs
    I would like to create a method that takes as a argument an event an adds eventHandler to it to handle it properly. Like this: I have 2 events: public event EventHandler Click; public event EventHandler Click2; Now i would like to pass particular event to my method like this (pseudocode): public AttachToHandleEvent(EventHandler MyEvent) { MyEvent += Item_Click; } private void Item_Click(object sender, EventArgs e) { MessageBox.Show("lalala"); } ToolStripMenuItem tool = new ToolStripMenuItem(); AttachToHandleEvent(tool.Click); Is it possible or do I not understand it good? Edit: I've noticed with help of you that this code worked fine, and returned to my project and noticed that when I pass event declared in my class it works, but when I pass event from other class id still does not work. Updated above example to reflect this issue. What I get is this error: The event 'System.Windows.Forms.ToolStripItem.Click' can only appear on the left hand side of += or -=

    Read the article

  • Event Tracing for Windows GUI

    - by Ian Boyd
    i want to view tracing events from the Event Tracing for Windows system. As far as i can tell the only client program that exists for connecting to providers is a command line tool that comes with the Microsoft Windows Device Driver Development Kit (DDK), e.g.: tracelog -start "NT Kernel Logger" -f krnl.etl -dpcisr -nodisk -nonet -b 1024 -min 4 -max 16 -ft 10 –UsePerfCounter ... tracelog –stop It then requires a separate command line tool to convert the generated log file into something usable, e.g.: trcerpt krnl.etl -report isrdpc.xml Has nobody come up with a Windows program (ala Performance Monitor, Process Monitor, Event Viewer) that lets me start tracing by pushing a "Go" button, let me see events, and i can stop it with a "Stop" button? Is there GUI for Event Tracing for Windows?

    Read the article

  • Looking for event management application

    - by taudep
    Hello, I'm looking for a web-based event management application for managing events (or activities) on certain days that I setup. And then I want people to be able to sign up for them. I'm looking for something that can then be embedded in my website, similar to a Google Calendar. Then for a given event's day, I can click on it, see who's attending. Ideally, I wouldn't have to invite people to the event, but they can just sign up for it. I'm not looking to use something like Evite. This application is going to be used to manage a schedule of bike races, and who from my club will sign up for them. Thanks for any suggestions.

    Read the article

  • access_log item w/out IP. Starts with "::1 - - [<date>]"

    - by Meltemi
    Looking at our Apache log I see normal requests like: 174.133.xxx.xxx - - [20/May/2010:17:36:44 -0700] "GET /index.html HTTP/1.1" 200 2004 but every so often i get a cluster of these w/out an IP address. ::1 - - [20/May/2010:18:47:21 -0700] "OPTIONS * HTTP/1.0" 200 - ::1 - - [20/May/2010:18:47:22 -0700] "OPTIONS * HTTP/1.0" 200 - ::1 - - [20/May/2010:18:47:23 -0700] "OPTIONS * HTTP/1.0" 200 - what do they mean and curious what causes them?

    Read the article

  • Svn log - svn: '.' is not a working copy

    - by fampinheiro
    I'm getting "svn: '.' is not a working copy" when i use the svn log command. I know that i need a working copy for the log command to work but can this be done directly on a repository? My goal is to display the information (change history) of a repository. I think updating the working copy whenever i need the log information is not a good solution. Is there an alternative solution to this or updating a working copy every time i need to log is the only way to go? Thanks in advance.

    Read the article

  • Glassfish v3 Domain Output Log is not ending after the netbeans debug is stopped

    - by Nassign
    I would like to know if anybody is experiencing the problem on endless if log that is too long when Netbeans Debugging session is stopped? We use java logging in our web application but if I stop the debug, suddenly in the Output Glassfish v3 Domain window, there are a lot of log that is being dump. The log would last so long, that I need to click the Stop the Server because if I don't the Netbeans logger would consume too much memory that makes it too slugish later. I am not sure how long until the log stop but it last for minutes. Any ideas here?

    Read the article

  • How to log python exception ?

    - by Maxim Veksler
    Hi, Coming from java, being familiar with logback I used to do try { ... catch (Exception e) { log("Error at X", e); } I would like the same functionality of being able to log the exception and the stacktrace into a file. How would you recommend me implementing this? Currently using boto logging infrastructre, boto.log.info(...) I've looked at some options and found out I can access the actual exception details using this code: import sys try: 1/0 except: exc_type, exc_value, exc_traceback = sys.exc_info() traceback.print_exception(exc_type, exc_value, exc_traceback) I would like to somehow get the string print_exception() throws to stdout so that I can log it. Thank you, Maxim.

    Read the article

  • Alter the cruisecontrol log with XSLTLogPublisher

    - by daramarak
    We build our project from CruiseControl. We have a ant script running some exec commands, and the output of this is placed in the CDATA part of that message, and its priority is set to "info". Now I have created an XSL that modifies this priority depending on the CDATA output, so it creates a new logfile that I want CruiseControl to use. I tried to do this by using XSLTLogPublisher tag like this <xsltlogpublisher directory="${log.dir}" outfile="${logname}" xslfile="${transform}" /> But it doesn't seem to work. No error is logged from cruisecontrol no changes are done in the log file, might it be that cruisecontrol have problems transforming its own log, or are the publishers invoked after the actual log is published as a web page? Can anyone provide some sort of solution to my problem?

    Read the article

  • Export Failed Element Log(s) after deliver?

    - by cogmios
    When a deliver has been performed I can rightlick an entry in the GUI version/element log and it displays me a popup with the element log. Quite handy. I now have a delivery with about 25 failed ones and a couple of hundred OK's. Sadly I can not sort on the column "status" so I have to make screenshots wherever I find a [!] to sit together with the specific team to find out if it is really ok to not deliver those. It would however be handy to have this list of element logs from a deliver so that I do not have to make screenshots or copy the contents of the popup box one by one but just have a list of the failed ones with the element log. Is there a way to export the element logs from a deliver (so the the ones that show up when you rightclick and choose "Display Element Log") and/or only the ones that gave failures?

    Read the article

  • Writing exceptions in multihreaded windows service to event log

    - by Ziplin
    I have a multithreaded windows service that will unpredictably stop running once every 24 hours or so. I am writing to the event log and that's going through just fine, but whenever the service crashes there are no messages in the event log (even that the service stopped, despite having AutoLog=true). Is there a way to have uncaught exceptions written straight to the log, even if they aren't in the original thread?

    Read the article

  • Log Shipped but Won't Update

    - by MooCow
    I'm currently taking the MS SQL 2K5 Admin course at a local college and ran into a problem with the Log Shipping part. My setup is the following: Windows 7 x64 SQL 2005 SP3 2 SQL server instances on the same machine Log Shipping settings: Performed full then log back up of Primary Manually restore on Secondary in STANDBY MODE Insert a new record into the table Set up Log Shipping on Primary using SQL Authenication login to connect to the Secondary Set up timers and copy destination on Secondary Monitoring instance not being used I set up a shared folder for WORKGROUP so both instances on the machine can read & write to it. I can see transaction logs generated and copied as defined by the Transaction Shipping wizard. However, the specified table on the Secondary instance is not updating.

    Read the article

  • Chrome Extension - Console Log not firing

    - by coffeemonitor
    I'm starting to learn to make my own Chrome Extensions, and starting small. At the moment, I'm switching from using the alert() function to console.log() for a cleaner development environment. For some reason, console.log() is not displaying in my chrome console logs. However, the alert() function is working just fine. Can someone review my code below and perhaps tell me why console.log() isn't firing as expected? manifest.json { "manifest_version": 2, "name": "Sandbox", "version": "0.2", "description": "My Chrome Extension Playground", "icons": { "16": "imgs/16x16.png", "24": "imgs/24x24.png", "32": "imgs/32x32.png", "48": "imgs/48x48.png" }, "background": { "scripts": ["js/background.js"] }, "browser_action": { "default_title": "My Fun Sandbox Environment", "default_icon": "imgs/16x16.png" }, "permissions": [ "background", "storage", "tabs", "http://*/*", "https://*/*" ] } js/background.js function click(e) { alert("this alert certainly shows"); console.log("But this does not"); } // Fire a function, when icon is clicked chrome.browserAction.onClicked.addListener(click); As you can see, I kept it very simple. Just the manifest.json and a background.js file with an event listener, if the icon in the toolbar is clicked. As I mentioned, the alert() is popping up nicely, while the console.log() appears to be ignored.

    Read the article

  • big size of database-log SQL-Server 2008

    - by t.kehl
    I have a database which is running under Microsoft SQL Server 2008. Now, I have seen, that the log of the database (ldf-file) is growing to big size. The database-file (mdf) has a size of 630MB and the log-file has a size of 12GB. I ask me now, what the reason for this can be. Is there a tool which let me seeing into the log where I can see, what is the reason for this big size? What can I do to prevent that the log is growing to this big size?

    Read the article

< Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >