Search Results

Search found 680 results on 28 pages for 'kyle burton'.

Page 10/28 | < Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >

  • Public folder not visible from front end Exchange 2003 Server

    - by Kyle Brandt
    I have a public folder that does not receive emails when the emails are sent via the Front-End Exchange Servers. When I go into the System Manager on the Front-End I don't see this particular public folder listed under the Public Folders. However, I do see it listed from the Front-End server. I see the emails that are not making it to the public folder listed in the local delivery queue on the front end server and they are in a retry state. Does anyone know how I might troubleshoot this?

    Read the article

  • Wireless to Wireless Transfer Slow on a Linksys WRT54GL

    - by Kyle Brandt
    The Situation: When I try to transfer a file from one computer to another that are both connected via wireless on a WRT54GL (in a office) with dd-wrt firmware I often get bad speeds. In generally they average around 100 kilobytes a second. Either computer can download via wireless from the Internet at at about 2 megabytes a second. The speed is slow with the transfer of one large file. There are about 20 other wireless networks that the computers can see, so there is a lot of noise, but I don't have the equipment to really monitor the frequencies well. But that still seems pretty slow. I thought maybe it was the transmit on each card, but even when they are 5 feet away with a line of sight I still get these speeds. According to Linux both cards are operating at 54g. My Questions: Is this normal for this sort of consumer level wireless equipment? Anything I can do to improve it? why is wireless to wireless transfer slow when everything else isn't? Whats steps might I take to figure out what is happening? For example, are lots of packets not making to the access point requiring retransmissions? Above all, I want to find out what the problem actually is. This may seem odd, but at this point I am more interested in understanding what the problem is than fixing it. What I have tried: I have tried messing with lots of settings. Different channels, xmit power, G-Only, none of which has made anything any better. I've also tried upgrading to newer dd-wrt firmware version and doing a reset to wipe out the settings.

    Read the article

  • Why LLBLGen Pro v3.0 is better than the regular designer for EF v4.0

    As a comment to my blogpost about the 12 minute long video of LLBLGen Pro with Entity Framework v4.0, Burton Roberts asks: Could you list the advantages of using llblgen pro 3 with Entity Framework versus using EF alone? Of course! Now, I know these posts are often classified as 'marketing' but so be it. Why is the LLBLGen Pro v3.0 designer better for Entity Framework v4.0 than the regular Entity Framework designer? Below I'll give an (incomplete) list of features you have at your disposal...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Pasting extended ACL contents into telnet session to Cisco Router SIM

    - by Kyle Brandt
    I have a telnet session to a dynamips router sim. When I try to paste the contents of an actually working ACL retrieved from 'show run' into the access list, only part of gets pasted. The session is something like: enable conf t ip access-list extended Internet <PASTE of Rules> It stops right in the middle of a line: permit tcp any host 123.123.123.123 gt 1 ! should be gt 1023 Anyone know what is happening? The source is an extended access list.

    Read the article

  • *nix shell with IOS style completion?

    - by Kyle Brandt
    Is there a Linux shell that will let you type less than full commands as you can with Cisco IOS, at least for the first command (and not its arguments)? I haven't really thought enough if this is actually a good thing, but might be fun to play with :-)

    Read the article

  • lighttpd config and rewriting/disabling attempts to access favicon.ico

    - by Kyle
    I've got lighttpd and apache working together on an app I'm building. lighty is serving out static content. However, each time a static asset is requested, I see a not found: favicon.ico message in the logs. I have added the following url rewrite: url.rewrite-once = ( "^/favicon.ico$" => "/assets/images/favicon.png" ) But to no avail; still getting the message. Any ideas?

    Read the article

  • Datacenter Colocation Phone

    - by Kyle Brandt
    In my cage I don't get good enough phone reception. An phone that goes over the network also doesn't seem ideal for when I am working on the network. Do you people have traditional phones delivered to their cage? I'm wonder what my options are.

    Read the article

  • Can't Mount Databases in the Recovery Storage Group in Exchange 2003

    - by Kyle Brandt
    After restoring some mail stores, mounting them in the recovery storage group errors out. So far a repair with eseutil (which the log says was successful) and a server reboot has been tried. A defrag is currently running on the mail store I need to go through this again to post the exact error codes, so I will be updating this question. But I thought someone who does this a lot might have a "More times than not..." answer in the meantime.

    Read the article

  • TTL for PTR records on Windows 2003 Server DNS

    - by Kyle Brandt
    When I look at the TTL (Time to Live) for PTR records (Reverse Lookup Zone) on one of our Windows 2003 DNS servers I see some are at 15 minutes, others are at 20. They have "Delete this record when it becomes stale" checked. These PTR records are for workstations that get IPs from Windows DHCP, so I think that creates the PTR records dynamically? How is TTL for these records set?

    Read the article

  • Sendmail Tuning For Batch Mail Jobs

    - by Kyle Brandt
    I have a webservers that send out emails to a sendmail relay server as a batch job. The emails need to be accepted by the relay sendmail server as fast as possible, however, they do not need to go out (be relayed) very quickly. I am seeing a couple timeouts once and a while from the webserver trying to connect to the relay server. The load currently is about 30 emails a second for a couple minutes. There are quite a few tuning options for sendmail in the sendmail tuning guide. What I am focusing on now is the Delivery Mode: Delivery Mode There are a number of delivery modes that sendmail can operate in, set by the DeliveryMode ( d) configuration option. These modes specify how quickly mail will be delivered. Legal modes are: i deliver interactively (synchronously) b deliver in background (asynchronously) q queue only (don't deliver) d defer delivery attempts (don't deliver) There are tradeoffs. Mode i gives the sender the quickest feedback, but may slow down some mailers and is hardly ever necessary. Mode b delivers promptly but can cause large numbers of processes if you have a mailer that takes a long time to deliver a message. Mode q minimizes the load on your machine, but means that delivery may be delayed for up to the queue interval. Mode d is identical to mode q except that it also prevents lookups in maps including the -D flag from working during the initial queue phase; it is intended for ``dial on demand'' sites where DNS lookups might cost real money. Some simple error messages (e.g., host unknown during the SMTP protocol) will be delayed using this mode. Mode b is the usual default. If you run in mode q (queue only), d (defer), or b (deliver in background) sendmail will not expand aliases and follow .forward files upon initial receipt of the mail. This speeds up the response to RCPT commands. Mode i should not be used by the SMTP server. I currently have the CentOS default modes: Sendmail.cf: DeliveryMode=background Submit.cf: DeliveryMode=i Is sendmail.cf/mc for outgoing email from relay (to the intertubes) and sumbit.cf/mc for incoming eamil (from my webservers). Would it make sense to change the outgoing delivery mode to queue? If I did, what would the outbound email flow behave like? If this is the right thing to do, can anyone show me example mc configurations for this change? If it isn't, what recommendations are there for these constraints?

    Read the article

  • How to configure remote access to multiple subnets behind a SonicWALL NSA 2400

    - by Kyle Noland
    I have a client that uses a SonicWALL NSA 2400 as their firewall. I need to setup a second LAN subnet for a handful of PC. Management has decided that there should be a second subnet even though intend to allow access across the two subnets - I know... I'm having trouble getting communication across the 2 subnets. I can ping each gateway, but I cannot ping or seem to route traffic fron subnet A to subnet B. Here is my current setup: X0 Interface: LAN zone with IP addres 192.168.1.1 X1 Interface: WAN zone with WAN IP address X2 Interface: LAN zone with IP address 192.168.75.1 I have configured ARP and routes for the secondar subnet (X2) according to this SonicWALL KB article: http://www.sonicwall.com/downloads/supporting_multiple_firewalled_subnets_on_sonicos_enhanced.pdf using "Example 1". At this point I don't minding if I have to throw the SonicWALL GVC software VPN client into the mix to make it work. It feel like I have an Access Rule issue, but for testing I made LAN LAN, WAN LAN and VPN LAN rules wide open with the same results.

    Read the article

  • Remove Audio stream from XVID files

    - by Kyle Brandt
    I have a bunch of Xvid files that each have an audio stream that I do not want. How can I strip the audio track I don't want using the Linux command line? I don't need the whole script (loop), just what command I would use to process each avi file individually (unless the cmd itself has batch modification built into it). I don't believe the file is in an mkv container, as mkvinfo doesn't find anything. Here is part of mplayer's output (thanks ~quack): [aviheader] Video stream found, -vid 0 ID_AUDIO_ID=1 [aviheader] Audio stream found, -aid 1 ID_AUDIO_ID=2 [aviheader] Audio stream found, -aid 2 VIDEO: [XVID] 512x384 12bpp 25.000 fps 1013.4 kbps (123.7 kbyte/s)

    Read the article

  • Show multiple calendars in overlay view by default

    - by Kyle Strand
    In MS Outlook 2007/2010, it's possible to show multiple calendars overlayed on each other (a la Google Calendar; see http://office.microsoft.com/en-us/help/view-calendars-side-by-side-or-overlaid-HA001230157.aspx#BM4). However, it appears that in order to do this, you must first open the calendars side-by-side and then press the little left-arrow button to "combine" them into an overlaid view. Is there a way to make "overlaid" the default view for multiple calendars (again, a la Google Calendar)?

    Read the article

  • Windows 2008 R2 Servers Sending Arp Requests for IPs outside Subnet

    - by Kyle Brandt
    By running a packet capture on my my routers I see some of my servers sending ARP requests for IPs that exist outside of its network. For example if my network is: Network: 8.8.8.0/24 Gateway: 8.8.8.1 (MAC: 00:21:9b:aa:aa:aa) Example Server: 8.8.8.20 (MAC: 00:21:9b:bb:bb:bb) By running a capture on the interface that has 8.8.8.1 I see requests like: Sender Mac: 00:21:9b:bb:bb:bb Sender IP: 8.8.8.20 Target MAC: 00:21:9b:aa:aa:aa Target IP: 69.63.181.58 Anyone seen this behavior before? My understanding of ARP is that requests should only go out for IPs within the subnet... Am I confused in my understanding of ARP? If I am not confused, anyone seen this behavior? Also, these seem to happen in bursts and it doesn't happen when I do something like ping an IP outside of the network. Update: In response to Ian's questions. I am not running anything like Hyper-V. I have multiple interfaces but only one is active (Using BACS failover teaming). The subnet mask is 255.255.255.0 (Even if it were something different it wouldn't explain an IP like 69.63.181.58). When I run MS Network Monitor or wireshark I do not see these ARP requests. What happens is that on the router capturing I see a burst of about 10 requests for IPs outside of the network from the host machine. On the machine itself using wireshark or NetMon I see a flood of ARP responses for all the machines on the network. However, I don't see any requests in the capture asking for those responses. So it seems like maybe it is maybe refreshing the arp cache but including IPs that outside of the network. Also when it does this NetMon doesn't show the ARP requests?

    Read the article

  • Only One GPU Detected in the Nvidia Quadra NVS 450

    - by Kyle Brandt
    I just built myself an new workstation and now only 2 of 3 monitors are working. I built the nvidia driver by downloading it and installing with ./Nvidia... Before when I ran nvidia-settings I saw two GPUs listed but now I only see one. Xorg Config (Not sure how I ended up with 3 devices in there): # nvidia-settings: X configuration file generated by nvidia-settings # nvidia-settings: version 256.35 (buildmeister@builder101) Wed Jun 16 19:25:39 PDT 2010 Section "ServerLayout" # Removed Option "Xinerama" "1" Identifier "Layout0" Screen 0 "Screen0" 0 0 Screen 1 "Screen1" RightOf "Screen0" InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" Option "Xinerama" "0" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor0" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor1" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" # HorizSync source: edid, VertRefresh source: edid Identifier "Monitor2" VendorName "Unknown" ModelName "DELL E207WFP" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:6:0:0" EndSection Section "Device" Identifier "Device1" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:5:0:0" EndSection Section "Device" Identifier "Device2" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "Quadro NVS 450" BusID "PCI:3:0:0" EndSection Section "Screen" # Removed Option "TwinView" "0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+0" # Removed Option "metamodes" "DFP-0: nvidia-auto-select +0+275, DFP-3: nvidia-auto-select +1680+0" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "DFP-3" Option "metamodes" "DFP-0: nvidia-auto-select +0+0, DFP-3: nvidia-auto-select +1680+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" # Removed Option "metamodes" "DFP-3: nvidia-auto-select +0+0" Identifier "Screen1" Device "Device1" Monitor "Monitor1" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" Identifier "Screen2" Device "Device2" Monitor "Monitor2" DefaultDepth 24 Option "TwinView" "0" Option "metamodes" "nvidia-auto-select +0+0" SubSection "Display" Depth 24 EndSubSection EndSection lscpi: 00:00.0 Host bridge: Intel Corporation 5520/5500/X58 I/O Hub to ESI Port (rev 13) 00:01.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 1 (rev 13) 00:02.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 2 (rev 13) 00:03.0 PCI bridge: Intel Corporation 5520/5500/X58 I/O Hub PCI Express Root Port 3 (rev 13) 00:10.0 PIC: Intel Corporation 5520/5500/X58 Physical and Link Layer Registers Port 0 (rev 13) 00:10.1 PIC: Intel Corporation 5520/5500/X58 Routing and Protocol Layer Registers Port 0 (rev 13) 00:11.0 PIC: Intel Corporation 5520/5500 Physical and Link Layer Registers Port 1 (rev 13) 00:11.1 PIC: Intel Corporation 5520/5500 Routing & Protocol Layer Register Port 1 (rev 13) 00:13.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub I/OxAPIC Interrupt Controller (rev 13) 00:14.0 PIC: Intel Corporation 5520/5500/X58 I/O Hub System Management Registers (rev 13) 00:14.1 PIC: Intel Corporation 5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers (rev 13) 00:14.2 PIC: Intel Corporation 5520/5500/X58 I/O Hub Control Status and RAS Registers (rev 13) 00:15.0 PIC: Intel Corporation 5520/5500/X58 Trusted Execution Technology Registers (rev 13) 00:1a.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #4 00:1a.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #5 00:1a.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #6 00:1a.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #2 00:1b.0 Audio device: Intel Corporation 82801JI (ICH10 Family) HD Audio Controller 00:1c.0 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 1 00:1c.1 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Port 2 00:1c.3 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 4 00:1c.4 PCI bridge: Intel Corporation 82801JI (ICH10 Family) PCI Express Root Port 5 00:1d.0 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #1 00:1d.1 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #2 00:1d.2 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB UHCI Controller #3 00:1d.7 USB Controller: Intel Corporation 82801JI (ICH10 Family) USB2 EHCI Controller #1 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev 90) 00:1f.0 ISA bridge: Intel Corporation 82801JIR (ICH10R) LPC Interface Controller 00:1f.2 IDE interface: Intel Corporation 82801JI (ICH10 Family) 4 port SATA IDE Controller #1 00:1f.3 SMBus: Intel Corporation 82801JI (ICH10 Family) SMBus Controller 00:1f.5 IDE interface: Intel Corporation 82801JI (ICH10 Family) 2 port SATA IDE Controller #2 01:00.0 IDE interface: Device 1b4b:91a3 (rev 11) 02:00.0 USB Controller: NEC Corporation Device 0194 (rev 03) 03:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:00.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 04:02.0 PCI bridge: nVidia Corporation PCI express bridge for Quadro Plex S4 / Tesla S870 / Tesla S1070 (rev a3) 05:00.0 3D controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 06:00.0 VGA compatible controller: nVidia Corporation G98 [Quadro NVS 450] (rev a1) 08:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 08:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 02) 09:00.0 SATA controller: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 09:00.1 IDE interface: JMicron Technology Corp. JMB362/JMB363 Serial ATA Controller (rev 03) 0a:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) 0b:06.0 FireWire (IEEE 1394): Texas Instruments TSB43AB23 IEEE-1394a-2000 Controller (PHY/Link)

    Read the article

  • Ninety-Fifth Percentile Calculation for Bandwidth

    - by Kyle Brandt
    I am trying to calculate the bandwidth of my current internet connection. I am pulling the current input and output transfer rate via snmp. If the argument to the following function is a sorted ascending list of the the some of each input and output sample, is this the right way to calculate 95th percentile? sub ninetyFifth { #Expects Sorted Data my $ninetyFifthLine = (@_ * .95) - 1; return $_[$ninetyFifthLine]; }

    Read the article

  • How can I create profiles for the windows that are open on my Mac?

    - by Kyle Hayes
    As a semi-dual monitor user on my MacBook, I run into a particular issue that drives me nuts. The scenario is at work I run my MacBook Pro's display as the secondary monitor to a dual-monitor setup. I primarily use the secondary view for my social network windows (Adium, Tweetie, Gabbble, and IRC). I position exactly as I want them to see all at the same time. However, when I disconnect my MBP to go home and reconnect to my other monitor at home, all the applications were shifted onto the main screen (since that is where they went when I disconnected the monitor before I left). With this, I have to go through the whole process again to move and position them on the secondary screen again. Is there a utility or application that will allow me to create screen/window profiles that will basically memorize the current position of all the windows and persist it to be re-instantiated later?

    Read the article

  • Cisco Switching Module and HSRP interface Tracking

    - by Kyle Brandt
    When using 4 port switching module where each port is configured to switchport access vlan ##, for HRSP should I track the vlan interface or the FastEthernet interface? interface FastEthernet0/0/0 switchport access vlan 10 interface Vlan10 ip address 12.12.12.1 255.255.255.0 int FastEthernet0/1 ip address 192.168.1.2 255.255.255.0 standyby ip 192.168.128.1 standby track ?? ! FastEthernet 0/0/0 or Vlan 10?

    Read the article

  • Configuring Redhat / CentOS 5 SSH to authenticate to IPA server with public keys

    - by Kyle Flavin
    I'm trying to configure some Red Hat/CentOS servers to use an ipa-server on CentOS 6 for SSH authentication with public keys. I'm storing the public keys on the IPA server, which works great on Centos6 using "AuthorizedKeysCommand /usr/bin/sss_ssh_authorizedkeys" in /etc/ssh/sshd_config. However, on RH 5.10, neither the "AuthorizedKeysCommand" directive or the "/usr/bin/sss_ssh_authorizedkeys" command exist to pull the public key from the directory. Is there a different way to make this work? Googling this mostly returns instructions for setting it up on 6.

    Read the article

  • mod_vhost_alias question.

    - by Kyle
    Is it possible that mod_vhost_alias can read several directories (For example, each users) to find the sites? Like in a hosting setup where different users can create the directories in their home directory?

    Read the article

  • Attaching 3.5" desktop drive to MacBook SATA

    - by Kyle Cronin
    I have a mid-2007 MacBook that, according to the Apple Store, has suffered some liquid damage and requires a new logic board to operate correctly, a ~$750 repair I've been told (would normally be around ~$300 were it not for the "liquid damage"). The unit itself works fine - the only problem I've been having is that the system does not recognize the battery and will not charge it. Curiously, the system can still be powered by the battery and even recognizes when the power cord is detached by diming the backlight, but I digress. Now that this laptop will likely become a desktop, I'm wondering if it might be possible to attach a desktop drive. I recently purchased a 2TB SATA drive and I'm wondering if it's possible to somehow attach it where the current internal drive connects. Obviously the drive itself will not fit inside the device, but as the unit will spend the rest of its days on my desk, that's not really much of an issue. My main questions are: Is this possible? If so, how would I connect the drive? Would a SATA extender cable work? Is the SATA port on my MacBook capable of powering a desktop drive? Or should I just get a SATA male-to-female cable and see if I can power the drive through other means (a cheap power supply, for example) The disk I'm referring to is the Hitachi Deskstar HD32000. Though I couldn't find that exact model on Hitachi's support site, these are the power requirements for a similar drive, the 7K2000 (2TB, 7200RPM, SATA II): Power Requirement +5 VDC (+/-5%) +12 VDC (+/-10%) Startup current (A, max.) 1.2 (+5V), 2.0 (+12V) Idle (W) 7.5 From what I've read, 2.5" drives require 5V, meaning that my MacBook obviously is capable of producing it. The specs seem to suggest that this drive seems capable of accepting it instead of the typical 12V - is this an accurate interpretation of the power requirements? Or does it need both 12V and 5V?

    Read the article

< Previous Page | 6 7 8 9 10 11 12 13 14 15 16 17  | Next Page >