  • WHS - Windows Update Failure

    - by Kyle B.
    Clicking "Update Now..." inside my EX470 control panel for Windows Update produces the following error message: "Windows Home Server updates installation can not complete. Please try again later. If the problem persists, please restart the server." I have rebooted the server numerous times, and I have also used remote desktop to connect to the machine to perform the update this way, however the browser is unable to pull up http://windowsupdate.microsoft.com. This is very strange behavior because I am able to access all other sites (gmail.com, serverfault.com, etc). Would it be possible for someone to explain to me how I can check to see what is blocking the connection of this device, which apparently has a valid internet connection, to the Microsoft Windows Update site? note #1 Using the shortcut: %SystemRoot%\system32\wupdmgr.exe does not work either. It says "Connecting to 65.55.200.155..." but nothing ever happens. This is strange because all other sites seem fine. Also, I can connect to windowsupdate.microsoft.com on my local desktop so I know this is running as well

    Read the article

  • Running Job and Paused Job Writing to the same File

    - by Kyle Brandt
    So I ran tcpdump twice overnight by accident, both outputting to the same file. However, I ran them as jobs and one of them has been paused the whole time. Anyone have a recommendations on how to keep the file? So far I have thought of: kill -9 the paused job Pause the running job, copy the file, and then stop both. Two sounds like the safest option, anyone have a better idea other than not doing this in the first place ;-)

    Read the article

  • Finding out why Dell Controler is Degraded

    - by Kyle Brandt
    I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState: [root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up. A walk of the entire storage management tree for on of them: StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

    Read the article

  • My -tpl file won't update!

    - by Kyle Sevenoaks
    Hi, I am running the site at www.euroworker.no, it's a linux server and the site has a backend editor. It's a smarty/php site, and when I try to update a few of the .tpl's (two or three) they don't update. I have tried uploading through FTP and that doesn't work either. I have no knowledge of how servers work or anything, please help? It runs on the livecart system. Thanks!

    Read the article

  • My -tpl file won't update!

    - by Kyle Sevenoaks
    Hi, I am running the site at www.euroworker.no, it's a linux server and the site has a backend editor. It's a smarty/php site, and when I try to update a few of the .tpl's (two or three) they don't update. I have tried uploading through FTP and that doesn't work either. I have no knowledge of how servers work or anything, please help? It runs on the livecart system. Thanks!

    Read the article

  • tcpdump filter that excludes private ip traffic

    - by Kyle Brandt
    For a generic filter to exclude all traffic in my dump that is between private IP address, I came up with the following: sudo tcpdump -n ' (not ( (src net 172.16.0.0/20 or src net 10.0.0.0/8 or src net 192.168.0.0/16) and (dst net 172.16.0.0/20 or dst net 10.0.0.0/8 or dst net 192.168.0.0/16) ) ) and (not ( (dst net 172.16.0.0/20 or dst net 10.0.0.0/8 or dst net 192.168.0.0/16) and (src net 172.16.0.0/20 or src net 10.0.0.0/8 or src net 192.168.0.0/16) ) )' -w test2.dump Seems pretty excessive, but it also seems to work, is this filter a lot longer than it needs to be and there is better way to express this logic, or is there anything wrong with the filter?

    Read the article

  • Using NTBackup to Backup Exchange 2003 Mail Stores

    - by Kyle Brandt
    I have netbackup backing up my Exchange stores stores to tape, but would like to maybe make the restore process faster. I have plenty of room on the array attached to the mail server, so I was thinking I could use NTBackup to do weekly backups in addition to my tape backups. Has anyone used this with good success?

    Read the article

  • Disable laptop screen

    - by Kyle
    I recently had the display fail on my Dell Inspiron E1505 laptop. I currently have my TV hooked up to the laptop's S-Video out which works fine as long as I'm running in Windows. For the first minute or so when the computer is booting I get no display. I was wondering if there was any way to disable the laptop screen entirely so that the TV display is active from the beginning (not just after Windows loads). I realize there may be a BIOS setting for this, my only problem is I can't see the BIOS settings screen since no display is active at that point so if anyone has any BIOS setting solutions I'd need the exact keystrokes to hit :)

    Read the article

  • PostgreSQL has no service name on CentOS

    - by Kyle MacFarlane
    I installed PostgreSQL in a pretty standard way on CentOS 5.5: rpm -ivh http://yum.pgrpms.org/reporpms/9.0/pgdg-centos-9.0-2.noarch.rpm yum install postgresql90-server postgresql90-contrib chkconfig postgresql-90 on /etc/init.d/postgresql-90 initdb But for some reason I can't use it with the service command because it has no name, .e.g if I do service --status-all I get back the following: master (pid 3095) is running... (pid 3009) is running... rdisc is stopped Or even just /etc/init.d/postgresql-90 status: (pid 3009) is running... So how can I give it a name so that I don't have to type out the whole init script path each time?

    Read the article

  • How can I prevent static when PC is plugged into an amplified speaker system?

    - by Kyle
    I've plugged a computer into an amp, using a 1/8 inch male extension cord, into a female adapter, that adapts into a male microphone 1/4 end. That being said, the amp sits at about half volume all the time because there are other things that play on it. (This issue is not flexible, nor is changing the amp) The problem is that now, even when I mute out the computer, you hear some static in the background. I was wondering some about some solutions (preferably multiple).

    Read the article

  • Linux machine can't find its tape drive

    - by Kyle Hodgson
    I have an older HP NetServer LPr with what is apparently a Symbios SCSI card connecting to a Quantum SuperLoader 3 that is DLT based. From time to time, we seem to lose the connection to the autoloader. It's usually due to flaky power, but not totally sure why; sometimes when this happens the Autoloader's LED's are orange and it needs to be power cycled. The annoying workaround currently is to reboot the machine. As it is our production VPN and DNS server in addition to being our backup server, this is less than optimal. In Debian (Sarge) is there not some command one can type to get the card to notice that it has the autoloader connected again? dcr1:/proc# grep -i symbios /proc/pci SCSI storage controller: LSI Logic / Symbios Logic 53c895 (rev 1). dcr1:/proc# uname -a Linux dcr1 2.4.27-3-686 #1 Tue Dec 5 21:03:54 UTC 2006 i686 GNU/Linux dcr1:/proc# mt status mt: /dev/tape: No such device dcr1:/proc# ls -l /dev/tape lrwxrwxrwx 1 root root 8 2007-02-07 16:01 /dev/tape -> /dev/st0 dcr1:/proc# That mt status command will show the actual st0 status when things are working correctly. The No such device message is usually the second clue that we need to reboot - the first clue is usually that the backups didn't run.

    Read the article

  • How Does Failover Clustering Work in Windows 2008 R2?

    - by Kyle Brandt
    I am trying to learn how the failover clustering features works with Windows 2008 R2 as I am going to be using as part of SQL Server 2012 always on. I have been able to find information on how to set it up, and what it does. However, I am having trouble finding a nice technical document on how it actually works in detail (For example with keepalived there are docs that explain how often are heartbeat packets sent, what they look like etc). I know this is a pretty broad question, but I would like to have a good understanding of mechanisms of this feature.

    Read the article

  • Where are my Vista documents?

    - by Kyle Sevenoaks
    Hi, on my compputer here at work, the motherboard on one machine decided to fry over the weekend, all of my saved work is on the harddrive here, it has Vista Business as it's OS and my documents were in My Documents. I have since moved the HDD over to a new computer and am trying to locate these files, as I can't work without them and it's not a case of doing it again, this is over three months work. There were three user accounts, mine, my bosses and a guest accont. Where are these My Documents? How can I get them? Thanks for any help you can provide :)

    Read the article

  • IIS running but not serving content

    - by Kyle
    I have an internal dev server running Windows 2k8 R2 with the Web and FTP Server roles set up which won't serve any content at all. Trying to connect from another host via telnet yields 'connection failed': c:\>telnet devserver 80 Connecting To devserver...Could not open connection to the host, on port 80: Conn ect failed Using netstat -an | find "80" on the dev server returns no connections on port 80 (a few on 1801, etc) tcpview confirms this, listing no open connections on port 80. The following services related to the Web role are running: World Wide Web Publishing Service Application Host Helper Service Microsoft FTP Service (ftp connections to port 21 are granted) Windows Process Activation Service The default website bindings are: Type Host Name Port IP Address Binding Information http 80 * net.tcp 808:* net.pipe * net.msmq localhost msmq.formatname localhost When setting up a new application under the default site, the test function passes both connection/authorisation only if the 'connect as' user is local admin, otherwise the test errors with 'invalid application path'. At no point is the W3SVC service PID bound to port 80 (it is running and bound to 21 for ftp). There are no W3SVC log directory at c:\inetpub\logs\LogFiles\ (only FTPSVC2), and no HTTPERR directory at c:\windows\system32\ or c:\windows\system32\logfiles\. There do not appear to be any related errors in the event logs. I'd really appreciate any thoughts on be a good place dig into what's (not) going on here!

    Read the article

  • Dynamips and Tap Devices, To and From the same machine

    - by Kyle Brandt
    I am setting up a dynamips/dynagen lab and am wondering if there is any way to get traffic to route out one tap devices, go into the lab, and come back to a tap device on the same machine. I have tried host specific routes as well as removing the route created when I give the tun device an ip via ifconfig. With both of these, traffic always preferes the attached devices and won't go through my lab. Any way to make this work without a separate machine or vm?

    Read the article

  • How to Set Linux Bonding Interface to Gigabit

    - by Kyle Brandt
    I have enabled Linux active backup mode bonding. Each interface is a gigabit interface, but the bond interface seems to end up at 100 Megabit: bonding: bond0: Warning: failed to get speed and duplex from eth1, assumed to be 100Mb/sec and Full. ... bnx2: eth0 NIC Link is Up, 1000 Mbps full duplex, receive & transmit flow control ON ... bonding: bond0: backup interface eth1 is now up ethtool apparently can't provide info on bond: sudo ethtool bond0 Settings for bond0: No data available So does this mean I am operating at 100 or 1000 Megabit (My guess is 1000)? If it is only 100, what options in the ifcfg scripts or the modprobe bonding options do I need to sett to make it 1000?

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here.

    Read the article

  • Cisco QoS Guidence

    - by Kyle Brandt
    I have a 10M connection to the internet that is hooked into a 100M port. I am getting started with QoS, and am hopping for a little guidance on setting it up on a Cisco 3825 router. Right now I am going forward with the idea that I have to implement it on my router, and the provider can't provide QoS for me. How I envision it working is that the QoS will drop or queue packets on my router and that will help prevent a situation where the provider has to start dropping a lot of packets. Right now all I am tasked with is making sure that one of the 3 LANs gets a certain slice (say 3M for Gig Lan1) of the 10M internet connection (But ideally this will be more flexible in the Future). 10M Internet on 100M port on HWIC-4ESW +-----------------------+ | | Gig Lan1 | Cisco 3825 | Lan3 on HWIC-4ESW | | +-----------------------+ Gig Lan2 I need to learn more about QoS, but having a target technology and maybe example configuration will help me wrap my head around the reading I am doing a little more. Which Cisco QoS Technology do you recommend for this particular situation? Have a basic sample config of how this might work? Right now the 10M line is not congested, so this more to have something in place in case it starts to become mildly congested in the future.

    Read the article

  • Server Fault Wiki: How does Subnetting Work?

    - by Kyle Brandt
    How does Subnetting Work, and How do you do it by hand or in your head? Can someone explain both conceptually and with several examples? Server Fault gets lots of subnetting homework questions, so we could use an answer to point them to on Server Fault itself. If I have a network, how do I figure out how to split it up? If I am given a netmask, how do I know what the network Range is for it? Sometimes there is a slash followed by a number, what is that number? Sometimes there is a subnet mask, but also a wildcard mask, they seem like the same thing but they are different? Someone mentioned something about knowing binary for this? Not looking for links to other sites (unless maybe you have one post with a bunch of good ones). I already know how to subnet, I just thought it would be nice if Server Fault had a generic subnetting answer.

    Read the article

  • MDB2, Pear, Mysql error

    - by Kyle Hudson
    ORIGINALLY POSTED ON http://stackoverflow.com/questions/2682332/mdb2-pear-mysql-error however as its a server issue thought i may have more luck here. Hi Guys, I have PEAR, MDB2 and Mysql Driver installed however I keep getting: Fatal error: Call to undefined function: MDB2_Driver_mysql::_isNewLinkSet(). in /home/**/PEAR/MDB2.php on line 1937. The Server is CentOS I am stuck, any help would be appriciated. Thanks :)

    Read the article

  • Is MozyHome Remote Backup known to slow down Windows Explorer?

    - by Kyle Estes
    Windows Explorer on my home machine is uber slow, and I suspect it is Mozy's fault. In the past Mozy has done some goofy stuff like placing file and folder icon overlays in Windows Explorer, which was really bugging me because I thought they were from TortoiseSVN (and I had uninstalled that!). Anyhow, does anyone else have Mozy installed? Is Windows Explorer really slow respond for you, say when you simply double click the hard drive to browse files? I'd also welcome any tips people might have on debugging why Windows Explorer might be slow (shell extensions known to cause problems, etc.).