Search Results

Search found 3231 results on 130 pages for 'oracle10g express'.

Page 104/130 | < Previous Page | 100 101 102 103 104 105 106 107 108 109 110 111  | Next Page >

  • Windows 7 BSOD when changing power plan

    - by dd5
    i have a strange problem. When i want to change the power plan on my laptop from High performance to Balanced, Windows freezes and i get bsod. The power plan settings are all default. Laptop specs: - Intel Core i3 330M/350M - Intel® HM55 Express Chipset - DDR3 1066 MHz SDRAM 8GB - ATI Mobility™ Radeon HD5730 1GB DDR3 VRAM - Intel SSD330 128gb - Windows 7 Home premium I've searched the internets but couldnt find a similar issue. BSOD first started when i installed this SSD and stopped when i've updated the chipset controller driver then started again yesterday when i wanted to change the power settings plan.Minidump file here. Any help with this weird issue appriciated, thanks. Edit: - i've ran Memory diagnostic tool, - Intel SSD diagnostics - and updated the firmware to 3.2.1. Non of these steps worked or shown signs of errors - but still got BSOD when changing power plan settings. After analizing the dump file via osronline.com here a first few lines: CRITICAL_OBJECT_TERMINATION (f4) A process or thread crucial to system operation has unexpectedly exited or been terminated. Several processes and threads are necessary for the operation of the system; when they are terminated (for any reason), the system can no longer function. Arguments: Arg1: 0000000000000003, Process Arg2: fffffa8008661b30, Terminating object Arg3: fffffa8008661e10, Process image file name Arg4: fffff800033de270, Explanatory message (ascii) -- Solution -- Provided by Vinayak: After installing the Intel Rapid storage Technology from MajorGeeks, i didn't experience a BSOD since, thank you :)

    Read the article

  • XenServer 5.5 running WHS.. trying to add local or network printer/scanner/copier

    - by ProstheticHead
    Hi guys. Just wondering if anyone has prior experience in sharing a multifunction printer across a (mostly windows) network? My situation at the minute is complicated.. I DID have the printer attached directly to a Windows Home Server box and was able to scan to a share and print across the network from my other computers. Compatibility problems have forced me to virtualize WHS on XenServer 5.5... This is actually quite useful because I can now run other things on the same box, but the problem is that now WHS doesn't get direct hardware access so it doesn't see a USB attached PSC... Grrrr! So now I have a choice to make. I've read somewhere that I can buy an add in PCI USB controller and somehow set up a passthrough to one VM at a time. To me, this sound complicated but if it's likely to work reliably I'd prefer this method. I've read about another approach, which I'm not sure about either, but I guess sounds plausible. A Network USB server, (NOT a print server) that can somehow make a USB port accessible across a network. My worry here is that it likely needs some kind of 3rd party software to work.. so not ideal. If there are any other methods you can suggest I'd be happy to hear them... I need your help guys. I'm also in the market for a PCI express SATA controller, nothing flashy, just need up to 8 ports, JBOD and 100% compatability.. Any suggestions? Regards Kevin

    Read the article

  • How can I avoid a few seconds of blank video when using -vcodec copy?

    - by arlomedia
    I'm processing user-uploaded videos on a CentOS web server with ffmpeg. I need to convert each video to a standard size and format, then extract a 30-second sample clip from each video. I want to use the "-vcodec copy" flag in the extraction command to avoid encoding a second time. This command works for my initial conversion: ffmpeg -i uploaded.mov -f mp4 -vcodec libx264 -vpre medium -acodec libfaac -r 15 -b 360k -ab 48k -ar 22050 -s 480x320 formatted.mp4 And this sometimes works for the extraction: ffmpeg -i formatted.mp4 -vcodec copy -acodec copy -ss 0 -t 30 formatted_sample.mp4 However, when I run the extraction command on some videos, the extracted sample clip starts with several seconds of blank video. The audio starts right away but the video doesn't start for 3-6 seconds. To demonstrate the problem, I've uploaded two video clips and run the above commands on them. I created the first clip in Final Cut Express and encoded it with Handbrake before uploading to the web server: 1a) uploaded clip 1b) converted with first command 1c) extracted with second command, missing first six seconds By comparison, this second clip comes from Apple's website and does not show the problem: 2a) uploaded clip 2b) converted with first command 2c) extracted with second command, no problem Can anyone see what's different about the two source clips? And if so, is there anything I can do in my conversion command so that when the extraction command runs, the clip is set up to avoid the missing video? By the way, I initially had the problem with ffmpeg 0.6.1 installed from yum, but I upgraded to the latest git version and the problem remains.

    Read the article

  • PC power supply & normal range for voltages reported in BIOS hardware monitor?

    - by Chris W. Rea
    I'm trying to diagnose whether my computer has an ample power supply. Sometimes when I play a video-intensive game, both monitors lose the video signal, even though the computer remains on and sound playing. A theory I have is: the video card isn't getting sufficient power. I can't imagine it's overheating because the machine is well-ventilated and the video card isn't hot to touch when this happens. Anyway, in my PC's BIOS there's a Hardware Monitor page, and among other voltages reported (such as CPU, DRAM, South Bridge, etc.) I can see the following values: 3.3V 3.152V 5V 4.944V 12V 11.872V Are those the voltages used by peripherals? What voltage should I be referencing if I want to know what my video card (PCI Express) is consuming? What is the normal range of values reported for those? My values above appear to be under by approximately 4.5%, 1.1%, and 1.1% respectively. Is that cause for concern? How else should I be determining if my power supply is "right-sized" for my PC and video card, or am I perhaps barking up the wrong tree?

    Read the article

  • Asus K50I sound issues

    - by MrStatic
    I have an Asus K50IJ (Bestbuy) laptop and have issues with my sound. Speakers themselves work fine but when I plug into the headphone jack it auto mutes the front channel and no sounds comes out of either the speakers or the headphones. If I then unmute the channel I get sound from both the speakers and the headphones. alsamixer shows the Headphone channel as all grayed out. /etc/modprobe.d/alsa-base.conf I have tried snd-hda-intel model="asus-laptop" and snd-hda-intel model="asus" In Sound Preferences I have gone to output and changed the Connector to 'Analog Headphones' that results in no sound from either speakers or headphones. As one forum suggested I tried to comment out blacklist snd_pcsp in the blacklist.conf which resulted in no change. lspci -v shows: 00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) Subsystem: Santa Cruz Operation Device 1043 Flags: bus master, fast devsel, latency 0, IRQ 45 Memory at fe9f4000 (64-bit, non-prefetchable) [size=16K] Capabilities: [50] Power Management version 2 Capabilities: [60] MSI: Enable+ Count=1/1 Maskable- 64bit+ Capabilities: [70] Express Root Complex Integrated Endpoint, MSI 00 Capabilities: [100] Virtual Channel Capabilities: [130] Root Complex Link Kernel driver in use: HDA Intel Kernel modules: snd-hda-intel

    Read the article

  • 2560 x 1600 screen resolution not available when a second monitor is attached.

    - by sgmoore
    I am running Windows 7 (64-bit edition) and have a 30" Dell 3007WFP monitor which runs at a screen resolution of 2560 x 1600. This works perfectly until I try to connect a second monitor, and then the screen resolution on the main monitor immediately drops to 1280x800 and I can't change it back up to the correct resolution until I disconnect the second monitor. The graphics card is a Nvidia Quadro FX 370. This has a dual link DVI connector (to which the 30" is connected) and a single link DVI connector. The second monitor can run at 1920x1080 and is connected using a VGA to DVI connector. Note, it does not seem to matter whether the second monitor is running at 1920x1080 or even at 800x600. Windows reports Total Available Graphics Memory: 3839MB Dedicated Video Memory: 256MB System Video Memory: 0MB Shared System Memory: 3583MB Does anyone know if this a limitation with the video card, memory, drivers, connectors or something else? If this is a limitation with the video card, can anyone recommend a PCI Express 16 card that would support at least this setup, but preferably support two 30" monitors both running 2560 x 1600. (I'm not into gaming etc, so it doesn't need to be very powerful)

    Read the article

  • Problem with Outlook 2010 (SMTP AUTH LOGIN)

    - by Filipe YaBa Polido
    **IGNORE THIS QUESTION - SOLVED WITH A PYTHON SCRIPT available at: http://yabahaus.blogspot.com I have to connect one customer Outlook 2010 to a remote server on which I have either no right, neither way to talk to the sysadmin. This is the thing, after installing and reviewing the logs on Wireshark: Outlook Express: HELO machine AUTH LOGIN username base64 encoded password base64 encoded mails go through. Outlook 2010: HELO machine AUTH DIGEST-MD5 response from server Outlook sends just a * AUTH LOGIN password base64 encoded So... I can send mails in the same domain, but can't send outside, it gives me a relay denied message. My point is... Why the h**l Outlook 2010 doesn't send the username AND the password?! It can never login the right way :| With other versions of Outlook it works fine, and with OE works great, it auths and allows to send mail to a different domain. I've googled and nothing worked. I'm pretty sure that I'm not alone with this one. My last resort will be to configure a local proxy/server that relays to the original one :| Any help would be appreciated. Sorry my bad english as is not my natural language. Thanks.

    Read the article

  • Quickly set up a Windows Server and automatically install and configure software

    - by Chris
    Yesterday I spent far too much time downloading and installing software on Windows Server 2008. I only had to install a simple server for SQL Server 2008 Express using Microsoft's Web Platform Installer, then configure it to enable remote connections. Everything had to be attended, wasting my time. On a Linux system, this would be trivial to automate, but this is Windows. I do this very rarely, but in the future I would like to make this take as little time as possible. I could do a disc image with everything I installed and configured, but is there a better way? I know nothing of advanced deployment techniques on Windows. Ideally I would like to be able to remotely re-install the OS, or have an unattended install (which I know is possible). Any tips to make the software I need easier to and install and configure with minimal interaction necessary would be helpful. I don't expect everything I asked for to be possible and easy to do. Basically, If any part of it can be done quicker or at least without user input, that's what I'm looking for.

    Read the article

  • DPMS does not work: the monitor is not switched off

    - by bortzmeyer
    I have a monitor which was properly switched off by my Debian PC when unused. I attached it to another machine and, this times, it is never switched off. In /etc/X11/xorg.conf, I have: Section "Monitor" Identifier "Generic Monitor" Option "DPMS" It is recognized when X11 starts: (II) Loading extension DPMS ... (II) VESA(0): DPMS capabilities: StandBy Suspend Off; RGB/Color Display ... (**) Option "dpms" (**) VESA(0): DPMS enabled The operating system is Debian stable "lenny". The graphics card is: 00:02.0 VGA compatible controller: Intel Corporation 82G33/G31 Express Integrate d Graphics Controller (rev 02) (prog-if 00 [VGA controller]) Subsystem: Hewlett-Packard Company Device 2a6f Flags: bus master, fast devsel, latency 0, IRQ 5 Memory at fe900000 (32-bit, non-prefetchable) [size=512K] I/O ports at b080 [size=8] Memory at d0000000 (32-bit, prefetchable) [size=256M] Memory at fe800000 (32-bit, non-prefetchable) [size=1M] Capabilities: [90] Message Signalled Interrupts: Mask- 64bit- Queue=0/0 Enable-Capabilities: [d0] Power Management version 2 X11 is: X.Org X Server 1.4.2 Release Date: 11 June 2008 X Protocol Version 11, Revision 0 Build Operating System: Linux Debian (xorg-server 2:1.4.2-10.lenny2) Current Operating System: Linux ludwigVII 2.6.26-2-686 #1 SMP Sun Jun 21 04:57:3 8 UTC 2009 i686 Build Date: 08 June 2009 09:12:57AM

    Read the article

  • Problem with Outlook 2010 (SMTP AUTH LOGIN)

    - by Filipe YaBa Polido
    I have to connect one customer Outlook 2010 to a remote server on which I have either no right, neither way to talk to the sysadmin. This is the thing, after installing and reviewing the logs on Wireshark: Outlook Express: HELO machine AUTH LOGIN username base64 encoded password base64 encoded mails go through. Outlook 2010: HELO machine AUTH DIGEST-MD5 response from server Outlook sends just a * AUTH LOGIN password base64 encoded So... I can send mails in the same domain, but can't send outside, it gives me a relay denied message. My point is... Why the h**l Outlook 2010 doesn't send the username AND the password?! It can never login the right way :| With other versions of Outlook it works fine, and with OE works great, it auths and allows to send mail to a different domain. I've googled and nothing worked. I'm pretty sure that I'm not alone with this one. My last resort will be to configure a local proxy/server that relays to the original one :| Any help would be appreciated. Sorry my bad english as is not my natural language. Thanks.

    Read the article

  • Building vs buying a server for an academic lab [closed]

    - by Roy
    I'm looking for advice on the classic build vs buy question. We need a new linux server to run Matlab computation on in our lab (academic). Matlab parallel computing toolbox licence allows up to 12 local workers so we are aiming at a 12 core server with 4GB memory per core (total of 48gb). The system will have an SSD for the OS and a raid-5 (4x2tb) for data. I looked around and found a (relatively) cheap vendor, Silicon Mechanics, that offers a system to our liking (specs below) for $6732. However, buying the components from newegg cost only $4464! The difference is $2268 which is 50% of the base cost. If buying from a company can be thought of as a sort of insurance, basically my premiums are of 50% of the base cost which to me sounds like a lot. Of course any downtime is bad, but the work is not "mission critical", i.e. if it takes a few days to fix it when it breaks its no the end of the world. If it takes weeks to months then its a problem. If it breaks 2-3 times in 3 years, not too bad. If it breaks every month not good. In term of build experience, I set up a linux cluster in grad school (from existing computers) and I build my home pcs but I never built a server before. The server components I'm thinking about: 1 x SUPERMICRO SYS-7046T-6F 4U Tower Server Barebone Dual LGA 1366 Intel 5520 DDR3 1333/1066/800 ($1,050) 12 x Kingston 4GB 240-Pin DDR3 SDRAM DDR3 1333 (PC3 10600) ECC Unbuffered Server Memory ($420) 2 x Intel Xeon E5645 Westmere-EP 2.4GHz LGA 1366 80W Six-Core ($1,116) 4 x Seagate Constellation ES 2TB 7200 RPM SATA 6.0Gb/s 3.5" ($1,040) 1 x SAMSUNG Internal DVD Writer Black SATA ($20) 1 x Intel 520 Series 2.5" 180GB SATA III MLC SSD $300 1 x LSI LSI00281 PCI-Express 2.0 x8 MD2 Low profile SATA / SAS MegaRAID SAS 9260CV-4i Controller Card, $695

    Read the article

  • Why does the screen resolution of 1440x900 suddenly disappears from Intel GMA Control Panel?

    - by GeneQ
    I'm using a Vostro 1200 laptop with the Mobile Intel(R) 965 Express Chipset powering its graphics and running Vista 32-bit SP2 . I've been using the Vostro with a Dell SE198WFP LCD Monitor as the external display since day one for about two years without any problems. Recently, I plugged the Vostro into a couple of other monitors. The problem is, now the native resolution for my main monitor's (the SE198WFP) resolution of 1440x900 @ 60 Hz is no longer available. (See below) I've tried everything from uninstalling and reinstalling the Intel drivers as well as the monitor drivers to no avail. I've Goggled that this problem and it appears that this has happened to other people but all the answers involve people giving up in frustration or reinstalling; both terrible outcomes. Has anybody ever figured why this happens and have a good solution? Thanks. UPDATE: This dude has a complicated solution, which I haven't tried yet. His explanations for the problem was After an exausting search for an answer to the matter of why my brand new 19? widescreen monitor’s native resolution (1440×900) was unavailible (sic) in the display properties, I finally stumbled upon an article a person posted on Intel’s forums that basically explained what shannanigans Intel had been up to with their GMA 950 line of onboard graphic solutions. Not very comforting.

    Read the article

  • Multiple Video Cards - Stuttering

    - by jstawski
    I have two video cards: - XFX PVT84JUDD3 GeForce 8600GT XXX 256MB 128-bit GDDR3 PCI Express x16 SLI Supported Video Card - EVGA 256-P1-N399-LX GeForce 6200 256MB 64-bit GDDR2 PCI Video Card both running the same set of drivers on Windows 7 64-bit. When I work with 2 monitors connected to the 8600GT card everything works smoothly. When I connect the third one to the 6200 then Windows works well and all of a suddon the screens turns black for up to 5 minutes. Then it goes back and at some random interval it goes black again. I can still see the pointer and hit CTRL+ALT+DEL and see the menu to log off, bring the task manager, etc. I've tried changing the 6200 to another PCI slot and the error persists. I've tried connecting 2 monitors only one to each card, same problem. Tried swapping them, mixed and matched the monitors to see if it was a problem with the monitor and my conclusion was that it is not the monitor. The problem also occurred with Vista 64 as well. What could be generating this problem? Can it be the fact that they are different interfaces? Maybe the Motherboard? Should I change something on the BIOS? What do you guys think?

    Read the article

  • Could I use Windows 7 instead of Windows SBS 2008 for this server?

    - by Ecyrb
    First off, I'm not a sys admin. I'm just a software developer trying to help out my parents' small business. Right now they have one server, a domain controller with a P4 processor running SBS 2003. They also have this machine hosting QuickBooks, MySQL for the old version of an app, and SQL Server 2008 Express for the new version of the app (which will replace the old eventually). They've been complaining about the workstations being slow so I figured it might help if they bought a new server and moved QuickBooks, MySQL, and SQL Server to the new server, leaving the old server as just a DC. In trying to pick an operating system for their new server, I was thinking about Windows SBS 2008 Standard with enough licenses for seven machines. But that's a lot more money than they're going to want to spend. So then I wondered if there's any real advantage to having a server OS as opposed to just throwing Windows 7 on the new server. It's a lot cheaper and I can't think of any SBS features that it would need if it's just hosting QuickBooks, MySQL, and SQL Server. Would it be okay to use Windows 7 for a server like this? Are there any advantages to using SBS 2008 that I would be missing out on? Any additional tips are much appreciated!

    Read the article

  • Requests are making it to my app server, but not into node.js -- why?

    - by Zane Claes
    I detailed in this question on StackOverflow how some random requests are not making it from the client to my Node.js app server, resulting in a gateway timeout. In summary, identical requests are, at random, not even making it far enough to trigger a console.log() in my first line of express middleware. I need to narrow down the problem, though, to find out WHERE the traffic is being lost and it was suggested that I try a packet sniffer on my app servers. Here's my setup: 2x Load Balancers (m1.larges) 2x node.js servers (also m1.large) Here's what's interesting/unusual: the node.js servers started as PHP servers with an Apache stack and continue to serve PHP files for my domain (streamified.me). However, I use a little httpd.conf magic on the app servers so that requests to api.streamified.me get routed over port 8888 to the node.js server: RewriteCond %{HTTP_HOST} ^api.streamified.me RewriteRule ^(.*) http://localhost:8888$1 [P] So, the request hits the load balancer = goes to an app server = gets routed to port 8888 if it's intended for the API = gets handled by node.js So, in the same httpd.conf file, I turned on RewriteLogLevel 5 and then created a simple PHP+CURL script on my localhost to hit my api.streamified.me with a random URL (which should cause node.js to trigger a simple "not found" response) until it resulted in a Gateway timeout. Here, you can see that it has happened -- and the rewrite log shows that the request was definitely received by the app server and forwarded to port 8888... but it was never received by node.js (or, at least, the first line of code in the first line of middleware never gets it...) Image Link: http://i.stack.imgur.com/3OQxS.png

    Read the article

  • Am I able to forward traffic from an external subdomain to a specific local host?

    - by George Bowman
    I apologise in advance if the question doesn't make sense, please let me know. I've got a small LAN (~10 Virtual Servers) using Win Server 2008 as a DNS server. This is behind a smoothwall express 3.0 firewall with ports forwarded for specific services. I have a domain (123-reg) with the NS's that of afraid.org (DynamicDNS) and subdomains pointed to my (Dynamic) IP address e.g. subdomain1.example.com - 123.456.789.101. I think that adequately explains my set up. My question is, am I able to have subdomains e.g. subdomain1.example.com only point to a specific local host? Like so: subdomain1.example.com:80 - firewall(external facing) - server1.example.com:80 subdomain2.example.com:80 - firewall(external facing) - server2.example.com:80 I don't actually necessarily want to use port 80, otherwise I would just use VirtualHosts on apache, it is just an example port. Currently I can use either subdomain1.example.com OR subdomain2.example.com and they will both point to server1.example.com:80 I do not have to stay using Win Server 2008 for DNS, I am more than happy to move over to BIND if needs be, it was just easier to use Win Server 2008's DNS. I do not know if this is even possible, I have a feeling it isn't as I've only got one external IP address but any information is useful!

    Read the article

  • SQL Server 2008 login problem with ASP.NET application: Failed to open the explicitly specified database

    - by eulerfx
    I am running SQL Server 2008 Express Edition on Windows Server 2008 with an ASP.NET application which must access the server. The ASP.NET application is associated with an application pool that runs on the NetworkService account. This account in turn has a Login and User record on SQL Server in the required database. When I attempt to run the ASP.NET website I get a blank page and when viewed in the error log, I seem to be getting this information event record: Login failed for user 'NT AUTHORITY\NETWORK SERVICE'. Reason: Failed to open the explicitly specified database. [CLIENT: myLocalMachine] The connection string has Trusted_Connection=True; and the required database specified. When I explicitly specify the user name and password I get another login error stating the password is incorrect, even though the same un/pw combination works through SQL Server Management studio. The NETWORK SERVICE account seems to have all the required privileges for the database. Also, I made a test ASP.NET website project which does a simple select from a table in that database, and using the same config file I am not getting the error and it seems to work. Is it something to do with trust levels then, because the original ASP.NET web app references various DLLs including open source libraries. Also, the application does not seem to be able to write to the event log itself, throwing a security exception, even though everything in the config files, including machine.config states the app is in full trust.

    Read the article

  • Doesn't VirtualBox 4.0 support drag-drop file copy yet?

    - by Benjamin
    Version 4.0.0 will be new major release. The following major new features were added: -New settings/disk file layout for VM portability; see the manual for more information. -Open Virtualization Format Archive (OVA) support; see the manual for more information. -VMM: support more than 1.5/2 GB guest RAM on 32-bit hosts -Language bindings: uniform Java bindings for both local (COM/XPCOM) and remote (SOAP) -invocation APIs -Chipset: added support for the Intel ICH9 chipset with 3 PCI buses, PCI express and -Message Signaled Interrupts (MSI) -Audio: Intel HD Audio is now available as guest hardware, for better support with modern -guest operating systems (e.g. 64-bit Windows; bug #2785). -GUI: redesigned user interface with guest window preview -GUI: new display mode with downscaled guest display -Resource control: added support for limiting a VM's CPU time and IO bandwidth. -Storage: support asynchronous I/O for iSCSI, VMDK, VHD and Parallels images -Storage: support for resizing VDI and VHD images -Windows Additions: support for automatically updating the Guest Additions (requires -installed Windows Guest Additions 4.0 or later) -Guest Additions: support for copying files into the guest file system What does the last line mean? I thought this is a drag-drop file copy feature like VMWare. I tried that. But I couldn't copy by drag-drop, ctrl-c ctrl-v either. Edit: I mean VBox 4.0 beta, not 3.x The release note is here. Download link is here.

    Read the article

  • Ubuntu 10.04 network manager issues

    - by Shark
    I was using the default network manager to connect to my wi-fi network, but if the connection is dropped or router restarted the network manager wont reconnect automatically after i guess a couple of tries and just gives a pop-up to connect manually . To avoid this annoyance I installed WICD but though it does try to reconnect to the network after a drop in connection it is unable to resolve the ip address and i am left with an even bigger annoyance . 1. Is there a way to counter either of these issues ? 2. Something like a background process that will check network status periodically and then try to connect to a favored network ? Edit- out put of lshw -C network *-network description: Wireless interface product: Broadcom Corporation vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:12:00.0 logical name: eth1 version: 01 serial: c0:cb:38:18:9b:7f width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=wl0 driverversion=5.60.48.36 ip=192.168.11.2 latency=0 multicast=yes wireless=IEEE 802.11 resources: irq:17 memory:fbc00000-fbc03fff *-network description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:13:00.0 logical name: eth0 version: 02 serial: f0:4d:a2:94:2d:74 size: 10MB/s capacity: 100MB/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=half latency=0 link=no multicast=yes port=MII speed=10MB/s resources: irq:29 ioport:e000(size=256) memory:d0b10000-d0b10fff(prefetchable) memory:d0b00000-d0b0ffff(prefetchable) memory:fb200000-fb21ffff(prefetchable)

    Read the article

  • Connecting to a subdomain severs the connection to the domain itself. What's going on?

    - by TheAgent
    Hi all. We have a website on a third-party server (server leased and shared with other websites) and the server provides access to our SQL Server database through a subdomain in the form of mssql.DomainName.com. I was told to use SQL Management Studio Express to connect to this subdomain in order to manage the database. After a few tries and getting many "Timeout" messages, I finally manage to connect to the server; everything's fine. But now I can't connect to DomainName.com anymore. Trying to browse DomainName.com using Firefox, it tries to "lookup" DomainName.com address and fails, telling me "the server was not found". I have to disconnect Management Studio from the server and wait a couple of hour for DomainName.com to become available again, and after that, trying to reconnect to the SQL Server again repeats the scenario. While I can't browse DomainName.com directly, I can use a proxy to connect to it, meaning that the problem is somehow related to a DNS my computer tries to ask to translate the name to the corresponding IP. Anyone seen anything like this before? Any ideas? Thanks in advance.

    Read the article

  • OpenBSD pf - implementing the equivalent of an iptables DNAT

    - by chutz
    The IP address of an internal service is going to change. We have an OpenBSD access point (ssh + autpf rules) where clients connect and open a connection to the internal IP. To give us more time to reconfigure all clients to use the new IP address, I thought we can implement the equivalent of a DNAT on the authpf box. Basically, I want to write a rule similar to this iptables rule which lets me ping both $OLD_IP and $NEW_IP. iptables -t nat -A OUTPUT -d $OLD_IP -j DNAT --to-dest $NEW_IP Our version of OpenBSD is 4.7, but we can upgrade if necessary. If this DNAT is not possible we can probably do a NAT on a firewall along the way. The closest I was able to accomplish on a test box is: pass out on em1 inet proto icmp from any to 10.68.31.99 nat-to 10.68.31.247 Unfortunately, pfctl -s state tells me that nat-to translates the source IP, while I need to translate the destination. $ sudo pfctl -s state all icmp 10.68.31.247:7263 (10.68.30.199:13437) -> 10.68.31.99:8 0:0 I also found lots of mentions about rules that start with rdr and include the -> symbol to express the translation, but it looks like this syntax has been obsoleted in 4.7 and I cannot get anything similar to work. Attempts to implement a rdr fail with a complaint that /etc/pf.conf:20: rdr-to can only be used inbound

    Read the article

  • 3 Monitor PCI-e Graphics card on Linux (without tremendous pain)?

    - by N Rahl
    As we are all painfully aware, the only way to get multiple monitors AND compositing (Compiz) on Linux is to use a single graphics card that can drive both (or in my case all three) screens. I bought a Radeon 5750 specifically because it claims to able to drive 3 monitors. I can plug in 3 monitors (2 DVI, 1 HDMI) and the Catalyst Control Center shows all 3, but only 2 can be enabled at a time. The exact message is: The current settings cannot be applied. Possible issues may include: - Display(s) cannot be enabled. - Setting(s) cannot be applied due to insufficient video memory. So I'm going to assume that either the 5750 doesn't support 3 monitors, OR, more likely, ATI couldn't be bothered to add that support to their Linux drivers. So this is a multipart question: First, can anyone suggest a PCI Express Graphics card that can run 3 screens on linux without tremendous pain? I'm looking for something where you install the driver and all three screens "just work". Does such a card exist? Second, if you have a 5750, have you been able to get it to do 3 monitors? I'm running Ubuntu 10.04 at the moment.

    Read the article

  • Software raid 0 with six disks performance

    - by user134880
    I have some problems with disk performance. I have 6 x WD 500Gb RE4 disks. Each disk gives 135Mb/sec throughput. All measurements are made with hdparm with options "-tT" (I know that it is just synthetic test, but I need some start point to make measurements). I have controller with Sil3124 x 4 ports PCI Express 1x So... RAID0 on controller with 2 disks gives 200Mb/s - ok, pcie limit. RAID0 on motherboard with 2 disks gives 270Mb/s - niceeee :) RAID0 on contorller with 4 disks gives 200Mb/s - ok, pcie limit. RAID0 on controller with 4 disks + 1 disks on motherboard = 340Mb/s ... :( RAID0 on controller with 4 disks + 2 disks on motherboard = 300Mb/s .... why? Any ideas? Maybe need more cpu power? Now there is Pentium D Dual core 2.8Ghz, 4Gb RAM. It is dedicated box for storage.. no other activity.

    Read the article

  • How do I tell Windows to use 802.11 in preference to 3G?

    - by Jon Skeet
    I have a Samsung NC-10 netbook which I take to work every day. Most of the time I use it just on the train/bus, but I also use it at work and home. It has a built-in 3G card which I want to use when travelling, but I'd prefer to use wifi when I'm at work or home, for obvious reasons. Unfortunately, if the 3G connection is up, Windows appears to use that in preference to wifi. Starting up and shutting down the 3G modem is a bit of a pain - it's not hard as such, just a bit inconvenient. Ideally I'd like it to always be up, and even have the connection itself up all the time, but without routing traffic through it if there's a wifi connection up. This is what my Android phone does, for example. Is there somewhere in Windows which lets me express an ordering for network interfaces? I suspect the routing table may be relevant, but it's a bit of a pain to mess around with. I'd really expect there to be a simple GUI way of setting this up - after all, it would equally be useful when dealing with wired vs wifi connections. I'm currently using Windows XP Home, but Windows 7 answers would also be useful as I'll be migrating soon.

    Read the article

  • How to write rules for persistent net names?

    - by ndemou
    I know that a process generates persistent network card names based on rules found in /lib/udev/rules.d/75-persistent-net-generator.rules. I also know how to completely disable this process with a simple echo '#' > /etc/udev/rules.d/75-persistent-net-generator.rules but I've read that I "could also write my own rules file to give the interface a name — the persistent rules generator ignores the interface if a name has already been set" (/etc/udev/rules.d/README confirms that this is possible). Do you have any pointers to documentation about how to write such rules? (I mostly care about Debian/Ubuntu and a bit less for CentOS) As a specific example of why I want to write custom rules: I have two identical servers with one onboard LAN and one PCI LAN. In case of HW failure I want to be able to move disks from HW#1 to HW#2 and it's important for eth0 to continue pointing to the onboard card and eth1 to the PCI card (no one wants to mess with cabling in the middle of a HW failure panic). My current workaround works but is a lot of work[1] so I wonder if writing custom rules would allow me to express something simple like this: cards with MAC A or B should be named eth0 cards with MAC C or D should be named eth1 follow default naming scheme for anything else [1] install the OS in HW#1 and keep a copy of /etc/udev/rules.d/70-persistent-net.rules. Move the disks to HW#2 and keep a second copy of the same file. Concatenate the two copies and manually edit the NAME="ethX" part. Replace /etc/udev/rules.d/70-persistent-net.rules with my version. Finally disable auto-creation of a new 70-persistent-net.rules using echo '#' > /etc/udev/rules.d/75-persistent-net-generator.rules

    Read the article

< Previous Page | 100 101 102 103 104 105 106 107 108 109 110 111  | Next Page >