Search Results

Search found 8706 results on 349 pages for 'dual monitor'.

Page 109/349 | < Previous Page | 105 106 107 108 109 110 111 112 113 114 115 116  | Next Page >

  • double screen in ubuntu 12.04?

    - by johan
    I am using ubuntu 12.04 and my video card is ATI Radeon 5000. I cannot use double screen (extended version). I get this error The selected configuration for displays could not be applied requested position/size for CRTC 148 is outside the allowed limit: position=(1280, 0), size=(1280, 768), maximum=(1440, 1440) I tried all display settings but it does not work. Some outputs from the system settings: root@ubuntu:~# lshw -C display *-display description: VGA compatible controller product: Madison [Radeon HD 5000M Series] vendor: Hynix Semiconductor (Hyundai Electronics) physical id: 0 bus info: pci@0000:01:00.0 version: 00 width: 64 bits clock: 33MHz capabilities: pm pciexpress msi vga_controller bus_master cap_list rom configuration: driver=fglrx_pci latency=0 resources: irq:46 memory:e0000000-efffffff memory:f0020000-f003ffff ioport:d000(size=256) memory:f0000000-f001ffff root@ubuntu:~# aticonfig --initial Uninitialised file found, configuring. Using /etc/X11/xorg.conf Saving back-up to /etc/X11/xorg.conf.original-0 root@ubuntu:~# cat /etc/X11/xorg.conf Section "ServerLayout" Identifier "aticonfig Layout" Screen 0 "aticonfig-Screen[0]-0" 0 0 EndSection Section "Module" Load "glx" EndSection Section "Monitor" Identifier "aticonfig-Monitor[0]-0" Option "VendorName" "ATI Proprietary Driver" Option "ModelName" "Generic Autodetecting Monitor" Option "DPMS" "true" EndSection Section "Device" Identifier "aticonfig-Device[0]-0" Driver "fglrx" BusID "PCI:1:0:0" EndSection Section "Screen" Identifier "Default Screen" DefaultDepth 24 EndSection Section "Screen" Identifier "aticonfig-Screen[0]-0" Device "aticonfig-Device[0]-0" Monitor "aticonfig-Monitor[0]-0" DefaultDepth 24 SubSection "Display" Viewport 0 0 Depth 24 EndSubSection EndSection I would appreciate any suggestions how to solve the problem. Thank you

    Read the article

  • How can I stop Flash from leaving full-screen mode when it loses focus due to a mouse-click in the o

    - by therefromhere
    On a multi-monitor system, if I'm viewing a full-screen video in Flash on one monitor, clicking the mouse on the other monitor causes Flash to leave full-screen mode and revert to normal size. What's the easiest way of preventing this that works on my version of Flash? My system is Flash 10 (10.0.12.36), in Firefox 3.5 on Windows Vista 64, but I think it affects all current versions. This is very annoying behaviour, but unfortunately, according to this bug report response it seem to be a security feature, rather than a bug: We understand that many users would like fullscreen on one monitor and to be able to interact with your OS on another monitor. However, due to security requirements, we require that Flash and Browser must be the current focus of your OS.

    Read the article

  • unable to get into windows 7 or ubuntu after system file back on a dual boot system

    - by John Jiang
    I installed ubuntu on my dell xps 9000 which originally has a window 7 installed. So after I did system file back up as told by windows 7 and restarted my computer, I received the following message right after restarting in the black screen: roughly like this: ubuntu grub error, " " symbol cannot be found. I was wondering how I can get access into windows 7 and uninstall ubuntu all together. I actually had the same booting problem after system backup before and the solution was to install two extra ubuntus but I'd prefer not to do that. I'd highly appreciate any help!

    Read the article

  • How do I start xterm with a headless system?

    - by NeViXa
    I'm running Ubuntu 12.04 and I want to boot directly and headless in the terminal (no GUI). After that I want to startx to start a program in xterm. When I boot 'headed', everything is working like supposed to, but: - When I boot headless, startx is not working (no screens found) I already tried to change xorg.conf to below, but it didn't not work: Section "Device" Identifier "VNC Device" Driver "vesa" EndSection Section "Screen" Identifier "VNC Screen" Device "VNC Device" Monitor "VNC Monitor" SubSection "Display" Modes "1280x1024" EndSubSection EndSection Section "Monitor" Identifier "VNC Monitor" HorizSync 30-70 VertRefresh 50-75 EndSection How can I boot headless and still be able to run startx? ANSWER: Adding the BusID to the Devices section in the xorg.conf above, fixed the problem for me. BusID "PCI:1:00:1"

    Read the article

  • Never update systems tables directly - a study in Agent job scheduling

    It is often recommended that system tables should not be updated directly. Presenting a case in point built around nightly job configuration in order to demonstrate the possible issues with updating system tables directly. What can SQL Monitor 3.2 monitor?Whatever you think is most important. Use custom metrics to monitor and alert on data that's most important for your environment. Find out more.

    Read the article

  • How can I get Xubuntu's workspace switcher to show the proper sized desktop?

    - by Jennifer Jones
    I recently installed the Xubuntu desktop over my Ubuntu 12.04 installation, and have been customizing it to my liking. My laptop comes to class with me, and when it's not out of the room, it's usually connected to a second monitor. When I am not connected to the monitor, the workspace switcher shows that my windows are all inside about half of each workspace, but there's only one monitor connected. I'm looking for a way to get it to show workspaces that are reminiscent of this monitor's size and nothing more. Is there a way to fix that? I can attach a picture of the problem if necessary.

    Read the article

  • Opinions on Dual-Salt authentication for low sensitivity user accounts?

    - by Heleon
    EDIT - Might be useful for someone in the future... Looking around the bcrypt class in php a little more, I think I understand what's going on, and why bcrypt is secure. In essence, I create a random blowfish salt, which contains the number of crypt rounds to perform during the encryption step, which is then hashed using the crypt() function in php. There is no need for me to store the salt I used in the database, because it's not directly needed to decrypt, and the only way to gain a password match to an email address (without knowing the salt values or number of rounds) would be to brute force plain text passwords against the hash stored in the database using the crypt() function to verify, which, if you've got a strong password, would just be more effort than it's worth for the user information i'm storing... I am currently working on a web project requiring user accounts. The application is CodeIgniter on the server side, so I am using Ion Auth as the authentication library. I have written an authentication system before, where I used 2 salts to secure the passwords. One was a server-wide salt which sat as an environment variable in the .htaccess file, and the other was a randomly generated salt which was created at user signup. This was the method I used in that authentication system for hashing the password: $chars = "abcdefghijklmnopqrstuvwxyzABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789"; //create a random string to be used as the random salt for the password hash $size = strlen($chars); for($i = 0; $i < 22; $i++) { $str .= $chars[rand(0, $size - 1)]; } //create the random salt to be used for the crypt $r_blowfish_salt = "$2a$12$" . $str . "$"; //grab the website salt $salt = getenv('WEBSITE_SALT'); //combine the website salt, and the password $password_to_hash = $pwd . $salt; //crypt the password string using blowfish $password = crypt($password_to_hash, $r_blowfish_salt); I have no idea whether this has holes in it or not, but regardless, I moved over to Ion Auth for a more complete set of functions to use with CI. I noticed that Ion only uses a single salt as part of its hashing mechanism (although does recommend that encryption_key is set in order to secure the database session.) The information that will be stored in my database is things like name, email address, location by country, some notes (which will be recommended that they do not contain sensitive information), and a link to a Facebook, Twitter or Flickr account. Based on this, i'm not convinced it's necessary for me to have an SSL connection on the secure pages of my site. My question is, is there a particular reason why only 1 salt is being used as part as the Ion Auth library? Is it implied that I write my own additional salting in front of the functionality it provides, or am I missing something? Furthermore, is it even worth using 2 salts, or once an attacker has the random salt and the hashed password, are all bets off anyway? (I assume not, but worth checking if i'm worrying about nothing...)

    Read the article

  • automatically switch from display 1 to display 2 every x minutes

    - by Jean-Pierre
    I am not that good with programmation, but I guess you are. we are planning to install 2 display monitor in the back of the other one. There will be 1 computer that will display a different application on each display monitor. I want to be able to switch display 1 to 2 and display 2 to display 1 to show what is on the other monitor without having to move themselve on the back of the monitor to see the opposite monitor. I need a script that will switch display every x times. How can I do that ?

    Read the article

  • Cannot enter BIOS due to broken screen

    - by gamer
    Lately my laptop(hp g42 247sb) screen is damaged, so I hook it up with a external monitor(LG something) and it works fine now. But the only annoying thing is I cannot navigate the BIOS menu for some tweaking because the BIOS not shown on the external monitor,instead, it only shown on the broken laptop screen, and it only output to my external monitor when windwos/os is loged-on. So, is there anyway I can force output during BIOS/BOOT/POST to my external monitor? Things I have done and didn't work: (1)Set my LG monitor as primary display on both window properties and Intel Graphics panel (2)Enter the bios (F10 key) and press the fn+F4 key(change display output). (3)Disable and uninstall my internal screen(broken laptop screen) using device manager and restart, but windows(bios?) install it back on log-on. Please help me!

    Read the article

  • NVIDIA X Server TwinView isses with 2 GeForce 8600GT cards

    - by Big Daddy
    Full disclosure, I am relatively new to Linux and loving the learning curve but I am undoubtedly capable of ignorant mistakes I have a rig I am building for my home office desktop. The basics: Gigabyte MB AMD 64bt processor Ubuntu 12.04 64bit two Nvidia GeForce 8600GT video cards using a SLI bridge two 22" DVI input HP monitors So here is my issue (it is driving me nuts) with X Server. If I plug both monitors into GPU 0 X Server auto configures TwinView and all is grand, works like a charm, though both are running off of GPU 0. If I plug one monitor into GPU 0 and one monitor into GPU 1, X Server enables the monitor on GPU 0, sees but keeps the monitor on GPU 1 disabled. My presumption (we all know the saying about presumptions) is that all I would have to do is select the disabled monitor on GPU 1 and drop down the Configure pull down and select TwinView...problem is when the monitors are plugged in this way, the TwinView option is greyed out and can not be selected. What am I not understanding here? Is there some sort of configuration I need to do elsewhere for Ubuntu to utilize both GPU's? Any help will be most appreciated, thanks in advance.

    Read the article

  • Radeon Open Source Drivers Configuration

    - by Andy Turfer
    How does one configure the Radeon Open Source drivers? I have just installed Ubuntu 12.10 and want to try the Open Source drivers instead of the proprietary AMD binaries. After the installation, the driver seems to be installed, I have wobbly windows working (can't use a PC without wobbly windows!), and life is generally good. I have a problem when I connect a secondary monitor. Performance is killed (everything becomes laggy and jerky) and my laptop sits on the right-hand side of the monitor, not the left. I'd like to know how to turn off the Laptop's monitor so I'm just using the external monitor. How can I do this using the Open Source Radeon drivers? I can't find a GUI management tool, and there's no longer an xorg.conf. What to do?

    Read the article

  • Unrecognized Display

    - by Kevin
    I just installed a fresh copy of Ubuntu 12.04, and before I installed drivers, I was able to get my two monitor setup working just fine. However, after updating all my drivers and installing all the recommended software, my second display is no longer detected. My main display is called "Laptop" (which it was detected as the monitor name previously), but it is the only display listed. I tried to detect displays, nothing happened. The monitor is plugged in, and should be working fine - after all, it just was. How can I fix the problem of Ubuntu not listing my second monitor in the display settings?

    Read the article

  • How do I make my monitors show up as two separate monitors? - NVidia GeForce GTX 550 ti

    - by BriGuy92
    I've got a dual-monitor setup, with the monitors configured through the "Nvidia X Server Settings" application. In the Ubuntu Display settings, the monitors show up as one extra-wide monitor labelled "Laptop". Until now, this really hasn't been a problem, but now I'm trying to set up a Wacom tablet. The Ubuntu tablet settings allow the tablet to be mapped to a specific monitor, but since the OS "thinks" that I have only one monitor, I can only map the tablet to both of them. This is a problem. Is there any way to have Ubuntu recognize the monitors separately?

    Read the article

  • Monitoring GWT Website

    - by Raf
    We currently monitor our webapps using curl. More and more of our webapps use the GWT framework, which uses tons of javascript, and we can't rely on our curl system to monitor anymore. Therefore, we search the right tool to monitor, but it seems difficult to find a crawler which is light (no Selenium please) but handles javascript correctly. PS : we host our webapps as well as the probes, we don't want any Internet monitoring service.

    Read the article

  • DVI problem with LG L204WT

    - by Holgerwa
    I have a LG L204WT which has VGA and DVI connectors. Until recently, I have used the monitor via VGA, but now I have upgraded the graphics board and switched to DVI. The problem is that each time after the computer starts, the monitor either doesn't show anything (black screen, but doesn't go into standby) or the picture is distorted. I then switch the monitor off and on several times, and at some point it starts correctly and then I can work as usual. This only happens on startup. It is one out of 3 monitors, the other two work fine. It seems to me as if the monitor is not able to synchronize on the DVI signal and either shows a distorted picture or nothing at all. There are no settings in the monitor setup that would change anything. What could be the problem?

    Read the article

  • Are Intel HD 4000 graphics supported on Ubuntu 10.04 LTS?

    - by user1118764
    I have an intel Core i7-3700 system with Intel HD 4000 integrated graphics with a dual monitor setup (1 connected via VGA, the other via DVI) on Ubuntu 10.04 LTS 64bit. I'm trying to get my monitors correctly detected. Right now, in only 1 unknown monitor is detected with a max resolution of 1280x1024, which is lower than my main monitor connected to DVI. Also, the desktop is mirrored rather than extended. I've previously managed to get a Core i5-2400 system with Intel HD 3000 integrated graphics with the same dual monitor setup and Ubuntu 10.04 LTS 64bit to work using the glasen ppa drivers, but this time, after installing them following the instructions How do I install the Intel HD 3000 video driver? but it doesn't seem to work. Does the Intel HD 4000 require a different driver from the 3000? If so, where can I get it?

    Read the article

  • What is an Acer Converter Port?

    - by ShadowHero
    What is this port "Acer Converter Port"? Very little information can be found on the internet. It's basically the same as miniDP? Can I connect a monitor like Dell U2713H on this one? EDIT From this page: http://acer.custhelp.com/app/answers/detail/a_id/30837/~/frequently-asked-questions-on-the-aspire-r7-series 9. Can I connect a DisplayPort monitor to the Acer Converter Port? The Acer Converter Port uses the same physical port as a Mini DisplayPort, but is designed to connect to an Acer proprietary cable. If you connect a DisplayPort monitor, Acer cannot guarantee the functionality of the monitor. No damage should occur to either monitor or notebook by connecting a Mini DisplayPort cable. So, the question is, can someone confirm this will work for sure?

    Read the article

  • Is there a "dual user check-in" source control system?

    - by Zubair
    Are there any source control systems that require another user to validate the source code "before" it can be checked-in? I want to know as this is one technique to make sure that code quality is high. Update: There has been talk of "Branches" in the answers, and while I feel branches have there place I think that branchs are something different as when a developer's code is ready to go into the main branch it "should" be checked. Most often though I see that when this happens a lead developer or whoever is responsible for the merge into the main branch/stream just puts the code into the main branch as long as it "compiles" and does no more checks than that. I want the idea of two people putting their names to the code at an early stage so that it introduces some responsibility, and also because the code is cheaper to fix early on and is also fresh in the developers mind.

    Read the article

  • How can I increase resolution when impossible to set up nvidia driver?

    - by Asimov4
    I was stuck at 1024x758 before creating an /etc/X11/xorg.conf file as follows which works well to allow me to have a resolution of 1920x1200 with the vesa driver. Section "Device" Identifier "Configured Video Device" Driver "vesa" EndSection Section "Monitor" Identifier "Configured Monitor" HorizSync 24.0 - 83.0 VertRefresh 50.0 - 75.0 EndSection Section "Screen" Identifier "Default Screen" Monitor "Configured Monitor" Device "Configured Video Device" SubSection "Display" Viewport 0 0 Depth 24 Modes "1920x1200" EndSubSection EndSection But now my display is kind of slow. I have an NVIDIA GeForce 8600GT but really cannot find how to set up the driver to work. Are there any alternatives to VESA that would work faster?

    Read the article

  • Practical PowerShell for SQL Server Developers and DBAs – Part 2

    Having shown just how useful PowerShell can be for DBAs in executing queries, Michael Sorens now takes us through navigating SQL Server space and finding meta-information - valuable information for anyone looking to be more productive in SQL Server. What can SQL Monitor 3.2 monitor?Whatever you think is most important. Use custom metrics to monitor and alert on data that's most important for your environment. Find out more.

    Read the article

  • SQLServerCentral Best Practices Clinic: Part 1

    We exposed the SQLServerCentral cluster for monitoring with SQL Monitor. Just like other companies, we have constraints on resources, and we have more work that needs to be done. Help us configure SQLServerCentral’s database servers with your suggestions on what is the highest priority for a website database back end. NEW! SQL Monitor 2.0Monitor SQL Server Central's servers withRed Gate's new SQL Monitor.No installation required. Find out more.

    Read the article

  • Multiple Monitors on One Screen

    - by Hulihan Applications
    Does anyone know of any software/hardware configuration that will allow you to preview/view the contents multiple monitors on one monitor? Let's pretend: I have two monitors hooked up to one pc, Monitor A and Monitor B. The monitors are not near each other. I'd like to be able to preview/see what's displaying on Monitor B on Monitor A I haven't been able to find much about this, but I imagine it may not currently be possible to access/emulate video output going out of a video port in software. However, wouldn't it be possible to capture display data generated by the OS kernel or data getting passed down to the display adapter driver?

    Read the article

< Previous Page | 105 106 107 108 109 110 111 112 113 114 115 116  | Next Page >