Search Results

Search found 6021 results on 241 pages for 'word lens'.

Page 116/241 | < Previous Page | 112 113 114 115 116 117 118 119 120 121 122 123  | Next Page >

  • Using Office 2003 normal.dot in Office 2010?

    - by TJ
    I have a user who I have upgraded from office 2003 to Office 2010. This user relies on his custom auto correct that he built into his normal.dot file for Word 2003. He would not like to have to reenter all 200 of his auto corrects. How can I convert his old Normal.dot file with auto corrects to the new Normal.dot for Office 2010?

    Read the article

  • Ofice for Mac 2011 does not start, how do I repair the database?

    - by RomanT
    After a TimeMachine restore; Office 2011 is having kittens over permissions it would seem. Having attempted a 'repair' out of Disk Utility, am still seeing: there is a problem with the Office database upon startup, after which Word/Excel work without issues. Outlook on the other hand won't even start. Given the obvious message here "You do not have write access to the Outlook application folder" – where is the DB located to check?

    Read the article

  • Just to not to be ingnorant.

    - by atch
    Could anyone explain to me why is it that producers of processors claim that their processor can perform so many thousands (or millions) operations per second and yet typical program (Word, VS etc.) on my machine with 4GB, 3500hz starts with no less than 10sek. Have to mention that I've just formatted disk and tick any necessarry boxes to optimize my machine. So if for example outlook starts in 10 sek I wonder how many millions of operations have to be performed to run such program? Thanks

    Read the article

  • What would an Outlook 2007 macro to automate Paste Special - Unformatted Text look like?

    - by Gary Petersen
    I'd like to assign a macro in Outlook 2007 to a Toolbar button that would execute the equivalent of these clicks when there is formatted text in the Windows clipboard: Click the Paste icon by the bottom arrow Click the Paste Special link. Click the Unformatted Text link. I have similar macros in Excel 2007 and Word 2007 but haven't been able to get one to work in Outlook 2007 / VBA. What would the VBA code for such a macro be?

    Read the article

  • Can I import an outline into powerpoint

    - by justintime
    I would like to create a bullet point powerpoint in a text file (or Word document) and then import it into Powerpoint 2007 Slide 1 title - bullet 1 - bullet 2 - subpoint - bullet 3 Slide 2 title - bullet 1 - bullet 2 I find that powerpoint makes one think too much about form to the exclusion of content. Answers of the form Don't use Powerpoint might not go down to well with our corporate presentation style police !

    Read the article

  • Sync my files across multiple computers

    - by EnderMB
    I do a lot of work on my home computer, ranging from programming, writing stored procedures and writing documentation and reporting. A lot of this work is university related and constantly swapping files across several computers is annoying at best. I have a large final-year project coming up and I'm going to be sharing this work amongst home and university and require some kind of online storage that provides version control for my programs, as well as my Word documents, PDF's and saved academic papers. Are there any good solutions for my problem?

    Read the article

  • CLI Text editor with rtf capabilities for Windows

    - by dassouki
    I'm looking for a command line interface program that gives me the ability to write formatted text easily interoperable with MS Word and OpenOffice. I figured RTF would be the common ground. An example of what I was hoping for would be: [Heading 1] Hello Heading [Paragraph Style 1] My name is hello world, I'm awesome.

    Read the article

  • Can't copy and paste into outlook 2003 from any other aplication

    - by Shard
    I am having an issue with outlook 2003 where i cannot copy and paste anything from any other application into a email that i am working on. I have tried copying from excel, word, notepad and from a web browser. I can confirm that i can copy and paste parts from the same email. Has anyone come across this issue before and/or know of a solution?

    Read the article

  • Mac 10.6.7 Firefox office 2011 file association for all users

    - by Sandman
    I need to work out a way to have Firefox 4 or 3.6 on OSX to auto open Word, Excel and Powerpoint file types from a local intranet. I have setup Firefox under a localuseradmin with the file types set to open automaticly and then I copied the Firefox/Mozilla folders into the /system/library/user template/ but when a new user logs in the file type association is set back to default when Firefox runs.

    Read the article

  • What the heck is a OPTIONS method in a IIS 7.5 web Log?

    - by Knox
    I know what a GET and a POST are, but it's almost impossible to Google for the word OPTIONS. Here's what I see (i deleted all the stuff at the end) of each: 11/23/11 0:02:13 10.100.0.14 GET /CUpdate2.cshtml _=1322006533495 11/23/11 0:02:13 10.200.0.10 OPTIONS /AssignmentCount _=1322006576798 11/23/11 0:02:13 10.200.0.10 GET /media/faxSound.wav - 11/23/11 0:02:13 10.200.0.10 GET /Star/StarUpdates _=1322006578729 11/23/11 0:02:13 10.100.0.10 GET /CUpdate2.cshtml _=1322006533268

    Read the article

  • Google Chrome Interferes with Copy and Paste in Excel

    - by Dan
    I have got a following problem: Copy (Ctrl+C) and Paste (Ctrl+V) function in Excel 2010 does not work (or acts weirdly) is I have Google Chrome opened at the same time. This issue is Excel-specific meaning that in Word or Powerpoint copy/paste works fine. It is also Chrome- and CoolNovo-specific as the copy/paste in Excel does not interfere with other internet browsers. Any suggestions? Cheers, Dan

    Read the article

  • Promote document data to meta-data

    - by antony.trupe
    Is there a way to "promote" information in a document(Word, Visio, etc) to "meta-data" that can be auto-magically represented in a SharePoint list? I want to be able to create metrics on information in documents without duplicating the data in the document in a column of the list.

    Read the article

  • Does the DisplayPort on the Dell UltraSharp U2311H Monitor work with a MacBook Pro?

    - by GeneQ
    I'm thinking of getting the Dell UltraSharp U2311H monitor which apparently comes with a DisplayPort. (I used the word "apparently" because I find DisplayPort support a little bit too good to be true, coming from Dell. But great news nonetheless if it's really true) I plan to connect it to a Mac Book Pro (2010) via a mini DisplayPort to DisplayPort cable. Has anyone tried this setup? Does it work? Thanks.

    Read the article

  • How to copy-paste in good quality from Adobe Illustrator to MS One Note?

    - by Suzan Cioc
    When I copy some drawing in Illustrator, it stores it in clipboard in 3 formats: bitmap, device independent bitmap and enhanced meta-file. If drawing contains text, then meta-file version has no anti-aliasing. Below are examples in MS Word OneNote has no "Paste Special" so it always paste in EMF. Is it possible either to tell OneNote to paste not in EMF, or tell Illustrator to use anti-aliasing while storing picture with letters?

    Read the article

  • Stop Search param in directories by grep immediately after param match

    - by yael
    hi friends I use the following command to find under /var some param in my script grep -R "param" /var/* 2/dev/null |grep -wq "param" my problem is that: after grep find the param in file grep continue to search until all searches under /var/* will completed How to perform stop immediately after grep match the param word For example when I run the: grep -R "param" /var/* 2/dev/null |grep -wq "param" grep find the param after one second. But grep continue to Search other same param on other files and its take almost 30 seconds How to stop the grep immediately after param match? THX

    Read the article

  • How can I disable Control-W in Windows XP?

    - by Tim Visher
    I'm an Emacs/Mac user trapped on Windows at work and I often type Control-W from muscle memory to delete a word and thus by mistake kill the entire window, including everything that I was working on. This a particularly egregious problem for Console2 as I run GNU Screen and am often doing many things at once. Is there any way to completely disable Control-W or remap it to something that is far harder to type? Thanks!

    Read the article

  • Creating limited user account on Windows 7

    - by serena
    I'm sharing my PC (Win 7 x64 Home Premium) with a friend, and I wanna create a guest user for her. I don't want her to reach my files, Windows settings, program adjustments etc. She should just surf the net, create/edit her own Word, Excel documents, and simple things like these. How can I create this user account and make the necessary arrangements for limitations?

    Read the article

  • Remove the Microsoft Security Essentials icon

    - by unam3d
    I've been using Microsoft Security Essentials on Windows 7 for sometime now and so far I don't have a bad word to say about it. I would like to permanently remove the MSE icon from the task bar and pop-up box, though I would still like to be informed when it detects a threat, etc.

    Read the article

  • How do I add a version number field to an office 2007 docx document?

    - by Jon Cage
    I've been having a crack at using fields in Word 2007 and have hit a slight stumbling block. I want to add a field which I can use in several parts of the document to represent the current version (something of the form v0.1 but I can't see an obvious way to do it). The only provision I've found for this is something called RevNum but that gets updated every time I save the document. Is there a field I've missed or a way of adding custom fields or something?

    Read the article

  • How to get rid of prompts for credentials connecting to proxy Server officeimg.vo.msecnd.net in Office 2013?

    - by Firee
    I have experienced this issue mainly with Excel, Word and Powerpoint 2013, where there is constant pop-up box asking for login credentials as it tries to connect to officeimg.vo.msecnd.net I have searched and found one of the solution, to prevent Office from connecting to the internet (Options Trust Center Settings Allow Office to connect to internet). This solution worked for sometime, but am back to square one again. Solutions are sought, as this is a nagging problem, I am sure others would have experienced the same.

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

  • Keys getting stuck

    - by Pongus
    I am running a desktop with Vista. At random points when typing I will press a key, the key will stick. I will get multiple keypressesssssssssssssssssss. (for example what just happened at the end of that last word!) Any ideas what is causing this? I dont even know where to start looking here..

    Read the article

< Previous Page | 112 113 114 115 116 117 118 119 120 121 122 123  | Next Page >