Search Results

Search found 1650 results on 66 pages for 'sas san'.

Page 15/66 | < Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >

  • New Write Flash SSDs and more disk trays

    - by Steve Tunstall
    In case you haven't heard, the Write SSDs the ZFSSA have been updated. Much faster now for the same price. Sweet. The new write-flash SSDs have a new part number of 7105026 , so make sure you order the right ones. It's important to note that you MUST be on code level 2011.1.4.0 or higher to use these. They have increased in IOPS from 6,000 to 11,000, and increased throughput from 200MB/s to 350MB/s.    Also, you can now add six SAS HBAs (up from 4) to the 7420, allowing one to have three SAS channels with 12 disk trays each, for a new total of 36 disk trays. With 3TB drives, that's 2.5 Petabytes. Is that enough for you? Make sure you add new cards to the correct slots. I've talked about this before, but here is the handy-dandy matrix again so you don't have to go find it. Remember the rules: You can have 6 of any one kind of card (like six 10GigE cards), but you only really get 8 slots, since you have two SAS cards no matter what. If you want more than 12 disk trays, you need two more SAS cards, so think about expansion later, too. In fact, if you are going to have two different speeds of drives, in other words you want to mix 15K speed and 7,200 speed drives in the same system, I would highly recommend two different SAS channels. So I would want four SAS cards in that system, no matter how many trays you have. 

    Read the article

  • L'édition 2010 de la WWDC se tiendra du 7 au 11 juin 2010 à San Francisco, une édition qui s'adresse

    Voilà, Apple a enfin annoncé officiellement la tenue de la réunion mondiale des développeurs d'applications pour les produits Apple. Et cette édition 2010 s'adresse principalement, pour ne pas pas dire totalement aux développeurs pour iPhone OS. En effet, la toute grosse majorité des sessions et labos sont consacrées à l'iPhone OS et aux framework qu'on retrouve dans l'iPhone SDK Les rares fois où une session concerne Mac OS X, c'est pour expliquer comment configurer XCode, EDI utilisé également pour l'iPhone OS. Peut-être que l'édition 2011 sera plus axée, elle, sur Mac OS X, en mettant l'accent sur Mac OS X 10.7. Source : http://developer.apple.co...

    Read the article

  • How to mount a iSCSI/SAN storage drive to a stable device name (one that can't change on re-connect)?

    - by jcalfee314
    We need stable device paths for our Twinstrata SAN drives. Many guides for setting up iSCSI connectors simply say to use a device path like /dev/sda or /dev/sdb. This is far from correct, I doubt that any setup exists that would be happy to have its device name suddenly change (from /dev/sda to /dev/sdb for example). The fix I found was to install multipath and start a multipathd on boot which then provides a stable mapping between the storage's WWID to a device path like this /dev/mapper/firebird_database. This is a method described in the CentOS/RedHat here: http://www.centos.org/docs/5/html/5.1/DM_Multipath/setup_procedure.html. This seems a little complicated though. We noticed that it is common to see UUIDs appear in fstab on new installs. So, the question is, why do we need an external program (multipathd) running to provide a stable device mount? Should there be a way to provide the WWID directly in /etc/fstab?

    Read the article

  • Decyphering Seagate drive model numbers?

    - by Stefan Lasiewski
    I'm comparing Seagate's Enterprise and Desktop drives for a variety of old and new servers. These servers come from different generations, so options like size (73GB, 2TB) and interface (SATA vs SAS 3.0Gbps vs SAS 6Gbps vs SCSI Ultra320) are widely variable. I'm trying to compare the sizes, speeds and interfaces, but I'm getting thrown off by different models. Also, their website is not the best. Does anyone know of a documented explanation of the Seagate model numbers? And is there a single spreadsheet which compares the features for all drives (or all 'Enterprise' drives?). Seagate drives have model numbers like this: Model ST3600057SS 6-Gb/s SAS 600 GB None at Cheetah® 15K Hard Drives Model ST373455LW Ultra320 SCSI 73.4 GB 68-Pin LW at Cheetah® 15K Hard Drives Model ST32000644NS SATA 3Gb/s 2 TB None at Constellation™ ES Hard Drives Model ST973452SS 6-Gb/s SAS 73 GB None Savvio® 15K Hard Drives Model ST9200011FS SATA 3Gb/s 200 GB Pulsar™ Solid State Drives I understand the model numbers read something like this: ST - SOMETHING1 - SIZE - SOMETHING2 - INTERFACE Where the fields mean something like this: ST : For 'Seagate'? 'Seagate Technoligies'? SOMETHING1 - This field has number, but I'm not sure what that represents. SIZE - Size in Gigabytes. This is a number like '73' or '300' or '2000' SOMETHING2 - This field also has a number, but I'm not sure what it means. INTERFACE - This field seems to indicate the Interface. 'SS' means SAS, 'FC' means Fibre Channel, but I don't see how to distinguish between 6Gbps SAS and 3Gbps SAS, or different SATA or FC speeds. I don't see a field which indicates the RPM (15K , 10K, 7.2K) etc. Is this part of the model number?

    Read the article

  • Can't Remove Logical Drive/Array from HP P400

    - by Myles
    This is my first post here. Thank you in advance for any assistance with this matter. I'm trying to remove a logical drive (logical drive 2) and an array (array "B") from my Smart Array P400. The host is a DL580 G5 running 64-bit Red Hat Enterprise Linux Server release 5.7 (Tikanga). I am unable to remove the array using either hpacucli or cpqacuxe. I believe it is because of "OS Status: LOCKED". The file system that lives on this array has been unmounted. I do not want to reboot the host. Is there some way to "release" this logical drive so I can remove the array? Note that I do not need to preserve the data on logical drive 2. I intend to physically remove the drives from the machine and replace them with larger drives. I'm using the cciss kernel module that ships with Red Hat 5.7. Here is some information pertaining to the host and the P400 configuration: [root@gort ~]# cat /etc/redhat-release Red Hat Enterprise Linux Server release 5.7 (Tikanga) [root@gort ~]# uname -a Linux gort 2.6.18-274.el5 #1 SMP Fri Jul 8 17:36:59 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux [root@gort ~]# rpm -qa | egrep '^(hp|cpq)' cpqacuxe-9.30-15.0 hp-health-9.25-1551.7.rhel5 hpsmh-7.1.2-3 hpdiags-9.3.0-466 hponcfg-3.1.0-0 hp-snmp-agents-9.25-2384.8.rhel5 hpacucli-9.30-15.0 [root@gort ~]# hpacucli HP Array Configuration Utility CLI 9.30.15.0 Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console. => ctrl all show config detail Smart Array P400 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Cache Serial Number: PA82C0J9SVW34U RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware Revision: D Firmware Version: 7.22 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 128 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Unique Identifier: 600508B100184A395356573334550002 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 101 MB, /tmp 7.8 GB, /usr 3.9 GB, /usr/local 2.0 GB, /var 3.9 GB, / 2.0 GB, /local 113.2 GB OS Status: LOCKED Logical Drive Label: A0027AA78DEE Mirror Group 0: physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) Drive Type: Data Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM57RF40000983878FX Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 35 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM55VQC000098388524 Model: HP DG146BB976 Current Temperature (C): 29 Maximum Temperature (C): 36 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Logical Drive: 2 Size: 546.8 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 256 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Completed Unique Identifier: 600508B100184A395356573334550003 Disk Name: /dev/cciss/c0d1 Mount Points: None OS Status: LOCKED Logical Drive Label: A5C9C6F81504 Drive Type: Data Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data physicaldrive 1I:1:3 Port: 1I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2H5PE00009802NK19 Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 37 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 1I:1:4 Port: 1I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM28YY400009750MKPJ Model: HP DG146ABAB4 Current Temperature (C): 31 Maximum Temperature (C): 36 PHY Count: 1 PHY Transfer Rate: 3.0Gbps physicaldrive 2I:1:5 Port: 2I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FGYV00009802N3GN Model: HP DG146ABAB4 Current Temperature (C): 30 Maximum Temperature (C): 38 PHY Count: 1 PHY Transfer Rate: Unknown physicaldrive 2I:1:6 Port: 2I Box: 1 Bay: 6 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM8AFAK00009920MMV1 Model: HP DG146BB976 Current Temperature (C): 31 Maximum Temperature (C): 41 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:7 Port: 2I Box: 1 Bay: 7 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 10000 Firmware Revision: HPDE Serial Number: 3NM2FJQD00009801MSHQ Model: HP DG146ABAB4 Current Temperature (C): 29 Maximum Temperature (C): 39 PHY Count: 1 PHY Transfer Rate: Unknown

    Read the article

  • What is Best storage servers infrastructure ? DAS/NAS/SAN or installing GlusterFS/LUSTER/HDFS/RBDB

    - by TORr0t
    I am trying to design an infrastucture for the project I am working on. It would be somehow a file-sharing/downloading project (like rapidshare) and I would need high storage sizes and good scability, and I would add new storage nodes after my project grows up. I have come up with 3 solutions for my project which are using Luster, GlusterFS, HDFS, RDBD. For start, i would have 2 servers, one server is for glusterfs client + webserver + db server+ a streaming server, and the other server is gluster storage node. (After sometime, i would be adding more node servers, and client servers (dont know how many new client new servers to add, will see later) So, i am thinking to work with glusterfs. But i really wonder that if i have to use high performance servers with high sotrage sizes or avarage/slow servers with high storage sizes? Or nas/das/san solutions are better for glusterfs storage nodes? I might buy a nas and install glusterfs onto it. I would be happy to listen to your recommendations for the server properties (for each clients and nodes) . I really dont know if I really need high amount of ram and good cpus to for the nodes. I am sure i need it for client servers. The files would be streamed as well, so the Automatic file replication is important, thus, my system should work like a cloud, when needed, according to high traffic, the storage nodes should copy the most demanded file to be streamed and would help me to get rid of scability problems and my visitors would able to stream/download those files. Also, i am open to your experiences/thoughts about any good solution. Luster, hdfs, rbdb are the other options and i would be happy to listen to your thoughts here. I would be very very happy to hear back from anyone commented of any words I have used here. Thanks

    Read the article

  • JCP Party at JavOne and other JCP events

    - by heathervc
    Don't miss all of these great opportunities to get involved with the JCP program at JavaOne next week. The details are listed below and listed on the JCP at JavaOne page  as well. Join us for the annual JCP community party on Tuesday evening, 2 October, to be held at the Infusion Lounge. Drop by starting at 6:30 pm to meet fellow Java Community members, JCP members and EC representatives, enjoy appetizers/beer, pick up a door prize, enter a raffle and congratulate the winners and nominees (newly updated nominee information available now) of the 10th annual awards in three categories: JCP Member of the Year, Outstanding Spec Lead, and Most Significant JSR. The day by day breakdown is as follows... Sunday 9/30/12JCP and OpenJDK: Using the JUGs' "Adopt" Programs in Your Group Session ID: UGF10434Location: Moscone West - 2002Date and Time: 9/30/12, 12:15 PM - 1:00 PMJCP Public Executive Committee Face-to-Face Meeting Open to Executive Committee Members and the Java Developer CommunityLocation: Clift Hotel, 495 Geary Street, San Francisco - Rita Room (downstairs from Lobby)Date and Time: 9/30/12, 2:00 PM - 3:30 PM; Agenda includes open Q&A, JCP.Next, EC Elections - no JavaOne pass required! Monday 10/1/12JCP in the OTN Java DEMOgrounds Location: Hilton Hotel Grand BallroomDate and Time: 10/1/12, 4:00 PM - 4:30 PMJCP.Next: Reinvigorating Java Standards Session ID: BOF6272Location: Hilton San Francisco - Plaza A/BDate and Time: 10/1/12, 4:30 PM - 5:15 PM101 Ways to Improve Java: Why Developer Participation Matters Session ID: BOF6283Location: Hilton San Francisco - Continental Ballroom 4Date and Time: 10/1/12, 5:30 PM - 6:15 PM Tuesday 10/2/12JCP in the OTN Java DEMOgrounds Location: Hilton Hotel Grand BallroomDate and Time: 10/2/12, 12:00 PM - 1:30 PMSpec Leads Meeting with the JCP PMO Location: Hilton San Francisco - Van Ness RoomDate and Time: 10/2/12, 3:00 PM - 4:00 PMCome learn how you benefit from the changesMeet the JCP Executive Committee Candidates Session ID: BOF6307Location: Hilton San Francisco - Golden Gate 3/4/5Date and Time: 10/2/12, 4:30 PM - 5:15 PMThe 10th Annual JCP Awards Presentation and Party Enjoy an evening with this year's JCP Award nominees and watch as we announce the winners -  no JavaOne pass required! Location: Infusion Lounge - 124 Ellis Street, San FranciscoDate and Time: 10/2/12, 6:30 PM - 9:00 PM Hope to see you there!

    Read the article

  • Java Deployment Team at JavaOne 2012

    - by _chrisb
    This year the Java Deployment team has some pretty exciting sessions at JavaOne. We will be talking about a lot of new features including Java on the Mac, Java FX deployment, and bundled applications. All presentations and the booth are located at the Hilton San Francisco Union Square, 333 O'Farrell Street. Booth The Java Deployment booth is located in the Hilton San Francisco Grand Ballroom. We will available to discuss Java Deployment and answer your questions at the following days and times: Monday, October 1st 10:30 AM - 5:00 PM Tuesday, October 2nd 10:00 AM - 5:00 PM Wednesday, October 3rd 9:30 AM - 5:00 PM Sessions Java Deployment on Mac OS X - CON7488 This is a great opportunity to learn about what's new in Java for Mac. Oracle now distributes Java for Mac so there are some exciting new changes. Scott Kovatch and Chris Bensen Located in the Hilton San Francisco Imperial Ballroom B Monday, October 1, 1:00 PM - 2:00 PM Deploy Your Application with OpenJDK 7 on Mac OS X - CON8224 Learn about packaging and distributing Java applications to the Mac AppStore with step by step examples and tips. Scott Kovatch Located in the Hilton San Francisco Imperial Ballroom B Monday, October 1, 3:00 PM - 4:00 PM The Java User Experience Team Presents the Latest UI Updates - BOF3615 Discover the eye candy that the user interface experts have been working on. Jeff Hoffman and Terri Yamamoto Located in the Hilton San Francisco Imperial Ballroom B Monday, October 1, 5:30 PM - 6:15 PM Mastering Java Deployment Skills - CON7797 Find out what Java Deployment has been cooking. This is the best place to learn about self-contained application packaging. Igor Nekrestyanov and Mark Howe Located in the Hilton San Francisco Imperial Ballroom B Thursday, October 4th, 12:30 PM to 1:30 PM For those who will not be able to aqttend we will share all slides after the JavaOne. And just to make it easy to find us, here is a map: View Larger Map

    Read the article

  • CD/DVD drive not mounted when inserted with Disc of any kind

    - by Cisco Sán
    I just noticed that if a insert a CD or a DVD of any kind, the Drive will start spinning but it will not show the mounted disc. Before it used to ask me what to do with the media inserted. Now it doesn't even do that. I ran in the terminal this code: eject -n and it displays this: " eject: device is `/dev/sr0'" what can I do to get the functionality back on my drive. also ran this command: sudo mount -o ro,unhide,uid=1000 /dev/cdrom /mnt/cdrom but in return i get this: " mount: mount point /mnt/cdrom does not exist" Running Ubuntu 11.10 HERE IS THE HISTORY UNTIL NOW thanks Waltinator: I ran the 'dmesg' but don't know what I'm looking for. Im a newbie on this. The same thing with the 'ls -rlt /var/log' command. Should I create the directory for the mount? at this point really don't know what to do. – Cisco Sán 7 hours ago Here are 3 lines from my dmesg after I successfully inserted a CD: [ 4804.416018] wlan0: no IPv6 routers present [ 8214.125450] ISdit ISO 9660 Extensions: Microsoft Joliet Level 3 [ 8214.136556] ISO 9660 Extensions: RRIP_1991A The first line is a previous event, my wireless going online. The next 2 lines are a good result. The number in square brackets is "seconds since boot", the rest of the line is usually helpful. And no, you should NOT create the mount point. Let's try to get the automatic mounting to work. – waltinator 7 hours ago ok this are my last 3 lines on the 'dmesg' [ 18.130819] init: plymouth-stop pre-start process (1396) terminated with status 1 [ 28.780011] wlan0: no IPv6 routers present [ 505.632119] CE: hpet increased min_delta_ns to 20113 nsec – Cisco Sán 6 hours ago It looks like your CD/DVD drive is not connected to the data bus, and not causing an interrupt when you insert a platter. – waltinator 6 hours ago Try dmesg | grep -A8 CD-ROM which should show you what the system thought was available when it came up. – waltinator 6 hours ago here is my printout [0.774351] scsi 0:0:0:0: CD-ROM HL-DT-ST DVD+-RW GSA-T40N A100 PQ: 0 ANSI: 5 [0.778117] sr0: scsi3-mmc drive: 24x/24x writer dvd-ram cd/rw xa/form2 cdda tray [0.778122] cdrom: Uniform CD-ROM driver Revision: 3.20 [0.778282] sr 0:0:0:0: Attached scsi CD-ROM sr0 [0.778340] sr 0:0:0:0: Attached scsi generic sg0 type 5 [0.780416] Freeing unused kernel memory: 984k freed [0.780732] Write protecting the kernel read-only data: 10240k [0.780986] Freeing unused kernel memory: 20k freed [0.786331] Freeing unused kernel memory: 1400k freed [0.804912] udevd[90]: starting version 173 [0.874178] r8169 Gigabit Ethernet driver 2.3LK-NAPI loaded [0.874208] r8169 0000:02:00.0: PCI INT A - GSI 16 (level, low) - IRQ 16 OK, your system sees the drive. Can you open and close the tray with eject and eject -t? Run udevadm monitor while you insert a CD (type ^C when done) and see if you get "change" and "add" messages. – waltinator 6 hours ago ok, "eject" works perfectly "eject -t" does nothing. this is the message for "udevadm monitor": KERNEL[13771.009267] change /devices/pci0000:00/0000:00:1f.1/host0/target0:0:0/0:0:0:0/block/sr0 (block) UDEV [13773.878887] change /devices/pci0000:00/0000:00:1f.1/host0/target0:0:0/0:0:0 /block/sr0 (block) – Cisco Sán 6 hours ago sudo hwinfo --cdrom (the hwinfo package is installable through Software Center) describes my CD-ROM, try it. – waltinator 4 hours ago My read out from the "sudo hwinfo --cdrom" are the following: hal.1: read hal dataprocess 2753: arguments to dbus_move_error() were incorrect, assertion "(dest) == NULL || !dbus_error_is_set ((dest))" failed in file ../../dbus/dbus-errors.c line 280. This is normally a bug in some application using the D-Bus library. libhal.c 3483 : Error unsubscribing to signals, error=The name org.freedesktop.Hal was not provided by any .service files 22: SCSI 00.0: 10602 CD-ROM (DVD) [Created at block.247] Unique ID: KD9E.JgkxTS4hgl2 Parent ID: 3p2J.gdUMCD83e+E SysFS ID: /class/block/sr0 SysFS BusID: 0:0:0:0 SysFS Device Link: /devices/pci0000:00/0000:00:1f.1/host0/target0:0:0/0:0:0:0 Hardware Class: cdrom Model: "HL-DT-ST DVD+-RW GSA-T40N" Vendor: "HL-DT-ST" Device: "DVD+-RW GSA-T40N" Revision: "A100" Driver: "ata_piix", "sr" Driver Modules: "ata_piix" Device File: /dev/sr0 (/dev/sg0) Device Files: /dev/sr0, /dev/scd0, /dev/disk/by-id/ata-HL-DT-ST_DVD+_-RW_GSA-T40N_K048BJ74257, /dev/disk/by-path/pci-0000:00:1f.1-scsi-0:0:0:0, /dev/cdrom, /dev/cdrw, /dev/dvd, /dev/dvdrw Device Number: block 11:0 (char 21:0) Features: DVD Config Status: cfg=new, avail=yes, need=no, active=unknown Attached to: #17 (IDE interface) Drive Speed: 31 Volume ID: "Movie" Publisher: "INTERVIDEO" Creation date: "20050424162207000" Thanks for the help. To Castro, hope this is what you meant and sorry for the comments..

    Read the article

  • How to understand the LSI HBA connector specs?

    - by Sandra
    When reading the specifications for the LSi SAS 9206-16e HBA, it says Storage Connectivity; Data Transfer Rates * 16 ports; 6Gb/s SAS 2.1 compliant SAS Bandwidth * Half Duplex 2400MB/s, x4, 6Gb/s SAS lanes Port Configurations * 16 ea, x1 ports (individual drives) * 4 ea, x4 wide ports * 2ea, x8 wide ports Connectors * Four (x4) mini-SAS HD external connectors (SFF8644) So there are 4 physical connectors. Question What is the bandwidth for each of the connectors? I would be temped to say 6Gb/s * 4, but then it mentions the "Port Configurations" and 2ea, 4ea, 16ea, which I don't understand what is. Does this mean, that the 4 physical connectors are not identical?

    Read the article

  • Dell R910 with Integrated PERC H700 Adapter

    - by Alex
    I am in the process of designing an architecture based around a single Dell R910 server running Windows Server 2008 Enterprise. I would like the server to have 8 RAID1 pairs of spinning disks, so I intend to implement: Dell R910 Server Integrated PERC H700 Adapter with 1 SAS expander on each SAS connector (so 8 expanders in total) 7 RAID1 pairs of 143Gb 15K HDD, each paired on one connector using an expander 1 RAID1 pair of 600Gb 10K HDD, paired on the remaining connector using an expander My main concern is not to introduce bottlenecks in this architecture, and I have the following questions. Will the PERC H700 Adapter act as a bottleneck for disk access? Will using SAS expanders for each RAID1 pair cause a bottleneck or would this be as fast as pairing disks directly attached to the SAS connectors? Can I mix the disks, as long as the disks in each RAID1 pair are the same? I assume so. Can anyone recommend any single-to-double SAS Expanders that are known to function well with the H700? Cheers Alex

    Read the article

  • OS8- AK8- The bad news...

    - by Steve Tunstall
    Ok I told you I would give you the bad news of AK8 to go along with all the cool new stuff, so here it is. It's not that bad, really, just things you need to be aware of. First, the 2013.1 code is being called OS8, AK8 and 2013.1 by different people. I mean different people INSIDE Oracle!! It was supposed to be easy, but it never is. So for the rest of this blog entry, I'm calling it AK8. AK8 is not compatible with the 7x10 series. Ever. The 7x10 series is not supported with AK8, and if you try to upgrade one, it will fail at the healthcheck. All 7x20 series, all of them regardless of age, are supported with AK8. Drive trays. Let's talk about drive trays and SAS cards. The older drive trays for the 7x20 series were called the "Riverwalk 2" or "DS2" trays. They were technically the "J4410" series JBODs that Sun used to sell a la carte before we stopped selling JBODs. Don't get me started on that, it still makes me mad. We used these for many years, and you can still buy them right now until December 15th, 2013, when they will no longer be sold. The DS2 tray only came as a 4u, 24 drive shelf. It held 3.5" drives, and you had a choice of 2TB, 3TB, 300GB or 600GB drives. The SAS HBA in the 7x20 series was called a "Thebe" card, with a part # of 7105394. The 7420, for example, came standard with two of these "Thebe" cards for connecting to the disk trays. Two Thebe cards could handle up to 12 trays, so one would add two more cards to go to 24 trays, or have up to six Thebe cards to handle 36 trays. This card was for external SAS only. It did not connect to the internal OS drives or the Readzillas, both of which used the internal SCSI controller of the server. These Riverwalk 2 trays ARE supported with AK8. You can upgrade your older 7420 or 7320, no problem, as-is. The much older Riverwalk 1 trays or J4400 trays are NOT supported by AK8. However, they were only used by the 7x10 series, and we already said that the 7x10 series was not supported. Here's where it gets tricky. Since last January, we have been selling the new style disk trays. We call them the "DE2-24P" and the "DE2-24C" trays. The "C" tray is for capacity drives, which are 3.5" 3TB or 4TB drives. The "P" trays are for performance drives, which are 2.5" 300GB and 900GB drives. These trays are NOT Riverwalk 2 trays, even though the "C" series may kind of look like it. Different manufacturer and different firmware. They are not new. Like I said, we've been selling them with the 7x20 series since last January. They are the only disk trays we will be selling going forward. Of course, AK8 supports them. So what's the problem? The problem is going to be for people who have to mix drive trays. Remember, your older 7x20 series has Thebe SAS2 HBAs. These have 2 SAS ports per card.  The new ZS3-2 and ZS3-4 systems, however, have the new "Thebe2" SAS2 HBAs. These Thebe2 cards have 4 ports per card. This is very cool, as we can now do more SAS channels with less cards. Instead of needing 4 SAS cards to grow to 24 trays like we did with the old Thebe cards, I can now do 24 trays with only 2 Thebe2 cards. This means more IO slots for fun things like Infiniband and 10G. So far, so good, right? These Thebe2 cards work with any disk tray. You can even mix older DS2 trays with the newer DE2 trays in the same system, as long as you have Thebe2 cards. Ah, there's your problem. You don't have Thebe2 cards in your old 7420, do you? Well, I told you the bad news wasn't that bad, right? We can take out your Thebe cards and replace them with Thebe2. You can then plug your older DS2 trays right back in, and also now get newer DE2 trays going forward. However, it's important that the trays are on different SAS channels. You can mix them in the same system, but not on the same channel. Ask your local SC if you need help with the new cable layout. By the way, the new ZS3-2 and ZS3-4 systems also include a new IO card called "Erie" cards. These are for INTERNAL SAS to the OS drives and the Readzillas. So those are now SAS2 instead of SATA like the older models. Yes, the Erie card uses an IO slot, but that's OK, because the Thebe2 cards allow us to use less SAS HBAs to grow the system, right? That's it. Not too much bad news and really not that bad. AK8 does not support the 7x10 series, and you may need new Thebe2 cards in your older systems if you want to add on newer DE2 trays. I think we can all agree that there are worse things out there. Like our Congress.   Next up.... More good news and cool AK8 tricks. Such as virtual NICS. 

    Read the article

  • Using all Ten IO slots on a 7420

    - by user12620172
    So I had the opportunity recently to actually use up all ten slots in a clustered 7420 system. This actually uses 20 slots, or 22 if you count the clusteron card. I thought it was interesting enough to share here. This is at one of my clients here in southern California. You can see the picture below. We have four SAS HBAs instead of the usual two. This is becuase we wanted to split up the back-end taffic for different workloads. We have a set of disk trays coming from two SAS cards for nothing but Exadata backups. Then, we have a different set of disk trays coming off of the other two SAS cards for non-Exadata workloads, such as regular user file storage. We have 2 Infiniband cards which allow us to do a full mesh directly into the back of the nearby, production Exadata, specifically for fast backups and restores over IB. You can see a 3rd IB card here, which is going to be connected to a non-production Exadata for slower backups and restores from it.The 10Gig card is for client connectivity, allowing other, non-Exadata Oracle databases to make use of the many snapshots and clones that can now be created using the RMAN copies from the original production database coming off the Exadata. This allows for a good number of test and development Oracle databases to use these clones without effecting performance of the Exadata at all.We also have a couple FC HBAs, both for NDMP backups to an Oracle/StorageTek tape library and also for FC clients to come in and use some storage on the 7420.  Now, if you are adding more cards to your 7420, be aware of which cards you can place in which slots. See the bottom graphic just below the photo.  Note that the slots are numbered 0-4 for the first 5 cards, then the "C" slots which is the dedicated Cluster card (called the Clustron), and then another 5 slots numbered 5-9. Some rules for the slots: Slots 1 & 8 are automatically populated with the two default SAS cards. The only other slots you can add SAS cards to are 2 & 7. Slots 0 and 9 can only hold FC cards. Nothing else. So if you have four SAS cards, you are now down to only four more slots for your 10Gig and IB cards. Be sure not to waste one of these slots on a FC card, which can go into 0 or 9, instead.  If at all possible, slots should be populated in this order: 9, 0, 7, 2, 6, 3, 5, 4

    Read the article

  • Does any Certificate Authority support both SAN and wildcards?

    - by nicholas a. evans
    My basic quandry is that wildcard certificates don't support subdomains of subdomains, nor do they help with alternate domain names. Basically, if my CN is example.com, I want a Subject Alternative Name field that looks roughly like so: DNS:example.com DNS*.example.com DNS:*.beta.example.com DNS:example.net DNS:*.example.net DNS:*.beta.example.net Using a self-signed cert, I verified that the browsers will work just fine with this. Unfortunately, none of the Certificate Authorities that I looked into (Thawte, GoDaddy, Verisign, Digicert) seemed to support both wildcard certs and Subject Alternative Name (sometimes referred to as "Multiple Domain UCC"). I even called up GoDaddy tech support to confirm. Is there a CA (trusted by 99% of browsers) that supports wildcards for the Subject Alternative Name? One little restriction: I'm saddled with Amazon EC2's single Elastic IP per instance limitation. Here are what I see as my backup plans: set up three extra EC2 instances, each configured for a different IP address and cert, and nginx reverse proxy from three of them into the app server(s) introduces latency(?), and even the cheapest EC2 instance isn't that cheap instead of dedicated reverse proxy instances, setup the four or more almost identical EC2 app servers, with nginx using the port to determine which cert to deliver, and use haproxy to distribute the traffic amongst themselves. complicated to configure and manage? I'm not using the cheapest EC2 instance type for my app servers. If I don't need 4+ app servers for the load, it raises the cost. set up an external server (outside of EC2) that doesn't have EC2's Elastic IP address restrictions, setup all of the alternate IP addresses and certificates on that server, and nginx reverse proxy from that server into the EC2 app servers. extra IP addresses are almost free (still need to pay for the server of course), but don't come with the robust "elasticity" that Amazon's Elastic IPs provide. even more latency than in the first scenario. Are these approaches crazy or reasonable? Do you have another one to suggest?

    Read the article

  • how to initialize two logical drives on a HP P400i controller without reboot

    - by John
    What I am trying to do is initialize two logical drives on a HP P400i embedded controller without a reboot of the system here my current Array config: array A (SAS, Unused Space: 0 MB) logicaldrive 1 (17.9 GB, RAID 5, OK) logicaldrive 2 (17.9 GB, RAID 5, OK) logicaldrive 3 (75.9 GB, RAID 5, OK) logicaldrive 4 (25.0 GB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 5 (99 MB, RAID 0, OK) logicaldrive 6 (68.2 GB, RAID 0, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK) windows 2003 machine running the HpCISs2.sys driver version 6.20.0.32 . I have the ACU and ACU CLI tools installed version 8.28.13.0, P400i firmware version 2.74 . Now what I'd like to do is removes the physical drive 1I:1:4 and delete the two logical drives in array B. then insert a new drive in to bay 4 that contains two new logical drives and have them show up in array B again. So far after I remove the drive and delete the failed logical drives, I insert the new drive and run HPacucli rescan. I get the new drive to show up as unassinged physical drive but I cant figure out now to "for lack of a better word" mount the 2 logical drives on the new unassinged disk. If I reboot the system the array controller picks up the new fourth drive and creates Array B with the drives without problem but I'd really like to not have to reboot the server. Any ideas?

    Read the article

  • Windows iScsi software initiator automatic reconnect

    - by mamu
    I am using sofware iscsi initiator in windows server 2008 r2 to connect to a san. Everything works fine. But issue is if at time of boot san is not available it's not adding drives. It stays in reconnecting status when san is available. I have to manually disconnect and connect to get it working. How can i make it automatically connect when san is available.

    Read the article

  • Energy Dashboard Web Portal

    UC San Diego researchers launch an Internet portal to showcase the real-time measurement and visualization of energy use on the campus University of California-San Diego - United States - SAN DIEGO - California - Counties

    Read the article

  • How to use iSCSI inside HyperV VM?

    - by William
    I have 2 Dell R710 servers (intended to set up HyperV cluster) and a MD3000i SAN set up: Server1/Server2: NIC 1: connected to company LAN NIC 2: crossover to the other server's NIC 2 NIC 3: crossover to iSCSI port of SAN controller 1 NIC 4: crossover to iSCSI port of SAN controller 2 I have both servers setup as diskless servers with iSCSI boot from SAN without problem. But how can I access iSCSI from within the VM such that I can set up clustering inbetween the VMs? I can ping from the host to the SAN but found that NIC3/4 cannot be used for virtual network in HyperV? What am I doing wrong?

    Read the article

  • LSI RAID-on-chip with RAID6 over two SAS links goes red when HDD enclosure is powered cycled; how to recover?

    - by GregC
    I have a RAID6 array managed by LSI 9286-8e card. I also have Sans Digital 24-bay NexentaSTOR JBOD enclosure with SAS extender built-in. They are connected to separate UPS devices. Normally, I'd shut down the PC, leaving RAID6 in healthy state. But today the power to JBOD enclosure was cut but PC kept running. After restarting the PC, all disks in RAID6 have lit up RED, and the only option in LSI MegaRAID manager app was to reset each disk to unassigned, thereby loosing all data on RAID6 array. Thankfully, I am only testing, but how would I recover if this were to happen in production?

    Read the article

  • How to begin writing an Application Server over Apache?

    - by Cracker
    For my college project, I want to create a simple application server in C that runs over Apache. Like .php, .asp, .jsp, the extension of my files would be .sas. I have already written a parser which reads the .sas files and generates the output. For example, consider a file index.sas with the below code: <% echo "Hello"; %> Now, if I execute: sas index.sas The result would be: Hello Now I want to use this program as an application server over Apache just as PHP, Tomcat, etc. work over Apache. I have heard of cgi-bin but I think PHP uses a different approach. I want to learn the approach which PHP uses. Please advice.

    Read the article

  • Flash Player, security: If a URL starts with "http://" will the SWF always be loaded into REMOTE san

    - by Pavel
    Seems to be a question for a Flash security guru. Suppose we are loading an external SWF movie with MovieClipLoader.loadMovie(url:String) Is it safe to assume that if url starts with "http://", the movie will be loaded in REMOTE sandbox? We need to tell local SWFs from remote ones to close a security hole. If you need the context read on. We have developed a Projector, written in C++ embedding Flash Player ActiveX. Our Flash application runs inside the Projector. Soon we want to give our users a way to create plugins for the application. The plugins are obviously will be SWF movies. The case I'm afraid of is the following. A bad person creates a malicious evil.swf pretending it to be nice plugin for our app. In case evil.swf is loaded from the local file system it is granted an access to the whole MovieClip tree and Projector API, opening C++ file access operations. On the other hand if evil.swf is loaded from the internet, remotely, it will be locked in REMOTE sandbox by Flash security model. Because of this, we need a reliable way to tell local SWF from remote one before loading it. And we must not make a mistake. So again, is it safe to assume that if url begins with "http://", the clip will be loaded inside REMOTE sandbox?

    Read the article

  • Ubuntu doesn't detect drives conected to LSI "Host Bus Adapter"

    - by dvrecmfo
    I purchased LSI SAS 9300-4i Host Bus Adapter, from card bios I can see that it detected all hard drives connected to it, but from ubuntu I can't see them. What I've tried: Installed the driver provided here http://www.lsi.com/products/host-bus-adapters/pages/lsi-sas-9300-4i.aspx#tab/tab3 (I tried both LINUX_RH_SL_OEL_CTX_MPT_GEN3_C0_Phase2.0-3.00.00.00-1 and Linux_Driver_RHEL5-6_SLES10-11_P1) lspci | grep -i lsi 07:00.0 Serial Attached SCSI controller: LSI Logic / Symbios Logic SAS3004 PCI-Express Fusion-MPT SAS-3 (rev 02)

    Read the article

  • Is it possible to shrink the size of an HP Smart Array logical drive?

    - by ewwhite
    I know extension is quite possible using the hpacucli utility, but is there an easy way to reduce the size of an existing logical drive (not array)? The controller is a P410i in a ProLiant DL360 G6 server. I'd like to reduce logicaldrive 1 from 72GB to 40GB. => ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438006FD9A50 Cache Serial Number: PAAVP9VYFB8Y RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 3.66 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 512 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 412476 MB Status: OK Logical Drive: 1 Size: 72.0 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 18504 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001C132E4BBDFAA6DAD13DA3 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 196 MB, / 12.0 GB, /usr 8.0 GB, /var 4.0 GB, /tmp 2.0 GB OS Status: LOCKED Logical Drive Label: AE438D6A5001438006FD9A50BE0A Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 Device Number: 250 Firmware Version: RevC WWID: 5001438006FD9A5F Vendor ID: PMCSIERA Model: SRC 8x6G

    Read the article

< Previous Page | 11 12 13 14 15 16 17 18 19 20 21 22  | Next Page >