  • Next Quarterly Customer Update Webcast is Nov 27th (Nov 28th in Asia Pacific)

    - by John Klinke
    Join the WebCenter team as we present the latest product direction that was recently shared at the Oracle OpenWorld conference in San Francisco last month.   This Oracle WebCenter Quarterly Customer Update Webcast is scheduled on Nov 27th (Nov 28th in Asia Pacific). We will also be sharing the latest product updates and key support announcements that all WebCenter professionals and solution owners need to know. Don’t miss out on getting the latest information.  There will be two live sessions with Q&A at the end of each session.   Register for Session 1 -  Nov 27th at 9am San Francisco, 12pm New York, and 5pm London Register for Session 2 – Nov 28th at 9am Singapore, 11am Sydney, and 6pm (Nov 27th) San Francisco

    Read the article

  • WebCenter Customer Webcast - Nov 27th/28th

    - by Kellsey Ruppel
    WebCenter Customer Webcast - Nov 27th/28th Join the Oracle WebCenter team on this all important webcast as we present the latest product direction that was recently shared at the Oracle OpenWorld 2012 conference in San Francisco, CA. This next Oracle WebCenter Quarterly Customer Update Webcast is scheduled to air on Nov 27th (Nov 28th in Asia Pacific). We will also be sharing the latest product updates and key support announcements that all Oracle WebCenter professionals and solution owners need to know. Don’t miss out on getting the latest information! There will be two live sessions with Q&A at the end of each session. Register for Session 1 -  Nov 27th 9am San Francisco, 12pm New York, 5 pm London Register for Session 2 – Nov 28thth 9am Singapore, 11am Sydney, (27th) 6pm San Francisco

    Read the article

  • How to reliably map vSphere disks <-> Linux devices

    - by brianmcgee
    Task at hand After a virtual disk has been added to a Linux VM on vSphere 5, we need to identify the disks in order to automate the LVM storage provision. The virtual disks may reside on different datastores (e.g. sas or flash) and although they may be of the same size, their speed may vary. So I need a method to map the vSphere disks to Linux devices. Ideas Through the vSphere API, I am able to get the device info: Data Object Type: VirtualDiskFlatVer2BackingInfo Parent Managed Object ID: vm-230 Property Path: config.hardware.device[2000].backing Properties Name Type Value ChangeId string Unset contentId string "d58ec8c12486ea55c6f6d913642e1801" datastore ManagedObjectReference:Datastore datastore-216 (W5-CFAS012-Hybrid-CL20-004) deltaDiskFormat string "redoLogFormat" deltaGrainSize int Unset digestEnabled boolean false diskMode string "persistent" dynamicProperty DynamicProperty[] Unset dynamicType string Unset eagerlyScrub boolean Unset fileName string "[W5-CFAS012-Hybrid-CL20-004] l****9-000001.vmdk" parent VirtualDiskFlatVer2BackingInfo parent split boolean false thinProvisioned boolean false uuid string "6000C295-ab45-704e-9497-b25d2ba8dc00" writeThrough boolean false And on Linux I may read the uuid strings: [root@lx***** ~]# lsscsi -t [1:0:0:0] cd/dvd ata: /dev/sr0 [2:0:0:0] disk sas:0x5000c295ab45704e /dev/sda [3:0:0:0] disk sas:0x5000c2932dfa693f /dev/sdb [3:0:1:0] disk sas:0x5000c29dcd64314a /dev/sdc As you can see, the uuid string of disk /dev/sda looks somehow familiar to the string that is visible in the VMware API. Only the first hex digit is different (5 vs. 6) and it is only present to the third hyphen. So this looks promising... Alternative idea Select disks by controller. But is it reliable that the ascending SCSI Id also matches the next vSphere virtual disk? What happens if I add another DVD-ROM drive / USB Thumb drive? This will probably introduce new SCSI devices in between. Thats the cause why I think I will discard this idea. Questions Does someone know an easier method to map vSphere disks and Linux devices? Can someone explain the differences in the uuid strings? (I think this has something to do with SAS adressing initiator and target... WWN like...) May I reliably map devices by using those uuid strings? How about SCSI virtual disks? There is no uuid visible then... This task seems to be so obvious. Why doesn't Vmware think about this and simply add a way to query the disk mapping via Vmware Tools?

    Read the article

  • Add Email addressCollection to, cc, bcc and replytoList

    - by san
    i want to add MailAddressCollection with to,cc,bcc and replytolist of my MailMessage(Net.Mail) my code Like MessageEntity.To.Add(GetMailAddress(TOEmailAddress)); MessageEntity.CC.Add(GetMailAddress(CCEmailAddress)); MessageEntity.Bcc.Add(GetMailAddress(BCCEmailAddress)); MessageEntity.RepltToList.Add(GetMailAddress(ReplyEmailAddress)); private static MailAddressCollection GetMailAddress(List<string> LstMailAddress) { MailAddressCollection MAddressCollection = new MailAddressCollection(); if (MailAddress != null) { foreach (string EmailAddress in MailAddress) { if (IsValidEmailId(EmailAddress)) { MAddressCollection.Add((new MailAddress(EmailAddress))); } } } return MAddressCollection; } It is showing the error cannot convert from 'System.Net.Mail.MailAddressCollection' to 'string' Is it possible to add the EmailAddressCollection to email's to/cc/bcc/ReplyToList? Thanks San

    Read the article

  • ZFS - Impact of L2ARC cache device failure (Nexenta)

    - by ewwhite
    I have an HP ProLiant DL380 G7 server running as a NexentaStor storage unit. The server has 36GB RAM, 2 LSI 9211-8i SAS controllers (no SAS expanders), 2 SAS system drives, 12 SAS data drives, a hot-spare disk, an Intel X25-M L2ARC cache and a DDRdrive PCI ZIL accelerator. This system serves NFS to multiple VMWare hosts. I also have about 90-100GB of deduplicated data on the array. I've had two incidents where performance tanked suddenly, leaving the VM guests and Nexenta SSH/Web consoles inaccessible and requiring a full reboot of the array to restore functionality. In both cases, it was the Intel X-25M L2ARC SSD that failed or was "offlined". NexentaStor failed to alert me on the cache failure, however the general ZFS FMA alert was visible on the (unresponsive) console screen. The zpool status output showed: pool: vol1 state: ONLINE scan: scrub repaired 0 in 0h57m with 0 errors on Sat May 21 05:57:27 2011 config: NAME STATE READ WRITE CKSUM vol1 ONLINE 0 0 0 mirror-0 ONLINE 0 0 0 c8t5000C50031B94409d0 ONLINE 0 0 0 c9t5000C50031BBFE25d0 ONLINE 0 0 0 mirror-1 ONLINE 0 0 0 c10t5000C50031D158FDd0 ONLINE 0 0 0 c11t5000C5002C823045d0 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 c12t5000C50031D91AD1d0 ONLINE 0 0 0 c2t5000C50031D911B9d0 ONLINE 0 0 0 mirror-3 ONLINE 0 0 0 c13t5000C50031BC293Dd0 ONLINE 0 0 0 c14t5000C50031BD208Dd0 ONLINE 0 0 0 mirror-4 ONLINE 0 0 0 c15t5000C50031BBF6F5d0 ONLINE 0 0 0 c16t5000C50031D8CFADd0 ONLINE 0 0 0 mirror-5 ONLINE 0 0 0 c17t5000C50031BC0E01d0 ONLINE 0 0 0 c18t5000C5002C7CCE41d0 ONLINE 0 0 0 logs c19t0d0 ONLINE 0 0 0 cache c6t5001517959467B45d0 FAULTED 2 542 0 too many errors spares c7t5000C50031CB43D9d0 AVAIL errors: No known data errors This did not trigger any alerts from within Nexenta. I was under the impression that an L2ARC failure would not impact the system. But in this case, it surely was the culprit. I've never seen any recommendations to RAID L2ARC. Removing the bad SSD entirely from the server got me back running, but I'm concerned about the impact of the device failure (and maybe the lack of notification from NexentaStor as well). Edit - What's the current best-choice SSD for L2ARC cache applications these days?

    Read the article

  • Finding out why Dell Controler is Degraded

    - by Kyle Brandt
    I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState: [root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up. A walk of the entire storage management tree for on of them: StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

    Read the article

  • How does Linux determine the SCSI address of a disk?

    - by Chris Sears
    Greetings, I'm working with RHEL 5.5 guest VMs under VMware ESX 4. When I configure the virtual disks in the VM hardware settings, each disk has a SCSI address in the format "N:M". For example, "1:3" would mean SCSI host number 1 and SCSI target ID 3. When I look at the disk info from the VM's BIOS or a Windows OS, the detected SCSI address info matches up with the virtual hardware settings. But under Linux, the SCSI address components don't match up, at least not completely or consistently. I've tried the three supported virtual SCSI and SAS drivers and they all seem to be "broken", but in different ways. Here's a list of the virtual hardware addresses vs what was detected under Linux with each of the drivers: Driver vHW Addr Linux Addr -------- -------- ---------- LSI SAS 0:0 0:0 LSI SAS 0:3 0:1 LSI SAS 0:6 0:2 LSI SCSI 1:1 2:1 LSI SCSI 1:4 2:4 LSI SCSI 1:7 2:7 pvSCSI 2:2 1:2 pvSCSI 2:5 1:5 pvSCSI 2:8 1:8 My main question is why does this happen under Linux? The next question is: how do I get it fixed or fix it myself? If I was going to guess, I'd say it's an issue with how the kernel is handing out the SCSI host number and how the Linux SCSI driver (included with VMware tools) is detecting the SCSI target number. Perhaps the order the drivers are loaded also has something to do with the issue. I'm guessing this would not involve udev, but I could be wrong. Any thoughts would be appreciated. Thanks! PS. My environment is VMware, but I don't need an answer for these drivers specifically. I imagine this might be a problem with any SCSI driver under Linux.

    Read the article

  • jQuery Autocomplete problem - Shift Key behaves same as Return Key

    - by user237005
    See: http://www.airbnb.com/ In the search bar, start typing "san f" (no quotes, all lowercase), then hit Return (or Enter). "San Francisco" is autocompleted. This is good! Now clear the search field and start over. type "San F" and boom - "San Francisco" is autocompleted as soon as you hit Shift. This is not expected. This happens in FF & Safari, but is untested elsewhere. I've looked through the jQuery Autocomplete Source Code and everything looks normal. Has anyone experienced this before?

    Read the article

  • Refresh Service List of a paired Bluetooth device !

    - by sas-san
    Hi- Is there any possibility to refresh the service list of a paired device in a programm? At the moment, i have to go to the bluetooth options and select the device properties of the bluetooth device and have to refresh the service list manually. Is there any API that RIMM provides to do programmatically? thanks,

    Read the article

  • Dell Poweredge R410 replace PERC S100 with PERC 6i

    - by Robe Eleckers
    I want to replace the PERC S100 RAID Controller with a PERC6i to be able to use 4 SAS harddrives instead of only SATA drives. What exactly do I need for this, what I've got so far: PERC6i PCIe x8 card. 4 x SAS 300GB 15000rpm drives Some questions I have Do I need a different backplane to accomodate the SAS disks? If so, what kind of backplane? Do I need a special cable to hookup the PERC6i with the backplane? If so, what kind of cable? Thanks.

    Read the article

  • Dell OpenManage Causing Periodic Slowness

    - by Zorlack
    Today we diagnosed the cause of a Periodic slowness issue: see here. Dell OpenManage Server Administrator seems to have been causing hourly slowness. It would occasionally peg one of the CPUs for upwards of two minutes. Disabling it drastically improved the performance of the SQL Server. The server hardware: Dell R710 Dual Quad Core 2.9GHz Processors 96GB Memory 2 Disk RAID 1 SAS System Disk (Internal) 4 Disk RAID 10 SAS Log Disk (Internal) 14 Disk RAID 10 SAS Data Disk (External DAS MD1000) Windows 2008 Enterprise R2 x64 We installed the OS using Dell OpenManage Server Assistant, so I assume that it was correctly configured. For now we have disabled OMSA to alleviate the performance issues it was causing, but I'd like to be able to re-enable it. Has anyone had a similar experience that can shed a little light on the nature of this problem?

    Read the article

  • Database Security Events in April

    - by Troy Kitch
    Wed, Apr 18, Executive Oracle Database Security Round Table - Tampa, FL Tue, Apr 24, ISC(2) Leadership Regional Event Series - San Diego, CA April 24 - May 17,  Independent Oracle Users Group Enterprise Data at Risk Seminar Series Tue, Apr 24 IOUG Enterprise Data at Risk Seminar Series - Toronto Wed, Apr 25 IOUG Enterprise Data at Risk Seminar Series - New York Thu, Apr 26 IOUG Enterprise Data at Risk Seminar Series - Boston Thu, Apr 26 ISC(2) Leadership Regional Event Series - San Jose, CA

    Read the article

  • Zero-channel RAID for High Performance MySQL Server (IBM ServeRAID 8k) : Any Experience/Recommendati

    - by prs563
    We are getting this IBM rack mount server and it has this IBM ServeRAID8k storage controller with Zero-Channel RAID and 256MB battery backed cache. It can support RAID 10 which we need for our high performance MySQL server which will have 4 x 15000K RPM 300GB SAS HDD. This is mission-critical and we want as much bandwidth and performance. Is this a good card or should we replace with another IBM RAID card? IBM ServeRAID 8k SAS Controller option provides 256 MB of battery backed 533 MHz DDR2 standard power memory in a fixed mounting arrangement. The device attaches directly to IBM planar which can provide full RAID capability. Manufacturer IBM Manufacturer Part # 25R8064 Cost Central Item # 10025907 Product Description IBM ServeRAID 8k SAS - Storage controller (zero-channel RAID) - RAID 0, 1, 5, 6, 10, 1E Device Type Storage controller (zero-channel RAID) - plug-in module Buffer Size 256 MB Supported Devices Disk array (RAID) Max Storage Devices Qty 8 RAID Level RAID 0, RAID 1, RAID 5, RAID 6, RAID 10, RAID 1E Manufacturer Warranty 1 year warranty

    Read the article

  • Libgdx actor bounds are wrong

    - by Undume
    The Actor's boundaries are not centered at the ButtonText but I used the setBounds() method. The higher the Y position is, the less centered is the boundary. The weird thing is that i only created and added to the Stage one button but the screen shows two. When i click the top button, the bottom one is the one highlighted. How can i fix that? import com.badlogic.gdx.Game; import com.badlogic.gdx.Gdx; import com.badlogic.gdx.files.FileHandle; import com.badlogic.gdx.scenes.scene2d.Stage; import com.badlogic.gdx.scenes.scene2d.ui.Skin; import com.badlogic.gdx.scenes.scene2d.ui.TextButton; public class MyGame extends Game { Stage stage; @Override public void create() { stage=new Stage(); FileHandle skinFile = new FileHandle("data/resources/uiskin/uiskin.json"); Skin skin = new Skin(skinFile); TextButton sas=new TextButton("dd",skin); sas.setBounds(0, 500, 100, 100); stage.addActor(sas); Gdx.input.setInputProcessor(stage); } @Override public void dispose() { super.dispose(); } @Override public void render() { super.render(); stage.act(Gdx.graphics.getDeltaTime()); stage.draw(); } @Override public void resize(int width, int height) { super.resize(width, height); } @Override public void pause() { super.pause(); } @Override public void resume() { super.resume(); } }

    Read the article

  • S.M.A.R.T - Predictive Failure Count

    - by Bastien974
    I'm monitoring my IBM ServeRAID M5015 controller for RAID status with MegaCLI, I have this on one of the disk : Enclosure Device ID: 252 Slot Number: 6 Enclosure position: 0 Device Id: 14 Sequence Number: 2 Media Error Count: 32 Other Error Count: 0 Predictive Failure Count: 18 Last Predictive Failure Event Seq Number: 8119 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.464 GB [0x22cee000 Sectors] Firmware state: Online, Spun Up SAS Address(0): 0x5000c50042c319c9 SAS Address(1): 0x0 Connected Port Number: 5(path0) Inquiry Data: IBM-ESXSST9300653SS B6336XN04HC10525B633 IBM FRU/CRU: 81Y9671 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :33 Celsius What does this mean exactly ? I can't find an exact description, is there a way to have more details ? The RAID array has the Optimal state. Media Error Count: 32 Predictive Failure Count: 18 Is there a way through the CLI to power-on the front LED so I physically know which disk I need to replace ?

    Read the article

  • Zero-channel RAID for High Performance MySQL Server (IBM ServeRAID 8k) : Any Experience/Recommendation?

    - by prs563
    We are getting this IBM rack mount server and it has this IBM ServeRAID8k storage controller with Zero-Channel RAID and 256MB battery backed cache. It can support RAID 10 which we need for our high performance MySQL server which will have 4 x 15000K RPM 300GB SAS HDD. This is mission-critical and we want as much bandwidth and performance. Is this a good card or should we replace with another IBM RAID card? IBM ServeRAID 8k SAS Controller option provides 256 MB of battery backed 533 MHz DDR2 standard power memory in a fixed mounting arrangement. The device attaches directly to IBM planar which can provide full RAID capability. Manufacturer IBM Manufacturer Part # 25R8064 Cost Central Item # 10025907 Product Description IBM ServeRAID 8k SAS - Storage controller (zero-channel RAID) - RAID 0, 1, 5, 6, 10, 1E Device Type Storage controller (zero-channel RAID) - plug-in module Buffer Size 256 MB Supported Devices Disk array (RAID) Max Storage Devices Qty 8 RAID Level RAID 0, RAID 1, RAID 5, RAID 6, RAID 10, RAID 1E Manufacturer Warranty 1 year warranty

    Read the article

  • Special Reminder for Oracle OpenWorld Attendees: Oracle Account Credentials

    - by Bob Rhubart
    A special reminder from the event organizers for those attending Oracle OpenWorld: "Please make sure you have your Oracle.com account log in details with you when you arrive onsite in San Francisco. This is the username and password you used/created for your Oracle OpenWorld San Francisco 2012 registration. These details will be required to check-in and receive your badge as well as to gain access to My Account and Schedule Builder onsite at the event."

    Read the article

  • Oracle OpenWorld Preview

    Learn. Develop. Explore. Here’s a sneak peak at Oracle OpenWorld San Francisco, which offers hundreds of learning opportunities, special programs, and networking events. Make plans to be in San Francisco October 11 through 14.

    Read the article

  • Oracle OpenWorld Preview

    Learn. Develop. Explore. Here’s a sneak peak at Oracle OpenWorld San Francisco, which offers hundreds of learning opportunities, special programs, and networking events. Make plans to be in San Francisco October 11 through 14.

    Read the article

  • Oracle OpenWorld Preview

    Learn. Develop. Explore. Here’s a sneak peak at Oracle OpenWorld San Francisco, which offers hundreds of learning opportunities, special programs, and networking events. Make plans to be in San Francisco October 11 through 14.

    Read the article

  • Reminder: JavaOne Call For Papers Closing April 9th, 11:59pm

    - by arungupta
    JavaOne 2012 Call For Papers is closing on April 9th. Make sure to get your submissions in time and make the reviewers job exciting. Submit now! Read tips for paper submission here and an insight into the review process and more tips here. The conference will be held in San Francisco from September 30th to October 4th, 2012. And between now and this JavaOne in San Francisco, the conference is also going to Japan, Russia, and India.

    Read the article

  • Server drives: 2.5" SCSI less reliable than 3.5" ?

    - by Bill
    Just had an HP 2.5" SAS 10k drive fail on a RAID5 array after about 2.5 years. It made me wonder if this was a fluke or an indication that 2.5" drives are less reliable than 3.5" SAS drives. I've had many 3.5" SAS drives running for many years without any issues (knock on wood). I would think that smaller drives would generate less heat and therefore be more reliable, but couldn't find any evidence of this. I realize all drives will eventually fail and that it's a crap shoot with any particular model, but was hoping someone could point out some related studies or comment on the SCSI drive sizes they've found to be most reliable in servers. Thanks.

    Read the article

  • Firewall for internal networks

    - by Cylindric
    I have a virtualised infrastructure here, with separated networks (some physically, some just by VLAN) for iSCSI traffic, VMware management traffic, production traffic, etc. The recommendations are of course to not allow access from the LAN to the iSCSI network for example, for obvious security and performance reasons, and same between DMZ/LAN, etc. The problem I have is that in reality, some services do need access across the networks from time to time: System monitoring server needs to see the ESX hosts and the SAN for SNMP VSphere guest console access needs direct access to the ESX host the VM is running on VMware Converter wants access to the ESX host the VM will be created on The SAN email notification system wants access to our mail server Rather than wildly opening up the entire network, I'd like to place a firewall spanning these networks, so I can allow just the access required For example: SAN SMTP Server for email Management SAN for monitoring via SNMP Management ESX for monitoring via SNMP Target Server ESX for VMConverter Can someone recommend a free firewall that will allow this kind of thing without too much low-level tinkering of config files? I've used products such as IPcop before, and it seems to be possible to achieve this using that product if I re-purpose their ideas of "WAN", "WLAN" (the red/green/orange/blue interfaces), but was wondering if there were any other accepted products for this sort of thing. Thanks.

    Read the article

  • The enterprise vendor con - connecting SSD's using SATA 2 (3Gbits) thus limiting there performance

    - by tonyrogerson
    When comparing SSD against Hard drive performance it really makes me cross when folk think comparing an array of SSD running on 3GBits/sec to hard drives running on 6GBits/second is somehow valid. In a paper from DELL (http://www.dell.com/downloads/global/products/pvaul/en/PowerEdge-PowerVaultH800-CacheCade-final.pdf) on increasing database performance using the DELL PERC H800 with Solid State Drives they compare four SSD drives connected at 3Gbits/sec against ten 10Krpm drives connected at 6Gbits [Tony slaps forehead while shouting DOH!]. It is true in the case of hard drives it probably doesn’t make much difference 3Gbit or 6Gbit because SAS and SATA are both end to end protocols rather than shared bus architecture like SCSI, so the hard drive doesn’t share bandwidth and probably can’t get near the 600MiBytes/second throughput that 6Gbit gives unless you are doing contiguous reads, in my own tests on a single 15Krpm SAS disk using IOMeter (8 worker threads, queue depth of 16 with a stripe size of 64KiB, an 8KiB transfer size on a drive formatted with an allocation size of 8KiB for a 100% sequential read test) I only get 347MiBytes per second sustained throughput at an average latency of 2.87ms per IO equating to 44.5K IOps, ok, if that was 3GBits it would be less – around 280MiBytes per second, oh, but wait a minute [...fingers tap desk] You’ll struggle to find in the commodity space an SSD that doesn’t have the SATA 3 (6GBits) interface, SSD’s are fast not only low latency and high IOps but they also offer a very large sustained transfer rate, consider the OCZ Agility 3 it so happens that in my masters dissertation I did the same test but on a difference box, I got 374MiBytes per second at an average latency of 2.67ms per IO equating to 47.9K IOps – cost of an 240GB Agility 3 is £174.24 (http://www.scan.co.uk/products/240gb-ocz-agility-3-ssd-25-sata-6gb-s-sandforce-2281-read-525mb-s-write-500mb-s-85k-iops), but that same drive set in a box connected with SATA 2 (3Gbits) would only yield around 280MiBytes per second thus losing almost 100MiBytes per second throughput and a ton of IOps too. So why the hell are “enterprise” vendors still only connecting SSD’s at 3GBits? Well, my conspiracy states that they have no interest in you moving to SSD because they’ll lose so much money, the argument that they use SATA 2 doesn’t wash, SATA 3 has been out for some time now and all the commodity stuff you buy uses it now. Consider the cost, not in terms of price per GB but price per IOps, SSD absolutely thrash Hard Drives on that, it was true that the opposite was also true that Hard Drives thrashed SSD’s on price per GB, but is that true now, I’m not so sure – a 300GByte 2.5” 15Krpm SAS drive costs £329.76 ex VAT (http://www.scan.co.uk/products/300gb-seagate-st9300653ss-savvio-15k3-25-hdd-sas-6gb-s-15000rpm-64mb-cache-27ms) which equates to £1.09 per GB compared to a 480GB OCZ Agility 3 costing £422.10 ex VAT (http://www.scan.co.uk/products/480gb-ocz-agility-3-ssd-25-sata-6gb-s-sandforce-2281-read-525mb-s-write-410mb-s-30k-iops) which equates to £0.88 per GB. Ok, I compared an “enterprise” hard drive with a “commodity” SSD, ok, so things get a little more complicated here, most “enterprise” SSD’s are SLC and most commodity are MLC, SLC gives more performance and wear, I’ll talk about that another day. For now though, don’t get sucked in by vendor marketing, SATA 2 (3Gbit) just doesn’t cut it, SSD need 6Gbit to breath and even that SSD’s are pushing. Alas, SSD’s are connected using SATA so all the controllers I’ve seen thus far from HP and DELL only do SATA 2 – deliberate? Well, I’ll let you decide on that one.

    Read the article

  • MS SQL Query Sum of subquery

    - by San
    Hello , I need a help i getting following output from the query . SELECT ARG_CONSUMER, cast(ARG_TOTALAMT as float)/100 AS 'Total', (SELECT SUM(cast(DAMT as float))/100 FROM DEBT WHERE DDATE >= ARG.ARG_ORIGDATE AND DDATE <= ARG.ARG_LASTPAYDATE AND DTYPE IN ('CSH','CNTP','DDR','NBP') AND DCONSUMER = ARG.ARG_CONSUMER ) AS 'Paid' FROM ARGMASTER ARG WHERE ARG_STATUS = '1' Current output is a list of all records... But what i want to achieve here is count of arg consumers Total of ARG_TOTALAMT total of that subquery PAID difference between PAID & Total amount. I am able to achieve first two i.e. count of consumers & total of ARG _ TOTALAMT... but i am confused about sum of of ...i.e. sum (SELECT SUM(cast(DAMT as float))/100 FROM DEBT WHERE DDATE >= ARG.ARG_ORIGDATE AND DDATE <= ARG.ARG_LASTPAYDATE AND DTYPE IN ('CSH','CNTP','DDR','NBP') AND DCONSUMER = ARG.ARG_CONSUMER) AS 'Paid' Please advice

    Read the article