Search Results

Search found 14757 results on 591 pages for 'switch statement'.

Page 129/591 | < Previous Page | 125 126 127 128 129 130 131 132 133 134 135 136  | Next Page >

  • HP ProCurve & Cisco switches interoperability

    - by Kamil Z
    I have a couple of questions regarding Cisco and HP ProCurve interoperability. Here's a link to pdf with my network topology. Can someone help me with basic VLAN configuration in such topology? Below there are some details of my configuration: # m_management_2 interface FastEthernet0/43 switchport access vlan 250 switchport mode access spanning-tree port-priority 32 spanning-tree cost 100 # MTA2-swmgmt1 vlan 1 name "DEFAULT_VLAN" untagged 1-48 ip address 10.10.249.190 255.255.255.128 exit # MTA2-swtr1 vlan 1 name "DEFAULT_VLAN" untagged 1-14,16-48 no ip address no untagged 15 exit vlan 100 name "MTA Mgmt" untagged 15 ip address 10.10.249.188 255.255.255.128 exit # MTA2-swtr2 vlan 1 name "DEFAULT_VLAN" untagged 1-14,16-48 no ip address no untagged 15 exit vlan 100 name "MTA Mgmt" untagged 15 ip address 10.10.249.189 255.255.255.128 exit I don't post MTA2-bcsw[12] configuration, because I wasn's successfull in this one yet. Every time I configure VLANs on MTA2-bcsw[12] Fa0/24 interface on m_management_2 goes down bacause of receiving tagged BPDUs on access port (there are no VLANs configured on MTA2-swmgmt1 because of fact that only 250 VLAN is allowed in this switch. Is it correct?). Can someone provide me some basic configuration for this topology? Second thing I want to ask is concept of connection from MTA2-swmgmt1 to MTA2-swtr[12] HP switches for the sake of management. How to configure such ports on HP switches (managed switch and manager switch). Is my actual configuration correct?

    Read the article

  • Cisco SG200 vlan issue in ESXi VSA cluster

    - by George
    I have three Cisco SG200-26 switches, and I also have two ESXi hosts that I have connected like shown in the below "best practice" map by VMware: http://communities.vmware.com/servlet/JiveServlet/previewBody/17393-102-1-22458/VSA_networking_map.pdf Even though I created the VLANs in the SG200 and I set the two VLANs (508 and 608) as allowed for these untagged ports (where my ESX NIC's are connected), I can not ping from host 1 to host 2 when configuring the NIC's to use 608 VLAN. Am I missing something? my IP's are all in the 192.168. range, and the only reason I need the VLANs is to isolate the traffic of VSA back-end internally, only the two hosts will be using the VLANs. So I think I do not have to create virtual interfaces on my router since that's the case, is my understanding correct? Also sending my switch config screenshot below.. all 3 switches have the latest firmware (it seems these were originally linksys and got rebranded as cisco after the acquisition) http://img31.imageshack.us/img31/2503/switch.gif Any ideas what to change on the Cisco SG200 to make this work , would be appreciated! The second VLAN (608) only needs two IP's: 192.168.0.1 and 192.168.0.2 The first VLAN (508) will have about 15 IP's for ESXi Management and VSA cluster service, I could use either 192.168.1.xx or 10.0.1.xx The rest of my network (about 50 clients) is in 192.168.1.xx range VMware also states that the VLAN protocol on the physical switch must be 802.1Q, not ISL, anyone knows which of the two my SG200-26 uses? In addition to that, the only requirement from VSA is that my two hosts: -Are in the same subnet. -Have static IP addresses set. -Have the same Default Gateway configured. If I need inter-vlan routing for this, I suppose I have to create virtual interfaces on my sonicwall, and assign an IP for each VLAN, and then set routes between them? Thank you for your time!

    Read the article

  • Use synergy with Physical KVM

    - by Mr. Man
    I am using synergy on a Linux Mint computer as the server with a Mac as the client. I also have a physical KVM switch. The problem I have is that when ever I switch the physical KVM to my Mac, synergy stops working as in the keyboard and mouse don't work with the Mac. Thanks in advance! EDIT: here are some logs: From the Mint machine: INFO: synergys.cpp,1042: Synergy server 1.3.1 on Linux 2.6.31-14-generic #48-Ubuntu SMP Fri Oct 16 14:04:26 UTC 2009 i686 DEBUG: synergys.cpp,1051: opening configuration synergy.conf DEBUG: synergys.cpp,1062: configuration read successfully DEBUG: CXWindowsScreen.cpp,847: XOpenDisplay(:0.0) DEBUG: CXWindowsScreenSaver.cpp,339: xscreensaver window: 0x00000000 DEBUG: CXWindowsScreen.cpp,117: screen shape: 0,0 1024x768 DEBUG: CXWindowsScreen.cpp,118: window is 0x03800004 DEBUG: CScreen.cpp,38: opened display DEBUG: CXWindowsScreen.cpp,679: registered hotkey F12 (id=efc9 mask=0000) as id=1 NOTE: synergys.cpp,500: started server INFO: CServer.cpp,1141: screen ubuntu shape changed NOTE: CClientListener.cpp,127: accepted client connection DEBUG: CClientProxy1_0.cpp,404: received client marks-mac.local info shape=-1024,0 2304x800 NOTE: CServer.cpp,278: client mac has connected INFO: CServer.cpp,447: switch from ubuntu to mac at -1024,393 INFO: CScreen.cpp,116: leaving screen DEBUG: CXWindowsClipboard.cDEBUG: CXWindowsClipboard.cDEBUG: CXWindowsClipboard.cDEBUG: CXWindowsClipboard.cDEBUG: CXWindowsClipboard.cDEBUG: CXWinavDEBUG: CXWindowsClipboard.cDEBUG: CXWindowsClipboard.cDEBUG302)DEBUG: CXWindowsClipboard.cDEBUG: CXWindowsClipboard.cDE47DEBUG: CXWindowsClipboard.cDEBUG: CXWindowsrset=utf-8 (633), text/plain (462) DEBUG: CXWindowsClipboard.cpp,555: added fDEBUG: CXWindowsClipboard.cpp,555: added f DEBUG: CXWindCXWDEBUG: CXWindowsClipboard.cpp,555: added fDEBUG:SerDEBUG: CXWindowsClipboard.cpp,555: ed DEBUG: CXWindowsClipboard.cpp,555: added fDEBUG: CXWindowsClipboard.cpp,555owsClDEBUG: CXWindowsClipboard.cpp,555: 1DEBUG: CXWindowsClipboard.cpp,555: added fDEBUG: getDEBUG: CXWindowsClipboard.cpp,555: added f DEBUG: CXW8_STDEBUG: CXWindowsClipboard.cpp,555: added fDEBUG: CXWindowsClipboard.cpp,555: added fD textDEBUG: CXWindowsClipboard.cpp,555: added fDEBU DEBUG: CXWindowsClipboard.cpp,555: added fDEBUG: CXWindowsClipinDEBUG: CXWindowsClipboard.cpp,555:oardDEBUG: CXWindowsClipboard.cpp,555: added fDEBUG: CXWindowsClipboard.cpp,555: added fDEBUG: CXWindCXWDEBUG: CXWindowsClipboard.cpp,555: added fDEBUG:SerDEBUG: CXWindowsClipboard.cpp,555: ed DEBUG: CXWindowsClipboard.cpp,555: added fDEBUG: CXWindowsClipboard.cpp,555owsClDEBUG: CXWindowsClipboard.cpp,555: 1DEBUG: CXWindowsClipboard.cpp, s From the Mac: connecting to '192.168.3.5': 192.168.3.5:24800 connected to server entering screen leaving screen entering screen leaving screen stopped client

    Read the article

  • Low CPU performance with low usage and clock - Windows 8.1

    - by Daniele
    I recently deleted everything from my PC and reinstalled Windows 8.1 from scratch. When I first booted into Windows everything was extremely slow though the CPU usage was very low (about 1%). After installing some drivers the problem seemed to be solved, I was able to use my PC normally. Today I installed a game and I noticed a strange behavior: the game was playable but the performance worsened more and more in the time. This is the situation BEFORE opening the game (normal): This is AFTER some minutes inside the game (low CPU usage and clock): Some information about my system: PC: Sony Vaio S13 (SVS13A1C5E) OS: Windows 8.1 CPU: Intel Core i7-3520M 2.90GHz GPU(1): Intel HD Graphics 4000 GPU(2): NVIDIA GeForce GT 640M LE I tried searching for new drivers and other solutions but noting worked and I don't know what is the cause. I did not checked the temperatures but the fans are not running fast and the PC does not look overheated. Update: Max CPU Temp: 66°C, Max GPU Temp: 61°C The strange thing is that the GPU load is 99% (GPU-Z) and the fan is almost silent. Update 2: I had troubles with Sony Vaio software, I can't get the FN keys and the STAMINA/SPEED switch to work (it is a physical switch to enable/disable the Nvidia card and change the Power Profile). I'm saying this because I remember that before reinstalling Windows there was an option in the Vaio Control Center (now it is not there anymore) that allowed me to choose from something like "priority to performance (ventilation)" or "priority to silence". The current behavior looks like a "priority to silence", but I can't get the stamina-speed switch to work and so I don't see similar oprions in the Vaio Control Center. I don't know if the problem is related to this.

    Read the article

  • Network cabling with multiple patch panels?

    - by dannymcc
    I am in the very early stages of planning a network cabling upgrade in our office, mainly to upgrade the old cables from Cat5 to either 5e or 6. I am also planning on upgrading all of our 10/100 switches to 10/100/1000 switches. I would like to have three small wall mounted cabinets spread around the building, each with a patch panel and switch. These would all lead back to our server room. The question is; should I have two patch panels in each wall cabinet, one with 24 or 48 ports that are connected to a matching patch panel in the server room. The second patch panel would then link to each device in that cabinets area. Then I wouldn't put a switch in the small cabinets. All switching would be done in the server room. Or, should I have one main cable from the server room to each of the cabinets - plugged straight into the switch and the patch panel is for devices in the cabinets area? I hope that makes sense!

    Read the article

  • Put one monitor of a dual monitor windows system into standby

    - by Psycogeek
    Standby not Disabled! When running 2 monitors on windows 7 or Windows XP, I would like to be able to put one of the monitors at a time into standby. The method can be manual. When running 2 monitors , the second monitor is not always needed, shutting off the monitors own power switch will turn off the monitor, that does work Ok. Problems with that are , the delay with the monitor logo at turn on, and the power switch is not very accessable, and the switch might not live forever turning it on and off so many times. Using disable methods like devcon, WIN-P and Display, causes all the windows to properly move to the other monitor. While that is what a person would want to happen so they can get hold of the windows, that is not what I want to happen, and some things on the other monitor have to be re-arranged after a re-enable. By putting it into standby mode, nothing changes other than the monitor going into standby. Disconnecting the DVI cable still can cause the system to (properly) shift all the windows over to the one monitor, just like any of the disable methods do. That makes a mess of the windows, and is so unacceptable, that I would prefer to leave the monitor on, wasting power and the hardware, when it could easily go into standby for some time. For both monitors I am using a "MonitorOff" program that puts both monitors into standby, but I can not find a utility that will put only ONE monitor into standby for the windows system. If someone comes along and suggests "ultramon" you must know for a fact that it will put One of either of the monitors into actual standby. And it does not really suit me to use ultramon, I tested it (it was nice) and I did not feel that it was a program I wanted. The 2 monitors are running off of an ATI 4890 card, they are both hooked up DVI-I, the OS is both Windows 7 (primary) and Windows XP. In addition it would also be interesting to have seperate standby activity timers, and follow mouse kind of standby changes, but any manuel method , shortcut, batch , tray, or gadget kind of operation would be a good start.

    Read the article

  • Intermittent "Lost connection to MySQL server at 'reading initial communication packet'"

    - by db2
    Our web environment consists of two servers. Web front-end. Dell PowerEdge R610, RHEL 5.5, Apache 2.2.17, php 5.2.14. Database server. Dell PowerEdge R710, Windows 2008 R2 Standard x64, MySQL 5.5.11-log x64. Normally these two work perfectly fine together. However, when I try to get them talking via a dedicated LAN on their secondary NICs (each machine has four of them), things get flaky. I have NIC #2 on both machines configured on the 172.16.1.0/24 subnet, with no gateway or DNS servers (obviously, since it's just those two systems), and I put the private IP address of each machine into the hosts file of the other. The routing tables on both machines look okay after I do this. I've tried this with both a crossover cable draped directly between the two NICs, and also via a dedicated vlan on the switch in the rack. In either case, I get intermittent connection problems. It's a fairly small percentage of connections that fail, but it's enough to cause a significant problem, and I have to switch back to the main network connection, which will contend with all the other traffic and hosts on the switch. The full error message that appears in the application log: SQLSTATE[HY000] [2013] Lost connection to MySQL server at 'reading initial communication packet', system error: 110 Am I doing something really dumb that's causing this to not work properly? Anything I can check in MySQL that would explain why it's failing to connect occasionally?

    Read the article

  • suggestions for firewall/router project using *BSD or Linux

    - by Adeodatus
    Hi All, I have a project in mind and I'd love to hear some ideas on some open source solutions with COTS hardware. I have a few 24 and/or 48 port managed layer2 switches with customers potentially on each port (though its usually about 20-30). Right now the switch has a bridged network and backhaul the traffic to our core to a centralized DHCP server. I need to move them to a NAT solution and, while doing this, I'd like to protect the customers on each port from the customer traffic on the other ports. I also need to be able to port forward from the public side of the firewall/nat box to specific hardware on the inside of the nat machine (easy enough, I know). My first thoughts are to build an appliance-like box (the fewer moving parts the better) that can do filtering and NAT with rfc1918 an address range being handed out via a DHCP server on the appliance. A caching DNS server on the appliance would be a plus since we backhaul everything to the core. I'd like to run FreeBSD but I'm open. Now, to try to limit the broadcast traffic thats visible I was thinking of doing each port on the switch as a different vlan and have the switch do trunking to the private NIC on the FreeBSD/appliance. I'd probably need to do some magic on the freebsd NIC to get this working but it should. We have the parts to build these systems. So, does this make sense? Are there any other solutions out there that we don't have to spend money on but can use our parts to create something? Are there any good distros that could do this already (monowall)?? I may or may not admin this solution so a secure web configuration and management tool would be a plus in the other admins' minds. Thoughts?

    Read the article

  • How to wake from screensaver directly to the login screen in Ubuntu

    - by torbengb
    (a.k.a. How to switch users without entering password, part II) (see part I) I've got Ubuntu 9.10 with a user account for my wife, and one for myself. "Wake-from-screensaver" should result in "choose user" without having to enter any password. I know how to do that in Windows, but I'm not good with Linux (yet). Part of this was answered in my earlier question which helped me get past the login screen without passwords (after booting, and after choosing "switch user"), but once the screensaver kicks in and I wake it up again, the system does not present the "choose user" screen. Instead, it either turns off the screensaver and presents the desktop of the most recent user, or (if the screensaver is set to lock the screen) prompt for the user's password (which can be handily surpassed by clicking the "switch user" button and choosing the same user again). So, the login ("choose user") screen has been dealt with. How do I make the (any) screensaver return to the login screen at wake, rather than to the current user's desktop? Windows can do this, I'm sure Linux can too - but how?

    Read the article

  • VMware ARP/Mac Networking

    - by Ross Wilson
    Hi Guys, I am very interested in how VMware networking works. I have scoured the VMware website and read their data sheets, this has given me some basic knowledge. I now have some questions. Lets assume that we have a physical server running the VMware hypervisor. The physical server is running a Virtual Machine. The physical box has one physical NIC. The NIC is connected to a switch, as so is a desktop client. Now, this is where my first question lies. The VM has an IP address: 192.168.1.1. How do desktop clients on the network communicate with this VM? So, the client pings 192.168.1.1. The ping packet is sent to the switch. The switch checks its MAC address table and sees that 192.168.1.1 is associated with the MAC address of the physical NIC. Correct? I then assume that the ping packet is sent to the server's physical NIC, where the hypervisor routes the packet to the VM thats using 192.168.1.1? Please could you give me a run down as to how VM networking works? Many thanks, Ross

    Read the article

  • samba sync password with unix password on debian wheezy

    - by Oz123
    I installed samba on my server and I am trying to write a script to spare me the two steps to add user, e.g.: adduser username smbpasswd -a username My smb.conf states: # This boolean parameter controls whether Samba attempts to sync the Unix # password with the SMB password when the encrypted SMB password in the # passdb is changed. unix password sync = yes Further reading brought me to pdbedit man page which states: -a This option is used to add a user into the database. This com- mand needs a user name specified with the -u switch. When adding a new user, pdbedit will also ask for the password to be used. Example: pdbedit -a -u sorce new password: retype new password Note pdbedit does not call the unix password syncronisation script if unix password sync has been set. It only updates the data in the Samba user database. If you wish to add a user and synchronise the password that im- mediately, use smbpasswd’s -a option. So... now I decided to try adding a user with smbpasswd: 1st try, unix user still does not exist: root@raspberrypi:/home/pi# smbpasswd -a newuser New SMB password: Retype new SMB password: Failed to add entry for user newuser. 2nd try, unix user exists: root@raspberrypi:/home/pi# useradd mag root@raspberrypi:/home/pi# smbpasswd -a mag New SMB password: Retype new SMB password: Added user mag. # switch to user pi, and try to switch to mag root@raspberrypi:/home/pi# su pi pi@raspberrypi ~ $ su mag Password: su: Authentication failure So, now I am asking myself: how do I make samba passwords sync with unix passwords? where are samba passwords stored? Can someone help enlighten me?

    Read the article

  • What is the minimal steps to setup a client-server network using Windows Server 2008 R2 standard?

    - by Motivated Student
    Background I have One computer server with Win Server 2008 R2 standard installed but it has not been configured. This server has 2 LAN adapters. One adapter is connected to ISP and the other one connected to HUB/Switch. Other computers working as clients are connected to the same HUB/Switch to which the server is connected. IP Printers, IP scanners, IP camera are also connected to the same HUB/Switch. Note: I am a newbie. I only know how to plug RJ-45 sockets and assembly computer peripherals. I have no prior experience in Windows Server at all. Please teach me from the newbie's point of view. Objective I want to establish the following: Each client can access the internet, printers, scanners after it has been successfully authenticated by the server. Unauthenticated clients cannot access the internet, printers, etc. The server hosts a local site. Clients can browse internally using a private domain www.company.com. If the same domain name has been used by other on the internet, my private domain must override the public domain.

    Read the article

  • Make a snapshot of a live mySQL database with myISAM & innoDB tables without locking

    - by Artem
    We have a live database in production where we are running out of space on the server. So I would like to transfer to a new server without any downtime (or as little downtime as possible). In general, I would also like to have a hot failover copy of the database available. I would like to use replication to get all of the data copied to the new machine, and then at some point flip a switch and have that new machine become the master (normal failover scenario). My problem is that I am not sure how to initialize replication without locking the db to make the initial snapshot I will use? Is there any way to do this? I know I could do it using single-transaction if I was using innoDB, but very unfortunately we have some myISAM tables in there (in fact the largest 150GB table is myISAM and I want to switch it to InnoDB but I can't do it until I have more space & a hot copy to switch to). Any ideas? Is there some way to make such a snapshot? Or is there alternatively a way to get replication to "catch up" without an snapshot for initialization?

    Read the article

  • Networking - intermittent, slow speeds

    - by jack
    Hi all I'm a novice when it comes to networking. I live in a large two storey building that used to be a school and we have an internet connection with BT (british telecoms provider), the connection speed is 12Mb.. Basically our connection is slow and very intermittent and I was wondering if anybody here could provide some help or ideas. There are about 11 people in the building who could be online at any time. We have a router on the ground floor which is bog standard supplied by BT. To provide Broadband access to the 1st and 2nd floors, we used an old switch that the school left, we have a cable running from the router on the first floor to the switch which connects to a wireless router which is configured as a bridge on the 2nd floor supplying broadband access to the 1st and 2nd floors. Additionally we have 3 computers that are connected via the switch through the ethernet sockets left by the school on the ground floor. The router we use on the 2nd floor came in a pack of 2 and cost about £15 (bought by another person). Sometimes the connection is perfectly fine, i.e. early hours of the morning or when everybody is out, we have rang BT who say that the connection cannot cope with the numbers of people online, plus I'm not sure whether each person is streaming etc. Can anybody offer any advice?

    Read the article

  • Slow File Copy observed copying 40GB files across network to iSCSI device

    - by Rick
    Here's a curious ones for the gurus: Setup: Source Machine: Windows Server 2003 R2 machine with local hard drive. VHD file of 40GB. 1 x 1Gbps network card, Cat6 cable, switch. Target Machine: Windows Server 2008 R2 machine with iSCSI connection to iSCSI target on separate machine (1TB, RAID5). 1 x 1Gbps network card, Cat6 cable, connected to same switch as for Source Machine. Second 1Gbps network card, Cat6 cable, connected via isolated switch to the iSCSI target. Switches are Netgear JGS524 model (web managed). If I copy from the Win2003R2 machine to Win2008R2 machine local drive I get 40GB in 45 minutes, 36 seconds. If I copy from the Win2008R2 machine to the iSCSI target (local drive to iSCSI target) I get 40GB in 37 minutes 56 seconds. If I copy from the Win2003R2 machine to the iSCSI target via the Win2008R2 machine I get 40GB in 3 hours, 50 minutes, 24 seconds. All copies were done via the following command issued on the Win2008R2 box: XCOPY <source> <target> /J XCOPY /J - Copies using unbuffered I/O. Recommended for very large files. So, what's the bit I'm missing here? Why does a back-to-back copy take in total 1 hour, 23 minutes, 32 seconds when a "straight through" copy take almost 3 times as long? Switches show no errors, network hovers around the 3% utilisation mark for the duration of the copy (whereas the "back-to-back" copies are around the 25% utilisation mark). What have I missed?

    Read the article

  • How do I specify the emergency location in CDP?

    - by chrish
    In the LLDP-MED and Cisco Discovery Protocol whitepaper, it compares LLDP-MED and CDP. The part I am interested in is emergency location configuration. In LLDP-MED, I can specify the Emergency Line Indentification Number (ELIN) and that number will be used by some IP Phones (e.g. Aastra) when placing emergency calls. The whitepaper states: Location Identification Discovery This capability is important because it normally provides location information from the switch to the phone. (If the phone is configured with location information or can determine its location, then it may send this information to the switch. However, the real value is getting this information from the switch to the phone for phones that cannot determine their own location.) Location identification discovery allows the phone to be aware of its location-information that can be used for location-based applications on the phone. More importantly, this capability can be used to provide location information when making emergency calls. Both Cisco Discovery Protocol and LLDP-MED support the transportation of location information. However, LLDP-MED has more supported data formats than Cisco Discovery Protocol. I have found the documentation on how to set the location and associate the location to the interfaces for LLDP-MED. How is this done for CDP? Is ELIN supported for CDP?

    Read the article

  • Win 7 dual monitor: Don't move application windows when turn off second monitor

    - by codewaggle
    The title is correct, it should say "Don't" not "Doesn't". I Don't want the application windows to be moved to the main monitor when I turn off the monitors. On my Win XP dual monitor system, I can turn off the monitors and when I turn them back on, the application windows are in the same locations on the same monitors as when I turned the monitors off. On the Win 7 system, every time I turn off the monitors (or just the second monitor), all of the application windows are moved to the "main" monitor. After experimenting with the settings, I've found one process that enables me to turn off the monitors and still keep my application windows laid out in my chosen locations on the two monitors: 1) Switch the display setting to a single monitor. 2) Turn off the monitors. 3) Turn on the monitors. 4) Switch the display setting back to "Extend these Displays". After step 4, the application windows that I had laid out on the second monitor are moved back to their original locations on the second monitor. Is there a windows or nVidia setting that would leave the application windows on the second monitor so that I don't need to switch the display settings every time I turn off the monitors? Specs: Windows 7 64-bit dual monitors (1 DP, 1 DVI) Desktop (most questions seem to be about laptops) nVidia Quadro 2000 nVidia Control Panel nVidia nView Control Panel

    Read the article

  • Home network with two isolated separate subnets, running on cablemodem/router and WRT-router.

    - by Johan Allgoth
    I have a new connection with a nice new router/cable-modem. I'd like to setup it up optimally and needs some pointers. I am a complete n00b when it comes to routing. I want to end up with two separate subnets, 10.1.2.0/24 and 192.168.1.0/24 each available on their own wireless channel/SSID. Both firewalled. I want my wired computers on the gigabit switch, optimally with public ips. I want to be able to reach 192.168.1.0/24 from 10.1.2.0/24, but not vice versa. Everyone should have internet access. Hardware and capabilities: Netgear CG3100. Handles cable connection. Gigabit switch. 802.11n. Can do DHCP, firewall, NAT etc. Can choose subnet. Can turn of NAT and if so hand out up to 4 public ips. Somewhat challenged when it comes to configuration. WRT-router. Runs DD/Open-WRT very stable. 100 Mbit switch. 802.11.g Can do DHCP, firewall, NAT etc. Can choose subnet. Highly configurable. I hope to be able to keep 10.1.2.0/24 on the CG3100, for speed reasons and 192.168.0.0/24 on the WRT-router for quota and user control reasons. On my 10.1.2.0/24 network I plan on running servers for various services. Should I turn of NAT on the WRT-router? Or on the cable modem? Activate what in that case? Is double NAT always f-ed up?

    Read the article

  • Video desktop recording and multiple WM displays, capturing nonactive display

    - by okobaka
    Two WM running on one local machine. WM - Fluxbox. Using ffmpeg to record desktop. ffmpeg -an -f x11grab -s 1920x1080 -r 25 -i :1.0 -sameq /tmp/video.mkv On one display everything works great, but not when i have another WM display startx -- :1. What i am doing right now is to switch ctrl+alt+f8 to display:1.0, and start recording with ffmpeg. Everything is fine until i switch back ctrl+alt+f7 to display:0.0, WM and captured video image freezes, but when i switch back ctrl+alt+f8 to display:1.0, it unfreeze and continue recording. So, how to make display:1.0 not to freeze, while on display:0.0? Tested some more. open [display 0.0] open [display 0.1] from [display 0.0] = open => [display 0.2] same problem For different users and same users results are the same. ffmpeg keeps recording that paused image. Looks like WM root window need to be active, to be recorded.

    Read the article

  • Computer turns itself on after any off mode

    - by Patrick
    Whenever I shut down my computer, or put it in sleep/hybernate, it turns on after two seconds. It doesn't post, it just powers on and then idles. To actually turn it off, I switch off the psu. The problem is now, whenever I switch the psu on and try to boot, it doesn't always turn on. It takes a good amount of flicking the psu switch on and off before the motherboard lights up. So far I've determined the things its not: its not caused by the mouse or network waking up the computer. I've been able to go into hybernate for the past year. And all "wake on X" settings in the bios are diabled. its not a scheduled task waking up the computer at a given hour, it occurs every single time its not due to an upgrade or new installation, since I haven't done either in a very long time I'm sure its a hardware issue. So I'd like to know, is my psu dead, or the motherboard? The psu is an Antec Earthwatts 600w, the motherboard is an Asus P5Q-E, both one year old.

    Read the article

  • Server 2012, Jumbo Frames - should I expect problems?

    - by TomTom
    Ok, this sound might stupid - but is there any negative on just enabling jumbo frames in practice? From what I understand: Any switch or ethernet adapter that sees a jumbo frame it can not handle will just drop it. TCP is not a problem as max frame size is negotiated in the setinuo phase. UCP is a theoretical problem as a server may just send a LARGE UDP packet that gets dropped on the way. Practically though, as UDP is packet based, I do not really think any software WOULD send a UDP packet larger than 1500 bytes net without app level configuration changes - at least this is how I do my programming, as it is quite hard to get a decent MTU size for that without testing yourself, so you fall back in programming to max 1500 packets. The network in question is a standard small business network - we upgraded now from a non managed 24 port switch to a 52 port switch with 4 10g ports (netgear - quite cheap) and will mov a file server to 10g for also ISCSI serving. All my equipment on the Ethernet level can handle minimum 9000 bytes and due to local firewalls I really want to get packets larger (less firewall processing), but the network is also NAT'ed to the internet. On top, different machines move around (download) large files (multi gigabyte area) quite often for processing. The question is - can I expect problems when I just enable jumbo frames? Again, this is not totally ignorance - I just don't see programs sending more than 1500 byte UDP packets (if that is a practical problem please tell me) and for TCP the MTU is negotiated anyway. if there is a problem I can move to a dedicated VLAN, but this has it's own shares of problems as basically most workstations must then be on both VLAN's.

    Read the article

  • Restricting Access to Application(s) on Point of Sale system

    - by BSchlinker
    I have a customer with two point of sale systems, a few workstations and a Windows 2003 SBS Server. The point of sale systems are typically running QuickBooks Point of Sale and are logged in with a user who has restricted permissions / access (via Group Policy). Occasionally, one of the managers needs to be able to run a few additional applications -- including some accounting software. I have created an additional user for this manager, allowing them to login and access the accounting software. The problem is, it can be problematic to switch users on the system, as QuickBooks takes a few minutes to close (on POSUser) and then reopen (on ManagerUser). If customers are waiting, this slows things down drastically. Since the accounting software is stored on a network drive, it would be easiest if the manager could simply double click something, authenticate against the network drive / domain controller and then the program would launch. When they close the program, the session to the network drive would be lost and the program would no longer be accessible. Is there any easy way to do this? Both users are on a domain and the system is Windows 7. I just don't want to require the user to switch back and forth. In a worst case scenario, they forget to switch back and leave the accounting software wide open.

    Read the article

  • Bridging my laptop's wireless and wired adaptors

    - by stacey.richards
    I would like to be able to connect a desktop computer that does not have a wireless adapter to my wireless network. I could just run a network cable from my ADSL/wireless router to the desktop computer but sometimes this is not practical. What I would really like to do is bridge my laptop's wireless and wired adapters in such a way that I can run a network cable from my laptop to a switch and another network cable from the switch to a desktop computer so that the desktop computer can access the Internet through my ADSL/wireless router via my latop: +--------------------+ |ADSL/wireless router| +--------------------+ | +-------------------------+ |laptop's wireless adaptor| | | |laptop's wired adaptor | +-------------------------+ | +------+ |switch| +------+ | +-----------------------+ |desktop's wired adapter| +-----------------------+ A bit of Googling suggests that I can do this by bridging my laptop's wireless and wired adapters. In Windows XP's Network Connections I select both the Local Area Connection and the Wireless Network Connection, right click and select Bridge Connections. From what I gather, this (layer 2?) bridge will examine the MAC address of traffic coming from the wireless network and pass it through to the wired network if it suspects that a network adapter with that MAC address may be on the wired side, and vice-versa. If this is the case, I would assume that when the desktop computer attempts to get an IP address from a DHCP server (which is running on the ADSL/wireless router), it would send a DHCP broadcast packet which would pass through the laptop's bridge to the router and the reply would return through the laptop's bridge back to the desktop. This doesn't happen. With some more Googling I find some instruction how this can be done with Linux. I reboot to Ubuntu 9.10 and type the following: sudo apt-get install bridge-utils sudo brctl addbr br0 sudo brctl addif br0 wlan0 sudo brctl addif br0 eth0 sudo ipconfig wlan0 0.0.0.0 sudo ipconfig eth0 0.0.0.0 Once again, the desktop cannot reach the ADSL/wireless router. I suspect that I'm missing some simple important step. Can anyone shed some light on this for me?

    Read the article

  • FWBuilder DNS Object Run Time - when exactly does it resolve the DNS name?

    - by Jakobud
    In Firewall Builder, when you use the DNS Object and set it to run time, when exactly does the firewall (iptables in our case) actually resolve the DNS name? Is it whenever a call is made to that DNS name in the firewall? So the firewall would resolve the name on the fly whenever someone/something tries to access that DNS name? Or is it when you execute the fw script to load the rules into iptables? So in this case, it would resolve the DNS name that one time and then hard-code the resulting ip address into the iptable rules? From what I read, I think its #1, but it's just not 100% clear to me. We have two servers for a certain function on our network. One is the primary server and one is backup. alpha0.domain.com alpha1.domain.com In DNS we have this: alpha.domain.com -> alpha0.domain.com If the primary server goes down and we need to switch to the backup, I just change our local DNS record to point to alpha1.domain.com instead. So back to the firewall, if I just put in a Domain Object as alpha.domain.com, do I have to reload the firewall rules every time we switch to the backup alpha server and change the DNS record? Or will the firewall automatically resolve to the correct address even after the switch?

    Read the article

  • 10GE network: Is it still deadly expensive? Any options?

    - by BarsMonster
    Hi! I am building home cluster where I going to have about 16 nodes which can live with 1G ports, but I really want to have 10GE on file server & central node. It's all local, so no need for cabels longer than 3-5m. And ofcourse I want to spend as little money as possible (not going to spend more than whole cluster costs) :-) What are my options? 1) Legacy solution is to take some 24-48 port 1GE switch, and connect to file/central nodes via 4-8 aggregated links. This will work I guess, cost is very acceptable, but I am not sure if it's ok to use that much aggregated links. And ofcourse it would be hard to double bandwidth when needed... :-D 2) Switch with several 10GE uplink 'ports'. As far as I see, they all require modules which costs about 1000$, so I will need 4 10G modules, and 2 10GE cards... Smells like way more than 5000$+... 3) Connect file & central node via 2 10G cards directly, and put 4 quadport 1GE NICs on fileserver. I am saving on 2 10G modules and a switch, fileserver will have to do packet routing, but it's still gonna have alot of CPU's left :-) 4) Any other options? Infiniband? 5) Are MyriNet adaptors works fine? I guess there are no cheaper options? 6) Hmm... Scrap fileserver, put it all on central node and provide dedicated 1GE port for each of the nodes... This is sad...

    Read the article

< Previous Page | 125 126 127 128 129 130 131 132 133 134 135 136  | Next Page >