Search Results

Search found 81493 results on 3260 pages for 'file size'.

Page 133/3260 | < Previous Page | 129 130 131 132 133 134 135 136 137 138 139 140  | Next Page >

  • Reading bmp file for steganography

    - by Shantanu Gupta
    I am trying to read a bmp file in C++(Turbo). But i m not able to print binary stream. I want to encode txt file into it and decrypt it. How can i do this. I read that bmp file header is of 54 byte. But how and where should i append txt file in bmp file. ? I know only Turbo C++, so it would be helpfull for me if u provide solution or suggestion related to topic for the same. int main() { ifstream fr; //reads ofstream fw; // wrrites to file char c; int random; clrscr(); char file[2][100]={"s.bmp","s.txt"}; fr.open(file[0],ios::binary);//file name, mode of open, here input mode i.e. read only if(!fr) cout<<"File can not be opened."; fw.open(file[1],ios::app);//file will be appended if(!fw) cout<<"File can not be opened"; while(!fr) cout<<fr.get(); // error should be here. but not able to find out what error is it fr.close(); fw.close(); getch(); } This code is running fine when i pass txt file in binary mode

    Read the article

  • Undefined method 'size' for #<File:text.txt> (NoMethodError)

    - by user1354456
    This is the code I am running, it does fine until I get to line 15. The command I run is: ruby ex16.rb text.txt. This is a practice sample I'm writing which is meant to be a simple little text editor: filename = ARGV.first script = $0 puts "We're going to erase #{filename}." puts "if you don't want that, hit CTRL-C (^C)." puts "If you do want that, hit RETURN." print "? " STDIN.gets puts "Opening the file..." target = File.open(filename, 'w') puts "Truncating the file. Goodbye!" target.truncate(target.size) puts "Now I'm going to ask you for three lines." print "line 1: "; line1 = STDIN.gets.chomp() print "line 2: "; line2 = STDIN.gets.chomp() print "line 3: "; line3 = STDIN.gets.chomp()undefined method 'size' puts "I'm going to write these to the file." target.write(line1) target.write("\n") target.write(line2) target.write("\n") target.write(line3) target.write("\n") puts "And finally, we close it." target.close()

    Read the article

  • Expand and Shrink UIScrollView with animation

    - by Dilip Rajkumar
    I am having a UITableView inside a scrollview. So I am trying to do a accordion like component using UITableView. So I need to expand the UITableView to add more cell. In that case I have to increase the height of UIScrollView with a animation so that it matches the table animation. - (NSIndexPath *)tableView:(UITableView *)tableView willSelectRowAtIndexPath:(NSIndexPath *)indexPath { NSInteger row = [indexPath row]; BOOL preventReopen = NO; if (row == expandedRowIndex + 1 && expandedRowIndex != -1) return nil; [tableView beginUpdates]; if (expandedRowIndex != -1) { familyTableView.frame = CGRectMake(familyTableView.frame.origin.x, familyTableView.frame.origin.y, familyTableView.frame.size.width, 3*50+22); toolsTableView.frame = CGRectMake(toolsTableView.frame.origin.x, familyTableView.frame.origin.y + familyTableView.frame.size.height + 20, toolsTableView.frame.size.width, 4*50+22); myAccountTableView.frame = CGRectMake(myAccountTableView.frame.origin.x, toolsTableView.frame.origin.y + toolsTableView.frame.size.height + 20, myAccountTableView.frame.size.width, 2*50+22); settingsScrollView.contentSize = CGSizeMake(320, familyTableView.frame.size.height + toolsTableView.frame.size.height+ myAccountTableView.frame.size.height + 380); settingsScrollView.contentInset = UIEdgeInsetsMake(0, 0, familyTableView.frame.size.height + toolsTableView.frame.size.height+ myAccountTableView.frame.size.height + 380, 0); NSInteger rowToRemove = expandedRowIndex + 1; preventReopen = row == expandedRowIndex; if (row > expandedRowIndex) row--; expandedRowIndex = -1; [tableView deleteRowsAtIndexPaths:[NSArray arrayWithObject:[NSIndexPath indexPathForRow:rowToRemove inSection:0]] withRowAnimation:UITableViewRowAnimationTop]; }else { familyTableView.frame = CGRectMake(familyTableView.frame.origin.x, familyTableView.frame.origin.y, familyTableView.frame.size.width, (3*50+22) + 100); toolsTableView.frame = CGRectMake(toolsTableView.frame.origin.x, familyTableView.frame.origin.y + familyTableView.frame.size.height + 20, toolsTableView.frame.size.width, 4*50+22); myAccountTableView.frame = CGRectMake(myAccountTableView.frame.origin.x, toolsTableView.frame.origin.y + toolsTableView.frame.size.height + 20, myAccountTableView.frame.size.width, 2*50+22); settingsScrollView.contentSize = CGSizeMake(320, familyTableView.frame.size.height + toolsTableView.frame.size.height+ myAccountTableView.frame.size.height + 380); settingsScrollView.contentInset = UIEdgeInsetsMake(0, 0, familyTableView.frame.size.height + toolsTableView.frame.size.height+ myAccountTableView.frame.size.height + 380, 0); } NSInteger rowToAdd = -1; if (!preventReopen) { rowToAdd = row + 1; expandedRowIndex = row; [tableView insertRowsAtIndexPaths:[NSArray arrayWithObject:[NSIndexPath indexPathForRow:rowToAdd inSection:0]] withRowAnimation:UITableViewRowAnimationTop]; } [tableView endUpdates]; return nil; } I am not good at animation. Any help is greatly appreciated. What I need is when we do [tableView beginUpdates] we have to start animating the resize effect to UIScrollView and it should end when [tableView endUpdates] executes. So the Accordion executes flawlessly. Thanks in advance for any help..

    Read the article

  • How do i resize image file to optional sizes

    - by shuxer
    Hi I have image upload form, user attaches aimage file, and selects image size to resize the uploaded image file(200kb, 500kb, 1mb, 5mb, Original). Then my script needs to resize image file size based on user's optional size, but im not sure how to implement this feature, For example, user uploads image with one 1mb size, and if user selects 200KB to resize, then my script should save it with 200kb size. Does anyone know or have an experience on similar task ? Thanks for you reply in advance.

    Read the article

  • An easy way to create Side by Side registrationless COM Manifests with Visual Studio

    - by Rick Strahl
    Here's something I didn't find out until today: You can use Visual Studio to easily create registrationless COM manifest files for you with just a couple of small steps. Registrationless COM lets you use COM component without them being registered in the registry. This means it's possible to deploy COM components along with another application using plain xcopy semantics. To be sure it's rarely quite that easy - you need to watch out for dependencies - but if you know you have COM components that are light weight and have no or known dependencies it's easy to get everything into a single folder and off you go. Registrationless COM works via manifest files which carry the same name as the executable plus a .manifest extension (ie. yourapp.exe.manifest) I'm going to use a Visual FoxPro COM object as an example and create a simple Windows Forms app that calls the component - without that component being registered. Let's take a walk down memory lane… Create a COM Component I start by creating a FoxPro COM component because that's what I know and am working with here in my legacy environment. You can use VB classic or C++ ATL object if that's more to your liking. Here's a real simple Fox one: DEFINE CLASS SimpleServer as Session OLEPUBLIC FUNCTION HelloWorld(lcName) RETURN "Hello " + lcName ENDDEFINE Compile it into a DLL COM component with: BUILD MTDLL simpleserver FROM simpleserver RECOMPILE And to make sure it works test it quickly from Visual FoxPro: server = CREATEOBJECT("simpleServer.simpleserver") MESSAGEBOX( server.HelloWorld("Rick") ) Using Visual Studio to create a Manifest File for a COM Component Next open Visual Studio and create a new executable project - a Console App or WinForms or WPF application will all do. Go to the References Node Select Add Reference Use the Browse tab and find your compiled DLL to import  Next you'll see your assembly in the project. Right click on the reference and select Properties Click on the Isolated DropDown and select True Compile and that's all there's to it. Visual Studio will create a App.exe.manifest file right alongside your application's EXE. The manifest file created looks like this: xml version="1.0" encoding="utf-8"? assembly xsi:schemaLocation="urn:schemas-microsoft-com:asm.v1 assembly.adaptive.xsd" manifestVersion="1.0" xmlns:asmv1="urn:schemas-microsoft-com:asm.v1" xmlns:asmv2="urn:schemas-microsoft-com:asm.v2" xmlns:asmv3="urn:schemas-microsoft-com:asm.v3" xmlns:dsig="http://www.w3.org/2000/09/xmldsig#" xmlns:co.v1="urn:schemas-microsoft-com:clickonce.v1" xmlns:co.v2="urn:schemas-microsoft-com:clickonce.v2" xmlns="urn:schemas-microsoft-com:asm.v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" asmv2:size="27293" hash xmlns="urn:schemas-microsoft-com:asm.v2" dsig:Transforms dsig:Transform Algorithm="urn:schemas-microsoft-com:HashTransforms.Identity" / dsig:Transforms dsig:DigestMethod Algorithm="http://www.w3.org/2000/09/xmldsig#sha1" / dsig:DigestValuepuq+ua20bbidGOWhPOxfquztBCU=dsig:DigestValue hash typelib tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" version="1.0" helpdir="" resourceid="0" flags="HASDISKIMAGE" / comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file assembly Now let's finish our super complex console app to test with: using System; using System.Collections.Generic; using System.Text; namespace ConsoleApplication1 {     class Program     {         static voidMain(string[] args)         { Type type = Type.GetTypeFromProgID("simpleserver.simpleserver",true); dynamic server = Activator.CreateInstance(type); Console.WriteLine(server.HelloWorld("rick")); Console.ReadLine(); } } } Now run the Console Application… As expected that should work. And why not? The COM component is still registered, right? :-) Nothing tricky about that. Let's unregister the COM component and then re-run and see what happens. Go to the Command Prompt Change to the folder where the DLL is installed Unregister with: RegSvr32 -u simpleserver.dll      To be sure that the COM component no longer works, check it out with the same test you used earlier (ie. o = CREATEOBJECT("SimpleServer.SimpleServer") in your development environment or VBScript etc.). Make sure you run the EXE and you don't re-compile the application or else Visual Studio will complain that it can't find the COM component in the registry while compiling. In fact now that we have our .manifest file you can remove the COM object from the project. When you run run the EXE from Windows Explorer or a command prompt to avoid the recompile. Watch out for embedded Manifest Files Now recompile your .NET project and run it… and it will most likely fail! The problem is that .NET applications by default embeds a manifest file into the compiled EXE application which results in the externally created manifest file being completely ignored. Only one manifest can be applied at a time and the compiled manifest takes precedency. Uh, thanks Visual Studio - not very helpful… Note that if you use another development tool like Visual FoxPro to create your EXE this won't be an issue as long as the tool doesn't automatically add a manifest file. Creating a Visual FoxPro EXE for example will work immediately with the generated manifest file as is. If you are using .NET and Visual Studio you have a couple of options of getting around this: Remove the embedded manifest file Copy the contents of the generated manifest file into a project manifest file and compile that in To remove an embedded manifest in a Visual Studio project: Open the Project Properties (Alt-Enter on project node) Go down to Resources | Manifest and select | Create Application without a Manifest   You can now add use the external manifest file and it will actually be respected when the app runs. The other option is to let Visual Studio create the manifest file on disk and then explicitly add the manifest file into the project. Notice on the dialog above I did this for app.exe.manifest and the manifest actually shows up in the list. If I select this file it will be compiled into the EXE and be used in lieu of any external files and that works as well. Remove the simpleserver.dll reference so you can compile your code and run the application. Now it should work without COM registration of the component. Personally I prefer external manifests because they can be modified after the fact - compiled manifests are evil in my mind because they are immutable - once they are there they can't be overriden or changed. So I prefer an external manifest. However, if you are absolutely sure nothing needs to change and you don't want anybody messing with your manifest, you can also embed it. The option to either is there. Watch for Manifest Caching While working trying to get this to work I ran into some problems at first. Specifically when it wasn't working at first (due to the embedded schema) I played with various different manifest layouts in different files etc.. There are a number of different ways to actually represent manifest files including offloading to separate folder (more on that later). A few times I made deliberate errors in the schema file and I found that regardless of what I did once the app failed or worked no amount of changing of the manifest file would make it behave differently. It appears that Windows is caching the manifest data for a given EXE or DLL. It takes a restart or a recompile of either the EXE or the DLL to clear the caching. Recompile your servers in order to see manifest changes unless there's an outright failure of an invalid manifest file. If the app starts the manifest is being read and caches immediately. This can be very confusing especially if you don't know that it's happening. I found myself always recompiling the exe after each run and before making any changes to the manifest file. Don't forget about Runtimes of COM Objects In the example I used above I used a Visual FoxPro COM component. Visual FoxPro is a runtime based environment so if I'm going to distribute an application that uses a FoxPro COM object the runtimes need to be distributed as well. The same is true of classic Visual Basic applications. Assuming that you don't know whether the runtimes are installed on the target machines make sure to install all the additional files in the EXE's directory alongside the COM DLL. In the case of Visual FoxPro the target folder should contain: The EXE  App.exe The Manifest file (unless it's compiled in) App.exe.manifest The COM object DLL (simpleserver.dll) Visual FoxPro Runtimes: VFP9t.dll (or VFP9r.dll for non-multithreaded dlls), vfp9rENU.dll, msvcr71.dll All these files should be in the same folder. Debugging Manifest load Errors If you for some reason get your manifest loading wrong there are a couple of useful tools available - SxSTrace and SxSParse. These two tools can be a huge help in debugging manifest loading errors. Put the following into a batch file (SxS_Trace.bat for example): sxstrace Trace -logfile:sxs.bin sxstrace Parse -logfile:sxs.bin -outfile:sxs.txt Then start the batch file before running your EXE. Make sure there's no caching happening as described in the previous section. For example, if I go into the manifest file and explicitly break the CLSID and/or ProgID I get a detailed report on where the EXE is looking for the manifest and what it's reading. Eventually the trace gives me an error like this: INFO: Parsing Manifest File C:\wwapps\Conf\SideBySide\Code\app.EXE.     INFO: Manifest Definition Identity is App.exe,processorArchitecture="x86",type="win32",version="1.0.0.0".     ERROR: Line 13: The value {AAaf2c2811-0657-4264-a1f5-06d033a969ff} of attribute clsid in element comClass is invalid. ERROR: Activation Context generation failed. End Activation Context Generation. pinpointing nicely where the error lies. Pay special attention to the various attributes - they have to match exactly in the different sections of the manifest file(s). Multiple COM Objects The manifest file that Visual Studio creates is actually quite more complex than is required for basic registrationless COM object invokation. The manifest file can be simplified a lot actually by stripping off various namespaces and removing the type library references altogether. Here's an example of a simplified manifest file that actually includes references to 2 COM servers: xml version="1.0" encoding="utf-8"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name = "sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" threadingModel="apartment" / file assembly Simple enough right? Routing to separate Manifest Files and Folders In the examples above all files ended up in the application's root folder - all the DLLs, support files and runtimes. Sometimes that's not so desirable and you can actually create separate manifest files. The easiest way to do this is to create a manifest file that 'routes' to another manifest file in a separate folder. Basically you create a new 'assembly identity' via a named id. You can then create a folder and another manifest with the id plus .manifest that points at the actual file. In this example I create: App.exe.manifest A folder called App.deploy A manifest file in App.deploy All DLLs and runtimes in App.deploy Let's start with that master manifest file. This file only holds a reference to another manifest file: App.exe.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / dependency dependentAssembly assemblyIdentity name="App.deploy" version="1.0.0.0" type="win32" / dependentAssembly dependency assembly   Note this file only contains a dependency to App.deploy which is another manifest id. I can then create App.deploy.manifest in the current folder or in an App.deploy folder. In this case I'll create App.deploy and in it copy the DLLs and support runtimes. I then create App.deploy.manifest. App.deploy.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.deploy" type="win32" version="1.0.0.0" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name="sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" threadingModel="Apartment" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" / file assembly   In this manifest file I then host my COM DLLs and any support runtimes. This is quite useful if you have lots of DLLs you are referencing or if you need to have separate configuration and application files that are associated with the COM object. This way the operation of your main application and the COM objects it interacts with is somewhat separated. You can see the two folders here:   Routing Manifests to different Folders In theory registrationless COM should be pretty easy in painless - you've seen the configuration manifest files and it certainly doesn't look very complicated, right? But the devil's in the details. The ActivationContext API (SxS - side by side activation) is very intolerant of small errors in the XML or formatting of the keys, so be really careful when setting up components, especially if you are manually editing these files. If you do run into trouble SxsTrace/SxsParse are a huge help to track down the problems. And remember that if you do have problems that you'll need to recompile your EXEs or DLLs for the SxS APIs to refresh themselves properly. All of this gets even more fun if you want to do registrationless COM inside of IIS :-) But I'll leave that for another blog post…© Rick Strahl, West Wind Technologies, 2005-2011Posted in COM  .NET  FoxPro   Tweet (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article

  • ffmpeg: Could not find codec parameters for stream 0 (Video: h264) unspecified size

    - by dempap
    I try to convert a video from .raw to .mp4. For this reason I did download, build and install both x264 and ffmpeg. However, command: ffmpeg -f h264 -i output.raw -vcodec copy output.mp4 fails with error (shown in picture below). Is there any way to fix this? Commands I also run: 1 root@beagleboard:/# v4l2-ctl --list-formats ioctl: VIDIOC_ENUM_FMT Index : 0 Type : Video Capture Pixel Format: 'YUYV' Name : YUV 4:2:2 (YUYV) Index : 1 Type : Video Capture Pixel Format: 'MJPG' (compressed) Name : MJPEG 2 root@beagleboard:/dev# v4l2-ctl --set-fmt-video=pixelformat=0

    Read the article

  • Perforce: File tampered with after resolve - edit or revert

    - by fbrereto
    I'm doing an integration in Perforce and am being met with the following: p4 integrate -1 -d -i -t -r -b my_branchspec //Foo/file.txt#6 - integrate from //Bar/file.txt#6 p4 resolve -am /Foo/file.txt - merging //Bar/file.txt#6 /Foo/file.txt tampered with before resolve - edit or revert. It seems no matter what I do, I am unable to make this issue go away: the next forward integration will show a similar message. The file is a text file. I can confirm that the MD5 hash for both files before the integration takes place is the same. What other issues might be going on with this file that I can resolve to fix this nagging message?

    Read the article

  • Problem with XLSX file on Office 2003 with Compatibility Pack

    - by MadBoy
    I've this machine which has Office 2003 installed with Compatibility Pack. User received one file which she has to work with in XLSX format (file has to stay in that format so options to save it as XLS can be skipped). When she opens the file from Desktop or any other location it gives an error like "Cannot find the file in following location" and in the background it starts Converting XLSX file to XLS. In the end Excel is opened up with some random file name X000008.xls (Read Only) which is just 1 to 1 conversion of the XLSX document. However if I go directly to Excel and use File / Open and try to open the XLSX file no error or conversion is done. The file is writable and can be saved in XLSX format. The file name is simple like This_file something.XLSX, I've even tried to remove all spaces but it gave no better results. Anyone has any recommendations? So far I have done: 1. Uninstalled Compatibility Pack and installed it again. Tried opening it without any other updates and the error still pops out. In progress: I am now running all possible updates of office (like 5 of them) which i suppos won't fix anything (as they were applied when I've uninstalled compatibility pack). Next in run will be (not yet done) installing Windows XP SP3. What other things I can do?

    Read the article

  • max_binlog_size & log-bin size

    - by waza123
    I have a problem with full disk -rw-rw---- 1 mysql mysql 1073741982 2012-07-03 18:14 mysql-bin.000034 -rw-rw---- 1 mysql mysql 1073741890 2012-07-04 14:39 mysql-bin.000035 -rw-rw---- 1 mysql mysql 1073741988 2012-07-05 09:16 mysql-bin.000036 -rw-rw---- 1 mysql mysql 1073741964 2012-07-06 00:04 mysql-bin.000037 -rw-rw---- 1 mysql mysql 1073741974 2012-07-06 21:45 mysql-bin.000038 -rw-rw---- 1 mysql mysql 1073741923 2012-07-07 19:05 mysql-bin.000039 -rw-rw---- 1 mysql mysql 356167680 2012-07-07 23:47 mysql-bin.000040 my.cnf: max_binlog_size = 1073741824 log-bin = mysql-bin max_relay_log_size = 1G relay_log_space_limit = 2G mysql is creating files mysql-bin.xxxxx and my disk is full after several days. How to make mysql to delete old logs ?

    Read the article

  • FreeBSD Listen Queue Overflows - can't increase max queue size

    - by Harry
    I have a decently high trafficked FreeBSD Nginx server, and I'm starting to get a large number of listen queue overflows: [root@svr ~]# netstat -sp tcp | fgrep listen 80361931 listen queue overflows [root@svr ~]# netstat -Lan | grep "*.80" tcp4 192/0/128 *.80 [root@svr ~]# sysctl kern.ipc.somaxconn kern.ipc.somaxconn: 12288 [root@svr ~]# However I can't seem to increase the max listen queue length past 128. I've increased kern.ipc.somaxconn, but it's not changing the max. Am I missing something? Thanks!

    Read the article

  • unzip file on small drive

    - by David Oneill
    I have a zip file that contains many files. Each file in the zip file is about 100MB, and is compressed about 10% (IE it is about 90MB in the zip file). The whole zip file is 20GB, and I'm trying to unzip it onto a drive that has only 30GB free. On Windows 7, how can I unzip a zip file on my laptop's harddrive that doesn't have enough space for both the zipped and unzipped copies of the file? IE can I tell windows to remove stuff from the zip file as it is uncompressed?

    Read the article

  • Cannot open Pivot Table source file

    - by Ken
    Excel Pivot table error is: Cannot open Pivot Table source file C:\Users\UserName\AppData\Roaming\Microsoft\Excel\DatabaseName (version1).TableName I’ve seen other questions and answers with the same topic, but I think this is different. I believe I know why the error is occurring: Excel closed unexpectantly and did autosave with (version1) attached to the original file name and saved it in the C:\User etc. above , which is the default recovery location. I opened the recovered file in Excel, saved it as version1 on the server where the original file was located, deleted the original file, and renamed the version1 to the original name. When I go to PivotTable Tools? Options? Change Data Source, it shows only the Table and Range, which are correct, but it does not show the file name or path. The version1 and the renamed file both had the same structure, so the same source table was in both, by they were different files. How do I change the source file from what it is looking for to my renamed file? PS- The (version1) file that it says it is looking for is not in the autosave location, i.e. it is not at the path where it says it is looking in. Thank you for any help Ken

    Read the article

  • Officially announced RAM support size doesn't apply to one of twin rigs with just one difference

    - by Deniz
    It'll take a little long to describe my situation but here goes the story : In January 2009 we bought (the OEM parts) two similar systems with just one difference. One of them had a Phenom X4 cpu and the other one (mine) a Phenom X3 cpu. At the beginning we had problems with both systems to power them on whilst having all of their ram slots being full. We decided to install the systems with just 2 slots populated and later try to install the rest of ram sticks. Both systems did succeed to support 3 sticks. We tried many different procedures to make the systems work with their fourth ram slots being populated. We waited for new bios updates and flashed the boards when they were available, we tried different ram sticks with different frequencies etc. One day while we were trying to install the fourth stick, the X4 machine did accept it. The other one did not. The most mind boggling thing was that after one of my trials the X3 system begun to not operate with the third slot populated. Our boards did have AMD 770 chipsets and we even tried to change the board of the X3 machine with another 770 chipset board. Now my questions are : Should we change the cpu ? What is causing the X3 system to not accept the fourth (or now the third) ram stick ? The manufacturers sites do claim that this boards do accept 4 ram sticks (but they only tested them with certain ram brands and models). What are the limitations for maximum ram configurations on motherboards ? Are there some "rules of thumb" except frequency, voltage, chip type considerations for which we did check our parts ? Our boards are : Gigabyte GA-MA770-DS3 Sapphire PC-AM2RX780 - PURE CrossFireX 770

    Read the article

  • Proper 16:9 video size for non-HD 4:3 video (for youtube/vimeo)

    - by Xeoncross
    Since High Definition video came out on all the online sites it has changed the default aspect ratio of the player from 4:3 to 16:9. This means that for people posting SD video you have to resize some of your videos to get them to fit right. For example, NTSC DVD quality (aka 480i/p) is 720x480 pixels (width x height). However, low-end High Definition (720i/p) is 1280x720. Resolution Chart Anyway, now that the video players are built for HD you will find that uploading standard quality videos will result in videos that are "letter boxed" which means they have extra black bars on the top and bottom (or sides). Correct me if I'm wrong, but in order to get a 720x480 video to fit a box that is designed for HD the best practice would be to crop some of it off so that it fits as 720x404 since: 16/9 = 1.78 (1.7777777777778) 720/405 = 1.78 405x1.78 = 720.9 The same would stand for 640x480 (old TV quality) video that would need to be 640x360 correct? I'm asking because I'm not sure about all this and whether this is the proper way to fix these letter-boxing/display problems.

    Read the article

  • HOSTS ignored when disconnected [closed]

    - by Synetech
    Problem I’m seeing a strange and extremely frustrating problem. Any system that is not connect to the Internet (Windows 7 shows the no Internet access icon because it cannot constantly ping Microsoft’s servers) cannot even access locally hosted servers. Hypothesis The problem appears to be that the HOSTS file is not being used to resolve DNS entries when there are no active NICs. Tests / Reproduction You can reproduce it as so: Disconnect a system from the Internet (make sure all wired and wireless connections are disconnected). If necessary, add an entry to the HOSTS file (e.g., 127.0.0.1 foobar or 127.0.0.1 foobar.com) Open a command-prompt Type ping foobar or ping foobar.com Observations The screenshots below show a clear and demonstrative example. In the first snap, a laptop is connected to a router wirelessly. The HOSTS file has only three entries and they resolve just fine. In the second snap, the wireless radio is turned off, so the entries in the HOSTS file are ignored. Moreover, notice that pinging localhost still works even without any active NICs (as does 127.0.0.1), but it is using the IPv6 address (must be hard-coded). You can see the same results in Windows XP with no IPv6 installed, so it has nothing to do with IPv6. I tried pining what should have resolved to 127.0.0.1 while the desktop system (with no wireless NICs) was connected via its Ethernet adapter, then again after pulling the cable from the router and waiting a couple of seconds, then again after plugging the cable back in. The same thing happens if instead of pulling out the cable, the NIC is disabled through software (the [Disable] button in the NIC’s Status dialog or via Device Manager). Conclusions It looks as though the HOSTS file is only being read and used if there is an active NIC, otherwise it is being ignored. This makes some sense in that if there are no active network adapters, then presumably there will not be any network activity, and thus no need to resolve host names via the HOSTS file. This assumption is specious however because it precludes locally hosted virtual servers. The HOSTS file should be used regardless of external DNS server connectivity, otherwise you cannot use simple/consistent/testing-production names for locally hosted servers when not connected to the Internet (for example web servers; help servers for Visual Studio, 3dsmax, etc.; and so on). Question Does anyone know how to force Windows to use the HOSTS file even if there are no active NICs? Appendix Figure 1: While the wireless NIC is connected to the router (the cable-modem is in standby, so no external Internet connectivity). Figure 2: With the wireless radio turned off (the Ethernet port is not unconnected in both cases). Figure 3: Same results in XP with no IPv6

    Read the article

  • SUnreclaim size increasing in syc with a TCP-CLOSE_WAIT till application restart

    - by maver1k
    Recently found a behaviour where my application had a connection in TCP Close_wait state till the app was restarted (after about 5 hours). But during this period the SUnreclaim space was also increasing constantly and went down on restart. The application is runnning on a rhel5 os and Im not very familiar with the memory management system. Would appreciate if someone clould tell me what extactly is the Ureclaim space and why it is increasing in sync with the close_wait. Thanks.

    Read the article

  • Looping through a batch file only if the response is "everything is okay"

    - by PeanutsMonkey
    I have a batch file that loops through the contents of a directory and compresses the files in the directory as follows; for %%a in (c:\data\*.*) do if "%%~xa" == "" "C:\Program Files\7-Zip\7za.exe" a -tzip -mx9 "%%a.zip" "%%a" Seeing that I am using 7zip to compress the file, it returns the message "everything is okay" if it has successfully compressed the file and it then moves onto the next file in any. What I would like to do is the following; Only move to the next file if the response is "everything is okay" If the response is anything but "everything is okay", the error is logged Since an error has occurred, it attempts to compress the file again Once when it has succeeded i.e. "everything is okay" it goes to the next file Steps 3 & 4 only occur a maximum of 3 times before it gives up and moves onto the next file. How can I achieve this?

    Read the article

< Previous Page | 129 130 131 132 133 134 135 136 137 138 139 140  | Next Page >