  • Best way to attach 96 tb to workstation

    - by user994179
    I'm running a workstation with dual xeon 5690's (12 physical/24 logical cores), 192 gb of ram (ie, maxed-out), Windows 7 64bit, 5 slots for adapter cards, and 1 tb of internal storage, with 5 more internal bays available. I have an app that creates data files totaling about 88 tbs. These are written once every 14 months, and the rest of the time the app only needs to read them; and 95% of the reads are sequential reads of huge chunks of data. I have some control over how big the individual files are, but ideally they would be between 5 and 8 tbs. The app will be reading from only one drive at a time, and the nature of the data is such that if (when) a drive dies I can restore the data to a new disk from tape. While it would be nice to be able to use the fastest drive/controllers available, at this point size matters more than speed. After doing lots of reading, I am leaning toward buying a bunch of cheap 2tb drives and putting them into a bunch of cheap enclosures. All this stuff is going into my home office, so I need to avoid the raised floor/refrigerated approach. My questions: Is the cheap drive/enclosure solution the best one for this situation? Given the nature of the app and the way the data is used, does RAID make sense? If so, which one? For huge sequential reads, would Usb 3.0 and eSata be a wash performance-wise? For each slot available on the workstation, can I hook up an enclosure that can hold multiple drives? Or is it one controller per drive? If I can have multiple drives on one controller, am I essentially splitting the bandwidth (throughput)? For example, if I have a 12 bay enclosure, is the throughput of the controller reduced by a factor of 12? Are there any Windows 7 volume/drive/capacity limits I should be aware of? Thanks

    Read the article

  • Asus MyCinema U3100mini Choppy

    - by dsimcha
    I'm running an Asus MyCinema U3100mini ATSC on Windows 7 64-bit. When I play live TV in Windows Media Center, it's very choppy and uses 500+ MB of RAM, I'm guessing due to the hard drive buffering functionality. Is there any way to disable the live TV pause buffer completely? If not, can anyone recommend alternative software that: Works with the MyCinema. Is lightweight and not horribly bloated with features I'll never use like Windows Media Center is. Edits: This is a dual boot system. I've discovered that the tuner actually works fine on XP. It also works fine on my other computer, which has slower hardware and also runs Windows 7 64-bit. The problem actually seems to be with playback at large screen sizes, not with hard drive buffering. Everything works fine below a certain window size and fails for large windows or full screens. Also, the same thing seems to happen whether playing live or recorded TV. As far as the obvious stuff goes, I have the latest video drivers from ATI for my Radeon x1050.

    Read the article

  • 10Gbe sfp+ Cross Over Cable required? Is there such a thing?

    - by dc-patos
    To preface, this is my first experience with 10GBe networking and I have encountered an issue which research does not seem to document a solution for... I have two servers (older DL580G5 and DL380G5), each with a HP NC522SFP 10Gbe dual sfp+ port adapter. I have purchased copper "passive" direct connect adapter cables (which look like twinax), which seem to work well when I connect them to the sfp+ ports on my Dell 5524 switch. However, if I directly connect the two servers with the same cable, the link doesn't come up. I am running WS2012 standard on each server. My intention is to use one of these servers as a home brew SAN and I would like to enable mutiple 10Gbe paths for iSCSI traffic. My question(s): Can I connect the two adapters to each other, such as I would with other less speedy generations of ethernet? If I can, do I require a crossover cable, or some type of other sfp+ cable solution to do this? My 10Gbe sfp+ switch ports are premium, but server to server connections are doable in small numbers for me and I would really like the multiple paths this would give me. Is there a simple solution?

    Read the article

  • vmware vmdk disk problem

    - by dmtr
    Hello, I have a vmware esxi 4 server and 2 storage servers (mount as nfs). Between the storage servers (fedora 14) is made drbd cluster (dual primary) and ocfs2 filesystem, also every server has local partition with ext4 filesystem, both are mounted as nfs on esxi server. When i tried to copy a virtual machine (naturally it power off) files from ext4 partition to ocfs2 partition, vmdk total file size is different, but md5sum is the same. on ext4 partition: # ls -la total 28492228 -rw------- 1 root root 42949672960 Jan 14 14:46 disk-flat.vmdk # md5sum disk-flat.vmdk 0eaebe3138beb32f54ea5de6dfe5a987 on ocfs2 partition: # ls -la total 13974660 -rw------- 1 root root 42949672960 Jan 14 16:16 disk-flat.vmdk # md5sum disk-flat.vmdk 0eaebe3138beb32f54ea5de6dfe5a987 When i power on the virtual machine from ocfs2 partition it dosn't work. I have a windows on the virtual machine and it freez?s after windows logo. From ext4 partition the virtual machine is worked. Test with linux (create and install on ext4 partition and copy) the same problem appears. When i create a virtual machine directly from ocfs2 partition, there are no problems. I tried to copy via vSphere client, and i have the same problem. Any suggestions ?

    Read the article

  • Cross OS data recover question, USB drive involved.

    - by Moshe
    Here's the story: A MacBook had OS X 10.4 and Windows XP dual booting using rEFIt. Then the Windows partition gets corrupted and it won't boot. Presumably a virus. There were sensitive files there and those were successfully copied to a USB drive and then 10.5 was installed on the hard drive, formatting the drive in the process. The USB drive's contacts cracked and he data is lost from there, unless it can be resoldered. The issues is that there is too much solder there already. So, how can the data in question be recovered? The files were Microsoft Money (not the latest version) files for the Windows version of the program. Right now, only OS X is installed on the MacBook. Is there Mac based program that can recover the Windows data or am I better off trying to resolder the drive? Does anyone know how to best resolder a USB drive more than once, where the first solder is ther, but detached from the silicon? Also, what format (extension) are Microsoft Money files? In need of help!

    Read the article

  • Cannot install CentOS 6.5 using UEFI usb boot

    - by Vaindil
    I am trying to dual-boot CentOS 6.5 on my desktop that is currently running Windows 8.1. I have two storage devices: an SSD that has my Windows installation, and an HDD that has all of my data. Both are formatted using GPT, and Windows boots using UEFI. I used the CentOS 6.5 live DVD (CentOS-6.5-x86_64-LiveDVD.iso) to create an EFI-bootable flash drive (it does boot properly in EFI mode). I receive an error, however, when CentOS is booting (error is below). I have a 6.4 boot DVD which boots as expected, but it does not boot in UEFI mode and therefore doesn't play nicely with my Windows installation (I have no way to access it, even using rEFInd or any other similar tools). What do I need to do to get the device to boot properly in UEFI mode? Kernel panic - not syncing: Attempted to kill init! Pid: 1, comm: init Not tainted 2.6.32-431.el6.x86_64 #1 Call Trace: [<ffffffff815271fa>] ? panic+0xa7/0x16f [<ffffffff81077622>] ? do_exit+0x862/0x870 [<ffffffff8118a865>] ? fput+0x25/0x30 [<ffffffff81077688>] ? do_group_exit+0x58/0xd0 [<ffffffff81077717>] ? sys_exit_group+0x17/0x20 [<ffffffff8100b072>] ? system_call_fastpath+0x16/0x1b drm_kms_helper: panic occurred, switching back to text console

    Read the article

  • Are These Parts compatible?

    - by ell
    I have never assembled a PC before, although I have taken an old one apart and replaced a few parts in others here and there so I have (very) limited experience. I have been looking to make a pc and here are the parts I might buy: Foxconn P45AL Intel P45 (Socket 775) DDR2 Motherboard (with onboard sound I believe) Gigabyte GeForce GTX 460 OC 768MB GDDR5 PCI-Express Graphics Card Already have 2 1gb sticks of dual channel DDR2 memory Intel Core 2 Quad Q8400 LGA775 'Yorkfield' 2.66GHz 4MB-cache Processor Samsung SpinPoint F3 1TB SATA-II 32MB Cache Hard Drive Antec Dark Fleet Series DF10 Gaming Enclosure – Black I already have monitor, mouse, keyboard and DVD/CD drive Akasa Freedom Power 1000W Modular Power Supply I have never done this before so feel free to laugh at me for getting something obvious wrong, forgetting a vital component etc. but is all of this compatible? And have I gone overkill on the PSU, if so, please recommend one. Thanks in advance, ell. EDIT: Added PSU which I forgot to mention EDIT: I would be using this to surf the internet, write e-mails, chat, word process, play games such as team fortress 2 & spring rts (at highest graphics hopefully), some 3d modelling in blender, some opengl programming, and image editing in GIMP.

    Read the article

  • mysql INNODB inserts very slow

    - by 133794m3r
    The database's schema is as follows. CREATE TABLE `items` ( `id` mediumint( 8 ) unsigned NOT NULL AUTO_INCREMENT , `name` varchar( 45 ) NOT NULL , `main_type` tinyint( 4 ) NOT NULL , `rarity` tinyint( 4 ) NOT NULL , `stack_size` smallint( 6 ) NOT NULL , `sub_type` tinyint( 4 ) NOT NULL , `cost` mediumint( 8 ) unsigned NOT NULL , `ilvl` smallint( 6 ) unsigned NOT NULL DEFAULT '0', `flavor_text` varchar( 250 ) NOT NULL , `rlvl` tinyint( 3 ) unsigned NOT NULL , `final` tinyint( 4 ) NOT NULL DEFAULT '0', PRIMARY KEY ( `id` ) ) ENGINE = InnoDB DEFAULT CHARSET = ascii; Now, doing an insert on this table takes 0.22 seconds. I don't know why it's taking so long to do a single row insert. Reads are really really fast something like 0.005 seconds. With using the example configuration from here dev mysql innodb it averages ~0.002 to ~0.005 seconds. Why it takes more than 100x more time to do a single insert makes no sense to me. My computer is as follows. OS:Debian Sid x86-x64, Mysql 5.1, RAM:4GB ddr2, cpu 2.0Ghz dual core, HDD 7200RPM 32MB cache 640GB. Why it's taking almost 100x as much time for a SELECT * FROM items; vs INSERT INTO items ...; will never make any sense to me. It's still a small table at only 70 rows, and took that long even when it had 0 rows.

    Read the article

  • Google Chrome warning that Javascript is disabled

    - by kirchoffs415
    I hope somebody can help. I keep getting the following message when I log on: Your Javascript is disabled. Limited functionality is available. It will stay for maybe a day sometimes two. I have uninstalled javascript and reinstalled but still the same. I am using chrome. Any help would be grateful many thanks Dominic My system spec is as follows System InformationOS Name Microsoft® Windows Vista™ Home Premium Version 6.0.6002 Service Pack 2 Build 6002 Other OS Description Not Available OS Manufacturer Microsoft Corporation System Name DOM-PC System Manufacturer Dell Inc. System Model Inspiron 1545 System Type X86-based PC Processor Pentium(R) Dual-Core CPU T4200 @ 2.00GHz, 2000 Mhz, 2 Core(s), 2 Logical Processor(s) BIOS Version/Date Dell Inc. A05, 25/02/2009 SMBIOS Version 2.4 Windows Directory C:\Windows System Directory C:\Windows\system32 Boot Device \Device\HarddiskVolume3 Locale United Kingdom Hardware Abstraction Layer Version = "6.0.6002.18005" User Name DOM-PC\DOM Time Zone GMT Standard Time Installed Physical Memory (RAM) 3.00 GB Total Physical Memory 2.96 GB Available Physical Memory 1.38 GB Total Virtual Memory 5.89 GB Available Virtual Memory 4.25 GB Page File Space 3.00 GB Page File C:\pagefile.sys My System Specs

    Read the article

  • Troubleshooting a Windows 7 PC that wouldn't sleep

    - by NPE
    I have a new Windows 7 PC that wouldn't sleep (not just automatically, but also when specifically told to). The screen goes black momentarily, but within two seconds the machine comes back as if nothing has happened. I tried powercfg energy. This produces some errors quoted at the bottom of this post, plus some warnings about timer resolution. There are no USB devices connected other than wireless keyboard + mouse (Logitech MK250); I tried unplugging them to no effect. The motherboard is Asus P7P55D-E. powercfg lastwake says "Wake History Count - 0", which I take to mean that it never actually went to sleep. I dual boot into Ubuntu, and was having exactly the same problem on the Linux side. That turned out to do with USB 3.0, which I've now disabled in the BIOS. This has solved the problem on the Ubuntu side of things, but made no difference to Windows 7. Any suggestions? Suspend:USB Device not Entering Suspend The USB device did not enter the Suspend state. Processor power management may be prevented if a USB device does not enter the Suspend state when not in use. Device Name Generic USB Hub Host Controller ID PCI\VEN_8086&DEV_3B34 Host Controller Location PCI bus 0, device 29, function 0 Device ID USB\VID_8087&PID_0020 Port Path 1 USB Suspend:USB Device not Entering Suspend The USB device did not enter the Suspend state. Processor power management may be prevented if a USB device does not enter the Suspend state when not in use. Device Name USB Root Hub Host Controller ID PCI\VEN_8086&DEV_3B34 Host Controller Location PCI bus 0, device 29, function 0 Device ID USB\VID_8086&PID_3B34 Port Path USB Suspend:USB Device not Entering Suspend The USB device did not enter the Suspend state. Processor power management may be prevented if a USB device does not enter the Suspend state when not in use. Device Name USB Composite Device Host Controller ID PCI\VEN_8086&DEV_3B34 Host Controller Location PCI bus 0, device 29, function 0 Device ID USB\VID_046D&PID_C52E Port Path 1,8

    Read the article

  • Virtual machines with failover setup

    - by kimmmo
    We have three servers and our plan is to run a number of virtual machines on them in such manner, that if one of the nodes blow up, we can either quickly or seamlessly get a spare running on another node. In addition to the normal networking, they're interconnected via dual 10Gbit NIC's, so networked raid/mirroring shouldn't be a problem. The guest VM's are mostly going to be running text mode linux, but of course it wouldn't hurt to be able to spin up a non-mission critical windows guest for running Visual Studio or checking IE compatibility of a web app. We've spent some time trying to get some magical cloud setup running using Stackops and Crowbar but it started to look like they were offering way too much and were too complicated for our needs. The next candidate, I think, is Ubuntu 11.04 server + KVM + Ganeti + Drbd, unless you can come up with a suggestion for a better solution that we have missed. Requirements: Installation should be simple or at least understandable without being in the dev team A browser interface for creating and managing VM's is a nice bonus Single node's hardware failure should cause minimal downtime for VM's that were running on that node Adding more nodes should be possible without shutting down the VM's.

    Read the article

  • sata hard drive failed

    - by M. Shehryar
    Dear friend, initially my dual core PC started shutdown and re-start by itself after adding 1 GB ram and up-grading the graphic card. Then refused to boot. I restored the window ghost but failed to boot. I tried to install new window but installation failed after coping the window files. tried to install old vista lonhorn. It inspected found errors, fixed them but ultimatly failed to be installed. Once again restored the ghost through acronis but failed to boot. At the end attached as slave with another pc but it was not visible. Even acronis could not see it or its partitions. Only bios can see it. It seems that no file system is available on the drive. My data on drive is very important. Please help me how to revover my data. Drive brand is Samsung, cap is 160 GB and file system was NTFS.

    Read the article

  • sata hard drive failed

    - by M. Shehryar
    Dear friend, initially my dual core PC started shutdown and re-start by itself after adding 1 GB ram and up-grading the graphic card. Then refused to boot. I restored the window ghost but failed to boot. I tried to install new window but installation failed after coping the window files. tried to install old vista lonhorn. It inspected found errors, fixed them but ultimatly failed to be installed. Once again restored the ghost through acronis but failed to boot. At the end attached as slave with another pc but it was not visible. Even acronis could not see it or its partitions. Only bios can see it. It seems that no file system is available on the drive. My data on drive is very important. Please help me how to revover my data. Drive brand is Samsung, cap is 160 GB and file system was NTFS.

    Read the article

  • MD RAID 1 with external bitmap doesn't fully resync

    - by user64744
    I have an interesting configuration: dual boot system with a RAID 1 that needs to be visible in both Windows and Linux. The Windows install is Win 7 Enterprise, and the Linux install is Kubuntu 10.04. To get the RAID to work, I set it up using Windows's "Dynamic Disks" RAID 1, and brought it up in Linux using MD with no persistent superblock, and a write-intent bitmap on another partition. (Without this bitmap, MD had no way of knowing that the array was in sync, and would do a complete resync every time the array started.) The array is assembled like so: mdadm --build /dev/md1 -l 1 -n 2 -b /var/local/md1.bitmap /dev/sdb2 /dev/sdc2 I expected that the first time I ran this command, it would resync the array, write out a bitmap with no dirty chunks, and all would be good. This wasn't the case: after completing the resync, the bitmap was mostly clean, but about 5% dirty blocks remained, as revealed by mdadm -X /var/local/md1.bitmap I didn't mount the filesystem on /dev/md1 or touch it in any other way. I then found that stopping and restarting the array: mdadm --stop /dev/md1 mdadm --build /dev/md1 -l 1 -n 2 -b /var/local/md1.bitmap /dev/sdb2 /dev/sdc2 did indeed read in the bitmap, with an ensuing resync that went quickly because most of the blocks were marked clean. The confusing part is that this resync further reduced the number of dirty blocks, but still did not remove all of them. By repeatedly stopping and restarting I could slowly bring the dirty block count down to around 0.6%, where it seemed to level out. Any ideas what could be causing this? It smells to me of a race condition somewhere that leads to blocks either being skipped over during synchronization or not properly cleared from the bitmap, but I really have no evidence to prove this. It doesn't look like hardware issues since both drives are new and have zero read errors and reallocated sectors reported by smartctl -a.

    Read the article

  • GA 8KNXP Rev1.0: 4GB installed, only 3.5 recognized by BIOS

    - by hurikhan77
    I've installed 2x 1 GB and 4x 512 MB memory into my GA-8KNXP system which would sum up to 4GB. The specs from the manual say: Maximum memory support: 4GB. If all six slots are utilized, slot 5+6 may only equipped with single-sided RAM modules. And so I did. Anyway: The BIOS counts up to 3.5 GB and finishes there. Also my linux system reports only 3.5 GB of memory although 4 GB memory support is activated in the kernel. So I suppose this is a memory mapping issue or a hardware issue. I've tried removing only on of the 512 MB memory modules leaving 5 modules in place. But that just stopped the system from powering on correctly (screen stays black although fans and leds come to live). Dual Channel was detected and enabled so the system technically found all 6 modules. "dmidecode" in linux reports only memory in slots 1 to 4 and ignores slots 5+6, so it only detects 3 GB of memory. It also says the system would support up to 16 GB of memory with 4 GB modules per slot. I think technically the chipset should be able to offer and utilize the complete 4 GB memory range. Any clues what else I could check? Or do I have just to live with 0.5 GB wasted memory?

    Read the article

  • How can I make sound work without starting X?

    - by Magnus Hoff
    I have a headless machine connected to my sound system, and I am using it to run a music playing daemon that I control over the network. (Among other things) However, I can't seem to be able to have sound come out of my speakers without running X. I am running pulse audio in a system wide instance and my daemon is not running within X. Nevertheless, when my daemon is playing music without me hearing it, I can fix it by running startx in an unrelated session. After X starts, I can hear the sound. The sound disappears again if I kill the X server. Interestingly/annoyingly, the sound also stops after X has been running for a few minutes. This could possibly be because of a screen saver of some sort, but I haven't been able to verify or falsify this theory. So my current workaround is to ssh into the box whenever I want music and startx, and restart it every fifteen minutes or so. I'd like to do better. I have been able to verify the following: Adjustments in alsamixer have no effect on this problem. The relevant output channel is never muted In alsamixer, I can see no difference between when the sound is working and when it isn't Nothing is muted in pactl list There is no difference in the output from pactl list between before starting X and after it's started. (Except the identifier of the pactl instance connected to pulse, which is different each time you run pactl) The user running the music daemon is a member of the groups audio, pulse and pulse-access The music daemon program does not report any error messages and acts as if it is playing the music like it should Some form of dbus daemon is running. ps aux|grep dbus reports dbus-daemon --system --fork --activation=upstart before and after I have started X Some details about my hardware: Motherboard: http://www.asus.com/Motherboards/AT5IONTI_DELUXE/ Sound chip: Nvidia GPU 0b HDMI/DP (from alsamixer) Using HDMI for output (Machine also has an Intel Realtek ALC887 that I am not using) Output of lsmod: Module Size Used by deflate 12617 0 zlib_deflate 27139 1 deflate ctr 13201 0 twofish_generic 16635 0 twofish_x86_64_3way 25287 0 twofish_x86_64 12907 1 twofish_x86_64_3way twofish_common 20919 3 twofish_generic,twofish_x86_64_3way,twofish_x86_64 camellia 29348 0 serpent 29125 0 blowfish_generic 12530 0 blowfish_x86_64 21466 0 blowfish_common 16739 2 blowfish_generic,blowfish_x86_64 cast5 25112 0 des_generic 21415 0 xcbc 12815 0 rmd160 16744 0 bnep 18281 2 rfcomm 47604 12 sha512_generic 12796 0 crypto_null 12918 0 parport_pc 32866 0 af_key 36389 0 ppdev 17113 0 binfmt_misc 17540 1 nfsd 281980 2 ext2 73795 1 nfs 436929 1 lockd 90326 2 nfsd,nfs fscache 61529 1 nfs auth_rpcgss 53380 2 nfsd,nfs nfs_acl 12883 2 nfsd,nfs sunrpc 255224 16 nfsd,nfs,lockd,auth_rpcgss,nfs_acl btusb 18332 2 vesafb 13844 2 pl2303 17957 1 ath3k 12961 0 bluetooth 180153 24 bnep,rfcomm,btusb,ath3k snd_hda_codec_hdmi 32474 4 nvidia 11308613 0 ftdi_sio 40679 1 usbserial 47113 6 pl2303,ftdi_sio psmouse 97485 0 snd_hda_codec_realtek 224173 1 snd_hda_intel 33719 5 snd_hda_codec 127706 3 snd_hda_codec_hdmi,snd_hda_codec_realtek,snd_hda_intel serio_raw 13211 0 snd_seq_midi 13324 0 snd_hwdep 17764 1 snd_hda_codec snd_pcm 97275 3 snd_hda_codec_hdmi,snd_hda_intel,snd_hda_codec snd_rawmidi 30748 1 snd_seq_midi snd_seq_midi_event 14899 1 snd_seq_midi snd_seq 61929 2 snd_seq_midi,snd_seq_midi_event snd_timer 29990 2 snd_pcm,snd_seq snd_seq_device 14540 3 snd_seq_midi,snd_rawmidi,snd_seq snd 79041 20 snd_hda_codec_hdmi,snd_hda_codec_realtek,snd_hda_intel,snd_hda_codec,snd_hwdep,snd_pcm,snd_rawmidi,snd_seq,snd_timer,snd_seq_device asus_atk0110 18078 0 mac_hid 13253 0 jc42 13948 0 soundcore 15091 1 snd snd_page_alloc 18529 2 snd_hda_intel,snd_pcm coretemp 13554 0 i2c_i801 17570 0 lp 17799 0 parport 46562 3 parport_pc,ppdev,lp r8169 62154 0 Any ideas? What does X do that's so important?

    Read the article

  • What laptop would be recommended for video-editing or transcoding to blu-ray?

    - by Rob
    I'm looking for a machine (has to be a laptop) reasonably fast enough to handle editing/transcoding/rendering to Blu-ray disc of full true HD 1080p (1920x1080) video from a Samsung R10 camcorder - MPEG4 25fps (not the Sony-Panasonic AVCHD format): To be able to browse through the footage (say, quarter screen is fine for monitoring) and do simple edits - cut out bad bits, add titles, fades, nothing too fancy To be able to burn the footage in 1920x1080p 24p (twenty-four) fps to blu-ray, probably don't mind if I have to leave it for a few hours, or even overnight, as long as its not still running in the morning or takes days. I ALREADY have an external USB 2.0 LG BE06LU10 blu-ray burner. Does quad core make much difference? Or would Dual-core suffice for the above? NVidia because of CUDA for increased speed. What software today can take advantage of this? Which graphics card do I need? So far I've found Dell/Alienware to be well-specified, having a 5yr old Dell laptop that still runs well, albeit slow by today's standards, gives me a good impression. My concerns are too much fan-noise and budget and some Dell Precision Laptops exceed 1500 pounds. Thoughts?

    Read the article

  • Should I partition a 1TB Hard Disk whose primary use is media storage?

    - by Senthil
    I am going to get a 1TB hard disk. I will be storing 1080p or 720p movies, high-bitrate music and pictures in it. I use my PC 90% of the time only to play/listen/see those. I am running out of space in my current HD so I am getting another one. My specs are 2.7GHz Dual Core, 512MB GeForce 9400GT, 2GB DDR2 RAM and all the proper matroska codecs/players. I guess that is enough to play 1080p movies withough a glitch, given an ideal hard disk. I've read about proper partitioning giving performance improvement etc.. I don't want my hard disk to be the bottleneck. Can someone tell me whether I should partition my 1TB hard disk into many drives? If I should, what is the ideal size of each partition? Smooth playing of movies is very important to me. Once I start filling up the disk, there is no turning back. So I want to get it right before I start. Thanks.

    Read the article

  • Home Server: cpu virtualisation, what to choose?

    - by Huygens
    I'm looking for virtualisation solutions for storage and OS for a home server. A sort of private cloud where I manage the storage space independently of the VM one. This question focus on VM (or compute instance) management and what would best suit my needs. (I have another question related to the storage management). My use cases are: A backup server: rsync and other services running. A personal cloud server: a kind of owned dropbox system, à la ownCloud. " users foreseen. A media server: streaming videos and displaying photos. Here my environement and wishes: Server: HP Proliant MicroServer with 8 GB RAM (AMD Turion dual core with AMD-V technology) OS types: only Linux (perhaps a *BSD VM in the future) Linux distributions do not matter, I'm familiar with RHEL, Fedora, Suse, Ubuntu, but any other recommandation will be fine 2-3 VMs foreseen: backup server, owncloud server and media server (optional). Those are only servers, so no graphical console needed (I don't need VirtualBox) By VM I mean a virtualised environment like KVM, Xen, etc. or a compute instance like with OpenStack storage should be "virtualised/cloudified" see my other question. VM should be able to be migrated to another server in the future if performance cannot be fullfilled anymore by the current server It does not matter if installation of such setup is complicated as long as management tools allow for easy maintenance I don't have Windows at home, so solution should be Linux friendly and would be nice to be web based. But native apps are OK too. System should be easy to enhance: by adding a new server to migate some of the VMs to it. So it's really a kind of private cloud on which I could run some Linux OS. I would prefer free (libre, as in a free speach) and open source tools. But it does not have to be free as in a free beer. So Xen, KVM, VitualBox or OpenStack? What would you recommend?

    Read the article

  • How to edit known_hosts when several hosts share the same IP and DNS name?

    - by Frédéric Grosshans
    I regularly ssh into a computer which is a dual-boot OS X / Linux computer. The two OS instance do not share the same host key, so they can be seen as two host sharing the same IP and DNS. Let's say the IP is 192.168.0.9, and the names are hostname and hostname.domainname As far as I understood, the solution to be able to connect to the two host is to add them both to the ~/.ssh/know_hosts file. However, it is easier said than done, because the file is hashed, and has probably several entries per host (192.168.0.9, hostname, hostname.domainname). As a consequence, I have the following warning Warning: the ECDSA host key for 'hostname' differs from the key for the IP address '192.168.0.9' Is there an easy way to edit the known_hosts file, while keeping the hashes. For example, how can I find the lines corresponding to a given hostame? How can I generate the hashes for some known hosts? The ideal solution would allow me to connect to seamlessly to this computer with ssh, no matter whether I call it 192.168.0.9, hostname or hostname.domainname, nor if it uses its Linux hostkey or its OSX hostkey. However, I still want to receive a warning if there is a real man-in-the middle attack, i.e. if another key than these two is used.

    Read the article

  • ZFS with L2ARC (SSD) slower for random seeks than without L2ARC

    - by Florian Kruse
    I am currently testing ZFS (Opensolaris 2009.06) in an older fileserver to evaluate its use for our needs. Our current setup is as follows: Dual core (2,4 GHz) with 4 GB RAM 3x SATA controller with 11 HDDs (250 GB) and one SSD (OCZ Vertex 2 100 GB) We want to evaluate the use of a L2ARC, so the current ZPOOL is: $ zpool status pool: tank state: ONLINE scrub: none requested config: NAME STATE READ WRITE CKSUM afstank ONLINE 0 0 0 raidz1 ONLINE 0 0 0 c11t0d0 ONLINE 0 0 0 c11t1d0 ONLINE 0 0 0 c11t2d0 ONLINE 0 0 0 c11t3d0 ONLINE 0 0 0 raidz1 ONLINE 0 0 0 c13t0d0 ONLINE 0 0 0 c13t1d0 ONLINE 0 0 0 c13t2d0 ONLINE 0 0 0 c13t3d0 ONLINE 0 0 0 cache c14t3d0 ONLINE 0 0 0 where c14t3d0 is the SSD (of course). We run IO tests with bonnie++ 1.03d, size is set to 200 GB (-s 200g) so that the test sample will never be completely in ARC/L2ARC. The results without SSD are (average values over several runs which show no differences) write_chr write_blk rewrite read_chr read_blk random seeks 101.998 kB/s 214.258 kB/s 96.673 kB/s 77.702 kB/s 254.695 kB/s 900 /s With SSD it becomes interesting. My assumption was that the results should be in worst case at least the same. While write/read/rewrite rates are not different, the random seek rate differs significantly between individual bonnie++ runs (between 188 /s and 1333 /s so far), average is 548 +- 200 /s, so below the value w/o SSD. So, my questions are mainly: Why do the random seek rates differ so much? If the seeks are really random, they should not differ much (my assumption). So, even if the SSD is impairing the performance it should be the same in each bonnie++ run. Why is the random seek performance worse in most of the bonnie++ runs? I would assume that some part of the bonnie++ data is in the L2ARC and random seeks on this data performs better while random seeks on other data just performs similarly like before.

    Read the article

  • Monitor displays at 1024x768; scrolls screen for higher resolutions

    - by Matt
    I have a dual monitor setup. Normally, they both display at 1680x1050. They have been setup this way for about a year. I'm using Windows XP Professional 2003 x64 SP2. Today, out of nowhere, one of the monitors kicked back to a lower resolution. I was not playing with any configuration at the time.. in fact all I had done was close a window (maybe a browser). But the thing is that the resolution is still preserved partially by the fact that the screen will scroll when you move the mouse. So it's like looking through a 1024x768 window into a 1680x1050 world. The monitor itself does not appear to be damaged, because I also have it connected to my netbook (via KVM) and higher resolutions work fine. I tried uninstalling/reinstalling the drivers to no avail. System restore doesn't help either. I'm unsure of the exact ATI card I'm using.. Device Manager lists it as "Radeon X300/X550/X1050". There is no Catalyst Control Center software installed. I tried to install it, but there doesn't seem to be a way to install it by itself ... it forces you to install another driver, which breaks both of my displays, forcing me to go into safe mode and run system restore again. Any ideas? Thanks

    Read the article

  • How to Log Into a Web App Simultaneously with Different Account?

    - by Ngu Soon Hui
    I want to log into a web application, using at least ten account names at one single point of time ( I am not trying to do anything illegal, so don't worry). AFAIK, each tab in Chrome will share the same session, therefore, for one machine, one can use Google Chrome to log in at most 2 accounts, one in normal mode, another in Incognito mode. Is there anyway I can log into multiple accounts? I know I can open up IE and Firefox ( probably Safari etc) and login, but this is not really scalable as the number of web browsers is finite. Edit: My application is a localhost application; it resides on my computer. So proxy may not be that useful, and you now probably understand why it's nothing illegal. Edit2: CookieSwap seems like a good idea, but the problem is that once I swap the cookie, all the tabs and the FF apps' cookie are swap as well. Can the swapping be done on a tab basis or on application basis, so that on a dual-monitor, I can see the different login side-by-side?

    Read the article

  • bootmgr image is corrupt

    - by bacord
    I just replaced my HD with a SSD. I did a brand new install on the SSD and I received the following error after booting BOOTMGR image is corrupt. The system cannot boot. A little configuration for your knowledge. The system used to be a dual boot with XP & windows 7. After replacing the original startup HD with my SSD I changed a setting in the bios to AHCI (I have tested changing it back but this did not help). When I look at the stats on the drive in the bios, it claims that the SSD is in a raid configuration despite the settings not being configured that way. Related System Information: Intel 320 Series 80 GB Sata II SSD JetWay JPA78VM3-H-LF AM2+/AM2 AMD 780V HDMI Micro ATX AMD Motherboard AMD Athlon 64 X2 7 GB ram I have performed 2 fresh installs to no avail. Also, followed this guide and performed option 1 and 2. I have done bootsec/fixmbr and /fixboot. So.. any suggestions?

    Read the article

  • DNS failover in a two datacenter scenario

    - by wanson
    I'm trying to implement a low-cost solution for website high availability. I'm looking for the downsides of the following scenario: I have two servers with the same configuration, content, mysql replication (dual-master). They are in different datacenters - let's call them serverA and serverB. Users use serverA - serverB is more like a backup. Now, I want to use DNS failover, to switch users from serverA to serverB when serverA goes down. My idea is that I setup DNS servers (bind/powerdns) on serverA and serverB - let's call them ns1.website.com and ns2.website.com (assuming I own website.com). Then I configure my domain to use them as its nameservers. Both DNS servers will return serverA IP as my website's IP. If serverA goes down I can (either manually or automatically from serverB) change configuration of serverB's DNS, to return IP of serverB as website's IP. Of course the TTL will be low, as it's supposed to be in DNS failovers. I know that it may take some time to switch to serverB (DNS ttl, time to detect serverA failure, serverB DNS reconfiguration etc), and that some small part of users won't use serverB anyway. And I'm OK with that. But what are other downsides of such an approach? An alternative scenario is that ns1.website.com will return serverA IP as website's IP, and ns2.website.com will return serverB IP as website's IP. But AFAIK clients not always use primary nameserver and sometimes would use secondary one. So some small part of users would use serverB instead of serverA which is not quite what I'd like. Can you confirm that DNS clients behave like that and can you tell what percentage of clients would possibly use serverB instead of serverA (statistically)? This one also has the downside that when serverA goes back up, it will be automatically used as website's primary server, which is also a bad situation (cold cache, mysql replication could fail in the meantime etc). So I'm adding it only as a theoretical alternative. I was thinking about using some professional DNS failover companies but they charge for the number of DNS requests and the fees are very high (why?)

    Read the article