Search Results

Search found 21539 results on 862 pages for 'hanging process'.

Page 16/862 | < Previous Page | 12 13 14 15 16 17 18 19 20 21 22 23  | Next Page >

  • Any tool(s) for knowing the layout (segments) of running process in Windows?

    - by claws
    I've always been curious about How exactly the process looks in memory? What are the different segments(parts) in it? How exactly will be the program (on the disk) & process (in the memory) are related? My previous question: http://stackoverflow.com/questions/1966920/more-info-on-memory-layout-of-an-executable-program-process In my quest, I finally found a answer. I found this excellent article that cleared most of my queries: http://www.linuxforums.org/articles/understanding-elf-using-readelf-and-objdump_125.html In the above article, author shows how to get different segments of the process (LINUX) & he compares it with its corresponding ELF file. I'm quoting this section here: Courious to see the real layout of process segment? We can use /proc//maps file to reveal it. is the PID of the process we want to observe. Before we move on, we have a small problem here. Our test program runs so fast that it ends before we can even dump the related /proc entry. I use gdb to solve this. You can use another trick such as inserting sleep() before it calls return(). In a console (or a terminal emulator such as xterm) do: $ gdb test (gdb) b main Breakpoint 1 at 0x8048376 (gdb) r Breakpoint 1, 0x08048376 in main () Hold right here, open another console and find out the PID of program "test". If you want the quick way, type: $ cat /proc/`pgrep test`/maps You will see an output like below (you might get different output): [1] 0039d000-003b2000 r-xp 00000000 16:41 1080084 /lib/ld-2.3.3.so [2] 003b2000-003b3000 r--p 00014000 16:41 1080084 /lib/ld-2.3.3.so [3] 003b3000-003b4000 rw-p 00015000 16:41 1080084 /lib/ld-2.3.3.so [4] 003b6000-004cb000 r-xp 00000000 16:41 1080085 /lib/tls/libc-2.3.3.so [5] 004cb000-004cd000 r--p 00115000 16:41 1080085 /lib/tls/libc-2.3.3.so [6] 004cd000-004cf000 rw-p 00117000 16:41 1080085 /lib/tls/libc-2.3.3.so [7] 004cf000-004d1000 rw-p 004cf000 00:00 0 [8] 08048000-08049000 r-xp 00000000 16:06 66970 /tmp/test [9] 08049000-0804a000 rw-p 00000000 16:06 66970 /tmp/test [10] b7fec000-b7fed000 rw-p b7fec000 00:00 0 [11] bffeb000-c0000000 rw-p bffeb000 00:00 0 [12] ffffe000-fffff000 ---p 00000000 00:00 0 Note: I add number on each line as reference. Back to gdb, type: (gdb) q So, in total, we see 12 segment (also known as Virtual Memory Area--VMA). But I want to know about Windows Process & PE file format. Any tool(s) for getting the layout (segments) of running process in Windows? Any other good resources for learning more on this subject? EDIT: Are there any good articles which shows the mapping between PE file sections & VA segments?

    Read the article

  • COM Pointers and process termination

    - by Tony
    Can an unreleased COM pointer to an external process (still alive) cause that process to hang on destruction? Even with TerminateProcess called on it? Process A has a COM interface pointer reference to Process B, now Process B issues a TerminateProcess on A, if some COM interface pointer to Process B in Process A is not released properly, could it be that the process hangs on termination?

    Read the article

  • Troubleshooting an NFS server hanging after authenticated mount request

    - by Christoph
    I need some advice on troubleshooting an NFS server problem on Scientific Linux (RHEL) 6.1. The log on the server shows that an authenticated mount request was made: Jan 13 16:30:02 ??? rpc.mountd[3996]: authenticated mount request from ????:784 for /shared-storage/cm/shared (/shared-storage/cm/shared) But after that, it does not continue. On the client, it is also hanging. The interesting thing now is that I have two NFS servers, which should be identical, and the one is working perfectly, but the other exhibits the above mentioned behaviour. The problem is also not completely persistent, i. e. sometimes the mount request succeeds. I assume that the problem must be related to the server rather than to the client, because it is working perfectly on the other server. My question is where I should search the problem. I have already re-created the exports using exportfs -r, I have restarted the NFS server, I have compared the rpcinfo outputs of both server - no success. The problem even survives a reboot. Any other ideas are appreciated. As answer to Tim's question: I have sporadically the following in dmesg, but do not know whether it is related e1000e 0000:0c:00.0: eth4: Detected Hardware Unit Hang: TDH <24> TDT <25> next_to_use <25> next_to_clean <24> buffer_info[next_to_clean]: time_stamp <1c3d12940> next_to_watch <24> jiffies <1c3d12940> next_to_watch.status <0> MAC Status <80383> PHY Status <792d> PHY 1000BASE-T Status <7800> PHY Extended Status <3000> PCI Status <10> Further edit: The problem above does not occur on the machine that is working, so it probably is related. Again an edit: The error is not on the (software) device that is used for NFS, but on another one. The NFS mount also does not trigger the message.

    Read the article

  • How to establish a two-way communication between Activity and Service in different process?

    - by steff
    Hi everyone, I'm working on establishing a two-way communication between an Activity and a Service which runs in a different process. Querying the process from the Activity is no big deal. But I want the process to notify the Activity on events. The idea behind it is this: the service runs independently from the actual app. It queries a webserver periodically. If a new task is found on the webserver the process should notify the activity. I found this thread over at AndDev.org but it doesn't seem to work for me. I've been messing around with BroadcastReceiver. I've implemented an interface which should notify the Activity but the problem is that the listener is always null since the Broadcast from the process is done via Intent, hence the class that extends BroadcastReceiver will be newly instantiated. How can I establish a 2-way communication? This has to be possible. Thanks for any help, steff

    Read the article

  • IE9 development tools giving "Unable to attach to the process." error

    - by Urbycoz
    Notice: I have now rebuilt my machine to remove this bug, so I can no longer verify any answers. I recently installed Internet Explorer 9, and activated the development tools by pressing F12; I then clicked "script" and the "start debugging" button but I got the following error: Unable to attach to the process. Another debugger might be attached to the process. I get this message regardless of the site I am on (currently I'm on google.com). I have no other applications running, and have rebooted my machine. Can anyone suggest why this may be appearing?

    Read the article

  • How to set a low process priority for everything spawned from a command prompt in XP?

    - by Binary Worrier
    As a developer, once or twice a week I run a full build on my XP dev machine. This will run at 100% cpu for 30 or 40 minutes, making my machine usless for anything other than basic browsing & email. Is there anyway I can specify that for a given process (i.e. a command prompt) it and any process spawned by it will hae a lower priority, say taking up no more than 60 - 70% of CPU, leaving my machine more usable. I don't mind the build talking 30 or 40% longer, if I still have use of my machine while it's running. Thanks BW P.S. I'd love to be able to throw more hardware at the problem, but that isn't under my control.

    Read the article

  • Total network data sent/received of a non-daemon Linux process?

    - by leden
    I'm looking for a simple and effective way of measuring total bytes received/sent from a single process upon its termination. Basically, I am looking for a tool which has the interface similar to "time" and "/usr/bin/time", e.g. measure-net-data <prog_to_run> <prog_args> Received (b): XYZ Sent (b): ABC I know that there are many tools for bandwidth/network monitoring, but as far I can tell all of them are performing the measurements it real-time, which is inappropriate not only because of overhead but also because of the inconvenience - I would need to stop the program, capture the output of the tool and then kill it. I have seen that newer versions of Linux 2.6.20+ provide /proc/<pid>/io/ which contain the information I'm looking for; however, everything under /proc/<pid> when the process terminates, so I'm again back to the same problem as with any network monitoring tool.

    Read the article

  • Boost Thread Hanging on _endthreadex

    - by FranticPedantic
    I think I am making a simple mistake, but since I noticed there are many boost experts here, I thought I would ask for help. I am trying to use boost threads(1_40) on windows xp. The main program loads a dll, starts the thread like so (note this is not in a class, the static does not mean static to a class but private to the file). static boost::thread network_thread; network_start() { // do network stuff until quit is signaled } DllClass::InitInstance() { network_thread = boost::thread(boost::bind<void>(network_start)); } DllClass::ExitInstance() { //signal quit (which works) //the following code is slightly verbose because I'm trying to figure out what's wrong try { if (network_thread.joinable() ) { network_thread.join(); } else { TRACE("Too late!"); } } catch (boost::thread_interrupted&) { TRACE("NET INTERRUPTED"); } } The problem is that the main thread is hanging on the join, and the network thread is hanging at the end of _endthreadex. What am I misunderstanding?

    Read the article

  • installer hanging during .net 4.5 framework install

    - by Niall Collins
    I am having trouble installing Visual studio 2012 Premium Edition. I kick off the installer for it but it hangs when installing .net 4.5 framework. I have left it for hours but there is no progression in the progress bar. I have downloaded the .net 4.5 framework separately and tried to install that from msi but that also hangs similarly. The only way to kill it is by killing the process. Any ideas how I could resolve this issue, or what I need to do to trouble shoot it further? Any tips?

    Read the article

  • pxelinux hanging when booting client machine

    - by Blasphemophagher
    I'm kind of new to all of this, so please forgive any vagueness/misunderstandings on my part. I'm using pxelinux and VMs to create CentOS 6.0 machines that have the same install every time. I have a new VM set to boot from network, but in the process of booting up it gets stuck at "Loading 10.1.1.20:/pxelinux.0" (10.1.1.20 is the address of the server it's getting info from). pxelinux conf: http://pastebin.com/4XfZZPY1 I'm pretty sure all my config files are correct, could it be VirtualBox related? I have both the building server and the new client set to Host-only adapter and PCNET-FAST.

    Read the article

  • The Problem Should Define the Process, Not the Tool

    - by thatjeffsmith
    All around awesome tool, but not the only gadget in your toolbox.I’m stepping down from my SQL Developer pulpit today and standing up on my philosophical soap box. I’m frequently asked to help folks transition from one set of database tools over to Oracle SQL Developer, which I’m MORE than happy to do. But, I’m not looking to simply change the way people interact with Oracle database. What I care about is your productivity. Is there a faster, more efficient way for you to connect the dots, get from A to B, or just get home to your kids or to the pub for happy hour? If you have defined a business process around a specific tool, what happens when that tool ‘goes away?’ Does the business stop? No, you feel immediate pain until you are able to re-implement the process using another mechanism. Where I get confused, or even frustrated, is when someone asks me to redesign our tool to match their problem. Tools are just tools. Saying you ‘can’t load your data anymore because XYZ’ isn’t valid when you could easily do that same task via SQL*Loader, Create Table As Selects, or 9 other different mechanisms. Sometimes changes brings opportunity for improvement in the process. Don’t be afraid to step back and re-evaluate a problem with a fresh set of eyes. Just trying to replicate your process in another tool exactly as it was done in the ‘old tool’ doesn’t always make sense. Quick sidebar: scheduling a Windows program to kick off thousands if not millions of table inserts from Excel versus using a ‘proper’ server process using SQL*Loader and or external tables means sacrificing scalability and reliability for convenience. Don’t let old habits blind you to new solutions and possibilities. Of couse I’m not going to sit here and say that our tools aren’t deficient in some areas or can’t be improved upon. But I bet if we work together we can find something that’s not only better for the business, but is also better for you. What do you ‘miss’ since you’ve started using SQL Developer as your primary Oracle database tools? I’d love to start a thread here and share ideas on how we can better serve you and your organizations needs. The end solution might not look exactly what you have in mind starting out, but I had no idea I’d be a Product Manager when I started college either What can you no longer ‘do’ since you picked up SQL Developer? What hurts more than it should? What keeps you from being great versus just good?

    Read the article

  • JMS Step 5 - How to Create an 11g BPEL Process Which Reads a Message Based on an XML Schema from a JMS Queue

    - by John-Brown.Evans
    JMS Step 5 - How to Create an 11g BPEL Process Which Reads a Message Based on an XML Schema from a JMS Queue .jblist{list-style-type:disc;margin:0;padding:0;padding-left:0pt;margin-left:36pt} ol{margin:0;padding:0} .c12_5{vertical-align:top;width:468pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c8_5{vertical-align:top;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 0pt 5pt} .c10_5{vertical-align:top;width:207pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c14_5{vertical-align:top;border-style:solid;border-color:#000000;border-width:1pt;padding:0pt 5pt 0pt 5pt} .c21_5{background-color:#ffffff} .c18_5{color:#1155cc;text-decoration:underline} .c16_5{color:#666666;font-size:12pt} .c5_5{background-color:#f3f3f3;font-weight:bold} .c19_5{color:inherit;text-decoration:inherit} .c3_5{height:11pt;text-align:center} .c11_5{font-weight:bold} .c20_5{background-color:#00ff00} .c6_5{font-style:italic} .c4_5{height:11pt} .c17_5{background-color:#ffff00} .c0_5{direction:ltr} .c7_5{font-family:"Courier New"} .c2_5{border-collapse:collapse} .c1_5{line-height:1.0} .c13_5{background-color:#f3f3f3} .c15_5{height:0pt} .c9_5{text-align:center} .title{padding-top:24pt;line-height:1.15;text-align:left;color:#000000;font-size:36pt;font-family:"Arial";font-weight:bold;padding-bottom:6pt} .subtitle{padding-top:18pt;line-height:1.15;text-align:left;color:#666666;font-style:italic;font-size:24pt;font-family:"Georgia";padding-bottom:4pt} li{color:#000000;font-size:10pt;font-family:"Arial"} p{color:#000000;font-size:10pt;margin:0;font-family:"Arial"} h1{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:24pt;font-family:"Arial";font-weight:normal} h2{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:normal} h3{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:14pt;font-family:"Arial";font-weight:normal} h4{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:12pt;font-family:"Arial";font-weight:normal} h5{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:11pt;font-family:"Arial";font-weight:normal} h6{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:10pt;font-family:"Arial";font-weight:normal} Welcome to another post in the series of blogs which demonstrates how to use JMS queues in a SOA context. The previous posts were: JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g JMS Step 2 - Using the QueueSend.java Sample Program to Send a Message to a JMS Queue JMS Step 3 - Using the QueueReceive.java Sample Program to Read a Message from a JMS Queue JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue Today we will create a BPEL process which will read (dequeue) the message from the JMS queue, which we enqueued in the last example. The JMS adapter will dequeue the full XML payload from the queue. 1. Recap and Prerequisites In the previous examples, we created a JMS Queue, a Connection Factory and a Connection Pool in the WebLogic Server Console. Then we designed and deployed a BPEL composite, which took a simple XML payload and enqueued it to the JMS queue. In this example, we will read that same message from the queue, using a JMS adapter and a BPEL process. As many of the configuration steps required to read from that queue were done in the previous samples, this one will concentrate on the new steps. A summary of the required objects is listed below. To find out how to create them please see the previous samples. They also include instructions on how to verify the objects are set up correctly. WebLogic Server Objects Object Name Type JNDI Name TestConnectionFactory Connection Factory jms/TestConnectionFactory TestJMSQueue JMS Queue jms/TestJMSQueue eis/wls/TestQueue Connection Pool eis/wls/TestQueue Schema XSD File The following XSD file is used for the message format. It was created in the previous example and will be copied to the new process. stringPayload.xsd <?xml version="1.0" encoding="windows-1252" ?> <xsd:schema xmlns:xsd="http://www.w3.org/2001/XMLSchema"                 xmlns="http://www.example.org"                 targetNamespace="http://www.example.org"                 elementFormDefault="qualified">   <xsd:element name="exampleElement" type="xsd:string">   </xsd:element> </xsd:schema> JMS Message After executing the previous samples, the following XML message should be in the JMS queue located at jms/TestJMSQueue: <?xml version="1.0" encoding="UTF-8" ?><exampleElement xmlns="http://www.example.org">Test Message</exampleElement> JDeveloper Connection You will need a valid Application Server Connection in JDeveloper pointing to the SOA server which the process will be deployed to. 2. Create a BPEL Composite with a JMS Adapter Partner Link In the previous example, we created a composite in JDeveloper called JmsAdapterWriteSchema. In this one, we will create a new composite called JmsAdapterReadSchema. There are probably many ways of incorporating a JMS adapter into a SOA composite for incoming messages. One way is design the process in such a way that the adapter polls for new messages and when it dequeues one, initiates a SOA or BPEL instance. This is possibly the most common use case. Other use cases include mid-flow adapters, which are activated from within the BPEL process. In this example we will use a polling adapter, because it is the most simple to set up and demonstrate. But it has one disadvantage as a demonstrative model. When a polling adapter is active, it will dequeue all messages as soon as they reach the queue. This makes it difficult to monitor messages we are writing to the queue, because they will disappear from the queue as soon as they have been enqueued. To work around this, we will shut down the composite after deploying it and restart it as required. (Another solution for this would be to pause the consumption for the queue and resume consumption again if needed. This can be done in the WLS console JMS-Modules -> queue -> Control -> Consumption -> Pause/Resume.) We will model the composite as a one-way incoming process. Usually, a BPEL process will do something useful with the message after receiving it, such as passing it to a database or file adapter, a human workflow or external web service. But we only want to demonstrate how to dequeue a JMS message using BPEL and a JMS adapter, so we won’t complicate the design with further activities. However, we do want to be able to verify that we have read the message correctly, so the BPEL process will include a small piece of embedded java code, which will print the message to standard output, so we can view it in the SOA server’s log file. Alternatively, you can view the instance in the Enterprise Manager and verify the message. The following steps are all executed in JDeveloper. Create the project in the same JDeveloper application used for the previous examples or create a new one. Create a SOA Project Create a new project and choose SOA Tier > SOA Project as its type. Name it JmsAdapterReadSchema. When prompted for the composite type, choose Empty Composite. Create a JMS Adapter Partner Link In the composite editor, drag a JMS adapter over from the Component Palette to the left-hand swim lane, under Exposed Services. This will start the JMS Adapter Configuration Wizard. Use the following entries: Service Name: JmsAdapterRead Oracle Enterprise Messaging Service (OEMS): Oracle WebLogic JMS AppServer Connection: Use an application server connection pointing to the WebLogic server on which the JMS queue and connection factory mentioned under Prerequisites above are located. Adapter Interface > Interface: Define from operation and schema (specified later) Operation Type: Consume Message Operation Name: Consume_message Consume Operation Parameters Destination Name: Press the Browse button, select Destination Type: Queues, then press Search. Wait for the list to populate, then select the entry for TestJMSQueue , which is the queue created in a previous example. JNDI Name: The JNDI name to use for the JMS connection. As in the previous example, this is probably the most common source of error. This is the JNDI name of the JMS adapter’s connection pool created in the WebLogic Server and which points to the connection factory. JDeveloper does not verify the value entered here. If you enter a wrong value, the JMS adapter won’t find the queue and you will get an error message at runtime, which is very difficult to trace. In our example, this is the value eis/wls/TestQueue . (See the earlier step on how to create a JMS Adapter Connection Pool in WebLogic Server for details.) Messages/Message SchemaURL: We will use the XSD file created during the previous example, in the JmsAdapterWriteSchema project to define the format for the incoming message payload and, at the same time, demonstrate how to import an existing XSD file into a JDeveloper project. Press the magnifying glass icon to search for schema files. In the Type Chooser, press the Import Schema File button. Select the magnifying glass next to URL to search for schema files. Navigate to the location of the JmsAdapterWriteSchema project > xsd and select the stringPayload.xsd file. Check the “Copy to Project” checkbox, press OK and confirm the following Localize Files popup. Now that the XSD file has been copied to the local project, it can be selected from the project’s schema files. Expand Project Schema Files > stringPayload.xsd and select exampleElement: string . Press Next and Finish, which will complete the JMS Adapter configuration.Save the project. Create a BPEL Component Drag a BPEL Process from the Component Palette (Service Components) to the Components section of the composite designer. Name it JmsAdapterReadSchema and select Template: Define Service Later and press OK. Wire the JMS Adapter to the BPEL Component Now wire the JMS adapter to the BPEL process, by dragging the arrow from the adapter to the BPEL process. A Transaction Properties popup will be displayed. Set the delivery mode to async.persist. This completes the steps at the composite level. 3 . Complete the BPEL Process Design Invoke the BPEL Flow via the JMS Adapter Open the BPEL component by double-clicking it in the design view of the composite.xml, or open it from the project navigator by selecting the JmsAdapterReadSchema.bpel file. This will display the BPEL process in the design view. You should see the JmsAdapterRead partner link in the left-hand swim lane. Drag a Receive activity onto the BPEL flow diagram, then drag a wire (left-hand yellow arrow) from it to the JMS adapter. This will open the Receive activity editor. Auto-generate the variable by pressing the green “+” button and check the “Create Instance” checkbox. This will result in a BPEL instance being created when a new JMS message is received. At this point it would actually be OK to compile and deploy the composite and it would pick up any messages from the JMS queue. In fact, you can do that to test it, if you like. But it is very rudimentary and would not be doing anything useful with the message. Also, you could only verify the actual message payload by looking at the instance’s flow in the Enterprise Manager. There are various other possibilities; we could pass the message to another web service, write it to a file using a file adapter or to a database via a database adapter etc. But these will all introduce unnecessary complications to our sample. So, to keep it simple, we will add a small piece of Java code to the BPEL process which will write the payload to standard output. This will be written to the server’s log file, which will be easy to monitor. Add a Java Embedding Activity First get the full name of the process’s input variable, as this will be needed for the Java code. Go to the Structure pane and expand Variables > Process > Variables. Then expand the input variable, for example, "Receive1_Consume_Message_InputVariable > body > ns2:exampleElement”, and note variable’s name and path, if they are different from this one. Drag a Java Embedding activity from the Component Palette (Oracle Extensions) to the BPEL flow, after the Receive activity, then open it to edit. Delete the example code and replace it with the following, replacing the variable parts with those in your sample, if necessary.: System.out.println("JmsAdapterReadSchema process picked up a message"); oracle.xml.parser.v2.XMLElement inputPayload =    (oracle.xml.parser.v2.XMLElement)getVariableData(                           "Receive1_Consume_Message_InputVariable",                           "body",                           "/ns2:exampleElement");   String inputString = inputPayload.getFirstChild().getNodeValue(); System.out.println("Input String is " + inputPayload.getFirstChild().getNodeValue()); Tip. If you are not sure of the exact syntax of the input variable, create an Assign activity in the BPEL process and copy the variable to another, temporary one. Then check the syntax created by the BPEL designer. This completes the BPEL process design in JDeveloper. Save, compile and deploy the process to the SOA server. 3. Test the Composite Shut Down the JmsAdapterReadSchema Composite After deploying the JmsAdapterReadSchema composite to the SOA server it is automatically activated. If there are already any messages in the queue, the adapter will begin polling them. To ease the testing process, we will deactivate the process first Log in to the Enterprise Manager (Fusion Middleware Control) and navigate to SOA > soa-infra (soa_server1) > default (or wherever you deployed your composite to) and click on JmsAdapterReadSchema [1.0] . Press the Shut Down button to disable the composite and confirm the following popup. Monitor Messages in the JMS Queue In a separate browser window, log in to the WebLogic Server Console and navigate to Services > Messaging > JMS Modules > TestJMSModule > TestJMSQueue > Monitoring. This is the location of the JMS queue we created in an earlier sample (see the prerequisites section of this sample). Check whether there are any messages already in the queue. If so, you can dequeue them using the QueueReceive Java program created in an earlier sample. This will ensure that the queue is empty and doesn’t contain any messages in the wrong format, which would cause the JmsAdapterReadSchema to fail. Send a Test Message In the Enterprise Manager, navigate to the JmsAdapterWriteSchema created earlier, press Test and send a test message, for example “Message from JmsAdapterWriteSchema”. Confirm that the message was written correctly to the queue by verifying it via the queue monitor in the WLS Console. Monitor the SOA Server’s Output A program deployed on the SOA server will write its standard output to the terminal window in which the server was started, unless this has been redirected to somewhere else, for example to a file. If it has not been redirected, go to the terminal session in which the server was started, otherwise open and monitor the file to which it was redirected. Re-Enable the JmsAdapterReadSchema Composite In the Enterprise Manager, navigate to the JmsAdapterReadSchema composite again and press Start Up to re-enable it. This should cause the JMS adapter to dequeue the test message and the following output should be written to the server’s standard output: JmsAdapterReadSchema process picked up a message. Input String is Message from JmsAdapterWriteSchema Note that you can also monitor the payload received by the process, by navigating to the the JmsAdapterReadSchema’s Instances tab in the Enterprise Manager. Then select the latest instance and view the flow of the BPEL component. The Receive activity will contain and display the dequeued message too. 4 . Troubleshooting This sample demonstrates how to dequeue an XML JMS message using a BPEL process and no additional functionality. For example, it doesn’t contain any error handling. Therefore, any errors in the payload will result in exceptions being written to the log file or standard output. If you get any errors related to the payload, such as Message handle error ... ORABPEL-09500 ... XPath expression failed to execute. An error occurs while processing the XPath expression; the expression is /ns2:exampleElement. ... etc. check that the variable used in the Java embedding part of the process was entered correctly. Possibly follow the tip mentioned in previous section. If this doesn’t help, you can delete the Java embedding part and simply verify the message via the flow diagram in the Enterprise Manager. Or use a different method, such as writing it to a file via a file adapter. This concludes this example. In the next post, we will begin with an AQ JMS example, which uses JMS to write to an Advanced Queue stored in the database. Best regards John-Brown Evans Oracle Technology Proactive Support Delivery

    Read the article

  • SSH server not working (respawns until stopped)

    - by Khaled
    I have a running Ubuntu Server 10.04.1. When I tried to login to the server via ssh, I could not. Instead, I got connection refused error. I tried to ping the machine and I got reply! So, the clear reason is that SSH daemon is stopped. After reboot, I was able to login to my server via ssh. After some time, I looked at my logs /var/log/syslog and found the following records: Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2465) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2469) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2473) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2477) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2481) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2485) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2489) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2493) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2497) terminated with status 255 Jan 16 10:57:09 myserver init: ssh main process ended, respawning Jan 16 10:57:09 myserver init: ssh main process (2501) terminated with status 255 Jan 16 10:57:09 myserver init: ssh respawning too fast, stopped I searched for a similar problem/solution. Some people said that this is caused by the SSH daemon trying to start before networking and they suggest to change ListenAddress in /etc/ssh/sshd_config to be 0.0.0.0. I think this is not the cause in my case, because my problem occurs after system is up and running. Any idea what is causing this? This is Ubuntu Server and it should be running and accessed remotely using SSH.

    Read the article

  • Role of "Refactoring" in good programming pratices?

    - by Niranjan Kala
    I have learned in Agile Development that: Refactoring is the process of clarifying and simplifying the design of existing code, without changing its behavior. I have heard about some GUI refactoring tools like resharper and DevExpress Refactor Pro! Here is my Questions: Question 1: how does it takes place in the Software development process and How far it effects the system? Question 2: Is Refactoring using these tools really fast the process of development/ maintenance?

    Read the article

  • Restarting shell script with &disown using Monit

    - by Solas Admin
    I have a shell script that runs a C++ backend mail system (PluginHandler). I need to monitor this process in Monit and restart it if it fails. The script: export LD_LIBRARY_PATH=/usr/local/lib/:/CONFIDENTAL/CONFIDENTAL/Common/ cd PluginHandler/ ./PluginHandler This script does not have a PID file and we run this script by executing ./rundaemon.sh &disown ./pluginhandler starts the process and starts logging into /etc/output/output.log I stop the process by identifying the process ID with [ps -f | grep PluginHandler] and then killing the process. I can check the process in Monit just fine, but I think Monit is starting the process if it is not running but it can't do &disown so the process ends as soon as it starts. This is the code in the monitrc file for checking this process: check process Backend matching "PluginHandler" if not exist then alert start "PATH/TO/SCRIPT/rundaemon.sh &disown" alert [email protected] only on {timeout} with mail-format {subject: "[BLAH"} I tried to stop the script from terminating by modifying the script like the following but this does not work either. export LD_LIBRARY_PATH=/usr/local/lib/:/home/CONFIDENTAL/production/CONFIDENTAL/Common/ cd PluginHandler/ (nohup ./PluginHandler &) return Any help to write a proper Monit rules to resolve this issue would be greatly appreciated :)

    Read the article

  • How Mature is Your Database Change Management Process?

    - by Ben Rees
    .dbd-banner p{ font-size:0.75em; padding:0 0 10px; margin:0 } .dbd-banner p span{ color:#675C6D; } .dbd-banner p:last-child{ padding:0; } @media ALL and (max-width:640px){ .dbd-banner{ background:#f0f0f0; padding:5px; color:#333; margin-top: 5px; } } -- Database Delivery Patterns & Practices Further Reading Organization and team processes How do you get your database schema changes live, on to your production system? As your team of developers and DBAs are working on the changes to the database to support your business-critical applications, how do these updates wend their way through from dev environments, possibly to QA, hopefully through pre-production and eventually to production in a controlled, reliable and repeatable way? In this article, I describe a model we use to try and understand the different stages that customers go through as their database change management processes mature, from the very basic and manual, through to advanced continuous delivery practices. I also provide a simple chart that will help you determine “How mature is our database change management process?” This process of managing changes to the database – which all of us who have worked in application/database development have had to deal with in one form or another – is sometimes known as Database Change Management (even if we’ve never used the term ourselves). And it’s a difficult process, often painfully so. Some developers take the approach of “I’ve no idea how my changes get live – I just write the stored procedures and add columns to the tables. It’s someone else’s problem to get this stuff live. I think we’ve got a DBA somewhere who deals with it – I don’t know, I’ve never met him/her”. I know I used to work that way. I worked that way because I assumed that making the updates to production was a trivial task – how hard can it be? Pause the application for half an hour in the middle of the night, copy over the changes to the app and the database, and switch it back on again? Voila! But somehow it never seemed that easy. And it certainly was never that easy for database changes. Why? Because you can’t just overwrite the old database with the new version. Databases have a state – more specifically 4Tb of critical data built up over the last 12 years of running your business, and if your quick hotfix happened to accidentally delete that 4Tb of data, then you’re “Looking for a new role” pretty quickly after the failed release. There are a lot of other reasons why a managed database change management process is important for organisations, besides job security, not least: Frequency of releases. Many business managers are feeling the pressure to get functionality out to their users sooner, quicker and more reliably. The new book (which I highly recommend) Lean Enterprise by Jez Humble, Barry O’Reilly and Joanne Molesky provides a great discussion on how many enterprises are having to move towards a leaner, more frequent release cycle to maintain their competitive advantage. It’s no longer acceptable to release once per year, leaving your customers waiting all year for changes they desperately need (and expect) Auditing and compliance. SOX, HIPAA and other compliance frameworks have demanded that companies implement proper processes for managing changes to their databases, whether managing schema changes, making sure that the data itself is being looked after correctly or other mechanisms that provide an audit trail of changes. We’ve found, at Red Gate that we have a very wide range of customers using every possible form of database change management imaginable. Everything from “Nothing – I just fix the schema on production from my laptop when things go wrong, and write it down in my notebook” to “A full Continuous Delivery process – any change made by a dev gets checked in and recorded, fully tested (including performance tests) before a (tested) release is made available to our Release Management system, ready for live deployment!”. And everything in between of course. Because of the vast number of customers using so many different approaches we found ourselves struggling to keep on top of what everyone was doing – struggling to identify patterns in customers’ behavior. This is useful for us, because we want to try and fit the products we have to different needs – different products are relevant to different customers and we waste everyone’s time (most notably, our customers’) if we’re suggesting products that aren’t appropriate for them. If someone visited a sports store, looking to embark on a new fitness program, and the store assistant suggested the latest $10,000 multi-gym, complete with multiple weights mechanisms, dumb-bells, pull-up bars and so on, then he’s likely to lose that customer. All he needed was a pair of running shoes! To solve this issue – in an attempt to simplify how we understand our customers and our offerings – we built a model. This is a an attempt at trying to classify our customers in to some sort of model or “Customer Maturity Framework” as we rather grandly term it, which somehow simplifies our understanding of what our customers are doing. The great statistician, George Box (amongst other things, the “Box” in the Box-Jenkins time series model) gave us the famous quote: “Essentially all models are wrong, but some are useful” We’ve taken this quote to heart – we know it’s a gross over-simplification of the real world of how users work with complex legacy and new database developments. Almost nobody precisely fits in to one of our categories. But we hope it’s useful and interesting. There are actually a number of similar models that exist for more general application delivery. We’ve found these from ThoughtWorks/Forrester, from InfoQ and others, and initially we tried just taking these models and replacing the word “application” for “database”. However, we hit a problem. From talking to our customers we know that users are far less further down the road of mature database change management than they are for application development. As a simple example, no application developer, who wants to keep his/her job would develop an application for an organisation without source controlling that code. Sure, he/she might not be using an advanced Gitflow branching methodology but they’ll certainly be making sure their code gets managed in a repo somewhere with all the benefits of history, auditing and so on. But this certainly isn’t the case (yet) for the database – a very large segment of the people we speak to have no source control set up for their databases whatsoever, even at the most basic level (for example, keeping change scripts in a source control system somewhere). By the way, if this is you, Red Gate has a great whitepaper here, on the barriers people face getting a source control process implemented at their organisations. This difference in maturity is the same as you move in to areas such as continuous integration (common amongst app developers, relatively rare for database developers) and automated release management (growing amongst app developers, very rare for the database). So, when we created the model we started from scratch and biased the levels of maturity towards what we actually see amongst our customers. But, what are these stages? And what level are you? The table below describes our definitions for four levels of maturity – Baseline, Beginner, Intermediate and Advanced. As I say, this is a model – you won’t fit any of these categories perfectly, but hopefully one will ring true more than others. We’ve also created a PDF with a flow chart to help you find which of these groups most closely matches your team:  Download the Database Delivery Maturity Framework PDF here   Level D1 – Baseline Work directly on live databases Sometimes work directly in production Generate manual scripts for releases. Sometimes use a product like SQL Compare or similar to do this Any tests that we might have are run manually Level D2 – Beginner Have some ad-hoc DB version control such as manually adding upgrade scripts to a version control system Attempt is made to keep production in sync with development environments There is some documentation and planning of manual deployments Some basic automated DB testing in process Level D3 – Intermediate The database is fully version-controlled with a product like Red Gate SQL Source Control or SSDT Database environments are managed Production environment schema is reproducible from the source control system There are some automated tests Have looked at using migration scripts for difficult database refactoring cases Level D4 – Advanced Using continuous integration for database changes Build, testing and deployment of DB changes carried out through a proper database release process Fully automated tests Production system is monitored for fast feedback to developers   Does this model reflect your team at all? Where are you on this journey? We’d be very interested in knowing how you get on. We’re doing a lot of work at the moment, at Red Gate, trying to help people progress through these stages. For example, if you’re currently not source controlling your database, then this is a natural next step. If you are already source controlling your database, what about the next stage – continuous integration and automated release management? To help understand these issues, there’s a summary of the Red Gate Database Delivery learning program on our site, alongside a Patterns and Practices library here on Simple-Talk and a Training Academy section on our documentation site to help you get up and running with the tools you need to progress. All feedback is welcome and it would be great to hear where you find yourself on this journey! This article is part of our database delivery patterns & practices series on Simple Talk. Find more articles for version control, automated testing, continuous integration & deployment.

    Read the article

  • How do I ensure a process is running, even if it kills itself? (it needs to be restarted then)

    - by le_me
    I'm using linux. I want a process (an irc bot) to run every time I start the computer. But I've got a problem: The network is bad and it disconnects often, so I need to manually restart the bot a few times a day. How do I automate that? Additional information: The bot creates a pid file, called bot.pid The bot reconnects itself, but only a few times. The network is too bad, so the bot kills itself sometimes because it gets no response. What I do currently (aka my approach ;) ) I have a cron job executing startbot.rb every 5 minutes. (The script itself is in the same directory as the bot) The script: #!/usr/bin/ruby require 'fileutils' if File.exists?(File.expand_path('tmp/bot.pid')) @pid = File.read(File.expand_path('tmp/bot.pid')).chomp!.to_i begin raise "ouch" if Process.kill(0, @pid) != 1 rescue puts "Removing abandoned pid file" FileUtils.rm(File.expand_path('tmp/bot.pid')) puts "Starting the bot!" Kernel.exec(File.expand_path('./bot.rb')) else puts "Bot up and running!" end else puts "Starting the bot!" Kernel.exec(File.expand_path('./bot.rb')) end What this does: It checks if the pid file exists, if that's true it checks if kill -s 0 BOT_PID == 1 (if the bot's running) and starts the bot if one of the two checks fail/are not true. My approach seems to be quite dirty so how do I do it better?

    Read the article

  • Windows XP hanging on login screen

    - by Nathan W
    I have been given two Eee PC 100HA to manage for some people, they are both running the same hardware and XP home but one is having some strange problems with logging on. The main problem is that it hangs at the login screen for ages and sometimes never gets to the desktop. The strange thing is it only seems to do it after the computer has been cold started, but it won't do it if the computer has been restarted. I have made two logs of the start up with process monitor but every time the logger is attached the computer will log in fine. I have also set the computer to blue screen and create a crash dump when you press ctrl scroll twice but when I do it at the hung login it just sits at a black screen and I don't get a crash dump, I have turned off the auto system restart on failure option also. I can usually fix most computer start up and shutdown problems but this one has got me stuffed. Has anyone had the same problems before, or can recommend something that I can try? Cheers.

    Read the article

  • Explorer constantly hanging

    - by user978122
    So I'm running Windows 7 Ultimate (x64) an AMD 8150 on an Asus Crosshair V motherboard with all the latest and greatest patches, and I am experiencing frequent Explorer freezes. I've included the information I've grepped from the Event Viewer below: The program Explorer.EXE version 6.1.7601.17567 stopped interacting with Windows and was closed. To see if more information about the problem is available, check the problem history in the Action Center control panel. Process ID: 13a4 Start Time: 01cdb2968999c6fd Termination Time: 0 Application Path: C:\Windows\Explorer.EXE Report Id: c000ba44-1e8b-11e2-9ae7-000272ddf2b0 - System - Provider [ Name] Application Hang - EventID 1002 [ Qualifiers] 0 Level 2 Task 101 Keywords 0x80000000000000 - TimeCreated [ SystemTime] 2012-10-25T10:08:44.000000000Z EventRecordID 14626 Channel Application Computer RyanMain-PC Security - EventData Explorer.EXE 6.1.7601.17567 13a4 01cdb2968999c6fd 0 C:\Windows\Explorer.EXE c000ba44-1e8b-11e2-9ae7-000272ddf2b0 430072006F00730073002D0074006800720065006100640000000000 -------------------------------------------------------------------------------- Binary data: In Words 0000: 00720043 0073006F 002D0073 00680074 0008: 00650072 00640061 00000000 In Bytes 0000: 43 00 72 00 6F 00 73 00 C.r.o.s. 0008: 73 00 2D 00 74 00 68 00 s.-.t.h. 0010: 72 00 65 00 61 00 64 00 r.e.a.d. 0018: 00 00 00 00 .... Any idea what "Cross-thread" here means?

    Read the article

  • Mulitple processes aware of each other

    - by Abhan
    Hope you can help me with this, I've searched a lot and I got really confused of what to do here. I'm building a program in C and I need to run it multiple time as I need. So it's going to be like below, process 1 handle all rows on DB table test where process_flag=1 process 2 handle all rows on DB table test where process_flag=2 process 3 handle all rows on DB table test where process_flag=3 and so on How can I make the processes aware of each other, so if process 3 goes down then processes 2 & 3 start working on process_flag=3?

    Read the article

  • How do I find and kill a php loop (process)?

    - by Hoytman
    I have a php script that I have been developing which calls an external api within a loop. It is being tested on a VPS which is running LAMP on Debian. I noticed this morning that the api was not responding to my script. When I called the provider, they told me that my server had been calling the api 1000's of times per hour for the past 10 hours. I am assuming that a php script (which I have been working on the day before and testing on my VPS) entered into an infinite loop during one of the executions, and never came out (I have been testing it from the command prompt, and not over the web.) I have attempted to stop and start Apache, but the api support staff says that the calls are still coming in from my server address. How can I find and stop the process? Also, is there a possibility that the Apache stop/start solved the problem, but the api is still trying to sort through past calls? Please forgive me for not using my local test environment correctly. Edit: I do not know the process name, I need to discover the name (or pid) based on behavior.

    Read the article

  • How to detect that a process is started using C# code[windows service]

    - by infant programmer
    I am trying to design a windows-service which monitors a process namely "Gtalk", if the process is started then, the browser Internet-explorer (process iexplore) should be closed. This should happen only when the process "Gtalk" is started, [not when running] The code I have written and implemented, doesn't allow to open IExplore when Gtalk is running. That is certainly what not I am trying for. The process Gtalk should close browser only at its start-up, After the process is started, it should allow to open IExplore. Is it possible with Windows service or is it must be the part of Gtalk process itself? This is my code: while (true) { if (Process.GetProcessesByName("Gtalk").Length > 0) { foreach (Process prc in Process.GetProcessesByName("IExplore")) { prc.Kill(); } } }

    Read the article

  • Running control.exe as process does not WaitForExit()

    - by Lisa Alliss
    I am running control.exe as a process. (Windows 7 OS, .NET 3.5, C#). It does not stop at WaitForExit() as expected. It immediately "exits" the process even though the control.exe window is still open. I have tried the process.Exited event also and that is triggered before the application exits as well. Here is my code: Process process = new Process(); process.StartInfo.FileName = @"c:\windows\system32\control.exe"; process.StartInfo.Arguments = @"userpasswords"; process.Start(); process.WaitForExit();

    Read the article

  • Process.Start() and ShellExecute() fails with URLs on Windows 8

    - by Rick Strahl
    Since I installed Windows 8 I've noticed that a number of my applications appear to have problems opening URLs. That is when I click on a link inside of a Windows application, either nothing happens or there's an error that occurs. It's happening both to my own applications and a host of Windows applications I'm running. At first I thought this was an issue with my default browser (Chrome) but after switching the default browser to a few others and experimenting a bit I noticed that the errors occur - oddly enough - only when I run an application as an Administrator. I also tried switching to FireFox and Opera as my default browser and saw exactly the same behavior. The scenario for this is a bit bizarre: Running on Windows 8 Call Process.Start() (or ShellExecute() in Win32 API) with a URL or an HTML file Run 'As Administrator' (works fine under non-elevated user account!) or with UAC off A browser other than Internet Explorer is set as your Default Web Browser Talk about a weird scenario: Something that doesn't work when you run as an Administrator which is supposed to have rights to everything on the system! Instead running under an Admin account - either elevated with a User Account Control prompt or even when running as a full Administrator fails. It appears that this problem does not occur for everyone, but when I looked for a solution to this, I saw quite a few posts in relation to this with no clear resolutions. I have three Windows 8 machines running here in the office and all three of them showed this behavior. Lest you think this is just a programmer's problem - this can affect any software running on your system that needs to run under administrative rights. Try it out Now, in order for this next example to fail, any browser but Internet Explorer has to be your default browser and even then it may not fail depending on how you installed your browser. To see if this is a problem create a small Console application and call Process.Start() with a URL in it:namespace Win8ShellBugConsole { class Program { static void Main(string[] args) { Console.WriteLine("Launching Url..."); Process.Start("http://microsoft.com"); Console.Write("Press any key to continue..."); Console.ReadKey(); Console.WriteLine("\r\n\r\nLaunching image..."); Process.Start(Path.GetFullPath(@"..\..\sailbig.jpg")); Console.Write("Press any key to continue..."); Console.ReadKey(); } } } Compile this code. Then execute the code from Explorer (not from Visual Studio because that may change the permissions). If you simply run the EXE and you're not running as an administrator, you'll see the Web page pop up in the browser as well as the image loading. Now run the same thing with Run As Administrator: Now when you run it you get a nice error when Process.Start() is fired: The same happens if you are running with User Account Control off altogether - ie. you are running as a full admin account. Now if you comment out the URL in the code above and just fire the image display - that works just fine in any user mode. As does opening any other local file type or even starting a new EXE locally (ie. Process.Start("c:\windows\notepad.exe"). All that works, EXCEPT for URLs. The code above uses Process.Start() in .NET but the same happens in Win32 Applications that use the ShellExecute API. In some of my older Fox apps ShellExecute returns an error code of 31 - which is No Shell Association found. What's the Deal? It turns out the problem has to do with the way browsers are registering themselves on Windows. Internet Explorer - being a built-in application in Windows 8 - apparently does this correctly, but other browsers possibly don't or at least didn't at the time I installed them. So even Chrome, which continually updates itself, has a recent version that apparently has this registration issue fixed, I was unable to simply set IE as my default browser then use Chrome to 'Set as Default Browser'. It still didn't work. Neither did using the Set Program Associations dialog which lets you assign what extensions are mapped to by a given application. Each application provides a set of extension/moniker mappings that it supports and this dialog lets you associate them on a system wide basis. This also did not work for Chrome or any of the other browsers at first. However, after repeated retries here eventually I did manage to get FireFox to work, but not any of the others. What Works? Reinstall the Browser In the end I decided on the hard core pull the plug solution: Totally uninstall and re-install Chrome in this case. And lo and behold, after reinstall everything was working fine. Now even removing the association for Chrome, switching to IE as the default browser and then back to Chrome works. But, even though the version of Chrome I was running before uninstalling and reinstalling is the same as I'm running now after the reinstall now it works. Of course I had to find out the hard way, before Richard commented with a note regarding what the issue is with Chrome at least: http://code.google.com/p/chromium/issues/detail?id=156400 As expected the issue is a registration issue - with keys not being registered at the machine level. Reading this I'm still not sure why this should be a problem - an elevated account still runs under the same user account (ie. I'm still rickstrahl even if I Run As Administrator), so why shouldn't an app be able to read my Current User registry hive? And also that doesn't quite explain why if I register the extensions using Run As Administrator in Chrome when using Set as Default Browser). But in the end it works… Not so fast It's now a couple of days later and still there are some oddball problems although this time they appear to be purely Chrome issues. After the reinstall Chrome seems to pop up properly with ShellExecute() calls both in regular user and Admin mode. However, it now looks like Chrome is actually running two completely separate user profiles for each. For example, when I run Visual Studio in Admin mode and go to View in browser, Chrome complains that it was installed in Admin mode and can't launch (WTF?). Then you retry a few times later and it ends up working. When launched that way some of the plug-ins installed don't show up with the effect that sometimes they're visible sometimes they're not. Also Chrome seems to loose my configuration and Google sign in between sessions now, presumably when switching user modes. Add-ins installed in admin mode don't show up in user mode and vice versa. Ah, this is lovely. Did I mention that I freaking hate UAC precisely because of this kind of bullshit. You can never tell exactly what account your app is running under, and apparently apps also have a hard time trying to put data into the right place that works for both scenarios. And as my recent post on using Windows Live accounts shows it's yet another level of abstraction ontop of the underlying system identity that can cause all sort of small side effect headaches like this. Hopefully, most of you are skirting this issue altogether - having installed more recent versions of your favorite browsers. If not, hopefully this post will take you straight to reinstallation to fix this annoying issue.© Rick Strahl, West Wind Technologies, 2005-2012Posted in Windows  .NET   Tweet !function(d,s,id){var js,fjs=d.getElementsByTagName(s)[0];if(!d.getElementById(id)){js=d.createElement(s);js.id=id;js.src="//platform.twitter.com/widgets.js";fjs.parentNode.insertBefore(js,fjs);}}(document,"script","twitter-wjs"); (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article