Search Results

Search found 11364 results on 455 pages for 'port blocking'.

Page 16/455 | < Previous Page | 12 13 14 15 16 17 18 19 20 21 22 23  | Next Page >

  • Reading from serial port with Boost Asio?

    - by trikri
    Hi! I'm going to check for incoming messages (data packages) on the serial port, using Boost Asio. Each message will start with a header that is one byte long, and will specify which type of the message has been sent. Each different type of message has an own length. The function I'm about to write should check for new incoming messages continually, and when it finds one it should read it, and then some other function should parse it. I thought that the code might look something like this: void check_for_incoming_messages() { boost::asio::streambuf response; boost::system::error_code error; std::string s1, s2; if (boost::asio::read(port, response, boost::asio::transfer_at_least(0), error)) { s1 = streambuf_to_string(response); int msg_code = s1[0]; if (msg_code < 0 || msg_code >= NUM_MESSAGES) { // Handle error, invalid message header } if (boost::asio::read(port, response, boost::asio::transfer_at_least(message_lengths[msg_code]-s1.length()), error)) { s2 = streambuf_to_string(response); // Handle the content of s1 and s2 } else if (error != boost::asio::error::eof) { throw boost::system::system_error(error); } } else if (error != boost::asio::error::eof) { throw boost::system::system_error(error); } } Is boost::asio::streambuf is the right thing to use? And how do I extract the data from it so I can parse the message? I also want to know if I need to have a separate thread which only calls this function, so that it get called more often? Isn't there a risk for loosing data in between two calls to the function otherwise, because so much data comes in that it can't be stored in the serial ports memory? I'm using Qt as a widget toolkit and I don't really know how long time it needs to process all it's events.

    Read the article

  • Android 3.1+ USB as virtual COM port

    - by ZachMc
    I have a third party usb device, that when plugged into a Windows machine, is recognized as a serial device and assigned to the COM 4 port. I can communicate with the device just like I would with a device connected via a serial port. For instance, I can write "abc" serially to the device via the USB connection. I have been searching for a way to do a similar thing in Android. If I try the Usb Host method, and use a UsbManager to open the UsbDevice, I can get one interface, with 2 endpoints. I have tried sending control messages using the method in UsbDeviceConnection, but the method returns -1 for everything (though I don't know what I should use for the parameters of that method). Is there a way to get an OutputStream that I can write to that will send bytes to the USB device? Right now I am looking at recompiling the kernel to include a virtual COM port driver and write some native code to be able to do this. Thanks! Edit: I am using the FTDI serial to USB converter circuit. Is this compatible with Android?

    Read the article

  • Correct initialization sequence for Linux serial port

    - by whitequark
    I wrote an application that must use serial ports on Linux, especially ttyUSB ones. Reading and writing operations are performed with standard select()/read() loop and write(), and there is probably nothing wrong in them, but initialization code (or absence of some part of it) damages something in the tty subsystem. Here it is: vuxboot(string filename, unsigned baud = B115200) : _debug(false) { _fd = open(filename.c_str(), O_RDWR | O_NOCTTY); if(!_fd) throw new io_error("cannot open port"); // Serial initialization was written with FTDI USB-to-serial converters // in mind. Anyway, who wants to use non-8n1 protocol? tcgetattr(_fd, &_termios); termios tio = {0}; tio.c_iflag = IGNPAR; tio.c_oflag = 0; tio.c_cflag = baud | CLOCAL | CREAD | CS8; tio.c_lflag = 0; tcflush(_fd, TCIFLUSH); tcsetattr(_fd, TCSANOW, &tio); } Another tcsetattr(_fd, TCSANOW, &_termios) sits in the destructor, but it is irrelevant. With or without this termios initialization, strange things happen in system after the application exits. Sometimes plain cat (or hd) exits immediately printing nothing or same stuff each time, sometimes it is waiting and not displaying any of the data that is surely sent onto the port; and close() (read() too, but not every time) emits a strange WARNING to dmesg referring to usb-serial.c. I checked the hardware and firmware tens of times (even on different machines) and I am sure it is working as intended; moreover, I stripped the firmware to just print same message over and over. How can I use serial port without destroying anything? Thanks.

    Read the article

  • Thread to receive the messages from serial port is not working using c#

    - by karthik
    I am using Serial port to receive the messages. The below function is running in a thread. When i debug i find that the thread is running properly. But "if (sp.IsOpen)" is always false, due to which the code is not executing inside the IF condition at all. It says the Port is closed. I will be having multiple serial ports in my system and i will not know, which port will receive the message. So i need to listen to all the ports in one Thread. How can i solve my problem here ? private void ListenerPorts() { log.Info("Listening Thread Started"); while (true) { //foreach (SerialPort sp in storeport) foreach (SerialPort sp in comPortsList) { if (sp.IsOpen) { sp.ReadTimeout = readTimeoutInMs; sp.WriteTimeout = writeTimeoutInMs; try { string msg = sp.ReadLine(); this.GetMessageRichTextBox("Message : " + msg + "\n"); sp.WriteLine(sp.PortName); if (msg.Contains("COM")) { // is AutoScan receiverPortName = sp.ReadLine(); this.updateLblStatusRichTextBox(sp.PortName + " is connected to " + msg + "\n"); } else { //standalone is uppercase ReceiverPortName = sp.ReadLine(); this.updateLblStatusRichTextBox(sp.PortName + " is connected to " + ReceiverPortName + "\n"); } } catch (Exception ex) { // no data System.Diagnostics.Debug.WriteLine(sp.PortName + " : " + ex.Message); } } } } }

    Read the article

  • .NET Serial Port: Port Configuration Dialog

    - by sheepsimulator
    I'm going to be writing a small app based on the .NET SerialPort class. Is there a generic dialog available for setting the port settings, ala baud rate, data bits, stop bit, parity bit, flow control, etc? I didn't see one in the MSDN documentation, but I would think that one exists, since that stuff doesn't change.

    Read the article

  • COM port read - Thread remains alive after timeout occurs

    - by Sna
    Hello to all. I have a dll which includes a function called ReadPort that reads data from serial COM port, written in c/c++. This function is called within an extra thread from another WINAPI function using the _beginthreadex. When COM port has data to be read, the worker thread returns the data, ends normaly, the calling thread closes the worker's thread handle and the dll works fine. However, if ReadPort is called without data pending on the COM port, when timeout occurs then WaitForSingleObject returns WAIT_TIMEOUT but the worker thread never ends. As a result, virtual memory grows at about 1 MB every time, physical memory grows some KBs and the application that calls the dll becomes unstable. I also tryied to use TerminateThread() but i got the same results. I have to admit that although i have enough developing experience, i am not familiar with c/c++. I did a lot of research before posting but unfortunately i didn't manage to solve my problem. Does anyone have a clue on how could i solve this problem? However, I really want to stick to this kind of solution. Also, i want to mention that i think i can't use any global variables to use some kind of extra events, because each dll's functions may be called many times for every COM port. I post some parts of my code below: The Worker Thread: unsigned int __stdcall ReadPort(void* readstr){ DWORD dwError; int rres;DWORD dwCommModemStatus, dwBytesTransferred; int ret; char szBuff[64] = ""; ReadParams* params = (ReadParams*)readstr; ret = SetCommMask(params->param2, EV_RXCHAR | EV_CTS | EV_DSR | EV_RLSD | EV_RING); if (ret == 0) { _endthreadex(0); return -1; } ret = WaitCommEvent(params->param2, &dwCommModemStatus, 0); if (ret == 0) { _endthreadex(0); return -2; } ret = SetCommMask(params->param2, EV_RXCHAR | EV_CTS | EV_DSR | EV_RLSD| EV_RING); if (ret == 0) { _endthreadex(0); return -3; } if (dwCommModemStatus & EV_RXCHAR||dwCommModemStatus & EV_RLSD) { rres = ReadFile(params->param2, szBuff, 64, &dwBytesTransferred,NULL); if (rres == 0) { switch (dwError = GetLastError()) { case ERROR_HANDLE_EOF: _endthreadex(0); return -4; } _endthreadex(0); return -5; } else { strcpy(params->param1,szBuff); _endthreadex(0); return 0; } } else { _endthreadex(0); return 0; } _endthreadex(0); return 0;} The Calling Thread: int WINAPI StartReadThread(HANDLE porthandle, HWND windowhandle){ HANDLE hThread; unsigned threadID; ReadParams readstr; DWORD ret, ret2; readstr.param2 = porthandle; hThread = (HANDLE)_beginthreadex( NULL, 0, ReadPort, &readstr, 0, &threadID ); ret = WaitForSingleObject(hThread, 500); if (ret == WAIT_OBJECT_0) { CloseHandle(hThread); if (readstr.param1 != NULL) // Send message to GUI return 0; } else if (ret == WAIT_TIMEOUT) { ret2 = CloseHandle(hThread); return -1; } else { ret2 = CloseHandle(hThread); if (ret2 == 0) return -2; }} Thank you in advance, Sna.

    Read the article

  • Blocking path scanning

    - by clinisbut
    I'm seeing in my access log a number of request very suspicious: /i /im /imaa /imag /image /images /images/d /images/di /images/dis They part from a known resource (in the above example /images/disrupt.jpg). All comming from same IP. Requests varies from 1/sec to 10/sec, seems somewhat random. It's obviously they are trying to find something and seems they are using a script. How do I block this kind of behaviour? I though of blocking the IP request, at least for a given time. Keeping in mind that: Request intervals seems legitimate (at least I think so). I don't want to end blocking a search engine bot, which may find 404 urls too (and that's a different problem, I know). ¿Do they use always same IP?

    Read the article

  • How is incoming SMTP mail being delivered despite blocked port

    - by Josh
    I setup a MX mail server, everything works despite port 25 being blocked, I'm stumped as to why I am able to receive email with this setup, and what the consequences might be if I leave it this way. Here are the details: Connections to SMTP over port 25 and 587 both reliably connect over my local network. Connections to SMTP over port 25 are blocked from external IPs (the ISP is blocking the port). Connections to Submission SMTP over port 587 from external IPs are reliable. Emails sent from gmail, yahoo, and a few other addresses all are being delivered. I haven't found an email provider that fails to deliver mail to my MX. So, with port 25 blocked, I am assuming other MTA servers fallback to port 587, otherwise I can't imagine how the mail is received. I know port 25 shouldn't be blocked, but so far it works. Are there mail servers that this will not work with? Where can I find more about how this is working? -- edit More technical detail, to validate that I'm not missing something silly. Obviously in the transcript below I've replaced my actual domain with example.com. # DNS MX record points to the A record. $ dig example.com MX +short 1 example.com $ dig example.com A +short <Public IP address> # From a public server (not my ISP hosting the mail server) # We see port 25 is blocked, but port 587 is open $ telnet example.com 25 Trying <public ip>... telnet: Unable to connect to remote host: Connection refused # Let's try openssl $ openssl s_client -starttls smtp -crlf -connect example.com:25 connect: Connection refused connect:errno=111 # Again from a public server, we see port 587 is open $ telnet example.com 587 Trying <public ip>... Connected to example.com. Escape character is '^]'. 220 example.com ESMTP Postfix ehlo example.com 250-example.com 250-PIPELINING 250-SIZE 10485760 250-VRFY 250-ETRN 250-STARTTLS 250-ENHANCEDSTATUSCODES 250-8BITMIME 250-DSN 250-BINARYMIME 250 CHUNKING quit 221 2.0.0 Bye Connection closed by foreign host. Here is a portion from the mail log when receiving a message from gmail: postfix/postscreen[93152]: CONNECT from [209.85.128.49]:48953 to [192.168.0.10]:25 postfix/postscreen[93152]: PASS NEW [209.85.128.49]:48953 postfix/smtpd[93160]: connect from mail-qe0-f49.google.com[209.85.128.49] postfix/smtpd[93160]: 7A8C31C1AA99: client=mail-qe0-f49.google.com[209.85.128.49] The log shows that a connection was made to the local IP on port 25 (I'm not doing any port mapping, so it is port 25 on the public IP too). Seeing this leads me to hypothesize that the ISP block on port 25 only occurs when a connection is made from an IP address that is not known to be a mail server. Any other theories?

    Read the article

  • How to do port forwarding in D-link Glb802c?

    - by Manish
    I have some questions about port forwarding on my D-Link Router GLB-802C. For example: My local machine's IP is 117.1.1.81 My router's IP is 117.1.1.1 My Public (Web) IP is 117.16.1.1 My questions are: What will be my Global Address 'To'? What will be my Global Address 'From'? In Destination Port "From" and "To" what do I select in the drop down list and port no for forwarding HTTP traffic (for my website)? In Local Port, what do I select in drop down list and port no?

    Read the article

  • How to do port forwarding in D-link Glb802c?

    - by Manish
    I have some questions about port forwarding on my D-Link Router GLB-802C. For example: My local machine's IP is 117.1.1.81 My router's IP is 117.1.1.1 My Public (Web) IP is 117.16.1.1 My questions are: What will be my Global Address 'To'? What will be my Global Address 'From'? In Destination Port "From" and "To" what do I select in the drop down list and port no for forwarding HTTP traffic (for my website)? In Local Port, what do I select in drop down list and port no?

    Read the article

  • What's the best way to forward traffic on a specific port to another machine?

    - by Ankit
    The setup I have is this: [client01] <-A-> [server01] <-B-> [server02] client01 can access port 9300 on server01 (connection A). server01 can access port 9300 on server02 (connection B). What's the best way to make all traffic on port 9300 to server01 go to port 9300 on server02? I can successfully do this with an ssh tunnel from client01 to server01 to server02, but I don't want to have to run ssh on client01. When I ssh from server01 to server02 forwarding port 9300 (ssh -g -L9300:localhost:9300 server02 on server01), it doesn't work -- am I using the wrong command?

    Read the article

  • threaded serial port IOException when writing

    - by John McDonald
    Hi, I'm trying to write a small application that simply reads data from a socket, extracts some information (two integers) from the data and sends the extracted information off on a serial port. The idea is that it should start and just keep going. In short, it works, but not for long. After a consistently short period I start to receive IOExceptions and socket receive buffer is swamped. The thread framework has been taken from the MSDN serial port example. The delay in send(), readThread.Join(), is an effort to delay read() in order to allow serial port interrupt processing a chance to occur, but I think I've misinterpreted the join function. I either need to sync the processes more effectively or throw some data away as it comes in off the socket, which would be fine. The integer data is controlling a pan tilt unit and I'm sure four times a second would be acceptable, but not sure on how to best acheive either, any ideas would be greatly appreciated, cheers. using System; using System.Collections.Generic; using System.Text; using System.IO.Ports; using System.Threading; using System.Net; using System.Net.Sockets; using System.IO; namespace ConsoleApplication1 { class Program { static bool _continue; static SerialPort _serialPort; static Thread readThread; static Thread sendThread; static String sendString; static Socket s; static int byteCount; static Byte[] bytesReceived; // synchronise send and receive threads static bool dataReceived; const int FIONREAD = 0x4004667F; static void Main(string[] args) { dataReceived = false; readThread = new Thread(Read); sendThread = new Thread(Send); bytesReceived = new Byte[16384]; // Create a new SerialPort object with default settings. _serialPort = new SerialPort("COM4", 38400, Parity.None, 8, StopBits.One); // Set the read/write timeouts _serialPort.WriteTimeout = 500; _serialPort.Open(); string moveMode = "CV "; _serialPort.WriteLine(moveMode); s = null; IPHostEntry hostEntry = Dns.GetHostEntry("localhost"); foreach (IPAddress address in hostEntry.AddressList) { IPEndPoint ipe = new IPEndPoint(address, 10001); Socket tempSocket = new Socket(ipe.AddressFamily, SocketType.Stream, ProtocolType.Tcp); tempSocket.Connect(ipe); if (tempSocket.Connected) { s = tempSocket; s.ReceiveBufferSize = 16384; break; } else { continue; } } readThread.Start(); sendThread.Start(); while (_continue) { Thread.Sleep(10); ;// Console.WriteLine("main..."); } readThread.Join(); _serialPort.Close(); s.Close(); } public static void Read() { while (_continue) { try { //Console.WriteLine("Read"); if (!dataReceived) { byte[] outValue = BitConverter.GetBytes(0); // Check how many bytes have been received. s.IOControl(FIONREAD, null, outValue); uint bytesAvailable = BitConverter.ToUInt32(outValue, 0); if (bytesAvailable > 0) { Console.WriteLine("Read thread..." + bytesAvailable); byteCount = s.Receive(bytesReceived); string str = Encoding.ASCII.GetString(bytesReceived); //str = Encoding::UTF8->GetString( bytesReceived ); string[] split = str.Split(new Char[] { '\t', '\r', '\n' }); string filteredX = (split.GetValue(7)).ToString(); string filteredY = (split.GetValue(8)).ToString(); string[] AzSplit = filteredX.Split(new Char[] { '.' }); filteredX = (AzSplit.GetValue(0)).ToString(); string[] ElSplit = filteredY.Split(new Char[] { '.' }); filteredY = (ElSplit.GetValue(0)).ToString(); // scale values int x = (int)(Convert.ToInt32(filteredX) * 1.9); string scaledAz = x.ToString(); int y = (int)(Convert.ToInt32(filteredY) * 1.9); string scaledEl = y.ToString(); String moveAz = "PS" + scaledAz + " "; String moveEl = "TS" + scaledEl + " "; sendString = moveAz + moveEl; dataReceived = true; } } } catch (TimeoutException) {Console.WriteLine("timeout exception");} catch (NullReferenceException) {Console.WriteLine("Read NULL reference exception");} } } public static void Send() { while (_continue) { try { if (dataReceived) { // sleep Read() thread to allow serial port interrupt processing readThread.Join(100); // send command to PTU dataReceived = false; Console.WriteLine(sendString); _serialPort.WriteLine(sendString); } } catch (TimeoutException) { Console.WriteLine("Timeout exception"); } catch (IOException) { Console.WriteLine("IOException exception"); } catch (NullReferenceException) { Console.WriteLine("Send NULL reference exception"); } } } } }

    Read the article

  • Difference between PORT and LATCH on PIC 18F

    - by acemtp
    I already read the datasheet and google but I still don't understand something. In my case, I set PIN RC6 of a PIC18F26K20 in INPUT mode: TRISCbits.TRISC6 = 1; Then I read the value with PORT and LATCH and I have different value! v1 = LATCbits.LATC6; v2 = PORTCbits.RC6; v1 gives me 0 where v2 gives 1. Is it normal? In which case we have to use PORT and in which case LATCH?

    Read the article

  • Receiving messages part by part from serial port using c#

    - by karthik
    I am using the below code to receive the messages from serial port using c# void comPort_DataReceived(object sender, SerialDataReceivedEventArgs e) { if (comPort.IsOpen == true) { string msg = comPort.ReadExisting(); MessageBox.Show(msg.Trim()); } } The problem is, i am getting the messages part by part. Like, if u send "Hello, How are you" I am receiving it word by word. I want that in a single stretch. How can i do ?? Also, is it possible to retrieve the port name from which the application is sending and receiving messages ?

    Read the article

  • Serial port determinism

    - by Matt Green
    This seems like a simple question, but it is difficult to search for. I need to interface with a device over the serial port. In the event my program (or another) does not finish writing a command to the device, how do I ensure the next run of the program can successfully send a command? Example: The foo program runs and begins writing "A_VERY_LONG_COMMAND" The user terminates the program, but the program has only written, "A_VERY" The user runs the program again, and the command is resent. Except, the device sees "A_VERYA_VERY_LONG_COMMAND," which isn't what we want. Is there any way to make this more deterministic? Serial port programming feels very out-of-control due to issues like this.

    Read the article

  • Multiple port asynchronous I/O over serialport in C#

    - by firoso
    I'm trying to write a test application for serial I/O (RS-232) with multiple units in C# and I'm running into an issue with my lack of threading experience so I'm soliciting feedback for a best known method. I've got a pool of COM ports COM1-16 each of which can read/write at any time and I need to be able to manage them simultaneously. Is this a situation for a thread pool? What is some guidance on structuring this applet? Edit: Upon review I was wondering is I really even need to do asynchronous threads here, I could just maintain states for each COM-port and do flow logic (i.e., statemachine) for each COM-port individually.

    Read the article

  • Getting wrong serial-port names from bluetoothdevice (c#)

    - by wurlog
    To get all avaliable Serialports from the system i use the following command. SerialPort.GetPortNames It works fine for the mainboard serial port, but with the bluetooth device i get the wrong portnames. For Example: Instead of COM7 i get sometimes COM70 or COM7ö. Its always 1 letter to much. any suggestens? PS: I am using newest Visual Studio Express in Windows 7 PPS: The dirty hack to cut the last letter didn't work because i don't know which one is the bluetooth serial port (with various bluetoothstick or devices it changes the number of the comport) and after trying various sticks i reached COM10, ergo COM100 or COM10f

    Read the article

  • Understand ACTV mode and the PORT command

    - by Ramy
    Hello, I'm the part time FTP server administrator (with no real full-time admin). We currently only allow ACTV mode connections. Some of our clients have had issues with this but for the most part they've been ok using ACTV. For the few who aren't, we've been able to push the data over to their servers from ours. there is one client in particular however who is currently having trouble. He is using file-zilla and issuing a PORT command. First, does using the PORT command imply that you are in ACTV mode? Second is there a way in FileZilla to explicitly change to ACTV mode? Thanks for the help, _Ramy

    Read the article

  • How to apply encoding when reading from a serial port

    - by rross
    I'm reading data from a serial port. I read this posting: http://social.msdn.microsoft.com/Forums/en-US/vbgeneral/thread/a709d698-5099-4e37-9e10-f66ff22cdd1e He is writing about many of the issues I have encounter, but in his writing he refers to using: System.Text.Encoding.GetEncoding("Windows-1252"). The problem I'm having is when and how to apply this. There are three potitional spots in my opinion. When the serial port object is define: private SerialPort comport = new SerialPort(); The Event handler: comport.DataReceived += new SerialDataReceivedEventHandler(port_DataReceived); Or when reading the data: string data = comport.ReadExisting(); No matter where I add it. I seem to get errors. How would one use Encoding?

    Read the article

  • How to read from port#### on home IP 127.0.0.1 [SOLVED]

    - by Ree
    I have a program that sends data to the home IP to the port####. I want to access this and make it readable data. Maybe in C#? I haven't tried doing this before and I have only a vague idea of doing sockets. Any ideas as to how I can manage this? Thanks - Ree EDIT The program I'm trying access is a UDP. Therefore it's a UDP port reader I need to incorporate on another program. "####" < is just any random number. SOLUTION: http://msdn.microsoft.com/en-us/library/tst0kwb1.aspx

    Read the article

  • How to run a WebPy server on port 8080 using DDNS of dlink router and to access this site from internet?

    - by nuke1010
    I have two major issue with setting up a web server using my dlink DIR-600L router. Issue 1: I run a WebPy server on port 8080. But the DDNS service providers (like dlinkddns.com or dyndns.org) only allows port 80. I can run the server in port 80 with sudo command. But my server become vulnerable if i give root access. So I tried port forwarding in the router and server. But no use. I don't know if I done that correctly. Issue 2: Even though the server runs on port 80, I can access my site from my local machines only using registered domain names ( say, nikz.dyndns.org). No one on internet cannot load this site even when its totally up. As I observed server log, the request from other clients never reached my server. I need to run this server on port 8080 and i need to access this site from internet. How can I do it? any idea?

    Read the article

  • Auto blocking attacking IP address

    - by dong
    This is to share my PowerShell code online. I original asked this question on MSDN forum (or TechNet?) here: http://social.technet.microsoft.com/Forums/en-US/winserversecurity/thread/f950686e-e3f8-4cf2-b8ec-2685c1ed7a77 In short, this is trying to find attacking IP address then add it into Firewall block rule. So I suppose: 1, You are running a Windows Server 2008 facing the Internet. 2, You need to have some port open for service, e.g. TCP 21 for FTP; TCP 3389 for Remote Desktop. You can see in my code I’m only dealing with these two since that’s what I opened. You can add further port number if you like, but the way to process might be different with these two. 3, I strongly suggest you use STRONG password and follow all security best practices, this ps1 code is NOT for adding security to your server, but reduce the nuisance from brute force attack, and make sys admin’s life easier: i.e. your FTP log won’t hold megabytes of nonsense, your Windows system log will not roll back and only can tell you what happened last month. 4, You are comfortable with setting up Windows Firewall rules, in my code, my rule has a name of “MY BLACKLIST”, you need to setup a similar one, and set it to BLOCK everything. 5, My rule is dangerous because it has the risk to block myself out as well. I do have a backup plan i.e. the DELL DRAC5 so that if that happens, I still can remote console to my server and reset the firewall. 6, By no means the code is perfect, the coding style, the use of PowerShell skills, the hard coded part, all can be improved, it’s just that it’s good enough for me already. It has been running on my server for more than 7 MONTHS. 7, Current code still has problem, I didn’t solve it yet, further on this point after the code. :)    #Dong Xie, March 2012  #my simple code to monitor attack and deal with it  #Windows Server 2008 Logon Type  #8: NetworkCleartext, i.e. FTP  #10: RemoteInteractive, i.e. RDP    $tick = 0;  "Start to run at: " + (get-date);    $regex1 = [regex] "192\.168\.100\.(?:101|102):3389\s+(\d+\.\d+\.\d+\.\d+)";  $regex2 = [regex] "Source Network Address:\t(\d+\.\d+\.\d+\.\d+)";    while($True) {   $blacklist = @();     "Running... (tick:" + $tick + ")"; $tick+=1;    #Port 3389  $a = @()  netstat -no | Select-String ":3389" | ? { $m = $regex1.Match($_); `    $ip = $m.Groups[1].Value; if ($m.Success -and $ip -ne "10.0.0.1") {$a = $a + $ip;} }  if ($a.count -gt 0) {    $ips = get-eventlog Security -Newest 1000 | Where-Object {$_.EventID -eq 4625 -and $_.Message -match "Logon Type:\s+10"} | foreach { `      $m = $regex2.Match($_.Message); $ip = $m.Groups[1].Value; $ip; } | Sort-Object | Tee-Object -Variable list | Get-Unique    foreach ($ip in $a) { if ($ips -contains $ip) {      if (-not ($blacklist -contains $ip)) {        $attack_count = ($list | Select-String $ip -SimpleMatch | Measure-Object).count;        "Found attacking IP on 3389: " + $ip + ", with count: " + $attack_count;        if ($attack_count -ge 20) {$blacklist = $blacklist + $ip;}      }      }    }  }      #FTP  $now = (Get-Date).AddMinutes(-5); #check only last 5 mins.     #Get-EventLog has built-in switch for EventID, Message, Time, etc. but using any of these it will be VERY slow.  $count = (Get-EventLog Security -Newest 1000 | Where-Object {$_.EventID -eq 4625 -and $_.Message -match "Logon Type:\s+8" -and `              $_.TimeGenerated.CompareTo($now) -gt 0} | Measure-Object).count;  if ($count -gt 50) #threshold  {     $ips = @();     $ips1 = dir "C:\inetpub\logs\LogFiles\FPTSVC2" | Sort-Object -Property LastWriteTime -Descending `       | select -First 1 | gc | select -Last 200 | where {$_ -match "An\+error\+occured\+during\+the\+authentication\+process."} `        | Select-String -Pattern "(\d+\.\d+\.\d+\.\d+)" | select -ExpandProperty Matches | select -ExpandProperty value | Group-Object `        | where {$_.Count -ge 10} | select -ExpandProperty Name;       $ips2 = dir "C:\inetpub\logs\LogFiles\FTPSVC3" | Sort-Object -Property LastWriteTime -Descending `       | select -First 1 | gc | select -Last 200 | where {$_ -match "An\+error\+occured\+during\+the\+authentication\+process."} `        | Select-String -Pattern "(\d+\.\d+\.\d+\.\d+)" | select -ExpandProperty Matches | select -ExpandProperty value | Group-Object `        | where {$_.Count -ge 10} | select -ExpandProperty Name;     $ips += $ips1; $ips += $ips2; $ips = $ips | where {$_ -ne "10.0.0.1"} | Sort-Object | Get-Unique;         foreach ($ip in $ips) {       if (-not ($blacklist -contains $ip)) {        "Found attacking IP on FTP: " + $ip;        $blacklist = $blacklist + $ip;       }     }  }        #Firewall change <# $current = (netsh advfirewall firewall show rule name="MY BLACKLIST" | where {$_ -match "RemoteIP"}).replace("RemoteIP:", "").replace(" ","").replace("/255.255.255.255",""); #inside $current there is no \r or \n need remove. foreach ($ip in $blacklist) { if (-not ($current -match $ip) -and -not ($ip -like "10.0.0.*")) {"Adding this IP into firewall blocklist: " + $ip; $c= 'netsh advfirewall firewall set rule name="MY BLACKLIST" new RemoteIP="{0},{1}"' -f $ip, $current; Invoke-Expression $c; } } #>    foreach ($ip in $blacklist) {    $fw=New-object –comObject HNetCfg.FwPolicy2; # http://blogs.technet.com/b/jamesone/archive/2009/02/18/how-to-manage-the-windows-firewall-settings-with-powershell.aspx    $myrule = $fw.Rules | where {$_.Name -eq "MY BLACKLIST"} | select -First 1; # Potential bug here?    if (-not ($myrule.RemoteAddresses -match $ip) -and -not ($ip -like "10.0.0.*"))      {"Adding this IP into firewall blocklist: " + $ip;         $myrule.RemoteAddresses+=(","+$ip);      }  }    Wait-Event -Timeout 30 #pause 30 secs    } # end of top while loop.   Further points: 1, I suppose the server is listening on port 3389 on server IP: 192.168.100.101 and 192.168.100.102, you need to replace that with your real IP. 2, I suppose you are Remote Desktop to this server from a workstation with IP: 10.0.0.1. Please replace as well. 3, The threshold for 3389 attack is 20, you don’t want to block yourself just because you typed your password wrong 3 times, you can change this threshold by your own reasoning. 4, FTP is checking the log for attack only to the last 5 mins, you can change that as well. 5, I suppose the server is serving FTP on both IP address and their LOG path are C:\inetpub\logs\LogFiles\FPTSVC2 and C:\inetpub\logs\LogFiles\FPTSVC3. Change accordingly. 6, FTP checking code is only asking for the last 200 lines of log, and the threshold is 10, change as you wish. 7, the code runs in a loop, you can set the loop time at the last line. To run this code, copy and paste to your editor, finish all the editing, get it to your server, and open an CMD window, then type powershell.exe –file your_powershell_file_name.ps1, it will start running, you can Ctrl-C to break it. This is what you see when it’s running: This is when it detected attack and adding the firewall rule: Regarding the design of the code: 1, There are many ways you can detect the attack, but to add an IP into a block rule is no small thing, you need to think hard before doing it, reason for that may include: You don’t want block yourself; and not blocking your customer/user, i.e. the good guy. 2, Thus for each service/port, I double check. For 3389, first it needs to show in netstat.exe, then the Event log; for FTP, first check the Event log, then the FTP log files. 3, At three places I need to make sure I’m not adding myself into the block rule. –ne with single IP, –like with subnet.   Now the final bit: 1, The code will stop working after a while (depends on how busy you are attacked, could be weeks, months, or days?!) It will throw Red error message in CMD, don’t Panic, it does no harm, but it also no longer blocking new attack. THE REASON is not confirmed with MS people: the COM object to manage firewall, you can only give it a list of IP addresses to the length of around 32KB I think, once it reaches the limit, you get the error message. 2, This is in fact my second solution to use the COM object, the first solution is still in the comment block for your reference, which is using netsh, that fails because being run from CMD, you can only throw it a list of IP to 8KB. 3, I haven’t worked the workaround yet, some ideas include: wrap that RemoteAddresses setting line with error checking and once it reaches the limit, use the newly detected IP to be the list, not appending to it. This basically reset your block rule to ground zero and lose the previous bad IPs. This does no harm as it sounds, because given a certain period has passed, any these bad IPs still not repent and continue the attack to you, it only got 30 seconds or 20 guesses of your password before you block it again. And there is the benefit that the bad IP may turn back to the good hands again, and you are not blocking a potential customer or your CEO’s home pc because once upon a time, it’s a zombie. Thus the ZEN of blocking: never block any IP for too long. 4, But if you insist to block the ugly forever, my other ideas include: You call MS support, ask them how can we set an arbitrary length of IP addresses in a rule; at least from my experiences at the Forum, they don’t know and they don’t care, because they think the dynamic blocking should be done by some expensive hardware. Or, from programming perspective, you can create a new rule once the old is full, then you’ll have MY BLACKLIST1, MY  BLACKLIST2, MY BLACKLIST3, … etc. Once in a while you can compile them together and start a business to sell your blacklist on the market! Enjoy the code! p.s. (PowerShell is REALLY REALLY GREAT!)

    Read the article

  • What is the rules of ports?

    - by Jake
    Hi, I mean the port to connecting.. just like SSH port, nginx port, etc. Im not clear about the port. So far I can see port running not more than 5 characters (port xxxxx). So, when choosing port number, what is the rules and the character limit of port? Is 5 characters the maximum? Thanks.

    Read the article

< Previous Page | 12 13 14 15 16 17 18 19 20 21 22 23  | Next Page >