  • How to perform fresh linux install while preserving software raid and user accounts

    - by slayton
    I have a system with two software raid arrays. The OS is Ubuntu 9.04 and is no longer receiving updates. I'd like to update the system to 12.04 rather than trying to do the automatic update from 9.04-> 9.10-> ... -> 12.04. My main drive has 2 partitions that are mounted at / and /home. Is it possible to do a fresh install of linux to the partition where / is mounted while preserving user accounts and preferences (such as passwords, home dir locations, etc...)? Additionally what do I need to do to keep my software raid array intact following the OS re-install?

    Read the article

  • choosing the right RAID level for PostgresQL database

    - by Sergey
    Hi, I got an disk array appliance of 8 disks 1T each (UltraStor RS8IP4). It will be used solely by PostgresQL database and I am trying to choose the best RAID level for it. The most priority is for read performance since we operate large data sets (tables, indexes) and we do lots of searches/scans. With the old disks that we have now the most slowdowns happen on SELECTs. Fault tolerance is less important, it can be 1 or 2 disks. Space is the least important factor. Even 1T will be enough. Which RAID level would you recommend in this situation. The current options are 60, 50 and 10, but probably other options can be even better.

    Read the article

  • GRUB2 UEFI booting from LVM on RAID (with XEN)

    - by pavian
    I'm experimenting with booting root fs from LVM volume inside the raid (mdraid superblock 1.x) via UEFI with GRUB2. Also I'm using Xen hypervisor. From grub command line I can see my lvm volume (ls command) but I got kernel panic due to "unable to mount root fs". I saw a note in this article telling it's probably impossible to boot root fs from raid via UEFI, but I don't understand the reason why not. Is it possible to boot linux with this configuration without the initramfs (which I don't won't to use)?

    Read the article

  • Dell Power Edge R515 - Replacing a Bad Hard Drive in a RAID

    - by LonnieBest
    I've ordered a new hard drive to replace a bad one in a Dell Power Edge R515. The manual covers obvious topics regarding physical replacing of hard drives, but I've never done this before on a production server where RAID is involved. I've heard people talk about this topic, and I've heard that some servers have RAID controllers that are smart enough to allow you to just put in the new drive (hot swap), and then the server will know automatically how to rebuild that drive to be what the old one was to the system. Where do I find the proper procedure for replacing a failed hard drive on a live production Dell Power Edge R515? Can someone with experience tell me how easy or hard this usually is?

    Read the article

  • Hardware RAID 0 without OS re-installation

    - by sterz
    I have Ubuntu & Windows 7 installed on my hdd. Can I mirror the image of the hdd to the second identical drive? Is this not recommended (i.e have to re-install every OS)? If it is okay to mirror, is there anything else to do to make hw RAID 0 work? Does RAID 0 have the same risk as a single drive? What sector size would you recommend for read/write/extract video files (mostly each around 2 GB)?

    Read the article

  • growing EBS RAID volume

    - by Ryan Fernandes
    I've created a RAID0 configuration with two 1GB EBS volumes, mounted at /dev/md0 using mdadm and formatted with XFS Next, I copied some files over to fill the volume to around 30% of its capacity (of 2GB) I then created snapshots of the volumes using ec2-consistent-snapshot and created volumes of the said snapshots but specified the volume size to be 2GB (effective doubling the capacity on each disk) I then spun up a new instance, assembled the RAID0 configuration on /dev/md0 from the 2 volumes mentioned above and mount it to /vol df -hT showed /vol as 2GB (as expected) Now I ran sudo xfs_growfs -d /vol. The command completed normally but reported blocks changed from 523776 to 524160 (only!) and df -hT still showed /vol as 2GB (instead of the expected 4GB) I rebooted, remounted, reassembled the RAID but it still reports the old size. EDIT: trying to grow the RAID using mdadm --grow yields mdadm: raid0 array /dev/md0 cannot be reshaped Is there any other way I can grow a RAID0 array?

    Read the article

  • Benefits of a RAID BBU in addition to a double UPS + PS system

    - by Wikser
    Today I roughly measured the benefits of enabling write-back on the RAID controller on a server at work. It got no RAID battery-backup-unit (BBU) so the write-cache is currently disabled. As the server is not used to capacity (by far), the results in most test were spectacular, e.g.: Database CRUD: before 35s, after 4s Saving a 1MB Excel file: before: 20s (!), after: 0.5s Of course having a BBU is always recommended, but what are the main benefits of installing a BBU to a system, which got redundant power supplies and is attached to UPSs? Does this depend on the type of the system (database, file, terminal)? What is a realistic fail scenario which could be prevented by a BBU? Thanks in advance!

    Read the article

  • HighPoint RAID Controller can't see drives

    - by Satellite
    I've just built a system with a HighPoint 2720 RAID controller. Everything appears to be OK, except that the controller doesn't see any of my drives - the RAID BIOS displays "ERROR. No Suitable disks". I have tried a WD SATA, Seagate SATA, and OCZ Vertex 3 SATA. I am using MiniSAS to 4x SATA breakout cables. How do I get this working? I've tried to sign up for HighPoint support, but their support site doesn't appear to be functioning correctly.

    Read the article

  • Raid1+0: create stripe over two /dev/mdx on partition or not?

    - by Chris
    Given that I haven't found a way to define how a Raid10 is created with mdadm, i went the Raid1+0 solution. How to display/define Mirror/Stripping pairs with mdadm mdadm --create /dev/md0 --level=1 --raid-devices=2 /dev/sda1 /dev/sdf1 mdadm --create /dev/md1 --level=1 --raid-devices=2 /dev/sdg1 /dev/sdh1 mdadm --create /dev/md10 --level=0 --raid-devices=2 /dev/md0 /dev/md1 My question is about the stripe. For the mirror I create a primary partition over the full HD and set partition type to FD. So, should I do the same for the Stripe? Create partition on /dev/md0 and /dev/md1 (primary over full 'HDD', set partition type correctly) and then do the stripe on the partition? Is there a correct way here or are there any advantages/disadvantages to a solution? Thank you

    Read the article

  • Most efficient RAID configuration with 6 disks?

    - by Bob King
    I have a hand-me-down server that I'm setting up at home and it's got 6 72Gb hard disks (as well as 2 18Gb drives that I'm using for the OS). What is the best way to configure those 6 drives? Should I RAID 5 or 6, or go with something simpler, like mirroring? I'm planning to use it to hold a source control repository, and possibly data for a development SQL server. The machine has a hardware raid controller. It is an old IBM server.

    Read the article

  • RAID 1 in ubuntu 12.04

    - by Bavly Hanna
    Right now I have a small file server to which I have loaded ubuntu 12.04 desktop on a small 160gb harddrive. This harddrive is the primary drive from which the OS boots. I want to move all my data to my file server so it can be shared on the network (contain in 2x2TB harddrives in my desktop. The 2TB drivers are in raid 1 (hardware). I simply want to move them to the file server and set it up so that they are in software raid 1. If at all possible I'd like to be able to do this without losing any info on the drives. I've searched around and the guides i find describe raiding drives for boot driver, but these wouldn't be boot drives just regular storage drives. If someone could tell me how to perform this or point me in the right direction it would be much appreciated.

    Read the article

  • Replacing a non-failing drive in a RAID-0 array [migrated]

    - by TallFurryMan
    I have a Windows 7 machine booting on a RAID-0 pair of 500GB disks, controlled by an ICH9R. One of those is indicating an end-To-end SMART failure. I added a spare disk as a temporary workaround, before receiving another to replace the failing one (prices are awful these days). The RAID-0 rebuilt on the spare and dropped the failing one from the array, as expected. Now that I received the new drive, what are my options to reintegrate it in the array? My first thought was to simply clone the temporary disk to the new one while the array is offline, but shouldn't there be a way to force a second rebuild, just as if the temporary drive had a warning, and drop that temporary from the array?

    Read the article

  • linux raid 1: right after replacing and syncing one drive, the other disk fails - understanding what is going on with mdstat/mdadm

    - by devicerandom
    We have an old RAID 1 Linux server (Ubuntu Lucid 10.04), with four partitions. A few days ago /dev/sdb failed, and today we noticed /dev/sda had pre-failure ominous SMART signs (~4000 reallocated sector count). We replaced /dev/sdb this morning and rebuilt the RAID on the new drive, following this guide: http://www.howtoforge.com/replacing_hard_disks_in_a_raid1_array Everything went smooth until the very end. When it looked like it was finishing to synchronize the last partition, the other old one failed. At this point I am very unsure of the state of the system. Everything seems working and the files seem to be all accessible, just as if it synchronized everything, but I'm new to RAID and I'm worried about what is going on. The /proc/mdstat output is: Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10] md3 : active raid1 sdb4[2](S) sda4[0] 478713792 blocks [2/1] [U_] md2 : active raid1 sdb3[1] sda3[2](F) 244140992 blocks [2/1] [_U] md1 : active raid1 sdb2[1] sda2[2](F) 244140992 blocks [2/1] [_U] md0 : active raid1 sdb1[1] sda1[2](F) 9764800 blocks [2/1] [_U] unused devices: <none> The order of [_U] vs [U_]. Why aren't they consistent along all the array? Is the first U /dev/sda or /dev/sdb? (I tried looking on the web for this trivial information but I found no explicit indication) If I read correctly for md0, [_U] should be /dev/sda1 (down) and /dev/sdb1 (up). But if /dev/sda has failed, how can it be the opposite for md3 ? I understand /dev/sdb4 is now spare because probably it failed to synchronize it 100%, but why does it show /dev/sda4 as up? Shouldn't it be [__]? Or [_U] anyway? The /dev/sda drive now cannot even be accessed by SMART anymore apparently, so I wouldn't expect it to be up. What is wrong with my interpretation of the output? I attach also the outputs of mdadm --detail for the four partitions: /dev/md0: Version : 00.90 Creation Time : Fri Jan 21 18:43:07 2011 Raid Level : raid1 Array Size : 9764800 (9.31 GiB 10.00 GB) Used Dev Size : 9764800 (9.31 GiB 10.00 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 0 Persistence : Superblock is persistent Update Time : Tue Nov 5 17:27:33 2013 State : clean, degraded Active Devices : 1 Working Devices : 1 Failed Devices : 1 Spare Devices : 0 UUID : a3b4dbbd:859bf7f2:bde36644:fcef85e2 Events : 0.7704 Number Major Minor RaidDevice State 0 0 0 0 removed 1 8 17 1 active sync /dev/sdb1 2 8 1 - faulty spare /dev/sda1 /dev/md1: Version : 00.90 Creation Time : Fri Jan 21 18:43:15 2011 Raid Level : raid1 Array Size : 244140992 (232.83 GiB 250.00 GB) Used Dev Size : 244140992 (232.83 GiB 250.00 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 1 Persistence : Superblock is persistent Update Time : Tue Nov 5 17:39:06 2013 State : clean, degraded Active Devices : 1 Working Devices : 1 Failed Devices : 1 Spare Devices : 0 UUID : 8bcd5765:90dc93d5:cc70849c:224ced45 Events : 0.1508280 Number Major Minor RaidDevice State 0 0 0 0 removed 1 8 18 1 active sync /dev/sdb2 2 8 2 - faulty spare /dev/sda2 /dev/md2: Version : 00.90 Creation Time : Fri Jan 21 18:43:19 2011 Raid Level : raid1 Array Size : 244140992 (232.83 GiB 250.00 GB) Used Dev Size : 244140992 (232.83 GiB 250.00 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 2 Persistence : Superblock is persistent Update Time : Tue Nov 5 17:46:44 2013 State : clean, degraded Active Devices : 1 Working Devices : 1 Failed Devices : 1 Spare Devices : 0 UUID : 2885668b:881cafed:b8275ae8:16bc7171 Events : 0.2289636 Number Major Minor RaidDevice State 0 0 0 0 removed 1 8 19 1 active sync /dev/sdb3 2 8 3 - faulty spare /dev/sda3 /dev/md3: Version : 00.90 Creation Time : Fri Jan 21 18:43:22 2011 Raid Level : raid1 Array Size : 478713792 (456.54 GiB 490.20 GB) Used Dev Size : 478713792 (456.54 GiB 490.20 GB) Raid Devices : 2 Total Devices : 2 Preferred Minor : 3 Persistence : Superblock is persistent Update Time : Tue Nov 5 17:19:20 2013 State : clean, degraded Active Devices : 1 Working Devices : 2 Failed Devices : 0 Spare Devices : 1 Number Major Minor RaidDevice State 0 8 4 0 active sync /dev/sda4 1 0 0 1 removed 2 8 20 - spare /dev/sdb4 The active sync on /dev/sda4 baffles me. I am worried because if tomorrow morning I have to replace /dev/sda, I want to be sure what should I sync with what and what is going on. I am also quite baffled by the fact /dev/sda decided to fail exactly when the raid finished resyncing. I'd like to understand what is really happening. Thanks a lot for your patience and help. Massimo

    Read the article

  • SATA drive problems with two SIL RAID cards

    - by Jon Topper
    I've just put a second SiI 3114 SATARaid card in my home server so that I could add another pair of SATA drives and increase my storage space. Annoyingly, it doesn't seem to work: [ 32.816030] ata5: lost interrupt (Status 0x0) [ 32.816072] ata5.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [ 32.816091] ata5.00: cmd c8/00:08:00:00:00/00:00:00:00:00/e0 tag 0 dma 4096 in [ 32.816094] res 40/00:00:00:00:00/00:00:00:00:00/00 Emask 0x4 (timeout) [ 32.816101] ata5.00: status: { DRDY } [ 32.816117] ata5: hard resetting link [ 33.136082] ata5: SATA link down (SStatus 0 SControl 0) [ 36.060940] irq 18: nobody cared (try booting with the "irqpoll" option) [ 36.060949] Pid: 0, comm: swapper Not tainted 2.6.31-20-generic #58-Ubuntu [ 36.060954] Call Trace: [ 36.060977] [] ? printk+0x18/0x1c [ 36.060997] [] __report_bad_irq+0x27/0x90 [ 36.061005] [] note_interrupt+0x150/0x190 [ 36.061011] [] handle_fasteoi_irq+0xac/0xd0 [ 36.061023] [] handle_irq+0x18/0x30 [ 36.061029] [] do_IRQ+0x47/0xc0 [ 36.061042] [] ? irq_exit+0x50/0x70 [ 36.061058] [] ? smp_apic_timer_interrupt+0x57/0x90 [ 36.061065] [] common_interrupt+0x30/0x40 [ 36.061075] [] ? native_safe_halt+0x5/0x10 [ 36.061082] [] default_idle+0x46/0xd0 [ 36.061088] [] cpu_idle+0x8c/0xd0 [ 36.061103] [] rest_init+0x55/0x60 [ 36.061111] [] start_kernel+0x2e6/0x2ec [ 36.061117] [] ? unknown_bootoption+0x0/0x19e [ 36.061133] [] i386_start_kernel+0x7c/0x83 [ 36.061137] handlers: [ 36.061139] [] (sil_interrupt+0x0/0xb0) [ 36.061151] Disabling IRQ #18 [ 38.136014] ata5: hard resetting link [ 38.456022] ata5: SATA link down (SStatus 0 SControl 0) [ 43.456013] ata5: hard resetting link [ 43.776022] ata5: SATA link down (SStatus 0 SControl 0) [ 43.776035] ata5.00: disabled [ 43.776055] ata5.00: device reported invalid CHS sector 0 [ 43.776074] sd 4:0:0:0: [sde] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE [ 43.776082] sd 4:0:0:0: [sde] Sense Key : Aborted Command [current] [descriptor] [ 43.776092] Descriptor sense data with sense descriptors (in hex): [ 43.776097] 72 0b 00 00 00 00 00 0c 00 0a 80 00 00 00 00 00 [ 43.776112] 00 00 00 00 [ 43.776118] sd 4:0:0:0: [sde] Add. Sense: No additional sense information [ 43.776127] end_request: I/O error, dev sde, sector 0 [ 43.776136] Buffer I/O error on device sde, logical block 0 [ 43.776170] ata5: EH complete [ 43.776187] ata5.00: detaching (SCSI 4:0:0:0) root@core:~# cat /proc/interrupts CPU0 0: 47 IO-APIC-edge timer 1: 8 IO-APIC-edge i8042 6: 3 IO-APIC-edge floppy 7: 0 IO-APIC-edge parport0 8: 0 IO-APIC-edge rtc0 9: 0 IO-APIC-fasteoi acpi 14: 53069 IO-APIC-edge pata_sis 15: 53004 IO-APIC-edge pata_sis 17: 112265 IO-APIC-fasteoi sata_sil 18: 200002 IO-APIC-fasteoi sata_sil, SiS SI7012 19: 111140 IO-APIC-fasteoi eth0 20: 0 IO-APIC-fasteoi ohci_hcd:usb2 21: 0 IO-APIC-fasteoi ohci_hcd:usb3 23: 0 IO-APIC-fasteoi ehci_hcd:usb1 NMI: 0 Non-maskable interrupts LOC: 6650492 Local timer interrupts SPU: 0 Spurious interrupts CNT: 0 Performance counter interrupts PND: 0 Performance pending work RES: 0 Rescheduling interrupts CAL: 0 Function call interrupts TLB: 0 TLB shootdowns TRM: 0 Thermal event interrupts THR: 0 Threshold APIC interrupts MCE: 0 Machine check exceptions MCP: 160 Machine check polls ERR: 0 MIS: 0 root@core:~# lspci | grep Raid 00:09.0 RAID bus controller: Silicon Image, Inc. SiI 3114 [SATALink/SATARaid] Serial ATA Controller (rev 02) 00:0a.0 RAID bus controller: Silicon Image, Inc. SiI 3114 [SATALink/SATARaid] Serial ATA Controller (rev 02) root@core:~# lsb_release -a No LSB modules are available. Distributor ID: Ubuntu Description: Ubuntu 9.10 Release: 9.10 Codename: karmic root@core:~# uname -a Linux core.topper.me.uk 2.6.31-20-generic #58-Ubuntu SMP Fri Mar 12 05:23:09 UTC 2010 i686 GNU/Linux I've tried a combination of different kernel options (irqpoll, noapic, noacpi, pci=noapic) all to no avail. Does anyone have any bright ideas about how I can go about making this work? Swapping PCI cards around isn't an option as there are only two slots in this motherboard (an ASRock K7S41GX). The BIOS doesn't look to have too much in the way of configuration options regarding IRQ usage. Plan B is to ditch this server completely and buy a new QNAP for these drives to go in, but I was hoping to avoid doing this right now.

    Read the article

  • explain md's raid10,f2

    - by xenoterracide
    I know how most of the various RAID's work. But I stumbled on the recommended raid10,f2 mode while researching linux software raid. I don't really understand how it works on 2 or 3 disks. could someone explain it to me? or point me to a really good article that explains it?

    Read the article

  • Areca 1280ml RAID6 volume set failed

    - by Richard
    Today we hit some kind of worst case scenario and are open to any kind of good ideas. Here is our problem: We are using several dedicated storage servers to host our virtual machines. Before I continue, here are the specs: Dedicated Server Machine Areca 1280ml RAID controller, Firmware 1.49 12x Samsung 1TB HDDs We configured one RAID6-set with 10 discs that contains one logical volume. We have two hot spares in the system. Today one HDD failed. This happens from time to time, so we replaced it. Upon rebuilding a second disc failed. Normally this is no fun. We stopped heavy IO-operations to ensure a stable RAID rebuild. Sadly the hot-spare disc failed while rebuilding and the whole thing stopped. Now we have the following situation: The controller says that the raid set is rebuilding The controller says that the volume failed It is a RAID 6 system and two discs failed, so the data has to be intact, but we cannot bring the volume online again to access the data. While searching we found the following leads. I don't know whether they are good or bad: Mirroring all the discs to a second set of drives. So we would have the possibility to try different things without loosing more than we already have. Trying to rebuild the array in R-Studio. But we have no real experience with the software. Pulling all drives, rebooting the system, changing into the areca controller bios, reinserting the HDDs one-by-one. Some people are saying that the brought the system online by this. Some are saying that the effect is zero. Some say, that they blew the whole thing. Using undocumented areca commands like "rescue" or "LeVel2ReScUe". Contacting a computer forensics service. But whoa... primary estimates by phone exceeded 20.000€. That's why we would kindly ask for help. Maybe we are missing the obvious? And yes of course, we have backups. But some systems lost one week of data, thats why we'd like to get the system up and running again. Any help, suggestions and questions are more than welcome.

    Read the article

  • Does chunk size affect the read performance of a Linux md software RAID1 array?

    - by OldWolf
    This came up in relation to this question on determining chunk size of an existing RAID array. The general consensus seems to be that chunk size does not apply to RAID1 as it is not striped. On the other hand, the Linux RAID Wiki claims that it will have an affect on read performance. However, I cannot find any benchmarks testing/proving that. Can anyone point to conclusive documentation that it either does or does not affect read performance?

    Read the article

  • Adaptec 6405 RAID controller turned on red LED

    - by nn4l
    I have a server with an Adaptec 6405 RAID controller and 4 disks in a RAID 5 configuration. Staff in the data center called me because they noticed a red LED was turned on in one of the drive bays. I have then checked the status using 'arcconf getconfig 1' and I got the status message 'Logical devices/Failed/Degraded: 2/0/1'. The status of the logical devices was listed as 'Rebuilding'. However, I did not get any suspicious status of the affected physical device, the S.M.A.R.T. setting was 'no', the S.M.A.R.T. warnings were '0' and also 'arcconf getsmartstatus 1' returned no problems with any of the disk drives. The 'arcconf getlogs 1 events tabular' command gives lots of output (sorry, can't paste the log file here as I only have remote console access, I could post a screenshot though). Here are some sample entries: eventtype FSA_EM_EXPANDED_EVENT grouptype FSA_EXE_SCSI_GROUP subtype FSA_EXE_SCSI_SENSE_DATA subtypecode 12 cdb 28 00 17 c4 74 00 00 02 00 00 00 00 data 70 00 06 00 00 00 00 00 00 00 00 00 02 00 00 00 00 00 00 00 00 00 00 00 00 0 The 'arcconf getlogs 1 device tabular' command reports mediumErrors 1 for two of the disks. Today, I have checked the status of the controller again. Everything is back to normal, the controller status is now 'Logical devices/Failed/Degraded: 2/0/0', the logical devices are also all back to 'Optimal'. I was not able to check the LED status, my guess is that the red LED is off again. Now I have a lot of questions: what is a possible cause for the medium error, why it is not reported by the SMART log too? Should I replace the disk drives? They were purchased just a month ago. The rebuilding process took one or two days, is that normal? The disks are 2 TByte each and the storage system is mostly idling. the timestamp of the logs seem to show the moment of the log retrieval, not the moment of the incident. Please advise, all help is very appreciated.

    Read the article

  • RAID 5 - DELL 2850 and others

    - by Kiara
    I have installed Ubuntu on a DELL 2850 and I have configured an array of 5 disks (SCSI 73GB 10K) in RAID5. I wanted to simulate a drive error so in the middle of something I just took one of the drives out and put it back again after a bit. Then the drive shows an orange light and seems to be rebuilding but actually is taking hours and hours with no results. So I went to the PERC utility (Ctrl+M) and the disk shows "REBLD". But it never gets to an online state. So I went to Objects - Physical drives - Rebuilding - View rebuild process. And in here I can see a bar moving from 0%... but if I reboot before finishing and get into the PERC Utility again, it seems to start again rebuilding from 0% - so it is not rebuilding automatically. My concern is: what would happen in a real situation? Do I have to just switch the server off and go to the Perc utility to start the rebuilding manually? I thought the whole point was to have this done automatically and without the need of stopping the server. Or does it perhaps rebuild automatically indeed but needs to have enough time without rebooting because otherwise the rebuilding process will start from scratch? It seems to take more than 3h for a 73gb disk! My second question is: can I mix then hard drives? So if I have a RAID of 5x73GB 10K can I use different size (146GB) or speeds (15K)? Apparently someone said it is OK in here Poweredge 2850: replace disk with larger in RAID?

    Read the article

  • Raid-1 Western Digital Green AARS, cloning and WD Align Utility

    - by Jaguar
    Hello all, My current setup runs on top of 2x Western Digital 2500KS drives on Raid-1, using the motherboard's 780G raid controller, on WinXP. Everything is fine, but the drives are a bit noisy. I am considering buying 2x WD6400AARS disks which are the 640GB slower 'green' drives, but also feature the Advanced Formatting 4KB sectors. This means that for WinXP the partition will have to be aligned to work properly, else there is a performance penalty. There are 2 questions here: The Green drives from WD are all slower and are (according to WD) susceptible to drop-out's from the controller. Has anyone any experience in this matter? Is there a possibility the controller will drop a drive? If so, can i do anything about it? Secondly, western digital gives a utility to perform the alignment on the partition. The thing is, will the utility see the drives in question as the operating system only sees 1 logical disk? I will be making the transition using a cloning tool (most probably norton ghost) unless i don't find a solution or a clear answer, in which case i'll just buy a win 7 license and make a clean install... thx in advance

    Read the article

  • Ubuntu raid 1 write errors

    - by Micah
    I have an Ubuntu server set up with two SATA drives in a RAID 1 configuration with MDADM. The machine is used to record raw video, which involves a lot of writing to the disk. Sometimes during video recording the computer will crash, will the following errors in kern.log: Mar 15 10:39:41 video kernel: [414501.629864] ata2.00: exception Emask 0x10 SAct 0x0 SErr 0x400100 action 0x6 Mar 15 10:39:41 video kernel: [414501.629870] ata2.00: BMDMA stat 0x26 Mar 15 10:39:41 video kernel: [414501.629875] ata2.00: SError: { UnrecovData Handshk } Mar 15 10:39:41 video kernel: [414501.629880] ata2.00: failed command: WRITE DMA EXT Mar 15 10:39:41 video kernel: [414501.629889] ata2.00: cmd 35/00:00:28:6d:f6/00:04:06:00:00/e0 tag 0 dma 524288 out Mar 15 10:39:41 video kernel: [414501.629891] res 51/84:b1:77:6e:f6/84:02:06:00:00/e0 Emask 0x30 (host bus error) Mar 15 10:39:41 video kernel: [414501.629896] ata2.00: status: { DRDY ERR } Mar 15 10:39:41 video kernel: [414501.629899] ata2.00: error: { ICRC ABRT } Mar 15 10:39:41 video kernel: [414501.629910] ata2.00: hard resetting link Mar 15 10:39:41 video kernel: [414501.973009] ata2.01: hard resetting link Mar 15 10:39:41 video kernel: [414502.482642] ata2.00: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Mar 15 10:39:41 video kernel: [414502.482658] ata2.01: SATA link down (SStatus 0 SControl 300) Mar 15 10:39:41 video kernel: [414502.546160] ata2.00: configured for UDMA/133 Mar 15 10:39:41 video kernel: [414502.546203] ata2: EH complete Is this the result of faulty drives? Is software RAID just not performant enough for data rates ~15 MB/s, even with a quad-core i7? Thanks for your help. Edit: cat /proc/mdstat returns this: Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md0 : active raid1 sdb1[1] sda1[0] 976760768 blocks [2/2] [UU] unused devices: <none>

    Read the article

  • Slow parity initialization of RAID-5 array on HP Smart Array 411 controller

    - by Rob Nicholson
    On 29th October 2011, I built a RAID-5 array using 4 x 146.8GB Seagate SAS ST3146855SS drives running at 15k connected to a PowerEdge R515 with HP Smart Array P411 controller running Windows 2008 (so nothing particularly unusual). I know that parity initialisation of a RAID-5 array can take some time but it's still running after 2.5 weeks which seems a little unusual. I'd previously built another array on the same controller using 4 x 2TB SATA-2 drives and that did take a while to complete but a) I'm sure it was less than 2.5 weeks, b) that array was ~12 times bigger and c) during initialization, the percentrage slowly increased each day. At the moment, the status display for this new 2nd array simply says "Parity Initialization Status: In Progress" and it's said that since the start. It's this lack of change on the status that worries me the most - feels like it's not actually doing anything. Do you think something has gone wrong or am I being unpatient and for some reason, the status not increasing is normal? I kind of expected a much smaller array on faster drives (15k SAS versus 7.5k SATA-2) to build in a few days. This is our primary SAN running StarWind so my "have a play" options are very limited. This 2nd array is currently in use for one small virtual disk so I could shut the target machine down, move the virtual disk to another drive and try rebuilding.

    Read the article

  • Dell R320 RAID 10 with CacheCade

    - by Geekman
    I'm looking for a higher-performance build for our 1RU Dell R320 servers, in terms of IOPS. Right now I'm fairly settled on: 4 x 600 GB 3.5" 15K RPM SAS RAID 1+0 array This should give good performance, but if possible, I want to also add an SSD Cache into the mix, but I'm not sure if there's enough room? According to the tech-specs, there's only up to 4 total 3.5" drive bays available. Is there any way to fit at least a single SSD drive along-side the 4x3.5" drives? I was hoping there's a special spot to put the cache SSD drive (though from memory, I doubt there'd be room). Or am I right in thinking that the cache drives are simply drives plugged in "normally" just as any other drive, but are nominated as CacheCade drives in the PERC controller? Are there any options for having the 4x600GB RAID 10 array, and the SSD cache drive, too? Based on the tech-specs (with up to 8x2.5" drives), maybe I need to use 2.5" SAS drives, leaving another 4 bays spare, plenty of room for the SSD cache drive. Has anyone achieved this using 3.5" drives, somehow?

    Read the article

  • Rebuilding LVM after RAID recovery

    - by Xiong Chiamiov
    I have 4 disks RAID-5ed to create md0, and another 4 disks RAID-5ed to create md1. These are then combined via LVM to create one partition. There was a power outage while I was gone, and when I got back, it looked like one of the disks in md1 was out of sync - mdadm kept claiming that it only could find 3 of the 4 drives. The only thing I could do to get anything to happen was to use mdadm --create on those four disks, then let it rebuild the array. This seemed like a bad idea to me, but none of the stuff I had was critical (although it'd take a while to get it all back), and a thread somewhere claimed that this would fix things. If this trashed all of my data, then I suppose you can stop reading and just tell me that. After waiting four hours for the array to rebuild, md1 looked fine (I guess), but the lvm was complaining about not being able to find a device with the correct UUID, presumably because md1 changed UUIDs. I used the pvcreate and vgcfgrestore commands as documented here. Attempting to run an lvchange -a y on it, however, gives me a resume ioctl failed message. Is there any hope for me to recover my data, or have I completely mucked it up?

    Read the article

  • Disk Activity Alert Windows SBS 2003 on Dell PowerEdge 830 with Raid

    - by Ron Whites
    Background: I have a Dell PowerEdge 830 Server running Windows SB Server 2003. It has 4gbs of RAM and a ATA CERC SATA 6CH controller with 3 160gb drives in a Raid 5 configuration. The Problem I am seeing Admin ---"Disk Activity Alert on Server" emails These often occur when disk backups, de-frag or high disk usage is going on. Generally the server isn't over stressed. The Disk Alert emails say in part ... The following disk has low idle time, which may cause slow response time when reading or writing files to the disk. Disk: 0 C: F: D: Review the Disk Transfers/sec and % Idle Time counters for the PhysicalDisk performance object. If the Disk Transfers/sec counter is consistently below 150 while the % Idle Time counter remains very low (close to 0), there may be a problem with the disk driver or hardware. The Questions I have: With what utility can I review the Disk Transfers/sec and Idle Time? It appears there is no utility for that on the server! I think I may need to download a very large (two DVD) Dell "OpenManage" utility to be able to monitor the raid system and see what is a problem is that true?

    Read the article