Search Results

Search found 14951 results on 599 pages for 'connect'.

Page 171/599 | < Previous Page | 167 168 169 170 171 172 173 174 175 176 177 178  | Next Page >

  • Windows 8 with LiveID login authenticates as Guest to remote SQl Server

    - by Tim Long
    I have a network where several users are using Office Accounting 2009 in multi-user client/server mode. OA is built on SQL Server. One PC acts as the 'server' and has the SQl Server instance, the others have only the application installed and no SQL instance, all of the apps connect remotely to the SQL instance on the 'server'. I'm using the term 'server' loosely here, it is just a normal workstation that happens to be designated as the server and runs the SQL instance. There is no NT domain, all user accounts are local accounts. The way that OA works in multi-user mode is that each user is required to have a local account with the same username and password on both the client and 'server' PCs. This has been working well, no along comes Windows 8. I use my 'Microsoft Account' aka LiveID to log into Windows 8. Office Accounting runs fine and attempts to connect to the database, but fails, 'you do not have permission to perform this operation'. In the SQL logs, I get this error: 2012-10-28 17:54:01.32 Logon Error: 18456, Severity: 14, State: 11. 2012-10-28 17:54:01.32 Logon Login failed for user 'SERVER\Guest'. Reason: Token-based server access validation failed with an infrastructure SERVER is the hostname of the server. So it seems to be authenticating as 'Guest'?? To verify this, I enabled the Guest account on the 'server' PC and then added Guest as an allowed user within Office Accounting (this simply creates the user in SQL and gives it an appropriate database role). Sure enough, My Windows 8 PC was then able to connect to the database when using Office Accounting. Clearly, having users authenticate as 'Guest' stinks from a security and auditing standpoint. So what I need are some ideas for how to work around this. I've tried switching the Windows 8 PC to a 'local account' and that works too, but requires giving up significant functionality on the Windows 8 PC. What I really need is a way to force the Windows 8 PC to use a specific set of credentials when connecting to the remote SQL instance. Office Accounting takes the logged in username, which is my LiveID and doesn't correspond to any Windows user name. Anyone solved this issue?

    Read the article

  • Internet Working, Browsing Not.

    - by jeffreypriebe
    I have a very odd problem that I can't resolve. I am connected to the internet, but my browsing doesn't work. I don't mean a web browser - I mean browsing. Firefox, Chrome, Curl all fail to successfully connect to an HTTP address. However existing connections, e.g. to mail in Outlook (Exchange Server and also IMAP server) continue to work. Also, the internet is on, I can confirm both from my machine (other ports / connections) as well as from any other computer connected to the same network. Additionally, it appears to be HTTP, not simple a port issue as HTTP over port 8443 (Tortoise SVN if you must know - running over HTTP not over SVN) also fails. I am using Windows Vista SP2 (build 6002). It seems to "creep up" in that after running the computer for a few hours it will fail. (No found way to systematically reproduce the problem.) Additionally, it seems to be more prone on days where the internet connection is flaky already (not sure why the internet is flaky, just is, lot's of failed browsing requests and have to retry/reload often). What I have tried (when the problem arises) - none have yielded any resolution: Resetting the network connection (dis-connect, re-connect) Disable/re-enable the network adapter Double-checked the ip settings Double-checked the HOSTS file. Note: DNS continues to work (both new and cached responses to DNS queries). (Thanks for the suggestion Daniel and antenore.) Checked the routing tables (ip4 only as ipv6 is beyond my understanding) resetting all involved hardware (routers and modems) Close and reopen browsers Looked for malware interference: Run HijackThis Looked for suspicious processes using SysInternals procexp. Looked for explorer hijacks, lsa provider interference, winsock provider interference using SysInternals Autoruns. Run a complete anti-virus scan. Reviewed the output of a netstat -onab to see if there were stuck ports open or unusual processes running somewhere The only thing that works is to do a full reboot. That works 100% of the time to restore browsing. What else can I try to nail down the problem?

    Read the article

  • Cisco VPN and .pcf file

    - by yael
    I have few of profiles .pcf files , and I used them in order to automate the vpmclient connection VIA CLI command I have WIN XP server for example vpmclient connect "customor_alpha" until now everything is ok but I have problem with the last of my profiles - area1.pcf the problem is when I type in CMD window the following ( to create VPN connection ) vpmclient connect "area1" after 2 second CISCO window will pop up and ask for password , ( username already defined in window ) please advice what could be the problem , why I get the "CISCO PVN window" ? or maybe I have some in correct syntax in my .pcf file , I checked the .pcf file again and again and I couldn't find the problem ? example of area1.pcf ( only example - not my real pcf ) [main] Description=connection to TechPubs server Host=10.10.99.30 AuthType=1 GroupName=docusers GroupPwd= enc_GroupPwd=158E47893BDCD398BF863675204775622C49<SNIPPED> EnableISPConnect=0 ISPConnectType=0 ISPConnect= ISPCommand= Username=alice SaveUserPassword=0 UserPassword= enc_UserPassword= NTDomain= EnableBackup=1 BackupServer=Engineering1, Engineering2, Engineering 3, Engineering4 EnableMSLogon=0 MSLogonType=0 EnableNat=1 EnableLocalLAN=0 TunnelingMode=0 TCPTunnelingPort=10000 CertStore=0 CertName= CertPath= CertSubjectName SendCertChain=0 VerifyCertDN=CN=”ID Cert”,OU*”Cisco”,ISSUER-CN!=”Entrust”,ISSURE-OU!*”wonderland” DHGroup=2 PeerTimeOut=90 ForceNetLogin=

    Read the article

  • Error # 1045 - Cannot Log in to MySQL server -> phpmyadmin

    - by SilverLight
    We have installed PHPMyAdmin on a windows machine running IIS 7.0. We are able to connect to MySQL using command-line, But we are not able to connect using PHPMyAdmin. The error displayed is: Error #1045 Cannot log in to the MySQL server. Can somebody please help? PHP Version 5.4.0 mysqlnd 5.0.10 - 20111026 - $Revision: 323634 $ phpMyAdmin-3.5.4-rc1-all-languages.7z EDIT : I followed the link below with no success, mean i changed that password but phpmyadmin still has that error... C.5.4.1.1. Resetting the Root Password: Windows Systems Thanks.

    Read the article

  • What causes critical glib errors (when coding using messaging menu)?

    - by fluteflute
    If I run the python code below (almost entirely from this useful blog post) then I get three identical nasty looking error messages in the terminal. What might be causing them? I note the number (5857 in the example below) changes slightly on each run. What does this number signify? Is it a memory location or something similar? (messaging-menu.py:5857): GLib-GIO-CRITICAL **: g_dbus_method_invocation_return_dbus_error: assertion `error_name != NULL && g_dbus_is_name (error_name)' failed (messaging-menu.py:5857): GLib-GIO-CRITICAL **: g_dbus_method_invocation_return_dbus_error: assertion `error_name != NULL && g_dbus_is_name (error_name)' failed (messaging-menu.py:5857): GLib-GIO-CRITICAL **: g_dbus_method_invocation_return_dbus_error: assertion `error_name != NULL && g_dbus_is_name (error_name)' failed I'm running this on Natty, I should probably find out if I get the same errors in 10.10 though... import gtk def show_window_function(x, y): print x print y # get the indicate module, which does all the work import indicate # Create a server item mm = indicate.indicate_server_ref_default() # If someone clicks your server item in the MM, fire the server-display signal mm.connect("server-display", show_window_function) # Set the type of messages that your item uses. It's not at all clear which types # you're allowed to use, here. mm.set_type("message.im") # You must specify a .desktop file: this is where the MM gets the name of your # app from. mm.set_desktop_file("/usr/share/applications/nautilus.desktop") # Show the item in the MM. mm.show() # Create a source item mm_source = indicate.Indicator() # Again, it's not clear which subtypes you are allowed to use here. mm_source.set_property("subtype", "im") # "Sender" is the text that appears in the source item in the MM mm_source.set_property("sender", "Unread") # If someone clicks this source item in the MM, fire the user-display signal mm_source.connect("user-display", show_window_function) # Light up the messaging menu so that people know something has changed mm_source.set_property("draw-attention", "true") # Set the count of messages in this source. mm_source.set_property("count", "15") # If you prefer, you can set the time of the last message from this source, # rather than the count. (You can't set both.) This means that instead of a # message count, the MM will show "2m" or similar for the time since this # message arrived. # mm_source.set_property_time("time", time.time()) mm_source.show() gtk.main()

    Read the article

  • No GUI boot; startx error, I suspect no filesystem corruption.

    - by Dharmaj Soni
    Till yesterday, my Ubuntu 9.10 was working fine. I had watched a movie using vlc. I had also charged my ipod using the laptop. Today, when I started it, I automatically booted into command line. There seems to be no filesystem corruption etc as I can view/open (text) files. Before the CLI appeared, the screen blinked with a cursor, then the white Ubuntu logo flashed, and then I got the CLI login prompt. After logging in, if I try startx, to start gnome, I get the following error after a few seconds: giving up xinit: No such file or directory (errno 2): unable to connect to X server xinit: No such process (errno 3): Server error* The same error comes up, even if I use sudo, or if I change my directory to '/' before using startx, and also when, from the grub, using the recovery mode option to load into CLI, and then trying startx. On trying command 'xinit', I get "Server error" Also, on trying GDM, I get 2 errors. I cannot connect to the internet in this state. Thanks for any help. I am using Dell Inspiron 1440, no special graphics card.

    Read the article

  • VPN only connects once and then fails

    - by Toby Allen
    I have a VPN connection setup to my office from home, it works great except for one thing. Once I connect and then disconnect the next time I go to connect to the vpn it hangs on verifying your username and password. No matter how many times I try. Once I restart my router it works again. My router is a belkin, the router on the other end is a Draytek. Any ideas? Is there a cache somewhere that needs to be reset, a setting?

    Read the article

  • Connecting both WAN and LAN ports to the same hub

    - by C. Lee
    For some reason I wish to connect the WAN port and the LAN port on a router to the same hub and make the hub is connected to both networks, the Internet and a private network. Below is a diagram of the network configuration I'd like to build. I tried this and it didn't work as expected. PC 1 has no problem, but PC 2 cannot connect to the Internet. When I ping 192.168.0.1 from PC 2, all packets are lost. It works well when PC 2 is connected directly to the router. What's the problem with the network configuration above?

    Read the article

  • apache proxypass to webmin

    - by Ricardo
    I have a problem with apache2 webmin redirect. My ProxyPass is: ProxyRequests Off ProxyPreserveHost On SSLProxyEngine On ProxyPass /admin/webmin/ https://localhost:10000/ ProxyHTMLURLMap https://localhost:10000 /admin/webmin <Location /admin/webmin/> ProxyHTMLExtended On SetOutputFilter proxy-html ProxyPassReverse https://localhost:10000/ ProxyPassReverse https://xxxxxxxxxxxxxxxxxxxx.amazonaws.com:10000/ Order allow,deny Allow from all </Location> When I connect using https://xxxxxxxxxxxxxxxxxxxx.amazonaws.com:10000/ there is no problem. But when I connect use https://xxxxxxxxxxxxxxxxxxxx.amazonaws.com/admin/webmin the page lost css and after login show me the error: The requested URL /session_login.cgi was not found on this server. I think is an error with my ProxyPass but I don´t know what is.

    Read the article

  • MWS2K8R2: Enabling Media Sharing using Streaming Media Services Role

    - by TheLizardKing
    So I have a Microsoft Windows Server 2008 R2 that stores a large collection of media (mostly mp3s) and I want to be able to deliver these files using a server/client setup with Windows Media Player being the client. I downloaded and installed Streaming Media Services Role. I even setup a publishing point with on-demand access. My issue is I can connect using WMP12 but it only connects as more of a stream and not a shared library. I can pause/play/skip as if it's a powerful radio station which is ok in my book but what I'd really like to do is allow me to control my music remotely, search and play for artists, maybe create playlists (not required but nice) and even connect it to an xbox. Is Streaming Media Services Role not what I should be using for this? Would installing WMP and sharing using that mechanism be a better option? Any Ideas?

    Read the article

  • RPi and Java Embedded GPIO: Using Java to read input

    - by hinkmond
    Now that we've learned about using Java code to control the output of the Raspberry Pi GPIO ports (by lighting up LEDs from a Java app on the RPi for now and noting in the future the same Java code can be used to drive industrial automation or medical equipment, etc.), let's move on to learn about reading input from the RPi GPIO using Java code. As before, we need to start out with the necessary hardware. For this exercise we will connect a Static Electricity Detector to the RPi GPIO port and read the value of that sensor using Java code. The circuit we'll use is from William J. Beaty and is described at this Web link. See: Static Electricity Detector He calls it an "Electric Charge" detector, which is a bit misleading. A Field Effect Transistor is subject to nearby electro-magnetic fields, such as a static charge on a nearby object, not really an electric charge. So, this sensor will detect static electricity (or ghosts if you are into paranormal activity ). Take a look at the circuit and in the next blog posts we'll step through how to connect it to the GPIO port of your RPi and then how to write Java code to access this fun sensor. Hinkmond

    Read the article

  • switch's mgmt-ip is not remotely reachable.

    - by RainDoctor
    Switch model: Netgear FSM7352PS mgmt-ip: 192.168.1.100/24 Vlan id: 1 (default) There are couple of hosts in this Vlan: 192.168.1.2 (esxi console), for instance. 192.168.1.1 is the firewall/router interface. I can ping 192.168.1.1 and 192.168.1.2 from other vlans, say, 172.31.0.0/24 I can ssh to 192.168.1.2 from 172.31.0.0/24 I can't ping 192.168.1.100 from 172.31.0.0/24 However, I can ping 192.168.1.100 from 192.168.1.2 or from my laptop connected to that vlan (192.168.1.11). I can connect to the web GUI from my laptop when I am in that Vlan. Can anyone shed some light on why I am not able to connect from other vlans?

    Read the article

  • Plugged in Not Charging.

    - by Eric Johnson
    Suggested steps to fix the nasty Windows power management issue of plugged in not charging. Option 1: Disconnect AC Shutdown Remove battery Connect AC Startup Under the Batteries category, right-click all of the Microsoft ACPI Compliant Control Method Battery listings, and select Uninstall (it’s ok if you only have 1). Shutdown Disconnect AC Insert battery Connect AC Startup Option 2: Turn off laptop. Unplug AC power. Remove battery. Replace AC power. Turn on laptop, allow OS to boot. Once logged in to the machine, perform a normal shut down. Unplug AC power. Replace battery. Replace AC power. Turn on laptop, allow OS to boot. The battery should once again be charging as normal Additional troubleshooting techniques: Check battery charging status in the BIOS Update BIOS Replace Battery (I did this and the new battery is not charging) See if the battery charging light works when the laptop is powered down. Supporting Links: http://jeffreypalermo.com/blog/plugged-in-not-charging-windows-7-solution/ http://social.technet.microsoft.com/Forums/en/itprovistahardware/thread/741398c6-a733-482c-a33c-2b61d9bc2984 http://www.youtube.com/watch?v=6Xf-ipP0wSY&feature=fvw

    Read the article

  • Router's ssid changes from infrastructure to ad-hoc

    - by waldo
    For a period of time the router's ssid is shown (on various computers) as a normal infrastructure network - computers connect fine and everything works however after a few minutes / hours all computers see the same ssid as an ad-hoc network (not infrastructure). At this point a computer that was already connected continues to work - a computer that isn't cannot connect. Rebooting the router temporarily restores the visibility of the correct infrastructure ssid. Is something interfering? Connecting computers: macbook (2009), iphone 3g, windows vista desktop, windows xp desktop. Details: - D-Link DSL-2740B router set to WPA2-PSK (Personal) - Enable Wireless : Yes - Wireless Network Name (SSID) : ###### - Country : Australia - Wireless Channel : 1 - 802.11 Mode : Mixed 802.11n, 802.11g and 802.11b - Channel Width : Auto 20/40 MHz - Transmission Rate : Best (automatic) - Hide Wireless Network : No - Group Key Update Interval : 0 (seconds)

    Read the article

  • Planning home network

    - by gakhov
    I'm planning to setup my home network from scratch and want to ask professional opinions or tips. My home is connected to Internet with a cable connection (100 Mb/s). The devices I would like to connect are VoIP phone (RJ-45), TV (WiFi/LAN), 3 laptops (WiFi), 2 smartphones (WiFi), an iPad (WiFi), a Kindle (WiFi), a network printer and, probably, a home media storage (WiFi/LAN). As you can see, the most load will be on WiFi connections (probably, even if TV supports WiFi it's better to connect it by LAN?). So, I need help to choose the best router (or combination of routers) to support stable connections for all these devices and minimize the total number of routers/adapters. I like how Cisco/Linksys devices were working for me in the past, so preferably (but not obligatorily) I want to setup network with their solutions. Any thoughts?

    Read the article

  • Resolve Wrong IP from Domain Name only on certain networks

    - by Godric Seer
    I host a personal website on an old desktop that is LAMP based. There are several strange things about this problem so I will break it down into steps. Since I have a dynamic IP, I use no-ip to make sure I have a working domain name at all times. I use the automatic update client, but logged in and checked and my no-ip domain has the proper IP tied to it. Here is a link to the homepage through the no-ip domain for reference. Also, I do a ping and a traceroute on the no-ip domain and get: [eckertzs@localhost ~]$ ping -c 1 endradil.noip.me PING endradil.noip.me (65.24.215.99) 56(84) bytes of data. 64 bytes from endradil.noip.me (65.24.215.99): icmp_seq=1 ttl=64 time=2.23 ms --- endradil.noip.me ping statistics --- 1 packets transmitted, 1 received, 0% packet loss, time 104ms rtt min/avg/max/mdev = 2.233/2.233/2.233/0.000 ms [eckertzs@localhost ~]$ traceroute endradil.noip.me traceroute to endradil.noip.me (65.24.215.99), 30 hops max, 60 byte packets 1 . (192.168.2.1) 1.755 ms 5.409 ms 5.380 ms 2 endradil.noip.me (65.24.215.99) 6.297 ms 9.543 ms 10.324 ms Using this domain, I can connect to my webserver without issue or interruption(the https is required to avoid a redirect serverside, but it works). I also have a domain I have bought on GoDaddy where I have a CNAME record forwarding the www subdomain to my no-ip domain. CNAME Record Host: www Points to: endradil.noip.me TTL: 1 hour For the past several weeks, I never had an issue using the GoDaddy domain to connect (ssh or https). As of the past few days, however, the GoDaddy domain has only worked intermittently, for a few minutes at a time and then will go down for hours at a time. I get server not found errors most of the time. Also, if I happen to be using the GoDaddy domain for an ssh connection, the connection will freeze. I have run online tests of the DNS and have seen that the website is visible by external servers and resolved to the correct IP. I also contacted GoDaddy support but they had no issues connecting to the website, and therefore did not see any issues. My personal computers (Windows desktop, linux laptop, android phone) all fail to connect when on my personal wifi. If I disconnect my phone from the wifi and use my AT&T wireless data, it can connect with both domains without issue. When I attempt to use Google webmaster tools to crawl the site using the GoDaddy domain, Google can not find the site. From my linux laptop, I have found some interesting results when I ping or traceroute the domain. The results from these: [eckertzs@localhost ~]$ ping -c 1 www.endradil.com PING www.endradil.com.Belkin (198.105.244.228) 56(84) bytes of data. --- www.endradil.com.Belkin ping statistics --- 1 packets transmitted, 0 received, 100% packet loss, time 10000ms [eckertzs@localhost ~]$ traceroute www.endradil.com traceroute to www.endradil.com (198.105.244.228), 30 hops max, 60 byte packets 1 . (192.168.2.1) 1.918 ms 2.806 ms 2.772 ms 2 cpe-65-24-208-1.insight.res.rr.com (65.24.208.1) 29.247 ms 29.654 ms 30.094 ms 3 cpe-69-23-24-117.new.res.rr.com (69.23.24.117) 15.597 ms 23.218 ms 23.581 ms 4 agg24.clmcohib01r.midwest.rr.com (65.29.1.52) 30.581 ms 30.556 ms 31.192 ms 5 be27.clevohek01r.midwest.rr.com (65.29.1.38) 30.580 ms 31.062 ms 31.038 ms 6 bu-ether25.atlngamq47w-bcr01.tbone.rr.com (107.14.19.38) 37.863 ms 68.844 ms 43.773 ms 7 107.14.17.178 (107.14.17.178) 51.866 ms 51.019 ms 50.989 ms 8 ae0.pr1.dca10.tbone.rr.com (107.14.17.200) 48.467 ms ae-4-0.a0.lax91.tbone.rr.com (66.109.1.113) 49.912 ms * 9 v413.core1.ash1.he.net (209.51.175.33) 60.270 ms 50.842 ms 50.819 ms 10 100ge5-1.core1.nyc4.he.net (184.105.223.166) 55.597 ms 56.045 ms 56.020 ms 11 xerocole-inc.10gigabitethernet12-4.core1.nyc4.he.net (216.66.41.242) 56.001 ms 55.969 ms 55.992 ms 12 * * * both show the incorrect IP. Also, the traceroute timesout on hops 12 through 255 (output truncated above). The traceroute using site24x7 works and shows reasonable results when run from their california server. From another linux box on a different network but in the same city as me (10 miles away), I still get timeout for traceroute, however the IP resolves correctly for the domain. From this I believe that the DNS result is incorrectly cached in either my router/modem or perhaps even at my ISP level. My question is, first, how do I find out exactly what is wrong, and second, how do I resolve it.

    Read the article

  • Problem connecting to SSH in office network

    - by Jeune
    I have trouble connecting via SSH to a server whenever I am in the office. I get as far as being prompted for my password and then after that there's a long wait which always ends in a Write failed: Broken pipe This is only for connecting via SSH. I use svn to commit files to a repository hosted on the same server and there are no hitches. Furthermore, this only happens in our office. When I go the university or whenever I am at home or at the coffee shop I am able to connect seamlessly. There are no firewalls in our office. It's just a basic wireless router connected to a modem setup. It's the same setup I have at home and I guess the same setup in the coffee shop. What are the causes for a broken pipe and why does this phenomenon only happen when I try connect via SSH and not when I work with svn on the same server? Updated: Some debug logs after authentication: debug3: packet_send2: adding 48 (len 64 padlen 16 extra_pad 64) debug2: we sent a password packet, wait for reply debug1: Authentication succeeded (password). debug1: channel 0: new [client-session] debug3: ssh_session2_open: channel_new: 0 debug2: channel 0: send open debug1: Entering interactive session. debug2: callback start debug2: client_session2_setup: id 0 debug2: channel 0: request pty-req confirm 1 debug1: Sending environment. debug3: Ignored env ORBIT_SOCKETDIR debug3: Ignored env SSH_AGENT_PID debug3: Ignored env TERM debug3: Ignored env SHELL debug3: Ignored env XDG_SESSION_COOKIE debug3: Ignored env WINDOWID debug3: Ignored env GNOME_KEYRING_CONTROL debug3: Ignored env GTK_MODULES debug3: Ignored env USER debug3: Ignored env LS_COLORS debug3: Ignored env LIBGL_DRIVERS_PATH debug3: Ignored env SSH_AUTH_SOCK debug3: Ignored env DEFAULTS_PATH debug3: Ignored env SESSION_MANAGER debug3: Ignored env USERNAME debug3: Ignored env XDG_CONFIG_DIRS debug3: Ignored env DESKTOP_SESSION debug3: Ignored env LIBGL_ALWAYS_INDIRECT debug3: Ignored env PATH debug3: Ignored env PWD debug3: Ignored env GDM_KEYBOARD_LAYOUT debug1: Sending env LANG = en_PH.utf8 debug2: channel 0: request env confirm 0 debug3: Ignored env GNOME_KEYRING_PID debug3: Ignored env MANDATORY_PATH debug3: Ignored env GDM_LANG debug3: Ignored env GDMSESSION debug3: Ignored env SHLVL debug3: Ignored env HOME debug3: Ignored env GNOME_DESKTOP_SESSION_ID debug3: Ignored env LOGNAME debug3: Ignored env XDG_DATA_DIRS debug3: Ignored env DBUS_SESSION_BUS_ADDRESS debug3: Ignored env LESSOPEN debug3: Ignored env WINDOWPATH debug3: Ignored env DISPLAY debug3: Ignored env LESSCLOSE debug3: Ignored env XAUTHORITY debug3: Ignored env COLORTERM debug3: Ignored env OLDPWD debug3: Ignored env _ debug2: channel 0: request shell confirm 1 debug2: fd 3 setting TCP_NODELAY debug2: callback done debug2: channel 0: open confirm rwindow 0 rmax 32768 UPDATE 2011-14-07: I am able to connect to the server via SSH now. I didn't do anything but that's because there is no one in the office but me! Having said that, is it possible that it has something to do with the number of sessions an SSH server can handle? UPDATE 2011-14-07: I try to login via SSH through Putty on another machine running windows together with my current SSH session in Ubuntu and now it seems my SSH session in Ubuntu has been dropped. I can't type into the terminal. Is Putty the culprit now?

    Read the article

  • I can't do a Remote Assistance session to a Windows XP box from Windows 7.

    - by superkinhluan
    My Mom's computer is running Windows XP, and my desktop running Windows 7. She's having some technical issue, so I want to do a Remote Assistance session to her machine. However, no matter what I've tried, the Remote Assistance program doesn't connect successfully. I've verified that the Windows Firewall (on both my and her machines) is configured properly to allow Remote Assistance program to go through. What's interesting is that I have the same problem when I try to do Remote Assistance from my desktop to my laptop, which is also running Windows XP. However, when I try to connect to my girlfriend's machine, which is runninng Windows 7 this time, the connection is successful. So in the end, I guess there must be some incompability between Windows 7 and Windows XP. Does anyone experience the same issue? How did you resolve it?

    Read the article

  • Common request: export #Tabular model and data to #PowerPivot

    - by Marco Russo (SQLBI)
    I received this request in many courses, messages and also forum discussions: having an Analysis Services Tabular model, it would be nice being able to extract a correspondent PowerPivot data model. In order of priority, here are the specific feature people (including me) would like to see: Create an empty PowerPivot workbook with the same data model of a Tabular model Change the connections of the tables in the PowerPivot workbook extracting data from the Tabular data model Every table should have an EVALUATE ‘TableName’ query in DAX Apply a filter to data extracted from every table For example, you might want to extract all data for a single country or year or customer group Using the same technique of applying filter used for role based security would be nice Expose an API to automate the process of creating a PowerPivot workbook Use case: prepare one workbook for every employee containing only its data, that he can use offline Common request for salespeople who want a mini-BI tool to use in front of the customer/lead/supplier, regardless of a connection available This feature would increase the adoption of PowerPivot and Tabular (and, therefore, Business Intelligence licenses instead of Standard), and would probably raise the sales of Office 2013 / Office 365 driven by ISV, who are the companies who requests this feature more. If Microsoft would do this, it would be acceptable it only works on Office 2013. But if a third-party will do that, it will make sense (for their revenues) to cover both Excel 2010 and Excel 2013. Another important reason for this feature is that the “Offline cube” feature that you have in Excel is not available when your PivotTable is connected to a Tabular model, but it can only be used when you connect to Analysis Services Multidimensional. If you think this is an important features, you can vote this Connect item.

    Read the article

  • Remote desktop connection issues in windows server 2003

    - by rboorgapally
    Hi all, We are running windows server 2003 at our work place. I have enabled the remote desktop connections. I have also added all the users who connect to the server(three to four people) to the RDC group of users. Many of these users are also having Administrator access. The problem we are facing is that the connection is suddenly lost when we are working on something. Also, at times the system restarts by itself. Is this issue related to the limit on the number of users able to connect to the system? If so, why does the system accept new connections and/or terminate the existing connections? Has this anything to do with the users having administrator access so that all have equal prority and that is why existing connections are stalled? Also, please differentiate between console remote desktop and non console remote desktop.

    Read the article

  • Cascading switches: uplink to uplink?

    - by wuckachucka
    I'm a bit confused as to why I haven't seen any references online to using Switch A's uplink port (1Gbps, 24-port 10/100) to connect to Switch B's uplink port: everything I've seen -- including documentation, forums, articles, etc. -- has Switch A's uplink port going to one of Switch B's 10/100 access ports. As I understand it, the Uplink port (besides greater speed normally) is no different than another port except that it's "internally crossed-over" so that you can use a straight cable with it. I've also seen documentation on using the uplink port to connect a switch to a gateway router, or even a server, as it provides greater bandwidth than the access ports, but yet not sure why nobody seems to be cross-uplinking, even when there's 2 uplink ports available on some higher-end switches. Switch in question is Linksys SRW224P (x2). Am I missing something?

    Read the article

  • Windows/Samba connection error

    - by Gomibushi
    I have a Linux fileserver serving up /home for linux and windows users. I was able to connect from my windows client, but not from a DC. Then suddenly I could connect from the DC too. The linux servers run Centrify clients, and as such are part of the domain. All on same subnet. This is what the the log.smbd says, repeatedly: [2010/02/11 11:25:57, 0] lib/util_sock.c:read_data(534) read_data: read failure for 4 bytes to client 192.168.200.3. Error = Connection reset by peer On Windows it appeared as an "unknown error". EDIT: the error code is "0x80004005". We are developing a system depended on the samba share, and are worried this will appear again. It would be nice to pin point the root of this. Any ideas what this might be? Places to look?

    Read the article

  • Activesync/OWA Desktop Client

    - by prestomation
    At my company we have Exchange 2k3 with OWA being public, serving up Activesync and webmail. There is no pop3 or imap support from our admins. Outlook 2k3's RPC over HTTP is also disabled Is there a desktop client that can connect to Activesync or OWA? If my ipod touch can connect to activesync, why can't my pc? I'd preferably like a linux daemon that could simply forward emails to my gmail address, but I guess I'll take what I can get. Thanks EDIT: In case it was not clear, our Exchange server is hidden completely behind a firewall, and a second exchange server has only activesync and https ports opened to the world.

    Read the article

  • Cisco ASA SSL VPN options?

    - by JonH
    Disclaimer: I am not a network admin so I may be wrong here but I thought asking here would help. I'm a developer mainly on the .net framework as well as helping get a mobile intranet app working. Because this app is only allowed to be used on our network I can easily run this app on our wireless network connection within our building. All is fine and dandy but we'd also like to be able to run this mobile app at say a customer plant using VPN software. I thought surely this could be easy as we exclusively use Samsung s4 phones so I thought I'd download Cisco's Samsung any connect software to allow us to VPN...its right on the play store. Sure enough it doesn't work. I mention it to our network admin who says not possible since we have old technology that doesn't support SSL. He mentions we'd have to upgrade all of our hardware, the firewall, etc. to get this to work. We really need VPN on our phones not only for this app but other internal apps, etc. He did mention the following: We can’t upgrade the software on our ASA, because we don’t have enough memory for the new version.  (the asa is very old).  We can’t add more memory, so we would have to get a new firewall, which I have been told I cannot do. In addition he also mentioned: The Samsung AnyConnect client uses SSL to connect.  With the current (old) version of software that our firewall is running, the SSL connections are unreliable.  We need different hardware in order to upgrade our firewall, which we are unable to attain at this time.  This is the same reason that Windows 8 clients are not able to connect. I am curious hence me asking. vpns seem to be fairly simple to setup. What other options do I have aside from making this a public site or web service that consumes this data over the internet as this is a complete no no. What can we do to make this work without that much effort or cost.

    Read the article

< Previous Page | 167 168 169 170 171 172 173 174 175 176 177 178  | Next Page >