Search Results

Search found 5716 results on 229 pages for 'dual channel'.

Page 187/229 | < Previous Page | 183 184 185 186 187 188 189 190 191 192 193 194  | Next Page >

  • Using multiple computers effectively

    - by Benjamin Oakes
    I have some extra (old) Macs and PCs around the house and a MacBook that's sometimes overworked. I'm looking for tips on using multiple computers effectively. Basically, I'd like to add to the following list. Here's what I'm using so far: Teleport: lets you use a single mouse and keyboard to control several Macs, like Synergy Built-in file sharing: lets me run programs on another Mac, but only maintain one copy of the data Bazaar: distributed version control Mail.app, Thunderbird, etc.: IMAP for my mail accounts TuneConnect: control iTunes on another Mac with a nice interface, using the library on my MacBook (if I choose it by pressing option at startup) over file sharing OmniFocus: syncs across computers pretty seamlessly Web browsing across computers VNC/Remote Desktop Running X-windows programs using ssh -Y hostname for headless operation (but they die when I sleep the connecting computer -- something like GNU screen would be ideal) Plain-old ssh with GNU screen Really, a better idea of what I do might be necessary. Generally though, I'd like to distribute tasks across more than one computer when possible, but not have much overhead in doing so. The perfect solution? An Xgrid-like program that pushes processing across multiple computers automatically and seamlessly (although that seems unlikely). Here's what I have, in case it makes a difference: MacBook (Dual 2.16 GHz, OS X 10.6.3) eMac (1.25 GHz, OS X 10.4.11, soon to be 10.5) Dell Dimension (800 MHz, some version of Ubuntu) -- no dedicated monitor PowerMac G3 (400 MHz, OS X 10.4.11) -- no dedicated monitor iMac G3 DV (400 MHz, OS X 10.4.11) -- currently in the kitchen for recipes, email, web browsing, music, movies (DVDs), etc. (Total, they cost me around $650, mostly for the MacBook. Freecycle is wonderful, just in case you haven't heard of it.) I'm really only using the MacBook and eMac at this point, but I'd like to push more onto it and possibly the PowerMac and Dell.

    Read the article

  • Increasing MSSQL/Sage performance with SSD? (Dell PE T410)

    - by Anthony
    I have a client wanting better performance of their Sage (Accpac & CRM) server (v5.5, soon to be v7). It's running on 1 of 2 Hyper-V VMs (Svr2008) on a Dell PE T410 server with 24GB of RAM (1333MHz) & dual quad-core, and both VMs (only their C: drives) are on a single RAID5 array. All clients connect via 1Gb ethernet. The 2nd VM is SBS2008 with 9GB RAM (& all SBS dbs & company data are on a separate RAID5 array), & 3GB RAM for the Svr2008 hypervisor. I've given the Sage/MSSQL VM all the RAM I can (12GB) & SQL RAM caching (~8GB, never exceeds ~7.5GB, eg. entire db can now be cached in RAM) and that's helped significantly. Upgrading the Hypervisor to Svr2012 is an obvious step, but probably not a dramatic improvement? What about an SSD for this Sage/SQL VM (VM = 100GB, <10GB for the actual live DB) ? Can SSDs be put into the SAS hot-swap bays? Or will I have to use the mobo SATA(3Gbps?) ports, or PCI-E SSD card? Should SSDs be RAIDed for this situation? Or is SSD's higher reliability offsetting the need for RAID1/5/10? (I have nightly full disk backups) New territory for me, would appreciate some feedback. Thanks, Anthony.

    Read the article

  • How to make 7-Zip faster

    - by Matt
    I normally use WinRAR over 7-Zip simply because it's faster and only a little less efficient with compression. I did a few tests on different filetypes and sizes comparing the 7-Zip and WinRAR default settings on their normal compression and their best compression, and in a lot of cases WinRAR was 50% faster and in some it was actually 100% faster. But, I do like FOSS more. So here are my questions: Is there a way to make 7-Zip speed up? I'd like it to at least be on par with WinRAR's speed Is there a way to make recovery segments in 7-Zip like you can in WinRAR? I didn't see any, but I guess it could be a command line thing. I tested WinRAR and 7-Zip using the latest stable version of each (4-dot-something with 7-Zip). Is the 9.x beta release noticeably faster at compression? I'm talking about faster at a comparable setting in WinRAR, not just lowering to bare minimum compression. If it matters, I use a quad core Intel i7 720 (1.6 GHz)/(2.8 GHz) with 4 GB DDR3 RAM, and the 64-bit version of 7-Zip, and dual-boot Debian x64 5.0.4 and Windows 7 Home.

    Read the article

  • Display stretches 4:3 ratios; Adds scrolling to other ratios

    - by Matt
    I have a dual monitor setup. Normally, they both display at 1680x1050. They have been setup this way for about a year. I'm using Windows XP Professional 2003 x64 SP2. Today, out of nowhere, one of the monitors kicked back to a lower resolution. I was not playing with any configuration at the time.. in fact all I had done was close a window (maybe a browser). But the thing is that the resolution is still preserved partially by the fact that the screen will scroll when you move the mouse. So it's like looking through a 1024x768 window into a 1680x1050 world. The monitor itself does not appear to be damaged, because I also have it connected to my netbook (via KVM) and higher resolutions work fine. I tried uninstalling/reinstalling the drivers to no avail. System restore doesn't help either. I'm unsure of the exact ATI card I'm using.. Device Manager lists it as "Radeon X300/X550/X1050". There is no Catalyst Control Center software installed. I tried to install it, but there doesn't seem to be a way to install it by itself ... it forces you to install another driver, which breaks both of my displays, forcing me to go into safe mode and run system restore again. Any ideas? Thanks EDIT: After playing around more, I discovered that the "scrolling" behavior is only present for aspect ratios that are not 4:3. For 4:3 ratios, it just stretches out to fit the wide screen. My monitor's native ratio is 16:9 .. what could be causing it to think it needs to scroll?

    Read the article

  • Sort order in Windows Explorer

    - by Haim H.
    The behaviour described below occurs on Windows-7 systems and on Windows XP. We operate in a dual-language environment - English and Hebrew. When in Windows Explorer we sort files by name, the order in which they are listed is not what we would expect. Here is a list of file names as sorted by Windows Explorer (all of the files have a .pdf suffix): 1G110033H-PP 19C050G-PP-ORB 19C050H-PPRM 19C100H-PPRM 19C-MBPS-PP 19C-MBPS-PP-1 29AAC050-PP 29AAC100-PP 29AAC100-PPUL 29B004064-PP 101AC050-PP 101AC100-PP 101B100-PPE 1091003G-PPFSUL 10108033G-PPSA 10125033H-PPM It looks to me that first the items are sorted according to the position of the first alphabetic character in the name, and then, within those groups, they are sorted in "normal" alpha-numeric order. That is, all the files with an alpha character in the first position are on top of the list, followed by those with the first alpha character in the second position, followed by those with the first alpha character in the third position, and so on. An alternate way of looking at this is that, in a file name composed of numbers and letters, the sort treats the first group of numbers in the name as the major sort node, with the rest of the name being the secondary sort node. Now that I understand the sequencing logic, it's not a big problem, but I was wondering why this happens?

    Read the article

  • ProCurve network expansion

    - by Blue Warrior NFB
    I've hit a bit of a wall with our network scale-out. As it stands right now: We have five ProCurve 2910al switches connected as above, but with 10GbE connections (two CX4, two fiber). This fully populates the central switch above, there will be no more 10GbE Ethernet connections from that device. This group of switches is not stacked (no stack directive). Sometime in the next two or three months I'll need to add a sixth, and I'm not sure how deep of a hole I'm in. Ideally I'd replace the core switch with something more capable and has more 10GbE ports. However, that's a major outage and that requires special scheduling. The two edge switches connected via fiber have dual-port 10GbE cards in them, so I could physically put another switch on the far end of one of those. I don't know how much of a good or bad idea that would be though. Is that too many segments between end-points? Some config-excerpts: Running configuration: ; J9147A Configuration Editor; Created on release #W.14.49 hostname "REDACTED-SW01" time timezone 120 module 1 type J9147A module 2 type J9008A module 3 type J9149A no stack trunk B1 Trk3 Trunk trunk B2 Trk4 Trunk trunk A1 Trk11 Trunk trunk A2 Trk12 Trunk vlan 15 name "VM-MGMT" untagged Trk2,Trk5,Trk7 ip helper-address 10.1.10.4 ip address 10.1.11.1 255.255.255.0 tagged 37-40,Trk3-Trk4,Trk11-Trk12 jumbo ip proxy-arp exit

    Read the article

  • Cannot connect on TFS 2012 server through SSL with invalid certificate

    - by DaveWut
    I saw the problem on some forums and even here, but not as specific as mine. So here's the thing, So I've configured a TFS 2012 server, on one of my personnel server at home, and now, I'm trying to make it available through the internet, with the help of apache2 on a different UNIX based, physical server. The thing is working perfectly, I don't have any problem accessing the address https://tfs.something.com/tfs through my browser. The address can be pinged and I do have access to the TFS control panel through it. How does it work? Well, with apache2 you can set a virtual host and set up the ProxyPass and ProxyPassReserver setting, so the traffic can externally comes from a secure SSL connection, through a specified domain or sub-domain, but it can be locally redirect on a clear http session on a different port. This is my current setup. As I already said, I can access the web interface, but when I'm trying to connect with Visual Studio 2012, it can't be done. Here's the error I receive: http://i.imgur.com/TLQIn.png The technical information tells me: The underlying connection was closed: Could not establish trust relationship for the SSL/TLS secure channel. My SSL certificate is invalid and was automatically generated on my UNIX server. Even if I try to add it in the Trusted Root Certification Authorities either on my TFS server or on my local workstation, it doesn't work. I still receive the same error. Is there's a way to completely ignore certificate validation? If not, what's have I done? I mean, I've added the certificate in the trusted root certificates, it should works as mentioned on some forums... If you need more information, please ask me, I'll be pleased to provide you more. Dave

    Read the article

  • Why would I be getting IXFR and AXFR transfer denied on my DNS server?

    - by danielj
    From everything I've researched and tried, it appears that my named.conf is configured correctly, including the allow-transfer section. Here is a sample of the errors. It is only happening with a couple of my secondary servers, but it is happening for every zone for those servers that are failing. One of the servers is attempting IXFR, the other AXFR. The result is the same: 18-Mar-2011 14:27:51.372 security: error: client 84.234.24.90#59208: zone transfer 'juansgaranton.com/IXFR/IN' denied 18-Mar-2011 14:32:18.015 security: error: client 174.37.196.55#50783: zone transfer 'cheshirecat.net/AXFR/IN' denied Here is the relevant part of named.conf. options { directory "/etc/bind"; pid-file "/var/run/named/named.pid"; files 4096; allow-transfer { 140.186.190.103; 84.234.24.90; 207.246.95.34; 203.20.52.5; 140.186.190.103; 127.0.0.1; 174.37.196.55; }; }; logging { channel "bind" { file "/var/log/bind.log" versions 3; print-time yes; print-severity yes; print-category yes; severity info; }; category lame-servers { null; }; category "default" { "bind"; }; };

    Read the article

  • I keep losing wireless connection

    - by posfan12
    I have a WRT54GL v1.1 wireless router and a WUSB54G v4 wireless adapter, both made by Linksys. The router is in the living room by the TV and the my computer is in the bedroom. My ISP is Brighthouse. Operating System Microsoft Windows 7 Home Premium 64-bit SP1 CPU Intel Core 2 Duo E6600 @ 2.40GHz 36 °C Conroe 65nm Technology RAM 3.00GB Single-Channel DDR2 @ 333MHz (5-4-4-14) Motherboard eMachines EMCP73VT-PM (CPU 1) 26 °C Graphics ASUS VS247 (1920x1080@60Hz) 767MB GeForce GTX 460 (nVidia) 43 °C Hard Drives 466GB Seagate ST350041 8AS SCSI Disk Device (SATA) 35 °C Optical Drives HL-DT-ST DVDRAM GH41N SCSI CdRom Device Audio High Definition Audio Device The problem is that my Internet connection will work fine for 15 minutes or so. Then the data will just stop flowing. Windows says I am still connected, and the systray icon still shows five bars. But Comodo Firewall will stop showing up and down traffic, and another of my systray applications complains about a lack of connection. What I usually do is either disconnect from the network manually, or unplug and re-plug the USB adapter. At which point the connection will work properly for another 15 minutes. I've tried unplugging my router for 30 seconds and letting it reboot. I've also tried looking for a newer driver for my adapter but I seem to have the latest version 3.1.3.0. This is a recent problem starting about a week ago. For the previous several months things were working just fine. I haven't made any changes to my system that I am aware of. The only thing I did was open my case to blow the dust out of it, then put everything back together. How do I fix this issue?

    Read the article

  • Linux NIC Bonding Issue (CentOS 4 / RHEL 3)

    - by jinanwow
    I am having an issue with bonding NICs on CentOS 4. It appears the bonding driver does work, but it is stuck in round-robin mode and I am trying to get to active-backup. The current config is: ifcfg-bond0 DEVICE=bond0 IPADDR=192.168.204.18 NETMASK=255.255.255.0 ONBOOT=yes BOOTPROTO=none USERCTL=no TYPE=Bonding BONDING_OPTS="mode=1 miimon=100" ifcfg-eth1 DEVICE=eth1 BOOTPROTO=none ONBOOT=yes TYPE=Ethernet MASTER=bond0 SLAVE=yes ifcfg-eth3 DEVICE=eth3 ONBOOT=yes BOOTPROTO=none TYPE=Ethernet MASTER=bond0 SLAVE=yes cat /proc/net/bonding/bond0 Ethernet Channel Bonding Driver: v2.6.3-rh (June 8, 2005) Bonding Mode: load balancing (round-robin) MII Status: up MII Polling Interval (ms): 0 Up Delay (ms): 0 Down Delay (ms): 0 Slave Interface: eth1 MII Status: up Link Failure Count: 0 Permanent HW addr: 00:17:a4:8f:94:b1 Slave Interface: eth3 MII Status: up Link Failure Count: 0 Permanent HW addr: 00:1b:21:56:b8:69 cat /etc/modprobe.conf alias eth0 tg3 alias eth1 tg3 alias eth3 e1000 alias eth2 e1000 alias bond0 bonding options bond0 mode=1 miimon=100 I have tried moving the bonding information out of the ifcfg-bond0 into the modprobe configuration file. It seems that it is stuck in RR and I am trying to get it into the Active-backup (mode 1) state. Any ideas what would be causing this issue?

    Read the article

  • How to eliminate overscan on Ubuntu HTPC

    - by Norman Ramsey
    I'm using an Ubuntu box with Nvidia graphics card as an HTPC. My HDTV is a Sony Bravia KDS-R50XBR1; this is a rear-projection unit with many inputs. I am using the HDMI input. I'm using the proprietary Nvidia drivers and they recognize the 1080x1920 resolution just fine. The display is a little fuzzy but at 50 inches it's perfect for movies. My problem is that the TV has three overscan settings, and none of them reduces overscan to zero. When I was using dual-screen this was fine, but I'm moving to where the TV is my only screen, and the Gnome panels are not visible because of the overscan. I'd like to figure out how to eliminate the overscan, without trying to scale my 1080p content down to 920p or something ridiculous like that. Ideally there would be some scurvy trick, perhaps involving the TV service menu, to get rid of the overscan on the TV side. Or I could move the Gnome panels, but I still would be missing the edges of my movies. Suggestions most welcome.

    Read the article

  • Controller Error: Do I need to worry?

    - by Kryten
    Hi, I have a HP Pavillion dv5224ea Laptop with Windows 7 on it. Recently I discovered a Error in Event Viewer: The driver detected a controller error on \Device\Ide\IdePort1. (more details): - System - Provider [ Name] atapi - EventID 11 [ Qualifiers] 49156 Level 2 Task 0 Keywords 0x80000000000000 - TimeCreated [ SystemTime] 2010-03-07T12:43:07.090197600Z EventRecordID 30198 Channel System Computer Alistair-Win7 Security - EventData \Device\Ide\IdePort1 0000100001000000000000000B0004C002000000850100C00000000000000000000000000000000000000000000000000000000004100000 -------------------------------------------------------------------------------- Binary data: In Words 0000: 00100000 00000001 00000000 C004000B 0008: 00000002 C0000185 00000000 00000000 0010: 00000000 00000000 00000000 00000000 0018: 00000000 00001004 In Bytes 0000: 00 00 10 00 01 00 00 00 ........ 0008: 00 00 00 00 0B 00 04 C0 .......À 0010: 02 00 00 00 85 01 00 C0 ......À 0018: 00 00 00 00 00 00 00 00 ........ 0020: 00 00 00 00 00 00 00 00 ........ 0028: 00 00 00 00 00 00 00 00 ........ 0030: 00 00 00 00 04 10 00 00 ........ Event Viewer is recording A LOT of these errors (sometimes 13, one after the other!). Do I need to worry? What does this error mean? What device could "\Device\Ide\IdePort1" be? What is a ATAPI Error? Do I need to re-install Windows? I generally find the occurs when I try to backup my machine (using Windows Backup) or when using a program that uses Volume Shadow Copy. I have run "sfc", no problems. There are no Device Errors in Device Manager. I have also run "vssadmin list writers", no problems. Whats going on??? Would it be a good idea to re-install Windows 7?

    Read the article

  • Issues with sustained traffic with PFSense

    - by Farseeker
    Last week we had to replace our PFSense firewall because it had a catastrophic hardware failure. All but one of the NICs were taken out of the old server and put into the new one. The one NIC that was not moved was the LAN NIC as this is on-board. The other NICs are all WAN connections and the must all be present (i.e. I can't disable one just for the sake of testing) After re-installing PFSense and restoring our backup of the configuration, everything came back online just fine, however on the new hardware any download that takes longer than about 10 seconds just times out in the middle. Example 1: Downloading from Microsoft.com goes at about 900k/sec and times out after about 10 seconds (thus, just under 10Mb of content) Example 2: Downloading from cnet.com goes at about 300k/sec and times out after about 10 seconds (thus, about 3Mb of content). By times out, I mean that the download just stops, and you have to pause/resume to get the next part done, repeat and rinse until the download is complete. However it's not consistant, sometimes it's 10 seconds, sometimes it's 4 seconds, and it sometimes you can't even load a heavy HTML page because the page never finishes. I assume this is most likely because PFSense does not like the onboard NIC, as this is the primary difference between the two servers. It's recognised as NFE0, and there's no room in the server for any more NICs and I don't have any dual-port NICs handy to experiment with a different LAN connection. I've never had to troubleshoot this sort of issue before. Can anyone give me some pointers about where to start? Linux is not my forte so please be kind!

    Read the article

  • How to connect through a proxy using Remote Desktop?

    - by scottmarlowe
    So I've got a home server running Windows Server 2003. I use a dual network card setup and Routing and Remote Access to link the internal, private network to the external connection. The external connection hooks directly to my cable modem (so no routers or other devices sitting between). The problem I'm having is that I can't connect remotely from a location outside the house (so connecting to the server's external connection) to the server using either Remote Desktop or VNC. I have enabled both ports in Routing and Remote Access's firewall to allow access, and I have enabled Remote Desktop in Windows Server 2003. The odd thing is that I can access my home server's SVN repository and I can even ping the server's IP. I am using the IP to attempt to connect, though I use a dyndns.com provided name to connect to my SVN repository, so it shouldn't make a difference (I know the IP is getting resolved correctly). Any ideas on where to start diagnosing this one? I haven't seen anything in my server's event log. If any other info is needed, let me know. Thanks. UPDATE: One last piece of information: We use a proxy server at work, which I'm nearly 100% sure is the culprit. I have a workaround--if I connect to our VPN (even though I'm already inside the building) I am able to connect to my home server. This is with VNC. However, is there a way to connect through a proxy using Remote Desktop? ONE MORE UPDATE: Indeed, it was the http proxy I'm sitting behind at work that was causing the issue. An acceptable workaround is to use my VPN connection to bypass the proxy, and I'm in!

    Read the article

  • Segmentation fault on login to mysql

    - by numberwhun
    Hello everyone! I recently did a fresh install of Ubuntu on my laptop (HP dv7, AMD Dual Core with 4 gigs RAM). I am working on installing my development environment and tools and one of the first things I was working on is getting MySQL installed. The following was my configure statement with options: ./configure --prefix=/usr/local/mysql --with-big-tables --with-unix-socket-path=/usr/local/mysql/tmp/mysql.sock --with-named-curses-libs=/lib/libncurses.so.5.7 After I did the make;make install, I did the post configuration such as setting the root password and installing the mysqld daemon in its rightful place. My issue is when I try to log in to mysql to start using it, the following shows what happens: $ mysql -u root -p Enter password: Welcome to the MySQL monitor. Commands end with ; or \g. Your MySQL connection id is 1 Server version: 5.1.42 Source distribution Segmentation fault I have searched Google extensively, I have searched through the mysql bugs database and I have yet to find anything that matches my issue. Here is the contents of my my.cnf file, in case you want to see it: $ cat /etc/my.cnf [mysqld] basedir=/usr/local/mysql datadir=/usr/local/mysql socket=/usr/local/mysql/tmp/mysql.sock [mysql.server] user=mysql #basedir=/var/lib [client] socket=/usr/local/mysql/tmp/mysql.sock [mysqld_safe] err-log=/usr/local/mysql/logs/mysqld.log pid-file=/var/run/mysqld/mysqld.pid I am really hoping that someone here can tell me what has gone wrong with my installation as I would really love to know. I welcome and look forward to all responses. Thank you in advance! Best regards, Jeff

    Read the article

  • help with xorg.conf: xrandr on one of two widescreen monitors; rhel5, kde, ATI Radeon X1300

    - by user35997
    Can anyone help with me configure my dual-screen monitors for rotation? I have xrandr 1.1. Have tried various approaches, nothing takes. I can't even get the xrandr options to show up in KDE's Display control panel. Thanks1 My lspci output: 03:00.0 VGA compatible controller: ATI Technologies Inc RV516 [Radeon X1300/X1550 Series] My current xorg.conf (works, minus screen rotation): # Xorg configuration created by system-config-display Section "ServerLayout" Identifier "Multihead layout" Screen 0 "aticonfig-Screen[0]" 0 0 InputDevice "Keyboard0" "CoreKeyboard" Option "Xinerama" "off" Option "Clone" "on" EndSection Section "Files" EndSection Section "Module" EndSection Section "InputDevice" Identifier "Keyboard0" Driver "kbd" Option "XkbModel" "pc105" Option "XkbLayout" "us" EndSection Section "Monitor" ### Comment all HorizSync and VertSync values to use DDC: Identifier "Monitor1" VendorName "Monitor Vendor" ModelName "Dell 2407WFP (Digital)" HorizSync 30.0 - 83.0 VertRefresh 56.0 - 76.0 Option "dpms" EndSection Section "Monitor" Identifier "aticonfig-Monitor[0]" Option "VendorName" "ATI Proprietary Driver" Option "ModelName" "Generic Autodetecting Monitor" Option "DPMS" "true" EndSection Section "Device" Identifier "Videocard0" Driver "vesa" EndSection Section "Device" Identifier "Videocard1" Driver "vesa" VendorName "Videocard Vendor" BoardName "ATI Technologies Inc RV516 [Radeon X1300/X1550 Series]" BusID "PCI:3:0:0" EndSection Section "Device" Identifier "aticonfig-Device[0]" Driver "fglrx" Option "DesktopSetup" "horizontal" EndSection Section "Screen" Identifier "Screen0" Device "Videocard0" DefaultDepth 16 SubSection "Display" Viewport 0 0 Depth 24 EndSubSection SubSection "Display" Viewport 0 0 Depth 16 EndSubSection EndSection Section "Screen" Identifier "Screen1" Device "Videocard1" Monitor "Monitor1" DefaultDepth 16 SubSection "Display" Viewport 0 0 Depth 16 Modes "1920x1200" "1280x1024" "800x600" EndSubSection EndSection Section "Screen" Identifier "aticonfig-Screen[0]" Device "aticonfig-Device[0]" Monitor "aticonfig-Monitor[0]" DefaultDepth 24 SubSection "Display" Viewport 0 0 Depth 24 Modes "1920x1200" "1280x1024" "800x600" EndSubSection EndSection

    Read the article

  • New monitor connected to HDMI adaptor doesn't show output after booting

    - by Paul
    Hello out there in the multiple monitors’ world. I am a very old newbie in your world and need help. I just purchased a new Asus VH236H monitor and hooked it up the HDMI port of an ATI Radeon HD4300 / 4500 Series display adaptor. I left the old Princeton LCD19 (TMDS) hooked up to the DVI port of the same display adaptor. Both monitors displayed the boot sequence, after I fired good old Sarastro2 (Asus P5Q Pro Turbo – Dual Core E5300 – 2.60 GHz) up. The Asus lacked one half of a second behind the Princeton until the Windows 7 Ultimate SP 1 boot up was complete. Then the Asus displayed “HDMI NO SIGNAL” and went into hibernation. The Princeton stayed lit up as before. Both monitors are displayed on the “Screen Resolution Setup Display” and I plaid around with them for a while. The only thing I accomplished was to shove the desktop icons from the Princeton to the still hibernating Asus. The “Multiple displays:” is set to “Extend these displays”, the Orientation is “Landscape” and the Resolutions are set on both to the “recommended” one. Both monitors show that they work properly in the advanced Properties display. What am I doing wrong, what am I missing? Never mind the opinions about the different resolutions of the two monitors. I always can unhook the Princeton and give it to a Goodwill Store if I do not like the setup. I just would like to make it work. Any constructive help is very much appreciated, Thank you.

    Read the article

  • Wireless USB keyboard and mouse can wake system, but then receiver is inactive

    - by BlueMonkMN
    I have a Microsoft brand USB device that acts as a receiver for a wireless Microsoft Keyboard and a wireless Mouse. When it's operating normally, there are LEDs on the device indicating Caps Lock, Num Lock and Function Lock, of which the latter 2 are usually lit. It is plugged into a Dell Isnpiron 531 with Windows 7 32-bit running on an AMD Athlon 64 X2 Dual Core processor 5000+. When the computer goes to sleep (the power indicator on the main box is flashing), I can wake it by moving the mouse. So far all is good. However, something changed in, I think, the past couple weeks (I suspect due to a Microsoft driver update problem). Before the change, after waking the computer, everything would operate normally as far as I could tell, but now after waking the computer, the receiver has no lights on, and the keyboard and mouse are completely unresponsive (which is odd, considering the mouse woke up the computer). There is a button on the receiver that's supposed to reset the wireless connection and flash the lights while it does so, but it has no effect in this state. It's like the receiver doesn't have power (but how would the system know I moved the mouse, unless the power was on until it woke up?). I have checked the BIOS/CMOS settings or whatever you call them, and did not see anything related to USB in the power management section. I have checked Windows 7 device manager and ensured that all the USB Root Hub devices have the setting unchecked for allowing the USB power to be turned off. Like I said, this was working before, and the only thing I can think of that's changed is applying Windows Updates.

    Read the article

  • Configuring WPA WiFi in Ubuntu 10.10

    - by sma
    I am trying to configure my wireless network on my laptop running Ubuntu 10.10 and am having a bit of difficulty. I am a complete Linux newb, but want to learn it, hence the reason I'm trying to set this up. Here's the vitals: It is a Gateway 600 YG2 laptop. It was previously running Windows XP, but I installed Ubuntu 10.10 in place of it (not a dual boot, I removed XP altogether). I have an old wireless card that I'm trying to resurrect. I haven't really used the card in a couple years, but it seems to still work, I just can't connect to my home's wireless network. The card is a Linksys WPC11 v2.5. When I plug it in, Ubuntu recognizes the network, but won't connect to it. My home network uses WPA encryption and the only connection type that Ubuntu's network manager is giving me is WEP and then it asks for a key -- I have no idea what that key should be. So, basically, I'm asking, is there a way I can instead connect through WPA? I've tried creating a new connection in network manager, but that won't work, it keeps falling back to the WEP connection and asking me for a key. I have tried to install the XP driver using ndiswrapper but I don't know if that's working or not. Is there a way to tell if: A) the card is working as it should B) the correct drivers are installed (again, I installed the XP one using ndiswrapper NET8180.INF, but I'm not sure what to do next) Any help would be appreciated. Thank you.

    Read the article

  • Two instances of Windows Vista on boot up after failed clean install

    - by Dwayne
    I tried to install a clean version of Vista but failed. I ended up with Windows and Windows.old on my C: drive and a dual boot option on boot up. I gave up and booted up the old version and tried to rename the Windows.old to Windows and was asked if I wanted to merge the two folders. I answered yes and all seemed OK until I booted up this morning and was given the choice of two versions of Vista. The first one is the one that failed to installed correctly and the second one is the old version. How can I get rid of the failed installation? I got rid of the bad boot via MSCONFIG. Here is my current situation: several hard drives installed Using C: as my boot drive a much larger drive (H:) for storing most of my files. I found a subfolder in my C:\windows folder named windows. Upon inspection I determined it to be older than the C:\windows folder and therefore it must be the older, working version of the boot. I renamed the C:\windows folder to c:\windows.bad and moved the sub windows to the C: root directory. I also copied it to the h: drive. Now MSCONFIG reports that the copy that is booting is the h: copy. How can I change it back to the C:\ copy and can I delete the C:\windows.bad file set?

    Read the article

  • Intel Rapid Storage Technology (pre-OS) driver installation

    - by Nero theZero
    My desktop machine is built on Gigabyte GA-Z87-UD3H and Gigabyte provides the latest driver for Intel Rapid Storage Technology (IRST), which I installed after installing the OS. Same goes for my Lenovo Thinkpad-T420. And for both machine, checking the controller device under the IDE ATA/ATAPI Controllers section in Device Manager I see the driver has been updated to the latest version. I set the SATA controller to AHCI from BIOS On the desktop machine I have one WD 2TB BLACK & one WD 3TB Green I don’t use RAID, & no chance of using in near future, but according to Intel IRST improves performance in single disk scenario too. Now I have the following questions – What is the actual purpose of IRST (pre-OS install) driver that doesn’t get served with a post-OS driver that I installed? There must be some difference, otherwise there wouldn’t be a pre-OS version of the driver. Right? In the pre-OS procedure (loading the drivers at OS-installation time) after successfully completing the OS installation, do I need that post-OS driver? Because after installing from that one I got a quick launch icon that runs the IRST configuration application. Where do get that after installing the pre-OS driver? As it is “pre-OS”, when I load it at OS-installation time, does it updates anything at BIOS level or anywhere other than HDD? That’s because I’m going to dual boot Windows 7 with Windows 8.1, and after installing Windows 7 when I install Windows 8.1 & load the IRST driver for that, is there any chance of any “overwriting” or OS-incompatibility? In short, is there anything specific to follow while installing the second OS?

    Read the article

  • LCD monitor flicker when connected to a laptop using VGA

    - by Björn Lindqvist
    I have a dual screen setup with two AOC e2450Sw monitors connected to a laptop. The laptop has one HDMI and one VGA output. When one of the monitors is connected using VGA, it flickers or displays static noise. The flickering is fairly subtle and only visible on darker colors. But it is there and noticable and appears like horizontal lines. The problem only appears on the monitor connected to the laptop using the VGA cable. If I swap the monitors, the one connected using VGA is displaying the flicker but not the one connected using HDMI. The simple solution would ofcourse be to connect both monitors using HDMI, but since the laptop only has one VGA and one HDMI out that isn't possible. I've tried tweaking the monitor setting using the OSD menu, but it had little or no effect. Update: After several more trouble shooting hours, it seems the problem is not related to the monitor or VGA cable as the problem persists even if I swap the display with another brand and different cables. So it may be the graphics card? Intel HD Graphics 4000. The laptop is Acer Aspire E1-571.

    Read the article

  • Windows Server 2008 R2 install reboots unexpectedly during "Completing installation" phase

    - by knda
    I am attempting to install Windows Server 2008 R2 onto a Cisco UCS C201 M2 rack mounted server but am having major difficulties and wondering if anyone has some insight or items they could recommend for me to look at to get this one resolved. Installation is being attempted via the Cisco remote console (using CIMC's Virtual dvd-rom).. following the first phase of Setup where the installation files are copied to the target hard drive, then a reboot occurs to load Setup from the HDD, mid-way in the "Completing Installation" phase the system then reboots unexpectedly. System configuration Cisco UCS C201 M2 (2RU rack mounted server) 16GB RAM, 2x 73GB 15K SAS, 4x 300GB 10k SAS Add-on cards - Intel quad-port GigE card (no fibre channel cards) Storage - LSI MegaRAID SAS 9261-8i. onboard SATA is disabled (no SATA drives connected) KVM - Belkin No physical DVD-ROM.. :( I have... Run memtest86+, no RAM faults Disabled/enabled SATA support (BIOS) Attempted install from USB DVD-ROM, no effect Attempted unattended install scripted via Cisco Configuration Manager DVD provided Removed Belkin KVM in case that was causing drama Discovered that the Cisco website is "awesome" for searching for PDFs/Drivers cough, reverted back to Google Downloaded latest LSI drivers from LSI's site and used during Server 2008 install checked Windows ISO against checksum's from MS site checked Windows ISO by using it for an install in a VM Running out of ways to troubleshoot this as I am not sure how to enable any sort of 'verbose' mode during the setup process. Next step I have planned is to remove the Intel NIC and try the installation again.. Edit: Problem was the "Cisco INTEL QUAD PT GBE" (1000/PT) .. will have to see if this card is faulty or if it's just drivers.. thanks for the help.

    Read the article

  • Dell Poweredge 1950 with Perc 5i keeps losing raid config -> "Foreign Configuration Found"

    - by nosage
    The quick and dirty: the machine is a Dell Poweredge 1950, dual xeon quad cores, 8GB of ram, 2 2TB seagate SATAs in (supposed to be raid1) using a Perc 5i raid card. They are hot-swappable with a back-plane. I can build the raid fine and after a little while an install of server 08 r2 will blue screen and restart. When it comes up the raid controller says "Foreign Configuration Found." When I go into the raid configuration panel there is no raid listed but I can import the "foreign config", and the OS will boot up fine, until it blue screens again after a little while. The issue is OS independent. I have tried swapping raid cards, swapping the RAM module on the raid card and swapping the raid battery, all to no avail. Its almost as if there is a loose connection from the raid card to the back plane and both of disks get lost and the raid card drops the config. But it sees the disks fine when it boots back up. The raid card uses a SCSI SAS cable to connect to the back-plane so I guess the next step is to replace that, but... then I might as well replace the back-plane with a SCSI SAS to sata breakout cable, but... then I need a way to power the disks. Sorry for the wall of txt but it would be great to get some thoughts from people who worked with perc raid cards or poweredge servers with this type of issue before. Ironically I want to get this system up and running so I can work on MCITP labs. Thank you for any/all help and feel free to ask questions!

    Read the article

  • Request bursting from web application Load Tests

    - by MaseBase
    I'm migrating our web and database hosting to a new environment on all new machines. I've recently performed a Load Test using WAPT to generate load from multiple distributed clients. The server has plenty of room to handle the traffic load, but I'm seeing an odd pattern of incoming traffic during the load tests. Here is the gist of our setup: Firewall server running MS Forefront TMG 2010 on Win 2k8 server Request routing done by IIS Application Request Routing on firewall machine Web server is a Hyper-V VM on the Database server (which is the host OS) These machines are hefty with dual-CPU's with six cores (12 total procs) Web server running IIS 7.5 Web applications built in ASP.NET 2.0, with 1 ISAPI filter (Url Rewrite) in front What I'm seeing during the load tests is that the requests all come through in bursts. Even though I have 7 different distributed clients sending traffic loads, the requests come through about 300-500 requests at a time. The performance monitor shows nearly all of the counters moving through this pattern, where a burst of requests comes in the req/sec jumps to 70, the queued requests jumps to 500, the current requests jumps up, the CPU jumps up, everything. Then once it's handled that group of requests, it has a lull for nearly 10 seconds where nearly nothing is happening. 0-5 req/sec, 0 queued requests, minimal CPU usage. Then after 10 seconds of inactivity, another burst comes through, spiking all of the counters once again. What I can't figure out is why the requests are coming through in bursts when I know that the load being generated is not sent that way, especially considering the various load-generating clients sending traffic all in different intervals with random think time's between each request. Is there something in the layers between Hyper-V or perhaps in the hardware which might cause this coalesce of requests together? Here is what i'm looking at, the highlighted metric is Requests/sec, but the others critical counter go with it: Requests Queued (which I'd obviously like to keep as close to 0 as possible). Any ideas on this?

    Read the article

< Previous Page | 183 184 185 186 187 188 189 190 191 192 193 194  | Next Page >