Search Results

Search found 5716 results on 229 pages for 'dual channel'.

Page 191/229 | < Previous Page | 187 188 189 190 191 192 193 194 195 196 197 198  | Next Page >

  • Virtual machines with failover setup

    - by kimmmo
    We have three servers and our plan is to run a number of virtual machines on them in such manner, that if one of the nodes blow up, we can either quickly or seamlessly get a spare running on another node. In addition to the normal networking, they're interconnected via dual 10Gbit NIC's, so networked raid/mirroring shouldn't be a problem. The guest VM's are mostly going to be running text mode linux, but of course it wouldn't hurt to be able to spin up a non-mission critical windows guest for running Visual Studio or checking IE compatibility of a web app. We've spent some time trying to get some magical cloud setup running using Stackops and Crowbar but it started to look like they were offering way too much and were too complicated for our needs. The next candidate, I think, is Ubuntu 11.04 server + KVM + Ganeti + Drbd, unless you can come up with a suggestion for a better solution that we have missed. Requirements: Installation should be simple or at least understandable without being in the dev team A browser interface for creating and managing VM's is a nice bonus Single node's hardware failure should cause minimal downtime for VM's that were running on that node Adding more nodes should be possible without shutting down the VM's.

    Read the article

  • sata hard drive failed

    - by M. Shehryar
    Dear friend, initially my dual core PC started shutdown and re-start by itself after adding 1 GB ram and up-grading the graphic card. Then refused to boot. I restored the window ghost but failed to boot. I tried to install new window but installation failed after coping the window files. tried to install old vista lonhorn. It inspected found errors, fixed them but ultimatly failed to be installed. Once again restored the ghost through acronis but failed to boot. At the end attached as slave with another pc but it was not visible. Even acronis could not see it or its partitions. Only bios can see it. It seems that no file system is available on the drive. My data on drive is very important. Please help me how to revover my data. Drive brand is Samsung, cap is 160 GB and file system was NTFS.

    Read the article

  • Troubleshooting a Windows 7 PC that wouldn't sleep

    - by NPE
    I have a new Windows 7 PC that wouldn't sleep (not just automatically, but also when specifically told to). The screen goes black momentarily, but within two seconds the machine comes back as if nothing has happened. I tried powercfg energy. This produces some errors quoted at the bottom of this post, plus some warnings about timer resolution. There are no USB devices connected other than wireless keyboard + mouse (Logitech MK250); I tried unplugging them to no effect. The motherboard is Asus P7P55D-E. powercfg lastwake says "Wake History Count - 0", which I take to mean that it never actually went to sleep. I dual boot into Ubuntu, and was having exactly the same problem on the Linux side. That turned out to do with USB 3.0, which I've now disabled in the BIOS. This has solved the problem on the Ubuntu side of things, but made no difference to Windows 7. Any suggestions? Suspend:USB Device not Entering Suspend The USB device did not enter the Suspend state. Processor power management may be prevented if a USB device does not enter the Suspend state when not in use. Device Name Generic USB Hub Host Controller ID PCI\VEN_8086&DEV_3B34 Host Controller Location PCI bus 0, device 29, function 0 Device ID USB\VID_8087&PID_0020 Port Path 1 USB Suspend:USB Device not Entering Suspend The USB device did not enter the Suspend state. Processor power management may be prevented if a USB device does not enter the Suspend state when not in use. Device Name USB Root Hub Host Controller ID PCI\VEN_8086&DEV_3B34 Host Controller Location PCI bus 0, device 29, function 0 Device ID USB\VID_8086&PID_3B34 Port Path USB Suspend:USB Device not Entering Suspend The USB device did not enter the Suspend state. Processor power management may be prevented if a USB device does not enter the Suspend state when not in use. Device Name USB Composite Device Host Controller ID PCI\VEN_8086&DEV_3B34 Host Controller Location PCI bus 0, device 29, function 0 Device ID USB\VID_046D&PID_C52E Port Path 1,8

    Read the article

  • Should I partition a 1TB Hard Disk whose primary use is media storage?

    - by Senthil
    I am going to get a 1TB hard disk. I will be storing 1080p or 720p movies, high-bitrate music and pictures in it. I use my PC 90% of the time only to play/listen/see those. I am running out of space in my current HD so I am getting another one. My specs are 2.7GHz Dual Core, 512MB GeForce 9400GT, 2GB DDR2 RAM and all the proper matroska codecs/players. I guess that is enough to play 1080p movies withough a glitch, given an ideal hard disk. I've read about proper partitioning giving performance improvement etc.. I don't want my hard disk to be the bottleneck. Can someone tell me whether I should partition my 1TB hard disk into many drives? If I should, what is the ideal size of each partition? Smooth playing of movies is very important to me. Once I start filling up the disk, there is no turning back. So I want to get it right before I start. Thanks.

    Read the article

  • MD RAID 1 with external bitmap doesn't fully resync

    - by user64744
    I have an interesting configuration: dual boot system with a RAID 1 that needs to be visible in both Windows and Linux. The Windows install is Win 7 Enterprise, and the Linux install is Kubuntu 10.04. To get the RAID to work, I set it up using Windows's "Dynamic Disks" RAID 1, and brought it up in Linux using MD with no persistent superblock, and a write-intent bitmap on another partition. (Without this bitmap, MD had no way of knowing that the array was in sync, and would do a complete resync every time the array started.) The array is assembled like so: mdadm --build /dev/md1 -l 1 -n 2 -b /var/local/md1.bitmap /dev/sdb2 /dev/sdc2 I expected that the first time I ran this command, it would resync the array, write out a bitmap with no dirty chunks, and all would be good. This wasn't the case: after completing the resync, the bitmap was mostly clean, but about 5% dirty blocks remained, as revealed by mdadm -X /var/local/md1.bitmap I didn't mount the filesystem on /dev/md1 or touch it in any other way. I then found that stopping and restarting the array: mdadm --stop /dev/md1 mdadm --build /dev/md1 -l 1 -n 2 -b /var/local/md1.bitmap /dev/sdb2 /dev/sdc2 did indeed read in the bitmap, with an ensuing resync that went quickly because most of the blocks were marked clean. The confusing part is that this resync further reduced the number of dirty blocks, but still did not remove all of them. By repeatedly stopping and restarting I could slowly bring the dirty block count down to around 0.6%, where it seemed to level out. Any ideas what could be causing this? It smells to me of a race condition somewhere that leads to blocks either being skipped over during synchronization or not properly cleared from the bitmap, but I really have no evidence to prove this. It doesn't look like hardware issues since both drives are new and have zero read errors and reallocated sectors reported by smartctl -a.

    Read the article

  • sata hard drive failed

    - by M. Shehryar
    Dear friend, initially my dual core PC started shutdown and re-start by itself after adding 1 GB ram and up-grading the graphic card. Then refused to boot. I restored the window ghost but failed to boot. I tried to install new window but installation failed after coping the window files. tried to install old vista lonhorn. It inspected found errors, fixed them but ultimatly failed to be installed. Once again restored the ghost through acronis but failed to boot. At the end attached as slave with another pc but it was not visible. Even acronis could not see it or its partitions. Only bios can see it. It seems that no file system is available on the drive. My data on drive is very important. Please help me how to revover my data. Drive brand is Samsung, cap is 160 GB and file system was NTFS.

    Read the article

  • GA 8KNXP Rev1.0: 4GB installed, only 3.5 recognized by BIOS

    - by hurikhan77
    I've installed 2x 1 GB and 4x 512 MB memory into my GA-8KNXP system which would sum up to 4GB. The specs from the manual say: Maximum memory support: 4GB. If all six slots are utilized, slot 5+6 may only equipped with single-sided RAM modules. And so I did. Anyway: The BIOS counts up to 3.5 GB and finishes there. Also my linux system reports only 3.5 GB of memory although 4 GB memory support is activated in the kernel. So I suppose this is a memory mapping issue or a hardware issue. I've tried removing only on of the 512 MB memory modules leaving 5 modules in place. But that just stopped the system from powering on correctly (screen stays black although fans and leds come to live). Dual Channel was detected and enabled so the system technically found all 6 modules. "dmidecode" in linux reports only memory in slots 1 to 4 and ignores slots 5+6, so it only detects 3 GB of memory. It also says the system would support up to 16 GB of memory with 4 GB modules per slot. I think technically the chipset should be able to offer and utilize the complete 4 GB memory range. Any clues what else I could check? Or do I have just to live with 0.5 GB wasted memory?

    Read the article

  • Home Server: cpu virtualisation, what to choose?

    - by Huygens
    I'm looking for virtualisation solutions for storage and OS for a home server. A sort of private cloud where I manage the storage space independently of the VM one. This question focus on VM (or compute instance) management and what would best suit my needs. (I have another question related to the storage management). My use cases are: A backup server: rsync and other services running. A personal cloud server: a kind of owned dropbox system, à la ownCloud. " users foreseen. A media server: streaming videos and displaying photos. Here my environement and wishes: Server: HP Proliant MicroServer with 8 GB RAM (AMD Turion dual core with AMD-V technology) OS types: only Linux (perhaps a *BSD VM in the future) Linux distributions do not matter, I'm familiar with RHEL, Fedora, Suse, Ubuntu, but any other recommandation will be fine 2-3 VMs foreseen: backup server, owncloud server and media server (optional). Those are only servers, so no graphical console needed (I don't need VirtualBox) By VM I mean a virtualised environment like KVM, Xen, etc. or a compute instance like with OpenStack storage should be "virtualised/cloudified" see my other question. VM should be able to be migrated to another server in the future if performance cannot be fullfilled anymore by the current server It does not matter if installation of such setup is complicated as long as management tools allow for easy maintenance I don't have Windows at home, so solution should be Linux friendly and would be nice to be web based. But native apps are OK too. System should be easy to enhance: by adding a new server to migate some of the VMs to it. So it's really a kind of private cloud on which I could run some Linux OS. I would prefer free (libre, as in a free speach) and open source tools. But it does not have to be free as in a free beer. So Xen, KVM, VitualBox or OpenStack? What would you recommend?

    Read the article

  • What laptop would be recommended for video-editing or transcoding to blu-ray?

    - by Rob
    I'm looking for a machine (has to be a laptop) reasonably fast enough to handle editing/transcoding/rendering to Blu-ray disc of full true HD 1080p (1920x1080) video from a Samsung R10 camcorder - MPEG4 25fps (not the Sony-Panasonic AVCHD format): To be able to browse through the footage (say, quarter screen is fine for monitoring) and do simple edits - cut out bad bits, add titles, fades, nothing too fancy To be able to burn the footage in 1920x1080p 24p (twenty-four) fps to blu-ray, probably don't mind if I have to leave it for a few hours, or even overnight, as long as its not still running in the morning or takes days. I ALREADY have an external USB 2.0 LG BE06LU10 blu-ray burner. Does quad core make much difference? Or would Dual-core suffice for the above? NVidia because of CUDA for increased speed. What software today can take advantage of this? Which graphics card do I need? So far I've found Dell/Alienware to be well-specified, having a 5yr old Dell laptop that still runs well, albeit slow by today's standards, gives me a good impression. My concerns are too much fan-noise and budget and some Dell Precision Laptops exceed 1500 pounds. Thoughts?

    Read the article

  • Decyphering Seagate drive model numbers?

    - by Stefan Lasiewski
    I'm comparing Seagate's Enterprise and Desktop drives for a variety of old and new servers. These servers come from different generations, so options like size (73GB, 2TB) and interface (SATA vs SAS 3.0Gbps vs SAS 6Gbps vs SCSI Ultra320) are widely variable. I'm trying to compare the sizes, speeds and interfaces, but I'm getting thrown off by different models. Also, their website is not the best. Does anyone know of a documented explanation of the Seagate model numbers? And is there a single spreadsheet which compares the features for all drives (or all 'Enterprise' drives?). Seagate drives have model numbers like this: Model ST3600057SS 6-Gb/s SAS 600 GB None at Cheetah® 15K Hard Drives Model ST373455LW Ultra320 SCSI 73.4 GB 68-Pin LW at Cheetah® 15K Hard Drives Model ST32000644NS SATA 3Gb/s 2 TB None at Constellation™ ES Hard Drives Model ST973452SS 6-Gb/s SAS 73 GB None Savvio® 15K Hard Drives Model ST9200011FS SATA 3Gb/s 200 GB Pulsar™ Solid State Drives I understand the model numbers read something like this: ST - SOMETHING1 - SIZE - SOMETHING2 - INTERFACE Where the fields mean something like this: ST : For 'Seagate'? 'Seagate Technoligies'? SOMETHING1 - This field has number, but I'm not sure what that represents. SIZE - Size in Gigabytes. This is a number like '73' or '300' or '2000' SOMETHING2 - This field also has a number, but I'm not sure what it means. INTERFACE - This field seems to indicate the Interface. 'SS' means SAS, 'FC' means Fibre Channel, but I don't see how to distinguish between 6Gbps SAS and 3Gbps SAS, or different SATA or FC speeds. I don't see a field which indicates the RPM (15K , 10K, 7.2K) etc. Is this part of the model number?

    Read the article

  • Connecting jconsole using SOCKS to Amazon EC2

    - by freshfunk
    I'm trying to use jconsole to view stats on an EC2 instance by using a socks proxy created by SSH. I've tried the various scripts mentioned in the links below but to no avail: http://simplygenius.com/2010/08/jconsole-via-socks-ssh-tunnel.html http://gabrielcain.com/blog/2010/11/02/using-ssh-proxying-to-connect-jconsole-to-remote-cassandra-instances/ I'm running ssh -f -ND 8123 myuser@mymachine and verified that at least Firefox goes through it as a proxy. I then run jconsole -J-DsocksProxyHost=localhost -J-DsocksProxyPort=8123 service:jmx:rmi:///jndi/rmi://ec2-XX-XX-XXX-XXX.compute-1.amazonaws.com:8080/jmxrmi I run netstat -n on my EC2 instance and I see a connection created by my machine. However, the connection eventually disappears and I get a 'channel 2: open failed: connect failed: Operation timed out' from my ssh tunnel. I've opened the jmx port through the security group and I've checked the port on the EC2 instance to make sure it's open (by telnet-ing to it). I'm not sure where to look next. Are there some properties in sshd_config or ssh_config I need to enable for tunneling? Or anything in Mac OS X? I feel like a serious noob but sys administration is really not my strong point. I've spent several hours and can't get this to work.

    Read the article

  • ZFS with L2ARC (SSD) slower for random seeks than without L2ARC

    - by Florian Kruse
    I am currently testing ZFS (Opensolaris 2009.06) in an older fileserver to evaluate its use for our needs. Our current setup is as follows: Dual core (2,4 GHz) with 4 GB RAM 3x SATA controller with 11 HDDs (250 GB) and one SSD (OCZ Vertex 2 100 GB) We want to evaluate the use of a L2ARC, so the current ZPOOL is: $ zpool status pool: tank state: ONLINE scrub: none requested config: NAME STATE READ WRITE CKSUM afstank ONLINE 0 0 0 raidz1 ONLINE 0 0 0 c11t0d0 ONLINE 0 0 0 c11t1d0 ONLINE 0 0 0 c11t2d0 ONLINE 0 0 0 c11t3d0 ONLINE 0 0 0 raidz1 ONLINE 0 0 0 c13t0d0 ONLINE 0 0 0 c13t1d0 ONLINE 0 0 0 c13t2d0 ONLINE 0 0 0 c13t3d0 ONLINE 0 0 0 cache c14t3d0 ONLINE 0 0 0 where c14t3d0 is the SSD (of course). We run IO tests with bonnie++ 1.03d, size is set to 200 GB (-s 200g) so that the test sample will never be completely in ARC/L2ARC. The results without SSD are (average values over several runs which show no differences) write_chr write_blk rewrite read_chr read_blk random seeks 101.998 kB/s 214.258 kB/s 96.673 kB/s 77.702 kB/s 254.695 kB/s 900 /s With SSD it becomes interesting. My assumption was that the results should be in worst case at least the same. While write/read/rewrite rates are not different, the random seek rate differs significantly between individual bonnie++ runs (between 188 /s and 1333 /s so far), average is 548 +- 200 /s, so below the value w/o SSD. So, my questions are mainly: Why do the random seek rates differ so much? If the seeks are really random, they should not differ much (my assumption). So, even if the SSD is impairing the performance it should be the same in each bonnie++ run. Why is the random seek performance worse in most of the bonnie++ runs? I would assume that some part of the bonnie++ data is in the L2ARC and random seeks on this data performs better while random seeks on other data just performs similarly like before.

    Read the article

  • How to edit known_hosts when several hosts share the same IP and DNS name?

    - by Frédéric Grosshans
    I regularly ssh into a computer which is a dual-boot OS X / Linux computer. The two OS instance do not share the same host key, so they can be seen as two host sharing the same IP and DNS. Let's say the IP is 192.168.0.9, and the names are hostname and hostname.domainname As far as I understood, the solution to be able to connect to the two host is to add them both to the ~/.ssh/know_hosts file. However, it is easier said than done, because the file is hashed, and has probably several entries per host (192.168.0.9, hostname, hostname.domainname). As a consequence, I have the following warning Warning: the ECDSA host key for 'hostname' differs from the key for the IP address '192.168.0.9' Is there an easy way to edit the known_hosts file, while keeping the hashes. For example, how can I find the lines corresponding to a given hostame? How can I generate the hashes for some known hosts? The ideal solution would allow me to connect to seamlessly to this computer with ssh, no matter whether I call it 192.168.0.9, hostname or hostname.domainname, nor if it uses its Linux hostkey or its OSX hostkey. However, I still want to receive a warning if there is a real man-in-the middle attack, i.e. if another key than these two is used.

    Read the article

  • Monitor displays at 1024x768; scrolls screen for higher resolutions

    - by Matt
    I have a dual monitor setup. Normally, they both display at 1680x1050. They have been setup this way for about a year. I'm using Windows XP Professional 2003 x64 SP2. Today, out of nowhere, one of the monitors kicked back to a lower resolution. I was not playing with any configuration at the time.. in fact all I had done was close a window (maybe a browser). But the thing is that the resolution is still preserved partially by the fact that the screen will scroll when you move the mouse. So it's like looking through a 1024x768 window into a 1680x1050 world. The monitor itself does not appear to be damaged, because I also have it connected to my netbook (via KVM) and higher resolutions work fine. I tried uninstalling/reinstalling the drivers to no avail. System restore doesn't help either. I'm unsure of the exact ATI card I'm using.. Device Manager lists it as "Radeon X300/X550/X1050". There is no Catalyst Control Center software installed. I tried to install it, but there doesn't seem to be a way to install it by itself ... it forces you to install another driver, which breaks both of my displays, forcing me to go into safe mode and run system restore again. Any ideas? Thanks

    Read the article

  • Connection refused in ssh tunnel to apache forward proxy setup

    - by arkascha
    I am trying to setup a private forward proxy in a small server. I mean to use it during a conference to tunnel my internet access through an ssh tunnel to the proxy server. So I created a virtual host inside apache-2.2 running the proxy, the proxy_http and the proxy_connect module. I use this configuration: <VirtualHost localhost:8080> ServerAdmin xxxxxxxxxxxxxxxxxxxx ServerName yyyyyyyyyyyyyyyyyyyy ErrorLog /var/log/apache2/proxy-error_log CustomLog /var/log/apache2/proxy-access_log combined <IfModule mod_proxy.c> ProxyRequests On <Proxy *> # deny access to all IP addresses except localhost Order deny,allow Deny from all Allow from 127.0.0.1 </Proxy> # The following is my preference. Your mileage may vary. ProxyVia Block ## allow SSL proxy AllowCONNECT 443 </IfModule> </VirtualHost> After restarting apache I create a tunnel from client to server: #> ssh -L8080:localhost:8080 <server address> and try to access the internet through that tunnel: #> links -http-proxy localhost:8080 http://www.linux.org I would expect to see the requested page. Instead a get a "connection refused" error. In the shell holding open the ssh tunnel I get this: channel 3: open failed: connect failed: Connection refused Anyone got an idea why this connection is refused ?

    Read the article

  • How to Log Into a Web App Simultaneously with Different Account?

    - by Ngu Soon Hui
    I want to log into a web application, using at least ten account names at one single point of time ( I am not trying to do anything illegal, so don't worry). AFAIK, each tab in Chrome will share the same session, therefore, for one machine, one can use Google Chrome to log in at most 2 accounts, one in normal mode, another in Incognito mode. Is there anyway I can log into multiple accounts? I know I can open up IE and Firefox ( probably Safari etc) and login, but this is not really scalable as the number of web browsers is finite. Edit: My application is a localhost application; it resides on my computer. So proxy may not be that useful, and you now probably understand why it's nothing illegal. Edit2: CookieSwap seems like a good idea, but the problem is that once I swap the cookie, all the tabs and the FF apps' cookie are swap as well. Can the swapping be done on a tab basis or on application basis, so that on a dual-monitor, I can see the different login side-by-side?

    Read the article

  • Why Is Volume Shadow Copy Services stopping?

    - by David Mackintosh
    I am running Windows 7 Professional, 64-bit. I am running a backup-over-the-internet software client which depends on the Volume Shadow Copy Services running. Since I installed Service Pack 1 (or rather, didn't object when Windows Update forced Service Pack 1 on me) the backup service is failing to back everything up because VSC isn't running. Most of the time it fails to back up such noise as the Security Essentials database or the Messenger Live contact list -- stuff I really don't care about -- but I don't want to fall into the trap of accepting an Error-state backup as "normal". At the recommendation of the backup software, I have set the VSC service startup mode to be Automatic. When I look in the Event Log, System channel I can see at boot time: The Volume Shadow Copy service entered the running state. ...and then two or three minutes later: The Volume Shadow Copy service entered the stopped state. How do I figure out why VSC is stopping? At the suggestion of the backup vendor, I have already followed the suggestions from http://support.microsoft.com/default.aspx/kb/940184 net stop SENS net stop EventSystem net start EventSystem net start SENS net stop COMSysApp net stop SwPrv net stop VSS cd /d C:\Windows\system32 regsvr32 ole32.dll /s regsvr32 oleaut32.dll /s regsvr32 vss_ps.dll /s vssvc /register /s regsvr32 /i swprv.dll /s regsvr32 /i eventcls.dll /s regsvr32 es.dll /s regsvr32 stdprov.dll /s regsvr32 vssui.dll /s regsvr32 msxml.dll /s regsvr32 msxml3.dll /s regsvr32 msxml4.dll /s net start SwPrv net start VSS net start ProtectedStorage ...and per http://support.microsoft.com/kb/940184 I have deleted the key tree HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\EventSystem\{26c409cc-ae86-11d1-b616-00805fc79216}\Subscriptions I have also run chkdsk /F and chkdsk /R on both permanent hard disks. (I had a similar problem with another computer (same OS, same failure, same start point after SP1 install) but the problem went away when I forced Volume Shadow Copy Services to Automatic startup rather than Manual. I did not have to resort to following the Microsoft KB instructions.)

    Read the article

  • bootmgr image is corrupt

    - by bacord
    I just replaced my HD with a SSD. I did a brand new install on the SSD and I received the following error after booting BOOTMGR image is corrupt. The system cannot boot. A little configuration for your knowledge. The system used to be a dual boot with XP & windows 7. After replacing the original startup HD with my SSD I changed a setting in the bios to AHCI (I have tested changing it back but this did not help). When I look at the stats on the drive in the bios, it claims that the SSD is in a raid configuration despite the settings not being configured that way. Related System Information: Intel 320 Series 80 GB Sata II SSD JetWay JPA78VM3-H-LF AM2+/AM2 AMD 780V HDMI Micro ATX AMD Motherboard AMD Athlon 64 X2 7 GB ram I have performed 2 fresh installs to no avail. Also, followed this guide and performed option 1 and 2. I have done bootsec/fixmbr and /fixboot. So.. any suggestions?

    Read the article

  • Getting Dell E6320 with I7 to work with 3 monitors at 1920x1080p x 3

    - by MadBoy
    I want to buy Dell E6320 which comes with Intel Core I7-2620M (2.70GHz, 4MB cache, Dual Core) with Intel HD Graphics 3000. Laptop will come with docking station. I want to connect 3 monitors to that docking station so that working at home would give me some additional boost. Docking station will allow me to connect only 2 monitors so I'm looking at following other options: Matrox TRIPLEHEAD2GO DIGITAL Edition or TRIPLEHEAD2GO DP Edition. But reading Matrox Support Page intel GPU can't run the highest resolution with 3 monitors connected, it even gets worse since it seems monitors would have to be able to work at 50hz. Also I'm not sure but it seems that Matrox doesn't split the monitors as 3 separate monitors but simply as one big space (which is a bit opposite to what I need) Buy 2 or maybe just 1 USB based monitor but it would also mean having 1 or 2 different monitors then the main one, unless I buy 3 USB based monitors which would mean more money to spend. Also I found only couple of models and most of them require USB 3.0 and no other cables to plug in (nice but costly - couldn't find decent monitor with only USB for sending signal and having power connected normally) . But docking station has only one USB 3.0 port. Can I use hub and still get it to work? Find some converters from Digital to USB (I think DisplayLink does some?) Buy different laptop but what kind? I need it to be I7, small (13"), fast and lightweight. At same time it requires docking station that I can use at home to connect 3 external monitors. Some other suggested solution... Edit: I need 3 monitors for work in terms of coding in Visual Studio or having word/excel/outlook open. Nothing fancy. Maybe some movie once in a while.

    Read the article

  • How to best tune my SAN/Initiators for best performance?

    - by Disco
    Recent owner of a Dell PowerVault MD3600i i'm experiencing some weird results. I have a dedicated 24x 10GbE Switch (PowerConnect 8024), setup to jumbo frames 9K. The MD3600 has 2 RAID controllers, each has 2x 10GbE ethernet nics. There's nothing else on the switch; one VLAN for SAN traffic. Here's my multipath.conf defaults { udev_dir /dev polling_interval 5 selector "round-robin 0" path_grouping_policy multibus getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout none path_checker readsector0 rr_min_io 100 max_fds 8192 rr_weight priorities failback immediate no_path_retry fail user_friendly_names yes # prio rdac } blacklist { device { vendor "*" product "Universal Xport" } # devnode "^sd[a-z]" } devices { device { vendor "DELL" product "MD36xxi" path_grouping_policy group_by_prio prio rdac # polling_interval 5 path_checker rdac path_selector "round-robin 0" hardware_handler "1 rdac" failback immediate features "2 pg_init_retries 50" no_path_retry 30 rr_min_io 100 prio_callout "/sbin/mpath_prio_rdac /dev/%n" } } And iscsid.conf : node.startup = automatic node.session.timeo.replacement_timeout = 15 node.conn[0].timeo.login_timeout = 15 node.conn[0].timeo.logout_timeout = 15 node.conn[0].timeo.noop_out_interval = 5 node.conn[0].timeo.noop_out_timeout = 10 node.session.iscsi.InitialR2T = No node.session.iscsi.ImmediateData = Yes node.session.iscsi.FirstBurstLength = 262144 node.session.iscsi.MaxBurstLength = 16776192 node.conn[0].iscsi.MaxRecvDataSegmentLength = 262144 After my tests; i can barely come to 200 Mb/s read/write. Should I expect more than that ? Providing it has dual 10 GbE my thoughts where to come around the 400 Mb/s. Any ideas ? Guidelines ? Troubleshooting tips ?

    Read the article

  • Troubleshooting wireless client-bridged networks between two DD-WRT routers?

    - by KronoS
    I recently purchased a Buffalo N600 wireless router which came with DD-WRT pre-installed. I want to take my old wireless router a Linksys WRT54GL, also with DD-WRT pre-installed, and use it as a wireless bridge for my HTPC and Blu-Ray Player in the other room. I other words, I'm trying to connect to WIRED networks via the wireless on the routers. I followed eactly the instruction from DD-WRT's manual for 'Client Bridged' however I'm still not able to connect to two routers correctly, when the encryption is enabled (WPA2-Personal Mixed) however I am able to connect the two routers when there is NO encryption. I've checked, double checked, and triple checked that EVERYTHING is the same on BOTH routers: Routers 1 & 2 Encryption: WPA2-Personal Mixed Wireless Mode: G-Only Wireless Channel: 6 Subnet Mask: 255.255.255.0 Subnet: 192.168.1.0/254 SSID: Krono$ Primary Router #1 (Buffalo N600) IP Address: 192.168.1.1 Firewall: Enables w/ defaults DCHP: Enabled as DHCP Server Secondary Router #2 (Linksys WRT54GL) IP Address: 192.168.1.2 Firewall: Disabled as per DD-WRT instructions I'm looking for any configurations that I may have missed, or settings that may need to happen in order for this work.

    Read the article

  • VMWare Raw Device Mapping Not Working

    - by George H. Lenzer
    While I'm waiting for VMWare support to get back to me, I thought I'd ask here. I have a 400 gig LUN presented from a fiber channel SAN to my VMWare host. It's legacy from another virtualization platform and I need to keep it as is to avoid a long period of downtime. I formatted my VMFS3 datastore with 4 meg blocks to allow up to 1 TB disks. Then I tried adding my 400 gig disk as a raw device in physical compatibility mode. I get the error: "File is larger than the maximum size supported by datastore 'Base Test'. [Base Test]VMTEST01/VMTEST01_2.vmdk Originally I had the VMFS datastore formatted with 1 meg blocks which was the cause of this problem since the largest disk allowed would be 256 gigs. But I deleted the data store and then reformatted with 4 megs blocks. I've also tried using virtual compatibility mode for the raw device but it still fails. Does anyone have any suggestions? I've been waiting for a little over a week for VMWare, but that's fine because I'm not yet a paying customer. I'm still in the eval phase.

    Read the article

  • DNS failover in a two datacenter scenario

    - by wanson
    I'm trying to implement a low-cost solution for website high availability. I'm looking for the downsides of the following scenario: I have two servers with the same configuration, content, mysql replication (dual-master). They are in different datacenters - let's call them serverA and serverB. Users use serverA - serverB is more like a backup. Now, I want to use DNS failover, to switch users from serverA to serverB when serverA goes down. My idea is that I setup DNS servers (bind/powerdns) on serverA and serverB - let's call them ns1.website.com and ns2.website.com (assuming I own website.com). Then I configure my domain to use them as its nameservers. Both DNS servers will return serverA IP as my website's IP. If serverA goes down I can (either manually or automatically from serverB) change configuration of serverB's DNS, to return IP of serverB as website's IP. Of course the TTL will be low, as it's supposed to be in DNS failovers. I know that it may take some time to switch to serverB (DNS ttl, time to detect serverA failure, serverB DNS reconfiguration etc), and that some small part of users won't use serverB anyway. And I'm OK with that. But what are other downsides of such an approach? An alternative scenario is that ns1.website.com will return serverA IP as website's IP, and ns2.website.com will return serverB IP as website's IP. But AFAIK clients not always use primary nameserver and sometimes would use secondary one. So some small part of users would use serverB instead of serverA which is not quite what I'd like. Can you confirm that DNS clients behave like that and can you tell what percentage of clients would possibly use serverB instead of serverA (statistically)? This one also has the downside that when serverA goes back up, it will be automatically used as website's primary server, which is also a bad situation (cold cache, mysql replication could fail in the meantime etc). So I'm adding it only as a theoretical alternative. I was thinking about using some professional DNS failover companies but they charge for the number of DNS requests and the fees are very high (why?)

    Read the article

  • SBD killing both cluster nodes when there are even small SAN network problems

    - by Wieslaw Herr
    I am having problems with stonith SBD in a openais-based cluster. Some background: The active/passive cluster has two nodes, node1 and node2. They are configured to provide an NFS service to users. To avoid problems with split-brain, they are both configured to use SBD. SBD is using two 1MB disks available to the hosts via an multipath fibre-channel network. The problems start if something happens with the SAN network. For example, today one of the brocade switches got rebooted and both nodes lost 2 out of 4 paths to each disks, which resulted in both nodes committing suicide and rebooting. This, of course, was highly undesirable because a) there were paths left b) even if the switch would be out for 10-20 seconds a reboot cycle of both nodes would take 5-10 minutes and all NFS-locks would be lost. I tried increasing the SBD timeout values (to 10sec+ values, dump attached at the end), however a "WARN: Latency: No liveness for 4 s exceeds threshold of 3 s" hints that something isn't working as I would it expect to. Here is what I would like to know: a) Is SBD working as it should killing nodes when 2 paths are available? b) If not, is the multipath.conf file attached correct? The storage controller we use is an IBM SVC (IBM 2145), should there be any specific configuration for it? (as in multipath.conf.defaults) c) How should I go about increasing the timeouts in SBD attachements: Multipath.conf and sbd dump (http://hpaste.org/69537)

    Read the article

  • Multi-WAN bonding across different media

    - by Tom O'Connor
    I've recently been thinking again about a product that Viprinet provide, basically they've got a pair of routers, one that lives in a datacentre, Their VPN Multichannel Hub and the on-site hardware, their VPN multichannel routers They've also got a bunch of interface cards (like HWICs) for 3G, UMTS, Ethernet, ADSL and ISDN adapters. Their main spiel seems to be bonding across different media. It's something that I'd really like to use for a couple of projects, but their pricing is really quite extreme, the hub is about 1-2k, the routers are 2-6k, and the interface modules are 200-600 each. So, what I'd like to know is, is it possible with a couple of stock Cisco routers, 28xx or 18xx series, to do something similar, and basically connect a bunch of different WAN ports, but have it all presented neatly as one channel back to the internet, with seamless (or nearly) failover if one of the WAN interfaces should fail. Basically, If i got 3x 3G to ethernet modems, and each on a different network, I'd like to be able to loadbalance/bond across all of them, without having to pay Viprinet for the privilege. Does anyone know how I'd go about configuring something for myself, based around standard protocols (or vendor specific ones), but without actually having to buy the Viprinet hardware?

    Read the article

< Previous Page | 187 188 189 190 191 192 193 194 195 196 197 198  | Next Page >