Search Results

Search found 23808 results on 953 pages for 'call centre'.

Page 188/953 | < Previous Page | 184 185 186 187 188 189 190 191 192 193 194 195  | Next Page >

  • Problem with SLATEC routine usage with gfortran

    - by user39461
    I am trying to compute the Bessel function of the second kind (Bessel_y) using the SLATEC's Amos library available on Netlib. Here is the SLATEC code I use. Below I have pasted my test program that calls SLATEC routine CBESY. PROGRAM BESSELTEST IMPLICIT NONE REAL:: FNU INTEGER, PARAMETER :: N = 2, KODE = 1 COMPLEX,ALLOCATABLE :: CWRK (:), CY (:) COMPLEX:: Z, ci INTEGER :: NZ, IERR ALLOCATE(CWRK(N), CY(N)) ci = cmplx (0.0, 1.0) FNU = 0.0e0 Z = CMPLX(0.3e0, 0.4e0) CALL CBESY(Z, FNU, KODE, N, CY, NZ, CWRK, IERR) WRITE(*,*) 'CY: ', CY WRITE(*,*) 'IERR: ', IERR STOP END PROGRAM And here is the output of the above program: CY: ( 5.78591091E-39, 5.80327020E-39) ( 0.0000000 , 0.0000000 ) IERR: 4 Ierr = 4 meaning there is some problem with the input itself. To be precise, the IERR = 4 means the following as per the header info in CBESY.f file: ! IERR=4, CABS(Z) OR FNU+N-1 TOO LARGE - NO COMPUTA- ! TION BECAUSE OF COMPLETE LOSSES OF SIGNIFI- ! CANCE BY ARGUMENT REDUCTION Clearly, CABS(Z) (which is 0.50) or FNU + N - 1 (which is 1.0) are not too large but still the routine CBESY throws the error message number 4 as above. The CY array should have following values for the argument given in above code: CY(1) = -0.4983 + 0.6700i CY(2) = -1.0149 + 0.9485i These values are computed using Matlab. I can't figure out what's the problem when I call CBESY from SLATEC library. Any clues? Much thanks for the suggestions/help. PS: if it is of any help, I used gfortran to compile, link and then create the SLATEC library file ( the .a file ) which I keep in the same directory as my test program above. shell command to execute above code: gfortran -c BesselTest.f95 gfortran -o a *.o libslatec.a a GD.

    Read the article

  • How to make exe of autohotkey scripts?

    - by Jitendra vyas
    see example http://antun.vkrgnf.com/wp-content/uploads/2008/03/jttss02_insertmodule.png download this application then see what i want http://antun.vkrgnf.com/?page_id=2 for example if i have a text like this Before you make that important call (or after a configuration change) be sure to check your connection and volume with Skypes Test Call (echo 123) It takes less than a minute to complete. and if i select whole text via mouse or keyboard then something bar like this example tool which should have a button for different HTML tag to make content to html in any browser or software. want to custom Text bar like this. but independent like this

    Read the article

  • New Fusion CRM Webinars for Partners dates and subjects announced

    - by Richard Lefebvre
    New Fusion CRM Weekly webinars dates and subjects have been announced! Visit our microsite to find out the sessions to come and mark them in your agenda. The next session will take place Monday April the 2nd at 3pm GMT / 4pm CET and will address the Fusion CRM Sales Planning  In order to check the complete agenda and see login-details, please visit our dedicated microsite. How to join the dedicated microsite: Click on http://isdportal.oracle.com/isd_html/sf.htm Enter your Email Address in the corresponding field Enter fusion_crm in the “Access URL/Page Token” field Agenda: The list of sessions is published and will be regularly updated in the microsite. Duration: Each session lasts up to 60 minutes Webex: The respective webinar link and session ID are published in the microsite Audio:  The audio call details (telephone numbers by country, call number and password) is indicated in the microsite Slides: For your convenience, a pdf copy of each presentation will be stored in the microsite’s document section. We hope that this series of webcasts will be instrumental to your way of Fusion CRM business success!  For further information please contact me at [email protected]

    Read the article

  • Metro: Understanding the default.js File

    - by Stephen.Walther
    The goal of this blog entry is to describe — in painful detail — the contents of the default.js file in a Metro style application written with JavaScript. When you use Visual Studio to create a new Metro application then you get a default.js file automatically. The file is located in a folder named \js\default.js. The default.js file kicks off all of your custom JavaScript code. It is the main entry point to a Metro application. The default contents of the default.js file are included below: // For an introduction to the Blank template, see the following documentation: // http://go.microsoft.com/fwlink/?LinkId=232509 (function () { "use strict"; var app = WinJS.Application; app.onactivated = function (eventObject) { if (eventObject.detail.kind === Windows.ApplicationModel.Activation.ActivationKind.launch) { if (eventObject.detail.previousExecutionState !== Windows.ApplicationModel.Activation.ApplicationExecutionState.terminated) { // TODO: This application has been newly launched. Initialize // your application here. } else { // TODO: This application has been reactivated from suspension. // Restore application state here. } WinJS.UI.processAll(); } }; app.oncheckpoint = function (eventObject) { // TODO: This application is about to be suspended. Save any state // that needs to persist across suspensions here. You might use the // WinJS.Application.sessionState object, which is automatically // saved and restored across suspension. If you need to complete an // asynchronous operation before your application is suspended, call // eventObject.setPromise(). }; app.start(); })(); There are several mysterious things happening in this file. The purpose of this blog entry is to dispel this mystery. Understanding the Module Pattern The first thing that you should notice about the default.js file is that the entire contents of this file are enclosed within a self-executing JavaScript function: (function () { ... })(); Metro applications written with JavaScript use something called the module pattern. The module pattern is a common pattern used in JavaScript applications to create private variables, objects, and methods. Anything that you create within the module is encapsulated within the module. Enclosing all of your custom code within a module prevents you from stomping on code from other libraries accidently. Your application might reference several JavaScript libraries and the JavaScript libraries might have variables, objects, or methods with the same names. By encapsulating your code in a module, you avoid overwriting variables, objects, or methods in the other libraries accidently. Enabling Strict Mode with “use strict” The first statement within the default.js module enables JavaScript strict mode: 'use strict'; Strict mode is a new feature of ECMAScript 5 (the latest standard for JavaScript) which enables you to make JavaScript more strict. For example, when strict mode is enabled, you cannot declare variables without using the var keyword. The following statement would result in an exception: hello = "world!"; When strict mode is enabled, this statement throws a ReferenceError. When strict mode is not enabled, a global variable is created which, most likely, is not what you want to happen. I’d rather get the exception instead of the unwanted global variable. The full specification for strict mode is contained in the ECMAScript 5 specification (look at Annex C): http://www.ecma-international.org/publications/files/ECMA-ST/ECMA-262.pdf Aliasing the WinJS.Application Object The next line of code in the default.js file is used to alias the WinJS.Application object: var app = WinJS.Application; This line of code enables you to use a short-hand syntax when referring to the WinJS.Application object: for example,  app.onactivated instead of WinJS.Application.onactivated. The WinJS.Application object  represents your running Metro application. Handling Application Events The default.js file contains an event handler for the WinJS.Application activated event: app.onactivated = function (eventObject) { if (eventObject.detail.kind === Windows.ApplicationModel.Activation.ActivationKind.launch) { if (eventObject.detail.previousExecutionState !== Windows.ApplicationModel.Activation.ApplicationExecutionState.terminated) { // TODO: This application has been newly launched. Initialize // your application here. } else { // TODO: This application has been reactivated from suspension. // Restore application state here. } WinJS.UI.processAll(); } }; This WinJS.Application class supports the following events: · loaded – Happens after browser DOMContentLoaded event. After this event, the DOM is ready and you can access elements in a page. This event is raised before external images have been loaded. · activated – Triggered by the Windows.UI.WebUI.WebUIApplication activated event. After this event, the WinRT is ready. · ready – Happens after both loaded and activated events. · unloaded – Happens before application is unloaded. The following default.js file has been modified to capture each of these events and write a message to the Visual Studio JavaScript Console window: (function () { "use strict"; var app = WinJS.Application; WinJS.Application.onloaded = function (e) { console.log("Loaded"); }; WinJS.Application.onactivated = function (e) { console.log("Activated"); }; WinJS.Application.onready = function (e) { console.log("Ready"); } WinJS.Application.onunload = function (e) { console.log("Unload"); } app.start(); })(); When you execute the code above, a message is written to the Visual Studio JavaScript Console window when each event occurs with the exception of the Unload event (presumably because the console is not attached when that event is raised).   Handling Different Activation Contexts The code for the activated handler in the default.js file looks like this: app.onactivated = function (eventObject) { if (eventObject.detail.kind === Windows.ApplicationModel.Activation.ActivationKind.launch) { if (eventObject.detail.previousExecutionState !== Windows.ApplicationModel.Activation.ApplicationExecutionState.terminated) { // TODO: This application has been newly launched. Initialize // your application here. } else { // TODO: This application has been reactivated from suspension. // Restore application state here. } WinJS.UI.processAll(); } }; Notice that the code contains a conditional which checks the Kind of the event (the value of e.detail.kind). The startup code is executed only when the activated event is triggered by a Launch event, The ActivationKind enumeration has the following values: · launch · search · shareTarget · file · protocol · fileOpenPicker · fileSavePicker · cacheFileUpdater · contactPicker · device · printTaskSettings · cameraSettings Metro style applications can be activated in different contexts. For example, a camera application can be activated when modifying camera settings. In that case, the ActivationKind would be CameraSettings. Because we want to execute our JavaScript code when our application first launches, we verify that the kind of the activation event is an ActivationKind.Launch event. There is a second conditional within the activated event handler which checks whether an application is being newly launched or whether the application is being resumed from a suspended state. When running a Metro application with Visual Studio, you can use Visual Studio to simulate different application execution states by taking advantage of the Debug toolbar and the new Debug Location toolbar.  Handling the checkpoint Event The default.js file also includes an event handler for the WinJS.Application checkpoint event: app.oncheckpoint = function (eventObject) { // TODO: This application is about to be suspended. Save any state // that needs to persist across suspensions here. You might use the // WinJS.Application.sessionState object, which is automatically // saved and restored across suspension. If you need to complete an // asynchronous operation before your application is suspended, call // eventObject.setPromise(). }; The checkpoint event is raised when your Metro application goes into a suspended state. The idea is that you can save your application data when your application is suspended and reload your application data when your application resumes. Starting the Application The final statement in the default.js file is the statement that gets everything going: app.start(); Events are queued up in a JavaScript array named eventQueue . Until you call the start() method, the events in the queue are not processed. If you don’t call the start() method then the Loaded, Activated, Ready, and Unloaded events are never raised. Summary The goal of this blog entry was to describe the contents of the default.js file which is the JavaScript file which you use to kick off your custom code in a Windows Metro style application written with JavaScript. In this blog entry, I discussed the module pattern, JavaScript strict mode, handling first chance exceptions, WinJS Application events, and activation contexts.

    Read the article

  • How to remap a NERDTree shortcut in VIM

    - by btelles
    Hi There, I use the Dvorak keyboard layout with VIM, and the 't' key is the 'up' motion when editing a regular file. The problem is that NERDTree remaps 't' to open files in a new tab. How can I undo that mapping and use 't' for the up motion in NERDTree? Here are the relevant lines from my vimrc file and from the NERDTree plugin. My .vimrc: no t k NERDTree plugin file: exec "nnoremap <silent> <buffer> ". g:NERDTreeMapOpenInTab ." :call <SID>openInNewTab(0)<cr>" call s:initVariable("g:NERDTreeMapOpenInTab", "t") let @h=@h."\" ". g:NERDTreeMapOpenInTab.": open in new tab\n"

    Read the article

  • VS 2010 IDE Features in a nutshell

    - by Rajesh Pillai
    Going through a VS 2010 IDE Features.  We will explore each feature in subsequent posts.  The post are documented as being reviewed by me.   Breakpoint Labeling Breakpoint Searching Breakpoint Import/Export Dynamic Data Tooling WPF Tree Visualizer Call Hierarchy Improved WPF Tooling Historical Debugging Mini-Dump Debugging Quick Search Better Multi-Monitor Support Highlight References Parallel Stacks Window Parallel Tasks Window Document Map Margin Generate from Usage Concurrency Profiler Inline Call Tree Extensible Test Runner MVC Tooling Web Deploy JQuery IntelliSense SharePoint Tooling HTML Snippets Web.config Transformation ClickOnce Enhancements for MS Office     VS is an editor as well as a platform for development and this is only more true with VS 2010.  As an editor there is improved forcus on writing code, understanding code, navigating and publishing code.   VS Shell has been completely rewritten using WPF extending huge benefits.  The start page has been rewritten using XAML, so it is easy to customize.   Support new support for Silverlight, MFC, F# , Azure and extended support for Office 2010, Sharepoint.   Has a good Extension Manager as well.   Enjoy Coding !!!

    Read the article

  • Adeos's role w.r.t Linux

    - by Anisha Kaul
    The event pipeline The fundamental Adeos structure one must keep in mind is the chain of client domains asking for event control. A domain is a kernelbased software component which can ask the Adeos layer to be notified of: · Every incoming external interrupt, or autogenerated virtual interrupt; · Every system call issued by Linux applications, · Other system events triggered by the kernel code (e.g. Linux task switching, signal notification, Linux task exits etc.). From: Life with Adeos: http://www.xenomai.org/documentation/xenomai-2.4/pdf/Life-with-Adeos-rev-B.pdf Question: Adeos is supposed to be between the hardware and the Linux kernel, I can understand about Adeos telling the Linux about hardware interrupts but Why should Adeos know about the "system call" issued by Linux?

    Read the article

  • Is it possible to rate-limit an scp/sftp/rsync/etc transfer from the command-line? ie, manual QoS on

    - by warren
    Specifically, I am looking to rate-limit an scp or sftp session (or other arbitrary network call) in the call itself. For example, let's say I want to copy 100MB to one server, and 1GB to another. I'd like to be able to run both of these at the same time, but maintain a QoS for "normal" computer usage - somewhat similar to how you can rate-limit bittorrent. Is there a way to do this without touching the networking hardware? I'm envisioning something akin to: magic-qos-tool 'scp file user@host:/path/to/file' Or.. scp -rate 40kbps file user@host:/path/to/file

    Read the article

  • Skype keypad tones

    - by Don
    Hi, When I push a number on the Skype keypad (or use the number keys on the keyboard) no tone is emitted. This happens both when dialling a number and if I push a key during a call. This makes it impossible for me to use Skype with automated telephone systems that require you to use the keypad to enter data or choose between various options. I spoke to somebody who works in a call centre about this and they indicated that somebody had mentioned that it's possible to disable (DTMF) tones in Skype. I've looked through all the Skype options and can't find any way to enable/disable DTMF tones. If somebody knows how I can do this, or has another suggestion for fixing the problem, please let me know. I'm using version 4.2.0.152 of Skype. Thanks, Don

    Read the article

  • Rhythmbox 2.99.1 crashes when playing any song on Ubuntu 13.10

    - by John H
    Yesterday rhythmbox was running smoothly but today it crashes only a few seconds after I hit the play button, regardless of track. I've tried disabling plugins, re-installing rhythmbox via synaptics, clearing the library and the rhythmdb.xml-file and just adding one album. Still, it crashes. If I run the rhythmbox from the command line i get the following before I have to force quit: :~$ rhythmbox Failed to create secure directory (/run/user/1000/pulse): Permission denied Killed :~$ However, if i run rhythmbox via the command line as superuser it does work. But i get the following errors: sudo rhythmbox (rhythmbox:8335): Gtk-WARNING **: Failed to register client: GDBus.Error:org.freedesktop.DBus.Error.ServiceUnknown: The name org.gnome.SessionManager was not provided by any .service files (rhythmbox:8335): IBUS-WARNING **: The owner of /home/john/.config/ibus/bus is not root! (rhythmbox:8335): Rhythmbox-WARNING **: Unable to grab media player keys: GDBus.Error:org.freedesktop.DBus.Error.ServiceUnknown: The name org.gnome.SettingsDaemon was not provided by any .service files Traceback (most recent call last): File "/usr/lib/rhythmbox/plugins/rb/Loader.py", line 47, in _contents_cb (ok, contents, etag) = file.load_contents_finish(result) gi._glib.GError: Operation not supported Traceback (most recent call last): File "/usr/lib/python2.7/dist-packages/gi/overrides/GLib.py", line 634, in return (lambda data: callback(*data), user_data) […] I'm running rhythmbox on a Lenovo e335 thikpad edge. I hope I've supplied enough information. Cheers -John

    Read the article

  • Subscript out of range error in VBScript script

    - by user3912
    I'm trying to move my entire User folder in Windows Vista to a non-system partition. To do so with a minimum hassle I'm following the directions provided at Ben's Blog, specifically the VBScript he provides. However executing the script throws up an error which I can't resolve myself. Here's the VBScript code followed by the text file it works from, and finally my error message. How do I correct the problem? VBScript Code: '# Perform dir /a c:\users > c:\dir.txt '# place this script file in c:\ too '# double click to run it '# run resulting script.bat from recovery mode repprefix = " Directory of..." ' Modify to your language sourcedrive = "C:\" targetdrive = "D:\" altsourcedrive = "C:\" 'leave same as target drive unless otherwise indicated alttargetdrive = "E:\" 'leave same as target drive unless otherwise indicated inname = "dir.txt" outname = "script.bat" userroot = "Users" set fso = CreateObject("Scripting.FileSystemObject") ' construct batch commands for saving rights, then link, the recreating rights Function GetCommand(curroot, line, typ, keyword) ' first need to get source and target pos = Instr(line, keyword) + Len(keyword) tuple = Trim(Mid(line, pos)) arr = Split(tuple, "[") oldtarget = Replace(arr(1), "]", "") oldlink = curroot & "\" & Trim(arr(0)) ' need to determine if we are pointing back to old disk newlink = replace(oldlink, sourcedrive, targetdrive) if(Instr(oldtarget, sourcedrive & userroot)) then newtarget = Replace(oldtarget, sourcedrive, targetdrive) else newtarget = oldtarget ' still pointing to original target end if ' comment out = "echo " & newlink & " --- " & newtarget & vbCrLf ' save permissions out = out & "icacls """ & replace(oldlink, sourcedrive, altsourcedrive) & """ /L /save " & altsourcedrive & "permissions.txt" & vbCrLf ' create link newlink = replace(newlink, targetdrive, alttargetdrive) if typ = "junction" then out = out & "mklink /j """ & newlink & """ """ & newtarget & """" & vbCrLf else ' typ = "symlink" out = out & "mklink /d """ & newlink & """ """ & newtarget & """" & vbCrLf end if 'set hidden attribute out = out & "attrib +h """ & newlink & """ /L" & vbCrLf ' apply permissions shortlink = Left(newlink, InstrRev(newlink, "\") - 1) 'icacls works strangely - non-orthogonal for restore out = out & "icacls """ & shortlink & """ /L /restore " & altsourcedrive & "permissions.txt" & vbCrLf GetCommand = out & vbCrLf End Function Sub WriteToFile(file, text) ForWriting = 2 Create = true set outfile = fso.OpenTextFile(file, ForWriting, Create) Call outfile.Write(text) Call outfile.Close() End Sub outtext = "ROBOCOPY " & altsourcedrive & userroot & " " & alttargetdrive & userroot & " /E /COPYALL /XJ" & vbCrLf & vbCrLf set intext = fso.OpenTextFile(inname) while not intext.AtEndOfStream line = intext.ReadLine() if Instr(line, repprefix) then curroot = Replace(line, repprefix, "") elseif Instr(line, juncname) then outtext = outtext & GetCommand(curroot, line, "junction", juncname) elseif Instr(line, linkname) then outtext = outtext & GetCommand(curroot, line, "symlink", linkname) end if Wend outtext = outtext & "icacls " & altsourcedrive & userroot & " /L /save " & altsourcedrive & "permissions.txt" & vbCrLf outtext = outtext & "ren " & altsourcedrive & userroot & " _" & userroot & vbCrLf outtext = outtext & "mklink /j " & altsourcedrive & userroot & " " & targetdrive & userroot & vbCrLf outtext = outtext & "icacls " & altsourcedrive & " /L /restore " & altsourcedrive & "permissions.txt" Call intext.Close() Call WriteToFile(outname, outtext) MsgBox("Done writing to " & outname) dir.txt: Volume in drive C is ACER Volume Serial Number is 08D7-C0CC Directory of c:\users 07/16/2009 12:29 PM {DIR} . 07/16/2009 12:29 PM {DIR} .. 11/02/2006 09:02 AM {SYMLINKD} All Users [C:\ProgramData] 11/02/2006 09:02 AM {DIR} Default 11/02/2006 09:02 AM {JUNCTION} Default User [C:\Users\Default] 08/21/2008 08:37 AM 174 desktop.ini 11/02/2006 08:50 AM {DIR} Public 07/19/2009 08:54 PM {DIR} Steve 1 File(s) 174 bytes 7 Dir(s) 5,679,947,776 bytes free Error Message: Windows Script Host Script: C:\user location.vbs Line: 25 Char: 2 Error: Subscript out of range: '[number: 1]' Code: 800A0009 Source: Microsoft VBScript runtime error (In the VBScript script that I'm using on my system, I believe that 'Line 25' corresponds to the line beginning with oldtarget = Replace(arr(1), "]", "").

    Read the article

  • Subscript out of range error in VBScript script

    - by SteveW
    I'm trying to move my entire User folder in Windows Vista to a non-system partition. To do so with a minimum hassle I'm following the directions provided at Ben's Blog, specifically the VBScript he provides. However executing the script throws up an error which I can't resolve myself. Here's the VBScript code followed by the text file it works from, and finally my error message. How do I correct the problem? VBScript Code: '# Perform dir /a c:\users > c:\dir.txt '# place this script file in c:\ too '# double click to run it '# run resulting script.bat from recovery mode repprefix = " Directory of..." ' Modify to your language sourcedrive = "C:\" targetdrive = "D:\" altsourcedrive = "C:\" 'leave same as target drive unless otherwise indicated alttargetdrive = "E:\" 'leave same as target drive unless otherwise indicated inname = "dir.txt" outname = "script.bat" userroot = "Users" set fso = CreateObject("Scripting.FileSystemObject") ' construct batch commands for saving rights, then link, the recreating rights Function GetCommand(curroot, line, typ, keyword) ' first need to get source and target pos = Instr(line, keyword) + Len(keyword) tuple = Trim(Mid(line, pos)) arr = Split(tuple, "[") oldtarget = Replace(arr(1), "]", "") oldlink = curroot & "\" & Trim(arr(0)) ' need to determine if we are pointing back to old disk newlink = replace(oldlink, sourcedrive, targetdrive) if(Instr(oldtarget, sourcedrive & userroot)) then newtarget = Replace(oldtarget, sourcedrive, targetdrive) else newtarget = oldtarget ' still pointing to original target end if ' comment out = "echo " & newlink & " --- " & newtarget & vbCrLf ' save permissions out = out & "icacls """ & replace(oldlink, sourcedrive, altsourcedrive) & """ /L /save " & altsourcedrive & "permissions.txt" & vbCrLf ' create link newlink = replace(newlink, targetdrive, alttargetdrive) if typ = "junction" then out = out & "mklink /j """ & newlink & """ """ & newtarget & """" & vbCrLf else ' typ = "symlink" out = out & "mklink /d """ & newlink & """ """ & newtarget & """" & vbCrLf end if 'set hidden attribute out = out & "attrib +h """ & newlink & """ /L" & vbCrLf ' apply permissions shortlink = Left(newlink, InstrRev(newlink, "\") - 1) 'icacls works strangely - non-orthogonal for restore out = out & "icacls """ & shortlink & """ /L /restore " & altsourcedrive & "permissions.txt" & vbCrLf GetCommand = out & vbCrLf End Function Sub WriteToFile(file, text) ForWriting = 2 Create = true set outfile = fso.OpenTextFile(file, ForWriting, Create) Call outfile.Write(text) Call outfile.Close() End Sub outtext = "ROBOCOPY " & altsourcedrive & userroot & " " & alttargetdrive & userroot & " /E /COPYALL /XJ" & vbCrLf & vbCrLf set intext = fso.OpenTextFile(inname) while not intext.AtEndOfStream line = intext.ReadLine() if Instr(line, repprefix) then curroot = Replace(line, repprefix, "") elseif Instr(line, juncname) then outtext = outtext & GetCommand(curroot, line, "junction", juncname) elseif Instr(line, linkname) then outtext = outtext & GetCommand(curroot, line, "symlink", linkname) end if Wend outtext = outtext & "icacls " & altsourcedrive & userroot & " /L /save " & altsourcedrive & "permissions.txt" & vbCrLf outtext = outtext & "ren " & altsourcedrive & userroot & " _" & userroot & vbCrLf outtext = outtext & "mklink /j " & altsourcedrive & userroot & " " & targetdrive & userroot & vbCrLf outtext = outtext & "icacls " & altsourcedrive & " /L /restore " & altsourcedrive & "permissions.txt" Call intext.Close() Call WriteToFile(outname, outtext) MsgBox("Done writing to " & outname) dir.txt: Volume in drive C is ACER Volume Serial Number is 08D7-C0CC Directory of c:\users 07/16/2009 12:29 PM {DIR} . 07/16/2009 12:29 PM {DIR} .. 11/02/2006 09:02 AM {SYMLINKD} All Users [C:\ProgramData] 11/02/2006 09:02 AM {DIR} Default 11/02/2006 09:02 AM {JUNCTION} Default User [C:\Users\Default] 08/21/2008 08:37 AM 174 desktop.ini 11/02/2006 08:50 AM {DIR} Public 07/19/2009 08:54 PM {DIR} Steve 1 File(s) 174 bytes 7 Dir(s) 5,679,947,776 bytes free Error Message: Windows Script Host Script: C:\user location.vbs Line: 25 Char: 2 Error: Subscript out of range: '[number: 1]' Code: 800A0009 Source: Microsoft VBScript runtime error (In the VBScript script that I'm using on my system, I believe that 'Line 25' corresponds to the line beginning with oldtarget = Replace(arr(1), "]", "").

    Read the article

  • Real or False Recovery? Economic 'tea-leaves'

    - by [email protected]
    "Information-technology is allowing the city's economy to speak to us in lots of different ways," Mr. Egan said. "We just need to find new ways of listening." Source: "New Way to Read Economy" WSJ_ARTICLE  April 8th, Carli Tuna, Blog by ARC's Steve Banker Apr 12, 2010 Alan Greenspan used cardboard box purchases and other 'source-commodity' indicators. The Carli Tuna WSJ article said that truck diesel fuel sales are a reliable indicator. What factor do you and your company use as future forward indicators? .. is it quotes, perhaps calls into the call center or sales activity?  Is your business moving to the internet and your supply chain driven by your iStore?  How do your distributors, retailers and supply chain partners provide the 'side-line' signals to you to either ramp up or contract production? With competition being only one click away, organizations need to know with higher degrees of certainty, what the econmic 'tea-leaves' are telling us and how firms need to react with production and shipping forecasts.  Firms using the latest forecasting and supply chain analytical (Bus.Intelligence) tools and technologies appear to be leading their markets "Had we been aware of that data in 2008," Mr. Leamer said, "we would have made a different call." .        

    Read the article

  • PHP Aspect Oriented Design

    - by Devin Dixon
    This is a continuation of this Code Review question. What was taken away from that post, and other aspect oriented design is it is hard to debug. To counter that, I implemented the ability to turn tracing of the design patterns on. Turning trace on works like: //This can be added anywhere in the code Run::setAdapterTrace(true); Run::setFilterTrace(true); Run::setObserverTrace(true); //Execute the functon echo Run::goForARun(8); In the actual log with the trace turned on, it outputs like so: adapter 2012-02-12 21:46:19 {"type":"closure","object":"static","call_class":"\/public_html\/examples\/design\/ClosureDesigns.php","class":"Run","method":"goForARun","call_method":"goForARun","trace":"Run::goForARun","start_line":68,"end_line":70} filter 2012-02-12 22:05:15 {"type":"closure","event":"return","object":"static","class":"run_filter","method":"\/home\/prodigyview\/public_html\/examples\/design\/ClosureDesigns.php","trace":"Run::goForARun","start_line":51,"end_line":58} observer 2012-02-12 22:05:15 {"type":"closure","object":"static","class":"run_observer","method":"\/home\/prodigyview\/public_html\/public\/examples\/design\/ClosureDesigns.php","trace":"Run::goForARun","start_line":61,"end_line":63} When the information is broken down, the data translates to: Called by an adapter or filter or observer The function called was a closure The location of the closure Class:method the adapter was implemented on The Trace of where the method was called from Start Line and End Line The code has been proven to work in production environments and features various examples of to implement, so the proof of concept is there. It is not DI and accomplishes things that DI cannot. I wouldn't call the code boilerplate but I would call it bloated. In summary, the weaknesses are bloated code and a learning curve in exchange for aspect oriented functionality. Beyond the normal fear of something new and different, what are other weakness in this implementation of aspect oriented design, if any? PS: More examples of AOP here: https://github.com/ProdigyView/ProdigyView/tree/master/examples/design

    Read the article

  • radvd is not assigning prefix

    - by Samik
    I'm currently trying to setup IPv6 address auto-configuration with router advertisement daemon (radvd) on a virtual machine running CentOS 6.5. But the eth0 interface is not obtaining that prefix. I've obtained the ULA prefix from here. Contents of /etc/sysctl.conf # Kernel sysctl configuration file for Red Hat Linux # # For binary values, 0 is disabled, 1 is enabled. See sysctl(8) and # sysctl.conf(5) for more details. # Controls IP packet forwarding net.ipv4.ip_forward = 0 net.ipv6.conf.all.forwarding = 1 # Controls source route verification net.ipv4.conf.default.rp_filter = 1 # Do not accept source routing net.ipv4.conf.default.accept_source_route = 0 # Controls the System Request debugging functionality of the kernel kernel.sysrq = 0 # Controls whether core dumps will append the PID to the core filename. # Useful for debugging multi-threaded applications. kernel.core_uses_pid = 1 # Controls the use of TCP syncookies net.ipv4.tcp_syncookies = 1 # Disable netfilter on bridges. net.bridge.bridge-nf-call-ip6tables = 0 net.bridge.bridge-nf-call-iptables = 0 net.bridge.bridge-nf-call-arptables = 0 # Controls the default maxmimum size of a mesage queue kernel.msgmnb = 65536 # Controls the maximum size of a message, in bytes kernel.msgmax = 65536 # Controls the maximum shared segment size, in bytes kernel.shmmax = 68719476736 # Controls the maximum number of shared memory segments, in pages kernel.shmall = 4294967296 Contents of /etc/radvd.conf # NOTE: there is no such thing as a working "by-default" configuration file. # At least the prefix needs to be specified. Please consult the radvd.conf(5) # man page and/or /usr/share/doc/radvd-*/radvd.conf.example for help. # # interface eth0 { AdvSendAdvert on; MinRtrAdvInterval 3; MaxRtrAdvInterval 10; AdvDefaultPreference low; AdvHomeAgentFlag off; prefix fd8a:8d9d:808f:1::/64 { AdvOnLink on; AdvAutonomous on; AdvRouterAddr on; }; }; Contents of /etc/sysconfig/network-scripts/ifcfg-eth0 DEVICE=eth0 HWADDR=52:54:00:74:d7:46 TYPE=Ethernet UUID=af5db1cb-e809-4098-be1a-5a74dbb767b1 ONBOOT=yes NM_CONTROLLED=no BOOTPROTO=dhcp IPV6INIT=yes IPV6_AUTOCONF=yes I've also enabled radvd at startup through chkconfig. Though I noticed that radvd is starting after interfaces are brought up. I've tried restarting the network service afterwards but still I get the following link-local address only #ip -6 addr show 1: lo: mtu 16436 inet6 ::1/128 scope host valid_lft forever preferred_lft forever 2: eth0: mtu 1500 qlen 1000 inet6 fe80::5054:ff:fe74:d746/64 scope link valid_lft forever preferred_lft forever Edit: Based on the answer given by Sander Steffann I still need clarification on some points but I'm posting here what worked. Contents of /etc/sysconfig/network NETWORKING=yes HOSTNAME=syslog-ng-server NETWORKING_IPV6=yes IPV6FORWARDING=yes Contents of /etc/sysconfig/network-scripts/ifcfg-eth0 DEVICE=eth0 HWADDR=52:54:00:74:d7:46 TYPE=Ethernet UUID=af5db1cb-e809-4098-be1a-5a74dbb767b1 ONBOOT=yes NM_CONTROLLED=no BOOTPROTO=dhcp IPV6INIT=yes IPV6_AUTOCONF=yes IPV6FORWARDING=no Removed following line from /etc/sysctl.conf net.ipv6.conf.all.forwarding = 1 Contents of /etc/radvd.conf is as previous.

    Read the article

  • New Oracle Tutor Class: Create Procedures and Support Documents

    - by [email protected]
    Offered by Oracle University Course Code D66797GC10 July 14-16, 2010 in Chicago, IL This three day Instructor Led class is only US$ 2,250 Oracle® Tutor provides organizations with a powerful pair of applications to develop, deploy, and maintain employee business process documentation. Tutor includes a repository of prewritten process, procedure, and support documents that can be readily modified to reflect your company's unique business processes. The result is a set of job-role specific desk manuals that are easy to update and deploy online. Use Tutor to create content to: Implement new business applications Document for any regulatory compliance initiative Turn every desk into a self service reference center Increase employee productivity The primary challenge for companies faced with documenting policies, processes, and procedures is to realize that they can do this documentation in-house, with existing resources, using Oracle Tutor. Process documentation is a critical success component when implementing or upgrading to a new business application and for supporting corporate governance or other regulatory compliance initiatives. There are over 1000 Oracle Tutor customers worldwide that have used Tutor to create, distribute, and maintain their business procedures. This is easily accomplished because of Tutor's: Ease of use by those who have to write procedures (Microsoft Word based authoring) Ease of company-wide implementation (complex document management activities are centralized) Ease of use by workers who have to follow the procedures (play script format) Ease of access by remote workers (web-enabled) This course is an introduction to the Oracle Tutor suite of products. It focuses on the process documentation feature set of the Tutor applications. Participants will learn about writing procedures and maintaining these particular process document types, all using the Tutor method. Audience Business Analysts End Users Functional Implementer Project Manager Sales Consultants Security Compliance Auditors User Adoption Consultants Prerequisites No Prerequisite Courses strong working knowledge of MS Windows strong working knowledge of MS Word (2007) Objectives • Provide your organization with the next steps to implement the Tutor procedure writing method and system in your organization • Use the Tutor Author application to write employee focused process documents (procedures, instructions, references, process maps) • Use the Tutor Publisher application to create impact analysis reports, Employee Desk Manuals, and Owner Manuals Web site on OU Link to a PDF of the class summary Oracle University Training Centre - Chicago Emily Chorba Product Manager for Oracle Tutor

    Read the article

  • Skype Optimization - Port Forwarding on a Router

    - by user19185
    I was watching this Video which talked about using port-forwarding to optimize your LAN for skype calls. According to the video, as explained in the first couple of minutes in the video, the reason you would need optimization is because if the person your call has a firewall setup, your connection has to go-through a third-party computer to connect to them. I believe I stated this correct (maybe not). None the less, my question is this: do both parties on the call need to enable port forwarding to optimize skype, or just one party (person)?

    Read the article

  • sendmail on Ubuntu won't send from www-data user

    - by bumperbox
    I if call mail() function in PHP from webserver (running as www-data) i get an error sending email. If i call the same script from the cmdline logged in as root, then it works If i switch user to www-data and run from the cmdline i get this error message WARNING: RunAsUser for MSP ignored, check group ids (egid=33, want=107) can not chdir(/var/spool/mqueue-client/): Permission denied Program mode requires special privileges, e.g., root or TrustedUser. FAILEDWARNING: RunAsUser for MSP ignored, check group ids (egid=33, want=107) can not chdir(/var/spool/mqueue-client/): Permission denied Program mode requires special privileges, e.g., root or TrustedUser. FAILEDTest Complete$ WARNING: RunAsUser for MSP ignored, check group ids (egid=33, want=107) I am guessing i need to do something in sendmail configuration I have googled for some solutions but have ended up more confused. Can someone let me know what configuration I need to change to fix so i can send from www-data user?

    Read the article

  • Code Trivia #4

    - by João Angelo
    Got the inspiration for this one in a recent stackoverflow question. What should the following code output and why? class Program { class Author { public string FirstName { get; set; } public string LastName { get; set; } public override string ToString() { return LastName + ", " + FirstName; } } static void Main() { Author[] authors = new[] { new Author { FirstName = "John", LastName = "Doe" }, new Author { FirstName = "Jane", LastName="Doe" } }; var line1 = String.Format("Authors: {0} and {1}", authors); Console.WriteLine(line1); string[] serial = new string[] { "AG27H", "6GHW9" }; var line2 = String.Format("Serial: {0}-{1}", serial); Console.WriteLine(line2); int[] version = new int[] { 1, 0 }; var line3 = String.Format("Version: {0}.{1}", version); Console.WriteLine(line3); } } Update: The code will print the first two lines // Authors: Doe, John and Doe, Jane // Serial: AG27H-6GHW9 and then throw an exception on the third call to String.Format because array covariance is not supported in value types. Given this the third call of String.Format will not resolve to String.Format(string, params object[]), like the previous two, but to String.Format(string, object) which fails to provide the second argument for the specified format and will then cause the exception.

    Read the article

  • Scene Graph for Deferred Rendering Engine

    - by Roy T.
    As a learning exercise I've written a deferred rendering engine. Now I'd like to add a scene graph to this engine but I'm a bit puzzled how to do this. On a normal (forward rendering engine) I would just add all items (All implementing IDrawable and IUpdateAble) to my scene graph, than travel the scene-graph breadth first and call Draw() everywhere. However in a deferred rendering engine I have to separate draw calls. First I have to draw the geometry, then the shadow casters and then the lights (all to different render targets), before I combine them all. So in this case I can't just travel over the scene graph and just call draw. The way I see it I either have to travel over the entire scene graph 3 times, checking what kind of object it is that has to be drawn, or I have to create 3 separate scene graphs that are somehow connected to each other. Both of these seem poor solutions, I'd like to handle scene objects more transparent. One other solution I've thought of was traveling trough the scene graph as normal and adding items to 3 separate lists, separating geometry, shadow casters and lights, and then iterating these lists to draw the correct stuff, is this better, and is it wise to repopulate 3 lists every frame?

    Read the article

  • Lazy coding is fun

    - by Anthony Trudeau
    Every once in awhile I get the opportunity to write an application that is important enough to do, but not important enough to do the right way -- meaning standards, best practices, good architecture, et al.  I call it lazy coding.  The industry calls it RAD (rapid application development). I started on the conversion tool at the end of last week.  It will convert our legacy data to a completely new system which I'm working on piece by piece.  It will be used in the future, but only the new parts because it'll only be necessary to convert the individual pieces of the data once.  It was the perfect opportunity to just whip something together, but it was still functional unlike a prototype or proof of concept.  Although I would never write an application like this for a customer (internal or external) this methodology (if you can call it that) works great for something like this. I wouldn't be surprised if I get flamed for equating RAD to lazy coding or lacking standards, best practice, or good architecture.  Unfortunately, it fits in the current usage.  Although, it's possible to create a good, maintainable application using the RAD methodology, it's just too ripe for abuse and requires too much discipline for someone let alone a team to do right. Sometimes it's just fun to throw caution to the wind and start slamming code.

    Read the article

  • Role of Sharepoint experience in career growth

    - by Syed Ibrahim
    I am from India. I was a Mainframe developer for first 2 years of my IT career and then shifted to Microsoft .Net and completed 3 years as of now. In these 3 years as a .Net developer i have worked only in core .Net skills like Asp .Net, Sql Server with C# .Net. I never worked in advance skills like Web Services or WCF or silverlight etc. In current world market scenario, I feel Sharepoint experience weighs more than the WCF, Web Services work experience for a .Net Developer.(Please correct if wrong). So i am planning to study Sharepoint through some training centre and complete a Sharepoint certification. The main reason for me to go for Sharepoint is that i feel it is a niche skill and it will help me to get a job in abroad location in future. Please let me know whether sharepoint can help me to get a job in foreign location. I would also like to know whether, Is it possible to master Sharepoint without any experience in skills like WCF, Web Services etc? Is it possible to get a sharepoint job just with knowledge and certification in it? Incase if sharepoint will not offer me career growth, then can you please suggest me the skills which will offer great career growth (like foreign jobs) for me as a .Net developer?

    Read the article

  • l'e-news Arrow ECS-Oracle

    - by mseika
    Si vous ne visualisez pas cet email, cliquez ici Agenda Accompagnement Arrow ECS Cut-off Q4FY12 Oracle SoftwareEn raison du closing Oracle de mai, les commandes Oracle doivent être enregistrées chez Arrow ECS avant : - Le 27 avril 2012 pour les commandes Hardware - Le 20 mai 2012 pour les commandes Software Pour plus d'information, contactez votre commercial dédié Oracle Les WebExperts Oracle by Arrow45 minutes pour monter en compétence grâce à nos formations gratuites en ligne.Prochaines sessions :- La tarification Oracle SW : 2 avril à 11h- Le programme OMM : 4 avril à 11h- ODA : l'appliance Oracle pour les PME-PMI : 16 avril à 11h- Weblogic, les différentes éditions : 2 mai 2012 à 11h Forum Big Data le 5 avrilDécouvrez comment Oracle va accélérer et faciliter vos projets de déploiement Big Data.Pour en savoir plus et vous inscrire Workshop technique Oracle VM3Venez découvrir les nouveautés d'Oracle VM3 et de Linux 6 lors d'un workshop technique, le 26 avril prochain à Colombes.Pour en savoir plus et vous inscrire Bootcamp ODA en régions Arrow vous propose des formations sur la solution Oracle Database Appliance.Les prochaines étapes : Aix, Bordeaux et Nantes.Préinscrivez-vous dès aujourd'hui ! "Bootcamp Implementation" Oracle : obtenez la préférence de vos clients en devenant spécialiste Oracle Nous vous proposons 2 sessions de préparation à ces examens au tarif spécial de 1090€ HT : - Oracle Database 11g Certified Implementation Specialist : du 23 au 27 avril 2012 - Oracle WebLogic Server 11g : Administration avancé, du 21 au 25 mai 2012 Inscrivez-vous vite, le nombre de places est limité.Pour en savoir plus, contactez l'équipe formation L'Exalabs Solution Center d'Arrow ECS Centre de formation unique en France, l'Exalabs Solution Center dispose de l'intégralité de l'infrastructure technique intégrée d'Oracle : Exadata, Exalogic, ODA...Mobile, il permet d'organiser des démonstrations pratiques, des séminaires de formation, des POC* in situ.*Proof Of ConceptFaîtes vos demandes auprès de notre équipe dédiée Ateliers de certification OracleLe passage des tests de certification est l'étape préalable vers la Spécialisation de votre société.Nous vous proposons de vous accompagner lors d'ateliers dédiés.Vous êtes intéressés ? Faites-le nous savoir Formez-vous sur les produits OracleVous souhaitez former vos commerciaux aux nouveaux produits Oracle : ODA, Exadata...Faîtes vos demandes auprès de notre équipe dédiée Lancez votre activité Oracle avec le Starter KitVous souhaitez démarrer votre business Oracle Software ou Oracle Hardware ?Arrow ECS vous propose un programme dédié pour vous aider à développer rapidement les ventes.Demandez votre Starter Kit L'équipe Oracle chez Arrow ECS - Tél : 01 49 97 59 63 - email : [email protected] Pour passer vos commandes, un n° de fax : 01 49 97 49 49

    Read the article

  • Godaddy hosting with dynamic ip?

    - by Razor Storm
    I bought a domain name on godaddy.com let's call it www.website.com, but my server has a dynamic ip, how do I resolve this issue? What I've tried: get a dns account at dyndns.com let's call it dns.dyndns.com, so I set up godaddy to forward the domain to dns.dyndns.com. problem: When the user goes to www.website.com, they see dns.dyndns.com in the url bar. Bad So then I set up the forwarding on godaddy to forward with domain masking, but then the problem is now that users can't even see url paths/get queries/ or hash marks anymore! `www.website.com/folder/search?id=4#ajax=4` becomes just www.website.com in the url bar. bad! What do I do?

    Read the article

  • Evil DRY

    - by StefanSteinegger
    DRY (Don't Repeat Yourself) is a basic software design and coding principle. But there is just no silver bullet. While DRY should increase maintainability by avoiding common design mistakes, it could lead to huge maintenance problems when misunderstood. The root of the problem is most probably that many developers believe that DRY means that any piece of code that is written more then once should be made reusable. But the principle is stated as "Every piece of knowledge must have a single, unambiguous, authoritative representation within a system." So the important thing here is "knowledge". Nobody ever said "every piece of code". I try to give some examples of misusing the DRY principle. Code Repetitions by Coincidence There is code that is repeated by pure coincidence. It is not the same code because it is based on the same piece of knowledge, it is just the same by coincidence. It's hard to give an example of such a case. Just think about some lines of code the developer thinks "I already wrote something similar". Then he takes the original code, puts it into a public method, even worse into a base class where none had been there before, puts some weird arguments and some if or switch statements into it to support all special cases and calls this "increasing maintainability based on the DRY principle". The resulting "reusable method" is usually something the developer not even can give a meaningful name, because its contents isn't anything specific, it is just a bunch of code. For the same reason, nobody will really understand this piece of code. Typically this method only makes sense to call after some other method had been called. All the symptoms of really bad design is evident. Fact is, writing this kind of "reusable methods" is worse then copy pasting! Believe me. What will happen when you change this weird piece of code? You can't say what'll happen, because you can't understand what the code is actually doing. So better don't touch it anymore. Maintainability just died. Of course this problem is with any badly designed code. But because the developer tried to make this method as reusable as possible, large parts of the system get dependent on it. Completely independent parts get tightly coupled by this common piece of code. Changing on the single common place will have effects anywhere in the system, a typical symptom of too tight coupling. Without trying to dogmatically (and wrongly) apply the DRY principle, you just had a system with a weak design. Now you get a system which just can't be maintained anymore. So what can you do against it? When making code reusable, always identify the generally reusable parts of it. Find the reason why the code is repeated, find the common "piece of knowledge". If you have to search too far, it's probably not really there. Explain it to a colleague, if you can't explain or the explanation is to complicated, it's probably not worth to reuse. If you identify the piece of knowledge, don't forget to carefully find the place where it should be implemented. Reusing code is never worth giving up a clean design. Methods always need to do something specific. If you can't give it a simple and explanatory name, you did probably something weird. If you can't find the common piece of knowledge, try to make the code simpler. For instance, if you have some complicated string or collection operations within this code, write some general-purpose operations into a helper class. If your code gets simple enough, its not so bad if it can't be reused. If you are not able to find anything simple and reasonable, copy paste it. Put a comment into the code to reference the other copies. You may find a solution later. Requirements Repetitions by Coincidence Let's assume that you need to implement complex tax calculations for many countries. It's possible that some countries have very similar tax rules. These rules are still completely independent from each other, since every country can change it of its own. (Assumed that this similarity is actually by coincidence and not by political membership. There might be basic rules applying to all European countries. etc.) Let's assume that there are similarities between an Asian country and an African country. Moving the common part to a central place will cause problems. What happens if one of the countries changes its rules? Or - more likely - what happens if users of one country complain about an error in the calculation? If there is shared code, it is very risky to change it, even for a bugfix. It is hard to find requirements to be repeated by coincidence. Then there is not much you can do against the repetition of the code. What you really should consider is to make coding of the rules as simple as possible. So this independent knowledge "Tax Rules in Timbuktu" or wherever should be as pure as possible, without much overhead and stuff that does not belong to it. So you can write every independent requirement short and clean. DRYing try-catch and using Blocks This is a technical issue. Blocks like try-catch or using (e.g. in C#) are very hard to DRY. Imagine a complex exception handling, including several catch blocks. When the contents of the try block as well as the contents of the individual catch block are trivial, but the whole structure is repeated on many places in the code, there is almost no reasonable way to DRY it. try { // trivial code here using (Thingy thing = new thingy) { //trivial, but always different line of code } } catch(FooException foo) { // trivial foo handling } catch (BarException bar) { // trivial bar handling } catch { // trivial common handling } finally { // trivial finally block } The key here is that every block is trivial, so there is nothing to just move into a separate method. The only part that differs from case to case is the line of code in the body of the using block (or any other block). The situation is especially interesting if the many occurrences of this structure are completely independent: they appear in classes with no common base class, they don't aggregate each other and so on. Let's assume that this is a common pattern in service methods within the whole system. Examples of Evil DRYing in this situation: Put a if or switch statement into the method to choose the line of code to execute. There are several reasons why this is not a good idea: The close coupling of the formerly independent implementation is the strongest. Also the readability of the code and the use of a parameter to control the logic. Put everything into a method which takes a delegate as argument to call. The caller just passes his "specific line of code" to this method. The code will be very unreadable. The same maintainability problems apply as for any "Code Repetition by Coincidence" situations. Enforce a base class to all the classes where this pattern appears and use the template method pattern. It's the same readability and maintainability problem as above, but additionally complex and tightly coupled because of the base class. I would call this "Inheritance by Coincidence" which will not lead to great software design. What can you do against it: Ideally, the individual line of code is a call to a class or interface, which could be made individual by inheritance. If this would be the case, it wouldn't be a problem at all. I assume that it is no such a trivial case. Consider to refactor the error concept to make error handling easier. The last but not worst option is to keep the replications. Some pattern of code must be maintained in consistency, there is nothing we can do against it. And no reason to make it unreadable. Conclusion The DRY-principle is an important and basic principle every software developer should master. The key is to identify the "pieces of knowledge". There is code which can't be reused easily because of technical reasons. This requires quite a bit flexibility and creativity to make code simple and maintainable. It's not the problem of the principle, it is the problem of blindly applying a principle without understanding the problem it should solve. The result is mostly much worse then ignoring the principle.

    Read the article

< Previous Page | 184 185 186 187 188 189 190 191 192 193 194 195  | Next Page >