Search Results

Search found 9894 results on 396 pages for 'primary interop assembly'.

Page 19/396 | < Previous Page | 15 16 17 18 19 20 21 22 23 24 25 26  | Next Page >

  • What is the easiest way to get the primary groupName from AD in C#?

    - by madhatter84gn
    I am currently using PrincipalContext and UserPrincipal to return the users primary groupid. How can I take this id and find the actual group name? Also I have code that works correctly to assign the user's primary group, but once I assign them to the group I can not delete them from Domain Users which is the default primary group prior to my change. I have called Save() before trying to remove the domain users group. My requirements state I must add the user to AD then assign their primary group and then remove them as a member of Domain Users.

    Read the article

  • Why can't set cast an object from Excel interop?

    - by AngryHacker
    Trying to get a reference to the worksheets (using Excel interop): Excel.Application xl = new Excel.ApplicationClass(); Excel.Workbooks xlWorkBooks = xl.Workbooks; Excel.Workbook xlWorkBook = xlWorkBooks.Open(fileName, 0, false, 5, "", "", true, Excel.XlPlatform.xlWindows, "\t", false, false, 0, true, 1, 0); Excel.Worksheets xlWorkSheets = (Excel.Worksheets) xlWorkBook.Worksheets; // crashes The error is that it cannot cast it: Unable to cast COM object of type 'System.__ComObject' to interface type 'Microsoft.Office.Interop.Excel.Worksheets'. This operation failed because the QueryInterface call on the COM component for the interface with IID '{000208B1-0000-0000-C000-000000000046}' failed due to the following error: No such interface supported (Exception from HRESULT: 0x80004002 (E_NOINTERFACE)). Is my cast incorrect?

    Read the article

  • How to migrate primary key generation from "increment" to "hi-lo"?

    - by Bevan
    I'm working with a moderate sized SQL Server 2008 database (around 120 tables, backups are around 4GB compressed) where all the table primary keys are declared as simple int columns. At present, primary key values are generated by NHibernate with the increment identity generator, which has worked well thus far, but precludes moving to a multiprocessing environment. Load on the system is growing, so I'm evaluating the work required to allow the use of multiple servers accessing a common database backend. Transitioning to the hi-lo generator seems to be the best way forward, but I can't find a lot of detail about how such a migration would work. Will NHibernate automatically create rows in the hi-lo table for me, or do I need to script these manually? If NHibernate does insert rows automatically, does it properly take account of existing key values? If NHibernate does take care of thing automatically, that's great. If not, are there any tools to help? Update NHibernate's increment identifier generator works entirely in-memory. It's seeded by selecting the maximum value of used identifiers from the table, but from that point on allocates new values by a simple increment, without reference back to the underlying database table. If any other process adds rows to the table, you end up with primary key collisions. You can run multiple threads within the one process just fine, but you can't run multiple processes. For comparison, the NHibernate identity generator works by configuring the database tables with identity columns, putting control over primary key generation in the hands of the database. This works well, but compromises the unit of work pattern. The hi-lo algorithm sits inbetween these - generation of primary keys is coordinated through the database, allowing for multiprocessing, but actual allocation can occur entirely in memory, avoiding problems with the unit of work pattern.

    Read the article

  • Optimize MySQL query (ngrams, COUNT(), GROUP BY, ORDER BY)

    - by Gerardo
    I have a database with thousands of companies and their locations. I have implemented n-grams to optimize search. I am making one query to retrieve all the companies that match with the search query and another one to get a list with their locations and the number of companies in each location. The query I am trying to optimize is the latter. Maybe the problem is this: Every company ('anunciante') has a field ('estado') to make logical deletes. So, if 'estado' equals 1, the company should be retrieved. When I run the EXPLAIN command, it shows that it goes through almost 40k rows, when the actual result (the reality matching companies) are 80. How can I optimize this? This is my query (XXX represent the n-grams for the search query): SELECT provincias.provincia AS provincia, provincias.id, COUNT(*) AS cantidad FROM anunciantes JOIN anunciante_invertido AS a_i0 ON anunciantes.id = a_i0.id_anunciante JOIN indice_invertido AS indice0 ON a_i0.id_invertido = indice0.id LEFT OUTER JOIN domicilios ON anunciantes.id = domicilios.id_anunciante LEFT OUTER JOIN localidades ON domicilios.id_localidad = localidades.id LEFT OUTER JOIN provincias ON provincias.id = localidades.id_provincia WHERE anunciantes.estado = 1 AND indice0.id IN (SELECT invertido_ngrama.id_palabra FROM invertido_ngrama JOIN ngrama ON ngrama.id = invertido_ngrama.id_ngrama WHERE ngrama.ngrama = 'XXX') AND indice0.id IN (SELECT invertido_ngrama.id_palabra FROM invertido_ngrama JOIN ngrama ON ngrama.id = invertido_ngrama.id_ngrama WHERE ngrama.ngrama = 'XXX') AND indice0.id IN (SELECT invertido_ngrama.id_palabra FROM invertido_ngrama JOIN ngrama ON ngrama.id = invertido_ngrama.id_ngrama WHERE ngrama.ngrama = 'XXX') AND indice0.id IN (SELECT invertido_ngrama.id_palabra FROM invertido_ngrama JOIN ngrama ON ngrama.id = invertido_ngrama.id_ngrama WHERE ngrama.ngrama = 'XXX') AND indice0.id IN (SELECT invertido_ngrama.id_palabra FROM invertido_ngrama JOIN ngrama ON ngrama.id = invertido_ngrama.id_ngrama WHERE ngrama.ngrama = 'XXX') GROUP BY provincias.id ORDER BY cantidad DESC And this is the query explained (hope it can be read in this format): id select_type table type possible_keys key key_len ref rows Extra 1 PRIMARY anunciantes ref PRIMARY,estado estado 1 const 36669 Using index; Using temporary; Using filesort 1 PRIMARY domicilios ref id_anunciante id_anunciante 4 db84771_viaempresas.anunciantes.id 1 1 PRIMARY localidades eq_ref PRIMARY PRIMARY 4 db84771_viaempresas.domicilios.id_localidad 1 1 PRIMARY provincias eq_ref PRIMARY PRIMARY 4 db84771_viaempresas.localidades.id_provincia 1 1 PRIMARY a_i0 ref PRIMARY,id_anunciante,id_invertido PRIMARY 4 db84771_viaempresas.anunciantes.id 1 Using where; Using index 1 PRIMARY indice0 eq_ref PRIMARY PRIMARY 4 db84771_viaempresas.a_i0.id_invertido 1 Using index 6 DEPENDENT SUBQUERY ngrama const PRIMARY,ngrama ngrama 5 const 1 Using index 6 DEPENDENT SUBQUERY invertido_ngrama eq_ref PRIMARY,id_palabra,id_ngrama PRIMARY 8 func,const 1 Using index 5 DEPENDENT SUBQUERY ngrama const PRIMARY,ngrama ngrama 5 const 1 Using index 5 DEPENDENT SUBQUERY invertido_ngrama eq_ref PRIMARY,id_palabra,id_ngrama PRIMARY 8 func,const 1 Using index 4 DEPENDENT SUBQUERY ngrama const PRIMARY,ngrama ngrama 5 const 1 Using index 4 DEPENDENT SUBQUERY invertido_ngrama eq_ref PRIMARY,id_palabra,id_ngrama PRIMARY 8 func,const 1 Using index 3 DEPENDENT SUBQUERY ngrama const PRIMARY,ngrama ngrama 5 const 1 Using index 3 DEPENDENT SUBQUERY invertido_ngrama eq_ref PRIMARY,id_palabra,id_ngrama PRIMARY 8 func,const 1 Using index 2 DEPENDENT SUBQUERY ngrama const PRIMARY,ngrama ngrama 5 const 1 Using index 2 DEPENDENT SUBQUERY invertido_ngrama eq_ref PRIMARY,id_palabra,id_ngrama PRIMARY 8 func,const 1 Using index

    Read the article

  • Is it a good idea to use a computed column as part of a primary key ?

    - by Brann
    I've got a table defined as : OrderID bigint NOT NULL, IDA varchar(50) NULL, IDB bigint NULL, [ ... 50 other non relevant columns ...] The natural primary key for this table would be (OrderID,IDA,IDB), but this it not possible because IDA and IDB can be null (they can both be null, but they are never both defined at the same time). Right now I've got a unique constraint on those 3 columns. Now, the thing is I need a primary key to enable transactional replication, and I'm faced with two choices : Create an identity column and use it as a primary key Create a non-null computed column C containing either IDA or IDB or '' if both columns were null, and use (OrderID,C) as my primary key. The second alternative seams cleaner as my PK would be meaningful, and is feasible (see msdn link), but since I've never seen this done anywhere, I was wondering if they were some cons to this approach.

    Read the article

  • MSSQL: Primary Key Schema Largely Guid but Sometimes Integer Types...

    - by Code Sherpa
    OK, this may be a silly question but... I have inherited a project and am tasked with going over the primary key relationships. The project largely uses Guids. I say "largely" because there are examples where tables use integral types to reflect enumerations. For example, dbo.MessageFolder has MessageFolderId of type int to reflect public emum MessageFolderTypes { inbox = 1, sent = 2, trash = 3, etc... } This happens a lot. There are tables with primary keys of type int which is unavoidable because of their reliance on enumerations and tables with primary keys of type Guid which reflect the primary key choice on the part of the previous programmer. Should I care that the PK schema is spotty like this? It doesn't feel right but does it really matter? If this could create a problem, how do I get around it (I really can't move all PKs to type int without serious legwork and I have never heard of enumerations that have guid values)? Thanks.

    Read the article

  • SQL Server: Primary Key Schema Largely Guid but Sometimes Integer Types...

    - by Code Sherpa
    OK, this may be a silly question but... I have inherited a project and am tasked with going over the primary key relationships. The project largely uses Guids. I say "largely" because there are examples where tables use integral types to reflect enumerations. For example, dbo.MessageFolder has MessageFolderId of type int to reflect public emum MessageFolderTypes { inbox = 1, sent = 2, trash = 3, etc... } This happens a lot. There are tables with primary keys of type int which is unavoidable because of their reliance on enumerations and tables with primary keys of type Guid which reflect the primary key choice on the part of the previous programmer. Should I care that the PK schema is spotty like this? It doesn't feel right but does it really matter? If this could create a problem, how do I get around it (I really can't move all PKs to type int without serious legwork and I have never heard of enumerations that have guid values)? Thanks.

    Read the article

  • How does AssemblyName.ReferenceMatchesDefinition work?

    - by Fabian Schmied
    Given the following code: var n1 = new AssemblyName ("TestDll, Version=1.0.0.0, Culture=Neutral, PublicKeyToken=b77a5c561934e089"); var n2 = new AssemblyName ("TestDll, Version=2.0.0.2001, Culture=en-US, PublicKeyToken=ab7a5c561934e089"); Console.WriteLine (AssemblyName.ReferenceMatchesDefinition (n1, n2)); Console.WriteLine (AssemblyName.ReferenceMatchesDefinition (n2, n1)); Why do both of these checks print "True"? I would have thought that AssemblyName.ReferenceMatchesDefinition should consider differences in the version, culture, and public key token attributes of an assembly name, shouldn't they? If not, what does ReferenceMatchesDefinition do that a comparison of the simple names doesn't?

    Read the article

  • ILMerge - Unresolved assembly reference not allowed: System.Core

    - by Steve Michelotti
    ILMerge is a utility which allows you the merge multiple .NET assemblies into a single binary assembly more for convenient distribution. Recently we ran into problems when attempting to use ILMerge on a .NET 4 project. We received the error message: An exception occurred during merging: Unresolved assembly reference not allowed: System.Core.     at System.Compiler.Ir2md.GetAssemblyRefIndex(AssemblyNode assembly)     at System.Compiler.Ir2md.GetTypeRefIndex(TypeNode type)     at System.Compiler.Ir2md.VisitReferencedType(TypeNode type)     at System.Compiler.Ir2md.GetMemberRefIndex(Member m)     at System.Compiler.Ir2md.PopulateCustomAttributeTable()     at System.Compiler.Ir2md.SetupMetadataWriter(String debugSymbolsLocation)     at System.Compiler.Ir2md.WritePE(Module module, String debugSymbolsLocation, BinaryWriter writer)     at System.Compiler.Writer.WritePE(String location, Boolean writeDebugSymbols, Module module, Boolean delaySign, String keyFileName, String keyName)     at System.Compiler.Writer.WritePE(CompilerParameters compilerParameters, Module module)     at ILMerging.ILMerge.Merge()     at ILMerging.ILMerge.Main(String[] args) It turns out that this issue is caused by ILMerge.exe not being able to find the .NET 4 framework by default. The answer was ultimately found here. You either have to use the /lib option to point to your .NET 4 framework directory (e.g., “C:\Windows\Microsoft.NET\Framework\v4.0.30319” or “C:\Windows\Microsoft.NET\Framework64\v4.0.30319”) or just use an ILMerge.exe.config file that looks like this: 1: <configuration> 2: <startup useLegacyV2RuntimeActivationPolicy="true"> 3: <requiredRuntime safemode="true" imageVersion="v4.0.30319" version="v4.0.30319"/> 4: </startup> 5: </configuration> This was able to successfully resolve my issue.

    Read the article

  • Incrementing Assembly Version in TFS Builds and its affect over Other Build Definitions

    - by ssmantha
    A very common scenario while performing TFS builds is to increment version number of the assemblies. There are quite a few approaches of which I would like to share two links: Ewald Hofman’s Approach: http://www.ewaldhofman.nl/post/2010/05/13/Customize-Team-Build-2010-e28093-Part-5-Increase-AssemblyVersion.aspx#id_02e7b082-ce95-49a9-92e9-7dc88887b377 Richard Bank’s Approach : http://www.richard-banks.org/2010/07/how-to-versioning-builds-with-tfs-2010.html   Both these approaches work well, however there are scenarios where Editing and Checking–in the Assembly version information can create problems with Build Definitions meant for Continuous Integration, or gated Check-ins. You can suppress the Continuous Integration Builds while checking in the Assembly info file by just putting a comment “***NO_CI***” as specified by Ewald in his blog. However, if you have Gated Checkin in place, this can turn out to be difficult to suppress, I myself tried to suppress the Build Trigger during the check in process but things doesn’t turn out well. That’s where Richard’s solution comes as handy. Both the solutions have their own pros and cons, which I believe can only be experienced over a period of time. In case of Richard’s solution I believe that we don’t have any history of the Assembly Version Info file and when you take latest of the solution the information will be lost. If you notice closely, that suppressing the Continuous Integration (the NO_CI approach in check in comments) is a workaround provided by Microsoft, however I didn’t find anything to suppress the gated Checkin so far. Suggestions or Findings are most welcome.

    Read the article

  • Dynamic LINQ in an Assembly Near By

    - by Ricardo Peres
    You may recall my post on Dynamic LINQ. I said then that you had to download Microsoft's samples and compile the DynamicQuery project (or just grab my copy), but there's another way. It turns out Microsoft included the Dynamic LINQ classes in the System.Web.Extensions assembly, not the one from ASP.NET 2.0, but the one that was included with ASP.NET 3.5! The only problem is that all types are private: Here's how to use it: Assembly asm = typeof(UpdatePanel).Assembly; Type dynamicExpressionType = asm.GetType("System.Web.Query.Dynamic.DynamicExpression"); MethodInfo parseLambdaMethod = dynamicExpressionType.GetMethods(BindingFlags.Public | BindingFlags.Static).Where(m = (m.Name == "ParseLambda") && (m.GetParameters().Length == 2)).Single().MakeGenericMethod(typeof(DateTime), typeof(Boolean)); Func filterExpression = (parseLambdaMethod.Invoke(null, new Object [] { "Year == 2010", new Object [ 0 ] }) as Expression).Compile(); List list = new List { new DateTime(2010, 1, 1), new DateTime(1999, 1, 12), new DateTime(1900, 10, 10), new DateTime(1900, 2, 20), new DateTime(2012, 5, 5), new DateTime(2012, 1, 20) }; IEnumerable filteredDates = list.Where(filterExpression); SyntaxHighlighter.config.clipboardSwf = 'http://alexgorbatchev.com/pub/sh/2.0.320/scripts/clipboard.swf'; SyntaxHighlighter.brushes.CSharp.aliases = ['c#', 'c-sharp', 'csharp']; SyntaxHighlighter.all();

    Read the article

  • Oracle 64-bit assembly throws BadImageFormatException when running unit tests

    - by pjohnson
    We recently upgraded to the 64-bit Oracle client. Since then, Visual Studio 2010 unit tests that hit the database (I know, unit tests shouldn't hit the database--they're not perfect) all fail with this error message:Test method MyProject.Test.SomeTest threw exception: System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation. ---> System.BadImageFormatException: Could not load file or assembly 'Oracle.DataAccess, Version=4.112.3.0, Culture=neutral, PublicKeyToken=89b483f429c47342' or one of its dependencies. An attempt was made to load a program with an incorrect format.I resolved this by changing the test settings to run tests in 64-bit. From the Test menu, go to Edit Test Settings, and pick your settings file. Go to Hosts, and change the "Run tests in 32 bit or 64 bit process" dropdown to "Run tests in 64 bit process on 64 bit machine". Now your tests should run.This fix makes me a little nervous. Visual Studio 2010 and earlier seem to change that file for no apparent reason, add more settings files, etc. If you're not paying attention, you could have TestSettings1.testsettings through TestSettings99.testsettings sitting there and never notice the difference. So it's worth making a note of how to change it in case you have to redo it, and being vigilant about files VS tries to add.I'm not entirely clear on why this was even a problem. Isn't that the point of an MSIL assembly, that it's not specific to the hardware it runs on? An IL disassembler can open the Oracle.DataAccess.dll in question, and in its Runtime property, I see the value "v4.0.30319 / x64". So I guess the assembly was specifically build to target 64-bit platforms only, possibly due to a 64-bit-specific difference in the external Oracle client upon which it depends. Most other assemblies, especially in the .NET Framework, list "msil", and a couple list "x86". So I guess this is another entry in the long list of ways Oracle refuses to play nice with Windows and .NET.If this doesn't solve your problem, you can read others' research into this error, and where to change the same test setting in Visual Studio 2012.

    Read the article

  • Configuring network to set wlan0 as primary

    - by Sheed
    I recently had to rebuild my pc and decided to go for ubuntu 14.04. I think the mistake I made was I started from a 12.04 install disk instead of the 12.10 disk I'd used previously and when given the option set my primary connection as ethernet (because the wireless option didn't work). After upgrading to 14.04 etc, I managed to get the wireless working, or more using steps like ifconfig -a and the likes I managed to prove that the wireless card etc. is all installed and working. However every time I boot without a hard wired connection plugged in I get the message "waiting for network configuration". I can then once it's booted without a network get my wirless working using sudo ifconfig wlan0 up iwlist wlan0 scan This seems to kick the wireless module into life and it appears in the GUI and I can then select a network, however all the options like edit network and disconnect etc are all greyed out. What I would like of course is if the WLAN0 was just set as my primary default network so I've been looking for a solution to this and it would seem that I need to adjust the old /etc/network/interfaces file but when I try to do so using the sudo vi /etc/network/interfaces command I, well I simply have no idea what I'm doing. Other than that typing :q! gets me out of there before I do to much damage! As far as I can tell (by navigating to the file in the GUI) the output of my /etc/network/interfaces is as follows: (obviously not including the " in each line that's just to break the heading rule of the #) "# This file describes the network interfaces available on your system "# and how to activate them. For more information, see interfaces(5). "# The loopback network interface auto lo iface lo inet loopback "# The primary network interface auto eth0 iface eth0 inet dhcp If this is the case then this clearly doesn't contain what it should do but I don't how to fix it. Nor do I even know if I'm on the right track. Any help would be appreciated thanks :)

    Read the article

  • Need to call COM component using reflections in C#.NET

    - by Usman
    Hello, I need to determin the COM component(unmanaged code) type and invoke the exposed interface's methods using reflection in C#.NET at runtime. 1 -- First What member of "Type" tells that type is COM component and we can take CLSID at runtime? Is Type.COMObject? 2 -- I need to call methods of exposed interfaces as they called in unmanaged code using CoCreateInstance by passing CLSID and REFID ... I am using InvokeMember but it returns null or 0 as out parameter. How to pass out parameter in this case.? Is there any need to pass out parameter? As all my COM unamanged code suppose to take las parameter as an OUT parameter and after executing it puts the result into that out param. But I've converted all my unmanged COM code to .NET managed assemblies using tlbimp.exe. Regards Usman

    Read the article

  • Interop effects by resolving and instantiating types with ArcObjects

    - by Marko Apfel
    Problem this code does not work Type t = typeof(ESRI.ArcGIS.Framework.AppRefClass); System.Object obj = Activator.CreateInstance(t); but yet this code Type t = Type.GetTypeFromCLSID(typeof(ESRI.ArcGIS.Framework.AppRefClass).GUID); System.Object obj = Activator.CreateInstance(t); Reason In the first variant the runtime tries to cast to AppRefClass . This is not possible. And in the second one, the runtime does not knows anything about AppRefClass. So it leave it as IUnknown.   (originally communicated by my co-worker Ralf)

    Read the article

  • Windows Azure Interop

    - by kaleidoscope
    How Windows Azure Platform is an open cloud platform. What makes it interoperable? The Windows Azure platform supports popular standards and protocols including SOAP, REST, and XML. Developers can use their preferred programming frameworks including .NET, and PHP, now. Tools such as Eclipse have been created for PHP developers for building Windows Azure applications. Now external endpoints (inbound traffic) have been enabled to worker a role, which enables applications that receive internet traffic that aren’t running under IIS. Windows Azure interoperable with Java At PDC 09, solution accelerator for Tomcat is delivered. Tomcat is an open source software implementation of the Java Servlet and JavaServer Pages technologies. The Windows Azure solution accelerator leverages a PDC09 feature that enable arbitrary processes to bind to inbound service endpoints. Windows Azure interoperable with PHP The Windows Azure tools for Eclipse extension builds upon the PHP Development Toolkit (PDT) and integrates Web Tools Platform (WTP) to provide a complete toolkit for Windows Azure web application development. For more details please refer to the link: http://www.microsoft.com/windowsazure/faq/   Rituraj

    Read the article

  • I can't get SetSystemTime to work in Windows Vista using C# with Interop (P/Invoke).

    - by Andrew
    Hi, I'm having a hard time getting SetSystemTime working in my C# code. SetSystemtime is a kernel32.dll function. I'm using P/invoke (interop) to call it. SetSystemtime returns false and the error is "Invalid Parameter". I've posted the code below. I stress that GetSystemTime works just fine. I've tested this on Vista and Windows 7. Based on some newsgroup postings I've seen I have turned off UAC. No difference. I have done some searching for this problem. I found this link: http://groups.google.com.tw/group/microsoft.public.dotnet.framework.interop/browse_thread/thread/805fa8603b00c267 where the problem is reported but no resolution seems to be found. Notice that UAC is also mentioned but I'm not sure this is the problem. Also notice that this gentleman gets no actual Win32Error. Can someone try my code on XP? Can someone tell me what I'm doing wrong and how to fix it. If the answer is to somehow change permission settings programatically, I'd need an example. I would have thought turning off UAC should cover that though. I'm not required to use this particular way (SetSystemTime). I'm just trying to introduce some "clock drift" to stress test something. If there's another way to do it, please tell me. Frankly, I'm surprised I need to use Interop to change the system time. I would have thought there is a .NET method. Thank you very much for any help or ideas. Andrew Code: using System; using System.Collections.Generic; using System.Linq; using System.Text; using System.Runtime.InteropServices; namespace SystemTimeInteropTest { class Program { #region ClockDriftSetup [StructLayout(LayoutKind.Sequential)] public struct SystemTime { [MarshalAs(UnmanagedType.U2)] public short Year; [MarshalAs(UnmanagedType.U2)] public short Month; [MarshalAs(UnmanagedType.U2)] public short DayOfWeek; [MarshalAs(UnmanagedType.U2)] public short Day; [MarshalAs(UnmanagedType.U2)] public short Hour; [MarshalAs(UnmanagedType.U2)] public short Minute; [MarshalAs(UnmanagedType.U2)] public short Second; [MarshalAs(UnmanagedType.U2)] public short Milliseconds; } [DllImport("kernel32.dll")] public static extern void GetLocalTime( out SystemTime systemTime); [DllImport("kernel32.dll")] public static extern void GetSystemTime( out SystemTime systemTime); [DllImport("kernel32.dll", SetLastError = true)] public static extern bool SetSystemTime( ref SystemTime systemTime); //[DllImport("kernel32.dll", SetLastError = true)] //public static extern bool SetLocalTime( //ref SystemTime systemTime); [System.Runtime.InteropServices.DllImportAttribute("kernel32.dll", EntryPoint = "SetLocalTime")] [return: System.Runtime.InteropServices.MarshalAsAttribute(System.Runtime.InteropServices.UnmanagedType.Bool)] public static extern bool SetLocalTime([InAttribute()] ref SystemTime lpSystemTime); #endregion ClockDriftSetup static void Main(string[] args) { try { SystemTime sysTime; GetSystemTime(out sysTime); sysTime.Milliseconds += (short)80; sysTime.Second += (short)3000; bool bResult = SetSystemTime(ref sysTime); if (bResult == false) throw new System.ComponentModel.Win32Exception(); } catch (Exception ex) { Console.WriteLine("Drift Error: " + ex.Message); } } } }

    Read the article

  • How Does a COM Program Locate a .NET DLL Registered for COM Interop?

    - by Eric J.
    One customer wants to consume our .NET DLLs from VB6. They are designed to support reverse interop and all works fine... except: There are two separate VB6 programs in two different directories. It seems it's necessary to do one of: Copy the .NET DLL into both directories, or Install the .NET DLL in the GAC This is the customer's observation and also supported by the RegAsm documentation: After registering an assembly using Regasm.exe, you can install it in the global assembly cache so that it can be activated from any COM client. If the assembly is only going to be activated by a single application, you can place it in that application's directory. I'm confused on this point. First point of confusion: As far as I understand, the COM runtime locates the DLL using the Prog ID / Class ID. When I look in the registry at the Class ID entry, I see the full path to the .NET DLL in the CodeBase key. Why is it that a COM program using the Prog ID / Class ID doesn't locate the .NET DLL using the CodeBase? Second point of confusion: The GAC is specific to .NET. How is it involved in resolving COM references?

    Read the article

  • Azure git deployment - missing references in 2nd assembly

    - by Dan
    I'm trying to setup Bitbucket deployment to an Azure website. I successfully have Bitbucket and Azure linked, but when I push to Bitbucket, I get the following error on the Azure site: If I click on 'View Log', it shows the following compile errors: D:\Windows\Microsoft.NET\Framework\v4.0.30319\Microsoft.Common.targets(1578,5): warning MSB3245: Could not resolve this reference. Could not locate the assembly "System.Web.Mvc, Version=4.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35, processorArchitecture=MSIL". Check to make sure the assembly exists on disk. If this reference is required by your code, you may get compilation errors. [C:\DWASFiles\Sites\<projname>\VirtualDirectory0\site\repository\<projname>.Common\<projname>.Common.csproj] D:\Windows\Microsoft.NET\Framework\v4.0.30319\Microsoft.Common.targets(1578,5): warning MSB3245: Could not resolve this reference. Could not locate the assembly "WebMatrix.WebData, Version=2.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35, processorArchitecture=MSIL". Check to make sure the assembly exists on disk. If this reference is required by your code, you may get compilation errors. [C:\DWASFiles\Sites\<projname>\VirtualDirectory0\site\repository\<projname>.Common\<projname>.Common.csproj] CustomMembershipProvider.cs(5,7): error CS0246: The type or namespace name 'WebMatrix' could not be found (are you missing a using directive or an assembly reference?) [C:\DWASFiles\Sites\<projname>\VirtualDirectory0\site\repository\<projname>.Common\<projname>.Common.csproj] CustomMembershipProvider.cs(9,38): error CS0246: The type or namespace name 'ExtendedMembershipProvider' could not be found (are you missing a using directive or an assembly reference?) [C:\DWASFiles\Sites\<projname>\VirtualDirectory0\site\repository\<projname>.Common\<projname>.Common.csproj] Models\AccountModels.cs(3,18): error CS0234: The type or namespace name 'Mvc' does not exist in the namespace 'System.Web' (are you missing an assembly reference?) [C:\DWASFiles\Sites\<projname>\VirtualDirectory0\site\repository\<projname>.Common\<projname>.Common.csproj] CustomMembershipProvider.cs(198,37): error CS0246: The type or namespace name 'OAuthAccountData' could not be found (are you missing a using directive or an assembly reference?) [C:\DWASFiles\Sites\<projname>\VirtualDirectory0\site\repository\<projname>.Common\<projname>.Common.csproj] Models\AccountModels.cs(40,10): error CS0246: The type or namespace name 'Compare' could not be found (are you missing a using directive or an assembly reference?) [C:\DWASFiles\Sites\<projname>\VirtualDirectory0\site\repository\<projname>.Common\<projname>.Common.csproj] Models\AccountModels.cs(40,10): error CS0246: The type or namespace name 'CompareAttribute' could not be found (are you missing a using directive or an assembly reference?) [C:\DWASFiles\Sites\<projname>\VirtualDirectory0\site\repository\<projname>.Common\<projname>.Common.csproj] Models\AccountModels.cs(73,10): error CS0246: The type or namespace name 'Compare' could not be found (are you missing a using directive or an assembly reference?) [C:\DWASFiles\Sites\<projname>\VirtualDirectory0\site\repository\<projname>.Common\<projname>.Common.csproj] Models\AccountModels.cs(73,10): error CS0246: The type or namespace name 'CompareAttribute' could not be found (are you missing a using directive or an assembly reference?) [C:\DWASFiles\Sites\<projname>\VirtualDirectory0\site\repository\<projname>.Common\<projname>.Common.csproj] Note that these compile errors are against another assembly in my project (the assembly where I put the business logic). When Googling, the only mention I found was about having to set the "local copy" flag to true for those references. I've tried this, but still got the same errors. This all compiles fine locally. Any ideas?

    Read the article

  • InvalidCastException when creating an instance using assembly.CreateInstance

    - by Yossi Dahan
    I'm looking for an explanation for the following - I have an assembly I'm loading using Assembly assembly = Assembly.LoadFrom(filename); I then loop on all the types in the assembly, and wish to try and find out if a type implements a particular interface and if so I want an instance of that type, I've tried several things which did not work, but when I fell back to the most basic (and probably inefficient) way, I realised there's something more fundamental I don't understand - foreach (Type t in assembly.GetTypes()) { foreach (Type i in t.GetInterfaces()) { if (i.FullName == pluginInterfaceType.FullName) { object o = assembly.CreateInstance(t.ToString()); IInterface plugin = (IInterface)o; That last line causes an InvalidCastException, despite the fact that the type created definitely implements that interface. Further more - if I use Activator.CreateInstance instead of Assembly.CreateInstance (which I don't want to do), casting to the interface works just fine.

    Read the article

  • Relationship between .NET ClassLoader and Assembly

    - by smwikipedia
    I am wondering about the relationship between .NET ClassLoader and Assembly I use the "!dumpdomain xxxx" command and got the following output: Domain 1: 00522108 LowFrequencyHeap: 0052212c HighFrequencyHeap: 00522178 StubHeap: 005221c4 Stage: OPEN SecurityDescriptor: 00523430 Name: BoxUnbox.exe **Assembly**: 0056eb88 [C:\Windows\assembly\GAC_32\mscorlib\2.0.0.0__b77a5c561934e089\mscorlib.dll] **ClassLoader**: 0056ec08 SecurityDescriptor: 0056c078 Module Name 56d71000 C:\Windows\assembly\GAC_32\mscorlib\2.0.0.0__b77a5c561934e089\mscorlib.dll **Assembly**: 005794f0 [] **ClassLoader**: 00579570 SecurityDescriptor: 0057a018 Module Name 00152c5c I noticed that the "ClassLoader" and "Assembly" appear in pair. It seems each Assembly is accompanied with its own "ClassLoader". Why like this? Is this a litte noisy? Why not just assign one "ClassLoader" to a AppDomain and use it to load all the used Assembly into the AppDomain? Isnt't this design more elegant? Many thanks.

    Read the article

  • How to remove the error "Cant find PInvoke DLL SQLite.interop.dll"

    - by Shailesh Jaiswal
    I am developing windows mobile application. I am using the SQLlite database. I am using the following code to connect to this database as follows SQLiteConnection cn = new SQLiteConnection(); SQLiteDataReader SQLiteDR; cn.ConnectionString = @"Data Source=F:\CompNetDB.db3"; cn.Open(); SQLiteCommand cmd = new SQLiteCommand(); cmd.CommandText = "select * from CustomerInfo"; cmd.CommandType = CommandType.Text; cmd.Connection = cn; SQLiteDR = cmd.ExecuteReader(); In the above case I am getting the error "Cant find PInvike DLL SQLite.interop.dll". I have added the DLL System.Data.SQLLite from the \SQLite.NET\bin\compactframework this folder. This is the folder which is installed by default when I installed the SQLite. In the same folder there is one DLL file named SQLlite.Interop.66.DLL. When I try to add reference to this dll it is giving error that dll can not be added. Are the two dlls SQLlite.Interop.dll & System.Interop.066.dll same ? In the above code how to solve the error "Cant find PInvoke.SQLite.Interop.dll" Please can you tell whether there is mistake in my code or I am missing something in my application?

    Read the article

  • To what degree should I use Marshal.ReleaseComObject with Excel Interop objects?

    - by DanM
    I've seen several examples where Marshal.ReleaseComObject() is used with Excel Interop objects (i.e., objects from namespace Microsoft.Office.Interop.Excel), but I've seen it used to various degrees. I'm wondering if I can get away with something like this: var application = new ApplicationClass(); try { // do work with application, workbooks, worksheets, cells, etc. } finally { Marashal.ReleaseComObject(application) } Or if I need to release every single object created, as in this method: public void CreateExcelWorkbookWithSingleSheet() { var application = new ApplicationClass(); var workbook = application.Workbooks.Add(_missing); var worksheets = workbook.Worksheets; for (var worksheetIndex = 1; worksheetIndex < worksheets.Count; worksheetIndex++) { var worksheet = (WorksheetClass)worksheets[worksheetIndex]; worksheet.Delete(); Marshal.ReleaseComObject(worksheet); } workbook.SaveAs( WorkbookPath, _missing, _missing, _missing, _missing, _missing, XlSaveAsAccessMode.xlExclusive, _missing, _missing, _missing, _missing, _missing); workbook.Close(true, _missing, _missing); application.Quit(); Marshal.ReleaseComObject(worksheets); Marshal.ReleaseComObject(workbook); Marshal.ReleaseComObject(application); } What prompted me to ask this question is that, being the LINQ devotee I am, I really want to do something like this: var worksheetNames = worksheets.Cast<Worksheet>().Select(ws => ws.Name); ...but I'm concerned I'll end up with memory leaks or ghost processes if I don't release each worksheet (ws) object. Any insight on this would be appreciated.

    Read the article

< Previous Page | 15 16 17 18 19 20 21 22 23 24 25 26  | Next Page >