  • objdump -S - source code listing

    - by anon
    How does objdump manage to display source code? Is there a reference to the source file in the binary? I tried running strings on the binary and couldn't find any reference to the source file listed... Thanks.

    Read the article

  • How to find a function of application with ollydbg?

    - by user3725506
    Let's say i released the application below. using System; using System.Collections.Generic; using System.ComponentModel; using System.Data; using System.Drawing; using System.Linq; using System.Text; using System.Threading.Tasks; using System.Windows.Forms; namespace WindowsFormsApplication2 { public partial class Form1 : Form { public Form1() { InitializeComponent(); } private void button1_Click(object sender, EventArgs e) { MessageBox.Show("Hello World!","Message Box"); } } } Now here is my questions: How to find the function of button which is responsible to show message box after pressing the button with ollydbg? How to disable the button click ? Notes:this must be done with ollydbg only. Assume that i don't have access to the code. A step-by-step example would be greatly appreciated.

    Read the article

  • SpinRite and USB blues - does a solution exist?

    - by Peter Mortensen
    I use SpinRite to recover hard disks and their content, and to a lesser degree for preventive maintenance. However, if a USB drive (USB thumb drive and/or external hard disk with a USB interface) is connected when SpinRite scans for devices, then SpinRite never finishes/hangs. The work-around is of course to disconnect the drive, but there is value in being able to use SpinRite on USB drives. Some external drives have no screws and it is difficult to take out the hard disk without damaging the casing. And for those that have it would save the disassembling time. Is there a way to fix this problem (e.g. BIOS changes or a modified SpinRite boot CD) without resorting to floppy disks?

    Read the article

  • CPU fan twitching phase leds blinking - computer won't boot

    - by SooX
    I have a big problem that I got today. Yesterday computer was "on" normally, I went to sleep without shutting it down. When I woke up, I heard a strange sound and was unable to bring it up from hibernate. I unplugged the PSU. When I plugged the PSU back in, the sound came back. When I opened the case, I saw the fan "twitching" like it is about to start and fan LEDs were blinking. Also, motherboard LEDs were blinking in the same pattern - the first green one has more of luminosity then others. When I cut down the power with 0/1 button on PSU, the fans continue to make sounds like the machine is trying to boot before the capacitors run out and the power dies. Does anyone have a clue what to do? I tried disassembling everything but that doesn't work. I will try with friend's PSU later today.

    Read the article

  • Black spray (?) on a laptop's heat sink assembly

    - by arnehehe
    We have a HP Pavilion DV3 4000SB that was given an error on startup that the fan was having problems (System Fan 90b error message) So I decided to open the laptop up and clean the fan, as that seemed the easiest option. Upon opening it up, at first I froze and thought "No wonder! The whole thing's burnt!", but then I started thinking it looked more like someone used a spraycan on it. I looked up a video on youtube of someone disassembling his Pavilion and noticed there wasn't any of the black on his, so my question here is: Have any of you encountered this, or know what it is? Or if it's something that could point to a problem?

    Read the article

  • Can UMDF drivers be packaged/shipped via WiX?

    - by Rafael Rivera
    Howdy Internets: I put together a WiX 3.0 package, utilizing the DIFx extensions, with the intentions to install a Windows 7 Sensor (UMDF driver). During installation, DIFXAPP logged "No matching devices found in INF" and simply threw the driver into storage. I read I'm to populate my INF with an appropriate DriverPackageType, but according to MSDN's enumerated list, nothing fits. Is UMDF driver installation a supported scenario? If not, what's the best practice for using WiX to install such drivers? Disassembling the DIfx extension shows intent to support Co-installer packages, I have yet to try 3.5 beta.

    Read the article

  • BizTalk Server Threading in Receive Pipelines

    - by ToxicAvenger
    I am building custom pipeline components for receive pipelines in BizTalk Server (2006 and 2009). I am building the components in a streaming fashion. My question: for any single inbound message, if I have a disassembling component, when I create n messages from a single inbound message, will the message agent always use a single thread when reading the (body) streams and persisting the messages to the message box? I would think so, but confirmation would be helpful. Say if I create five messages in the disassembler, will any of these messages be persisted sequentially from the same thread? Or could these messages be processed in parallel?

    Read the article

  • Why do virtual memory addresses for linux binaries start at 0x8048000?

    - by muteW
    Disassembling an ELF binary on a Ubuntu x86 system I couldn't help but notice that the code(.text) section starts from the virtual address 0x8048000 and all lower memory addresses seem to be unused. This seems to be rather wasteful and all Google turns up is either folklore involving STACK_TOP or protection against null-pointer dereferences. The latter case looks like it can be fixed by using a single page instead of leaving a 128MB gap. So my question is this - is there a definitive answer to why the layout has been fixed to these values or is it just an arbitrary choice?

    Read the article

  • Could replacing an old hard drive's circuit board make it work again?

    - by oscilatingcretin
    I have a 12-year-old, 10gb Maxtor drive that died on me around 7 years ago, but I have not had the heart to throw it away. When the computer powers on, it whirrs silently as it tries to spin up and then it stops. So, a few years ago, I sent it off for professional data recovery. They were able to retrieve quite a bit from it, but I know there's a bunch more there. It only cost $700, so I just chalked up the lackluster recovery effort to "you get what you pay for" considering that most companies will charge you several thousands of dollars for this kind of data recovery. When they sent the drive back, I couldn't help but plug it back in just to see if maybe they unjammed something in the process of disassembling/reassembling the drive. To my surprise, the drive had a much healthier spin-up sound and actually stayed spinning for several minutes before winding down to a halt. Windows is even able to detect and interact with the drive, but I get I/O errors after so many minutes of waiting for it to mount. Before I start doing stupid stuff with it like dropping it on the ground, freezing it, crapping on it, etc, I decided to buy the exact same model off Ebay so that I could swap the circuit boards as a last-ditch effort. While it's en route, I thought I'd come here to ask if this is even a worthwhile effort and, if even remotely so, what should I know before ripping off the old board and slapping on the new?

    Read the article

  • BizTalk 2009 - Pipeline Component Wizard

    - by Stuart Brierley
    Recently I decided to try out the BizTalk Server Pipeline Component Wizard when creating a new pipeline component for BizTalk 2009. There are different versions of the wizard available, so be sure to download the appropriate version for the BizTalk environment that you are working with. Following the download and expansion of the zip file, you should be left with a Visual Studio solution.  Open this solution and build the project. Following this installation is straight foward - locate and run the built setup.exe file in the PipelineComponentWizard Setup project and click through the small number of installation screens. Once you have completed installation you will be ready to use the wizard in Visual Studio to create your BizTalk Pipeline Component. Start by creating a new project, selecting BizTalk Projects then BizTalk Server Pipeline Component.  You will then be presented with the splash screen. The next step is General Setup, where you will detail the classname, namespace, pipeline and component types, and the implementation language for your Pipeline Component. The options for pipeline type are Receive, Send or Any. Depending on the pipeline type chosen there are different options presented for the component type, matching those available within the BizTalk Pipelines themselves: Receive - Decoder, Disassembling Parser, Validate, Party Resolver, Any. Send -  Encoder, Assembling Serializer, Any. Any - Any. The options for implementation language are C# or VB.Net Next you must set up the UI settings - these are the settings that affect the appearance of the pipeline component within Visual Studio. You must detail the component name, version, description and icon.  Next is the definition of the variables that the pipeline component will use.  The values for these variables will be defined in Visual Studio when creating a pipeline. The options for each variable you require are: Designer Property - The name of the variable. Data Type - String, Boolean, Integer, Long, Short, Schema List, Schema With None Clicking finish now will complete the wizard stage of the creation of your pipeline component. Once the wizard has completed you will be left with a BizTalk Server Pipeline Component project containing a skeleton code file for you to complete.   Within this code file you will mainly be interested in the execute method, which is left mostly empty ready for you to implement your custom pipeline code:          #region IComponent members         /// <summary>         /// Implements IComponent.Execute method.         /// </summary>         /// <param name="pc">Pipeline context</param>         /// <param name="inmsg">Input message</param>         /// <returns>Original input message</returns>         /// <remarks>         /// IComponent.Execute method is used to initiate         /// the processing of the message in this pipeline component.         /// </remarks>         public Microsoft.BizTalk.Message.Interop.IBaseMessage Execute(Microsoft.BizTalk.Component.Interop.IPipelineContext pc, Microsoft.BizTalk.Message.Interop.IBaseMessage inmsg)         {             //             // TODO: implement component logic             //             // this way, it's a passthrough pipeline component             return inmsg;         }         #endregion Once you have implemented your custom code, build and compile your Custom Pipeline Component then add the compiled .dll to C:\Program Files\Microsoft BizTalk Server 2009\Pipeline Components . When creating a new pipeline, in Visual Studio reset the toolbox and the custom pipeline component should appear ready for you to use in your Biztalk Pipeline. Drop the pipeline component into the relevant pipeline stage and configure the component properties (the variables defined in the wizard). You can now deploy and use the pipeline as you would any other custom pipeline.

    Read the article

  • Is Cloud Security Holding Back Social SaaS?

    - by Mike Stiles
    The true promise of social data co-mingling with enterprise data to influence and inform social marketing (all marketing really) lives in cloud computing. The cloud brings processing power, services, speed and cost savings the likes of which few organizations could ever put into action on their own. So why wouldn’t anyone jump into SaaS (Software as a Service) with both feet? Cloud security. Being concerned about security is proper and healthy. That just means you’re a responsible operator. Whether it’s protecting your customers’ data or trying to stay off the radar of regulatory agencies, you have plenty of reasons to make sure you’re as protected from hacking, theft and loss as you can possibly be. But you also have plenty of reasons to not let security concerns freeze you in your tracks, preventing you from innovating, moving the socially-enabled enterprise forward, and keeping up with competitors who may not be as skittish regarding SaaS technology adoption. Over half of organizations are transferring sensitive or confidential data to the cloud, an increase of 10% over last year. With the roles and responsibilities of CMO’s, CIO’s and other C’s changing, the first thing you should probably determine is who should take point on analyzing cloud software options, providers, and policies. An oft-quoted Ponemon Institute study found 36% of businesses don’t have a cloud security policy at all. So that’s as good a place to start as any. What applications and data are you comfortable housing in the cloud? Do you have a classification system for data that clearly spells out where data types can go and how they can be used? Who, both internally and at the cloud provider, will function as admins? What are the different levels of admin clearance? Will your security policies and procedures sync up with those of your cloud provider? The key is verifiable trust. Trust in cloud security is actually going up. 1/3 of organizations polled say it’s the cloud provider who should be responsible for data protection. And when you look specifically at SaaS providers, that expectation goes up to 60%. 57% “strongly agree” or “agree” there’s more confidence in cloud providers’ ability to protect data. In fact, some businesses bypass the “verifiable” part of verifiable trust. Just over half have no idea what their cloud provider does to protect data. And yet, according to the “Private Cloud Vision vs. Reality” InformationWeek Report, 82% of organizations say security/data privacy are one of the main reasons they’re still holding the public cloud at arm’s length. That’s going to be a tough position to maintain, because just as social is rapidly changing the face of marketing, big data is rapidly changing the face of enterprise IT. Netflix, who’s particularly big on the benefits of the cloud, says, "We're systematically disassembling the corporate IT components." An enterprise can never realize the full power of big data, nor get the full potential value out of it, if it’s unwilling to enable the integrations and dataset connections necessary in the cloud. Because integration is called for to reduce fragmentation, a standardized platform makes a lot of sense. With multiple components crafted to work together, you’re maximizing scalability, optimization, cost effectiveness, and yes security and identity management benefits. You can see how the incentive is there for cloud companies to develop and add ever-improving security features, making cloud computing an eventual far safer bet than traditional IT. @mikestilesPhoto: stock.xchng

    Read the article

  • GCC/X86, Problems with relative jumps

    - by Ian Kelly
    I'm trying to do a relative jump in x86 assembly, however I can not get it to work. It seems that for some reason my jump keeps getting rewritten as an absolute jump or something. A simple example program for what I'm trying to do is this: .global main main: jmp 0x4 ret Since the jmp instruction is 4 bytes long and a relative jump is offset from the address of the jump + 1, this should be a fancy no-op. However, compiling and running this code will cause a segmentation fault. The real puzzler for me is that compiling it to the object level and then disassembling the object file shows that it looks like the assembler is correctly doing a relative jump, but after the file gets compiled the linker is changing it into another type of jump. For example if the above code was in a file called asmtest.s: $gcc -c asmtest.s $objdump -D asmtest.o ... Some info from objdump 00000000 <main>: 0: e9 00 00 00 00 jmp 5 <main+0x5> 5: c3 ret This looks like the assembler correctly made a relative jump, although it's suspicious that the jmp instruction is filled with 0s. I then used gcc to link it then disassembled it and got this: $gcc -o asmtest asmtest.o $objdump -d asmtest ...Extra info and other disassembled functions 08048394 <main>: 8048394: e9 6b 7c fb f7 jmp 4 <_init-0x8048274> 8048399: c3 ret This to me looks like the linker rewrote the jmp statement, or substituted the 5 in for another address. So my question comes down to, what am I doing wrong? Am I specifying the offset incorrectly? Am I misunderstanding how relative jumps work? Is gcc trying to make sure I don't do dangerous things in my code?

    Read the article

  • Fluent NHibernate no data being returned

    - by czuroski
    Hello, I have been successfully using NHibernate, but now I am trying to move to Fluent NHibernate. I have created all of my mapping files and set up my session manager to use a Fluent Configuration. I then run my application and it runs successfully, but no data is returned. There are no errors or any indication that there is a problem, but nothing runs. when using NHibernate, if I don't set my hbm xml files as an embedded resource, this same thing happens. This makes me wonder what I have to set my Map classes to. Right now, they are just set to Compile, and they are compiled into the dll, which I can see by disassembling it. Does anyone have any thoughts as to what may be happening here? Thanks private ISessionFactory GetSessionFactory() { return Fluently.Configure() .Database( IfxOdbcConfiguration .Informix1000 .ConnectionString("Provider=Ifxoledbc.2;Password=mypass;Persist Security Info=True;User ID=myuser;Data Source=mysource") .Dialect<InformixDialect1000>() .ProxyFactoryFactory<ProxyFactoryFactory>() .Driver<OleDbDriver>() .ShowSql() ) .Mappings( m => m.FluentMappings .AddFromAssemblyOf<cmCase>() .AddFromAssemblyOf<attorney>() .AddFromAssemblyOf<creditor>() .AddFromAssemblyOf<party>() .AddFromAssemblyOf<person>() .AddFromAssemblyOf<sardbk>() .AddFromAssemblyOf<schedule>() //x => x.FluentMappings.AddFromAssembly(System.Reflection.Assembly.GetExecutingAssembly()) //.ExportTo("C:\\mappings") ) .BuildSessionFactory(); }

    Read the article

  • Toshiba Satellite L630 broken after bios update

    - by Mustafa Kamal
    I have Toshiba Satellite L630, which has been broken. It had no more OS installed in it. All the disk partition were cleared into one single empty unformatted partition. So I begin to install windows XP on this laptop. Apparently, win XP's driver support for this laptop is very limited. So I have to find almost all important driver (display, sound, etherned, wireless etc) on the net and install it manually one by one. So I start googling, and I got some driver download page from several Toshiba's website (the global version, the europe, asia, etc). Pretty hard to find the exact drivers, but I managed to find pretty good drivers. It's all works quite fine, although still have a few glitches. But everything turned into a big mess when I downloaded the "BIOS Update", which is also listed on Toshiba's official driver directory site. When I installed it, it show a big red warning sign telling me not to do anything while flashing the BIOS . I follow that instruction prudently. The process was finished, and that update BIOS software (it is InsydeH2O BIOS) told me that the BIOS has been succesfully updated and the computer need to restart. So I restart the computer. This is where the problem appear. I can no longer boot to my laptop. The booting process seems to be able to enter windows for a moment (it shows the windows XP loading screen), and then suddenly it just got that hateful blue screen and then instantiy restarts the machine. It goes on a loop. Boot bios - enter XP - blue screen - restart. I can't even try to reinstall my win XP again. Evertime the machine tries to boot to win XP CD, it got the same blue screen as I gets when loading from HDD. Many google search results said that I should open the laptop cover and try to clear CMOS with some kind of jumper or something. Or to unplug/re-plug the CMOS battery. Do I really need to do that? Is there anyway I could do without disassembling my laptop? I read some tricks about booting from USB device but I can't get the exat tools that I need to do that thing... Btw, this is my detailed laptop number photographed from the back of my laptop

    Read the article

  • Why enumerator structs are a really bad idea

    - by Simon Cooper
    If you've ever poked around the .NET class libraries in Reflector, I'm sure you would have noticed that the generic collection classes all have implementations of their IEnumerator as a struct rather than a class. As you will see, this design decision has some rather unfortunate side effects... As is generally known in the .NET world, mutable structs are a Very Bad Idea; and there are several other blogs around explaining this (Eric Lippert's blog post explains the problem quite well). In the BCL, the generic collection enumerators are all mutable structs, as they need to keep track of where they are in the collection. This bit me quite hard when I was coding a wrapper around a LinkedList<int>.Enumerator. It boils down to this code: sealed class EnumeratorWrapper : IEnumerator<int> { private readonly LinkedList<int>.Enumerator m_Enumerator; public EnumeratorWrapper(LinkedList<int> linkedList) { m_Enumerator = linkedList.GetEnumerator(); } public int Current { get { return m_Enumerator.Current; } } object System.Collections.IEnumerator.Current { get { return Current; } } public bool MoveNext() { return m_Enumerator.MoveNext(); } public void Reset() { ((System.Collections.IEnumerator)m_Enumerator).Reset(); } public void Dispose() { m_Enumerator.Dispose(); } } The key line here is the MoveNext method. When I initially coded this, I thought that the call to m_Enumerator.MoveNext() would alter the enumerator state in the m_Enumerator class variable and so the enumeration would proceed in an orderly fashion through the collection. However, when I ran this code it went into an infinite loop - the m_Enumerator.MoveNext() call wasn't actually changing the state in the m_Enumerator variable at all, and my code was looping forever on the first collection element. It was only after disassembling that method that I found out what was going on The MoveNext method above results in the following IL: .method public hidebysig newslot virtual final instance bool MoveNext() cil managed { .maxstack 1 .locals init ( [0] bool CS$1$0000, [1] valuetype [System]System.Collections.Generic.LinkedList`1/Enumerator CS$0$0001) L_0000: nop L_0001: ldarg.0 L_0002: ldfld valuetype [System]System.Collections.Generic.LinkedList`1/Enumerator EnumeratorWrapper::m_Enumerator L_0007: stloc.1 L_0008: ldloca.s CS$0$0001 L_000a: call instance bool [System]System.Collections.Generic.LinkedList`1/Enumerator::MoveNext() L_000f: stloc.0 L_0010: br.s L_0012 L_0012: ldloc.0 L_0013: ret } Here, the important line is 0002 - m_Enumerator is accessed using the ldfld operator, which does the following: Finds the value of a field in the object whose reference is currently on the evaluation stack. So, what the MoveNext method is doing is the following: public bool MoveNext() { LinkedList<int>.Enumerator CS$0$0001 = this.m_Enumerator; bool CS$1$0000 = CS$0$0001.MoveNext(); return CS$1$0000; } The enumerator instance being modified by the call to MoveNext is the one stored in the CS$0$0001 variable on the stack, and not the one in the EnumeratorWrapper class instance. Hence why the state of m_Enumerator wasn't getting updated. Hmm, ok. Well, why is it doing this? If you have a read of Eric Lippert's blog post about this issue, you'll notice he quotes a few sections of the C# spec. In particular, 7.5.4: ...if the field is readonly and the reference occurs outside an instance constructor of the class in which the field is declared, then the result is a value, namely the value of the field I in the object referenced by E. And my m_Enumerator field is readonly! Indeed, if I remove the readonly from the class variable then the problem goes away, and the code works as expected. The IL confirms this: .method public hidebysig newslot virtual final instance bool MoveNext() cil managed { .maxstack 1 .locals init ( [0] bool CS$1$0000) L_0000: nop L_0001: ldarg.0 L_0002: ldflda valuetype [System]System.Collections.Generic.LinkedList`1/Enumerator EnumeratorWrapper::m_Enumerator L_0007: call instance bool [System]System.Collections.Generic.LinkedList`1/Enumerator::MoveNext() L_000c: stloc.0 L_000d: br.s L_000f L_000f: ldloc.0 L_0010: ret } Notice on line 0002, instead of the ldfld we had before, we've got a ldflda, which does this: Finds the address of a field in the object whose reference is currently on the evaluation stack. Instead of loading the value, we're loading the address of the m_Enumerator field. So now the call to MoveNext modifies the enumerator stored in the class rather than on the stack, and everything works as expected. Previously, I had thought enumerator structs were an odd but interesting feature of the BCL that I had used in the past to do linked list slices. However, effects like this only underline how dangerous mutable structs are, and I'm at a loss to explain why the enumerators were implemented as structs in the first place. (interestingly, the SortedList<TKey, TValue> enumerator is a struct but is private, which makes it even more odd - the only way it can be accessed is as a boxed IEnumerator!). I would love to hear people's theories as to why the enumerators are implemented in such a fashion. And bonus points if you can explain why LinkedList<int>.Enumerator.Reset is an explicit implementation but Dispose is implicit... Note to self: never ever ever code a mutable struct.

    Read the article