Search Results

Search found 53 results on 3 pages for 'jbod'.

Page 2/3 | < Previous Page | 1 2 3  | Next Page >

  • Mac Pro Boot Camp w/ RAID card

    - by churnd
    If I configure a Mac Pro with a RAID card and two 15k RPM drives, and leave the drives JBOD (no RAID configured), can I install Windows on the second drive? I guess the question really is, does Windows recognize the RAID card? I know it's probably just a rebadged LSI or Adaptec but wanted to see if anyone's actually done it...

    Read the article

  • Do 7.2k SATA drives and a hardware raid controller always end with trouble?

    - by xelco52
    I'm reading the FreeNAS userguide and came across the statement: Note that hardware RAID configured as JBOD may still detach disks that do not respond in time; and as such may require TLER/CCTL/ERC-enabled disks to prevent drive dropouts. I'm using a '3Ware 9550SX-8LP RAID Controller' and see quite a few stories of people successfully running raid5 on 7.2k consumer SATA drives without issue. Are detached disks only a theoretical problem, or should I expect this to be a common occurrence?

    Read the article

  • Drives will not show up on PCI RAID card in Ubuntu 12.04 LTS

    - by Mechh69
    Computer specs Intel E8200 Dual Core MSI G45M MB Ultra U12-40739 PCI Expansion Card - 2 SATA Internal Ports, 1.5Gbps, RAID 0, 1, JBOD 6 GB DDR2 Q1. I installed Ubuntu 12.04 LTS and Amahi, for using Grey Hole, last night. The two disc on the raid card do not show up under Ubuntu 12.04LTS but they do show up under grey hole so I know the drives and the raid card are working and there. I need to access them in Ubuntu to format them and place folders on them but I can not see them or figure out how to access them. Q2. Only 4 of the six drives connected to the MB are showing in Ubuntu, but they show as active in grey hole. I also need to access these drives in Ubuntu as this is my storage server. I am new to LINUX so any help you can provide with simple directions will be greatly appreciated . Thank you Mechh69

    Read the article

  • Home ZFS based NAS...What processor/chipset to use?

    - by MrBlargityBlarg
    So, I'm building a home/personal NAS. My plan is to expose both SMB fileshares for sharing files/media between hosts, but also to carve an iSCSI target LUN out of it for use by VMWare as a datastore. I want to use ZFS (software RAID) so that means I'll either be using FreeNAS, Solaris Express, or OpenIndiana. My question is basically: How much horsepower do I need? Obviously I/O is going to be my bottleneck but I want to be sure that I am not limiting my I/O because of a slow processor or chipset. So far the hardware plan is to use an Intel i3 and motherboard with one of the H87, Q87, or Z87 chipsets, a SAS controller (JBOD, no RAID) and if budget allows, I'm also hoping to get an SSD for the ZFS L2ARC and ZIL. Does anyone think I could get away with an Intel Atom or cheaper/less-capable processor/chipset than the i3 and [HQZ]87 listed above?

    Read the article

  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS storage solutions. In addition, what effect does battery-backed write cache (BBWC) have in ZFS storage?

    Read the article

  • Practical RAID Performance?

    - by wag2639
    I've always thought the following to be a general rule of thumb for RAID: RAID 0: Best performance for READ and WRITE from stripping, greatest risk RAID 1: Redundant, decent for READ (I believe it can read from different parts of a file from different hard drives), not the best for WRITE RAID 0+1 (01): combines redundancy of RAID 1 with performance of RAID 0 RAID 1+0 (10): slightly better version of RAID 0+1 RAID 5: good READ performance, bad WRITE performance, redundant IS THIS ASSUMPTION CORRECT? (and how do they compare to a JBOD setup for R/W IO performance) Are certain practical RAID setups better for different applications: gaming, video editing, database (Acccess or SQL)? I was thinking about hard disk drives but does this apply to solid state drives as well?

    Read the article

  • Advantage of using nexenta vs. OpenSolaris

    - by jotango
    I am currently building a NAS for about 24 TB of storage. Video files, slow access, long term storage. No performance issues. I am currently undecided between buying a JBOD case and installing OpenSolaris (because of ZFS), or purchasing a Nexenta license. The difference is about $ 12.500 for licenses over three years. What would you see as the main advantage in purchasing a nexenta license, beside the support? Did nexenta really enhance the basic OpenSolaris, or is it just a lot of marketing speak? No one really wanted to answer that question.

    Read the article

  • Can I move a one drive RAID 0 array on a PERC 6 to another server?

    - by zippy
    We have a Dell Poweredge 2970 with a PERC 6/i RAID controller. We have a one drive RAID 0 array (we wanted to add the drive as a JBOD but the PERC forces you to create an array to access it from the PERC). Can we take the one drive RAID 0 and move it to a new server (one that doesn't have a PERC)? Since there's only one drive in the "array" there's no striping going on...the only issue would seem to be if the PERC has some metadata on the drive that would prevent Windows from reading it. Does anyone have any experience with this scenario?

    Read the article

  • insert system disk error after switchting SATA cables

    - by Matthias
    I have 5 hard disks built in my computer, two connected by IDE cables, three by SATA. Today I had to return two of the SATA cables to my room mate. So I grabbed another one I had floating around and connected the remaining disk by unplugging my DVD R/W. Now I receive the 'insert system disk and press enter' error after booting. Disks and cables seem to be fine, since all the disks are recognized in the BIOS. Also, I can mount the disks using a live CD w/o problems. I also tried different orderings of the cables (i.e. plugging the disks in different plugs on the mainboard), I'm not sure if that even matters using SATA. Any Ideas what might be the problem here? The OS installed are Windows 7 and Ubuntu 10, the bootloader installed is GRUB. PS: No RAID involved, JBOD.

    Read the article

  • Windows 2008 as home file server and more

    - by Christian W
    I currently have a freenas-unit as a NAS, and a Win2k8R2-unit as server. However I would like to consolidate these to units in one. What I really like about the freenas-unit is the ZFS filesystem. And the only reason I care about the ZFS filesystem is the easy way I can grow an existing filesystem just by inserting a new drive. How would this work in Win2k8? If I setup my unit with a separate drive as C: and a 1TB drive as D:. The D: would then be segmented into d:\Videos d:\Music d:\Pictures. When everything gets close to filling the storage-drive, I would like to expand the storage, but I wouldn't want to have E:\Videos or d:\Videos2 (using the NTFS folder mount thingy). I still want all my Videos to reside in D:\Videos and I want the OS to decide which drive it's going to be stored on... Some kind of on-the-fly jbod expansion :) Is this at all possible in Windows 2008?

    Read the article

  • Achieving/maxing out 1GBPS connectivity on a nginx server

    - by Ansell Cruz
    This page (http://www.remsys.com/nginx-on-1gbps) claims that it can max out a 1gbps line using JBOD setup and no raid. Currently I'm on a 1gbps dedicated port and I'm on raid 10 (4x2TB - the disks that comes with 100tb.com servers). Currently I'm only peaking at 500-550mbps. wa% would show something around 20% everytime. I'm looking into maxing out this 1gbps port because I have an unmetered service from them. Do you guys think that the page that I referenced would be better than my current raid setup? Do you guys have any other suggestions on how to max out the performance of this server? TYI.

    Read the article

  • ZFS SAS/SATA controller recommendations

    - by ewwhite
    I've been working with OpenSolaris and ZFS for 6 months, primarily on a Sun Fire x4540 and standard Dell and HP hardware. One downside to standard Perc and HP Smart Array controllers is that they do not have a true "passthrough" JBOD mode to present individual disks to ZFS. One can configure multiple RAID 0 arrays and get them working in ZFS, but it impacts hotswap capabilities (thus requiring a reboot upon disk failure/replacement). I'm curious as to what SAS/SATA controllers are recommended for home-brewed ZFS JBODs. In addition, how does battery-backed write cache (BBWC) play into the solution?

    Read the article

  • RAID 5 heavy IO hard freezes Ubuntu: Why?

    - by Luke has no name
    I have a software RAID 5 partition on LVM in Ubuntu (desktop, actually, but I'm using it as a server). I have been rsyncing a ton of data to it, and the computer was hard freezing, as in I needed to press "Reset". So I thought it was rsync. But I decided I'd try a dd if=/dev/zero of=/path/to/raid5 and sure enough, the computer locked up. Did an identical dd to a JBOD partition on the same machine, and it didn't crash. Assuming a clean RAID5 partition, tri-core processor 2GB of ram, 6GB swap, what could be causing this?

    Read the article

  • How to disable the RAID in x3400 M2

    - by BanKtsu
    Hi I just wanna disable the default RAID in my server IBM System X3400 M2 Server(7837-24X),i have 3 disk drives SAS. I want to make them a JBOD "Just a Bunch Of Disks", because I want to install in the drive 0 CentOS, and the other two make them cache files for a squid server. I disable the RAID in the BIOS: System Settings/Adapters and UEFI drivers/LSI Logic Fusion MPT SAS Driver -PciRoot(0x0)/Pci(0x3,0X0)/Pci(0x0,0x0) LSI Logic MPT Setup Utility RAID Properties/Delete Array Later I boot the CentOS live CD and install the OS in the drive 0, and the others 2 mounted like this: *LVM Volume Groups vg_proxyserver 139508 lv_root 51200 / ext4 lv_home 84276 /home ext4 lv_swap 4032 Hard Drive sdb(/dev/sdb) free 140011 sdc(/dev/sdc) free 140011 sdd(/dev/sdd) sdd1 500 /boot ext4 sdd2 139512 vg_proxyserver physical volume(LVM) But when I restart the server give me the error: Boot failed Hard Disk 0 UEFI PXE PciRoot(0x0)/Pci(0x1,0X0)/Pci(0x0,0x0)/MAC(001A64B15130,0X0)) ........PXE-E18:Server response timeout. UEFI PXE PciRoot(0x0)/Pci(0x1,0X0)/Pci(0x0,0x0)/MAC(001A64B15132,0X0)) ........PXE-E18:Server response timeout. and the OS not start. The IBM force me to do a RAID?,why?

    Read the article

  • gpfs: adding a new nsd server to a cluster

    - by alessandra
    I have a gpfs cluster composed by 10 linux nodes, managed by a primary server A, which also act as nsd server for a first stack of disks. I attached a new jbod to one of the nodes (call it node B), which I would like to become a nsd server for this new stack of disks, but still be included in the cluster so that the disks are available to all the nodes. Node B is connected to the cluster via ethernet. How can I make the new nsd seen by all the nodes of the cluster? I can create the new nsd but when trying to create the filesystem on node B it the command mmcrfs times out. It looks like the nodes of the cluster cannot understand the filesystem location even if I specify them attached to server B in the description file. Would it be better to remove node B from the cluster, create a cluster on its own with its attached filesystem and connect it remotely with the previous cluster? Or a clustered NFS solution would apply better? Can you please give me any suggestion?

    Read the article

  • Installing SATA dvd burner on machine with no spare SATA ports/connectors

    - by Faheem Mitha
    Greetings. I have the following motherboard Tyan Thunder K8WE S2895A2NRF Motherboard - extended ATX - nForce Pro 2200/2050 - Socket 940 - UDMA133, Serial ATA-300 (RAID) - 2 x Gigabit Ethernet - FireWire - 6-1 channel audio This is part of a computer that was assembled in the winter of 2006/2007. The user manual says the following with regard to SATA Integrated SATAII Generation 1 Controllers (from NForce Professional 2200) Two integrated dual port SATA II controllers Four SATA connectors support up to four drives 3 Gb/s per direction per channel NvRAID v2.0 support Supports RAID 0, 1, 0+1 and JBOD. I just purchased a SATA DVD burner. Here is the page for the product http://www.amazon.ca/gp/product/B002QGDWLK/ The problem I am facing is that I already have 4 SATA drives installed. I don't want to remove any of them. However, I want the DVD burner above installed as well. The person I am consulting with here (Bombay, India) tells me that my four available SATA ports are filled, and that my only option is to install a SATA card into the one free PCI slot on the motherboard. However, he says that with this setup I will not be able to boot from the DVD drive. Are these statements correct, and what are my other options if any? Even it the statements in the last para are true, I suppose I could use one of the motherboard connectors/ports there are currently being used with the hard drives with the DVD drive, and use the "add-on" connector with one of the hard drives. Not all the 4 hard drives need to be bootable. BTW, despite having read through http://en.wikipedia.org/wiki/Serial_ATA#Cables.2C_connectors.2C_and_ports I am fuzzy on the differences between connectors, cables and ports. Thanks in advance.

    Read the article

  • external drive enclosure -> software RAID 5?

    - by memilanuk
    Hello all, I have two older PCs on my LAN posing as 'servers'... one running FreeNAS off a USB stick using three 500GB hdds in a ZFS RAID-Z pool serving as storage for the LAN and one running Debian Lenny with an 80GB drive used as a general purpose 'tinker' box that I can ssh into, etc. Problem is that the SMART report for one of those 500GB drives in the FreeNAS box is showing some pre-failure attributes, and the whole array is a little small anyways. Rather than simply replace one 500GB drive with another 500GB drive, and have no backup of the file server, I'd like to upgrade all the drives to 2TB ones - but I have no where to store that much data in the mean while. As such, I started looking at getting a 4-bay external drive enclosure with an eSATA card for the Debian box, with the hopes of creating a RAID5 + LVM setup using those drives and backing the data up to that external drive enclosure. After the backup is done, replace the drives in the FreeNAS box and rebuild the array there and mirror the data back. Then, I'd have both the primary storage (on the FreeNAS box) and a backup (which I don't have currently) using the external drive enclosure on the Debian box. My big question is... most of these external drive boxes seem to claim support for JBOD, RAID 0, 1, 10, 5, etc. - should I presume that is simply fake RAID like many commodity mobos have, and not really usable in Linux? In that case, with all the drives hanging off the one eSATA connection, will Linux (specifically Debian Squeeze, as I plan on upgrading that box here shortly) see all four drives, or just the first one? Will I be able to configure them in a RAID5 array as desired? Thanks, Monte

    Read the article

  • Using mixed disks and OpenFiler to create RAID storage

    - by Cylindric
    I need to improve my home storage to add some resilience. I currently have four disks, as follows: D0: 500Gb (System, Boot) D1: 1Tb D2: 500Gb D3: 250Gb There's a mix of partitions on there, so it's not JBOD, but data is pretty spread out and not redundant. As this is my primary PC and I don't want to give up the entire OS to storage, my plan is to use OpenFiler in a VM to create a virtual SAN. I will also use Windows Software RAID to mirror the OS. Partitions will be created as follows: D0 P1: 100Mb: System-Reserved Boot D0 P2: 50Gb: Virtual Machine VMDKs for OS D0 P3: 350Gb: Data D1 P1: 100Mb: System-Reserved Boot D1 P2: 50Gb: Virtual Machine VMDKs for OS D1 P3: 800Gb: Data D2 P1: 450Gb: Data D3 P1: 200Gb: Data This will result in: Mirrored boot partition Mirrored Operating system Mirrored Virtual machine O/S disks Four partitions for data In the four data partitions I will create several large VMDK files, which I will "mount" into OpenFiler as block-storage devices, combined into three RAID arrays (due to the differing disk sizes) In effect, I'll end up with the following usable partitions SYSTEM 100Mb the small boot partition created by the Windows 7 installer (RAID-1) HOST 50Gb the Windows 7 partition (RAID-1) GUESTS 50Gb Virtual machine Guest VMDK's (RAID-1) VG1 900Gb Volume group consisting of a RAID-5 and two RAID-1 VG2 300Gb Volume group consisting of a single disk On VG1 I can dynamically assign storage for my media, photographs, documents, whatever, and it will be safe. On VG2 I can dynamically assign storage for my data that is not critical, and easily recoverable, as it is not safe. Are there any particular 'gotchas' when implementing a virtual OpenFiler like this? Is the recovery process for a failing disk going to be very problematic? Thanks.

    Read the article

  • 24TB RAID 6 configuration

    - by Phil
    I am in charge of a new website in a niche industry that stores lots of data (10+ TB per client, growing to 2 or 3 clients soon). We are considering ordering about $5000 worth of 3TB drives (10 in a RAID 6 configuration and 10 for backup), which will give us approximately 24 TB of production storage. The data will be written once and remain unmodified for the lifetime of the website, so we only need to do a backup one time. I understand basic RAID theory, however I am not experienced with it. My question is, does this sound like a good configuration? What potential problems could this setup cause? Also, what is the best way to do a one-time backup? Have two RAID 6 arrays, one for offsite backup and one for production? Or should I backup the RAID 6 production array to a JBOD? EDIT: The data server is running Windows 2008 Server x64. EDIT 2: To reduce rebuild time, what would you think about using two RAID 5's instead of one RAID 6?

    Read the article

  • Is current SATA 6 gb/s equipment simply unreliable?

    - by korkman
    I have a 45-disk array of Seagate Barracuda 3 TB ST3000DM001 (yes these are desktop drives I'm aware of that) in a Supermicro sc847 JBOD, connected via LSI 9285. I have found a solution for the problem description below by reducing speed via MegaCli -PhySetLinkSpeed -phy0 2 -a0; for i in $(seq 48); do MegaCli -PhySetLinkSpeed -phy${i} 2 -a0; done and rebooting. The question remains: Is this typical for current 6 gb/s equipment? Is this the sad state of SATA storage? Or is some of my equipment (the sff-8088 cables come to mind) bad? The Problem was: Synchronizing HW RAID-6, disks kept offlining. Fetching SMART values reveiled that those which offlined did not increase powered-on hours anymore. That is, their firmware (CC4C) seems to crash. Digging into the matter by switching to Software RAID-6, with the disks passed-through, I got tons of kernel messages scattered across all disks, with 6 gb/s: sd 0:0:9:0: [sdb] Sense Key : No Sense [current] Info fld=0x0 sd 0:0:9:0: [sdb] Add. Sense: No additional sense information And finally, when a disk offlines: megasas: [ 5]waiting for 160 commands to complete ... megasas: [35]waiting for 159 commands to complete ... megasas: [155]waiting for 156 commands to complete ... megaraid_sas: pending commands remain after waiting, will reset adapter. Ugly controller reset here, then minutes later: megaraid_sas: Reset successful. sd 0:0:28:0: Device offlined - not ready after error recovery ... sd 0:0:28:0: [sdu] Unhandled error code sd 0:0:28:0: [sdu] Result: hostbyte=DID_ERROR driverbyte=DRIVER_OK sd 0:0:28:0: [sdu] CDB: Read(10): 28 00 23 21 2f 40 00 00 70 00 sd 0:0:28:0: [sdu] killing request Reduced speed to 3 gb/s like written above, all problems vanished.

    Read the article

  • XenServer 5.5 running WHS.. trying to add local or network printer/scanner/copier

    - by ProstheticHead
    Hi guys. Just wondering if anyone has prior experience in sharing a multifunction printer across a (mostly windows) network? My situation at the minute is complicated.. I DID have the printer attached directly to a Windows Home Server box and was able to scan to a share and print across the network from my other computers. Compatibility problems have forced me to virtualize WHS on XenServer 5.5... This is actually quite useful because I can now run other things on the same box, but the problem is that now WHS doesn't get direct hardware access so it doesn't see a USB attached PSC... Grrrr! So now I have a choice to make. I've read somewhere that I can buy an add in PCI USB controller and somehow set up a passthrough to one VM at a time. To me, this sound complicated but if it's likely to work reliably I'd prefer this method. I've read about another approach, which I'm not sure about either, but I guess sounds plausible. A Network USB server, (NOT a print server) that can somehow make a USB port accessible across a network. My worry here is that it likely needs some kind of 3rd party software to work.. so not ideal. If there are any other methods you can suggest I'd be happy to hear them... I need your help guys. I'm also in the market for a PCI express SATA controller, nothing flashy, just need up to 8 ports, JBOD and 100% compatability.. Any suggestions? Regards Kevin

    Read the article

  • How to diagnose storage system scaling problems?

    - by Unknown
    We are currently testing the maximum sequential read throughput of a storage system (48 disks total behind two HP P2000 arrays) connected to HP DL580 G7 running RHEL 5 with 128 GB of memory. Initial testing has been mainly done by running DD-commands like this: dd if=/dev/mapper/mpath1 of=/dev/null bs=1M count=3000 In parallel for each disk. However, we have been unable to scale the results from one array (maximum throughput of 1.3 GB/s) to two (almost the same throughput). Each array is connected to a dedicated host bust adapter, so they should not be the bottleneck. The disks are currently in JBOD configuration, so each disk can be addressed directly. I have two questions: Is running multiple DD commands in parallel really a good way to test maximum read throughput? We have noticed very high SWAPIN-% numbers in iotop, which I find hard to explain because the target is /dev/null How shoud we proceed in trying to find the reason for the scaling problem? Do you thing the server itself is the bottleneck here, or could there be some linux parameters that we have overlooked?

    Read the article

  • FreeNAS pool configuration - RAID1 + other drives

    - by trnelson
    Simple questions, really. I found this answer with a similar setup, but not sure it answers my question. If it does, I'm curious why since the answer seems a bit unsure: ZFS Hard Drive Configuration in FreeNAS I'm building a server which will be used primarily for backup, plus some media streaming, possibly with Plex. I seem to understand most everything I need, but I'm still a bit confused on how pools work, and how to configure them for my scenario. I will have 2x 2TB WD Red drives, which I plan on using in a mirrored set up (RAID1). This would be for backup, and I'd also like to do offsite backup to my CrashPlan account from this array. I also have a few other drives: 1.5TB, 320GB, 250GB. I'm not sure exactly what to do with them yet, but looking for options. FreeNAS OS will be running from a 16GB USB Flash drive. Would it be wise to use the 1.5TB as a backup-backup, essentially as a mirror or perhaps for snapshots of the 2TB RAID1? I'm still learning about snapshots. Should the 2TB mirrored drives be in their own pool? Should the other drives be set up in their own pools as well, or should they be JBOD in a single pool? They may or may not get much use since the 2TB array is plenty for me. Does a dataset basically mimic the idea of a partition or a network share? In other words, I would map \SERVER\Share to X: on my laptop? Let's say I wanted to use the 250GB drive as an encrypted drive to store all of my cat pictures. Would it have to be in its own pool? If I use jails apps, should they go in the backup RAID1, or in another place? Thank you!

    Read the article

  • Server 2012 - transparent SMB failover without shared discs, possible?

    - by TomTom
    here is the scenario - there is a small set (200gb around) of data that I HAVE to keep available. Those are basically shared VHD images that serve as master images for a lot of our VM's - they then run in differential discs off those. The whole set is "mostly read only". In more detail: A file that IS there and IS used will NEVER change. I may delete files (when absolutely not in use) and add new files, but a file that is there once gets read protection set and that it is until it is retired. Obviously, I need as much uptime as possible. SO FAR we run that by having this directory local on every Hyper-V server. Now I think moving this into our storage fabric. Due to the "it HAS to be there" I pretty much want a share nothing architecture. DFS would be perfect for this - a file never changes, so replication would work nicely. Folders could be replicated to a number of servers, all would reference them from there. Now, that hyper-V supports SMB that could be a good idea to isolate these on a number of servers - we try to move into a scenario where the storage is more centralized. Server 2012 supports always on shares, but it seems that this only works with a clustered disc behind. Is there any way around this for read only file stores? All documentation points to stuff like a shared JBOD - but that would leave me open for file system corruption. I really plan to go quite separately here, vertically - 2 servers, both with SSD only for this, both with their own 2000W separate USV, both with enough bandwidth to handle everything thrown at them (note to everyone tinking this is 10G - this would be SLOW and EXPENSIVE compared to a nice Infiniband backbone). The real crux is that this is an edge case obviously - as the files are read only once in use.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

< Previous Page | 1 2 3  | Next Page >