Search Results

Search found 1106 results on 45 pages for 'lo wai lun'.

Page 2/45 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • iSCSI: LUNs per target?

    - by badnews
    My question relates specifically to ZFS/COMSTAR but I assume is generally applicable to any iSCSI system: Should one prefer to create a target for every LUN that you want to expose? Or is it good practise to have a single target with multiple LUNs? Does either approach have a performance impact? And is there some crossover point where the other approach makes sense? The use case is for VM disks, where each disk (zvol) is a LUN. So far we have created a a separate target for each VM; but a single target that contains all the LUNs would probably greatly simplify management... but we may need hundreds of LUNs per a single target. (And then possibly tens of initiator connections to that target)

    Read the article

  • Getting Partial / No Redundancy on VM's created on latest datastore

    - by Germano
    Hi, First some background. I'm in the process of upgrading my ESX servers from 3.5 to vSphere 4 and so far I have setup the new vCenter Server. Before I start the upgrade of the ESX, I needed more storage so I created 3 datastores from available space on my Equallogic PS6000 which has been connected for a while so as far as connectivity, nothing has changed. but now here's my problem, I get a "Partial / No Redundancy" on any VM that I create in any of these new datastores. I can create VM's on any of the older datstores on LUN's from exactly the same Equallogic and it works fine, but not the new ones. Keep in mind that these new datastores are the only ones that were created under the new vCenter, so I believe it must have something to do with it. Is anyone aware of any issues about creating datastored using the new vCenter but on a 3.5 ESX host? ISCSI with QLogic QLE406x Thanks in advance for nay help. Germano

    Read the article

  • Cannot extend existing data disk over 2TB on windows 2008 with dynamic and gpt part

    - by DJYod
    As my D: disk is almost full (2TB) I extended the FC lun to 2.5TB. The new 500Go are seen by windows as "Unalloacted" as expected. I tried to extend the volume but windows says "The is not enough space available on the disk(s) to complete this operation" I read on the web that the disk should be configured as GPT and as a dynamic and it's already a dynamic gpt disk... How can I extend my disk without any data loss? My operating system is Windows 2008 R2 x64 SP1 and the SAN a 3PAR I hope someone can help me :) Thank you very much

    Read the article

  • When querying the Win32_NTLogEvent Class from WMI with WQL is the TimeGenerated property based on Lo

    - by jpmcclung
    I am writing a C# windows service that is doing some churning through the eventlog on a few domain controllers. Some of them are Windows Server 2003 and some are Windows Server 2008. Upon the service stopping I am attempting to resume where I left off in the logs. In order to do this instead of SELECT * FROM Win32_NTLogEvent WHERE --criteria for events I am looking for I am doing SELECT * FROM Win32_NTLogEvent WHERE TimeGenerated = --some date AND --criteria for events I am looking for At one point I was convinced that the TimeGenerated field was in the local time of the server but now it seems that the Windows 2008 Servers are using GMT to record that time. Can anyone shed some light on if this is a real different between the way the two operating systems function or is this a configuration problem?

    Read the article

  • NHibernate Hi-Lo

    - by cvista
    Yo Quick q: are Nhibernate HiLo ids unique accross the DB? The reason I ask is that we have multiple entities which have an image associated with them. On the client - I am simply storing these images in a folder using the enity ID as the name - am I going to trip over doing this? w://

    Read the article

  • Calling UIGetScreenImage() on manually-spawned thread prints "_NSAutoreleaseNoPool():" message to lo

    - by jtrim
    This is the body of the selector that is specified in NSThread +detachNewThreadSelector:(SEL)aSelector toTarget:(id)aTarget withObject:(id)anArgument NSAutoreleasePool *pool = [[NSAutoreleasePool alloc] init]; while (doIt) { if (doItForSure) { NSLog(@"checking"); doItForSure = NO; (void)gettimeofday(&start, NULL); /* do some stuff */ // the next line prints "_NSAutoreleaseNoPool():" message to the log CGImageRef screenImage = UIGetScreenImage(); /* do some other stuff */ (void)gettimeofday(&end, NULL); elapsed = ((double)(end.tv_sec) + (double)(end.tv_usec) / 1000000) - ((double)(start.tv_sec) + (double)(start.tv_usec) / 1000000); NSLog(@"Time elapsed: %e", elapsed); [pool drain]; } } [pool release]; Even with the autorelease pool present, I get this printed to the log when I call UIGetScreenImage(): 2010-05-03 11:39:04.588 ProjectName[763:5903] *** _NSAutoreleaseNoPool(): Object 0x15a2e0 of class NSCFNumber autoreleased with no pool in place - just leaking Has anyone else seen this with UIGetScreenImage() on a separate thread?

    Read the article

  • How to completely disable IPv6 for loopback interface on RHEL 5.6

    - by Marc D
    I've done lots of research on how to disable IPv6 on RedHat Linux and I have it almost completely disabled. However the loopback interface is still getting an inet6 loopback address (::1/128). I can't find where IPV6 is still enabled for loopback. To disable IPV6 I added the following settings to /etc/sysctl.conf: net.ipv6.conf.default.disable_ipv6=1 net.ipv6.conf.all.disable_ipv6=1 And also added the following line to /etc/sysconfig/network: NETWORKING_IPV6=no After rebooting, the inet6 address is gone from my physical interface (eth0), but is still there for lo: # ip addr show 1: lo: <LOOPBACK,UP,LOWER_UP> mtu 16436 qdisc noqueue link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 inet 127.0.0.1/8 scope host lo inet6 ::1/128 scope host valid_lft forever preferred_lft forever 2: eth0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast qlen 1000 link/ether 00:50:56:xx:xx:xx brd ff:ff:ff:ff:ff:ff inet 10.x.x.x/21 brd 10.x.x.x scope global eth0 If I manually remove the IPV6 address from loopback and then bounce the interface, it comes back: # ip addr del ::1/128 dev lo # ip addr show lo 1: lo: <LOOPBACK,UP,LOWER_UP> mtu 16436 qdisc noqueue link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 inet 127.0.0.1/8 scope host lo # ip link set lo down # ip link set lo up # ip addr show lo 1: lo: <LOOPBACK,UP,LOWER_UP> mtu 16436 qdisc noqueue link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 inet 127.0.0.1/8 scope host lo inet6 ::1/128 scope host valid_lft forever preferred_lft forever I believe IPV6 should be disabled at the kernel level as confirmed by sysctl: # sysctl net.ipv6.conf.lo.disable_ipv6 net.ipv6.conf.lo.disable_ipv6 = 1 Any ideas on what else would cause the loopback interface to get an IPV6 address?

    Read the article

  • LUNs disappear after rebooting the ESX/ESXi host

    - by mariolos
    A single LUN among from a group disappeared. Neither the host nor the Vcenter can see it. Four virtual machines on the LUN now are unknown. The strange thing is the LUN is now available in the list when you try to ADD datastore from configuration == storage == Add Datastore But this cannot help me since i need the vms on the lun and i do not get options to add the lun without formating it to VMFS How can i get the lun back or atleast be able to copy the vms from it

    Read the article

  • Should I make OR operator to return const reference or just reference

    - by Yan Cheng CHEOK
    class error_code { public: error_code() : hi(0), lo(0) {} error_code(__int64 lo) : hi(0), lo(lo) {} error_code(__int64 hi, __int64 lo) : hi(hi), lo(lo) {} error_code& operator|=(const error_code &e) { this->hi |= e.hi; this->lo |= e.lo; return *this; } __int64 hi; __int64 lo; }; error_code operator|(const error_code& e0, const error_code& e1) { return error_code(e0.hi | e1.hi, e0.lo | e1.lo); } int main() { error_code e0(1); error_code e1(2); e0 |= e1; } I was wondering, whether I should make operator|= to return a const error_code& or error_code& ?

    Read the article

  • How to connect SAN from CentOS through two iSCSI Targets

    - by garconcn
    I had asked the similar question before. This time I want to use subnet for two iSCSI Targets, hence I start a new question. I have an old Promise VTrak M500i SAN Server. It comes with 2 iSCSI ports. I want to connect to two LUNs on the SAN server through two separate Targets from CentOS 5.7 64bits server. My network setup is as follows: CentOS server: Management network - 192.168.1.1 Storage network 1 - 192.168.5.2 Storage network 2 - 192.168.6.2 Promise SAN server: Management network - 192.168.1.2 iSCSI Port 1 - 192.168.5.1 iSCSI Port 2 - 192.168.6.1 I have two Logical Drives on this SAN and they are mapped as follows: Index Initiator Name LUN Mapping 0 iqn.2011-11:backup (LD0,0) 1 iqn.2011-11:template (LD1,1) Basically, I want the traffic to iqn.2011-11:backup LUN 0 through 192.168.5.1 network the traffic to iqn.2011-11:template LUN 1 through 192.168.6.1 network I don't use MPIO, just want to separate the traffic to avoid traffic jam. How do I achieve this? I am new to SAN stuff, please explain as much detail as you can. Thank you. The following are what I am doing now. After mapping the LUN to my pre-defined Initiators, the CentOS server can discover both Targets. [root@centos ~]# iscsiadm -m discovery -t sendtargets -p 192.168.5.1 192.168.5.1:3260,1 iscsi-1 192.168.6.1:3260,2 iscsi-1 [root@centos ~]# iscsiadm -m discovery -t sendtargets -p 192.168.6.1 192.168.6.1:3260,2 iscsi-1 192.168.5.1:3260,1 iscsi-1 [root@centos ~]# /etc/init.d/iscsi start iscsid is stopped Starting iSCSI daemon: [ OK ] [ OK ] Setting up iSCSI targets: Logging in to [iface: default, target: iscsi-1, portal: 192.168.6.1,3260] Logging in to [iface: default, target: iscsi-1, portal: 192.168.5.1,3260] Login to [iface: default, target: iscsi-1, portal: 192.168.6.1,3260] successful. Login to [iface: default, target: iscsi-1, portal: 192.168.5.1,3260] successful. [ OK ] [root@centos ~]# iscsiadm -m session tcp: [1] 192.168.6.1:3260,2 iscsi-1 tcp: [2] 192.168.5.1:3260,1 iscsi-1 When I check the LUN mapping on the SAN server for the two Logical Drives, both LUNs are connected through Port0-192.168.5.2 with the Initiator defined in CentOS. Assigned Initiator List: Initiator Name Alias IP Address LUN iqn.2011-11.centos centos.mydomain.com Port0-192.168.5.2 0 Initiator Name Alias IP Address LUN iqn.2011-11.centos centos.mydomain.com Port1-192.168.5.2 1 I assume the following is what I want: Initiator Name Alias IP Address LUN iqn.2011-11.backup centos.mydomain.com Port0-192.168.5.2 0 Initiator Name Alias IP Address LUN iqn.2011-11.template centos.mydomain.com Port0-192.168.6.2 1

    Read the article

  • ifcf-ethx problem

    - by Shahmir Javaid
    Every time i run service networkd restart This is what i get Shutting down interface eth0: Device state: 3 (disconnected) [ OK ] Shutting down interface eth1: [ OK ] Shutting down loopback interface: Error org.freedesktop.NetworkManagerSettings.InvalidConnection: ifcfg file '/etc/sysconfig/network-scripts/ifcfg-lo' unknown Error org.freedesktop.NetworkManagerSettings.InvalidConnection: ifcfg file '/etc/sysconfig/network-scripts/ifcfg-lo' unknown Error org.freedesktop.NetworkManagerSettings.InvalidConnection: ifcfg file '/etc/sysconfig/network-scripts/ifcfg-lo' unknown Error org.freedesktop.NetworkManagerSettings.InvalidConnection: ifcfg file '/etc/sysconfig/network-scripts/ifcfg-lo' unknown [ OK ] Bringing up loopback interface: Error org.freedesktop.NetworkManagerSettings.InvalidConnection: ifcfg file '/etc/sysconfig/network-scripts/ifcfg-lo' unknown Error org.freedesktop.NetworkManagerSettings.InvalidConnection: ifcfg file '/etc/sysconfig/network-scripts/ifcfg-lo' unknown Error org.freedesktop.NetworkManagerSettings.InvalidConnection: ifcfg file '/etc/sysconfig/network-scripts/ifcfg-lo' unknown Error org.freedesktop.NetworkManagerSettings.InvalidConnection: ifcfg file '/etc/sysconfig/network-scripts/ifcfg-lo' unknown [ OK ] Bringing up interface eth0: ** (process:12951): WARNING **: fetch_connections_done: error fetching user connections: (2) The name org.freedesktop.NetworkManagerUserSettings was not provided by any .service files. Active connection state: activating Active connection path: /org/freedesktop/NetworkManager/ActiveConnection/1 state: activated Connection activated [ OK ] Here is my ifcfg-eth0 # Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller DEVICE=eth0 BOOTPROTO=dhcp DEFROUTE=yes DHCPCLASS= HWADDR=xxx IPV4_FAILURE_FATAL=yes IPV6INIT=no ONBOOT=yes OPTIONS=layer2=1 PEERDNS=yes PEERROUTES=yes TYPE=Ethernet UUID=xxx And my ifcfg-eth1 # Intel Corporation 82541PI Gigabit Ethernet Controller DEVICE=eth1 HWADDR=xxx ONBOOT=no And my ifcfg-lo DEVICE=lo IPADDR=127.0.0.1 NETMASK=255.0.0.0 NETWORK=127.0.0.0 # If you're having problems with gated making 127.0.0.0/8 a martian, # you can change this to something else (255.255.255.255, for example) BROADCAST=127.255.255.255 ONBOOT=yes NAME=loopback Any ideas?

    Read the article

  • How to migrate primary key generation from "increment" to "hi-lo"?

    - by Bevan
    I'm working with a moderate sized SQL Server 2008 database (around 120 tables, backups are around 4GB compressed) where all the table primary keys are declared as simple int columns. At present, primary key values are generated by NHibernate with the increment identity generator, which has worked well thus far, but precludes moving to a multiprocessing environment. Load on the system is growing, so I'm evaluating the work required to allow the use of multiple servers accessing a common database backend. Transitioning to the hi-lo generator seems to be the best way forward, but I can't find a lot of detail about how such a migration would work. Will NHibernate automatically create rows in the hi-lo table for me, or do I need to script these manually? If NHibernate does insert rows automatically, does it properly take account of existing key values? If NHibernate does take care of thing automatically, that's great. If not, are there any tools to help? Update NHibernate's increment identifier generator works entirely in-memory. It's seeded by selecting the maximum value of used identifiers from the table, but from that point on allocates new values by a simple increment, without reference back to the underlying database table. If any other process adds rows to the table, you end up with primary key collisions. You can run multiple threads within the one process just fine, but you can't run multiple processes. For comparison, the NHibernate identity generator works by configuring the database tables with identity columns, putting control over primary key generation in the hands of the database. This works well, but compromises the unit of work pattern. The hi-lo algorithm sits inbetween these - generation of primary keys is coordinated through the database, allowing for multiprocessing, but actual allocation can occur entirely in memory, avoiding problems with the unit of work pattern.

    Read the article

  • Can any iSCSI NAS appliance replicate / clone a LUN to an external drive?

    - by Boden
    I would like to backup using Windows Imaging to some kind of NAS appliance. I believe this will require the NAS to support iSCSI. I would then like the appliance to support the replication of the iSCSI LUN to an external eSATA or USB disk connected directly to the appliance. I've found plenty of NAS appliances that can do iSCSI and replicate to an external drive, but none that I've found thus far can do both at once. That is, the devices can do iSCSI, but then the replication feature doesn't work. The idea here is to backup to an appliance located in a secure office far away from the server room. Offsite backups to external hard drive could be managed from the appliance. The benefits of such a setup would be: 1) very unlikely that fire or random theft would affect both server-room backup and "remote" backup appliance 2) offsite backups could be managed by multiple trusted people without granting access to server room 3) Windows imaging provides poor man's deduplication, so each backup volume can contain a decent backup history. I understand why this would be a non-trivial thing to implement, but I'm wondering if such a thing exists? Preferably a tabletop, low to medium cost device. Alternative solutions welcome. NOTE: I'm backing up very few but very large files, so file replication is not a good option.

    Read the article

  • Can any iSCSI NAS appliance replicate / clone a LUN to an external drive?

    - by Boden
    I would like to backup using Windows Imaging to some kind of NAS appliance. I believe this will require the NAS to support iSCSI. I would then like the appliance to support the replication of the iSCSI LUN to an external eSATA or USB disk connected directly to the appliance. I've found plenty of NAS appliances that can do iSCSI and replicate to an external drive, but none that I've found thus far can do both at once. That is, the devices can do iSCSI, but then the replication feature doesn't work. The idea here is to backup to an appliance located in a secure office far away from the server room. Offsite backups to external hard drive could be managed from the appliance. The benefits of such a setup would be: 1) very unlikely that fire or random theft would affect both server-room backup and "remote" backup appliance 2) offsite backups could be managed by multiple trusted people without granting access to server room 3) Windows imaging provides poor man's deduplication, so each backup volume can contain a decent backup history. I understand why this would be a non-trivial thing to implement, but I'm wondering if such a thing exists? Preferably a tabletop, low to medium cost device. Alternative solutions welcome. NOTE: I'm backing up very few but very large files, so file replication is not a good option.

    Read the article

  • No rule to make target libmysql.c', needed bylibmysql.lo'. Stop

    - by user1711008
    I install mysql5.1.53, run #./configure is well, but run #make have this error. My system is centos5.8, gcc version 4.1.2 20080704 (Red Hat 4.1.2-52) make[2]: Leaving directory /root/soft/mysql-5.1.53/libmysql' make[1]: Leaving directory/root/soft/mysql-5.1.53/libmysql' Making all in libmysql_r make[1]: Entering directory /root/soft/mysql-5.1.53/libmysql_r' make all-am make[2]: Entering directory/root/soft/mysql-5.1.53/libmysql_r' make[2]: * No rule to make target libmysql.c', needed bylibmysql.lo'. Stop. make[2]: Leaving directory /root/soft/mysql-5.1.53/libmysql_r' make[1]: *** [all] Error 2 make[1]: Leaving directory/root/soft/mysql-5.1.53/libmysql_r' make: * [all-recursive] Error 1

    Read the article

  • Replication - between pools in the same system

    - by Steve Tunstall
    OK, I fully understand that's it's been a LONG time since I've blogged with any tips or tricks on the ZFSSA, and I'm way behind. Hey, I just wrote TWO BLOGS ON THE SAME DAY!!! Make sure you keep scrolling down to see the next one too, or you may have missed it. To celebrate, for the one or two of you out there who are still reading this, I got something for you. The first TWO people who make any comment below, with your real name and email so I can contact you, will get some cool Oracle SWAG that I have to give away. Don't get excited, it's not an iPad, but it pretty good stuff. Only the first two, so if you already see two below, then settle down. Now, let's talk about Replication and Migration.  I have talked before about Shadow Migration here: https://blogs.oracle.com/7000tips/entry/shadow_migrationShadow Migration lets one take a NFS or CIFS share in one pool on a system and migrate that data over to another pool in the same system. That's handy, but right now it's only for file systems like NFS and CIFS. It will not work for LUNs. LUN shadow migration is a roadmap item, however. So.... What if you have a ZFSSA cluster with multiple pools, and you have a LUN in one pool but later you decide it's best if it was in the other pool? No problem. Replication to the rescue. What's that? Replication is only for replicating data between two different systems? Who told you that? We've been able to replicate to the same system now for a few code updates back. These instructions below will also work just fine if you're setting up replication between two different systems. After replication is complete, you can easily break replication, change the new LUN into a primary LUN and then delete the source LUN. Bam. Step 1- setup a target system. In our case, the target system is ourself, but you still have to set it up like it's far away. Go to Configuration-->Services-->Remote Replication. Click the plus sign and setup the target, which is the ZFSSA you're on now. Step 2. Now you can go to the LUN you want to replicate. Take note which Pool and Project you're in. In my case, I have a LUN in Pool2 called LUNp2 that I wish to replicate to Pool1.  Step 3. In my case, I made a Project called "Luns" and it has LUNp2 inside of it. I am going to replicate the Project, which will automatically replicate all of the LUNs and/or Filesystems inside of it.  Now, you can also replicate from the Share level instead of the Project. That will only replicate the share, and not all the other shares of a project. If someone tells you that if you replicate a share, it always replicates all the other shares also in that Project, don't listen to them.Note below how I can choose not only the Target (which is myself), but I can also choose which Pool to replicate it to. So I choose Pool1.  Step 4. I did not choose a schedule or pick the "Continuous" button, which means my replication will be manual only. I can now push the Manual Replicate button on my Actions list and you will see it start. You will see both a barber pole animation and also an update in the status bar on the top of the screen that a replication event has begun. This also goes into the event log.  Step 5. The status bar will also log an event when it's done. Step 6. If you go back to Configuration-->Services-->Remote Replication, you will see your event. Step 7. Done. To see your new replica, go to the other Pool (Pool1 for me), and click the "Replica" area below the words "Filesystems | LUNs" Here, you will see any replicas that have come in from any of your sources. It's a simple matter from here to break the replication, which will change this to a "Local" LUN, and then delete the original LUN back in Pool2. Ok, that's all for now, but I promise to give out more tricks sometime in November !!! There's very exciting stuff coming down the pipe for the ZFSSA. Both new hardware and new software features that I'm just drooling over. That's all I can say, but contact your local sales SC to get a NDA roadmap talk if you want to hear more.   Happy Halloween,Steve 

    Read the article

  • overriding ctype<wchar_t>

    - by Potatoswatter
    I'm writing a lambda calculus interpreter for fun and practice. I got iostreams to properly tokenize identifiers by adding a ctype facet which defines punctuation as whitespace: struct token_ctype : ctype<char> { mask t[ table_size ]; token_ctype() : ctype<char>( t ) { for ( size_t tx = 0; tx < table_size; ++ tx ) { t[tx] = isalnum( tx )? alnum : space; } } }; (classic_table() would probably be cleaner but that doesn't work on OS X!) And then swap the facet in when I hit an identifier: locale token_loc( in.getloc(), new token_ctype ); … locale const &oldloc = in.imbue( token_loc ); in.unget() >> token; in.imbue( oldloc ); There seems to be surprisingly little lambda calculus code on the Web. Most of what I've found so far is full of unicode ? characters. So I thought to try adding Unicode support. But ctype<wchar_t> works completely differently from ctype<char>. There is no master table; there are four methods do_is x2, do_scan_is, and do_scan_not. So I did this: struct token_ctype : ctype< wchar_t > { typedef ctype<wchar_t> base; bool do_is( mask m, char_type c ) const { return base::do_is(m,c) || (m&space) && ( base::do_is(punct,c) || c == L'?' ); } const char_type* do_is (const char_type* lo, const char_type* hi, mask* vec) const { base::do_is(lo,hi,vec); for ( mask *vp = vec; lo != hi; ++ vp, ++ lo ) { if ( *vp & punct || *lo == L'?' ) *vp |= space; } return hi; } const char_type *do_scan_is (mask m, const char_type* lo, const char_type* hi) const { if ( m & space ) m |= punct; hi = do_scan_is(m,lo,hi); if ( m & space ) hi = find( lo, hi, L'?' ); return hi; } const char_type *do_scan_not (mask m, const char_type* lo, const char_type* hi) const { if ( m & space ) { m |= punct; while ( * ( lo = base::do_scan_not(m,lo,hi) ) == L'?' && lo != hi ) ++ lo; return lo; } return base::do_scan_not(m,lo,hi); } }; (Apologies for the flat formatting; the preview converted the tabs differently.) The code is WAY less elegant. I does better express the notion that only punctuation is additional whitespace, but that would've been fine in the original had I had classic_table. Is there a simpler way to do this? Do I really need all those overloads? (Testing showed do_scan_not is extraneous here, but I'm thinking more broadly.) Am I abusing facets in the first place? Is the above even correct? Would it be better style to implement less logic?

    Read the article

  • What are the common linux ( RH ) commands for SAN related activities ? How to check if a LUN is attached to the computer ?

    - by Nishant
    How do I check if a LUN has been presented to my server ? What are the Linux commands for that ? Do the LUNS show up in a fdisk -l command like a normal /dev/sda gets listed ? What are other commands assosicaed with general SAN related checks in Linux ? What is WWN and how does that have any relevance and Also please explain multipathing why if we have LUN's , what is the use of multipathing then ? Bit lenghty but I am not able to get a grasp on the topic . Any help would be appreciated .

    Read the article

  • Can I have different ESX hosts accessing the same LUN over different protocols?

    - by Kevin Kuphal
    I currently have a cluster of two ESX 3.5U2 servers connected directly via FiberChannel to a NetApp 3020 cluster. These hosts mount four VMFS LUNs for virtual machine storage. Currently these LUNs are only made available via our FiberChannel initator in the Netapp configuration If I were to add an ESXi host to the cluster for internal IT use can I: Make the same VMFS LUNs available via the iSCSI initiator on the Netapp Connect this ESXi host to those LUNs via iSCSI Do all of this while the existing two ESX hosts are connected to those LUNs via FiberChannel Does anyone have experience with this type of mixed protocol environment, specifically with Netapp?

    Read the article

  • I flashed my DS4700 with a 7 series firmware, now my DS4300 cannot read the disks I moved to that lo

    - by Daniel Hoeving
    In preparation for adding a number of 1Tb SATA disks to our DS4700 I flashed the controller firmware from a 6 series (which only supports up to 2Tb logical drives) to a 7 series (which supports larger than 2Tb logical drives). Attached to this DS4700 was a EXP710 expansion drawer that we had planned to migrate out to our co-location to allieviate the storage issues we were having there. Unfortunately these two projects were planned in isolation to one another so I was at the time unaware of the issue that this would cause. Prior to migrating the drawer I was reading the "IBM TotalStorage DS4000 EXP700 and EXP710 Storage Expansion EnclosuresInstallation, User’s, and Maintenance Guide" and discovered this: Controller firmware 6.xx or earlier has a different metadata (DACstore) data structure than controller firmware 7.xx.xx.xx. Metadata consists of the array and logical drive configuration data. These two metadata data structures are not interchangeable. When powered up and in Optimal state, the storage subsystem with controller firmware level 7.xx.xx.xx can convert the metadata from the drives configured in storage subsystems with controller firmware level 6.xx or earlier to controller firmware level 7.xx.xx.xx metadata data structure. However, the storage subsystem with controller firmware level 6.xx or earlier cannot read the metadata from the drives configured in storage subsystems with controller firmware level 7.xx.xx.xx or later. I had assumed that if I deleted the logical drives and array information on the EXP710 prior to migrating it to the DS4300 (6.60.22 firmware) this would satisfy the above, unfortunately I was wrong. So my question is a) Is it possible to restore the DAC information to its factory settings, b) What tool(s) would I use to accomplish this, or c) is this a lost cause? Daniel.

    Read the article

  • What privilege level is required on a Windows client workstation on an ActiveDomain to break file lo

    - by Mike Burton
    I'm not sure if I should be asking this here or on StackOverflow, but here goes: I'm part of a team maintaining a document management application, and I'm trying to figure out Windows file locking permissions. We use a utility somebody downloaded years ago called psunlock to remotely close all locks on a file. We recently discovered that this does not work across different domains on our VPN. A little bit of digging lead me to the samba manual's discussion of file locking. I still don't really "get it", though. Does anyone have any insight to share into how the process of locking and breaking locks on files works in a network context? My thinking is that privileges are required both on the file appliance and on the client workstations which hold locks. Is that accurate? Can anyone give a more specific version? Ideally I'm looking for something along the lines of A user must have privilege level X in order to break locks held from a client workstation. In practice I'd be happy with a hotlink to a good white paper on the subject.

    Read the article

  • Create XFS volume on /dev/sg* device

    - by cpt.Buggy
    Now I have couple of Supermicro 24x2Tb SATA servers and I have now idea how to get access to disks. I need to create XFS volume on each of them but really don't know how to do it, because fdisk doesn't see them. # sg_scan -i /dev/sg0: scsi0 channel=0 id=0 lun=0 [em] ATA ST3250318AS CC38 [rmb=0 cmdq=0 pqual=0 pdev=0x0] /dev/sg1: scsi1 channel=0 id=0 lun=0 [em] ATA ST3250318AS CC38 [rmb=0 cmdq=0 pqual=0 pdev=0x0] /dev/sg2: scsi6 channel=1 id=8 lun=0 [em] Hitachi HDS722020ALA330 JKAO [rmb=0 cmdq=1 pqual=1 pdev=0x0] ... ... ... /dev/sg25: scsi6 channel=1 id=31 lun=0 [em] Hitachi HDS722020ALA330 JKAO [rmb=0 cmdq=1 pqual=1 pdev=0x0] /dev/sg26: scsi6 channel=3 id=0 lun=0 [em] LSILOGIC SASX36 A.1 7017 [rmb=0 cmdq=1 pqual=0 pdev=0xd] # sg_map /dev/sg0 /dev/sda /dev/sg1 /dev/sdb /dev/sg2 .. ... ... /dev/sg25 /dev/sg26 I can't use fdisk and mkfs, what should I do?

    Read the article

  • Is it possible to limit output bandwidth between eth0 and lo?

    - by mmcbro
    I'm trying to limit the bandwidth between my eth0 output (nginx proxy) to my loopback inteface (apache) by filtering on destination port. Incoming Packet -> Eth0 -> 0.0.0.0:80 Nginx -> tc qdisc class/iptable mangle 2525port -> 127.0.0.1:2525 Apache I don't know if it's even possible I'm just experimenting. My rules are the followings : tc qdisc add dev eth0 root handle 1:0 htb tc class add dev eth0 parent 1:0 classid 1:10 htb rate 2mbps ceil 2mbps prio 0 tc filter add dev eth0 parent 1:0 prio 0 protocol ip handle 10 fw flowid 1:10 iptables -A OUTPUT -t mangle -p tcp --dport 2525 -j MARK --set-mark 10 I also tried to with FORWARD chain but its still the same.

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >