Search Results

Search found 427 results on 18 pages for 'sc'.

Page 2/18 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Why does a pdf file download result in varying bytes logged, all with sc-status 200

    - by Pat James
    I have a mojoportal CMS installation on an IIS7 server where users are reporting problems downloading a pdf file. It always downloads fine for me and most others, either displaying in browser or in Adobe Reader. Using logparser to query the IIS logs, all the responses are status 200 (OK) or 304 (Not modified), but the bytes sent vary quite a bit. Sometimes zero, some 211, some about half the full file size of 27059, and lots in between. Plenty show the full size of 27059. Do these other entries for smaller byte counts represent errors of some kind, correlating with the problems reported? Is this likely to be a browser/client issue or a server side problem? If there is any other info that would be helpful let me know. This is a shared hosting server though so I am somewhat limited in what I can dig into on the server.

    Read the article

  • How can I get the path to a Windows service executable WITHOUT using sc qc?

    - by Jared
    I need to query a windows service for the path to it's executable via the command prompt. I think the way I would do this is:sc qc myServiceName, but when I do that, I get the following error: [SC] QueryServiceConfig FAILED 122: The data area passed to a system call is too small. [SC] GetServiceConfig needs 1094 bytes I think this means that the sc command is sending a data structure to some other library that is too small for the data that needs to be returned. Instead of SC nicely retrying with a larger data structure (1094 bytes) it bombs out and gives me this ugly error message. Thanks Micro$oft. So is there a way to work around this error? I just need the path to the executable, but will parse it out of some other text if needed.

    Read the article

  • Reasoner Conversion Problems:

    - by Annalyne
    I have this code right here in Java and I wanted to translate it in C++, but I had some problems going: this is the java code: import java.io.*; import java.util.*; public class ClueReasoner { private int numPlayers; private int playerNum; private int numCards; private SATSolver solver; private String caseFile = "cf"; private String[] players = {"sc", "mu", "wh", "gr", "pe", "pl"}; private String[] suspects = {"mu", "pl", "gr", "pe", "sc", "wh"}; private String[] weapons = {"kn", "ca", "re", "ro", "pi", "wr"}; private String[] rooms = {"ha", "lo", "di", "ki", "ba", "co", "bi", "li", "st"}; private String[] cards; public ClueReasoner() { numPlayers = players.length; // Initialize card info cards = new String[suspects.length + weapons.length + rooms.length]; int i = 0; for (String card : suspects) cards[i++] = card; for (String card : weapons) cards[i++] = card; for (String card : rooms) cards[i++] = card; numCards = i; // Initialize solver solver = new SATSolver(); addInitialClauses(); } private int getPlayerNum(String player) { if (player.equals(caseFile)) return numPlayers; for (int i = 0; i < numPlayers; i++) if (player.equals(players[i])) return i; System.out.println("Illegal player: " + player); return -1; } private int getCardNum(String card) { for (int i = 0; i < numCards; i++) if (card.equals(cards[i])) return i; System.out.println("Illegal card: " + card); return -1; } private int getPairNum(String player, String card) { return getPairNum(getPlayerNum(player), getCardNum(card)); } private int getPairNum(int playerNum, int cardNum) { return playerNum * numCards + cardNum + 1; } public void addInitialClauses() { // TO BE IMPLEMENTED AS AN EXERCISE // Each card is in at least one place (including case file). for (int c = 0; c < numCards; c++) { int[] clause = new int[numPlayers + 1]; for (int p = 0; p <= numPlayers; p++) clause[p] = getPairNum(p, c); solver.addClause(clause); } // If a card is one place, it cannot be in another place. // At least one card of each category is in the case file. // No two cards in each category can both be in the case file. } public void hand(String player, String[] cards) { playerNum = getPlayerNum(player); // TO BE IMPLEMENTED AS AN EXERCISE } public void suggest(String suggester, String card1, String card2, String card3, String refuter, String cardShown) { // TO BE IMPLEMENTED AS AN EXERCISE } public void accuse(String accuser, String card1, String card2, String card3, boolean isCorrect) { // TO BE IMPLEMENTED AS AN EXERCISE } public int query(String player, String card) { return solver.testLiteral(getPairNum(player, card)); } public String queryString(int returnCode) { if (returnCode == SATSolver.TRUE) return "Y"; else if (returnCode == SATSolver.FALSE) return "n"; else return "-"; } public void printNotepad() { PrintStream out = System.out; for (String player : players) out.print("\t" + player); out.println("\t" + caseFile); for (String card : cards) { out.print(card + "\t"); for (String player : players) out.print(queryString(query(player, card)) + "\t"); out.println(queryString(query(caseFile, card))); } } public static void main(String[] args) { ClueReasoner cr = new ClueReasoner(); String[] myCards = {"wh", "li", "st"}; cr.hand("sc", myCards); cr.suggest("sc", "sc", "ro", "lo", "mu", "sc"); cr.suggest("mu", "pe", "pi", "di", "pe", null); cr.suggest("wh", "mu", "re", "ba", "pe", null); cr.suggest("gr", "wh", "kn", "ba", "pl", null); cr.suggest("pe", "gr", "ca", "di", "wh", null); cr.suggest("pl", "wh", "wr", "st", "sc", "wh"); cr.suggest("sc", "pl", "ro", "co", "mu", "pl"); cr.suggest("mu", "pe", "ro", "ba", "wh", null); cr.suggest("wh", "mu", "ca", "st", "gr", null); cr.suggest("gr", "pe", "kn", "di", "pe", null); cr.suggest("pe", "mu", "pi", "di", "pl", null); cr.suggest("pl", "gr", "kn", "co", "wh", null); cr.suggest("sc", "pe", "kn", "lo", "mu", "lo"); cr.suggest("mu", "pe", "kn", "di", "wh", null); cr.suggest("wh", "pe", "wr", "ha", "gr", null); cr.suggest("gr", "wh", "pi", "co", "pl", null); cr.suggest("pe", "sc", "pi", "ha", "mu", null); cr.suggest("pl", "pe", "pi", "ba", null, null); cr.suggest("sc", "wh", "pi", "ha", "pe", "ha"); cr.suggest("wh", "pe", "pi", "ha", "pe", null); cr.suggest("pe", "pe", "pi", "ha", null, null); cr.suggest("sc", "gr", "pi", "st", "wh", "gr"); cr.suggest("mu", "pe", "pi", "ba", "pl", null); cr.suggest("wh", "pe", "pi", "st", "sc", "st"); cr.suggest("gr", "wh", "pi", "st", "sc", "wh"); cr.suggest("pe", "wh", "pi", "st", "sc", "wh"); cr.suggest("pl", "pe", "pi", "ki", "gr", null); cr.printNotepad(); cr.accuse("sc", "pe", "pi", "bi", true); } } how can I convert this? there are too many errors I get. for my C++ code (as a commentor asked for) #include <iostream> #include <cstdlib> #include <string> using namespace std; void Scene_Reasoner() { int numPlayer; int playerNum; int cardNum; string filecase = "Case: "; string players [] = {"sc", "mu", "wh", "gr", "pe", "pl"}; string suspects [] = {"mu", "pl", "gr", "pe", "sc", "wh"}; string weapons [] = {"kn", "ca", "re", "ro", "pi", "wr"}; string rooms[] = {"ha", "lo", "di", "ki", "ba", "co", "bi", "li", "st"}; string cards [0]; }; void Scene_Reason_Base () { numPlayer = players.length; // Initialize card info cards = new String[suspects.length + weapons.length + rooms.length]; int i = 0; for (String card : suspects) cards[i++] = card; for (String card : weapons) cards[i++] = card; for (String card : rooms) cards[i++] = card; cardNum = i; }; private int getCardNum (string card) { for (int i = 0; i < numCards; i++) if (card.equals(cards[i])) return i; cout << "Illegal card: " + card <<endl; return -1; }; private int getPairNum(String player, String card) { return getPairNum(getPlayerNum(player), getCardNum(card)); }; private int getPairNum(int playerNum, int cardNum) { return playerNum * numCards + cardNum + 1; }; int main () { return 0; }

    Read the article

  • Java - Google App Engine - InvalidClassException when I change a class that was stored in session sc

    - by Spines
    I updated my User class, and now whenever someone that had the old version of the User class stored in their session scope accesses my site, I get an InvalidClassException. javax.servlet.ServletException: java.lang.RuntimeException: java.io.InvalidClassException: User; local class incompatible: stream classdesc serialVersionUID = 4949038118012519093, local class serialVersionUID = -971500502189813151 How do I stop this error from happening for those users? I could probably invalidate everyone's sessions every time I want to update a class that gets stored in session scope, but is there a better way, so that my user's don't have to login again?

    Read the article

  • Executing sc.exe from .NET Process unable to start and stop service.

    - by Jason
    I'm trying to restart the service from a remote machine. Here is my code. The problem is that I need to enter startinfo.filename = "sc.exe" since I'm putting "start /wait sc" this is causing an error. Here is my code, any thoughts. Also if anyone has any idea how to keep the cmd window open after this is ran so I could see the code that was ran that would be awesome. string strCommandStop1; string strCommandStop2; string strCommandStart1; string strCommandStart2; string strServer = "\\" + txtServerName.Text; string strDb1 = "SqlAgent$" + txtInsName.Text; string strDb2 = "MSSQL$" + txtInsName.Text; strCommandStop1 = @"start /wait sc " + strServer + " Stop " + strDb1; strCommandStop2 = @"start /wait sc " + strServer + " Stop " + strDb2; strCommandStart1 = @"start /wait sc " + strServer + " Start " + strDb2; strCommandStart2 = @"start /wait sc " + strServer + " Start " + strDb1; try { ProcessStartInfo startInfo = new ProcessStartInfo(); startInfo.CreateNoWindow = true; startInfo.Arguments = strCommandStop1; startInfo.Arguments = strCommandStop2; startInfo.Arguments = strCommandStart1; startInfo.Arguments = strCommandStart2; startInfo .FileName = "sc.exe"; Process.Start(startInfo); } catch (Exception e) { MessageBox.Show(e.Message); }

    Read the article

  • Problem in to navigate on UITableView on the UIButtonClick which is present in UITabBarController sc

    - by Rajendra Bhole
    Hi, I develop an application in which i want to on UIButton Click the application navigate on UITableViewcontroller class.The UIButton is already on UITabBarController during the navigation the tab bar should be visible.The calling method in first tab bar controller class is, [appDelegate.nvcHome pushViewController:itemMenuTable animated:YES]; [itemMenuTable release]; itemMenuTable = nil; But it given me the following problem in GDB, Application tried to push a nil view controller on target . Also i want to display the icon and title of UITabBarController in programmatically, the code is, homeViewControllerLink = [[homeViewController alloc]initWithNibName:@"homeViewController" bundle:nil]; nvcHome = [[UINavigationController alloc]initWithRootViewController:homeViewControllerLink]; nvcHome.navigationBar.barStyle = UIStatusBarStyleBlackOpaque; UIImage *imgHomeTab = [UIImage imageNamed:@"home"]; [nvcHome.tabBarItem initWithTitle:@"Home" image:imgHomeTab tag:101]; [homeViewControllerLink release]; But it does not display when i running my app on iphone simulator.

    Read the article

  • a minimal change to my code is breaking it

    - by Delirium tremens
    Works (it sets lasturi): var domainnameuri; var generaldomainnameuri; domainnameuri = sc.domainnameuri; generaldomainnameuri = sc.generaldomainnameuri; sc.redirectinggeneral = false; $.ajax({ type: "GET", url: generaldomainnameuri, success: function(data, textStatus) { if (data.redirect == domainnameuri) { sc.redirectinggeneral = true; } sc.setlasturi(); } }); Doesn't work (it doesn't set lasturi): this.setredirectinggeneral = function(c) { var domainnameuri; var generaldomainnameuri; domainnameuri = sc.domainnameuri; generaldomainnameuri = sc.generaldomainnameuri; sc.redirectinggeneral = false; $.ajax({ type: "GET", url: generaldomainnameuri, success: function(data, textStatus) { if (data.redirect == domainnameuri) { sc.redirectinggeneral = true; } c(); } }); } sc.setredirectinggeneral(sc.setlasturi); Why?

    Read the article

  • Saving more corsor positions (with tput?) in bash terminal

    - by AndreasT
    I know that tput sc saves the current cursor position and tput rc restores it exactly where tput sc was called. The problem is that every time tput sc is called, it overwrites the previous saved position. Is there a way to save more positions, e.g. tput sc pos1 and tput sc pos2 which can be restored with, say, tput rc pos1 and tput rc pos2 respectively? (The solution need not make use of tput, I mentioned it because it's the only command I know that handles cursor position) If not, is there a way to at least save the cursor position locally in a function, so that if a function uses tput sc and then calls another function that runs again tput sc, then each function restores its own saved cursor position when invoking tput rc? Thanks in advance.

    Read the article

  • check two conditions in two different columns in excel and count the matches

    - by user1727103
    I've trying to create a Error Log to help me analyse my mistakes. So for simplicity, lets assume I have two columns "Type of Question" - with values SC,RC,CR and another column that indicates whether I got this question "right/wrong".Let's assume this is my table: Question No. | Right/Wrong | Question Type | Right | SC | Right | RC | Wrong | SC | Wrong | CR | Right | RC (Pardon my formatting skills). And I want an output table like this Type of Question | Right | Wrong | Total SC | 1 | 1 | 2 RC | 2 | 0 | 2 CR | 0 | 1 | 1 So basically what I want to do is check Column3 for SC using =COUNTIF(C1:C5,"SC"), and return the total number of SC questions, and then outta the SC , I need to find out which are Right.If I know the right and the total I can get the wrong. I have never written a macro so a formula based answer would suffice.

    Read the article

  • non blocking client server chat application in java using nio

    - by Amith
    I built a simple chat application using nio channels. I am very much new to networking as well as threads. This application is for communicating with server (Server / Client chat application). My problem is that multiple clients are not supported by the server. How do I solve this problem? What's the bug in my code? public class Clientcore extends Thread { SelectionKey selkey=null; Selector sckt_manager=null; public void coreClient() { System.out.println("please enter the text"); BufferedReader stdin=new BufferedReader(new InputStreamReader(System.in)); SocketChannel sc = null; try { sc = SocketChannel.open(); sc.configureBlocking(false); sc.connect(new InetSocketAddress(8888)); int i=0; while (!sc.finishConnect()) { } for(int ii=0;ii>-22;ii++) { System.out.println("Enter the text"); String HELLO_REQUEST =stdin.readLine().toString(); if(HELLO_REQUEST.equalsIgnoreCase("end")) { break; } System.out.println("Sending a request to HelloServer"); ByteBuffer buffer = ByteBuffer.wrap(HELLO_REQUEST.getBytes()); sc.write(buffer); } } catch (IOException e) { e.printStackTrace(); } finally { if (sc != null) { try { sc.close(); } catch (Exception e) { e.printStackTrace(); } } } } public void run() { try { coreClient(); } catch(Exception ej) { ej.printStackTrace(); }}} public class ServerCore extends Thread { SelectionKey selkey=null; Selector sckt_manager=null; public void run() { try { coreServer(); } catch(Exception ej) { ej.printStackTrace(); } } private void coreServer() { try { ServerSocketChannel ssc = ServerSocketChannel.open(); try { ssc.socket().bind(new InetSocketAddress(8888)); while (true) { sckt_manager=SelectorProvider.provider().openSelector(); ssc.configureBlocking(false); SocketChannel sc = ssc.accept(); register_server(ssc,SelectionKey.OP_ACCEPT); if (sc == null) { } else { System.out.println("Received an incoming connection from " + sc.socket().getRemoteSocketAddress()); printRequest(sc); System.err.println("testing 1"); String HELLO_REPLY = "Sample Display"; ByteBuffer buffer = ByteBuffer.wrap(HELLO_REPLY.getBytes()); System.err.println("testing 2"); sc.write(buffer); System.err.println("testing 3"); sc.close(); }}} catch (IOException e) { e.printStackTrace(); } finally { if (ssc != null) { try { ssc.close(); } catch (IOException e) { e.printStackTrace(); } } } } catch(Exception E) { System.out.println("Ex in servCORE "+E); } } private static void printRequest(SocketChannel sc) throws IOException { ReadableByteChannel rbc = Channels.newChannel(sc.socket().getInputStream()); WritableByteChannel wbc = Channels.newChannel(System.out); ByteBuffer b = ByteBuffer.allocate(1024); // read 1024 bytes while (rbc.read(b) != -1) { b.flip(); while (b.hasRemaining()) { wbc.write(b); System.out.println(); } b.clear(); } } public void register_server(ServerSocketChannel ssc,int selectionkey_ops)throws Exception { ssc.register(sckt_manager,selectionkey_ops); }} public class HelloClient { public void coreClientChat() { Clientcore t=new Clientcore(); new Thread(t).start(); } public static void main(String[] args)throws Exception { HelloClient cl= new HelloClient(); cl.coreClientChat(); }} public class HelloServer { public void coreServerChat() { ServerCore t=new ServerCore(); new Thread(t).start(); } public static void main(String[] args) { HelloServer st= new HelloServer(); st.coreServerChat(); }}

    Read the article

  • Sending Email through Gmail

    - by persistence
    I am writing a program that send an email through GMail but I have serious Operation timeout error. What is the likely cause. class Mailer { MailMessage ms; SmtpClient Sc; public Mailer() { Sc = new SmtpClient("smtp.gmail.com"); //Sc.Credentials = CredentialCache.DefaultNetworkCredentials; Sc.EnableSsl = true; Sc.Port =465; Sc.Timeout = 900000000; Sc.DeliveryMethod = SmtpDeliveryMethod.Network; Sc.UseDefaultCredentials = false; Sc.Credentials = new NetworkCredential("uid", "mypss"); } public void MailTodaysBirthdays(List<Celebrant> TodaysCelebrant) { int i = TodaysCelebrant.Count(); foreach (Celebrant cs in TodaysCelebrant) { //if (IsEmail(cs.EmailAddress.ToString().Trim())) //{ ms = new MailMessage(); ms.To.Add(cs.EmailAddress); ms.From = new MailAddress("uid","Developers",System.Text.Encoding.UTF8); ms.Subject = "Happy Birthday "; String EmailBody = "Happy Birthday " + cs.FirstName; ms.Body = EmailBody; ms.Priority = MailPriority.High; try { Sc.Send(ms); } catch (Exception ex) { Sc.Send(ms); BirthdayServices.LogEvent(ex.Message.ToString(),EventLogEntryType.Error); } //} } } }

    Read the article

  • SQL SERVER – Find Details for Statistics of Whole Database – DMV – T-SQL Script

    - by pinaldave
    I was recently asked is there a single script which can provide all the necessary details about statistics for any database. This question made me write following script. I was initially planning to use sp_helpstats command but I remembered that this is marked to be deprecated in future. Again, using DMV is the right thing to do moving forward. I quickly wrote following script which gives a lot more information than sp_helpstats. USE AdventureWorks GO SELECT DISTINCT OBJECT_NAME(s.[object_id]) AS TableName, c.name AS ColumnName, s.name AS StatName, s.auto_created, s.user_created, s.no_recompute, s.[object_id], s.stats_id, sc.stats_column_id, sc.column_id, STATS_DATE(s.[object_id], s.stats_id) AS LastUpdated FROM sys.stats s JOIN sys.stats_columns sc ON sc.[object_id] = s.[object_id] AND sc.stats_id = s.stats_id JOIN sys.columns c ON c.[object_id] = sc.[object_id] AND c.column_id = sc.column_id JOIN sys.partitions par ON par.[object_id] = s.[object_id] JOIN sys.objects obj ON par.[object_id] = obj.[object_id] WHERE OBJECTPROPERTY(s.OBJECT_ID,'IsUserTable') = 1 AND (s.auto_created = 1 OR s.user_created = 1); If you have better script to retrieve information about statistics, please share here and I will publish it with due credit. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL DMV, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, T SQL, Technology Tagged: SQL Statistics, Statistics

    Read the article

  • Cannot delete an existing service using sc command: The Specified service does not exist as an installed service

    - by Graviton
    As shown in the picture below, I want to delete MyNewService, but when I type in sc delete MyNewService I simply can't delete it because there is no such servic, due to "the Specified service does not exist as an installed service" error Any ideas how to solve this problem? Edit: as far as the service panel is concerned, the MyNewService is there all the time; I restarted the pc a few times, and it's there.

    Read the article

  • what virtual machine should dell poweredg sc 1425 install?

    - by Nguyen Khanh Huy
    I'm intalling our local server and want to install a virtual machine but it seem vmware ESXi is not suit with our server Server: Dell SC 1424 CPU : 2 Xeon 3.2G (buss 800, cache L2 2M) Ram: 6G DDR ECC 266 Hard disk: 2 Hitachi Sata 1TB. Raid Dell Cerc 2s ( raid 0, 1) Nic: 2 Broadcom 1Gb/s I'm wondering if you're familiar with this area and have any idea about a VM software for our server. Just wanted to use server for some purposes ( web hosting, subversion and to experience some server OSs) Thank you for helping.

    Read the article

  • Altering a Column Which has a Default Constraint

    - by Dinesh Asanka
    Setting up a default column is a common task for  developers.  But, are we naming those default constraints explicitly? In the below  table creation, for the column, sys_DateTime the default value Getdate() will be allocated. CREATE TABLE SampleTable (ID int identity(1,1), Sys_DateTime Datetime DEFAULT getdate() ) We can check the relevant information from the system catalogs from following query. SELECT sc.name TableName, dc.name DefaultName, dc.definition, OBJECT_NAME(dc.parent_object_id) TableName, dc.is_system_named  FROM sys.default_constraints dc INNER JOIN sys.columns sc ON dc.parent_object_id = sc.object_id AND dc.parent_column_id = sc.column_id and results would be: Most of the above columns are self-explanatory. The last column, is_system_named, is to identify whether the default name was given by the system. As you know, in the above case, since we didn’t provide  any default name, the  system will generate a default name for you. But the problem with these names is that they can differ from environment to environment.  If example if I create this table in different table the default name could be DF__SampleTab__Sys_D__7E6CC920 Now let us create another default and explicitly name it: CREATE TABLE SampleTable2 (ID int identity(1,1), Sys_DateTime Datetime )   ALTER TABLE SampleTable2 ADD CONSTRAINT DF_sys_DateTime_Getdate DEFAULT( Getdate()) FOR Sys_DateTime If we run the previous query again we will be returned the below output. And you can see that last created default name has 0 for is_system_named. Now let us say I want to change the data type of the sys_DateTime column to something else: ALTER TABLE SampleTable2 ALTER COLUMN Sys_DateTime Date This will generate the below error: Msg 5074, Level 16, State 1, Line 1 The object ‘DF_sys_DateTime_Getdate’ is dependent on column ‘Sys_DateTime’. Msg 4922, Level 16, State 9, Line 1 ALTER TABLE ALTER COLUMN Sys_DateTime failed because one or more objects access this column. This means, you need to drop the default constraint before altering it: ALTER TABLE [dbo].[SampleTable2] DROP CONSTRAINT [DF_sys_DateTime_Getdate] ALTER TABLE SampleTable2 ALTER COLUMN Sys_DateTime Date   ALTER TABLE [dbo].[SampleTable2] ADD CONSTRAINT [DF_sys_DateTime_Getdate] DEFAULT (getdate()) FOR [Sys_DateTime] If you have a system named default constraint that can differ from environment to environment and so you cannot drop it as before, you can use the below code template: DECLARE @defaultname VARCHAR(255) DECLARE @executesql VARCHAR(1000)   SELECT @defaultname = dc.name FROM sys.default_constraints dc INNER JOIN sys.columns sc ON dc.parent_object_id = sc.object_id AND dc.parent_column_id = sc.column_id WHERE OBJECT_NAME (parent_object_id) = 'SampleTable' AND sc.name ='Sys_DateTime' SET @executesql = 'ALTER TABLE SampleTable DROP CONSTRAINT ' + @defaultname EXEC( @executesql) ALTER TABLE SampleTable ALTER COLUMN Sys_DateTime Date ALTER TABLE [dbo].[SampleTable] ADD DEFAULT (Getdate()) FOR [Sys_DateTime]

    Read the article

  • installing windows service with SC.exe or InstallUtil.exe - there is difference but which?

    - by LosManos
    hejdig. SC.exe and InstallUtil both install/uninstall windows services. But they don't seem to work the same way. What is the difference? For instance InstallUtil fails (some file or dependency not found error) while Sc create happily installs the service. Too add to the strangeness; the service doesn't show up if I run net start in the console. But it does show up in the services GUI. Variants of this happen when I try to uninstall. I have written the service myself and earlier versions work. Dotnet3.5. /OF

    Read the article

  • Best practice for creating objects used in for/foreach loops

    - by StupidDeveloper
    Hi! What's the best practice for dealing with objects in for or foreach loops? Should we create one object outside the loops and recreate it all over again (using new... ) or create new one for every loop iteration? Example: foreach(var a in collection) { SomeClass sc = new SomeClass(); sc.id = a; sc.Insert(); } or SomeClass sc = null; foreach(var a in collection) { sc = new SomeClass(); sc.id = a; sc.Insert(); } Which is better?

    Read the article

  • Open source clone for Starcraft

    - by sinekonata
    Two questions about a SC:Broodwar clone. Is there one yet? How likely is legal pursuit? Since almost all games I usually play now have an FOS alternative from alpha to way polished, I was wondering why can't I find one for SC, one of the biggest titans of the gaming community? So my first question is, is there a game that was made with the intention to emulate SC? Is it that I didn't look well enough? Could it really be that no one tackled what seems like a small effort compared to the creation of a game engine like Spring or games like Rigs of Rod or Minetest? And since SC is not being maintained at all shouldn't the incentive to see a bug free modable balanced version huge? What am I not getting here? In the event that there is none, is it a legal problem? Could it be that people expect Blizzard to release sources themselves? Or that developers don't see the point in having SC mechanics without the patented lore and aesthetics? And the trickier question, if I were to make SC an open source game, a total clone of it for the purposes of maintenance, modability, etc. Would Blizzard really sue a team of developer fans that just do them a favour knowing they don't lose any money from Korea broadcasts? Or would they do it not to set precedents. So thanks for reading all that, hope I'm not the only one to think it's weird that no one talks about it. See you.

    Read the article

  • Win Server 2008: Task Scheduler runs programs twice or late

    - by SomeName
    Hi, I need to restart a service every day. I have logon hours restricted at 3:00 am, and the server will logout existing TS connections. I have two tasks scheduled: "Daily At 3:20 am every day" "start a program" "c:\windows\system32\sc.exe stop myservice" "Daily At 3:22 am every day" "start a program" "c:\windows\system32\sc.exe start myservice" I came in today to notice that the service wasn't running. I've been digging in logs, and found these entries: For stop task, history: a) 3:29:35 am: Action Completed (sc result code 0) b) 3:20:00 am: Action Completed (sc result code 0) For start task, history: a) 3:29:35 am: Action Completed (sc result code ERROR_SERVICE_ALREADY_RUNNING 1056 (0x420)) b) 3:22:01 am: Action Completed (sc result code 0) Checking event logs shows me: a) 3:29:35 am, Application log, Source myservice, "The service was stopped" b) 3:29:25 am, System log, Source Service Control Manager, "The myservice service entered the stopped state" So, What would have caused both tasks to run at 3:29 am? Why don't I see a message from the SCM saying that the service entered the running state? Is this the preferred way to do this? Thanks!

    Read the article

  • Java Error When correct code is put together

    - by Eric
    I have a few string problems that I need to put together for a complete homework assignment. They all work correctly by themselves, but when I put them together in the main function, the last one that finds the smallest word in a string gives an error. Anyone know why? public static void main(String[] args){ Scanner sc = new Scanner(System.in); //Length of Word String word1 = sc.next(); System.out.println(word1.length()); //Evens in one string odds in the other String word2 = sc.next(); StringBuilder even = new StringBuilder(); StringBuilder odd = new StringBuilder(); for(int i = 0; i < word2.length(); i++){ if(i % 2 == 0){ even.append(word2.charAt(i)); } else{ odd.append(word2.charAt(i)); } } System.out.println(even + " " + odd); //Diminishing Suffix String word3 = sc.next(); for(int j = 0; j < word3.length(); j++){ System.out.print(word3.substring(j, word3.length()) + " "); } System.out.printf("\n"); //Letter Replacement String word4 = sc.next(); String word5 = sc.next(); String word6 = sc.next(); String word7 = word4.replace(word5, word6); System.out.println(word7); //How many times x appears in xstring String word8 = sc.next(); String word9 = sc.next(); int index = word8.indexOf(word9); int count = 0; while (index != -1) { count++; word8 = word8.substring(index + 1); index = word8.indexOf(word9); } System.out.println(count); System.out.println(); //Lexicographically smallest word String Sentence = sc.nextLine(); String[] myWords = Sentence.split(" "); int shortestLengths, shortestLocation; shortestLengths=(myWords[1]).length(); shortestLocation=1; for (int i = 1; i <myWords.length; i++) { if ((myWords[i]).length() < shortestLengths) { shortestLengths=(myWords[i]).length(); shortestLocation=i; } } System.out.println(myWords[shortestLocation]); } } Talking about the lexicographically smallest one

    Read the article

  • SATA errors reported during boot: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0

    - by digby280
    I have noticed some error during the Linux boot. They seem to continue to occur after the boot adding lines to the log every few seconds. Once booted this normally does not appear to be causing any problems. However, around 1 in 10 boots results in a kernel panic and the computer has on two or three occasions suddenly rebooted after being powered on for a number of hours. I presume the cause of the reboot is a kernel panic as well. I am running Ubuntu 11.10 and I have had Ubuntu installed on the computer for around a year. I have googled around and not found anything useful. I have provided the kernel log lines and the output of smartctl. Can anyone explain exactly what these errors mean, or better still how to resolve them? Apr 2 16:51:27 dell580 kernel: [ 19.831140] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:27 dell580 kernel: [ 19.934194] tg3 0000:03:00.0: eth0: Link is down Apr 2 16:51:28 dell580 kernel: [ 20.929468] tg3 0000:03:00.0: eth0: Link is up at 100 Mbps, full duplex Apr 2 16:51:28 dell580 kernel: [ 20.929471] tg3 0000:03:00.0: eth0: Flow control is on for TX and on for RX Apr 2 16:51:28 dell580 kernel: [ 20.929727] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready Apr 2 16:51:29 dell580 kernel: [ 21.609381] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:29 dell580 kernel: [ 21.616515] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:29 dell580 kernel: [ 21.616519] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:29 dell580 kernel: [ 21.616525] ata2.00: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 21.934036] ata2.01: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 22.408890] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.408907] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.440934] ata2.00: configured for UDMA/100 Apr 2 16:51:29 dell580 kernel: [ 22.449040] ata2.01: configured for UDMA/133 Apr 2 16:51:29 dell580 kernel: [ 22.449818] ata2: EH complete Apr 2 16:51:33 dell580 kernel: [ 26.122664] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:33 dell580 kernel: [ 26.122670] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:33 dell580 kernel: [ 26.122677] ata2.00: hard resetting link Apr 2 16:51:33 dell580 kernel: [ 26.442684] ata2.01: hard resetting link Apr 2 16:51:34 dell580 kernel: [ 26.925545] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.925561] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.961542] ata2.00: configured for UDMA/100 Apr 2 16:51:34 dell580 kernel: [ 26.969616] ata2.01: configured for UDMA/133 Apr 2 16:51:34 dell580 kernel: [ 26.970400] ata2: EH complete Apr 2 16:51:35 dell580 kernel: [ 28.111180] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:35 dell580 kernel: [ 28.111184] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:35 dell580 kernel: [ 28.111191] ata2.00: hard resetting link Apr 2 16:51:35 dell580 kernel: [ 28.429674] ata2.01: hard resetting link Apr 2 16:51:36 dell580 kernel: [ 28.904557] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.904572] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.936609] ata2.00: configured for UDMA/100 Apr 2 16:51:36 dell580 kernel: [ 28.944692] ata2.01: configured for UDMA/133 Apr 2 16:51:36 dell580 kernel: [ 28.945464] ata2: EH complete Apr 2 16:51:38 dell580 kernel: [ 31.581756] eth0: no IPv6 routers present Apr 2 16:51:38 dell580 kernel: [ 32.103066] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:38 dell580 kernel: [ 32.103074] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:38 dell580 kernel: [ 32.103085] ata2.00: hard resetting link Apr 2 16:51:38 dell580 kernel: [ 32.419669] ata2.01: hard resetting link Apr 2 16:51:39 dell580 kernel: [ 32.894518] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.894533] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.926536] ata2.00: configured for UDMA/100 Apr 2 16:51:39 dell580 kernel: [ 32.934715] ata2.01: configured for UDMA/133 Apr 2 16:51:39 dell580 kernel: [ 32.935578] ata2: EH complete Here's the output of smartctl for the drive. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.0.0-17-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT Device Model: SAMSUNG HD103UJ Serial Number: S13PJ90QC19706 LU WWN Device Id: 5 0000f0 00b1c7960 Firmware Version: 1AA01113 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3b Local Time is: Mon Apr 2 17:13:48 2012 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 41) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: (11772) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 197) minutes. Conveyance self-test routine recommended polling time: ( 21) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 076 076 011 Pre-fail Always - 7940 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 521 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 642 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 482 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 759 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 073 069 000 Old_age Always - 27 (Min/Max 16/27) 194 Temperature_Celsius 0x0022 073 067 000 Old_age Always - 27 (Min/Max 16/28) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 320028 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 099 099 000 Old_age Always - 1494 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 211 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 211 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 0f 31 63 8f e1 Error: ICRC, ABRT 15 sectors at LBA = 0x018f6331 = 26174257 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 40 62 8f e1 08 00:01:00.460 READ DMA c8 00 20 00 7c 30 e0 08 00:01:00.450 READ DMA c8 00 00 10 49 8f e1 08 00:01:00.440 READ DMA c8 00 e0 20 d0 30 e0 08 00:01:00.420 READ DMA c8 00 00 c0 59 90 e1 08 00:01:00.400 READ DMA Error 210 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 cf e9 cf 66 e0 Error: ICRC, ABRT 207 sectors at LBA = 0x0066cfe9 = 6737897 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 b8 cf 66 e0 08 00:08:29.780 READ DMA c8 00 60 60 c9 18 e0 08 00:08:29.770 READ DMA c8 00 40 20 c9 18 e0 08 00:08:29.770 READ DMA c8 00 20 00 c9 18 e0 08 00:08:29.760 READ DMA c8 00 20 98 cf 66 e0 08 00:08:29.750 READ DMA Error 209 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 2f d1 74 e0 e0 Error: ICRC, ABRT 47 sectors at LBA = 0x00e074d1 = 14709969 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 00 74 e0 e0 08 00:00:30.940 READ DMA c8 00 20 18 36 de e0 08 00:00:30.930 READ DMA c8 00 08 48 f1 dd e0 08 00:00:30.930 READ DMA c8 00 08 a8 f0 dd e0 08 00:00:30.930 READ DMA c8 00 08 90 f0 dd e0 08 00:00:30.930 READ DMA Error 208 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 7f 21 88 9d e0 Error: ICRC, ABRT 127 sectors at LBA = 0x009d8821 = 10324001 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 a0 00 88 9d e0 08 00:00:27.610 READ DMA c8 00 58 a8 e7 9c e0 08 00:00:27.610 READ DMA c8 00 00 28 e6 9c e0 08 00:00:27.610 READ DMA c8 00 00 e0 e4 9c e0 08 00:00:27.610 READ DMA c8 00 00 90 e0 9c e0 08 00:00:27.600 READ DMA Error 207 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 26 6a 6a c3 e0 Error: ABRT at LBA = 0x00c36a6a = 12806762 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- ca 00 00 90 69 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 68 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 50 65 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 d0 64 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 63 c3 e0 08 00:29:39.350 WRITE DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Interrupted (host reset) 90% 638 - # 2 Short offline Interrupted (host reset) 90% 638 - # 3 Extended offline Interrupted (host reset) 90% 638 - # 4 Short offline Interrupted (host reset) 90% 638 - # 5 Extended offline Interrupted (host reset) 90% 638 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • IIS6 Log time recording problems

    - by Hafthor
    On three separate occasions on two separate servers at nearly the same times, 6.9 hours seemingly went by without any data being written to the IIS logs, but, on closer inspection, it appears that it was all recorded all at once. Here's the facts as I know them: Windows Server 2003 R2 w/ IIS6 Logging using GMT, server local time GMT-7. Application was still operating and I have SQL data to prove that Time gaps appear in log file, not across two # headers appear at gap Load balancer pings every 30 seconds No caching Here's info on a particular case: an entry appears for 2009-09-21 18:09:27 then #headers the next entry is for 2009-09-22 01:21:54, and so are the next 1600 entries in this log file and 370 in the next log file. about half of the ~2000 entries on 2009-09-22 01:21:54 are load balancer pings (est. at 2/min for 6.9hrs = 828 pings) then entries are recorded as normal. I believe that these events may coincide with me deploying an ASP.NET application update into those machines. Here's some relevant content from the logs in question: ex090921.log line 3684 2009-09-21 17:54:40 GET /ping.aspx - 80 404 0 0 3733 122 0 2009-09-21 17:55:11 GET /ping.aspx - 80 404 0 0 3733 122 0 2009-09-21 17:55:42 GET /ping.aspx - 80 404 0 0 3733 122 0 2009-09-21 17:56:13 GET /ping.aspx - 80 404 0 0 3733 122 0 2009-09-21 17:56:45 GET /ping.aspx - 80 404 0 0 3733 122 0 #Software: Microsoft Internet Information Services 6.0 #Version: 1.0 #Date: 2009-09-21 18:04:37 #Fields: date time cs-method cs-uri-stem cs-uri-query s-port sc-status sc-substatus sc-win32-status sc-bytes cs-bytes time-taken 2009-09-22 01:04:06 GET /ping.aspx - 80 404 0 0 3733 122 3078 2009-09-22 01:04:06 GET /ping.aspx - 80 404 0 0 3733 122 109 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 278 122 3828 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 278 122 0 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 278 122 0 ... continues until line 5449 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 277 122 0 <eof> ex090922.log #Software: Microsoft Internet Information Services 6.0 #Version: 1.0 #Date: 2009-09-22 00:00:16 #Fields: date time cs-method cs-uri-stem cs-uri-query s-port sc-status sc-substatus sc-win32-status sc-bytes cs-bytes time-taken 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 277 122 0 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 277 122 0 ... continues until line 367 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 277 122 0 2009-09-22 01:04:30 GET /ping.aspx - 80 200 0 0 277 122 0 ... back to normal behavior Note the seemingly correct date/time written to the #header of the new log file. Also note that /ping.aspx returned 404 then switched to 200 just as the problem started. I rename the "I'm alive page" so the load balancer stops sending requests to the server while I'm working on it. What you see here is me renaming it back so the load balancer will use the server. So, this problem definitely coincides with me re-enabling the server. Any ideas?

    Read the article

  • IIS6 Log time recording problems

    - by Hafthor
    On three separate occasions on two separate servers at nearly the same times, 6.9 hours seemingly went by without any data being written to the IIS logs, but, on closer inspection, it appears that it was all recorded all at once. Here's the facts as I know them: Windows Server 2003 R2 w/ IIS6 Logging using GMT, server local time GMT-7. Application was still operating and I have SQL data to prove that Time gaps appear in log file, not across two # headers appear at gap Load balancer pings every 30 seconds No caching Here's info on a particular case: an entry appears for 2009-09-21 18:09:27 then #headers the next entry is for 2009-09-22 01:21:54, and so are the next 1600 entries in this log file and 370 in the next log file. about half of the ~2000 entries on 2009-09-22 01:21:54 are load balancer pings (est. at 2/min for 6.9hrs = 828 pings) then entries are recorded as normal. I believe that these events may coincide with me deploying an ASP.NET application update into those machines. Here's some relevant content from the logs in question: ex090921.log line 3684 2009-09-21 17:54:40 GET /ping.aspx - 80 404 0 0 3733 122 0 2009-09-21 17:55:11 GET /ping.aspx - 80 404 0 0 3733 122 0 2009-09-21 17:55:42 GET /ping.aspx - 80 404 0 0 3733 122 0 2009-09-21 17:56:13 GET /ping.aspx - 80 404 0 0 3733 122 0 2009-09-21 17:56:45 GET /ping.aspx - 80 404 0 0 3733 122 0 #Software: Microsoft Internet Information Services 6.0 #Version: 1.0 #Date: 2009-09-21 18:04:37 #Fields: date time cs-method cs-uri-stem cs-uri-query s-port sc-status sc-substatus sc-win32-status sc-bytes cs-bytes time-taken 2009-09-22 01:04:06 GET /ping.aspx - 80 404 0 0 3733 122 3078 2009-09-22 01:04:06 GET /ping.aspx - 80 404 0 0 3733 122 109 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 278 122 3828 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 278 122 0 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 278 122 0 ... continues until line 5449 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 277 122 0 <eof> ex090922.log #Software: Microsoft Internet Information Services 6.0 #Version: 1.0 #Date: 2009-09-22 00:00:16 #Fields: date time cs-method cs-uri-stem cs-uri-query s-port sc-status sc-substatus sc-win32-status sc-bytes cs-bytes time-taken 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 277 122 0 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 277 122 0 ... continues until line 367 2009-09-22 01:04:06 GET /ping.aspx - 80 200 0 0 277 122 0 2009-09-22 01:04:30 GET /ping.aspx - 80 200 0 0 277 122 0 ... back to normal behavior Note the seemingly correct date/time written to the #header of the new log file. Also note that /ping.aspx returned 404 then switched to 200 just as the problem started. I rename the "I'm alive page" so the load balancer stops sending requests to the server while I'm working on it. What you see here is me renaming it back so the load balancer will use the server. So, this problem definitely coincides with me re-enabling the server. Any ideas?

    Read the article

  • What IDE to use for Python

    - by husayt
    As a Python newbie, it is interesting to know what IDE's ("GUIs/editors") others use for Python coding. If you can just give the name (e.g. Textpad, Eclipse ..) that will be enough. If it is already mentioned, you can just vote for it. But if you can also give some more comparative information, that will be much appreciated. Thanks. Update: Results so far PyDev with Eclipse (CP, F, AC, PD, EM, SI, MLS, UML, SC, UT, LN, CF, BM) Komodo (CP, C/F, MLS, PD, AC, SC, SI, BM, LN, CF, CT) Emacs (CP, F, AC, MLS, PD, EM, SC, SI, BM, LN, CF, CT, UT, UML) Vim (CP, F, AC, MLS, SI, BM, LN, CF ) TextMate (Mac, CT, CF, MLS, SI, BM, LN) Gedit (Linux, F, AC, MLS, BM, LN, CT [sort of]) Idle (CP, F, AC) PIDA (Linux, CP, F, AC, MLS, SI, BM, LN, CF)(VIM Based) NotePad++ (Windows) BlueFish (Linux) JEdit (CP, F, BM, LN, CF, MLS) E-Texteditor (TextMate Clone for Windows) WingIde (CP, C, AC, MLS (support for C), PD, EM, SC, SI, BM, LN, CF, CT, UT) Eric Ide (CP, F, AC, PD, EM, SI, LN, CF, UT) Pyscripter (Windows, F, AC, PD, EM, SI, LN, CT, UT) ConTEXT (Windows, C) SPE (F, AC, UML) SciTE (CP, F, MLS, EM, BM, LN, CF, CT, SH) Zeus (W, C, BM, LN, CF, SI, SC, CT) NetBeans (CP, F, PD, UML, AC, MLS, SC, SI, BM, LN, CF, CT, UT, RAD) DABO (CP) BlackAdder (C, CP, CF, SI) PythonWin (W, F, AC, PD, SI, BM, CF) Geany (CP, F, very limited AC, MLS, SI, BM, LN, CF) UliPad (CP, F, AC, PD, MLS, SI, LI, CT, UT, BM) Boa Constructor (CP, F, AC, PD, EM, SI, BM, LN, UML, CF, CT) ScriptDev (W, C, AC, MLS, PD, EM, SI, BM, LN, CF, CT) Spider (CP, F, AC) Editra (CP, F, AC, MLS, SC, SI, BM, LN, CF) Pfaide (Windows, C, AC, MLS, SI, BM, LN, CF, CT) KDevelop (CP, F, MLS, SC, SI, BM, LN, CF) Acronyms used: CP - Cross Platfom C - Commercial F - Free AC - Automatic Code-completion MLS - Multi-Language Support PD - Integrated Python Debugging EM - ErrorMarkup SC - Source Control integration SI - Smart Indent BM - Bracket Matching LN - Line Numbering UML - UML editing / viewing CF - Code Folding CT - Code Templates UT - Unit Testing UID - Gui Designer (e.g. QT, Eric, ..) DB - integrated database support RAD - Rapid app development support I don't mention basics like Syntax highlighting as I expect these by default. This is a just dry list reflecting your feedback and comments, I am not advocating any of these tools. I will keep updating this list as you keep posting your answers. PS. Can you help me to add features of the above editors to the list (like autocomplete, debugging, or etc)?

    Read the article

  • SocketChannel in Java sends data, but it doesn't get to destination application

    - by Peterson
    Hi Everybody, I'm suffering a lot to create a simple ChatServer in Java, using the NIO libraries. Wonder if someone could help me. I am doing that by using SocketChannel and Selector to handle multiple clients in a single thread. The problem is: I am able to accept new connections and get it's data, but when I try to send data back, the SocketChannel simply doesn't work. In the method write(), it returns a integer that is the same size of the data i'm passing to it, but the client never receives that data. Strangely, when I close the server application, the client receives the data. It's like the socketchannel maintains a buffer, and it only get flushed when I close the application. Here are some more details, to give you more information to help. I'm handling the events in this piece of code: private void run() throws IOException { ServerSocketChannel ssc = ServerSocketChannel.open(); // Set it to non-blocking, so we can use select ssc.configureBlocking( false ); // Get the Socket connected to this channel, and bind it // to the listening port this.serverSocket = ssc.socket(); InetSocketAddress isa = new InetSocketAddress( this.port ); serverSocket.bind( isa ); // Create a new Selector for selecting this.masterSelector = Selector.open(); // Register the ServerSocketChannel, so we can // listen for incoming connections ssc.register( masterSelector, SelectionKey.OP_ACCEPT ); while (true) { // See if we've had any activity -- either // an incoming connection, or incoming data on an // existing connection int num = masterSelector.select(); // If we don't have any activity, loop around and wait // again if (num == 0) { continue; } // Get the keys corresponding to the activity // that has been detected, and process them // one by one Set keys = masterSelector.selectedKeys(); Iterator it = keys.iterator(); while (it.hasNext()) { // Get a key representing one of bits of I/O // activity SelectionKey key = (SelectionKey)it.next(); // What kind of activity is it? if ((key.readyOps() & SelectionKey.OP_ACCEPT) == SelectionKey.OP_ACCEPT) { // Aceita a conexão Socket s = serverSocket.accept(); System.out.println( "LOG: Conexao TCP aceita de " + s.getInetAddress() + ":" + s.getPort() ); // Make sure to make it non-blocking, so we can // use a selector on it. SocketChannel sc = s.getChannel(); sc.configureBlocking( false ); // Registra a conexao no seletor, apenas para leitura sc.register( masterSelector, SelectionKey.OP_READ ); } else if ( key.isReadable() ) { SocketChannel sc = null; // It's incoming data on a connection, so // process it sc = (SocketChannel)key.channel(); // Verifica se a conexão corresponde a um cliente já existente if((clientsMap.getClient(key)) != null){ boolean closedConnection = !processIncomingClientData(key); if(closedConnection){ int id = clientsMap.getClient(key); closeClient(id); } } else { boolean clientAccepted = processIncomingDataFromNewClient(key); if(!clientAccepted){ // Se o cliente não foi aceito, sua conexão é simplesmente fechada sc.socket().close(); sc.close(); key.cancel(); } } } } // We remove the selected keys, because we've dealt // with them. keys.clear(); } } This piece of code is simply handles new clients that wants to connect to the chat. So, a client makes a TCP connection to the server, and once it gets accepted, it sends data to the server following a simply text protocol, informing his id and asking to get registrated to the server. I handle this in the method processIncomingDataFromNewClient(key). I'm also keeping a map of clients and its connections in a data structure similar to a hashtable. I? doing that because I need to recover a client Id from a connection and a connection from a client Id. This is can be shown in: clientsMap.getClient(key). But the problem itself resides in the method processIncomingDataFromNewClient(key). There, I simply read the data that the client sent to me, validate it, and if it's ok, I send a message back to the client to tell that it is connected to the chat server. Here is a similar piece of code: private boolean processIncomingDataFromNewClient(SelectionKey key){ SocketChannel sc = (SocketChannel) key.channel(); String connectionOrigin = sc.socket().getInetAddress() + ":" + sc.socket().getPort(); int id = 0; //id of the client buf.clear(); int bytesRead = 0; try { bytesRead = sc.read(buf); if(bytesRead<=0){ System.out.println("Conexão fechada pelo: " + connectionOrigin); return false; } System.out.println("LOG: " + bytesRead + " bytes lidos de " + connectionOrigin); String msg = new String(buf.array(),0,bytesRead); // Do validations with the client sent me here // gets the client id }catch (Exception e) { e.printStackTrace(); System.out.println("LOG: Oops. Cliente não conhece o protocolo. Fechando a conexão: " + connectionOrigin); System.out.println("LOG: Primeiros 10 caracteres enviados pelo cliente: " + msg); return false; } } } catch (IOException e) { System.out.println("LOG: Erro ao ler dados da conexao: " + connectionOrigin); System.out.println("LOG: "+ e.getLocalizedMessage()); System.out.println("LOG: Fechando a conexão..."); return false; } // If it gets to here, the protocol is ok and we can add the client boolean inserted = clientsMap.addClient(key, id); if(!inserted){ System.out.println("LOG: Não foi possível adicionar o cliente. Ou ele já está conectado ou já têm clientes demais. Id: " + id); System.out.println("LOG: Fechando a conexão: " + connectionOrigin); return false; } System.out.println("LOG: Novo cliente conectado! Enviando mesnsagem de confirmação. Id: " + id + " Conexao: " + connectionOrigin); /* Here is the error */ sendMessage(id, "Servidor pet: connection accepted"); System.out.println("LOG: Novo cliente conectado! Id: " + id + " Conexao: " + connectionOrigin); return true; } And finally, the method sendMessage(SelectionKey key) looks like this: private void sendMessage(int destId, String msg) { Charset charset = Charset.forName("ISO-8859-1"); CharBuffer charBuffer = CharBuffer.wrap(msg, 0, msg.length()); ByteBuffer bf = charset.encode(charBuffer); //bf.flip(); int bytesSent = 0; SelectionKey key = clientsMap.getClient(destId); SocketChannel sc = (SocketChannel) key.channel(); try { / int total_bytes_sent = 0; while(total_bytes_sent < msg.length()){ bytesSent = sc.write(bf); total_bytes_sent += bytesSent; } System.out.println("LOG: Bytes enviados para o cliente " + destId + ": "+ total_bytes_sent + " Tamanho da mensagem: " + msg.length()); } catch (IOException e) { System.out.println("LOG: Erro ao mandar mensagem para: " + destId); System.out.println("LOG: " + e.getLocalizedMessage()); } } So, what is happening is that the server, when send a message, prints something like this: LOG: Bytes sent to the client: 28 Size of the message: 28 So, it tells that it sent the data, but the chat client keeps blocking, waiting in the recv() method. So, the data never gets to it. When I close the server application, though, all the data appears in the client. I wonder why. It is important to say that the client is in C and the server JAVA, and I'm running both in the same machine, an Ubuntu Guest in virtualbox under windows. I also run both under windows host and under linuxes hosts, and keep getting the same strange problem. I'm sorry for the great lenght of this question, but I already searched a lot of places for an answer, found a lot of tutorials and questions, including here at StackOverflow, but coundn't find a reasonable explanation. I am really not liking this Java NIO, and i saw a lot of people complaining about it too. I am thinking that if I had done that in C it would have been a lot easier :-D So, if someone could help me and even discuss this behavor, it would be great! :-) Thanks everybody in advance, Péterson

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >