  • Linux - real-world hardware RAID controller tuning (scsi and cciss)

    - by ewwhite
    Most of the Linux systems I manage feature hardware RAID controllers (mostly HP Smart Array). They're all running RHEL or CentOS. I'm looking for real-world tunables to help optimize performance for setups that incorporate hardware RAID controllers with SAS disks (Smart Array, Perc, LSI, etc.) and battery-backed or flash-backed cache. Assume RAID 1+0 and multiple spindles (4+ disks). I spend a considerable amount of time tuning Linux network settings for low-latency and financial trading applications. But many of those options are well-documented (changing send/receive buffers, modifying TCP window settings, etc.). What are engineers doing on the storage side? Historically, I've made changes to the I/O scheduling elevator, recently opting for the deadline and noop schedulers to improve performance within my applications. As RHEL versions have progressed, I've also noticed that the compiled-in defaults for SCSI and CCISS block devices have changed as well. This has had an impact on the recommended storage subsystem settings over time. However, it's been awhile since I've seen any clear recommendations. And I know that the OS defaults aren't optimal. For example, it seems that the default read-ahead buffer of 128kb is extremely small for a deployment on server-class hardware. The following articles explore the performance impact of changing read-ahead cache and nr_requests values on the block queues. http://zackreed.me/articles/54-hp-smart-array-p410-controller-tuning http://www.overclock.net/t/515068/tuning-a-hp-smart-array-p400-with-linux-why-tuning-really-matters http://yoshinorimatsunobu.blogspot.com/2009/04/linux-io-scheduler-queue-size-and.html For example, these are suggested changes for an HP Smart Array RAID controller: echo "noop" > /sys/block/cciss\!c0d0/queue/scheduler blockdev --setra 65536 /dev/cciss/c0d0 echo 512 > /sys/block/cciss\!c0d0/queue/nr_requests echo 2048 > /sys/block/cciss\!c0d0/queue/read_ahead_kb What else can be reliably tuned to improve storage performance? I'm specifically looking for sysctl and sysfs options in production scenarios.

    Read the article

  • HP Smart Array; Is it possible to convert Raid1 to Raid0 by dropping a failed drive?

    - by Erik Heppler
    I have a server that was running two 60GB drives as a logical RAID1. At some point the second drive was physically removed and the logical drive has been in "Interim Recovery Mode" for several months now. There's no need for the redundancy of RAID1 on this machine, and I have no intention of replacing the missing drive. If possible I would like to convert the current RAID1 to a single-drive RAID0 by simply dropping the failed drive from the current configuration. I'm only interested in doing this if it can be done in-place. Otherwise I'm perfectly content to leave it in "Interim Recovery Mode" indefinitely.

    Read the article

  • Proliant server will not accept new hard disks in RAID 1+0?

    - by Leigh
    I have a HP ProLiant DL380 G5, I have two logical drives configured with RAID. I have one logical drive RAID 1+0 with two 72 gb 10k sas 1 port spare no 376597-001. I had one hard disk fail and ordered a replacement. The configuration utility showed error and would not rebuild the RAID. I presumed a hard disk fault and ordered a replacement again. In the mean time I put the original failed disk back in the server and this started rebuilding. Currently shows ok status however in the log I can see hardware errors. The new disk has come and I again have the same problem of not accepting the hard disk. I have updated the P400 controller with the latest firmware 7.24 , but still no luck. The only difference I can see is the original drive has firmware 0103 (same as the RAID drive) and the new one has HPD2. Any advice would be appreciated. Thanks in advance Logs from server ctrl all show config Smart Array P400 in Slot 1 (sn: PAFGK0P9VWO0UQ) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.5 GB, RAID 1, Interim Recovery Mode) physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 73.5 GB, OK) physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, Failed array B (SAS, Unused Space: 0 MB) logicaldrive 2 (558.7 GB, RAID 5, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK) ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: PAFGK0P9VWO0UQ Cache Serial Number: PA82C0J9VWL8I7 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: E Firmware Version: 7.24 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Status Details: A cache error was detected. Run more information. Cache Ratio: 100% Read / 0% Write Drive Write Cache: Disabled Total Cache Size: 256 MB Total Cache Memory Available: 208 MB No-Battery Write Cache: Disabled Battery/Capacitor Count: 0 SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 0 MB Status: Failed Physical Drive Array Type: Data One of the drives on this array have failed or has Logical Drive: 1 Size: 68.5 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 17594 Strip Size: 128 KB Full Stripe Size: 128 KB Status: Interim Recovery Mode Caching: Enabled Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive0 Mount Points: C:\ 68.5 GB Logical Drive Label: A0100539PAFGK0P9VWO0UQ0E93 Mirror Group 0: physicaldrive 2I:1:2 (port 2I:box 1:bay 2, S Mirror Group 1: physicaldrive 2I:1:1 (port 2I:box 1:bay 1, S Drive Type: Data physicaldrive 2I:1:1 Port: 2I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 73.5 GB Rotational Speed: 10000 Firmware Revision: 0103 Serial Number: B379P8C006RK Model: HP DG072A9B7 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:2 Port: 2I Box: 1 Bay: 2 Status: Failed Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: D5A1PCA04SL01244 Model: HP EH0072FARUA PHY Count: 2 PHY Transfer Rate: Unknown, Unknown Array: B Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data Logical Drive: 2 Size: 558.7 GB Fault Tolerance: RAID 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 64 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Parity Initialization Status: Initialization Co Unique Identifier: 600508B10010503956574F305551 Disk Name: \\.\PhysicalDrive1 Mount Points: E:\ 558.7 GB Logical Drive Label: AF14FD12PAFGK0P9VWO0UQD007 Drive Type: Data physicaldrive 1I:1:5 Port: 1I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE07QH300009923X1X3 Model: HP DG0300BALVP Current Temperature (C): 32 Maximum Temperature (C): 45 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:3 Port: 2I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE0AHVH00009924P8F3 Model: HP DG0300BALVP Current Temperature (C): 34 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown physicaldrive 2I:1:4 Port: 2I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: 3SE08NAK00009924KWD6 Model: HP DG0300BALVP Current Temperature (C): 35 Maximum Temperature (C): 47 PHY Count: 2 PHY Transfer Rate: Unknown, Unknown

    Read the article

  • VMWare ESXi 5 - Expanded RAID 5 array - cannot access datastore

    - by Dayton Brown
    I'm using VMWare ESXi 5 and had a 2 TB RAID 5 setup on an HP DL360 with a P400i RAID card. I added two more 1 TB drives and using the SmartStart ACU, added the drives and expanded the logical disk. Now after booting back to ESXi, the server boots, but lists no available persistent storage. I've rescanned multiple times to no avail: the Datastore doesn't show up. I booted to GParted and the 1.8TB partition shows up, but it shows as unknown. Anyone have any good ideas? EDIT: Final Solution So after much gnashing of teeth, it was fairly simple to solve. I purchased an eSata 2 TB external drive and a PCI eSata card for my server. I then used Clonezilla to image the current partitions to my new external drive. You have to check "don't check drive sizes" in advanced mode, otherwise it will yell at you for have a smaller drive. For some reason my PCI card wouldn't boot on my HP server, so I hooked the drive up to another desktop I had, booted to VMWare, and copied the vmdk's to another drive. I'm going to blow out the RAID config and then create 1.5TB logical drives.

    Read the article

  • Reusing Raid 5 Drive?

    - by User125
    We have two servers (ML530 G2 and DL380G2) w/ identical HP 10K RPM SCSI drives w/ a raid 5. One is decommissioned and the other will be decommissioned shortly. However, one of the drives on the production server had a drive failure. My hope was to take one of the drives from the decommissioned server and pop it into the production server. Both are running RAID 5. I broke the array on the decomm. server. To my knowledge, that should have wiped out all the volume and partition information. However, I do not know if it is safe to then take a drive from the decomm'ed server and replace the failed drive. Will the existing array see it as a replacement drive, wipe it and rebuild? Or will it fail because it was used in an array before. Are there any remnant data that resides on the drives after deleting a raid 5 array? These servers are 10-15 years old, so we're just trying to keep them alive until we decommission it. I'm not looking to pay a premium to find a vendor that still sells replacement drives for this system.

    Read the article

  • HP DL380 G5 Predictive failure of a new drive

    - by CharlieJ
    Consolidated Error Report: Controller: Smart Array P400 in slot 3 Device: Physical Drive 1I:1:1 Message: Predictive failure. We have an HP DL380 G5 server with two 72GB 15k SAS drives configured in RAID1. A couple weeks ago, the server reported a drive failure on Drive 1. We replaced the drive with a brand new HDD -- same spares number. A few days ago, the server started reporting a predictive drive failure on the new drive, in the same bay. Is it likely the new drive is bad... or more likely we have a bay failure problem? This is a production server, so any advice would be appreciated. I have another spare drive, so I can hot swap it if this is a fluke and new drive is just bad. THANKS! CharlieJ

    Read the article

  • High IO latency on ESXi 4.1 on HP DL580 G7

    - by teddydestodes
    at my Company we were experiencing some weird spikes on IO latency on one of our ESXi instances. we've spend 24h figuring out whats wrong and no clue so far. after giving up we put all the disks into a different server (HP DL380 G7) with much less RAM and only one 6(HT) cores (from 12 on the DL 580) which run fine for about 2 hours. I dont know the specs for the DL380 but both servers have a Smart Array P410i with BBWC (the DL 580 has 1GB) Is it possible that one(or all) of the disks is failing without actually failing?

    Read the article

  • p410i Mirror failed couldnt find same disk

    - by Heishiro Mitsurugi
    I have an HP server with an P410i RAID Card installed. I had two SATA Drives connected (250GB each). The RAID was configured as a Mirror. A few days ago the drive one (1) failed, and i had to remove it. Tried to find the same part number here in Venezuela, but i couldn't. So, i bought a 500GB SATA Drive, and connected it to the same bay where the 250GB failed drive was. When the server booted, it asked me if i wanted to rebuild the data. I selected the option for that, and Windows Server restarted properly. When i got into the ACU (Array Configuration Utility) it told me that it was rebuilding the data. Today the warning went away, and according to the ACU everything is just fine. My question is... What i did was right? Can i create a mirror from a 250GB disk in a 500GB disk using the p410i? I have done that before, but only using software RAID in Windows, and it just uses the space it needs. As a matter of fact, when did that using Windows i was able to use the remaining space in the bigger drive, but in the p410i i can't use it. Should i be worried? Thanks a lot in advance for any pointers or info that you could give on this. Heishiro

    Read the article

  • Can different drive speeds and sizes be used in a hardware RAID configuration w/o affecting performance?

    - by R. Dill
    Specifically, I have a RAID 1 array configuration with two 500gb 7200rpm SATA drives mirrored as logical drive 1 (a) and two of the same mirrored as logical drive 2 (b). I'd like to add two 1tb 5400rpm drives in the same mirrored fashion as logical drive 3 (c). These drives will only serve as file storage with occasional but necessary access, and therefore, space is more important than speed. In researching whether this configuration is doable, I've been told and have read that the array will only see the smallest drive size and slowest speed. However, my understanding is that as long as the pairs themselves aren't mixed (and in this case, they aren't) that the array should view and use all drives at their actual speed and size. I'd like to be sure before purchasing the additional drives. Insight anyone?

    Read the article