Search Results

Search found 1086 results on 44 pages for 'switches'.

Page 2/44 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Switches with large MAC address table?

    - by user1290200
    Does anyone know which switches have a large MAC address table ? I see most switches having only 8K, but we need to store way, way more than that (hundreds of K). I know this may seem odd, but trust me, there's no other way we can make our setup work. The only thing we seem to be able to do is install Juniper routers that store up to 1M addresses, but that will get quite costly and we'd rather avoid doing that.

    Read the article

  • How does Windows 7 detect my switches?

    - by Daniel
    I notices in the Network overview of Windows 7 that my switches are found on the path to the gateway, which baffled me completely. The last time I checked they just took the ethernet packages and transported them to the "right" location. How does this switch detection work? Do switches alter the packages? Do they react on ICMP messages?

    Read the article

  • Context switches much slower in new linux kernels

    - by Michael Goldshteyn
    We are looking to upgrade the OS on our servers from Ubuntu 10.04 LTS to Ubuntu 12.04 LTS. Unfortunately, it seems that the latency to run a thread that has become runnable has significantly increased from the 2.6 kernel to the 3.2 kernel. In fact the latency numbers we are getting are hard to believe. Let me be more specific about the test. We have a program that has two threads. The first thread gets the current time (in ticks using RDTSC) and then signals a condition variable once a second. The second thread waits on the condition variable and wakes up when it is signaled. It then gets the current time (in ticks using RDTSC). The difference between the time in the second thread and the time in the first thread is computed and displayed on the console. After this the second thread waits on the condition variable once more. So, we get a thread to thread signaling latency measurement once a second as a result. In linux 2.6.32, this latency is somewhere on the order of 2.8-3.5 us, which is reasonable. In linux 3.2.0, this latency is somewhere on the order of 40-100 us. I have excluded any differences in hardware between the two host hosts. They run on identical hardware (dual socket X5687 {Westmere-EP} processors running at 3.6 GHz with hyperthreading, speedstep and all C states turned off). We are changing the affinity to run both threads on physical cores of the same socket (i.e., the first thread is run on Core 0 and the second thread is run on Core 1), so there is no bouncing of threads on cores or bouncing/communication between sockets. The only difference between the two hosts is that one is running Ubuntu 10.04 LTS with kernel 2.6.32-28 (the fast context switch box) and the other is running the latest Ubuntu 12.04 LTS with kernel 3.2.0-23 (the slow context switch box). Have there been any changes in the kernel that could account for this ridiculous slow down in how long it takes for a thread to be scheduled to run?

    Read the article

  • Toshiba laptop overheats and switches off

    - by Qazase
    Since upgrading to 11.10 from 11.04 my laptop rapidly heats up and eventually turns off by itself (due to the intense heat I presume). This was not happening whilst running 11.04; I opted then to run gnome rather then unity, not sure if this makes a differences. Was hoping to solve this problem as it worries me that this continues to happen. if anyone can help me, or i need to provide more information on my system please provide step by step instructions on how to do this as I am still a beginner to the linux platform.

    Read the article

  • Port mirroring on multiple switches

    - by Matt
    So here is the deal, I have a server on switch A where port 3 is monitoring traffic for most of the ports on switch A. However I have other users on switch B that needs to have port 3 on switch A monitor as well. Is this possible? I have been reading about rspan but doesnt seem to work. Switch A: monitor session 1 source interface fast0/1 - 2 monitor session 1 source interface fast0/4 - 46 monitor session 1 destination interface fast0/3 (this works great for switch A, I need a solution to get switch B to also have some ports sent to port 3 on switch A for monitoring.) Onxx, All the traffic on switch A is fine, there will be about 10-15 ports on switch B that I need to send to fa0/3 on switch A as the destination. I have the switches connected with a ethernet cable with a trunk port on both switches on port 48 on switch B and A and port 47 on A connects to our sonicwall. So I am assuming they are daisy chained? What if I did the following: Switch A monitor session 1 source interface fast0/1 - 2 monitor session 1 source interface fast0/4 - 46 monitor session 1 destination interface fast0/3 Put all of the ports on vlan 10 because I made an rspan vlan 10 On switch B monitor the ports I need will say 1-10 monitor session 1 source interface fast0/1 - 10 monitor session 1 destination remote vlan 10 as a prerequisite I would have created vlan 10 as a rspan vlan on switch B. Switch A Monitor session 1 destination remote vlan 10 Would this work? By the way I am working with cisco catalyst 3560 switches.

    Read the article

  • I can't get router and switches configured properly for my home office network

    - by BernicusMaximus
    Networking Gurus, I recently built a new detached garage, with an office above. As such I had it tied into my existing home ethernet wiring. The ethernet signal is coming into the garage just fine, but I can not get my network configured the way I want because of problems trying to link the various router/switch devices. Please see the following links for the network diagrams: Home Network So basically, I can't my future state to work. I'm not sure if I'm using incompatible switches or what, but I tried the future state with some 4 port switches from best buy and had no luck. I resorted to setting up the Current State so I could operate. What I am looking for is help on how best to get my future state to work. Is this possible with my current configuration, and if not, what should I do? Any help is appreciated. Thanks, Bernie

    Read the article

  • 2 HP Procurve 4000M switches and Comcast SMC Gateway

    - by Cole Tierney
    We've got 2 HP Procurve 4000M switches joined by a trunk. Switch 1 is connected to a Cisco 2600 router which is connected to a T1. Internet traffic for hosts on switch 2 must pass through the trunk to switch 1. We're now switching to Comcast who's given us 4 port SMC router. I would like to connect each switch to the comcast router to reduce traffic on the trunk, but I don't want to create a loop. The switches support spanning tree protocol, but I don't know how this would work with the comcast router. Would a triangle network like this work? Thanks for any tips.

    Read the article

  • Trying to understand why VLANs need to be created on intermediate switches

    - by Jon Reeves
    I'm currently studying for the Cisco switching exam and having trouble understanding exactly how 802.1q tagging works. Given three daisy chained switches (A,B, and C) with trunk ports between them and VLAN 101 defined on both end switches (A and C), I'm not sure why the VLAN also needs to be defined on the middle one (B)? Note that I am not disputing that it does need to be configured, I'm just trying to understand why exactly. As I understand it, traffic from VLAN 101 on switch A will be tagged as it goes through the trunk to switch B. According to the documentation I have read, trunks will pass all VLANs by default, and the .1q tag is only removed when the frame leaves through an access port on the relevant VLAN. From this I would expect switch B to simply forward the tagged frame unchanged through the trunk to switch C. Can anyone shed some light on how switch B processes this frame and why it does not get forwarded through the other trunk ?

    Read the article

  • Cascading KVM switches

    - by einpoklum
    I have a not-so-small number of computers (say, 5) which I want to access with a single keyboard, USB and monitor. I can get an 8-port KVM switch, which is a pretty expensive piece of hardware; however, in theory, I should be able to cascade KVM switches: Have one 4-port KVM switch between 2 other KVMs (a 2-port and a 4-port). Is this doable (with typical off-the-shelf switches and cables)? Has anyone had experience doing this? Note: I'm interested in USB-only for the keyboard and mouse, and either VGA or DVI for the display. Audio and PS/2 connections are irrelevant for me..

    Read the article

  • HP ProCurve & Cisco switches interoperability

    - by Kamil Z
    I have a couple of questions regarding Cisco and HP ProCurve interoperability. Here's a link to pdf with my network topology. Can someone help me with basic VLAN configuration in such topology? Below there are some details of my configuration: # m_management_2 interface FastEthernet0/43 switchport access vlan 250 switchport mode access spanning-tree port-priority 32 spanning-tree cost 100 # MTA2-swmgmt1 vlan 1 name "DEFAULT_VLAN" untagged 1-48 ip address 10.10.249.190 255.255.255.128 exit # MTA2-swtr1 vlan 1 name "DEFAULT_VLAN" untagged 1-14,16-48 no ip address no untagged 15 exit vlan 100 name "MTA Mgmt" untagged 15 ip address 10.10.249.188 255.255.255.128 exit # MTA2-swtr2 vlan 1 name "DEFAULT_VLAN" untagged 1-14,16-48 no ip address no untagged 15 exit vlan 100 name "MTA Mgmt" untagged 15 ip address 10.10.249.189 255.255.255.128 exit I don't post MTA2-bcsw[12] configuration, because I wasn's successfull in this one yet. Every time I configure VLANs on MTA2-bcsw[12] Fa0/24 interface on m_management_2 goes down bacause of receiving tagged BPDUs on access port (there are no VLANs configured on MTA2-swmgmt1 because of fact that only 250 VLAN is allowed in this switch. Is it correct?). Can someone provide me some basic configuration for this topology? Second thing I want to ask is concept of connection from MTA2-swmgmt1 to MTA2-swtr[12] HP switches for the sake of management. How to configure such ports on HP switches (managed switch and manager switch). Is my actual configuration correct?

    Read the article

  • Find out which task is generating a lot of context switches on linux

    - by Gaks
    According to vmstat, my Linux server (2xCore2 Duo 2.5 GHz) is constantly doing around 20k context switches per second. # vmstat 3 procs -----------memory---------- ---swap-- -----io---- -system-- ----cpu---- r b swpd free buff cache si so bi bo in cs us sy id wa 2 0 7292 249472 82340 2291972 0 0 0 0 0 0 7 13 79 0 0 0 7292 251808 82344 2291968 0 0 0 184 24 20090 1 1 99 0 0 0 7292 251876 82344 2291968 0 0 0 83 17 20157 1 0 99 0 0 0 7292 251876 82344 2291968 0 0 0 73 12 20116 1 0 99 0 ... but uptime shows small load: load average: 0.01, 0.02, 0.01 and top doesn't show any process with high %CPU usage. How do I find out what exactly is generating those context switches? Which process/thread? I tried to analyze pidstat output: # pidstat -w 10 1 12:39:13 PID cswch/s nvcswch/s Command 12:39:23 1 0.20 0.00 init 12:39:23 4 0.20 0.00 ksoftirqd/0 12:39:23 7 1.60 0.00 events/0 12:39:23 8 1.50 0.00 events/1 12:39:23 89 0.50 0.00 kblockd/0 12:39:23 90 0.30 0.00 kblockd/1 12:39:23 995 0.40 0.00 kirqd 12:39:23 997 0.60 0.00 kjournald 12:39:23 1146 0.20 0.00 svscan 12:39:23 2162 5.00 0.00 kjournald 12:39:23 2526 0.20 2.00 postgres 12:39:23 2530 1.00 0.30 postgres 12:39:23 2534 5.00 3.20 postgres 12:39:23 2536 1.40 1.70 postgres 12:39:23 12061 10.59 0.90 postgres 12:39:23 14442 1.50 2.20 postgres 12:39:23 15416 0.20 0.00 monitor 12:39:23 17289 0.10 0.00 syslogd 12:39:23 21776 0.40 0.30 postgres 12:39:23 23638 0.10 0.00 screen 12:39:23 25153 1.00 0.00 sshd 12:39:23 25185 86.61 0.00 daemon1 12:39:23 25190 12.19 35.86 postgres 12:39:23 25295 2.00 0.00 screen 12:39:23 25743 9.99 0.00 daemon2 12:39:23 25747 1.10 3.00 postgres 12:39:23 26968 5.09 0.80 postgres 12:39:23 26969 5.00 0.00 postgres 12:39:23 26970 1.10 0.20 postgres 12:39:23 26971 17.98 1.80 postgres 12:39:23 27607 0.90 0.40 postgres 12:39:23 29338 4.30 0.00 screen 12:39:23 31247 4.10 23.58 postgres 12:39:23 31249 82.92 34.77 postgres 12:39:23 31484 0.20 0.00 pdflush 12:39:23 32097 0.10 0.00 pidstat Looks like some postgresql tasks are doing 10 context swiches per second, but it doesn't all sum up to 20k anyway. Any idea how to dig a little deeper for an answer?

    Read the article

  • Sizing Switches for Storage and Production

    - by Untalented
    Couple questions. Should you always completely separate the storage network switches from production switches or are VLANs fine to segment this traffic? Is there a golden rule here? How do you properly size a switch for your environment based on the specifications the manufacturer provide (Throughput, Forwarding Throughput, Stacking Throughput, Max Mac)? If you have two switch options and one has a maximum Mac address of 8,000 vs. another with 16,0000. What does this really mean to me? How do make sure one vs. another is sized properly for me? Besides VLAN and Jumbo Frame support, is there any other "Must" haves for a virtual environments production or storage networks? There is a wealth of knowledge on sizing SANs and such, but this seems equally important and it's quite challenging to find as much information. -- Just to add some tidbits of information for the environment. This setup above is referring to the data centers which supports two different locations which have about 100 users between the two in total. The storage traffic will be iSCSI and will be 3 ESXi Hosts and one SAN housing about 2.7TB of data. Since there is currently no storage network in place (no SAN), I'm having a hard time regarding #2 to really determine what backplane throughput and switch specifications will be sufficient.

    Read the article

  • Notepad switches

    - by Homer
    What command line switches exist for Notepad? I found a few: /A <filename> opens file as ansi /W <filename> opens file as unicode /P <filename> prints filename Are there others?

    Read the article

  • cygwin running commands with switches when ssh in

    - by Troz123
    When I SSH into a Windows 2008 R2 box and try to run a command with switches like /cygdrive/c/directory/Reports.exe /ReportID=1 /DateRange=LastWeek the command just hangs and never finishes. I can see the Reports.exe spawn a process under the user but never finishes. If I RDP into the box open cygwin terminal and run the exact command it works. Any reason why I can't run the command when I SSH in?

    Read the article

  • looking for a model number recommendation for a network setup of 49 switches [closed]

    - by Bahrain Admin
    im looking to setup a site with 49 edge switches connected by fiber to a central switch. 3 VLANs will be setup to handle data, telephony, and streaming media. each edge switch should have provision for 2 SFP modules for failover, and the core switch needs to have the provision to handle this failover. i'm getting lost on the Cisco site with their specs and recommendations. if anyone could suggest a suitable model number for the core switch and the edge switch, it would be really appreciated.

    Read the article

  • .BAT Switches Parsing

    - by giiYanJ
    Erm.. I'm working with a switches parsing in BAT files, which goes like this: <commands> -a -b -x -y -z -u abc ...... The user may input a lot of switch, or none. So I used looped shift to make parsing infinite switches possible: :loop IF "%1"=="-a" ... SHIFT GOTO loop But when the script ends, I always get cmd executing the switches and showing up error like '-n' is not recognized as an internal... So, someone got any idea? Thanks a lot... P/S: Make solution sticks with BAT script if possible as using other language may cause dependencies problem as this script is aimed on ANY computer with Windows. Finally, thanks again =) EDIT: Tried shf301 suggestion, i found out that I used DEL %0 to delete itself but it seems the %0 is shifted into the arguments because of the SHIFT command.

    Read the article

  • Add power over Ethernet without new switches?

    - by dannymcc
    I need to power 16 IP phones over their Ethernet connections. I am in the process of changing our switches and only the phones need PoE, everything else is powered by mains cables. I have contacted the supplier of the phones and for 16 mains leads it will be close to £300. I know it's possible to get a PoE injector that goes between the mains and the phone but I would like to do this as tidily as possible and ideally in bulk. I imagine something that looks like a switch but doesn't actually 'switch' if that makes sense. Basically I want to inject power to 16 devices at once.

    Read the article

  • Full speed internal switch bandwidth but per-port set external bandwidth?

    - by garg
    I am in an environment where all the machines are behind a switch that I don't have access to. Each ethernet wall port has limited bandwidth depending on how much has been paid for each port. The problem is that some people have 10Mbps connections and some have 100Mbps connections and this causes problems with local intranet file transfers and operating system/software deployments. Operating systems can take hours to be deployed if the machine is on 10mbps. Do you know if it is possible with most switches to set a rule that would limit bandwidth coming in/going out to an extranet, but keep full bandwidth if the packets are destined to go to a local machine? For example, the internet might be limited to 10Mbps, but internal servers would get gigabit speeds? Thanks

    Read the article

  • Cascading switches: uplink to uplink?

    - by wuckachucka
    I'm a bit confused as to why I haven't seen any references online to using Switch A's uplink port (1Gbps, 24-port 10/100) to connect to Switch B's uplink port: everything I've seen -- including documentation, forums, articles, etc. -- has Switch A's uplink port going to one of Switch B's 10/100 access ports. As I understand it, the Uplink port (besides greater speed normally) is no different than another port except that it's "internally crossed-over" so that you can use a straight cable with it. I've also seen documentation on using the uplink port to connect a switch to a gateway router, or even a server, as it provides greater bandwidth than the access ports, but yet not sure why nobody seems to be cross-uplinking, even when there's 2 uplink ports available on some higher-end switches. Switch in question is Linksys SRW224P (x2). Am I missing something?

    Read the article

  • Switches with 802.1x "supplicant timeout" feature?

    - by chris
    I'm looking for a complete list of switches which will allow 802.1x and normal (non-supplicant) enabled hosts to connect to the same ports on a switch. This is useful for areas where there are semi-open ports such as a lobby area or a library where corporate and guest users may use the same ports but you want them to have different access profiles and where it isn't expected that guests would have 802.1x configured on their system. For instance, Enterasys and Extreme Networks both have a feature where if the switch doesn't see an EAPOL packet from the client in a certain amount of time, it puts the port into a "guest" VLAN; if it sees an 802.1x supplicant, it tries to authenticate the user via 802.1x and if they succeed, it does what the radius server tells it to do with that port (IE put the port into a certain VLAN, apply certain ACLs, etc) Do other vendors have this sort of feature, or is it expected that a switch will do both 802.1x and MAC authentication, and the "supplicant timeout" feature is implemented with a blanket allow on the MAC authentication?

    Read the article

  • Differences between Cherry mechanical keyboard switches?

    - by TreyK
    I want a comfortable, responsive mechanical switch keyboard. My only concern about mechanical switch keyboards is the noise. Boards based off of the Cherry MX Blue seem to be the loudest, but apparently offer increased tactility. I don't mind a clicky noise (I would actually prefer a bit of noise), I just don't want anything overpowering. What are the different types of Cherry mechanical switches are out there, and what separates one from the other? Also, where would I be able to test one out?

    Read the article

  • Windows Desktop Randomly Switches Resolution

    - by bobber205
    Once per log in a specific account, Windows XP is switching to 800x600 and 8 (looks like) bit color. It then after a few seconds switches back to the regular settings. This, so far, has only happened, once per log in session but it is becoming very annoying for the end user. :P Any ideas? I've tried turning off hardware acceleration as well as getting rid of her picture desktop wallpaper but nothing has made a difference. Thanks for any help!

    Read the article

  • Counting context switches per thread

    - by Sarmun
    Is there a way to see how many context switches each thread generates? (both in and out if possible) Either in X/s, or to let it run and give aggregated data after some time. (either on linux or on windows) I have found only tools that give aggregated context-switching number for whole os or per process. My program makes many context switches (50k/s), probably a lot not necessary, but I am not sure where to start optimizing, where do most of those happen.

    Read the article

  • Adding Command-Line Switches To Windows Shortcuts

    - by jaytea
    Is there a way to, in general, create a Windows shortcut to a file and instruct Windows to pass certain switches to the application before passing the filename? For example: I have an Excel file, abc.xlsx. If I want to create a shortcut to open this file read-only, I would change the target to "C:\Program Files\Microsoft Office\Office12\EXCEL.EXE" /r abc.xlsx, but this fails when another person on my network opens the shortcut and their EXCEL.EXE is not in that same folder. Surely there's a way to tell Windows to pass the /r switch without supplying the path/filename of the application that is supposed to open the file?

    Read the article

  • More interruptions than cpu context switches

    - by Christopher Valles
    I have a machine running Debian GNU/Linux 5.0.8 (lenny) 8 cores and 12Gb of RAM. We have one core permanently around 40% ~ 60% wait time and trying to spot what is happening I realized that we have more interruptions than cpu context switches. I found that the normal ratio between context switch and interruptions is around 10x more context switching than interruptions but on my server the values are completely different. backend1:~# vmstat -s 12330788 K total memory 12221676 K used memory 3668624 K active memory 6121724 K inactive memory 109112 K free memory 3929400 K buffer memory 4095536 K swap cache 4194296 K total swap 7988 K used swap 4186308 K free swap 44547459 non-nice user cpu ticks 702408 nice user cpu ticks 13346333 system cpu ticks 1607583668 idle cpu ticks 374043393 IO-wait cpu ticks 4144149 IRQ cpu ticks 3994255 softirq cpu ticks 0 stolen cpu ticks 4445557114 pages paged in 2910596714 pages paged out 128642 pages swapped in 267400 pages swapped out 3519307319 interrupts 2464686911 CPU context switches 1306744317 boot time 11555115 forks Any ideas if that is an issue? And in that case, how can I spot the cause and fix it? Update Following the instructions of the comments and focusing on the core stuck in wait I checked the processes attached to that core and below you can find the list: PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ P COMMAND 24 root RT -5 0 0 0 S 0 0.0 0:03.42 7 migration/7 25 root 15 -5 0 0 0 S 0 0.0 0:04.78 7 ksoftirqd/7 26 root RT -5 0 0 0 S 0 0.0 0:00.00 7 watchdog/7 34 root 15 -5 0 0 0 S 0 0.0 1:18.90 7 events/7 83 root 15 -5 0 0 0 S 0 0.0 1:10.68 7 kblockd/7 291 root 15 -5 0 0 0 S 0 0.0 0:00.00 7 aio/7 569 root 15 -5 0 0 0 S 0 0.0 0:00.00 7 ata/7 1545 root 15 -5 0 0 0 S 0 0.0 0:00.00 7 ksnapd 1644 root 15 -5 0 0 0 S 0 0.0 0:36.73 7 kjournald 1725 root 16 -4 16940 1152 488 S 0 0.0 0:00.00 7 udevd 2342 root 20 0 8828 1140 956 S 0 0.0 0:00.00 7 sh 2375 root 20 0 8848 1220 1016 S 0 0.0 0:00.00 7 locate 2421 root 30 10 8896 1268 1016 S 0 0.0 0:00.00 7 updatedb.findut 2430 root 30 10 58272 49m 616 S 0 0.4 0:17.44 7 sort 2431 root 30 10 3792 448 360 S 0 0.0 0:00.00 7 frcode 2682 root 15 -5 0 0 0 S 0 0.0 3:25.98 7 kjournald 2683 root 15 -5 0 0 0 S 0 0.0 0:00.64 7 kjournald 2687 root 15 -5 0 0 0 S 0 0.0 1:31.30 7 kjournald 3261 root 15 -5 0 0 0 S 0 0.0 2:30.56 7 kondemand/7 3364 root 20 0 3796 596 476 S 0 0.0 0:00.00 7 acpid 3575 root 20 0 8828 1140 956 S 0 0.0 0:00.00 7 sh 3597 root 20 0 8848 1216 1016 S 0 0.0 0:00.00 7 locate 3603 root 30 10 8896 1268 1016 S 0 0.0 0:00.00 7 updatedb.findut 3612 root 30 10 58272 49m 616 S 0 0.4 0:27.04 7 sort 3655 root 20 0 11056 2852 516 S 0 0.0 5:36.46 7 redis-server 3706 root 20 0 19832 1056 816 S 0 0.0 0:01.64 7 cron 3746 root 20 0 3796 580 484 S 0 0.0 0:00.00 7 getty 3748 root 20 0 3796 580 484 S 0 0.0 0:00.00 7 getty 7674 root 20 0 28376 1000 736 S 0 0.0 0:00.00 7 cron 7675 root 20 0 8828 1140 956 S 0 0.0 0:00.00 7 sh 7708 root 30 10 58272 49m 616 S 0 0.4 0:03.36 7 sort 22049 root 20 0 8828 1136 956 S 0 0.0 0:00.00 7 sh 22095 root 20 0 8848 1220 1016 S 0 0.0 0:00.00 7 locate 22099 root 30 10 8896 1264 1016 S 0 0.0 0:00.00 7 updatedb.findut 22108 root 30 10 58272 49m 616 S 0 0.4 0:44.55 7 sort 22109 root 30 10 3792 452 360 S 0 0.0 0:00.00 7 frcode 26927 root 20 0 8828 1140 956 S 0 0.0 0:00.00 7 sh 26947 root 20 0 8848 1216 1016 S 0 0.0 0:00.00 7 locate 26951 root 30 10 8896 1268 1016 S 0 0.0 0:00.00 7 updatedb.findut 26960 root 30 10 58272 49m 616 S 0 0.4 0:10.24 7 sort 26961 root 30 10 3792 452 360 S 0 0.0 0:00.00 7 frcode 27952 root 20 0 65948 3028 2400 S 0 0.0 0:00.00 7 sshd 30731 root 20 0 0 0 0 S 0 0.0 0:01.34 7 pdflush 31204 root 20 0 0 0 0 S 0 0.0 0:00.24 7 pdflush 21857 deploy 20 0 1227m 2240 868 S 0 0.0 2:44.22 7 nginx 21858 deploy 20 0 1228m 2784 868 S 0 0.0 2:42.45 7 nginx 21862 deploy 20 0 1228m 2732 868 S 0 0.0 2:43.90 7 nginx 21869 deploy 20 0 1228m 2840 868 S 0 0.0 2:44.14 7 nginx 27994 deploy 20 0 19372 2216 1380 S 0 0.0 0:00.00 7 bash 28493 deploy 20 0 331m 32m 16m S 4 0.3 0:00.40 7 apache2 21856 deploy 20 0 1228m 2844 868 S 0 0.0 2:43.64 7 nginx 3622 nobody 30 10 21156 10m 916 D 0 0.1 4:42.31 7 find 7716 nobody 30 10 12268 1280 888 D 0 0.0 0:43.50 7 find 22116 nobody 30 10 12612 1696 916 D 0 0.0 6:32.26 7 find 26968 nobody 30 10 12268 1284 888 D 0 0.0 1:56.92 7 find Update As suggested I take a look at /proc/interrupts and below the info there: CPU0 CPU1 CPU2 CPU3 CPU4 CPU5 CPU6 CPU7 0: 35 0 0 1469085485 0 0 0 0 IO-APIC-edge timer 1: 0 0 0 8 0 0 0 0 IO-APIC-edge i8042 8: 0 0 0 1 0 0 0 0 IO-APIC-edge rtc0 9: 0 0 0 0 0 0 0 0 IO-APIC-fasteoi acpi 12: 0 0 0 105 0 0 0 0 IO-APIC-edge i8042 16: 0 0 0 0 0 0 0 580212114 IO-APIC-fasteoi 3w-9xxx, uhci_hcd:usb1 18: 0 0 142 0 0 0 0 0 IO-APIC-fasteoi uhci_hcd:usb6, ehci_hcd:usb7 19: 9 0 0 0 0 0 0 0 IO-APIC-fasteoi uhci_hcd:usb3, uhci_hcd:usb5 21: 0 0 0 0 0 0 0 0 IO-APIC-fasteoi uhci_hcd:usb2 23: 0 0 0 0 0 0 0 0 IO-APIC-fasteoi uhci_hcd:usb4, ehci_hcd:usb8 1273: 0 0 1600400502 0 0 0 0 0 PCI-MSI-edge eth0 1274: 0 0 0 0 0 0 0 0 PCI-MSI-edge ahci NMI: 0 0 0 0 0 0 0 0 Non-maskable interrupts LOC: 214252181 69439018 317298553 21943690 72562482 56448835 137923978 407514738 Local timer interrupts RES: 27516446 16935944 26430972 44957009 24935543 19881887 57746906 24298747 Rescheduling interrupts CAL: 10655 10705 10685 10567 10689 10669 10667 396 function call interrupts TLB: 529548 462587 801138 596193 922202 747313 2027966 946594 TLB shootdowns TRM: 0 0 0 0 0 0 0 0 Thermal event interrupts THR: 0 0 0 0 0 0 0 0 Threshold APIC interrupts SPU: 0 0 0 0 0 0 0 0 Spurious interrupts ERR: 0 All the values seems more or less the same for all the cores but this one IO-APIC-fasteoi 3w-9xxx, uhci_hcd:usb1 only affects to the core 7 (the same with the wait time of 40% ~ 60%) could be something attached to the usb port causing the issue? Thanks in advanced

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >