  • Mirth: Transforming a response message in a separate Channel and returning it to original channel

    - by Ryan H
    I have a channel that takes HL7v2 message and converts it to HL7v3. It invokes a SOAP web service and receives a response in HL7v3. I need to convert that response back to HL7v2. Currently: I "Send Response to:" my second channel. That can convert it fine back to HL7v2, but it doesn't seem to return a response message. I want that second transformation to be the response to the initiator which is an LLP Listener.

    Read the article

  • What is the benefit of triple buffering?

    - by user782220
    I read everything written in a previous question. From what I understand in double buffering the program must wait until the finished drawing is copied or swapped before starting the next drawing. In triple buffering the program has two back buffers and can immediately start drawing in the one that is not involved in such copying. But with triple buffering if you're in a situation where you can take advantage of the third buffer doesn't that suggest that you are drawing frames faster than the monitor can refresh. So then you don't actually get a higher frame rate. So what is the benefit of triple buffering then?

    Read the article

  • Channel Revenue Management and General Ledger Integration

    - by LuciaC-Oracle
    Back in February of this year, we told you about the EBS Business Process Advisor: CRM Channel Revenue Management document which has detailed information about the Channel Revenue Management application business flow and explains integration points with other applications.  But we thought that you might like to have even more information on exactly how Channel Revenue Management passes data to General Ledger. Take a look at Integration Troubleshooting: Oracle Channel Revenue Management to GL via Subledger Accounting (Doc ID 1604094.2).  This note includes comprehensive information about the data flow between Channel Revenue Management and GL, offers troubleshooting tips and explains some key setups. Let us know what you think - start a discussion in the My Oracle Support Channel Revenue Management Community!

    Read the article

  • Best triple head display setup

    - by dgel
    I'm currently running Ubuntu 12.04 with a darn good triple head display setup. I've got a VisionTek 900530 Radeon HD 5450 512MB DDR3 PCI Express video card that has two DVI outputs and one Mini DisplayPort that I have connected to a HDMI adapter. I'm running three identical Asus 1920x1080 monitors that each have a DVI, VGA, and HDMI input. I'm using the xorg-edgers ppa, so I'm using the open source radeon driver version 6.99.99. I tried using the ATI binary fglrx driver, but I wasn't able to get the three monitors working properly- the monitor connected via HDMI / DisplayPort wouldn't run at full resolution. The setup is almost perfect: Compiz runs fine and is quite snappy. I'm not able to use that great compiz feature where you can drag a window to the side of a display and it will half maximize. I occasionally experience display corruption weirdness with Unity and need to restart it. When I use a dropdown menu in LibreOffice it often pops the menu down in another window. For example, if I'm using the center monitor and click the Insert menu, the menu pulls down on the monitor to my right, forcing me to chase it. If I chase down the menu and choose Manual Break, the dialog appears over on my left monitor. This absurdity is mildly entertaining but has lost its novelty. I've decided to build a new system and have spared no expense- latest i7 processor, SSD, etc. I really like the performance of the Nvidia binary drivers, so I put two ZOTAC ZT-40707-10L GeForce GT 440 in the system, figuring I'd have four DVI outputs and an awesome triple (or even eventually quad) head setup. Unfortunately it appears that I didn't do sufficient research before my purchase. It seems that Nvidia TwinView only supports two monitors on one card (I guess that's why they call it TwinView...). I messed around with running two X servers, but I really don't want that- being able to drag windows to any monitor is critical. It doesn't sound like Xinerama is an option because from what I understand it simply doesn't support Compiz. I've seen a BaseMosaic option that can be used with the Nvidia drivers that appears to support an almost unlimited number of heads- unfortunately me cheap little cards don't support it. I'm also not sure whether you'll still have all nice maximizing and snapping that TwinView provides, or whether Ubuntu will only see it as one massive display. I put my old trusty ATI card into my new system and installed 12.10. I'm using the opensource radeon drivers again because even in 12.10 I can't get the fglrx binary drivers to do triple head. Unfortunately, even with an unbelievably powerful system the experience is extremely sluggish (much more so than my experience in 12.04). The menu scattering problem appears to be fixed, but I get a lot of nasty Unity display corruption. So finally, my question is this: What hardware / drivers should I use? I'm willing to buy (almost) any video card(s). I have two PCI-Express 3.0 slots on my motherboard (which has an integrated Intel HD card). I'm willing to use ATI or Nvidia cards and willing to run Ubuntu 12.04.1 or 12.10. I'm not a gamer, but do want beautiful and snappy Compiz effects. Does anyone out there have the perfect triple head setup in 12.04 or 12.10? What hardware / drivers are you using? I have those two Nvidia cards but will probably be returning them unless someone knows a way to use them together for a triple head setup. Since I'm having pretty good luck with a single ATI card providing three displays, should I just buy a beefier one with the hopes that it will fix the horrible sluggishness I'm experiencing in 12.10?

    Read the article

  • configuring a Fibre Channel switch

    - by lindenb
    Hi all, (I'm asking this for a friend and I'm don't know most of this technical stuff, so I'm sorry in advance if I'm not clear enough to describe the problem) Where can i find any information about how to configure a Fibre Channel switch ( QLocic , Mini GBic, QME2572 ) to make it communicate with a Dell R905 and a Dell M905 Blade Server ? Many thanks in advance Pierre

    Read the article

  • Concepts: Channel vs. Stream

    - by hotzen
    Hello, is there a conceptual difference between the terms "Channel" and "Stream"? Do the terms require/determine, for example, the allowed number of concurrent Consumers or Producers? I'm currently developing a Channel/Stream of DataFlowVariables, which may be written by one producer and read by one consumer as the implementation is destructive/mutable. Would this be a Channel or Stream, is there any difference at all? Thanks

    Read the article

  • Unable to start GRUB2 on Triple boot Macbook Pro with OS X Lion, Windows 7 and Ubuntu

    - by Shravan
    I installed Windows 7 using Bootcamp. Then I created a partition from the empty space in the Windows partition and another 4GB partition for the linux swap using GParted. I installed Ubuntu 12.04 LTS in the the newly created partition from the Windows partition. Now GRUB2 does not load and I can only see the blinking cursor on the top right when selecting "Windows HD" from the 'option' key at the start up. OS X works fine but nothing else. Could someone please help me fix this? I am attaching the boot-info from the boot-repair tool. http://paste.ubuntu.com/1040169/

    Read the article

  • Cisco ASA bonding/teaming/port-channel capabilities

    - by Antoine Benkemoun
    Hello, This seemed to me like a really simple question that I would be able to answer by myself but I have not been able to find any info on this subject. I have a Cisco ASA 5510 which has 4 FastEthernet interfaces. I was wondering if it would be possible to use 2 or 3 of these interfaces as a port-channel in order to agregate bandwidth for multiple VLANs. I have found no info on the Cisco website nor on Google. Is this just a stupid/crazy idea or am I missing something ? Thank you in advance for your help, Antoine

    Read the article

  • Restart Fibre channel controller after blade bootup IBM HS bladecentre

    - by Spence
    I have a remote system that needs to resume on startup. If the system is simply powered on then the blades boot before the SAN is online and then the only thing you can do is restart the systems. Is it possible to restart the fibre channel controller? That way I could have a system restart the controller after boot, connect to the SAN and then restart all servers requiring SAN information? Please note that I'm not a sys admin, just shooting for ideas to get a clean startup to work, apologies if my terminology is wrong.

    Read the article

  • Virtual fiber channel HBA in Solaris

    - by Phil
    We are trying to set up some virtual Fibre Channel HBA's in Solaris. This seems to be possible with NPIV. Creating NPIV's in a Solaris global zone works fine, but passing that NPIV to a zone didn't work at all. We tried to pass the NPIV as following: # zonecfg -z zone1 'info' zonename: studentz1 [...] device: match: /devices/pci@0,0/pci8086,25f9@6/pci8086,350c@0,3/pci1077,140@4/fp@1,0:devctl allow-partition not specified allow-raw-io not specified Wat we want to do is, set up an environment for SAN exercises. We don't have a physical host per student, so we try to virtualise that in some way (Solaris zones or VMware). It should be possible to display the WWN of the virtual HBA and mount the storage presented by the disk subsystem. Any ideas to pass the NPIV to a solaris zone or to virtualise this with vmware?

    Read the article

  • Solaris Fibre Channel target - Configure QLogic QLA2340

    - by growse
    I'm currently trying to set up a small storage system as a fibre channel target. This is for testing, so I'm currently using Solaris (Nexenta) and a QLogic QLA2340 HBA. For some reason, the qlc and qlt drivers don't support the QLA2340, so I'm using the qla2300 driver from QLogic's website. I've also got the scli utility installed for configuration. The HBA is detected by the system. That said, it's not clear how I get from this point to a point where I have a ZFS volume being exposed as an FC target. I was originally following this guide (http://www.youtube.com/watch?v=yzEBd3l7Qn4) but it seems that without the qlc/qlt drivers, Sun's configuration tools won't work. Does that also imply that COMSTAR also won't work? What's the best way to expose an FC target with this setup? Most of the options I'm seeing in scli complain that the port state is LinkDown (it is, I've not plugged anything in yet). Do I have to have my FC client plugged up and working before I can configure the target? Apologies for the slight vagueness of the question, but I'm not overly familiar with the terminology.

    Read the article

  • Quad channel memory and compatibility

    - by balteo
    My motherboard has quad channel memory compatibility. There are 8 memory slots in all: 4 slots are black the other 4 slots are white. I currently have 4 memory modules of 1 GB each in the 4 white slots. That leaves me with 4 free memory slots. My question is: can I put 4 memory modules of 2 GB each in the 4 remaining slots or do I have to use modules of 1 GB all over? FYI here is the output of lshw: alpha description: Ordinateur Tour produit: Precision WorkStation 690 *-cpu:0 description: CPU produit: Intel(R) Xeon(R) CPU X5355 @ 2.66GHz *-memory description: Mémoire Système identifiant matériel: 1000 emplacement: Carte mère taille: 4GiB *-bank:0 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) produit: HYMP512F72CP8N3-Y5 fabriquant: Hynix Semiconductor (Hyundai Electronics) identifiant matériel: 0 numéro de série: 56737501 emplacement: DIMM 1 taille: 1GiB bits: 64 bits horloge: 667MHz (1.5ns) *-bank:1 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) produit: HYMP512F72CP8N3-Y5 fabriquant: Hynix Semiconductor (Hyundai Electronics) identifiant matériel: 1 numéro de série: 48115124 emplacement: DIMM 2 taille: 1GiB bits: 64 bits horloge: 667MHz (1.5ns) *-bank:2 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) produit: HYMP512F72CP8N3-Y5 fabriquant: Hynix Semiconductor (Hyundai Electronics) identifiant matériel: 2 numéro de série: 48115523 emplacement: DIMM 3 taille: 1GiB bits: 64 bits horloge: 667MHz (1.5ns) *-bank:3 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) produit: HYMP512F72CP8N3-Y5 fabriquant: Hynix Semiconductor (Hyundai Electronics) identifiant matériel: 3 numéro de série: 48115424 emplacement: DIMM 4 taille: 1GiB bits: 64 bits horloge: 667MHz (1.5ns) *-bank:4 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) [vide] fabriquant: FFFFFFFFFFFF identifiant matériel: 4 numéro de série: FFFFFFFF emplacement: DIMM 5 bits: 64 bits horloge: 667MHz (1.5ns) *-bank:5 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) [vide] fabriquant: FFFFFFFFFFFF identifiant matériel: 5 numéro de série: FFFFFFFF emplacement: DIMM 6 bits: 64 bits horloge: 667MHz (1.5ns) *-bank:6 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) [vide] fabriquant: FFFFFFFFFFFF identifiant matériel: 6 numéro de série: FFFFFFFF emplacement: DIMM 7 bits: 64 bits horloge: 667MHz (1.5ns) *-bank:7 description: FB-DIMM DDR2 FB-DIMM Synchrone 667 MHz (1,5 ns) [vide] fabriquant: FFFFFFFFFFFF identifiant matériel: 7 numéro de série: FFFFFFFF emplacement: DIMM 8 bits: 64 bits horloge: 667MHz (1.5ns) *-pci:0 description: Host bridge produit: 5000X Chipset Memory Controller Hub fabriquant: Intel Corporation identifiant matériel: 100 information bus: pci@0000:00:00.0 version: 12 bits: 32 bits horloge: 33MHz

    Read the article

  • WWNs,WWPNs and Fibre Channel addresses

    - by user238230
    Lots of contradictory on these subjects and I don't know why. My first question is about the 64 bit WWN. One reference claims the terms WWN and WWPN are synonymous. An online source seems to refute this. They say: A WWPN (world wide port name) is the unique identifier for a fibre channel port where a WWN (world wide name) the unique identifier for the node itself. A good example is a dual port HBA. There will be two WWPN's (one for each port) and only a single WWN for the card itself. Question #1: Which is correct? I’m almost positive I read that every “Port” has a WWN. My next question is about the 24 bit FC address that is dynamically allocated to a port when it is introduced to the switch. The Domain ID field is defined as: "a unique number provided to each switch in the fabric." Question #2: Do Domain IDs only apply to switch ports? For example what would the Domain ID be for a HBA? None? The same as the switch port it is connected to? Question #3: My last question is about the Name Server of a switch. A book example shows the routing of a message through the switch. It uses the WWNs of the source and destination ports to route the message. I am assuming that the Name Server must associate the WWN and the FC address in some way in order to route the message, correct?

    Read the article

  • Windows 7/Ubuntu 10.10 Dual-Triple Boot Partitioning Recommendation for HP Laptop OEM

    - by Denja
    Hi Linux Community, I find my self struggling with the ever slow and buggy windows OS once again. It's Time for me to go with the Ubuntu/Linux way for a better and faster Operating System. As a Computer technician i want to learn and use both Systems but possibly introduce New users to more affordable Linux Based Systems. For now, Im in the process of creating dual-boot or even triple boot layouts on my laptop machine Here's the layout in use now: * (C:) Windows 7 system partition NTFS - 284,89GB (Primary,Boot,Pagefile,Dump) * HP_TOOLS system partition FAT32 - 99MB (Primary) * (D:) RECOVERY partition NTFS - 12,90GB (Primary) * SYSTEM partition NTFS 199MB (Primary) Here's the layout I want to make. * (C:) Windows 7 system partition NTFS - 60GB (Primary) (sda1) * (D:) Windows data partition (user files) NTFS - 60GB(Extended or Primary)(sda2);wanna share with Linux * Linux root Ext4 - 10GB (Primary)(sda3) * Linux swap swap- RAM size, 3GB (sda4) * Linux home Ext4- 164,9GB (Extended)(sda5) Question 1: Based on my layout what is your suggestion for a Triple Boot layout for an additional Linux OS (Like Puppy)? Thank you in advance for your advises and suggestions.

    Read the article

  • Understanding When Social Interactions Should Be Resolved in Another Channel

    - by Christina McKeon
    Guest Blogger: Aphrodite Brinsmead, Senior Analyst at Ovum Agents need to respond to customers’ social comments and questions quickly and in the right tone. But more importantly, they need to offer resolutions. Customers care most about how long it takes to find information rather than which channel they are using. They choose to use social media because they are comfortable with the channel and it offers a convenient way to communicate. Ideally agents will resolve questions within social media, but they need guidance as to how and when to escalate interactions to a more private channel. First, businesses should assess the way in which customers are using social media to communicate with them and categorize posts into groups: complaints, feedback, technical queries or more general support questions. They should then consider the types of interactions that can easily be handled within social media and those that need to be followed up in another channel. This will be very dependent on the industry. Examples of queries that can be resolved in social media include Shipping pricing and timeframes Outage updates and resolution plans Flight status information Product stock check Technical support videos or forum posts Availability of facilities Both customers and agents need to be educated about the types of questions they can expect to resolve within social media. As the channel matures as a customer service tool, it needs to have value other than just as a forum for complaints. Social customer service agents need the power to start a web chat or phone call Any questions where customers need to divulge personal details in order to get a resolution will need to be addressed in a private channel: a private social message, web chat, email or phone call. Customers should never disclose their date of birth, social security, credit card number, or healthcare records in a public forum. Flight issues, changes to a booking, billing queries or account updates will all need to be completed via a private interaction. Agents responding to questions on social media need the ability to start a web chat or phone call with the customer. The customer doesn’t want to have to repeat their question and the agent should be empowered to connect customer records and access account or billing information. These agents will need to be trained across different channels and should be able to view all customer communications in one application. They also need to follow up questions that began on a public forum in the initial channel to make it clear that the issue was addressed. In order to make this possible, social media needs to be integrated as part of a broader customer service strategy. Irrespective of how many channels are used to complete an interaction, businesses should prioritize customer satisfaction and issue resolution. They need a clear strategy and trained agents that can handle and respond to social interactions. Follow me on Twitter @diteb. 

    Read the article

  • My Dog, Cross-Channel Shopping, and Fusion SCM

    - by Kathryn Perry
    A guest post by Mark Carson, Director, Oracle Fusion Supply Chain Management I was walking my dog Max in an open space behind my house. As we tromped through the tall weeds I remembered it is tick season and that I should get Max some protection. While he sniffed merrily in the tick infested brush, I started shopping in the middle of an open field on my phone. I thought it would be convenient to pick up the tick medicine from a pet store on the way home. Searching the pet store website I saw that they had the medicine, but there was no information on whether the store had any in stock and there were no options for shipping it to the store for pickup. I could return it, but not pick it up which seamed kind of odd. I really didn't feel like making calls to the local stores to find out if they had it. Since the product is popular, I tried one of the large 'everything' stores. Browsing its website I could see that it could be shipped to me, shipped to the store for free, and that the store nearest to me had it in stock. Needless to say, this store became a better option. This experience is a small example of why retailers, distributors, and manufactures have placed a high priority on enabling 'cross-channel commerce.' Shoppers like you and me expect to be able to search, compare, buy and return products on-line and over the phone using a variety of devices including PDAs, tablets and in-store kiosks. The pet store lost my business because its web channel had limited information about its stores. I have spoken with many customers and prospects about cross-channel commerce. They all realize the business implications and urgency behind cross-channel commerce but recognize there are challenges to enable it. New and existing applications must be integrated together globally through a consistent cross-channel business process. Integration is required between applications that provide the initial shopping experience and delivery applications associated with warehouses, stores, and partners. The enablement must be accomplished in a flexible way to react to fast-changing product portfolios and new acquisitions, while at the same time minimizing costs through reuse of existing systems. Meanwhile, the business must continue to grow and decision makers need to balance new capability with peak seasons. The challenges above are not unique to retail. Any customer in any industry who has multiple points for capturing orders and multiple points for fulfilling orders will face these challenges. With this in mind, we had a unique opportunity in Fusion SCM to re-think how to build a set of modular and flexible applications in the order management space that would make these challenges easier to conquer. The results are Fusion Distributed Order Orchestration and Global Order Promising. These applications can help companies, such as the pet store, enable true cross-channel commerce. The apps provide highly adaptable and flexible business processes to automate order orchestration across multiple cross-channel systems. They also show a global view of supply across warehouses, stores, and partners for real-time availability and more accurate order promising. Additional capability includes a standards-based integration framework for seamless execution and the ability to reuse existing systems for faster and lower cost implementations. OK, that was a mouthful of features and benefits. As Max waited to cross the street (he can do basic math too), I wondered if he could relate. He does not care about leash laws, pick-up courtesy, where he can/can't walk, what time of day it is, or even ticks. He does not care about how all these things could make walking complicated. He just wants to walk. Similarly, customers just want to shop and companies just want to make it easier to sell and deliver. You can learn more about Distributed Order Orchestration and Global Order Promising in cross-channel here.

    Read the article

  • Jenkins slave jobs failing on "Unexpected termination of channel"

    - by Clark Wright
    I am currently seeing a set of errors across my builds. Is this expected behaviour if you loose Jenkins (say to a box crash, or a kill -9)? Or is there something worse going on (like a bad network connection)? The stack and error is: FATAL: hudson.remoting.RequestAbortedException: java.io.IOException: Unexpected termination of the channel hudson.remoting.RequestAbortedException: hudson.remoting.RequestAbortedException: java.io.IOException: Unexpected termination of the channel at hudson.remoting.Request.call(Request.java:149) at hudson.remoting.Channel.call(Channel.java:681) at hudson.remoting.RemoteInvocationHandler.invoke(RemoteInvocationHandler.java:158) at $Proxy175.join(Unknown Source) at hudson.Launcher$RemoteLauncher$ProcImpl.join(Launcher.java:861) at hudson.Launcher$ProcStarter.join(Launcher.java:345) at hudson.tasks.CommandInterpreter.perform(CommandInterpreter.java:82) at hudson.tasks.CommandInterpreter.perform(CommandInterpreter.java:58) at hudson.tasks.BuildStepMonitor$1.perform(BuildStepMonitor.java:19) at hudson.model.AbstractBuild$AbstractRunner.perform(AbstractBuild.java:703) at hudson.model.Build$RunnerImpl.build(Build.java:178) at hudson.model.Build$RunnerImpl.doRun(Build.java:139) at hudson.model.AbstractBuild$AbstractRunner.run(AbstractBuild.java:473) at hudson.model.Run.run(Run.java:1410) at hudson.model.FreeStyleBuild.run(FreeStyleBuild.java:46) at hudson.model.ResourceController.execute(ResourceController.java:88) at hudson.model.Executor.run(Executor.java:238) Caused by: hudson.remoting.RequestAbortedException: java.io.IOException: Unexpected termination of the channel at hudson.remoting.Request.abort(Request.java:273) at hudson.remoting.Channel.terminate(Channel.java:732) at hudson.remoting.Channel$ReaderThread.run(Channel.java:1157) Caused by: java.io.IOException: Unexpected termination of the channel at hudson.remoting.Channel$ReaderThread.run(Channel.java:1133) Caused by: java.io.EOFException at java.io.ObjectInputStream$BlockDataInputStream.peekByte(ObjectInputStream.java:2554) at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1297) at java.io.ObjectInputStream.readObject(ObjectInputStream.java:351) at hudson.remoting.Channel$ReaderThread.run(Channel.java:1127)

    Read the article

  • Fiber Channel Loop vs Point to Point

    - by RandomInsano
    So, I'm playing with a couple of QLogic QLA2340s connected directly together. I've got options here to either have them act as a loop, or in point to point mode. What's the difference if I'm only going to have two machines connected together? Is point-to-point more efficient? The firmware has an option to prefer loop, then fall back to p2p. Anyone have any idea if there are performance benefits or drawbacks? It's pretty hard to find that information.

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

  • Does DirectX implement Triple Buffering?

    - by Asik
    As AnandTech put it best in this 2009 article: In render ahead, frames cannot be dropped. This means that when the queue is full, what is displayed can have a lot more lag. Microsoft doesn't implement triple buffering in DirectX, they implement render ahead (from 0 to 8 frames with 3 being the default). The major difference in the technique we've described here is the ability to drop frames when they are outdated. Render ahead forces older frames to be displayed. Queues can help smoothness and stuttering as a few really quick frames followed by a slow frame end up being evened out and spread over more frames. But the price you pay is in lag (the more frames in the queue, the longer it takes to empty the queue and the older the frames are that are displayed). As I understand it, DirectX "Swap Chain" is merely a render ahead queue, i.e. buffers cannot be dropped; the longer the chain, the greater the input latency. At the same time, I find it hard to believe that the most widely used graphics API would not implement such fundamental functionality correctly. Is there a way to get proper triple buffered vertical synchronisation in DirectX?

    Read the article

  • Concurrent WCF calls via shared channel

    - by Kent Boogaart
    I have a web tier that forwards calls onto an application tier. The web tier uses a shared, cached channel to do so. The application tier services in question are stateless and have concurrency enabled. But they are not being called concurrently. If I alter the web tier to create a new channel on every call, then I do get concurrent calls onto the application tier. But I wanted to avoid that cost since it is functionally unnecessary for my scenario. I have no session state, and nor do I need to re-authenticate the caller each time. I understand that the creation of the channel factory is far more expensive than than the creation of the channels, but it is still a cost I'd like to avoid if possible. I found this article on MSDN that states: While channels and clients created by the channels are thread-safe, they might not support writing more than one message to the wire concurrently. If you are sending large messages, particularly if streaming, the send operation might block waiting for another send to complete. Firstly, I'm not sending large messages (just a lot of small ones since I'm doing load testing) but am still seeing the blocking behavior. Secondly, this is rather open-ended and unhelpful documentation. It says they "might not" support writing more than one message but doesn't explain the scenarios under which they would support concurrent messages. Can anyone shed some light on this?

    Read the article

  • Creating blur with an alpha channel, incorrect inclusion of black

    - by edA-qa mort-ora-y
    I'm trying to do a blur on a texture with an alpha channel. Using a typical approach (two-pass, gaussian weighting) I end up with a very dark blur. The reason is because the blurring does not properly account for the alpha channel. It happily blurs in the invisible part of the image, whcih happens to be black, and thus results in a very dark blur. Is there a technique to blur that properly accounts for the alpha channel?

    Read the article

  • OSB 11g & SAP – Single Channel/Program ID for Multiple IDOCs

    - by Shub Lahiri, A-Team
    Background This note is a supplement to the blog entry, SOA 11g & SAP – Single Channel/Program ID for Multiple IDOCs by Greg Mally. Greg has shown how a single SOA Suite composite can be used with iWay Adapters to receive multiple IDOC types via a single channel in the adapter, corresponding to a single programID on the SAP system. We will try to address the same requirements within the OSB framework here. Project Built - Design Time The basic build of an OSB project with iWay SAP Adapter, as seen in another entry in this blog, consists of working in OSB Design console and Application Explorer. OSB Design Time - Part 1 We will create a placeholder project first in OSB with a proper directory structure, so that we can export the WSDL, XSD and the JCA binding information from Application Explorer directly into this project. Application Explorer - iWay Design Time Tool Receiving IDOCs is classified as an inbound event within Application Explorer. For setting up events, a channel is first defined (e.g. iDoc_Channel) using the same PROGRAMID (RFC destination), as defined within SAP for the OSB server. Next, the same channel is used to export the JCA Inbound Event artifacts for the candidate IDOC, e.g. DEBMAS06 directly to the pre-created OSB project. Note that the validation for schema has been turned off. As a result, this will allow the adapter, at runtime, to use a single channel to receive multiple IDOC types from SAP and pass them on to the OSB runtime engine without any validation. In other words, we do not have to repeat the above step for each IDOC type. OSB Design Time - Part 2 Create 2 simple XML based Business Services to write to a file, e.g.  SAP_DEBMAS_File and SAP_MATMAS_File. Next, generate a Proxy Service using the JCA binding file exported from Application Explorer in the previous section. In the generated proxy service, edit the message flow and add a route node. Add a routing table in the route node with the following routing function. fn:local-name-from-QName(fn:node-name($body/*[1])) This function takes advantage of the fact that the XML payload at runtime, after translation by adapter, has the IDOC type as the top element. With the routing function in place, build the routing table to add 2 branches to route the IDOCs to the appropriate Business Service for writing the XML payload to files in separate directories. This completes the build of the OSB project. Testing - Run-Time After deployment and activation, the SAP adapter will wait to receive multiple types of IDOCs sent from the SAP system using a single channel. Upon receipt of the IDOCs, the OSB project will route them appropriately to save the corresponding XML payloads for different IDOC types in different directories.

    Read the article

  • Sound Channel map incorrect on an ION 330 ASRock

    - by math
    I have a ION 330 ASRock just updated on Precise and the sound channel mapping is incorrect. Channel map is set as follow: Front Left = Front left Center = Rear Left Front Right = Font Right Rear Right = LFE Rear Left = Center LFE = Rear Right I am testing the sound channel using speaker-test -c 2 -t wav Can some one tell me how I can remap easily? I have tried several possible changes to /etc/pulse/defaut.pa unsuccessfully.

    Read the article

  • How to change the volume of left channel using pulseaudio

    - by user2622247
    I am recording the video using logitech camera and bluetooth microphone. Logitech can used for recording both audio and video. When I turn on bluetooth microphone in the middle of recording, it is replacing the logitech audio channel due to this we are getting the bluetooth audio from the left channel. But when I turn off the bluetooth then I get the logitech audio on left channel but the volume is very low and also getting the some noise. I am using PulseAudio and ffmpeg for recording purpose. So how can I increase / change the volume of left channel during runtime?