Search Results

Search found 9492 results on 380 pages for 'logic unit'.

Page 204/380 | < Previous Page | 200 201 202 203 204 205 206 207 208 209 210 211  | Next Page >

  • Astar implementation in AS3

    - by Bryan Hare
    Hey, I am putting together a project for a class that requires me to put AI in a top down Tactical Strategy game in Flash AS3. I decided that I would use a node based path finding approach because the game is based on a circular movement scheme. When a player moves a unit he essentially draws a series of line segments that connect that a player unit will follow along. I am trying to put together a similar operation for the AI units in our game by creating a list of nodes to traverse to a target node. Hence my use of Astar (the resulting path can be used to create this line). Here is my Algorithm function findShortestPath (startN:node, goalN:node) { var openSet:Array = new Array(); var closedSet:Array = new Array(); var pathFound:Boolean = false; startN.g_score = 0; startN.h_score = distFunction(startN,goalN); startN.f_score = startN.h_score; startN.fromNode = null; openSet.push (startN); var i:int = 0 for(i= 0; i< nodeArray.length; i++) { for(var j:int =0; j<nodeArray[0].length; j++) { if(!nodeArray[i][j].isPathable) { closedSet.push(nodeArray[i][j]); } } } while (openSet.length != 0) { var cNode:node = openSet.shift(); if (cNode == goalN) { resolvePath (cNode); return true; } closedSet.push (cNode); for (i= 0; i < cNode.dirArray.length; i++) { var neighborNode:node = cNode.nodeArray[cNode.dirArray[i]]; if (!(closedSet.indexOf(neighborNode) == -1)) { continue; } neighborNode.fromNode = cNode; var tenativeg_score:Number = cNode.gscore + distFunction(neighborNode.fromNode,neighborNode); if (openSet.indexOf(neighborNode) == -1) { neighborNode.g_score = neighborNode.fromNode.g_score + distFunction(neighborNode,cNode); if (cNode.dirArray[i] >= 4) { neighborNode.g_score -= 4; } neighborNode.h_score=distFunction(neighborNode,goalN); neighborNode.f_score=neighborNode.g_score+neighborNode.h_score; insertIntoPQ (neighborNode, openSet); //trace(" F Score of neighbor: " + neighborNode.f_score + " H score of Neighbor: " + neighborNode.h_score + " G_score or neighbor: " +neighborNode.g_score); } else if (tenativeg_score <= neighborNode.g_score) { neighborNode.fromNode=cNode; neighborNode.g_score=cNode.g_score+distFunction(neighborNode,cNode); if (cNode.dirArray[i]>=4) { neighborNode.g_score-=4; } neighborNode.f_score=neighborNode.g_score+neighborNode.h_score; openSet.splice (openSet.indexOf(neighborNode),1); //trace(" F Score of neighbor: " + neighborNode.f_score + " H score of Neighbor: " + neighborNode.h_score + " G_score or neighbor: " +neighborNode.g_score); insertIntoPQ (neighborNode, openSet); } } } trace ("fail"); return false; } Right now this function creates paths that are often not optimal or wholly inaccurate given the target and this generally happens when I have nodes that are not path able, and I am not quite sure what I am doing wrong right now. If someone could help me correct this I would appreciate it greatly. Some Notes My OpenSet is essentially a Priority Queue, so thats how I sort my nodes by cost. Here is that function function insertIntoPQ (iNode:node, pq:Array) { var inserted:Boolean=true; var iterater:int=0; while (inserted) { if (iterater==pq.length) { pq.push (iNode); inserted=false; } else if (pq[iterater].f_score >= iNode.f_score) { pq.splice (iterater,0,iNode); inserted=false; } ++iterater; } } Thanks!

    Read the article

  • Find BIOS update for HP Pavilion xt966

    - by NitroxDM
    I installed FreeNAS on a HP Pavilion xt966. Every three seconds or so I message comes up on the console. acpi_tz0: _TMP value is absurd, ignored (-270.2C) From what I have been able to find this is because of a bug in the BIOS... but I have yet to find an update for it. HP's site only shows drivers. FreeNAS is build on BSD. Anyone know where to find a BIOS update for this unit?

    Read the article

  • When a python process is killed on OSX, why doesn't it kill the child processes?

    - by Hugh
    I found myself getting very confused a while back by some changes that I found when moving Python scripts from Linux over to OSX... On Linux, if a python script has called os.system(), and the calling process is killed, the called process will be killed at the same time. On OSX, however, if the main process is killed, anything that it launched is left behind. Is there something somewhere in OSX/Python where I can change this behaviour? This is causing problems on our render farm, where the processes can be killed from the management GUI, but the top level process is really just a wrapper, so, while the render farm management might think that the process has gone and the machine is freed up for another task, the actual processor-intensive task is still running, which can lead to huge blockages. I know that I could write more logic to catch the kill signal and pass it on to the child processes, but I was hoping that it might be something that could be enabled at a lower level.

    Read the article

  • Systemctl hangs trying to start MySQL on Fedora

    - by Cerin
    When I try to start Mysql on Fedora via systemctl start mysqld.service, it hangs indefinitely and never starts. Running mysqld_safe --skip-grant-tables & or mysqld_safe --nowatch --basedir=/usr starts the server just fine, indicating the database is still there, but using service or systemctl doesn't work at all. Nothing is shown in /var/log/mysqld.log. However, `/var/log/messages shows thousands of messages like: Oct 29 15:55:52 myserver systemd[1]: mysqld.service holdoff time over, scheduling restart. Oct 29 15:55:52 myserver systemd[1]: Job pending for unit, delaying automatic restart. How do I diagnose what's wrong and get MySQL to start?

    Read the article

  • D-Link DNS-323 NAS firmware update

    - by Mark Beaton
    Hi all, I've got a D-Link DNS-323 NAS enclosure holding a bunch of multimedia files that I've (possibly stupidly) just updated the firmware on, from 1.03 to 1.08. The updater indicated it applied the firmware patch successfully, but after rebooting it I can no longer get into it via the web interface, either via the static IP I had assigned it before the update, or by any of the DHCP-assigned addresses that I can see are currently assigned by my router. The unit just sits there, with the drives (2x512 set up as RAID-1) thrashing away seemingly forever... So, my question - has anyone had a similar experience with one of these units? Any advice etc? I've googled the hell out of it, and can't find anything useful.

    Read the article

  • How to get two seperate remote domain controllers with same IP to work?

    - by Mr. Mister
    Hi, I have a VPN setup between multiple locations. Between each location and the central point (me), is a trust between our domain controllers. It all works great.. A new location wants to join, but their AD controller is using an IP address that is already in use by another AD in a separate location. Neither locations can change their IP addresses, but apparently there is a NAT rule that could be used to allow communication between each AD controller? The central site has a Cisco 5510 firewall which could perform the NAT, but I am unsure of the logic behind the NAT rule. Is anyone able to explain or help out? Thanks.

    Read the article

  • upgrading my computer system for office use

    - by denise ellul
    Presently I have the under-mentioned computer system. What should be changed and upgraded with the following products that I own presently? I am interested in performance issues related to cache memory, bus speed, RAM, CAS latency as well as other considerations. Thanks for your help. Processor (CPU): Intel Celeron Dual Core E3300 2.5 GHz Motherboard: Asus P5QPL-AM G41 Main Memory (RAM): 2 GB Team Elite DDR2 PC8000 Case: Coolermaster RC330 Power Supply Unit: 500W EZ-Cool Standard Storage Device (Hard Drive): 500GB Samsung Video Card: Intel GMA X4500 (On-board) Optical Drive: LG GH22NS50 Sound Card: AC 97 (On – board) Card Reader: Akasa Black TFT Monitor: 19” View Sonic Speakers: Logitech S120 2.0

    Read the article

  • Can I make ssh tell me which control file it would use for multiplexing?

    - by Ryan Thompson
    I am using the following options in my ~/.ssh/config in order to enable connection multiplexing: ControlMaster auto ControlPath ~/.ssh/control/master-%r@%h:%p However, this has the annoying problem that the first shell to connect to a particular server must be the last to disconnect, because it is the master connection that all the other connections are using. So if you log out of the master, it appears to just hang. To solve this, I would like to wrap ssh with a script that checks if the control master file exists, and if not, starts a master ssh process in the background. Then it would start a slave ssh session. In order to accomplish this, my script would have to determine the path to the control file that ssh would use. This would entail parsing the ssh command line options and config files and implementing the logic for determining the ControlPath. Is there any way to just ask ssh what path it would use, so I can check it?

    Read the article

  • Multi-threaded .NET application blocks during file I/O when protected by Themida

    - by Erik Jensen
    As the title says I have a .NET application that is the GUI which uses multiple threads to perform separate file I/O and notice that the threads occasionally block when the application is protected by Themida. One thread is devoted to reading from serial COM port and another thread is devoted to copying files. What I experience is occasionally when the file copy thread encounters a network delay, it will block the other thread that is reading from the serial port. In addition to slow network (which can be transient), I can cause the problem to happen more frequently by making a PathFileExists call to a bad path e.g. PathFileExists("\\\\BadPath\\file.txt"); The COM port reading function will block during the call to ReadFile. This only happens when the application is protected by Themida. I have tried under WinXP, Win7, and Server 2012. In a streamlined test project, if I replace the .NET application with a MFC unmanaged application and still utilize the same threads I see no issue even when protected with Themida. I have contacted Oreans support and here is their response: The way that a .NET application is protected is very different from a native application. To protect a .NET application, we need to hook most of the file access APIs in order to "cheat" the .NET Framework that the application is protected. I guess that those special hooks (on CreateFile, ReadFile...) are delaying a bit the execution in your application and the problem appears. We did a test making those hooks as light as possible (with minimum code on them) but the problem still appeared in your application. The rest of software protectors that we tried (like Enigma, Molebox...) also use a similar hooking approach as it's the only way to make the .NET packed file to work. If those hooks are not present, the .NET Framework will abort execution as it will see that the original file was tampered (due to all Microsoft checks on .NET files) Those hooks are not present in a native application, that's why it should be working fine on your native application. Oreans support tried other software protectors such as Enigma Protector, Engima VirtualBox, and Molebox and all exhibit the exact same problem. What I have found as a work around is to separate out the file copy logic (where the file exists call is being made) to be performed in a completely separate process. I have experimented with converting the thread functions from unmanaged C++ to VB.NET equivalents (PathFileExists - System.IO.File.Exists and CreateFile/ReadFile - System.IO.Ports.SerialPort.Open/Read) and still see the same serial port read blocked when the file check or copy call is delayed. I have also tried setting the ReadFile to work asynchronously but that had no effect. I believe I am dealing with some low-level windows layer that no matter the language it exhibits a block on a shared resource -- and only when the application is executing under a single .NET process protected by Themida which evidently installs some hooks to allow .NET execution. At this time converting the entire application away from .NET is not an option. Nor is separating out the file copy logic to a separate task. I am wondering if anyone else has more knowledge of how a file operation can block another thread reading from a system port. I have included here example applications that show the problem: https://db.tt/cNMYfEIg - VB.NET https://db.tt/Y2lnTqw7 - MFC They are Visual Studio 2010 solutions. When running the themida protected exe, you can see when the FileThread counter pauses (executing the File.Exists call) while the ReadThread counter also pauses. When running non-protected visual studio output exe, the ReadThread counter does not pause which is how we expect it to function. Thanks!

    Read the article

  • Unnecessary Java context switches

    - by Paul Morrison
    I have a network of Java Threads (Flow-Based Programming) communicating via fixed-capacity channels - running under WindowsXP. What we expected, based on our experience with "green" threads (non-preemptive), would be that threads would switch context less often (thus reducing CPU time) if the channels were made bigger. However, we found that increasing channel size does not make any difference to the run time. What seems to be happening is that Java decides to switch threads even though channels aren't full or empty (i.e. even though a thread doesn't have to suspend), which costs CPU time for no apparent advantage. Also changing Thread priorities doesn't make any observable difference. My question is whether there is some way of persuading Java not to make unnecessary context switches, but hold off switching until it is really necessary to switch threads - is there some way of changing Java's dispatching logic? Or is it reacting to something I didn't pay attention to?! Or are there other asynchronism mechanisms, e.g. Thread factories, Runnable(s), maybe even daemons (!). The answer appears to be non-obvious, as so far none of my correspondents has come up with an answer (including most recently two CS profs). Or maybe I'm missing something that's so obvious that people can't imagine my not knowing it... I've added the send and receive code here - not very elegant, but it seems to work...;-) In case you are wondering, I thought the goLock logic in 'send' might be causing the problem, but removing it temporarily didn't make any difference. I have added the code for send and receive... public synchronized Packet receive() { if (isDrained()) { return null; } while (isEmpty()) { try { wait(); } catch (InterruptedException e) { close(); return null; } if (isDrained()) { return null; } } if (isDrained()) { return null; } if (isFull()) { notifyAll(); // notify other components waiting to send } Packet packet = array[receivePtr]; array[receivePtr] = null; receivePtr = (receivePtr + 1) % array.length; //notifyAll(); // only needed if it was full usedSlots--; packet.setOwner(receiver); if (null == packet.getContent()) { traceFuncs("Received null packet"); } else { traceFuncs("Received: " + packet.toString()); } return packet; } synchronized boolean send(final Packet packet, final OutputPort op) { sender = op.sender; if (isClosed()) { return false; } while (isFull()) { try { wait(); } catch (InterruptedException e) { indicateOneSenderClosed(); return false; } sender = op.sender; } if (isClosed()) { return false; } try { receiver.goLock.lockInterruptibly(); } catch (InterruptedException ex) { return false; } try { packet.clearOwner(); array[sendPtr] = packet; sendPtr = (sendPtr + 1) % array.length; usedSlots++; // move this to here if (receiver.getStatus() == StatusValues.DORMANT || receiver.getStatus() == StatusValues.NOT_STARTED) { receiver.activate(); // start or wake up if necessary } else { notifyAll(); // notify receiver // other components waiting to send to this connection may also get // notified, // but this is handled by while statement } sender = null; Component.network.active = true; } finally { receiver.goLock.unlock(); } return true; }

    Read the article

  • WPF BackgroundWorker Execution

    - by Sanju
    Hi All, I've been programming C# for a while now (I'm a Computer Science major), and have never had to implement threading. I am currently building an application for a client that requires threading for a series of operations. Due to the nature of the client/provider agreement, I cannot release the source I am working with. The code that I have posted is in a general form. Pretty much the basic idea of what I am implementing, excluding the content specific source. The first Snippet demonstrates my basic structure, The Progress class is a custom progress window that is displayed as a dialog to prevent user UI interaction. I am currently using the code to complete database calls based on a collection of objects in another area of the application code. For example, I have a collection of "Objects" of one of my custom classes, that I perform these database calls on or on behalf of. My current set up works just fine when I call the "GeneralizedFunction" one and only one time. What I need to do is call this function once for every object in the collection. I was attempting to use a foreach loop to iterate through the collection, then I tried a for loop. For both loops, the result was the same. The Async operation performs exactly as desired for the first item in the collection. This, however, is the only one it works for. For each subsequent item, the progress box (my custom window) displays and immediately closes. In terms of the database calls, the calls for the first item in the collection are the only ones that successfully complete. All others aren't attempted. I've tried everything that I know and don't know to do, but I just cannot seem to get it to work. How can I get this to work for my entire collection? Any and all help is very greatly appreciated. Progress progress; BackgroundWorker worker; // Cancel the current process private void CancelProcess(object sender, EventArgs e) { worker.CancelAsync(); } // The main process ... "Generalized" private void GeneralizedFunction() { progress = new Progress(); progress.Cancel += CancelProcess; progress.Owner = this; Dispatcher pDispatcher = progress.Dispatcher; worker = new BackgroundWorker(); worker.WorkerSupportsCancellation = true; object[] workArgs = { arg1, arg2, arg3}; worker.DoWork += delegate(object s, DoWorkEventArgs args) { /* All main logic here */ foreach(Class ClassObject in ClassObjectCollection) { //Some more logic here UpdateProgressDelegate update = new UpdateProgressDelegate(updateProgress); pDispatcher.BeginInvoke(update, arg1,arg2,arg3); Thread.Sleep(1000); } }; worker.RunWorkerCompleted += delegate(object s, RunWorkerCompletedEventArgs args) { progress.Close(); }; worker.RunWorkerAsync(workArgs); progress.ShowDialog(); } public delegate void UpdateProgressDelegate(arg1,arg2,arg3); private void updateProgress(arg1,arg2,arg3) { //Update progress }

    Read the article

  • use network drives as mount points during installation?

    - by ajsie
    is it possible to use network storage locations as mount points during installation? cause i want to separate system (ubuntu) with data (personal files). eg. if i have 5 computers i don't want to recreate /home/david 5 times. so i want to mount networkdrive/home to /home in local ubuntu server. so ALL users home folders could be used and maybe also networkdrive/projects to /projects. in that way its ok if i by accident repartitioned the local ubuntu server cause all data is not there on that server, but in the data server. is separating "data" from "logic" good in this case? and is it possible? what protocol should i use for the mapping over internet? (maybe the server is in Sweden, and the data is in Norway). thanks.

    Read the article

  • Will Bluetooth hands-free drivers be installed if BT stack doesn't support A2DP?

    - by AndrejaKo
    I have a hands-free device which has no problems being paired with windows and I can set it to be the default sound output device, I don't actually hear anything on the unit, but it worked fine with GNU/Linux and with my mobile phone. From what I can see, the cause of that is usually a problem with Bluetooth stack. I think that I have Broadcom Bluetooth stack installed, so it should be working but it isn't. To make things better, my Bluetooth radio is integrated into my laptop and manufacturer isn't providing drivers for it and Broadcom itself recently pulled support, so I can't just reinstall the stack to make sure I have newest version.

    Read the article

  • One quarter of screen corrupted on MacBook Pro

    - by danyal
    I have a problem with my MacBook Pro's screen - here's a video: http://yfrog.com/4wm63z For those who prefer words, if you divide the screen vertically into 4 columns, the second column is corrupted (flickering, and discoloured, usually with yellow). I took it to an Apple store and they said it could be the screen or the logic board, neither of which will be cheap to replace. However, occasionally this problem will completely go away. So before I part with my cash, or decide to turn this into an overpriced media center for my TV... could the problem be a loose cable, or something else cheaper to fix?

    Read the article

  • USB Wireless keyboards not registering Ctrl Alt Delete when computer boots

    - by Donovan
    I've recently installed a new PC at work. Its a Dell Optiplex 9010. I bought a USB wireless keyboard and mouse from Dell and subsequently from Logitech to use with this PC. The Dell keyboard is a model KM632 and the logitech is an mk260. Both units work properly and have decent range. The issue is when the PC boots they keyboard (neither model) will register a Ctrl+Alt+Delete to the PC. I can say for sure the keyboards are still functional as the media keys will still produce a result (notably the sleep key on the mk260). My gut reaction is I'm dealing with an issue in the PC or Windows. I'm not sure where to start though. If I unplug and reinsert the USB dongle both units will work. Also, I don't use both they keyboards at the same time I bought the Logitech fearing the Dell unit was bad. Any ideas would be appreciated.

    Read the article

  • Dell EqualLogic vs. EMC VNXe [closed]

    - by Untalented
    We've been looking into SMB SANs and based on the competitive pricing I've been getting we're really liking these two array's. There are some pro's to both solutions, but I've unable to really decide which to choose. The EMC offers better expandability since you can buy an additional shelf (roughly $1200) and can add drives then to the array. However, the Dell unit is still very nice. Can anyone comment on their experiences with the two and thoughts on this? Also, to get the VMware Storage API support you need VMware Enterprise. How much additional performance does this provide? It's roughly $15k more than the Essentials Plus bundle we're looking at (this is a small environment [3 Hosts 1 Array].

    Read the article

  • Zabbix - Some of the monitored items dont get refreshd. how to find the reason?

    - by Niro
    I'm experiencing a strange issue with Zabbix monitoring a MySQL server. Most of the data from the server such as MySQL queries per second and MySQL uptime , Buffers memory etc. update nicely while some data like CPU iowait time (avg1) , Host local time ,MySQL number of threads and other items which were monitored in the past has last check time of about a week ago. I can't find any logic in this, for example Mysql number of threads and Mysql queries per second are obtained in a similar way so it does not make sense one of them is monitored and one is not. Please help- how can I fix this?

    Read the article

  • Canon LiDE 600F FAU on Snow Leopard?

    - by jdmuys
    I have been able to use my Canon LiDE 600F scanner under Snow Leopard to scan paper sheet, after installing Canon's latest driver software. However, I cannot find a way to make the FAU (Film Adaptor Unit) to work: Canon's software want to calibrate it first and gives an error message "Calibration cannot be performed. Pull out the film. 182.0.0". (of course there is no film). Hamrick's VueScan doesn't seem to support the FAU Apple's Image Capture doesn't propose a film option either Did I miss something? Did somebody manage to scan film (positive or negative) using the LiDE 600F under Snow Leopard? Many thanks

    Read the article

  • Ubuntu 10.04 recognizing USB 2.0 external HD as USB 1.1

    - by btucker
    When I connect the USB 2.0 drive I see this: usb 1-4.3: new full speed USB device using ohci_hcd and address 5 so I know it's getting seen as USB 1.1. usb-devices shows that it really is USB 2.0 and connected to a USB 2.0 hub: T: Bus=01 Lev=01 Prnt=01 Port=03 Cnt=01 Dev#= 2 Spd=12 MxCh= 4 D: Ver= 2.00 Cls=09(hub ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=05e3 ProdID=0608 Rev=77.61 S: Product=USB2.0 Hub C: #Ifs= 1 Cfg#= 1 Atr=e0 MxPwr=100mA I: If#= 0 Alt= 0 #EPs= 1 Cls=09(hub ) Sub=00 Prot=00 Driver=hub T: Bus=01 Lev=02 Prnt=02 Port=01 Cnt=01 Dev#= 4 Spd=12 MxCh= 0 D: Ver= 2.00 Cls=00(>ifc ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=13fd ProdID=1340 Rev=02.10 S: Manufacturer=Generic S: Product=External C: #Ifs= 1 Cfg#= 1 Atr=c0 MxPwr=2mA I: If#= 0 Alt= 0 #EPs= 2 Cls=08(stor.) Sub=06 Prot=50 Driver=usb-storage It seems the problem is that root hub is: T: Bus=01 Lev=00 Prnt=00 Port=00 Cnt=00 Dev#= 1 Spd=12 MxCh=10 D: Ver= 1.10 Cls=09(hub ) Sub=00 Prot=00 MxPS=64 #Cfgs= 1 P: Vendor=1d6b ProdID=0001 Rev=02.06 S: Manufacturer=Linux 2.6.32-25-server ohci_hcd S: Product=OHCI Host Controller S: SerialNumber=0000:00:02.0 C: #Ifs= 1 Cfg#= 1 Atr=e0 MxPwr=0mA I: If#= 0 Alt= 0 #EPs= 1 Cls=09(hub ) Sub=00 Prot=00 Driver=hub And there's no mention of ehci_hcd. lsusb -t gives me: /: Bus 01.Port 1: Dev 1, Class=root_hub, Driver=ohci_hcd/10p, 12M |__ Port 4: Dev 2, If 0, Class=hub, Driver=hub/4p, 12M |__ Port 2: Dev 4, If 0, Class=stor., Driver=usb-storage, 12M |__ Port 3: Dev 5, If 0, Class=stor., Driver=usb-storage, 12M |__ Port 6: Dev 3, If 0, Class=stor., Driver=usb-storage, 12M It seems like I'm missing something which would allow the OS to see USB 2.0 devices. Can anyone point me in the right direction? EDIT Full lsusb -v output: Bus 001 Device 005: ID 13fd:1340 Initio Corporation Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x13fd Initio Corporation idProduct 0x1340 bcdDevice 2.10 iManufacturer 1 Generic iProduct 2 External iSerial 3 57442D574341595930323337 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 32 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xc0 Self Powered MaxPower 2mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk (Zip) iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0040 1x 64 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0040 1x 64 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Bus 001 Device 002: ID 05e3:0608 Genesys Logic, Inc. USB-2.0 4-Port HUB Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x05e3 Genesys Logic, Inc. idProduct 0x0608 USB-2.0 4-Port HUB bcdDevice 77.61 iManufacturer 0 iProduct 1 USB2.0 Hub iSerial 0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 100mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0001 1x 1 bytes bInterval 255 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 4 wHubCharacteristic 0x00e0 Ganged power switching Ganged overcurrent protection Port indicators bPwrOn2PwrGood 50 * 2 milli seconds bHubContrCurrent 100 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0103 power enable connect Port 3: 0000.0103 power enable connect Port 4: 0000.0100 power Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 1 Single TT bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Bus 001 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 0 Full speed (or root) hub bMaxPacketSize0 64 idVendor 0x1d6b Linux Foundation idProduct 0x0001 1.1 root hub bcdDevice 2.06 iManufacturer 3 Linux 2.6.32-25-server ohci_hcd iProduct 2 OHCI Host Controller iSerial 1 0000:00:02.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0002 1x 2 bytes bInterval 255 Hub Descriptor: bLength 11 bDescriptorType 41 nNbrPorts 10 wHubCharacteristic 0x0002 No power switching (usb 1.0) Ganged overcurrent protection bPwrOn2PwrGood 1 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 0x00 PortPwrCtrlMask 0xff 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0100 power Port 4: 0000.0103 power enable connect Port 5: 0000.0100 power Port 6: 0000.0103 power enable connect Port 7: 0000.0100 power Port 8: 0000.0100 power Port 9: 0000.0100 power Port 10: 0000.0100 power Device Status: 0x0003 Self Powered Remote Wakeup Enabled

    Read the article

  • Comparing, merging, calculating colums of data in Excel

    - by hickster
    I would like to create a formula that a) compares four columns of data (see below) Sep Oct name units name units apple 2 apple 3 pear 3 pear 7 orange 4 banana 6 banana 3 toffee 5 then b) merges the two "names" column into one column, dropping any duplicates but still retaining the two unit columns (for months Sep and Oct) Sep Oct name units units apple 2 3 pear 3 7 orange 4 0 banana 3 6 toffee 0 6 then c) creates a third column that compares "Sep units" against "Oct units" and produces the total in the "difference" column Sep Oct name units units difference apple 2 3 1 pear 3 7 4 orange 4 0 -4 banana 3 6 3 toffee 0 6 6

    Read the article

  • Connection Reset by Peer error with Apache and JBoss 7.1.1

    - by vikingz
    We are seeing errors on some of our QA testing scripts that intermittently throw Connection Reset By Peer errors. The Test scripts submit requests via F5 which forwards requests to Apache (2.2.21) with a mod_jk load_balancer with the following setting for each worker in the worker.property worker1 props worker.worker1.type=ajp13 worker.worker1.port=8109 worker.worker1.lbfactor=1 worker.worker1.host=skunkhost1.com worker.worker1.connection_pool_timeout=30 and here is what is in the JBoss domain.xml for the AJP port from JBoss 7.1.1 <unbounded-queue-thread-pool name="SKUNKY.APP.AJP"> <max-threads count="300"/> <keepalive-time time="3" unit="minutes"/> </unbounded-queue-thread-pool> Here is httpd.conf Timeout 300 KeepAlive On KeepAliveTimeout 15 MaxKeepAliveRequests 100 TraceEnable Off My question is that is it posisbe that apache times out and closes the connection while jboss is still ready and working on the request? What might be causing the Connection Reset By Peer error?what am i missing here? Any help is majorly appreciated!! Sincerely KK

    Read the article

  • Puppet causes endless restarts of CUPS (how does one prevent this)

    - by Purfideas
    Hi! It makes sense, and is in fact suggested on this site, to have a critical file change trigger a service restart with puppet meta-parameters (such as notify or subscribe). For example: ## file definition for printers.conf file { "/etc/cups/printers.conf": [snip], source => "puppet:///module/etc/cups/printers.conf" } ## service definition for sshd service { 'cups': ensure => running, subscribe => File['/etc/cups/printers.conf'] } But in the case of CUPS, this triggers and endless loop of restarts; the logic works like this: Change puppetmaster's version of /etc/cups/printers.conf puppetmaster pushes new version to client, triggering cups restart cupsd restart insists on putting its own time stamp at the top of printers.conf, 'Written by cupsd...' This change will be seen as out of date, so after runinterval, we return to (1). Is there a way to suppress cupsd's need to time stamp the file? Or is there a puppet trick that could help here? Thanks!

    Read the article

  • Php template caching design

    - by Thomas
    Hello to all, I want to include caching in my app design. Caching templates for starters. The design I have used so far is very modular. I have created an ORM implementation for all my tables and each table is represented by the corresponding class. All the requests are handled by one controller which routes them to the appropriate webmethod functions. I am using a template class for handling UI parts. What I have in mind for caching includes the implementation of a separate Cache class for handling caching with the flexibility to either store in files, apc or memcache. Right now I am testing with file caching. Some thoughts Should I include the logic of checking for cached versions in the Template class or in the webmethods which handle the incoming requests and which eventually call the Template class. In the first case, things are pretty simple as I will not have to change anything more than pass the template class an extra argument (whether to load from cache or not). In the second case however, I am thinking of checking for a cached version immediately in the webmethod and if found return it. This will save all the processing done until the logic reaches the template (first case senario). Both senarios however, rely on an accurate mechanism of invalidating caches, which brings as to Invalidating caches As I see it (and you can add your input freely) a template cached file, becomes invalidate if: a. the expiration set, is reached. b. the template file itself is updated (ie by the developer when adding a new line) c. the webmethod that handles the request changes (ie the developer adds/deletes something in the code) d. content coming from the db and ending in the template file is modified I am thinking of storing a json encoded array inside the cached file. The first value will be the expiration timestamp of the cache. The second value will be the modification time of the php file with the code handling the request (to cope with option c above) The third will be the content itself The validation process I am considering, according to the above senarios, is: a. If the expiration of the cached file (stored in the array) is reached, delete the cache file b. if the cached file's mod time is smaller than the template's skeleton file mod time, delete the cached file c. if the mod time of the php file is greated than the one stored in the cache, delete the cached file. d. This is tricky. In the ORM implementation I ahve added event handlers (which fire when adding, updating, deleting objects). I could delete the cache file every time an object thatprovides content to the template, is modified. The problem is how to keep track which cached files correpond to each schema object. Take this example, a user has his shortprofile page and a full profile page (2 templates) These templates can be cached. Now, every time the user modifies his profile, the event handler would need to know which templates or cached files correspond to the User, so that these files can be deleted. I could store them in the db but I am looking for a beter approach

    Read the article

  • Run Wave Trusted Drive Manager from a bootable CD, recover crashed enrypted SSD?

    - by TigerInCanada
    Is there a way to run Wave Trusted Drive Manager from a live-cd to access a non-bootable SSD with Full Disk Encyption hard disk? http://www.wave.com/products/tdm.asp The crashed disk is a Samsung SSD PB22-JS3, 128Gb. Is has bad blocks at 128-block intervals. If the SSD password could be unset, is sending the unit for disaster recovery possible? What might cause a nearly new SSD to crash in this way, and what is the probability of it happening again? We have other units in service an I can do without every laptop disk in the company crashing...

    Read the article

  • I have to shard a mysql database. I want to start with 12 shards on 2 machines. What is the best w

    - by Tim
    All tables are InnoDb. I would rather not use mysqldump, because the shard sizes will be about 200 GB (about 700 million rows), and that will take too long. I was hoping to just stop mysql for an hour, copy the data files to a new machine, and start back up. But you can't do this with InnoDb, as some data is in the shared tablespace. Even if I have the innodb_file_per_table option set. This is not a website, but a custom application, used by tens of thousands right now, so uptime and performance are important. I suppose I could add logic into my server application to allow for gradual rebalancing / moving of a shard. Does anyone have a better idea?

    Read the article

< Previous Page | 200 201 202 203 204 205 206 207 208 209 210 211  | Next Page >