  • Multiple routers, subnets, gateways etc

    - by allentown
    My current setup is: Cable modem dishes out 13 static IP's (/28), a GB switch is plugged into the cable modem, and has access to those 13 static IP's, I have about 6 "servers" in use right now. The cable modem is also a firewall, DHCP server, and 3 port 10/100 switch. I am using it as a firewall, but not currently as a DHCP server. I have plugged into the cable modem, two network cables, one which goes to the WAN port of a Linksys Dual Band Wireless 10/100/1000 router/switch. Into the linksys are a few workstations, a few printers, and some laptops connecting to wifi. I set the Linksys to use take static IP, and enabled DHCP for the workstations, printers, etc in 192.168.1.1/24. The network for the Linksys is mostly self contained, backups go to a SAN, on that network, it all happens through that switch, over GB. But I also get internet access from it as well via the cable modem using one static IP. This all works, however, I can not "see" the static IP machines when I am on the Linksys. I can get to them via ssh and other protocols, and if I want to from "outside", I open holes, like 80, 25, 587, 143, 22, etc. The second wire, from the cable modem/fireall/switch just uplinks to the managed GB switch. What are the pros and cons of this? I do not like giving up the static IP to the Linksys. I basically have a mixed network of public servers, and internal workstations. I want the public servers on public IP's because I do not want to mess with port forwarding and mappings. Is it correct also, that if someone breaches the Linksys wifi, they still would have a hard time getting to the static IP range, just by nature of the network topology? Today, just for a test, I toggled on the DHCP in the firewall/cable modem at 10.1.10.1/24 range, the Linksys is n the 192.168.1.100/24 range. At that point, all the static IP machines still had in and out access, but Linksys was unreachable. The cable modem only has 10/100 ports, so I will not plug anything but the network drop into it, which is 50Mb/10Mb. Which makes me think this could be less than ideal, as transfers from the workstation network to the server network will be bottlenecked at 100Mb when I have 1000Mb available. I may not need to solve that, if isolation is better though. I do not move a lot of data, if any, from Linsys network to server network, so for it to pretend to be remote is ok. Should I approach this any different? I could enable DHCP on the cable modem/firewall, it should still send out the statics to the GB switch, but will also be a DHCP in 10.1.10.1/24 range? I can then plug the Linksys into the GB switch, which is now picking up statics and the 10.1.10.1/24 ranges, tell the Linksys to use 10.1.10.5 or so. Now, do I disable DHCP on the Linksys, and the cable modem/firewall will pass through the statics and 10.0.10.1/24 ranges as well? Or, could I open a second DHCP pool on the Linksys? I guess doing so gives me network isolation again, but it is just the reverse of what I have now. But I get out of the bottleneck, not that the Linksys could ever really touch real GB speeds anyway, but the managed switch certainly can. This is all because 13 statics are not that many. Right now, 6 "servers", the Linksys, a managed switch, a few SSL certs, and I am running out. I do not want to waste a static IP on the managed GB switch, or the Linksys, unless it provides me some type of benefit. Final question, under my current setup, if I am on a workstation, sitting at 192.168.1.109, the Linksys, with GB, and I send a file over ssh to the static IP machine, is that literally leaving the internet, and coming back in, or does it stay local? To me it seems like: Workstation (192.168.1.109) -> Linksys DHCP -> Linksys Static IP -> Cable Modem -> Server ( and it hits the 10/100 ports on the cable modem, slowing me down. But does it round trip the network, leave and come back in, limiting me to the 50/10 internet speeds? *These are all made up numbers, I do not use default router IP's as I will one day add a VPN, and do not want collisions. I need some recommendations, do I want one big network, or two isolated ones. Printers these days need an IP, everything does, I can not get autoconf/bonjour to be reliable on most printers. but I am also not sure I want the "server" side of my operation to be polluted by the workstation side of my operation. Unless there is some magic subetting I have not learned yet, here is what I am thinking: Cable modem 10/100, has 13 static IP, publicly accessible -> Enable DHCP on the cable modem -> Cable modem plugs into managed switch -> Managed switch gets 10.1.10.1 ssh, telnet, https admin management address -> Managed switch sends static IP's to to servers -> Plug Linksys into managed switch, giving it 10.1.10.2 static internally in Linksys admin -> Linksys gets assigned 10.1.10.x as its DHCP sending range -> Local printers, workstations, iPhones etc, connect to this -> ( Do I enable DHCP or disable it on the Linksys, just define a non over lapping range, or create an entirely new DHCP at 10.1.50.0/24, I think I am back isolated again with that method too? ) Thank you for any suggestions. This is the first time I have had to deal with less than a /24, and most are larger than that, but it is just a drop to a cabinet. Otherwise, it's a router, a few repeaters, and soho stuff that is simple, with one IP. I know a few may suggest going all DHCP on the servers, and I may one day, just not now, there has been too much moving of gear for me to be interested in that, and I would want something in the Catalyst series to deal with that.

    Read the article

  • How to diagnose failing 6Gbps SATA connection?

    - by whitequark
    I have a Samsung RC530 notebook and OCZ Vertex-3 6Gbps SATA SSD working in AHCI mode. # dmesg | grep DMI SAMSUNG ELECTRONICS CO., LTD. RC530/RC730/RC530/RC730, BIOS 03WD.M008.20110927.PSA 09/27/2011 # lspci -nn 00:1f.2 SATA controller [0106]: Intel Corporation 6 Series/C200 Series Chipset Family 6 port SATA AHCI Controller [8086:1c03] (rev 04) # sdparm -a /dev/sda /dev/sda: ATA OCZ-VERTEX3 2.15 At the boot, the following messages are present in dmesg (I am running Debian wheezy @ Linux 3.2.8): # dmesg | grep -iE '(ata|ahci)' [ 5.179783] ahci 0000:00:1f.2: version 3.0 [ 5.179802] ahci 0000:00:1f.2: PCI INT B -> GSI 19 (level, low) -> IRQ 19 [ 5.179864] ahci 0000:00:1f.2: irq 42 for MSI/MSI-X [ 5.195424] ahci 0000:00:1f.2: AHCI 0001.0300 32 slots 6 ports 6 Gbps 0x5 impl SATA mode [ 5.195429] ahci 0000:00:1f.2: flags: 64bit ncq sntf pm led clo pio slum part ems apst [ 5.195436] ahci 0000:00:1f.2: setting latency timer to 64 [ 5.204035] scsi0 : ahci [ 5.204301] scsi1 : ahci [ 5.204447] scsi2 : ahci [ 5.204592] scsi3 : ahci [ 5.204682] scsi4 : ahci [ 5.204799] scsi5 : ahci [ 5.204917] ata1: SATA max UDMA/133 abar m2048@0xf7c06000 port 0xf7c06100 irq 42 [ 5.204920] ata2: DUMMY [ 5.204923] ata3: SATA max UDMA/133 abar m2048@0xf7c06000 port 0xf7c06200 irq 42 [ 5.204924] ata4: DUMMY [ 5.204926] ata5: DUMMY [ 5.204927] ata6: DUMMY [ 5.523039] ata3: SATA link up 1.5 Gbps (SStatus 113 SControl 300) [ 5.525911] ata3.00: ATAPI: TSSTcorp CDDVDW SN-208BB, SC00, max UDMA/100 [ 5.531006] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) [ 5.533703] ata3.00: configured for UDMA/100 [ 5.542790] ata1.00: ATA-8: OCZ-VERTEX3, 2.15, max UDMA/133 [ 5.542800] ata1.00: 117231408 sectors, multi 16: LBA48 NCQ (depth 31/32), AA [ 5.552751] ata1.00: configured for UDMA/133 [ 5.553050] scsi 0:0:0:0: Direct-Access ATA OCZ-VERTEX3 2.15 PQ: 0 ANSI: 5 [ 5.559621] scsi 2:0:0:0: CD-ROM TSSTcorp CDDVDW SN-208BB SC00 PQ: 0 ANSI: 5 [ 5.564059] sd 0:0:0:0: [sda] 117231408 512-byte logical blocks: (60.0 GB/55.8 GiB) [ 5.564127] sd 0:0:0:0: [sda] Write Protect is off [ 5.564131] sd 0:0:0:0: [sda] Mode Sense: 00 3a 00 00 [ 5.564158] sd 0:0:0:0: [sda] Write cache: enabled, read cache: enabled, doesn't support DPO or FUA [ 5.564582] sda: sda1 [ 5.564810] sd 0:0:0:0: [sda] Attached SCSI disk [ 5.572006] sr0: scsi3-mmc drive: 16x/24x writer dvd-ram cd/rw xa/form2 cdda tray [ 5.572010] cdrom: Uniform CD-ROM driver Revision: 3.20 [ 5.572189] sr 2:0:0:0: Attached scsi CD-ROM sr0 [ 6.717181] ata1.00: exception Emask 0x50 SAct 0x1 SErr 0x280900 action 0x6 frozen [ 6.717238] ata1.00: irq_stat 0x08000000, interface fatal error [ 6.717291] ata1: SError: { UnrecovData HostInt 10B8B BadCRC } [ 6.717342] ata1.00: failed command: READ FPDMA QUEUED [ 6.717395] ata1.00: cmd 60/50:00:20:39:58/00:00:00:00:00/40 tag 0 ncq 40960 in [ 6.717396] res 40/00:00:20:39:58/00:00:00:00:00/40 Emask 0x50 (ATA bus error) [ 6.717503] ata1.00: status: { DRDY } [ 6.717553] ata1: hard resetting link [ 7.033417] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) [ 7.055234] ata1.00: configured for UDMA/133 [ 7.055262] ata1: EH complete [ 7.147280] ata1.00: exception Emask 0x10 SAct 0xf8 SErr 0x280100 action 0x6 frozen [ 7.147340] ata1.00: irq_stat 0x08000000, interface fatal error [ 7.147393] ata1: SError: { UnrecovData 10B8B BadCRC } [ 7.147460] ata1.00: failed command: READ FPDMA QUEUED [ 7.147529] ata1.00: cmd 60/08:18:88:17:41/00:00:02:00:00/40 tag 3 ncq 4096 in [ 7.147531] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.147691] ata1.00: status: { DRDY } [ 7.147754] ata1.00: failed command: READ FPDMA QUEUED [ 7.147821] ata1.00: cmd 60/00:20:f8:42:4c/01:00:02:00:00/40 tag 4 ncq 131072 in [ 7.147822] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.147977] ata1.00: status: { DRDY } [ 7.148036] ata1.00: failed command: READ FPDMA QUEUED [ 7.148100] ata1.00: cmd 60/50:28:f8:43:4c/00:00:02:00:00/40 tag 5 ncq 40960 in [ 7.148101] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.148255] ata1.00: status: { DRDY } [ 7.148315] ata1.00: failed command: READ FPDMA QUEUED [ 7.148379] ata1.00: cmd 60/00:30:50:98:64/01:00:02:00:00/40 tag 6 ncq 131072 in [ 7.148380] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.148534] ata1.00: status: { DRDY } [ 7.148593] ata1.00: failed command: READ FPDMA QUEUED [ 7.148657] ata1.00: cmd 60/00:38:50:99:64/01:00:02:00:00/40 tag 7 ncq 131072 in [ 7.148658] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.148813] ata1.00: status: { DRDY } [ 7.148875] ata1: hard resetting link [ 7.464842] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) [ 7.486794] ata1.00: configured for UDMA/133 [ 7.486822] ata1: EH complete [ 7.546395] ata1.00: exception Emask 0x10 SAct 0x2f SErr 0x280100 action 0x6 frozen [ 7.546470] ata1.00: irq_stat 0x08000000, interface fatal error [ 7.546531] ata1: SError: { UnrecovData 10B8B BadCRC } [ 7.546588] ata1.00: failed command: READ FPDMA QUEUED [ 7.546648] ata1.00: cmd 60/00:00:e0:4b:61/01:00:02:00:00/40 tag 0 ncq 131072 in [ 7.546649] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.546794] ata1.00: status: { DRDY } [ 7.546847] ata1.00: failed command: READ FPDMA QUEUED [ 7.546906] ata1.00: cmd 60/00:08:90:2f:48/01:00:02:00:00/40 tag 1 ncq 131072 in [ 7.546907] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.547053] ata1.00: status: { DRDY } [ 7.547106] ata1.00: failed command: READ FPDMA QUEUED [ 7.547165] ata1.00: cmd 60/00:10:90:30:48/01:00:02:00:00/40 tag 2 ncq 131072 in [ 7.547166] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.547310] ata1.00: status: { DRDY } [ 7.547363] ata1.00: failed command: READ FPDMA QUEUED [ 7.547422] ata1.00: cmd 60/00:18:50:c7:64/01:00:02:00:00/40 tag 3 ncq 131072 in [ 7.547423] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.547568] ata1.00: status: { DRDY } [ 7.547621] ata1.00: failed command: READ FPDMA QUEUED [ 7.547681] ata1.00: cmd 60/00:28:e0:4c:61/01:00:02:00:00/40 tag 5 ncq 131072 in [ 7.547682] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.547825] ata1.00: status: { DRDY } [ 7.547882] ata1: hard resetting link [ 7.864408] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) [ 7.886351] ata1.00: configured for UDMA/133 [ 7.886375] ata1: EH complete [ 7.890012] ata1: limiting SATA link speed to 3.0 Gbps [ 7.890016] ata1.00: exception Emask 0x10 SAct 0x7 SErr 0x280100 action 0x6 frozen [ 7.890093] ata1.00: irq_stat 0x08000000, interface fatal error [ 7.890152] ata1: SError: { UnrecovData 10B8B BadCRC } [ 7.890210] ata1.00: failed command: READ FPDMA QUEUED [ 7.890272] ata1.00: cmd 60/00:00:90:33:48/01:00:02:00:00/40 tag 0 ncq 131072 in [ 7.890273] res 40/00:10:e0:4f:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.890418] ata1.00: status: { DRDY } [ 7.890472] ata1.00: failed command: READ FPDMA QUEUED [ 7.890530] ata1.00: cmd 60/00:08:90:34:48/01:00:02:00:00/40 tag 1 ncq 131072 in [ 7.890531] res 40/00:10:e0:4f:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.890672] ata1.00: status: { DRDY } [ 7.890724] ata1.00: failed command: READ FPDMA QUEUED [ 7.890781] ata1.00: cmd 60/78:10:e0:4f:61/00:00:02:00:00/40 tag 2 ncq 61440 in [ 7.890782] res 40/00:10:e0:4f:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error) [ 7.890925] ata1.00: status: { DRDY } [ 7.890981] ata1: hard resetting link [ 8.208021] ata1: SATA link up 3.0 Gbps (SStatus 123 SControl 320) [ 8.230100] ata1.00: configured for UDMA/133 [ 8.230124] ata1: EH complete Looks like the SATA interface tries to use 6Gbps link, then fails miserably and Linux fallbacks to 3Gbps. This is somewhat fine for me, as the system boots successfully each time and works under high load (cd linux-3.2.8; make -j16). I've also ran memtest86+ and it did not find any errors. What concerns me more is that Grub sometimes takes a long time to load the images and/or fails to load itself completely. The error is consistent and is probablistic: that is, each time I boot I have a certain chance to fail. Actually, I have a slight suspiction on the cause of the failure. Look at the cabling: What kind of engineer does it this way? Nah. Even 1Gbps Ethernet hardly tolerates cables bent over a small angle, and there you have 6Gbps SATA. How cound I determine and fix the cause of errors and/or switch the link to 3Gbps mode permanently?

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

< Previous Page | 17 18 19 20 21