Search Results

Search found 18244 results on 730 pages for 'controller action'.

Page 217/730 | < Previous Page | 213 214 215 216 217 218 219 220 221 222 223 224  | Next Page >

  • Problem setting up DL360G5 with scsi RAID

    - by ernelli
    I have a problem with reinstalling OS on a DL360G5. The BIOS [F9] do not detect any disc controllers and the HP SmartSetup did not find any compatible controllers. Inside the server, the two SCSI disks are conncted to a RAID controller using BCM8603 chipset. How is disc contoller supposed to be setup? I have tried to do a full BIOS reset. EDIT At the moment we suspect that the Smart Array controller E200i/412205-001 is broken. Are there any status LED's that indicate failure or success during start up? At the moment all LED's are off.

    Read the article

  • Windows XP Home Edition SP3 cant recognise PCMIA SD Card

    - by Pozo
    System Specifications: Laptop : Dell Inspiron 6000 OS: Windows Home Edition SP3 SD Adapter: Hagiwara Smart Media Adapter I inserted the card into the slot, windows xp recognises the device, lists the pcmia controller on the device manager list, an entry appears under the IDE ATA/ATAPI category on the device manager as well. However, the device does not show under my computer and the driver does not get assigned a letter number. I checked the system logs from the device manager and there were no logged errors. Checking the Hagiwara support website, the manufacturer indicates that the adapter driver is the same as the windows xp pcmia controller. Checking Dell's website, no specific drivers were listed for that either. General Search on the web indicates that multiple people face similar problems with their SD cards, yet none actually spell out the route issue that causes this. Please let me know if you have any suggestions for further debugging. Thanks in advance

    Read the article

  • Why is my mdadm raid-1 recovery so slow?

    - by dimmer
    On a system I'm running Ubuntu 10.04. My raid-1 restore started out fast but quickly became ridiculously slow (at this rate the restore will take 150 days!): dimmer@paimon:~$ cat /proc/mdstat Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md0 : active raid1 sdc1[2] sdb1[1] 1953513408 blocks [2/1] [_U] [====>................] recovery = 24.4% (477497344/1953513408) finish=217368.0min speed=113K/sec unused devices: <none> Eventhough I have set the kernel variables to reasonably quick values: dimmer@paimon:~$ cat /proc/sys/dev/raid/speed_limit_min 1000000 dimmer@paimon:~$ cat /proc/sys/dev/raid/speed_limit_max 100000000 I am using 2 2.0TB Western Digital Hard Disks, WDC WD20EARS-00M and WDC WD20EARS-00J. I believe they have been partitioned such that their sectors are aligned. dimmer@paimon:/sys$ sudo parted /dev/sdb GNU Parted 2.2 Using /dev/sdb Welcome to GNU Parted! Type 'help' to view a list of commands. (parted) p Model: ATA WDC WD20EARS-00M (scsi) Disk /dev/sdb: 2000GB Sector size (logical/physical): 512B/512B Partition Table: gpt Number Start End Size File system Name Flags 1 1049kB 2000GB 2000GB ext4 (parted) unit s (parted) p Number Start End Size File system Name Flags 1 2048s 3907028991s 3907026944s ext4 (parted) q dimmer@paimon:/sys$ sudo parted /dev/sdc GNU Parted 2.2 Using /dev/sdc Welcome to GNU Parted! Type 'help' to view a list of commands. (parted) p Model: ATA WDC WD20EARS-00J (scsi) Disk /dev/sdc: 2000GB Sector size (logical/physical): 512B/4096B Partition Table: gpt Number Start End Size File system Name Flags 1 1049kB 2000GB 2000GB ext4 I am beginning to think that I have a hardware problem, otherwise I can't imagine why the mdadm restore should be so slow. I have done a benchmark on /dev/sdc using Ubuntu's disk utility GUI app, and the results looked normal so I know that sdc has the capability to write faster than this. I also had the same problem on a similar WD drive that I RMAd because of bad sectors. I suppose it's possible they sent me a replacement with bad sectors too, although there are no SMART values showing them yet. Any ideas? Thanks. As requested, output of top sorted by cpu usage (notice there is ~0 cpu usage). iowait is also zero which seems strange: top - 11:35:13 up 2 days, 9:40, 3 users, load average: 2.87, 2.58, 2.30 Tasks: 142 total, 1 running, 141 sleeping, 0 stopped, 0 zombie Cpu(s): 0.0%us, 0.2%sy, 0.0%ni, 99.8%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 3096304k total, 1482164k used, 1614140k free, 617672k buffers Swap: 1526132k total, 0k used, 1526132k free, 535416k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 45 root 20 0 0 0 0 S 0 0.0 2:17.02 scsi_eh_0 1 root 20 0 2808 1752 1204 S 0 0.1 0:00.46 init 2 root 20 0 0 0 0 S 0 0.0 0:00.00 kthreadd 3 root RT 0 0 0 0 S 0 0.0 0:00.02 migration/0 4 root 20 0 0 0 0 S 0 0.0 0:00.17 ksoftirqd/0 5 root RT 0 0 0 0 S 0 0.0 0:00.00 watchdog/0 6 root RT 0 0 0 0 S 0 0.0 0:00.02 migration/1 ... dmesg errors, definitely looking like hardware: [202884.000157] ata5.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [202884.007015] ata5.00: failed command: FLUSH CACHE EXT [202884.013728] ata5.00: cmd ea/00:00:00:00:00/00:00:00:00:00/a0 tag 0 [202884.013730] res 40/00:00:ff:59:2e/00:00:35:00:00/e0 Emask 0x4 (timeout) [202884.033667] ata5.00: status: { DRDY } [202884.040329] ata5: hard resetting link [202889.400050] ata5: link is slow to respond, please be patient (ready=0) [202894.048087] ata5: COMRESET failed (errno=-16) [202894.054663] ata5: hard resetting link [202899.412049] ata5: link is slow to respond, please be patient (ready=0) [202904.060107] ata5: COMRESET failed (errno=-16) [202904.066646] ata5: hard resetting link [202905.840056] ata5: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [202905.849178] ata5.00: configured for UDMA/133 [202905.849188] ata5: EH complete [203899.000292] ata5.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [203899.007096] ata5.00: failed command: IDENTIFY DEVICE [203899.013841] ata5.00: cmd ec/00:01:00:00:00/00:00:00:00:00/00 tag 0 pio 512 in [203899.013843] res 40/00:00:ff:f9:f6/00:00:38:00:00/e0 Emask 0x4 (timeout) [203899.041232] ata5.00: status: { DRDY } [203899.048133] ata5: hard resetting link [203899.816134] ata5: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [203899.826062] ata5.00: configured for UDMA/133 [203899.826079] ata5: EH complete [204375.000200] ata5.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [204375.007421] ata5.00: failed command: IDENTIFY DEVICE [204375.014799] ata5.00: cmd ec/00:01:00:00:00/00:00:00:00:00/00 tag 0 pio 512 in [204375.014800] res 40/00:00:ff:0c:0f/00:00:39:00:00/e0 Emask 0x4 (timeout) [204375.044374] ata5.00: status: { DRDY } [204375.051842] ata5: hard resetting link [204380.408049] ata5: link is slow to respond, please be patient (ready=0) [204384.440076] ata5: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [204384.449938] ata5.00: configured for UDMA/133 [204384.449955] ata5: EH complete [204395.988135] ata5.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [204395.988140] ata5.00: failed command: IDENTIFY DEVICE [204395.988147] ata5.00: cmd ec/00:01:00:00:00/00:00:00:00:00/00 tag 0 pio 512 in [204395.988149] res 40/00:00:ff:0c:0f/00:00:39:00:00/e0 Emask 0x4 (timeout) [204395.988151] ata5.00: status: { DRDY } [204395.988156] ata5: hard resetting link [204399.320075] ata5: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [204399.330487] ata5.00: configured for UDMA/133 [204399.330503] ata5: EH complete

    Read the article

  • SCSI vs SATA? Is SCSI "actually" better?

    - by earlz
    Well, I was talking with a guy about servers the other day. I was a bit shocked whenever I asked him if there was any significant difference between SCSI and SATA and why he always uses SCSI. (note, I'm not sure if by SCSI he meant SAS) He told me that SCSI is always faster and that the drives are always more reliable.. I mean, this seems like a bold statement. He told me something about how SCSI will always be faster than SATA because the OS sends the SCSI (controller?) a request to get a file and it will build the file inside of the SCSI controller, instead of searching all over the disk.. which I do not understand how that would work, so I figure it is BS. SAS and SATA currently have equivalent data rate speeds.. Is there any true backing for his reasoning that SCSI is always faster and more reliable than SATA?

    Read the article

  • Nginx rewrite with Simple Machines Forum

    - by Kevin Worthington
    I am running Nginx 1.5.6 and I use the Simple Machines Forum software. Most rewrite rules seem to work properly, with the exception of the RSS feeds. In my Nginx configuration, I have the following line which is supposed to handle URLs which contain ".xml": rewrite ^/forum/(\.xml|xmlhttp)/?$ "/forum/index.php?pretty;action=$1" last; The above rule produces the following URL for the main forum, which returns a 403 Error: http://www.mydomain.com/forum/.xml/?type=rss I would like the rewrite rule to produce this type of URL, which returns code 200 (a real page): http://www.mydomain.com/forum/?type=rss;action=.xml Here is the entire block pertaining to the forum rewrites: http://pastebin.com/raw.php?i=tZkAibW3 I would really appreciate some help to create a rewrite rule to do that. Thanks.

    Read the article

  • Identify SATA hard drive

    - by Rob Nicholson
    Very similar question to: Physically Identify the failed hard drive But for Windows 2003 this time. Scenario: Four identical SATA hard drives plugged into motherboard (no RAID controller here) Configured as single drive in Windows as a spanned volume One of them is starting to fail with error "The driver detected a controller error on \Device\Harddisk3" How do you cross-reference Harddisk3 to the physical SATA connection on the motherboard so you know which drive to replace? I know replacing this drive will trash the spanned array requiring it to be rebuilt anyway so my rough and ready solution is: Delete the spanned partition Create individual partitions on each drive labelled E: F: G: and H: and work out which one is Harddisk3 Power down, remove each disk one at a time, power-up until the drive letter disappears But this seems a rather crude method of identifying the drive. The SATA connectors will be numbered on the motherboard but I appreciate this might not cross-match to what Windows calls them. Thanks, Rob.

    Read the article

  • Initiate a PHP class where class name is a variable

    - by ed209
    I need some help with an error I have not encountered before and can't seem to find anywhere. In a PHP mvc framework (just from a tutorial) I have the following: // Initiate the class $className = 'Controller_' . ucfirst($controller); if (class_exists($className)) { $controller = new $className($this->registry); } $className is showing the correct class name (case is also correct). But when I run it I get this in the apache error log (no php error) [Wed Mar 31 10:34:12 2010] [notice] child pid 987 exit signal Segmentation fault (11) Process id is different on every call. I am running PHP 5.3.0 on os x 10.6. This site seems to work on 5.2.11 on another Mac. Not really sure where to go next to debug it. I guess it could be an apache setting as much as a php bug or a problem with the code... any suggestions on where to look next?

    Read the article

  • SATA drive not recognized when installing RHEL 5.1 on PowerEdge R410

    - by Rachel
    Here's my setup: Dell R410 with Perc S100 (software) raid controller on an Intel ICH10R chipset The first problem is that the Perc S100 is only supported on windows. I'm trying to install RHEL 5.1. It boots from the cdrom, but later the installer can't see the cdrom or hard drive. Both are connected to the on-board sata controller. The only options in the R410 bios for SATA are ATA or RAID. I don't need raid, I just want a single drive setup.

    Read the article

  • Artefacts during HDV capture

    - by Jakub Konecki
    When I try to capture HDV video stream from a Canon HV20 camera to a Dell Studio 1558 (Intel i7 720qm) laptop running Win 7 Home Premium x64, the image appears with a very annoying noise - it contains block artefacts. Something is wrong with the Fire Wire controller (Ricoh 1304 OHCI host controller, build-in). Tried changing the driver to legacy one to no avail. This does not happen with DV stream. I'm using a Belkin cable. The capture works OK on another machine.

    Read the article

  • Sonicwall Enhanced With One-To-One NAT, Firewall Blocking Everything

    - by Justin
    Hello, just migrated from a Sonicwall TZ180 (Standard) to a Sonicwall TZ200 (Enhanced). Everything is working except the firewall rules are blocking everything. All hosts are online, and being assigned correct ip addresses. I can browse the internet on the hosts. I am using one-to-one NAT translating public ip addresses to private. 64.87.28.98 -> 192.168.1.2 64.87.28.99 -> 192.168.1.3 etc First order of business is to get ping working. My rule is in the new firewall is (FROM WAN to LAN): SOURCE DESTINATION SERVICE ACTION USERS ANY 192.168.1.2-192.168.1.6 PING ALLOW ALL This should be working, but not. I even tried changing the destination to the public ip addresses, but still no luck. SOURCE DESTINATION SERVICE ACTION USERS ANY 64.87.28.98-64.87.28.106 PING ALLOW ALL Any ideas what I am doing wrong?

    Read the article

  • Calling the LWRP from the Exception Handler

    - by Sarah Haskins
    Is it possible to call out to a Provider (LWRP) from a Chef Exception Handler? I think my Provider is out of scope, but I don't know if what I am trying to do is possible? or advisable? Here is my provider code (cookbooks/config/provider/signal.rb): action :failure do Chef::Log.info("Yeah success") end Here is my exception handler code (exception_handler/handlers/exceptionHandler.rb): require 'chef/handler' config_signal "signal" do action :nothing end class Chef class Handler class LogCollector < Chef::Handler notifies :failure, resources(:config_signal => signal) end end end Also, if anyone has a good recommendation for general reading about scope in the context of Chef I'd appreciate it.

    Read the article

  • MD3200i Slow Performance and Queue Depth

    - by Caleb_S
    Read performance on our SAN is slow under certain workloads. When we compare this to some local storage, we find the local storage performing 2x as fast. The SAN performs well with a high Queue Depth, and poorly with a low queue depth. However, the local storage performs well with a low Queue Depth. I'd like to know the reason for this occurring and find out what the specific limiting factor is in this situation. MD3200i iSCSI SAN ($15,000) 6 x 600GB 15k SAS RAID5 6 x 2TB 7.2k NLS RAID5 XCOPY /j Benchmark: (Slow) 15k Array - 71MB/s (Queue Depth 1) 7.2k Array- 71MB/s (Queue Depth 1) Robycopy /MT:32 Benchmark: (Fast) 15k Array - 171MB/s (Queue Depth ~12) 7.2k Array- 128MB/s (Queue Depth ~12) , , Read Performance on a Local controller is fast under the workload the SAN is slow at. , HighPoint 2230 RAID Controller ($600) 4 x 1TB 7.2k SATA RAID5 XCOPY /j Benchmark: 7.2k Array - 145MB/s (Queue Depth 1) (appears to max out the SATA bus)

    Read the article

  • Logon Failure: the target account name is incorrect after making a ghost image of a server

    - by cop1152
    I recently replaced a failing SCSI drive in a Windows 2000 server with an IDE drive. I made an image of the SCSI drive and Ghosted it. The purpose of the machine was to give out DHCP at one location and host a couple of files. When I restarted the machine with the new drive, DHCP appears to be working fine, but I cannot get to any of the shares. Instead, I get the following message when attempting to navigate using Explorer. Logon Failure: the target account name is incorrect It appears that this machine is not communicating with the main domain controller. Changes to user accounts (performed on the domain controller) are not replicated on this machine.

    Read the article

  • How to tell if OpenGL is really working in Ubuntu 10.04

    - by Jonathan
    I have a lenovo S9e running Intel integrated graphics. Here is my lspci output related to the graphics: 00:02.1 Display controller: Intel Corporation Mobile 945GM/GMS/GME, 943/940GML Express Integrated Graphics Controller (rev 03) Subsystem: Lenovo Device 3870 Flags: bus master, fast devsel, latency 0 Memory at f0580000 (32-bit, non-prefetchable) [size=512K] Capabilities: [d0] Power Management version 2 I want to know how I can make sure OpenGL support is running in full on an Ubuntu 10.04 installation. I have a few hints to think that it is not: The "Desktop Effects" will not load Apps such as stardock, when attempting to use OpenGL rendering, will display black boxes instead of transparency In the games Pioneers, the number-tile icons are suspiciously just black circles Windows games running with Wine will only support software rendering, not hardware rendering When I boot into a Knoppix LiveCD, the desktop effects do work, splendidly, meaning compiz detects my computer as capable. My problem with troubleshooting is that Canonical has basically eliminated the conf-file-based mechanism of X11 as far as I can tell, thus making it even harder to ensure graphics modules are loading properly. How do I debug and test OpenGL on m Ubuntu 10.04 installation?

    Read the article

  • Older raid controllers in raid 5 vs. Jbod and SW raid

    - by TEB
    Hi. Im in the fortunate position to have 6 Supermicro older VOD servers with the following config: Supermicro 3U case, 3xPSU Dual Xeon 3ghz P4 class cpu (5 years old.. havnt checked the exact type) 4GB Ram 3ware 9500-8 SATA controller 8 SATA SLOTS and alot of free drives. 2GB FLASH Bootdrive What im curious about is the RAID5 performance on these old beasts in HW mode vs. SW on Linux with the controller set in JBOD mode. Im thinking on using Centos 5.5 or Ubuntu or ZFS RaidZ on Opensolaris. Any tips? or reccomendations ? best regards TEB

    Read the article

  • Ubuntu 10.04 not detecting multiple monitors

    - by razass
    I have 2 graphics cards, the output from the lspci: 01:00.0 VGA compatible controller: ATI Technologies Inc RV770 [Radeon HD 4850] 02:00.0 VGA compatible controller: ATI Technologies Inc RV710 [Radeon HD 4350] I have one monitor connected to the 4850 and 2 connected to the 4350. However when I go into System Preferences Monitors the only monitor shown is the one connected to the 4850. Is there something I need to enable for it to be able to use the other card? How do I get this to work. Thanks.

    Read the article

  • Linux - How to run Firefox with AT command

    - by conualfy
    I try to run a specified command on a desired time. I found at for this, and it seems to work fine if I run: echo "ls -al / > /home/florin/test.txt" | at 4:21am But I want to run a different thing: /usr/bin/firefox -new-tab http://google.ro I tried adapting the first line with my action (running it in terminal opens a new Firefox tab with http://google.ro, so the command is correct), but with at, it does not work: echo "firefox -new-tab http://google.ro" | at 4:23am The task seems to be scheduled, but it does not run. When running the previous line I get the default reply from at: warning: commands will be executed using /bin/sh Should my Firefox command be differently run in sh? Is there a way to do my action with at, or some other way? Thanks a lot!

    Read the article

  • High disk time on sql-server

    - by Patrik
    Hi We have a dedicated sql-server 2008 r2 enterprise edition. The setup is: D: (data files) - stored on local ssd disks (not the same disks as log files) (raid 10) E: (log files) - stored on local ssd disks (not the same disks as data files) (raid 1) F: (transaction log backup) - stored remote on a SAN Today we moved our log files to new disks (from F: to E:). From a shared volume ( F:(SAN)) to dedicated local disks (E:). What then happend was that the "disk time", "avg. transfer time" and "avg disk write queue length" increased on the volume where we have the data files (D:) (not on the volume where the log files are located). The data volume and log volume does not share disks, however they share the same controller card. "Disk idle time" is low for all volumes. One thought is ofcourse that the controller card might be overloaded. But, we need more ideas on where the problem might be.

    Read the article

  • How to configure ASP.NET MVC 3 on IIS 6 (Windows 2003 R2)

    - by Nedcode
    I am getting 403 Directory Listing Denied for the root and 404 for an action that I know should exist. Background: I have build and deployed an ASP.NET MVC 2 applcation a long time ago. Later I upgraded it to MVC 3 and it is still working with not configuration changes. Setting it up on a windows 2003 R2 (Standard) initialy was a pain, but after a couple of days(yes, days) struggling it started working. Now I have to do the same with the same application on a different server (2003 R2 Standard again) on a different network. .Net 4 is installed and allowed ASP.NET MVC 3 is also installed By default IIS is set to use .net 4 I verify aspnet_isapi.dll used in application extension are from version 4.0.30319 .NET asemblies folder. I also added the wildcard mapping to aspnet_isapi.dll and unchecked verify file exists. Under Directory Security in Authentication Methods I have disabled anonymos access and enabled Integrated Windows authentication(same as the one on the server that it works) I have copied the same web.config with the <authentication mode="Windows" /> <authorization> <deny users="?" /> </authorization> I have set Read & Execute, List Folder Contents, and Read for the Networkservice account(under which the app pool is working). Also I have set the same for Network account, IIS_WPG, ASPNET and IUSR_MAchineName. I do not have an EnableExte??nsionlessUrls but even if I create it and set it to true or false it does not help. I also tried http://haacked.com/archive/2010/12/22/asp-net-mvc-3-extensionless-urls-on-iis-6.aspx and it did not help. But I kept getting 403 Directory Listing Denied for the root and 404 for an action that I know should exist. Web Platform installer was then used to re-install and possibly update .net, asp.net etc. I then noticed IIS was reset to default. So I added the wildcard mapping again. No, luck still 403. I exported configuration files from the working server setup and created new default app pool and new default website using those configurations. Still I get 403 Directory Listing Denied for the / and 404 for any action I try.

    Read the article

  • configuring mod_proxy_html properly?

    - by tobinjim
    I have an apache2 web server that handles reverse proxy for Rails3 app running on another machine. The setup works except URLs generated within the webapp aren't getting rewritten by my configuration for mod_proxy_html. The ["Reverse Proxy Scenario"][1] is exactly what I'm trying to do, so I've followed the tutorial as completely as I know how. I've applied or tried answers supplied here on stackoverflow, to no effect. According to the "Reverse Proxy Scenario" you want a number of modules loaded. All those instructions are in my httpd.conf file and when I examine the output from apactectl -t -D DUMP_MODULES all the expected modules show in amongst the listing. My external web server doing the reverse proxy is at www.ourdomain.org and the Rails app is internally available at apphost.local (the server is Mac OS X Server 10.6, the rails app server is Mac OS X 10.6). What's working right now is access to the webapp via the reverse proxy as: http://www.ourdomain.org/apphost/railsappname/controllername/action But none of the javascript files, css files or other assets get loaded, and links internal to the web app come out missing the apphost portion of the URL, as if my rewrite rule is configured incorrectly (so of course I've focused on that and can't seem to get anything to be added or deleted in the process of passing the html in from the apphost and out through the Apache server). For instance, hovering over an action link in the html returned by the web app you'll get: http://www.ourdomain.org/railsappname/controllername/action Here's what my Apache directives look like: LoadModule proxy_html_module /usr/libexec/apache2/mod_proxy_html.so LoadModule xml2enc_module /usr/libexec/apache2/mod_xml2enc.so ProxyHTMLLogVerbose On LogLevel Debug ProxyPass /apphost/ http://apphost.local/ <Location /apphost/> SetOutputFilter INFLATE;proxy-html;DEFLATE ProxyPassReverse / ProxyHTMLExtended On ProxyHTMLURLMap railsappname/ apphost/railsappname/ RequestHeader unset Accept-Encoding </Location> After every change I make to httpd.conf I religiously check apachectl -t just to be sane. I'm definitely not an Apache expert, but all the directives that follow mine seem to not overrule what I'm doing here. But then nothing that I try seems to alter the URLs I see in my browser after hitting the Apache server with a request for my web app. Even if you can't tell what I've done incorrectly, I'd welcome ideas on how to get Apache to help see what it's working on and doing to the html coming from my web app. That's what I understood the ProxyHTMLLogVerbose On and LogLevel Debug to be setting up, but I'm not seeing anything in the log files.

    Read the article

  • Suggestions on providing HA access to an external (fibre) RAID subsystem

    - by user145198
    We are looking at upgrading our storage capacity with an external RAID subsystem that has redundant (2) fibre controllers, each controller has 4 x 8 Gbps fibre ports. I would like to make access to this storage system occur via HA Linux. Ideally I would connect 2 fibre ports from each controller into each Linux server, and then export either NFS or iSCSI via a 10 Gbe interface. I have seen plenty of references to DRBD, however all of those references tend to use block storage that is solely attached to each machine, rather than having a shared block storage device, so I am unsure if DRBD could (or should) be used in this case. Ideas?

    Read the article

  • Where can I find a link to download the SP2 of OES2?

    - by Philippe
    Hi, I have a Netware Novell server with an eDirectory and different objects configured. I implemented an OEServer2 SP1 to emulate a DSfW to manage the eDirectory with AD. I join the domain with the Administrator login and I am logged as the Administrator domain. So far, there are no problems. When I open the MMC window on Windows Server 08 and snap in the "Active Directory Users and Computers" I can see all the OUs and objects presented in the Netware N. server. But, when I select some OUs I can have an error, and when I select other I don’t have this error. Error: “Data from XXXXX is not available from Domain Controller OES2.yyyy.local because: The server is unwilling to process the request. Try again later, or choose another DC by selecting Connect to Domain Controller on the Domain context menu.” With XXXX= OU’s name and yyyy.local= domain name and OES2 server name If somebody can upload this SP or post a link to download it... Thank you for your help!

    Read the article

  • How to add addtional disks to a Windows 2008 KVM based Guest?

    - by taazaa
    I have a Win 2008 KVM based guest VM running on a Ubuntu 10 host. It is a raw image of 22G. I want to add a "data" drive which would show up as "D:\" drive on the guest. I first created a raw image using: qemu-img create -f raw ~/vmdisk2.img 50G Then, tried attaching it using virsh attach-disk. When that did not work, I tried editing the xml file of the VM directly. Both did not seem to work. I would greatly appreciate any help on how to do this and what the best practice is. I want to keep the base image small, so that I can clone it (hopefully) and then attach necessary storage based on the application at hand. Update: The xml of the vm before adding the second drive: <domain type='kvm'> <name>win08e-vm1</name> <uuid>183a4ba0-1c0b-0b04-ad01-aa7c3a4cb390</uuid> <memory>1048576</memory> <currentMemory>1048576</currentMemory> <vcpu>2</vcpu> <os> <type arch='x86_64' machine='pc-0.12'>hvm</type> <boot dev='hd'/> </os> <features> <acpi/> <apic/> <pae/> </features> <clock offset='localtime'/> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>restart</on_crash> <devices> <emulator>/usr/bin/kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='raw'/> <source file='/var/lib/libvirt/images/win08e-vm1.img'/> <target dev='hda' bus='ide'/> <address type='drive' controller='0' bus='0' unit='0'/> </disk> <disk type='file' device='cdrom'> <driver name='qemu' type='raw'/> <source file='/home/taazaa/iso/Win08ER264.iso'/> <target dev='hdc' bus='ide'/> <readonly/> <address type='drive' controller='0' bus='1' unit='0'/> </disk> <controller type='ide' index='0'> <address type='pci' domain='0x0000' bus='0x00' slot='0x01' function='0x1'/> </controller> <interface type='bridge'> <mac address='52:54:00:7f:a7:ae'/> <source bridge='br0'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </interface> <serial type='pty'> <target port='0'/> </serial> <console type='pty'> <target type='serial' port='0'/> </console> <input type='tablet' bus='usb'/> <input type='mouse' bus='ps2'/> <graphics type='vnc' port='-1' autoport='yes' keymap='en-us'/> <video> <model type='vga' vram='9216' heads='1'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x02' function='0x0'/> </video> <memballoon model='virtio'> <address type='pci' domain='0x0000' bus='0x00' slot='0x04' function='0x0'/> </memballoon> </devices> </domain> Thanks!

    Read the article

  • Does mdadm allow to mix sata drives and USB -> sata drives ?

    - by marc
    Welcome, I have question, i have working array md5 of 5 drives. We are running out of space. Server don't have big usage but it have to be online. We can't add another controller. I got idea to buy a USB drive case ? Does mdadm allow to mix array created on sata drives by controller and virtual usb ? (we don't boot from mdadm) But im not sure is this will work ? Is usb drives are configurated before mdadm demon start ? Regards

    Read the article

  • Best technique for reusing a Windows system image across configurations

    - by Martin Wiboe
    We are a small company that provides solutions for ventilation systems. Part of the solution is a "controller" which communicates with the ventilation equipment. These controllers are simply Dell computers that come with our Windows 7 system image on them and sometimes some special hardware. We typically do a batch of 10 controllers at a time. We have been using Norton Ghost to apply the system image, but this process breaks because Dell changes the system configuration often, and our Windows image now does not contain the correct drivers. This is especially a problem when they change the RAID controller. To improve this, I see 2 options: use some kind of virtualization and install a hypervisor on each PC. This would solve the driver problem, but probably cause trouble with our special hardware. use some method of adding the proper drivers to our Windows image in offline mode. I haven't got much experience in either of these approaches. How would you solve our problem?

    Read the article

< Previous Page | 213 214 215 216 217 218 219 220 221 222 223 224  | Next Page >