Search Results

Search found 1600 results on 64 pages for 'exam revision'.

Page 22/64 | < Previous Page | 18 19 20 21 22 23 24 25 26 27 28 29  | Next Page >

  • How to set up raid monitoring on a Adaptec AAC-RAID on a Dell?

    - by pjz
    I've got Debian on a Dell with an Adaptec RAID: AAC0: kernel 4.1-0[7417] AAC0: monitor 4.1-0[7417] AAC0: bios 4.1-0[7417] AAC0: serial 4edf09 scsi2 : aacraid Vendor: CERC Model: DATA 1 Rev: V1.0 Type: Direct-Access ANSI SCSI revision: 02 Vendor: CERC Model: Data 2 Rev: V1.0 Type: Direct-Access ANSI SCSI revision: 02 I've got it set up using the fine afacli tool (ick). Is there a way to get it to email me when there's an error? Do I need to hand-roll a script for this? what's the right version of the afacli tool to use? v4.1 gets SIGABRT and exits after I ask it to 'container list' or 'enclosure list' v2.8's enclosure commands don't work either Do I need to upgrade firmware? to what? from where? how?

    Read the article

  • Using the promote builds plugin to tag subversion repository in jenkins

    - by mark
    We have a task which builds based on data from 4 different SVN repositories. I want to allow QA promote a build, so that the revisions participating in the build are tagged with the build number and some optional label. I have encountered the following problem - the promoted build may not be the most recent build. How do I know the SVN revision of each of the four repositories used during that build? I know that each build has this information in the revision.txt and build.xml files associated with the build, but how does it become available in the context of promotion? Thanks. P.S. Asked here before, but did not get a satisfying answer.

    Read the article

  • "svn up" misses files!

    - by Blastura
    When trying to do an svn up I get the normal At revision XX even though some files are missing, the missing files do show when doing an svn list example: $ svn list > ConditionTest.java > persistence $ ls > persistence $ svn list > ConditionTest.java > persistence/ $ svn up > Is at revision 55 $ ls > persistence The file ConditionTest.java is not added unless manually running svn up ConditionTest.java What is up? Can't I trust svn anymore? Running svn, version 1.6.6 (r40053)

    Read the article

  • Why doesn't Gradle include transitive dependencies in compile / runtime classpath?

    - by Francis Toth
    I'm learning how Gradle works, and I can't understand how it resolves a project transitive dependencies. For now, I have two projects : projectA : which has a couple of dependencies on external libraries projectB : which has only one dependency on projectA No matter how I try, when I build projectB, gradle doesn't include any projectA dependencies (X and Y) in projectB's compile or runtime classpath. I've only managed to make it work by including projectA's dependencies in projectB's build script, which, in my opinion does not make any sense. These dependencies should be automatically attached to projectB. I'm pretty sure I'm missing something but I can't figure out what. I've read about "lib dependencies", but it seems to apply only to local projects like described here, not on external dependencies. Here is the build.gradle I use in the root project (the one that contains both projectA and projectB) : buildscript { repositories { mavenCentral() } dependencies { classpath 'com.android.tools.build:gradle:0.3' } } subprojects { apply plugin: 'java' apply plugin: 'idea' group = 'com.company' repositories { mavenCentral() add(new org.apache.ivy.plugins.resolver.SshResolver()) { name = 'customRepo' addIvyPattern "ssh://.../repository/[organization]/[module]/[revision]/[module].xml" addArtifactPattern "ssh://.../[organization]/[module]/[revision]/[module](-[classifier]).[ext]" } } sourceSets { main { java { srcDir 'src/' } } } idea.module { downloadSources = true } // task that create sources jar task sourceJar(type: Jar) { from sourceSets.main.java classifier 'sources' } // Publishing configuration uploadArchives { repositories { add project.repositories.customRepo } } artifacts { archives(sourceJar) { name "$name-sources" type 'source' builtBy sourceJar } } } This one concerns projectA only : version = '1.0' dependencies { compile 'com.company:X:1.0' compile 'com.company:B:1.0' } And this is the one used by projectB : version = '1.0' dependencies { compile ('com.company:projectA:1.0') { transitive = true } } Thank you in advance for any help, and please, apologize me for my bad English.

    Read the article

  • SATA errors reported during boot: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0

    - by digby280
    I have noticed some error during the Linux boot. They seem to continue to occur after the boot adding lines to the log every few seconds. Once booted this normally does not appear to be causing any problems. However, around 1 in 10 boots results in a kernel panic and the computer has on two or three occasions suddenly rebooted after being powered on for a number of hours. I presume the cause of the reboot is a kernel panic as well. I am running Ubuntu 11.10 and I have had Ubuntu installed on the computer for around a year. I have googled around and not found anything useful. I have provided the kernel log lines and the output of smartctl. Can anyone explain exactly what these errors mean, or better still how to resolve them? Apr 2 16:51:27 dell580 kernel: [ 19.831140] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:27 dell580 kernel: [ 19.934194] tg3 0000:03:00.0: eth0: Link is down Apr 2 16:51:28 dell580 kernel: [ 20.929468] tg3 0000:03:00.0: eth0: Link is up at 100 Mbps, full duplex Apr 2 16:51:28 dell580 kernel: [ 20.929471] tg3 0000:03:00.0: eth0: Flow control is on for TX and on for RX Apr 2 16:51:28 dell580 kernel: [ 20.929727] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready Apr 2 16:51:29 dell580 kernel: [ 21.609381] EXT4-fs (sdb2): re-mounted. Opts: errors=remount-ro,user_xattr,commit=0 Apr 2 16:51:29 dell580 kernel: [ 21.616515] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:29 dell580 kernel: [ 21.616519] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:29 dell580 kernel: [ 21.616525] ata2.00: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 21.934036] ata2.01: hard resetting link Apr 2 16:51:29 dell580 kernel: [ 22.408890] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.408907] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:29 dell580 kernel: [ 22.440934] ata2.00: configured for UDMA/100 Apr 2 16:51:29 dell580 kernel: [ 22.449040] ata2.01: configured for UDMA/133 Apr 2 16:51:29 dell580 kernel: [ 22.449818] ata2: EH complete Apr 2 16:51:33 dell580 kernel: [ 26.122664] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:33 dell580 kernel: [ 26.122670] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:33 dell580 kernel: [ 26.122677] ata2.00: hard resetting link Apr 2 16:51:33 dell580 kernel: [ 26.442684] ata2.01: hard resetting link Apr 2 16:51:34 dell580 kernel: [ 26.925545] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.925561] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:34 dell580 kernel: [ 26.961542] ata2.00: configured for UDMA/100 Apr 2 16:51:34 dell580 kernel: [ 26.969616] ata2.01: configured for UDMA/133 Apr 2 16:51:34 dell580 kernel: [ 26.970400] ata2: EH complete Apr 2 16:51:35 dell580 kernel: [ 28.111180] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:35 dell580 kernel: [ 28.111184] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:35 dell580 kernel: [ 28.111191] ata2.00: hard resetting link Apr 2 16:51:35 dell580 kernel: [ 28.429674] ata2.01: hard resetting link Apr 2 16:51:36 dell580 kernel: [ 28.904557] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.904572] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:36 dell580 kernel: [ 28.936609] ata2.00: configured for UDMA/100 Apr 2 16:51:36 dell580 kernel: [ 28.944692] ata2.01: configured for UDMA/133 Apr 2 16:51:36 dell580 kernel: [ 28.945464] ata2: EH complete Apr 2 16:51:38 dell580 kernel: [ 31.581756] eth0: no IPv6 routers present Apr 2 16:51:38 dell580 kernel: [ 32.103066] ata2.01: exception Emask 0x40 SAct 0x0 SErr 0x80800 action 0x0 Apr 2 16:51:38 dell580 kernel: [ 32.103074] ata2.01: SError: { HostInt 10B8B } Apr 2 16:51:38 dell580 kernel: [ 32.103085] ata2.00: hard resetting link Apr 2 16:51:38 dell580 kernel: [ 32.419669] ata2.01: hard resetting link Apr 2 16:51:39 dell580 kernel: [ 32.894518] ata2.00: SATA link up 1.5 Gbps (SStatus 113 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.894533] ata2.01: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 2 16:51:39 dell580 kernel: [ 32.926536] ata2.00: configured for UDMA/100 Apr 2 16:51:39 dell580 kernel: [ 32.934715] ata2.01: configured for UDMA/133 Apr 2 16:51:39 dell580 kernel: [ 32.935578] ata2: EH complete Here's the output of smartctl for the drive. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.0.0-17-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT Device Model: SAMSUNG HD103UJ Serial Number: S13PJ90QC19706 LU WWN Device Id: 5 0000f0 00b1c7960 Firmware Version: 1AA01113 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3b Local Time is: Mon Apr 2 17:13:48 2012 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 41) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: (11772) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 197) minutes. Conveyance self-test routine recommended polling time: ( 21) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 076 076 011 Pre-fail Always - 7940 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 521 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 642 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 482 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 759 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 073 069 000 Old_age Always - 27 (Min/Max 16/27) 194 Temperature_Celsius 0x0022 073 067 000 Old_age Always - 27 (Min/Max 16/28) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 320028 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 099 099 000 Old_age Always - 1494 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 211 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 211 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 0f 31 63 8f e1 Error: ICRC, ABRT 15 sectors at LBA = 0x018f6331 = 26174257 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 40 62 8f e1 08 00:01:00.460 READ DMA c8 00 20 00 7c 30 e0 08 00:01:00.450 READ DMA c8 00 00 10 49 8f e1 08 00:01:00.440 READ DMA c8 00 e0 20 d0 30 e0 08 00:01:00.420 READ DMA c8 00 00 c0 59 90 e1 08 00:01:00.400 READ DMA Error 210 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 cf e9 cf 66 e0 Error: ICRC, ABRT 207 sectors at LBA = 0x0066cfe9 = 6737897 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 b8 cf 66 e0 08 00:08:29.780 READ DMA c8 00 60 60 c9 18 e0 08 00:08:29.770 READ DMA c8 00 40 20 c9 18 e0 08 00:08:29.770 READ DMA c8 00 20 00 c9 18 e0 08 00:08:29.760 READ DMA c8 00 20 98 cf 66 e0 08 00:08:29.750 READ DMA Error 209 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 2f d1 74 e0 e0 Error: ICRC, ABRT 47 sectors at LBA = 0x00e074d1 = 14709969 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 00 74 e0 e0 08 00:00:30.940 READ DMA c8 00 20 18 36 de e0 08 00:00:30.930 READ DMA c8 00 08 48 f1 dd e0 08 00:00:30.930 READ DMA c8 00 08 a8 f0 dd e0 08 00:00:30.930 READ DMA c8 00 08 90 f0 dd e0 08 00:00:30.930 READ DMA Error 208 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 7f 21 88 9d e0 Error: ICRC, ABRT 127 sectors at LBA = 0x009d8821 = 10324001 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 a0 00 88 9d e0 08 00:00:27.610 READ DMA c8 00 58 a8 e7 9c e0 08 00:00:27.610 READ DMA c8 00 00 28 e6 9c e0 08 00:00:27.610 READ DMA c8 00 00 e0 e4 9c e0 08 00:00:27.610 READ DMA c8 00 00 90 e0 9c e0 08 00:00:27.600 READ DMA Error 207 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 26 6a 6a c3 e0 Error: ABRT at LBA = 0x00c36a6a = 12806762 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- ca 00 00 90 69 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 68 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 50 65 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 d0 64 c3 e0 08 00:29:39.350 WRITE DMA ca 00 40 90 63 c3 e0 08 00:29:39.350 WRITE DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Interrupted (host reset) 90% 638 - # 2 Short offline Interrupted (host reset) 90% 638 - # 3 Extended offline Interrupted (host reset) 90% 638 - # 4 Short offline Interrupted (host reset) 90% 638 - # 5 Extended offline Interrupted (host reset) 90% 638 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • Downloading specific video renditions in WebCenter Content

    - by Kyle Hatlestad
    I recently had a question come up on one of my previous blog articles about downloading a specific video rendition.  When accessing image renditions, you simply need to pass in the 'Rendition=<rendition name>' parameter on the GET_FILE service and it will be returned.  But when you try that with videos, you get the error message, "Unable to download '<Content ID>'. The rendition or attachment '<Rendition Name>' could not be found in the list manifest of the revision with internal revision ID '<dID>'. Through the interface, it exposes the ability to download, but utilizes the Content Basket to bundle one or more videos and download them as a zip.   I had never tried this with videos, but thought they had worked the same way.  Well, it turns out you need to pass in an extra parameter in the case of videos.  So if you pass in parameter of 'AuxRenditionType=media', that will allow the GET_FILE service to download the video (e.g. http://server/cs/idcplg?IdcService=GET_FILE&dID=11012&dDocName=WCCBASE9010812&allowInterrupt=1 &Rendition=QuickTime&AuxRenditionType=media).  And if you haven't seen the David After Dentist video, I'd highly recommend it! 

    Read the article

  • A Virtual Dilemma

    - by antony.reynolds
    Solving a Gotcha with VirtualBox Guest Additions I was just building a new virtual machine based off an existing image that didn’t have the Virtual Box Guest Additions enabled.  The guest additions allow tight integration between the guest OS and the host environment, providing seemless mouse transfer and the ability to take advantage of full video screen size.  The guest additions need to be linked with the kernel which requires the kernel-devel package to be installed.  After installing this package and then trying to add the guest additions it failed, suggesting that I might not have the kernel-devel package that I had installed.  After a little though I finally realized what had happened.  When I grabbed the kernel-devel package I hadn’t checked the version of my kernel.  The kernel-devel I downloaded didn’t match the revision of the kernel I was running!  Hence my problems.  I upgraded the kernel to the same revision as my kernel-devel package and rebooted.  I had installed dkms so I was pleased to see that my VBox Additions successfully built and the mouse and screen now worked as expected. So now you know my embarrassing story for the day :-)

    Read the article

  • Efficient use of Bundling

    - by ACShorten
    One of the discussions I am having with customers and consulting people is about the use of Bundling and its appropriate use. We introduced Bundling post release in the V2.2 code line to allow partners and consultants to build solutions using the Configuration Tools objects such as UI Maps, Service Scripts, Business Objects, Business Services etc and then export and migrate them as solutions. Whilst that was the original intent I have found a few teams using the facility for other data and then complaining about the efficiency or relevance of the tool. Here are a number of guidelines to help optimize the use of Bundling for your implementation: Not all objects can be bundled. Only specific objects in the product can be bundled. These are targetted at Configuration Tools objects and a select group of other objects that are required for these objects. Maintenance Objects with the option "Eligble for Bundling" set to Y (and also contains a Bundling Add BO). Add objects to the Bundle as you complete them - Bundling can have issues with sequencing objects. The best way of combating this is to add objects to the bundle as you complete them. This will help with making sure you sequence the loading of the objects as you are building them in the correct order. Remember Bundling was designed for developers and partners to deliver solutions. If you leave adding objects to a Bundle using the Bundle Export zones then you will have less control of what sequence they are applied and this can cause timing issues. Bundling takes the latest revision  - If you combine Bundling with Revision Control then the Bundling will take the latest release of the object at the time of the export operation. Bundling and Version Control products - If you use a version control tool to control your java code then you can also check in the Bundle to associate a release between code and a bundle. Bundling is quite a powerful feature of the Oracle Utilities Application Framework that allows sales, partners, consultants and customers to package and import their Configuration Tools based solutions.

    Read the article

  • using a wiki for requirements

    - by apollodude217
    Hi, I'm looking into ways of improving requirements management. Currently, we have a Word document published on a Web site. Unfortunately, we cannot (to my knowledge) look at changes from one revision to the next. I would greatly prefer to be able to do so, much like with a wiki or VCS (or both, like the wiki's on bitbucket!). Also, each document describes changes devs are expected to meet by a given deadline. There is no collection of accumulated app features documented anywhere, so it's sometimes hard to distinguish between a bug and a (poorly-designed) feature when trying to make quick fixes to legacy apps. So I had an idea I wanted to get feedback on. What about: Using a wiki so that we can track who changed what when (mostly to even see if any edits were made since the last time one looked). Having one, say, wiki page per product rather than one per deadline, keeping up with all features of the product rather than the changes that should be implemented. This way, I can look at a particular revision of the page to see what the app should do at a given point in time, and I can look at changes to the page since the last release for the requirements to be implemented by the next deadline. Waddayathink?

    Read the article

  • Script/tool to import series of snapshots, each being a new edition, into GIT, populating source tree?

    - by Rob
    I've developed code locally and taken a fairly regular snapshot whenever I reach a significant point in development, e.g. a working build. So I have a long-ish list of about 40 folders, each folder being a snapshot e.g. in ascending date YYYYMMDD order, e.g.:- 20100523 20100614 20100721 20100722 20100809 20100901 20101001 20101003 20101104 20101119 20101203 20101218 20110102 I'm looking for a script to import each of these snapshots into GIT. The end result being that the latest code is the same as the last snapshot, and other editions are accessible and are as numbered. Some other requirements: that the latest edition is not cumulative of the previous snapshots, i.e., files that appeared in older snapshots but which don't appear in later ones (e.g. due to refactoring etc.) should not appear in the latest edition of the code. meanwhile, there should be continuity between files that do persist between snapshots. I would like GIT to know that there are previous editions of these files and not treat them as brand new files within each edition. Some background about my aim: I need to formally revision control this work rather than keep local private snapshot copies. I plan to release this work as open source, so version controlling would be highly recommended I am evaluating some of the current popular version control systems (Subversion and GIT) BUT I definitely need a working solution in GIT as well as subversion. I'm not looking to be persuaded to use one particular tool, I need a solution for each tool I am considering. (I haved posted an answer separately for each tool so separate camps of folks who have expertise in GIT and Subversion will be able to give focused answers on one or the other). The same but separate question for Subversion: Script/tool to import series of snapshots, each being a new revision, into Subversion, populating source tree?

    Read the article

  • How do you structure your shared code so that it is "re-findable" for new developers?

    - by awmckinley
    I started working at my current job about 8 months ago, and its been one of the best experiences I've had as a young programmer. It's a small company, and both my co-developers are brilliant guys. One of the practices that they both have been encouraging is lots of code-reuse. Our code base is mainly C#, and we're using a centralized revision control system. The way the repository is currently structured, there is a single folder in which all shared class libraries are placed (along with unit tests for each library), and our revision control system allows for sharing or linking those libraries out to other projects. What I'm trying to understand at this point is how the current structure of the folder can be made more conducive for finding those libraries again. I've talked to the other developers about this, and they agree that it's gotten a little messy. I find that I am sometimes "reinventing the wheel" because I didn't realize that there was an existing piece of code that solved a particular problem. The issue is complicated further by the fact that we're sharing some code between ASP.NET MVC2, WinForms, and Windows CE projects, and sharing code between applications built against multiple versions of .NET. How do other people approach this? Is the answer in naming the libraries in a certain way or is it preferable to invest in some code-search software? Is the answer in doc comments? Should we be sharing libraries at all or should we simply branch the class libraries for re-use? Thanks for any and all help!

    Read the article

  • SearchServer2008Express Search Webservice

    - by Mike Koerner
    I was working on calling the Search Server 2008 Express search webservice from Powershell.  I kept getting <ResponsePacket xmlns="urn:Microsoft.Search.Response"><Response domain=""><Status>ERROR_NO_RESPONSE</Status><DebugErrorMessage>The search request was unable to connect to the Search Service.</DebugErrorMessage></Response></ResponsePacket>I checked the user authorization, the webservice search status, even the WSDL.  Turns out the URL for the SearchServer2008 search webservice was incorrect.  I was calling $URI= "http://ss2008/_vti_bin/spsearch.asmx?WSDL"and it should have been$URI= "http://ss2008/_vti_bin/search.asmx?WSDL"Here is my sample powershell script:# WSS Documentation http://msdn.microsoft.com/en-us/library/bb862916.aspx$error.clear()#Bad SearchServer2008Express Search URL $URI= "http://ss2008/_vti_bin/spsearch.asmx?WSDL"#Good SearchServer2008Express Search URL $URI= "http://ss2008/_vti_bin/search.asmx?WSDL"$search = New-WebServiceProxy -uri $URI -namespace WSS -class Search -UseDefaultCredential $queryXml = "<QueryPacket Revision='1000'>  <Query >    <SupportedFormats>      <Format revision='1'>urn:Microsoft.Search.Response.Document.Document</Format>    </SupportedFormats>    <Context>      <QueryText language='en-US' type='MSSQLFT'>SELECT Title, Path, Description, Write, Rank, Size FROM Scope() WHERE CONTAINS('Microsoft')</QueryText>      <!--<QueryText language='en-US' type='TEXT'>Microsoft</QueryText> -->    </Context>  </Query></QueryPacket>" $statusResponse = $search.Status()write-host '$statusResponse:'  $statusResponse $GetPortalSearchInfo = $search.GetPortalSearchInfo()write-host '$GetPortalSearchInfo:'  $GetPortalSearchInfo $queryResult = $search.Query($queryXml)write-host '$queryResult:'  $queryResult

    Read the article

  • Tip: Keeping the ADF Mobile PDF Guide up to date

    - by Chris Muir
    This is a little tip for customers using Oracle's ADF Mobile. If you're like me, it's possible you don't rely on the online HTML version of the Mobile Developer's Guide for ADF, but rather download a PDF version of the file to use locally (look to the "PDF" link to the top right of the guide).  For me the convenience of the PDF is it's faster, I can search the whole document easily, I can split read the document across two pages on my home monitor, if I lose my internet connection the document is still available, and it's easy to read on my iPad (especially on long haul flights to the US across the Pacific where there is no internet connection!). The trigger point for me to download the Oracle PDF documentation has always been on a new point release of JDeveloper.  However in the case of ADF Mobile, as an extension to JDeveloper it is releasing at a much faster and independent schedule to JDeveloper and this includes updates to the documentation. As such the 11.1.2.4.0 ADF Mobile PDF guide you have locally might be out of date and you should take the opportunity to download the latest version.  This is also particularly important for ADF Mobile as not only are many new features being added for each release and included in the new documentation, but the guide is under rapid improvement to clarify much of what has been written to date.  Our documentation teams are super responsive to suggestions on how to improve the guides and this often shows per point release. How do you tell you've the latest guide? Look to the document part number which right now is "E24475-03".  This is a unique ID per release for the document, the first part being the document number, and the part after the dash the revision number.  If the website document number has a higher revision number, time to download a new up to date PDF. One last thing to share, you can follow the ADF Mobile guide document manager Brian Duffield on Twitter to keep abreast of updates. Image courtesy of Stuart Miles / FreeDigitalPhotos.net

    Read the article

  • Bluetooth mouse no longer paired after resuming from suspend since upgrading to 13.10

    - by Korakys
    Since upgrading to 13.10 from 13.04 my mouse no longer connects via bluetooth. In settings it states that the mouse is not paired. Restarting bluetooth with sudo /etc/init.d/bluetooth restart does not help. Restarting the computer does fix the problem if bluetooth is restarted also with the previously mentioned command, but this is not ideal. The mouse worked fine prior to updating to 13.10. The computer is a ThinkPad X230 with a Broadcom 'BCM20702A0' bluetooth module (I think). When it is not working hciconfig hci0 -a returns: hci0: Type: BR/EDR Bus: USB BD Address: C0:18:85:DB:F3:D1 ACL MTU: 1021:8 SCO MTU: 64:1 UP RUNNING PSCAN RX bytes:766129 acl:49888 sco:0 events:2233 errors:0 TX bytes:5953 acl:240 sco:0 commands:274 errors:0 Features: 0xbf 0xfe 0xcf 0xfe 0xdb 0xff 0x7b 0x87 Packet type: DM1 DM3 DM5 DH1 DH3 DH5 HV1 HV2 HV3 Link policy: RSWITCH SNIFF Link mode: SLAVE ACCEPT Name: 'BCM20702A' Class: 0x6e0100 Service Classes: Networking, Rendering, Capturing, Audio, Telephony Device Class: Computer, Uncategorized HCI Version: 4.0 (0x6) Revision: 0x1000 LMP Version: 4.0 (0x6) Subversion: 0x220e Manufacturer: Broadcom Corporation (15) When it is working hciconfig hci0 -a returns: hci0: Type: BR/EDR Bus: USB BD Address: C0:18:85:DB:F3:D1 ACL MTU: 1021:8 SCO MTU: 64:1 UP RUNNING PSCAN RX bytes:253334 acl:16391 sco:0 events:842 errors:0 TX bytes:2519 acl:65 sco:0 commands:84 errors:0 Features: 0xbf 0xfe 0xcf 0xfe 0xdb 0xff 0x7b 0x87 Packet type: DM1 DM3 DM5 DH1 DH3 DH5 HV1 HV2 HV3 Link policy: RSWITCH SNIFF Link mode: SLAVE ACCEPT Name: 'ubuntu-0' Class: 0x6e0100 Service Classes: Networking, Rendering, Capturing, Audio, Telephony Device Class: Computer, Uncategorized HCI Version: 4.0 (0x6) Revision: 0x1000 LMP Version: 4.0 (0x6) Subversion: 0x220e Manufacturer: Broadcom Corporation (15) I am a relative novice with linux so don't ask me compile anything please, but I can use google.

    Read the article

  • Internal Libraries (Subversion Externals, 'library' branch, or just another folder)

    - by Ntsc
    Currently working on multiple projects that need to share internal libraries. The internal libraries are updated continually. Currently only 1 project needs to be stable but soon we will need to have both projects stable at any given time. What is the best way to SVN internal libraries? Currently we are using the 'just another folder' like so... trunk\project1 trunk\project2 trunk\libs It causes a major headache when a shared library is updated for project1 and project2 is now dead until the parts that use the library are updated. So after doing some research on SVN externals I thought of this... trunk\project1\libs (external to trunk\libs @ some revision) trunk\project2\libs (external to trunk\libs @ different revision) trunk\libs\ I'm a little worried about how externals work with commits and not making library commits so complicated that I am the only one capable of doing it (mostly worried about branches with externals as we use them extensively). On top of that we have multiple programming languages within each project some of which don't support per-project library directories (at least not easily) so we would need to check out on a per project basis instead of checking out the trunk. There is also the 'vendor' style branching of libraries but it has the same problem as above where the library would have to be a sub folder of each project and is maybe a little to complicated for how little projects we have. Any insight would be nice. I've spent quite a bit of time reading the Subversion book and feeling like I'm getting no where.

    Read the article

  • ?????Exadata????

    - by Liu Maclean(???)
    ??check Exadata Image & OS versions , GI & DB patches sundiag exacheck cellserv ==> imageinfo dbhost ==> /usr/local/bin/imagehistory Also check the version of the switch. Login to Switch and execute the following command [root@myswitch-1 sbin]# version [root@dmorlsw-ib2 sbin]# cd /usr/local/bin [root@dmorlsw-ib2 bin]# ls -lrt version -rwxr-xr-x 1 root root 20356 Apr 4 2011 version Output will look as below. [root@dmorlsw-ib2 ~]# version SUN DCS 36p version: 1.3.3-2 Build time: Apr 4 2011 11:15:19 SP board info: Manufacturing Date: 2009.05.05 Serial Number: "NCD3X0178" Hardware Revision: 0x0006 Firmware Revision: 0x0102 BIOS version: NOW1R112 BIOS date: 04/24/2009 ib8# cat /sys/class/infiniband/is4_0/fw_ver 7.2.300 ib8 # cat /sys/class/dmi/id/bios_version NOW1R112 ib8 # nm2version NM2-36p version: 1.0.1-1 Build time: Sep 14 2009 12:52:51 ComExpress info: Manufacturing Date: 2009.08.19 Serial Number: Hardware Revision: 0x0006 Firmware Revision: 0x0102 { case `uname` in Linux ) ILOM="/usr/bin/ipmitool sunoem cli" ;; SunOS ) ILOM="/opt/ipmitool/bin/ipmitool sunoem cli" ;; esac ; ImageInfo="/opt/oracle.cellos/imageinfo" ; uname -srm ; head -1 /etc/*release ; uptime | cut -d, -f1 ; $ILOM "show /SP system_description system_identifier" | grep = ; $ImageInfo -activated -node -status -ver | grep -v ^$ ; } | tee /tmp/ExaInfo.log $GRID_HOME/OPatch/opatch lsinv -all -oh $GRID_HOME | tee /tmp/OPatchInv.log $ORACLE_HOME/OPatch/opatch lsinv -all | tee -a /tmp/OPatchInv.log cat /tmp/ExaInfo.log Linux 2.6.18-128.1.16.0.1.el5 x86_64 ==> /etc/enterprise-release <== Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) ==> /etc/redhat-release <== Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) 20:37:56 up 458 days system_description = SUN FIRE X4170 SERVER, ILOM v3.0.6.10.b, r52264 system_identifier = Sun Oracle Database Machine Active image version: 11.2.1.2.3 Active image activated: XXXX-XX-XX 12:27:12 +0800 Active image status: success Active node type: COMPUTE Inactive image version: undefined FileName: OPatchInv.log ---------------- ... Oracle Home       : /u01/app/11.2.0/grid Central Inventory : /u01/app/oraInventory   from           : /etc/oraInst.loc OPatch version    : 11.2.0.1.2 OUI version       : 11.2.0.1.0 OUI location      : /u01/app/11.2.0/grid/oui ... -------------------------------------------------------------------------------- List of Oracle Homes:   Name                                       Location   Ora11g_gridinfrahome1         /u01/app/11.2.0/grid   OraDb11g_home1                  /u01/app/oracle/product/11.2.0/dbhome_1 -------------------------------------------------------------------------------- Installed Top-level Products (1): Oracle Grid Infrastructure                                           11.2.0.1.0 ... Interim patches (2) : Patch  9524394      : applied on Thu Jun 03 20:46:05 CST 2010 ... {TRACKING BUG FOR 11.2.0.1 DB MACHINE BUNDLE PATCH 3} Patch  9455587      : applied on Fri Apr 02 18:27:47 CST 2010 ... {MERGE REQUEST ON TOP OF 11.2.0.1.0 FOR BUGS 8483425 8667622 8702731 8730804} Rac system comprising of multiple nodes  Local node = dbserv01  Remote node = dbserv02  Remote node = dbserv03  Remote node = dbserv04 -------------------------------------------------------------------------------- OPatch succeeded. ... Oracle Home       : /u01/app/oracle/product/11.2.0/dbhome_1 ... Oracle Database 11g                                                  11.2.0.1.0 ... Interim patches (5) : Patch  8888434      : applied on Sat Jan 08 00:27:33 CST 2011 ... {AIX-ASM-CF: LMHB TERMINATE INSTANCE WHEN OFFLINE ONE FAILGROUP IN ASM DG} Patch  8730312      : applied on Thu Jun 03 21:30:03 CST 2010 ... {FWD MERGE FOR BASE BUG 8715387 FOR 12G} Patch  9502717      : applied on Thu Jun 03 21:25:54 CST 2010 ... {LMS HIT ORA-600 [KJBLDRMNEXTPKEY:SEEN] AND CRASHED THE INSTANCE} { + same 2 as GI above} ?? cell server Cache Policy cell08# MegaCli64 -LDInfo -Lall -aALL | grep 'Current Cache Policy' Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU cell09# MegaCli64 -LDInfo -Lall -aALL | grep 'Current Cache Policy' Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Cache policy is in WB Would recommend proactive  battery repalcement. Example : a. /opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp  -Cache -LALL -aALL ####( Will list the cache policy) b. /opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp  -WB  -LALL -aALL ####( Will try to change teh policy from xx to WB)     So policy Change to WB will not come into effect immediately     Set Write Policy to WriteBack on Adapter 0, VD 0 (target id: 0) success     Battery capacity is below the threshold value ??cell BBU??????: cell08# /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -a0 BBU status for Adapter: 0 BatteryType: iBBU Voltage: 4061 mV Current: 0 mA Temperature: 36 C BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : No Learn Cycle Active : No Learn Cycle Status : OK Learn Cycle Timeout : No I2c Errors Detected : No Battery Pack Missing : No Battery Replacement required : No Remaining Capacity Low : Yes Periodic Learn Required : No Battery state: GasGuageStatus: Fully Discharged : No Fully Charged : Yes Discharging : Yes Initialized : Yes Remaining Time Alarm : No Remaining Capacity Alarm: No Discharge Terminated : No Over Temperature : No Charging Terminated : No Over Charged : No Relative State of Charge: 99 % Charger System State: 49168 Charger System Ctrl: 0 Charging current: 0 mA Absolute state of charge: 21 % Max Error: 2 % Exit Code: 0x00 ????BBU ??: dcli -g ~/cell_group -l root -t '{ uname -srm ; head -1 /etc/*release ; uptime | cut -d, -f1 ; imagehistory ; ipmitool sunoem cli "show /SP system_description system_identifier" | grep = ; ipmitool sunoem cli "show /SP/policy FLASH_ACCELERATOR_CARD_INSTALLED /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -a0 | egrep -i 'BBU|Battery|Charge:|Fully|Low|Learn' ; }' | tee /tmp/ExaInfo.log Target cells: ['cellserv01', 'cellserv02', 'cellserv03', 'cellserv04', 'cellserv05', 'cellserv06', 'cellserv07'] cellserv01: Linux 2.6.18-128.1.16.0.1.el5 x86_64 cellserv01: ==> /etc/enterprise-release <== cellserv01: Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) cellserv01: cellserv01: ==> /etc/redhat-release <== cellserv01: Enterprise Linux Enterprise Linux Server release 5.3 (Carthage) cellserv01: 01:17:39 up 635 days cellserv01: Version : 11.2.1.2.1 cellserv01: Image activation date : 2011-03-25 11:59:34 -0800 cellserv01: Imaging mode : fresh cellserv01: Imaging status : success cellserv01: cellserv01: Version : 11.2.1.2.3 cellserv01: Image activation date : 2011-04-13 12:15:46 +0800 cellserv01: Imaging mode : patch cellserv01: Imaging status : success cellserv01: cellserv01: Version : 11.2.1.2.6 cellserv01: Image activation date : 2011-05-27 23:08:22 +0800 cellserv01: Imaging mode : patch cellserv01: Imaging status : success cellserv01: cellserv01: system_description = SUN FIRE X4275 SERVER, ILOM v3.0.6.10.b, r52264 cellserv01: system_identifier = Sun Oracle Database Machine cellserv01: Connected. Use ^D to exit. cellserv01: -> show /SP/policy FLASH_ACCELERATOR_CARD_INSTALLED cellserv01: show: No matching properties found. cellserv01: cellserv01: -> Session closed cellserv01: Disconnected cellserv01: BBU status for Adapter: 0 cellserv01: BatteryType: iBBU cellserv01: BBU Firmware Status: cellserv01: Learn Cycle Requested : No cellserv01: Learn Cycle Active : No cellserv01: Learn Cycle Status : OK cellserv01: Learn Cycle Timeout : No cellserv01: Battery Pack Missing : No cellserv01: Battery Replacement required : No cellserv01: Remaining Capacity Low : Yes cellserv01: Periodic Learn Required : No cellserv01: Battery state: cellserv01: Fully Discharged : No cellserv01: Fully Charged : Yes cellserv01: Relative State of Charge: 99 % cellserv01: Absolute state of charge: 21 % dcli -l root -g /root/all_group '/opt/MegaRAID/MegAaCli/MegaCli64 -AdpBbuCmd -a0' > BBU.out check ipmi: dcli -g ~/cell_group -l root -t '{ > ipmitool sunoem cli "show /SP/policy FLASH_ACCELERATOR_CARD_INSTALLED" | grep = ; MegaCli64 -LDInfo -Lall -aALL | grep 'Current Cache Policy' ; }' | tee /tmp/ExaCells.log

    Read the article

  • Sef-packed training kit practice tests

    - by Costa
    Hi I have a book called .Net framework 2.0 application development foundation, self-packed training kit by Tony Northup and Shawn wildermuth. the book CD contains practice tests, Can I rely on this CD to take the exam, or it will be just like the book itself, a wast of money? someone rely on it and success? I am not talking about memorizing or cheating the exam I am talking about studying and practice it. Also When I visit MS website they did not determine the number of questions, type of questions, or the time, someone have this info? Thanks

    Read the article

  • What's the difference between the 'DES' class and The 'DESCryptoServiceProvider' class?

    - by IbrarMumtaz
    All I can make out is that one of them is the BC for all 'DES' algorithms to be derived from and the later is a wrapper for the Cryptographic service provider implementation of the DES algorithm. The reason why I ask is that I am going over .Net Security and the MS official training book simply refers to the DES class but the another official MS book refers to the DESCrypto' class. What's the difference between these two? When would you use either of them? What do I need to know as far as the 70-536 exam is concerned. I am asking my question from an educational P.O.V as far as the 70-536 exam is concerned. Thanks In Advance. Ibrar

    Read the article

  • Minimum vs Minimal vertex covers

    - by panicked
    I am studying for an exam and one of the sample questions is as follows: Vertex cover: a vertex cover in a graph is a set of vertices such that each edge has at least one of its two end points in this set. Minimum vertex cover: a MINIMUM vertex cover in a graph is a vertex cover that has the smallest number of vertices among all possible vertex covers. Minimal vertex cover a MINIMAL vertex cover in a graph is a vertex cover that does not contain another vertex cover (deleting any vertex from the set would create a set of vertices that is not a vertex cover) Question: A minimal vertex cover isn't always a minimum vertex cover. Demonstrate this with a simple example. Can anyone get their head around this? I am failing to see the distinction between the two. More importantly, I'm having a hard time visualizing it. I seriously hope he's not gonna ask odd questions like this one on the exam!

    Read the article

  • Exception Class: When to Derive from it, In C# (.Net)?

    - by IbrarMumtaz
    I am continuing with my exam revision. I have come across the usage of the Base Exception class and I have seen it on exam papers also. My question is when do you derive from the Base Exception class? I am of the impression if you want a custom class to throw an exception with more meaningful information, then you can create a custom exception class that contains the exact data that is representative of how your custom class is used and what scenario it is designed to be used for? Why can't my custom exception class derive from 'ApplicationException' or 'SecurityException' or the base 'Exception' class? I am of the impression that I should derive from the base Exception class and not the previous two. My question second is, when would you derive from the other two??? Are there any clear-cut distinctions as to when you would derive from either one of these three? Assuming there are no others I have I have missed out? Thanks, Ibrar

    Read the article

  • suggestions for someone studying for java certification

    - by newguy
    I have been working with java (J2EE) for about 4 years. I have been putting off the certification for a while now. I bought the exam last year and still have not taken the exam. it expires in june so I am going to give it a shot. I know certifications don't get jobs but interviews but where I work...certification will put a 'stamp' on my resume and I think it'll popout in the eyes of the management. Anyways, I am going for JAVA 6. Can someone suggest some good mock exams that are kind of new and relevant. I came across this link but most of these exams are fairly old. I am using kathy Sierra's book for studying. Any other resources/pointers?

    Read the article

  • JVM specification and Java compiler code useful for SCJP preparation ?

    - by BenoitParis
    I'm preparing the SCJP exam with the almost official study book ("SCJP Sun Certified Programmer for Java 6 Exam 310-065") I understand that Java programming is writting code that fulfills a certain high-level contract; So that Java can stay platform-independent. However, I have trouble understanding and remembering things when it comes to highly specific SCJP items (and they are numerous) The book stays high-level and does not provide examples of how one compiler would handle things. This is the same thing for runtime issues (JVM level): things are too much abstract for me. Rules often seems arbitrary and therefore, with no well defined purpose, are difficult to remember. Or maybe it's that sometimes I just don't get the underlying purpose. And here is the question: Would a JVM specification and/or some java compiler code help in preparing the SCJP? Have you had the need for such material or is the book sufficient enough? Also, please share the resources you used, apart from the book.

    Read the article

  • JPA 2.0 Eclipse Link ... Composite primary keys

    - by Parhs
    I have two entities(actually more but it doenst matter) Exam and Exam_Normals Its a oneToMany relationship... The problem is that i need a primary key for Exams_Normals PK (Exam_ID Item) Item should be 1 2 3 4 5 etc.... But cant achieve it getting errors An alternative would be to: I cound use an IDENTITY and a ManyToOne relationship at Exam_Normals but that should be like PK(Exam_Normals_ID) and a reference to Exam and an extra collumn Item to keep an order.. SO 3 collumns But to avoid the alternative tried I tried with @IdClass and got errors Tried @EmbeddedID everything nothing works Any idea??

    Read the article

  • Best resources to prepare for the "Spring Framework Certification"

    - by Johan Pelgrim
    Hi there I want to do the Spring Framework Certification (2.5), but there aren't many good resources to prepare for the exam. For the Sun certifications there are a lot of books and trainers (Enthuware / Whizlabs) but not for the Spring certification. Has somebody done the 2.5 exam already? What was your first impression? How did you prepare? What resources did you have and which are sufficient. Thanks in advance for your answers!

    Read the article

< Previous Page | 18 19 20 21 22 23 24 25 26 27 28 29  | Next Page >