Search Results

Search found 11073 results on 443 pages for 'higher kinded types'.

Page 233/443 | < Previous Page | 229 230 231 232 233 234 235 236 237 238 239 240  | Next Page >

  • sbs-server with 2 nics and 2 connections to the internet with different providers not working as it

    - by erik-van-gorp
    We have the following configuration : A sbs-2003 server in a domain (mydomain.com) with 2 network cards, each connected to a different network (provider), with different gateways, one for web and one for mail and clients. (we do this because the bandwitdh we get from our providers is too small to handle all the mail(+spam) traffic and webservices, so we took 2 providers) DNS is as follows : www.mydomain.com 1.2.3.4 mail.mydomain.com 5.6.7.8 NIC 1(192.168.1.3) is connected to to the internet through a firewall at 192.168.1.1, having wan address 1.2.3.4 NIC 2(10.0.0.3) is connected to to the internet through a firewall at 10.0.0.1, having wan address 5.6.7.8 Both nics have their default gateway installed at their corresponding routers. Also the metrics are set equal. (i know this isn't a supported config, but it works more or less). In this configuration i can use RDP on both wan adresses, and telnet to port 25 works as well on both. The issue now is that since a few weeks , we get regular disconnections, and website hickups(timeouts), several per hour. If we set one router to a higher metric, that route no longer works. In short, I want the mails to route through NIC2 and the web through NIC1. Any better configuration (without installing a second mail server) ?

    Read the article

  • Short, intermittent USB port timeouts

    - by jacobsee
    I have a data acquisition application controlled by a Windows PC. I am using an Intel Desktop Board DH67CL motherboard. This has 6 USB2 ports along with 2 of the new blue USB3 ports. The DAQ instrument connects via USB to the computer. Roughly once every day or two there is a short communication glitch with the USB that causes the instrument to disconnect briefly and then reconnect. This is logged so I know whenever it happens. Occasionally it will cause the data acquisition to stop. I've verified that the glitches will go away if I use the USB3 ports, or if I use a PCI add-on card with USB ports. So it seems that there is something going on with these built-in USB2 ports on this motherboard. I haven't yet had a chance to test with other motherboards. My question: what could be causing these glitches and how to get rid of them for this board, or is there a better motherboard to use? We have standardized on the DH67CL because it's inexpensive, has 3 PCI slots that we need, and is readily available. We don't need the power of higher-end server boards but reliability is important. Thanks. Update: This problem has been reproduced many times on different hardware, though we always use the same model of motherboard (DH67CL) and power supply (Antec EA-430D). I don't think the power requirements are very high but will check on that.

    Read the article

  • explanation of RAM specs, and what do I need for a Gaming rig

    - by ewok
    I am looking into upgrading my custom built PC's RAM. I use the machine mostly for gaming, but I don't really know a ton about RAM, so I wanted to ask a few questions. The research I've done tells me there is a negligible increase in speed for anything above 1600 MHz. is this true or is it worth the extra money to go higher? Other than drawing more power from the PSU, is there any real difference in performance with different voltages (1.5V vs 1.65V)? most of the kits I've found in the 2x4 1600 range have a CAS latency of 9 and timing of 9-9-9-24. For a significant increase in price (usually about 1.5x), I can get either 8 or 7 and lower timing. Is it worth the cost? What I am looking for here is someone to give a good explanation of what the different specs represent, and how that relates to the performance of the machine. Specifically, I'm looking for what specs I need to focus on for a good gaming rig. I am NOT looking for a "buy this, it's the best RAM" without an explanation of why. The information will be much more valuable as it will allow me to make my own informed decision. As they say, give a man a fish, he'll eat for a day. teach a man to fish, and he'll eat for the rest of his life.

    Read the article

  • data transfer rate anomaly (internet)

    - by Nrew
    I tested my internet speed at speedtest.net. And go the result. .42Mbps Download and .21 Upload rate. My classmate got the same download speed of .42Mbps but has .87Mbps upload rate. Does upload rate affect the transfer rate?Because even though we got the same download speed. His transfer rate is about 100kbps downloading a movie from a torrent. And mine is only about 47kbps. Also the same torrent. And even direct download its always 47kbps. Is it possible to tweak something in order to have higher transfer rates. Other details: Were also both using the same ISP. The same slow ISP. And it seems that he's getting the most out of his connection even if his plan is lower than mine. I just don't know why I'm a loser at this. And when I try to complain to the ISP. They say that I'm getting the minimum speed and its okay. That really sucks. And I'm not using any router, so is he. The computer is directly connected to the internet using the modem provided by the ISP.

    Read the article

  • Is there an application to log component temperatures to file?

    - by MrVimes
    I purchased a computer a month or two ago (core i7, 24gb ram, geforce gtx 590, windows 7 ultimate). Within the last week it began to bluescreen regularly. I tried lots of things (check hds, check memory, reinstall windows etc..) but it still bluescreened. At the time my temps were as follows... CPU - aprox 40/50c. GPU - arpox 60 idle, aprox 90 during heavy use. HDDs - aprox 55c after the PC had been on a while. I thought the 55c was ok, but I have since realized it was probably too high and may have been the direct cause of the bluescreening. I've installed a spare fan I had in the front of the PC blowing air in, (so there's airflow from front to back) Since then, obviously, all my temps are down. Especially the HDDs - three of them reach 30c and one has been up to 47c (it is some distance away from the airflow, in one of the 5.25inch drive bays) I haven't had the PC on for as long as it would normally take to bluescreen yet, but If it does I want to know what all the temps were right before the bluescreen. I have tried Everest but it only shows me realtime temps or gives me the ability to create one-off reports. I want something that can record all the temps to a file at 30 seconds intervals. If the computer bluescreens I can load it up again and check the last entry in the file. Side question: Am I right in thinking 55c was far too hot for a HDD? (It might have got higher than that before the bluescreens.. I don't know) Another side question: Is 47c too high? This is actually why I am asking the main question - I am concerned that this one drive that isn't getting the benefit of the extra fan may still cause the computer to bluescreen.

    Read the article

  • Platform to allow users to suggest and vote for ideas

    - by Simon
    I head up a support team for a software product. I am in the process of setting up a blog (Wordpress.org), a forum (PHPBB or maybe Vanilla), a means to view bugs (probably expose Jira), but would also like to allow our customers to suggest enhancement requests. Currently we have this as a 'contact form' via the blog, which feeds into a dedicated inbox, which the product manager reviews and may include some of these ideas into the product. However, I would like to give the clients more power/visibility over this. Have a look at ideas.arcgis.com. There are plenty of other similar sites as well. Users can suggest new ideas Other users can vote these ideas up or down (similar to Stack Exchange sites) Ideas that are voted highly will be given a higher priority over lower ones. We can report back on the # of ideas we implement, and potentially reject ideas with reasoning. Has anyone seen any platforms (ideally free) which would replicate something similar to this? I was half thinking of embedding Vanilla within a wordpress page, but need to look into it more.

    Read the article

  • What should the memory configuration be?

    - by AngryHacker
    We have a server (ProLiant DL585 G1 by HP), which hosts Windows 2003 x64 R2 with SQL Server 2005 x64 and a host of other apps. It currently has 6GB of RAM. We are currently very memory constrained and it's clear that we need to get more memory. 8GB will probably do the trick, however, we are not sure as to what memory configuration will give us the biggest performance buck. Currently all 8 memory slots are filled (4 slots have 1GB chip, while the other 4 slots have 512MB chips). Should we throw the 512MB sticks away and just replace them all with 1GB sticks? If we decided to go with a higher memory configuration (e.g. 10GB or 12GB or 16GB), is it advisable to keep all the sticks of the same size or it does not matter? I was once told that interleaved memory requires (for better performance) that memory should be in multiples (e.g. 2 or 4 or 8 or 16, etc...). I am not even sure that the server has an interleaved configuration (and don't know how to find out), but is this true? Thanks.

    Read the article

  • PC dies when running at 100% CPU

    - by user155631
    I recently wrote some Java code to generate images of the Mandelbrot set (fractal). I made use of the new Fork/Join facility in Java 7 to run separate threads on all four cores (2 real, 2 virtual)simultaneously, using a large number of iterations for greater accuracy. The problem is, the process runs fine for about a minute, and then it's as if someone has pulled the plug and the PC just dies. I thought it must be the CPUs overheating, so I ran Real Temp to monitor the temperature. It's an Intel i3 processor. I can see the temperature creeping up to 70 degrees, and then it seems to level off there and run for about another 30 seconds before dying. According to Real Temp, there's still a gap of 35 degrees between the actual temperature and TJ max. I also tried disabling "CPU TM function" in the BIOS, but the problem still occurs. A colleague suggested that it might be a power supply problem, so I borrowed a more powerful PSU (can't remember what wattage it was, but it's higher than mine which is 500W). The exact same thing still happens though. Is anyone able to suggest what the problem might be, or what I can try next?

    Read the article

  • using i7 "gamer" cpu in a HPC cluster

    - by user1219721
    I'm running WRF weather model. That's a ram intensive, highly parallel application. I need to build a HPC cluster for that. I use 10GB infiniband interconnect. WRF doesn't depends of core count, but on memory bandwidth. That's why a core i7 3820 or 3930K performs better than high-grade xeons E5-2600 or E7 Seems like universities uses xeon E5-2670 for WRF. It costs about $1500. Spec2006 fp_rates WRF bench shows $580 i7 3930K performs the same with 1600MHz RAM. What's interesting is that i7 can handle up to 2400MHz ram, doing a great performance increase for WRF. Then it really outperforms the xeon. Power comsumption is a bit higher, but still less than 20€ a year. Even including additional part I'll need (PSU, infiniband, case), the i7 way is still 700 €/cpu cheaper than Xeon. So, is it ok to use "gamer" hardware in a HPC cluster ? or should I do it pro with xeon ? (This is not a critical application. I can handle downtime. I think I don't need ECC?)

    Read the article

  • Redirecting or routing all traffic to OpenVPN on a Mac OS X client

    - by sdr56p
    I have configured an OpenVPN (2.2.1) server on an Ubuntu virtual machine in the Amazon elastic compute cloud. The server is up and running. I have installed OpenVPN (2.2.1) on a Mac OS X (10.8.2) client and I am using the openvpn2 binary to connect (in opposition to other clients like Tunnelblick or Viscosity). I can connect with the client and successfully ping or ssh the server through the tunnel. However, I can't redirect all internet traffic through the VPN even if I use the push "redirect-gateway def1 bypass-dhcp" option in the server.conf configurations. When I connect to the server with these configurations, I get a successful connection, but then an infinite series of error messages: "write UDPv4: No route to host (code=65)". Traffic routing seems to be compromised because I am not able to access anything anymore, not even the OpenVPN server (by pinging 10.8.0.1 for instance). This is beyond me. I am finding little help on the web and don't know what to try next. I don't think it is a problem of forwarding the traffic on the server since, first, I have also took care of that and, second, I can't even ping the VPN server locally through the tunnel (or ping anything at all for that matter). Thank you for your help. Here is the server.conf. file: port 1194 proto udp dev tun ca ca.crt cert ec2-server.crt key ec2-server.key # This file should be kept secret dh dh1024.pem server 10.8.0.0 255.255.255.0 ifconfig-pool-persist ipp.txt push "redirect-gateway def1 bypass-dhcp" client-to-client keepalive 10 120 comp-lzo persist-key persist-tun status openvpn-status.log verb 3 And the client.conf file: client dev tun proto udp remote servername.com 1194 resolv-retry infinite nobind persist-key persist-tun ca ca.crt cert Toto5.crt key Toto5.key ns-cert-type server comp-lzo verb 3 Here is the connection log with the error messages: $ sudo openvpn2 --config client.conf Wed Mar 13 22:58:22 2013 OpenVPN 2.2.1 x86_64-apple-darwin12.2.0 [SSL] [LZO2] [eurephia] built on Mar 4 2013 Wed Mar 13 22:58:22 2013 NOTE: OpenVPN 2.1 requires '--script-security 2' or higher to call user-defined scripts or executables Wed Mar 13 22:58:22 2013 LZO compression initialized Wed Mar 13 22:58:22 2013 Control Channel MTU parms [ L:1542 D:138 EF:38 EB:0 ET:0 EL:0 ] Wed Mar 13 22:58:22 2013 Socket Buffers: R=[196724->65536] S=[9216->65536] Wed Mar 13 22:58:22 2013 Data Channel MTU parms [ L:1542 D:1450 EF:42 EB:135 ET:0 EL:0 AF:3/1 ] Wed Mar 13 22:58:22 2013 Local Options hash (VER=V4): '41690919' Wed Mar 13 22:58:22 2013 Expected Remote Options hash (VER=V4): '530fdded' Wed Mar 13 22:58:22 2013 UDPv4 link local: [undef] Wed Mar 13 22:58:22 2013 UDPv4 link remote: 54.234.43.171:1194 Wed Mar 13 22:58:22 2013 TLS: Initial packet from 54.234.43.171:1194, sid=ffbaf343 d0c1a266 Wed Mar 13 22:58:22 2013 VERIFY OK: depth=1, /C=US/ST=CA/L=SanFrancisco/O=Fort-Funst ... ost.domain Wed Mar 13 22:58:22 2013 VERIFY OK: nsCertType=SERVER Wed Mar 13 22:58:22 2013 VERIFY OK: depth=0, /C=US/ST=CA/L=SanFrancisco/O=Fort-Funst ... ost.domain Wed Mar 13 22:58:23 2013 Data Channel Encrypt: Cipher 'BF-CBC' initialized with 128 bit key Wed Mar 13 22:58:23 2013 Data Channel Encrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Wed Mar 13 22:58:23 2013 Data Channel Decrypt: Cipher 'BF-CBC' initialized with 128 bit key Wed Mar 13 22:58:23 2013 Data Channel Decrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Wed Mar 13 22:58:23 2013 Control Channel: TLSv1, cipher TLSv1/SSLv3 DHE-RSA-AES256-SHA, 1024 bit RSA Wed Mar 13 22:58:23 2013 [ec2-server] Peer Connection Initiated with 54.234.43.171:1194 Wed Mar 13 22:58:25 2013 SENT CONTROL [ec2-server]: 'PUSH_REQUEST' (status=1) Wed Mar 13 22:58:25 2013 PUSH: Received control message: 'PUSH_REPLY,route 10.8.0.0 255.255.255.0,topology net30,ping 10,ping-restart 120,ifconfig 10.8.0.6 10.8.0.5' Wed Mar 13 22:58:25 2013 OPTIONS IMPORT: timers and/or timeouts modified Wed Mar 13 22:58:25 2013 OPTIONS IMPORT: --ifconfig/up options modified Wed Mar 13 22:58:25 2013 OPTIONS IMPORT: route options modified Wed Mar 13 22:58:25 2013 ROUTE default_gateway=0.0.0.0 Wed Mar 13 22:58:25 2013 TUN/TAP device /dev/tun0 opened Wed Mar 13 22:58:25 2013 /sbin/ifconfig tun0 delete ifconfig: ioctl (SIOCDIFADDR): Can't assign requested address Wed Mar 13 22:58:25 2013 NOTE: Tried to delete pre-existing tun/tap instance -- No Problem if failure Wed Mar 13 22:58:25 2013 /sbin/ifconfig tun0 10.8.0.6 10.8.0.5 mtu 1500 netmask 255.255.255.255 up Wed Mar 13 22:58:25 2013 /sbin/route add -net 10.8.0.0 10.8.0.5 255.255.255.0 add net 10.8.0.0: gateway 10.8.0.5 Wed Mar 13 22:58:25 2013 Initialization Sequence Completed ^CWed Mar 13 22:58:30 2013 event_wait : Interrupted system call (code=4) Wed Mar 13 22:58:30 2013 TCP/UDP: Closing socket Wed Mar 13 22:58:30 2013 /sbin/route delete -net 10.8.0.0 10.8.0.5 255.255.255.0 delete net 10.8.0.0: gateway 10.8.0.5 Wed Mar 13 22:58:30 2013 Closing TUN/TAP interface Wed Mar 13 22:58:30 2013 SIGINT[hard,] received, process exiting toto5:ttntec2 Dominic$ sudo openvpn2 --config client.conf --remote ec2-54-234-43-171.compute-1.amazonaws.com Wed Mar 13 22:58:57 2013 OpenVPN 2.2.1 x86_64-apple-darwin12.2.0 [SSL] [LZO2] [eurephia] built on Mar 4 2013 Wed Mar 13 22:58:57 2013 NOTE: OpenVPN 2.1 requires '--script-security 2' or higher to call user-defined scripts or executables Wed Mar 13 22:58:57 2013 LZO compression initialized Wed Mar 13 22:58:57 2013 Control Channel MTU parms [ L:1542 D:138 EF:38 EB:0 ET:0 EL:0 ] Wed Mar 13 22:58:57 2013 Socket Buffers: R=[196724->65536] S=[9216->65536] Wed Mar 13 22:58:57 2013 Data Channel MTU parms [ L:1542 D:1450 EF:42 EB:135 ET:0 EL:0 AF:3/1 ] Wed Mar 13 22:58:57 2013 Local Options hash (VER=V4): '41690919' Wed Mar 13 22:58:57 2013 Expected Remote Options hash (VER=V4): '530fdded' Wed Mar 13 22:58:57 2013 UDPv4 link local: [undef] Wed Mar 13 22:58:57 2013 UDPv4 link remote: 54.234.43.171:1194 Wed Mar 13 22:58:57 2013 TLS: Initial packet from 54.234.43.171:1194, sid=a0d75468 ec26de14 Wed Mar 13 22:58:58 2013 VERIFY OK: depth=1, /C=US/ST=CA/L=SanFrancisco/O=Fort-Funst ... ost.domain Wed Mar 13 22:58:58 2013 VERIFY OK: nsCertType=SERVER Wed Mar 13 22:58:58 2013 VERIFY OK: depth=0, /C=US/ST=CA/L=SanFrancisco/O=Fort-Funst ... ost.domain Wed Mar 13 22:58:58 2013 Data Channel Encrypt: Cipher 'BF-CBC' initialized with 128 bit key Wed Mar 13 22:58:58 2013 Data Channel Encrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Wed Mar 13 22:58:58 2013 Data Channel Decrypt: Cipher 'BF-CBC' initialized with 128 bit key Wed Mar 13 22:58:58 2013 Data Channel Decrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Wed Mar 13 22:58:58 2013 Control Channel: TLSv1, cipher TLSv1/SSLv3 DHE-RSA-AES256-SHA, 1024 bit RSA Wed Mar 13 22:58:58 2013 [ec2-server] Peer Connection Initiated with 54.234.43.171:1194 Wed Mar 13 22:59:00 2013 SENT CONTROL [ec2-server]: 'PUSH_REQUEST' (status=1) Wed Mar 13 22:59:00 2013 PUSH: Received control message: 'PUSH_REPLY,redirect-gateway def1 bypass-dhcp,route 10.8.0.0 255.255.255.0,topology net30,ping 10,ping-restart 120,ifconfig 10.8.0.6 10.8.0.5' Wed Mar 13 22:59:00 2013 OPTIONS IMPORT: timers and/or timeouts modified Wed Mar 13 22:59:00 2013 OPTIONS IMPORT: --ifconfig/up options modified Wed Mar 13 22:59:00 2013 OPTIONS IMPORT: route options modified Wed Mar 13 22:59:00 2013 ROUTE default_gateway=0.0.0.0 Wed Mar 13 22:59:00 2013 TUN/TAP device /dev/tun0 opened Wed Mar 13 22:59:00 2013 /sbin/ifconfig tun0 delete ifconfig: ioctl (SIOCDIFADDR): Can't assign requested address Wed Mar 13 22:59:00 2013 NOTE: Tried to delete pre-existing tun/tap instance -- No Problem if failure Wed Mar 13 22:59:00 2013 /sbin/ifconfig tun0 10.8.0.6 10.8.0.5 mtu 1500 netmask 255.255.255.255 up Wed Mar 13 22:59:00 2013 /sbin/route add -net 54.234.43.171 0.0.0.0 255.255.255.255 add net 54.234.43.171: gateway 0.0.0.0 Wed Mar 13 22:59:00 2013 /sbin/route add -net 0.0.0.0 10.8.0.5 128.0.0.0 add net 0.0.0.0: gateway 10.8.0.5 Wed Mar 13 22:59:00 2013 /sbin/route add -net 128.0.0.0 10.8.0.5 128.0.0.0 add net 128.0.0.0: gateway 10.8.0.5 Wed Mar 13 22:59:00 2013 /sbin/route add -net 10.8.0.0 10.8.0.5 255.255.255.0 add net 10.8.0.0: gateway 10.8.0.5 Wed Mar 13 22:59:00 2013 Initialization Sequence Completed Wed Mar 13 22:59:00 2013 write UDPv4: No route to host (code=65) Wed Mar 13 22:59:00 2013 write UDPv4: No route to host (code=65) Wed Mar 13 22:59:01 2013 write UDPv4: No route to host (code=65) Wed Mar 13 22:59:01 2013 write UDPv4: No route to host (code=65) Wed Mar 13 22:59:01 2013 write UDPv4: No route to host (code=65) Wed Mar 13 22:59:02 2013 write UDPv4: No route to host (code=65) Wed Mar 13 22:59:02 2013 write UDPv4: No route to host (code=65) Wed Mar 13 22:59:02 2013 write UDPv4: No route to host (code=65) Wed Mar 13 22:59:02 2013 write UDPv4: No route to host (code=65) Wed Mar 13 22:59:02 2013 write UDPv4: No route to host (code=65) ... The routing table after a connection WITHOUT the push redirect-gateway (all traffic is not redirected to the VPN and everything is working fine, I can ping or ssh the OpenVPN server and access all other Internet resources through my default gateway): Destination Gateway Flags Refs Use Netif Expire default user148-1.wireless UGSc 50 0 en1 10.8/24 10.8.0.5 UGSc 2 7 tun0 10.8.0.5 10.8.0.6 UH 3 2 tun0 127 localhost UCS 0 0 lo0 localhost localhost UH 6 6692 lo0 client.openvpn.net client.openvpn.net UH 3 18 lo0 142.1.148/22 link#5 UCS 2 0 en1 user148-1.wireless 0:90:b:27:10:71 UHLWIir 50 0 en1 76 user150-173.wirele localhost UHS 0 0 lo0 142.1.151.255 ff:ff:ff:ff:ff:ff UHLWbI 0 2 en1 169.254 link#5 UCS 1 0 en1 169.254.255.255 0:90:b:27:10:71 UHLSWi 0 0 en1 71 The routing table after a connection with the push redirect-gateway option enable as in the server.conf file above (all internet traffic should be redirected to the VPN tunnel, but nothing is working, I can't access any Internet ressources at all): Destination Gateway Flags Refs Use Netif Expire 0/1 10.8.0.5 UGSc 1 0 tun0 default user148-1.wireless UGSc 7 0 en1 10.8/24 10.8.0.5 UGSc 0 0 tun0 10.8.0.5 10.8.0.6 UHr 6 0 tun0 54.234.43.171/32 0.0.0.0 UGSc 1 0 en1 127 localhost UCS 0 0 lo0 localhost localhost UH 3 6698 lo0 client.openvpn.net client.openvpn.net UH 0 27 lo0 128.0/1 10.8.0.5 UGSc 2 0 tun0 142.1.148/22 link#5 UCS 1 0 en1 user148-1.wireless 0:90:b:27:10:71 UHLWIir 1 0 en1 833 user150-173.wirele localhost UHS 0 0 lo0 169.254 link#5 UCS 1 0 en1 169.254.255.255 0:90:b:27:10:71 UHLSW 0 0 en1

    Read the article

  • Serious 64-bit laptop

    - by Daniel Gehriger
    For the past couple of years, I have been using an IBM Thinkpad T60p for daily work (software development, desktop & embedded). I am extremely satisfied with this machine, due to its robustness. It also has a few features I depend on: a high resolution display: 15.0" TFT FlexView display with 1600x1200 (UXGA); excellent keyboard; decent graphics and CPU performance. Some of the software I develop benefits from larger amounts of RAM, and 3GB (Windows 7 32-bit) or 4GB (Windows 7 64-bit on T60p) are no longer sufficient. My customers run desktop computers with 20GB and more, and I need to have at least 8GB to at least be able to run reasonable test cases. So I'm shopping around for a new laptop, but I'm struggling to find anything that matches my requirements: must run Windows 7 64-bit Pro or higher; must support at least 8GB of RAM (more is better) high screen resolution! While I prefer 4:3 I can live with wide screen. But I really hope to find something with a vertical screen resolution similar to what I have now... portable, so < 16" but = 14" I realize that FlexView isn't available anymore, but I'd like to avoid a glossy screen if possible. decent (not more) graphics performance, ideally hybrid (I'm doing a lot of CAD, never games). good keyboard reasonable CPU -- but I'm still fine with my current Core 2 Duo, so that shouldn't be too complicated. The T60p fits all those requirements, except the 8GB of RAM. Can you help me find a current notebook that would match most of them? I don't mind changing brand. Thanks!

    Read the article

  • How do I find the cause for a huge difference in performance between two identical Ubuntu servers?

    - by the.duckman
    I am running two Dell R410 servers in the same rack of a data center. Both have the same hardware configuration, run Ubuntu 10.4, have the same packages installed and run the same Java web servers. No other load. One of them is 20-30% faster than the other, very consistently. I used dstat to figure out, if there are more context switches, IO, swapping or anything, but I see no reason for the difference. With the same workload, (no swapping, virtually no IO), the cpu usage and load is higher on one server. So the difference appears to be mainly CPU bound, but while a simple cpu benchmark using sysbench (with all other load turned off) did yield a difference, it was only 6%. So maybe it is not only CPU but also memory performance. I tried to figure out if the BIOS settings differ in some parameter, did a dump using dmidecode, but that yielded no difference. I compared /proc/cpuinfo, no difference. I compared the output of cpufreq-info, no difference. I am lost. What can I do, to figure out, what is going on?

    Read the article

  • How do you apply proxy settings per computer instead of per user?

    - by Oliver Salzburg
    So far, I've used a user group policy object utilizing Internet Explorer maintenance to set a proxy for the user in IE. We have now deployed the Enterprise Client (EC) starter group policy to our domain and this policy affects this behavior. The EC group policy uses the policy Make proxy settings per-machine (rather than per-user). This policy describes itself as: This policy is intended to ensure that proxy settings apply uniformly to the same computer and do not vary from user to user. Great! This seems to be an improvement over my previous setup. If you enable this policy, users cannot set user-specific proxy settings. They must use the zones created for all users of the computer. What zones and where do I configure the proxy settings for them? I assumed the policy would simply take the user settings and apply them, but that's not what's happening. Now no proxy server is set at all. So my previous settings obviously no longer have any effect. So far, I've only come up with solutions that involved direct manipulation of the Windows registry. Which is fine, I guess, but the way the proxy is configured for users makes it appear as if there could be a higher level approach.

    Read the article

  • USB-to-Serial showing gibberish at 115200 Baud

    - by Mose
    I've got a serious problem which drives me crazy because I tried everything I could think of. First of all, I made a video: http://youtu.be/boghkuq7L_s but please read the following text for more information, not only view the video! When using a USB-to-Serial interface everything works as long as I don't go beyond 57600 Baud. At higher rates I only get giberish like this: év.­b0JNLYÆÿ¿iëd0U²(kßÞb! ú]/xscB!ï¯!BoXûÿ1ïâÖCÿ6ÌAnè*íÌC)º¿BíÞØ.C.@ÆÃwHJÂs "YE:ñ.èFðÌCÊ÷ÞÄ !x H w6@BtbHJ ̪ Ì6ì H¾a¿bH.">îvy®;f<ßBÌ p­L¨fæH­E ­þ¼MBÞI What makes the problem so strange is, I exchanged every component and the problem still presists. I tried differtent OSes (Ubuntu, WinXP, Win7, OSX 10.7) with 32 and 64 Bit. I tried USB-to-Serial interface from FTDI and Prolific. I tried reading the output from my Raspberry PI and from an Asterisk Appliance. I changed the cables and the wiring. Nothing helped. In the video I made a example with a old Notebook with native COM and put the USB-to-Serial to the same connection as "sniffer" (only Rx and GND connected) to make sure the output and everything is ok as one can see on the native port. The voltage is ok. Settings for both are 115200 Baud, 8 Bit with 1 Stop and no flow control. Native is ok. USB is messed up. I used the newest drivers and double checked all connections. I have no idea what is wrong here. As I couldn't find anyone describing problems like this I question my long experiance in computer science and think I'm doing some completly wrong... Please help :-/

    Read the article

  • Strange File-Server I/O Spikes - What Is Causing This?

    - by CruftRemover
    I am currently having a problem with a small Linux server that is providing file-sharing services to four Windows 7 32-bit clients. The server is an AMD PhenomX3 with two Western Digital 10EADS (1TB) drives, attached to a Gigabyte GA-MA770T-UD3 mainboard and running Ubuntu Server 10.04.1 LTS. The client machines are taking an extremely long time to access/transfer data on the file server. Applications often become non-responsive while trying to open files located remotely, or one program attempting to open a file but having to wait will prevent other software from accessing network resources at all. Other examples include one image taking 20 seconds or more to open, and in one instance a user waited 110 seconds for Microsoft Word 2007 to save a document. I had initially thought the problem was network-related, but this appears not to be the case. All cables and switches have been tested (one cable was replaced) for verification. This was additionally confirmed when closing down all client machines and rebooting the server resulted in the hard-drive light staying on solid during the startup process. For the first 15 minutes during boot, logon and after logging on (with no client machines attached), the system displayed a load average of 4 or higher. Symptoms included waiting several minutes for the logon prompt to appear, and then several minutes for the password prompt to appear after typing in a user name. After logon, it also took upwards of 45 seconds for the 'smartctl' man page to appear after the command 'man smartctl' was issued. After 15 minutes of this behaviour, the load average dropped to around 0.02 and the machine behaved normally. I have also considered that the problem is hard-drive-related, however diagnostic programs reveal no drive problems. Western Digital DLG, Spinrite and SMARTUDM show no abnormal characteristics - the drives are in perfect health as far as the hardware is concerned. I have thus far been completely unable to track down the cause of this problem, so any help is greatly appreciated. Requested Information: Output of 'free' hxxp://pastebin.com/mfsJS8HS (stupid spam filter) The command 'hdparm -d /dev/sda1' reports: HDIO_GET_DMA failed: Inappropriate ioctl for device (the BIOS is set to AHCI - I probably should have mentioned that).

    Read the article

  • Slow DB Performance. Seems to be memory related.

    - by David
    I am seeing a pooorly performing web app with a SQL 2005 backend. The db is on a w2k3 machine with 4GB RAM. When I run perfmon on it I see the following. Page life expectancy is low. Consistently under 300 while the Buffer cache hit ratio is always 99% +. The target server memory is always 1618304 and the total server memory is always a number just below that. So it seems that it isn't grabbing enough of the available memory. I have AWE enabled, with the lock pages right for the SQL service account and have set a maximum of 2.25Gb... but it doesn't go near that. When I restart the SQL service the page life expectancy goes much higher, 1000+, and the total target memory starts at 0 and slowly works its way back up to the previous limit. Then it hits the limit and the page life expectancy goes back down massively to <300. So I'm guessing there is something limiting the amount of memory. Any ideas on what that would be and how I can fix it?

    Read the article

  • ATI Radeon 5670 Won't Show Resolutions over 1400x900

    - by Phil Sandler
    Just got my new Dell computer with Windows 7 and an ATI Radeon 5670. I attached it to my current monitor, which is a Samsung 24" (2443bwt). Windows 7 does not allow me to display in resolutions greater than 1400 x 900. The setup through a VGA cable into the VGA port of the card. The card also has a DVI port, but I need to use the VGA port because a KVM that supports VGA only. My old PC (which is Windows XP, GeForce 8600 video) can display in 1900 x 1200 on the same monitor (which is what I want) and even higher. It does this through a vga cable also connected to the KVM (through the DVI port but using an adapter). I have tried the same setup (DVI = VGA adapter) on the new PC and nothing changed. I have tried: Updating the drivers via Windows "Update Driver" (says they are current) Installing the updated version of the drivers from ATI (made no difference) Installing Powerstrip (all the options I would need for a custom resolution are greyed out) Installing the drivers/software from ATI caused the ATI Catalyst Control Center software to stop functioning, so I can no longer even start it. I have found some references to other people having this problem and instructions on cleaning the software off and reinstalling it (as uninstalling normally doesn't solve it). I will try this tonight. In any case, I didn't see any options in CCC that would allow me to override the settings for max resolution. However I didn't tinker with it too much before I tried updating the drivers, so I may have missed a setting. I contacted Samsung via online chat and they say it's a problem with the video card/driver (of course--what else would they say?). Any thoughts on what else I could try?

    Read the article

  • LVS / IPVS difference in ActiveConn since upgrading

    - by Hans
    I've recently migrated from an old version of LVS / ldirectord (Ultra Monkey) to a new Debian install with ldirectord. Now the amount of Active Connections is usually higher than the amount of Inactive Connections, it used to be the other way around. Basically on the old load balancer the connections looked something like: -> RemoteAddress:Port Forward Weight ActiveConn InActConn -> 10.84.32.21:0 Masq 1 12 252 -> 10.84.32.22:0 Masq 1 18 368 However since migrating it to the new load balancer it looks more like: -> RemoteAddress:Port Forward Weight ActiveConn InActConn -> 10.84.32.21:0 Masq 1 313 141 -> 10.84.32.22:0 Masq 1 276 183 Old load balancer: Debian 3.1 ipvsadm 1.24 ldirectord 1.2.3 New load balancer: Debian 6.0.5 ipvsadm 1.25 ldirectord 1.0.3 (I guess the versioning system changed) Is it because the old load balancer was running a kernel from 2005, and ldirectord from 2004, and things have simply changed in the past 7 - 8 years? Did I miss some sysctl settings that I should be enforcing for it to behave in the same way? Everything appears to be working fine but can anyone see an issue with this behaviour? Thanks in advance! Additional info: I'm using LVS in masquerading mode, the real servers have the load balancer as their gateway. The real servers are running Apache, which hasn't changed during the upgrade. The boxes themselves show roughly the same amount of Inactive Connections shown in ipvsadm.

    Read the article

  • Matched or unmatched drives for RAID arrays?

    - by Will
    Looking around there is conflciting information on this, with some strongly suggesting one or the other. From my understanding the issue with matched drives is that the wear on both drives is more or less the same, so the potential for the second drive failing with or very soon after the first is pretty high. People also claim matched drives give substianatally higher performance however assuming the unmatched drives are more or less the same (eg 2, 1 TB STATA II 7200rpm drives with 32MB cache), would the minor differences between say a Seagate and a Western Digital one (say one has a 128MB/s read rate, and the other a 150MB/s read rate, as well as I guess various other minor differences) actually cause any notable performance loss, ie potentialy worse than two matched 128MB/s drives, or does RAID not really care and give you essentially an optimal solution (eg upto 278MB/s total read speed for RAID 0 and 1) and similar for other RAID with more "unmatched" drives (5 and 1+0 come to mind as possibilities)? Also I couldnt find much info on how this is different on different RAID setups, eg RAID 0 or RAID 1, software or hardware RAID, etc. I'm assuming such things have an effect, and thats it's not all the same for RAID in general?

    Read the article

  • What are the typical methods used to scale up/out email storage servers?

    - by nareshov
    Hi, What I've tried: I have two email storage architectures. Old and new. Old: courier-imapds on several (18+) 1TB-storage servers. If one of them show signs of running out of disk space, we migrate a few email accounts to another server. the servers don't have replicas. no backups either. New: dovecot2 on a single huge server with 16TB (SATA) storage and a few SSDs we store fresh mails on the SSDs and run a doveadm purge to move mails older than a day to the SATA disks there is an identical server which has a max-15min-old rsync backup from the primary server higher-ups/management wanted to pack in as much storage as possible per server in order to minimise the cost of SSDs per server the rsync'ing is done because GlusterFS wasn't replicating well under that high small/random-IO. scaling out was expected to be done with provisioning another pair of such huge servers on facing disk-crunch issues like in the old architecture, manual moving of email accounts would be done. Concerns/doubts: I'm not convinced with the synchronously-replicated filesystem idea works well for heavy random/small-IO. GlusterFS isn't working for us yet, I'm not sure if there's another filesystem out there for this use case. The idea was to keep identical pairs and use DNS round-robin for email delivery and IMAP/POP3 access. And if one the servers went down for whatever reasons (planned/unplanned), we'd move the IP to the other server in the pair. In filesystems like Lustre, I get the advantage of a single namespace whereby I do not have to worry about manually migrating accounts around and updating MAILHOME paths and other metadata/data. Questions: What are the typical methods used to scale up/out with the traditional software (courier-imapd / dovecot)? Do traditional software that store on a locally mounted filesystem pose a roadblock to scale out with minimal "problems"? Does one have to re-write (parts of) these to work with an object-storage of some sort - such as OpenStack object storage?

    Read the article

  • Problems reviving old pc including graphics card issue.

    - by Mick
    I have a PC that seemed to have died years ago that I am trying to revive. It has a dual core athlon processor and a gigabyte motherboard. It had two dual output graphics cards, and I have long since forgotten which output would print out the diagnostic information as the PC starts up. Also I suspect that the resolution set on all the monitors was probably higher than my current single monitor is capable of displaying. The motherboard also has a built in graphics card, so I thought it may be simplest to remove both the graphics cards and plug my monitor into the onboard graphics just while I get things going. Does that seem sensible? Now the other problem: The PC has two hard drives. I have no idea which one is the primary one it is attempting to boot from. When I power up, the fan comes on and I hear some chuga-chuga-pause chuga-chuga-pause repeat indefinitely. I'm not sure which device is making the noise. There are no-beeps at any time. I see nothing on the screen at any time, not even for a second. Any suggestions? EDIT: If T start up the PC without the power connected to the CDrom there is no chuga-chugan noise.

    Read the article

  • Can’t connect to SQL Server 2008 - looks like Shared Memory problem

    - by Proposition Joe
    I am unable to connect to my local instance of SQL Server 2008 Express using SQL Server Management Studio. I believe the problem is related to a change I made to the connection protocols. Before the error occurred, I had Shared Memory enabled and Named Pipes and TCP/IP disabled. I then enabled both Named Pipes and TCP/IP, and this is when I started experiencing the problem. When I try to connect to the server with SSMS (with either my SQL server sysadmin login or with windows authentication), I get the following error message: A connection was successfully established with the server, but then an error occurred during the login process. (provider: Named Pipes Provider, error: 0 - No process is on the other end of the pipe.) (Microsoft SQL Server, Error: 233) Why is it returning a Named Pipes error? Why would it not just use Shared Memory, as this has a higher priority order in the list of connection protocols? It seems like it is not listening on Shared Memory for some reason? When I set Named Pipes to enabled and try to connect, I get the same error message. My windows account is does not have administrator priviliges on my computer - perhaps this is making a difference in some way (as some of the discussions in this post about an "SuperSocketNetLib\Lpc" registry key seems to suggest). I have tried restarting the SQL Server service, by the way, and also tried to get someone to log onto the machine with an admin account to restart the SQL Server service. Still no luck.

    Read the article

  • Why is piping dd through gzip so much faster than a direct copy?

    - by Foo Bar
    I wanted to backup a path from a computer in my network to another computer in the same network over a 100MBit/s line. For this I did dd if=/local/path of=/remote/path/in/local/network/backup.img which gave me a very low network transfer speed of something about 50 to 100 kB/s, which would have taken forever. So I stopped it and decided to try gzipping it on the fly to make it much smaller so that the amount to transfer is less. So I did dd if=/local/folder | gzip > /remote/path/in/local/network/backup.img.gz But now I get something like 1 MB/s network transfer speed, so a factor of 10 to 20 faster. After noticing this, I tested this on several paths and files and it was always the same. Why does piping dd through gzip also increase the transfer rates by a large factor instead of only reducing the bytelength of the stream by a large factor? I'd expected even a small decrease in transfer rates instead, due to the higher CPU consumption while compressing, but now I get a double plus. Not that I'm not happy, but just wondering. ;)

    Read the article

  • What does the 'Burst Rate' stat mean in HDTune?

    - by UpTheCreek
    I recently upgraded my laptop's v slow hard drive to a seagate momentus 7200. Everything is working fine, but I'm a bit confused by these benchmark results: The burst rate is significantly less than the Maximim transfer rate, and not much higher than the normal minimum (if you ignore the spikes). What's going on here? On the HDtune website it defines Burst Rate as: ...the highest speed (in megabytes per second) at which data can be transferred from the drive interface (IDE or SCSI for example) to the operating system. Which begs some questions... e.g. if this is the highest, then how did the bechmarking tool record the 103MB/sec maximum? And if this really is the true maximum, then where is the bottleneck? The laptops SATA interface is on an Intel 82801GBM southbridge controller. When I check in hardware manager, I see that it's driver is iaStor.sys from 2005. Maybe that's the issue? I'll look for a newever version, but any insights would be appreciated. Thanks

    Read the article

  • Puppet: variable overriding best practices

    - by rvs
    I'm wondering what are best practices for overriding variables in puppet. I'd like to have all my nodes (which located in different places, some of them are qa, some live) with same classes. Now I have something like this: class base_linux { <...> # something which requires $env and $relayhost variables } class linux_live { $relayhost="1.1.1.1" $env = "prod" include base_linux } class linux_qa { $relayhost="2.2.2.2" # override relayhost include base_linux } class linux_trunk { $env = "trunk" # override env inlude linux_qa } node "trunk01" { include linux_trunk include <something else> } node "trunk02" { $relayhost = "3.3.3.3" # override relayhost include linux_trunk include <something else> } node "prod01" { include linux_prod } So, I'd like to have some defaults in base_linux, which can be overrided by linux_qa/linux_live, which can be overrided in higher level classes and node definition. Of course, it does not work (and not expected to work). It does not work with class inheritance as well. Probably, I'll be able to archive using global scope variables, but it does not seems like a good idea to me. What is the best way to solve this problem?

    Read the article

< Previous Page | 229 230 231 232 233 234 235 236 237 238 239 240  | Next Page >