  • Creating virtual switch in VMware

    - by MJI
    We are trying to add a network using vsphere client for VMkernel port while creating a virtual switch. But it prompts us a red cross between the physical adapter and VMkernel port. We did test all the network cables and the network adapters. We tried creating virtual switch for service console but no gains. We have used NIC's which are VMware certified. I have even tried to update bios to check the hardware compatibility but didn't work.

    Read the article

  • How to connect to a Virtualbox guest from the host when network cable unplugged

    - by Greg K
    I'd like to work offline (I'm flying to the US twice this month), to do this I need access to a linux development server. When I work from home I boot a VirtualBox VM and that acts as my dev server for the day (providing Apache, PHP & MySQL to run my server side code). However, I'd like to work with my VM when I'm not connected to a network. I have my Ubuntu VM guest set up with a bridge connection so it can serve HTTP and provide SSH access from inside my local network. I've tried to manually configure my network settings on both Mac OSX (the host) and Ubuntu (the guest) but I can't even ping my own NIC address (127.0.0.1 can, 192.168.21.x I can't) in OS X when I unplug the cable. Manual network settings: $ ifconfig en0 en0: flags=8963<UP,BROADCAST,SMART,RUNNING,PROMISC,SIMPLEX,MULTICAST> mtu 1500 ether 00:xx:xx:xx:xx:xx inet 192.168.21.5 netmask 0xffffff00 broadcast 192.168.21.255 media: autoselect (100baseTX <full-duplex,flow-control>) status: active I can ping localhost fine, as well as my VM (.20) and SSH too. $ ping 192.168.21.5 PING 192.168.21.5 (192.168.21.5): 56 data bytes 64 bytes from 192.168.21.5: icmp_seq=0 ttl=64 time=0.085 ms 64 bytes from 192.168.21.5: icmp_seq=1 ttl=64 time=0.102 ms 64 bytes from 192.168.21.5: icmp_seq=2 ttl=64 time=0.100 ms 64 bytes from 192.168.21.5: icmp_seq=3 ttl=64 time=0.094 ms $ ping 192.168.21.20 PING 192.168.21.20 (192.168.21.20): 56 data bytes 64 bytes from 192.168.21.20: icmp_seq=0 ttl=64 time=0.910 ms 64 bytes from 192.168.21.20: icmp_seq=1 ttl=64 time=1.181 ms 64 bytes from 192.168.21.20: icmp_seq=2 ttl=64 time=1.159 ms 64 bytes from 192.168.21.20: icmp_seq=3 ttl=64 time=1.320 ms Network cable unplugged: $ ifconfig en0 en0: flags=8963<UP,BROADCAST,SMART,RUNNING,PROMISC,SIMPLEX,MULTICAST> mtu 1500 ether 00:xx:xx:xx:xx:xx media: autoselect status: inactive $ ping 192.168.21.5 PING 192.168.21.5 (192.168.21.5): 56 data bytes ping: sendto: No route to host ping: sendto: No route to host Request timeout for icmp_seq 0 ping: sendto: No route to host Request timeout for icmp_seq 1 Does OS X disable the NIC when the network cable is unplugged? Any way to stop it doing this?

    Read the article

  • What does it mean whether network device is Loopback?

    - by Gtker
    Does it mean that the Loopback device handles the request like ping localhost ? If so, there should be at least one device that's loopback,but seems none of my two network device is Loopback: rpcap://\Device\NPF_{45D5ADA0-095E-49F3-BEA1-E8754390F2D4} Description: Network adapter 'Intel(R) PRO/Wireless 2200BG Network Conne ction (Microsoft's Packet Scheduler) ' on local host Loopback: no rpcap://\Device\NPF_{783C5467-4026-473C-86A0-5E5A3708C624} Description: Network adapter 'Realtek RTL8169/8110 Family Gigabit Ethern et NIC (Microsoft's Packet Scheduler) ' on local host Loopback: no Can someone clarify all this?

    Read the article

  • TCP/IP & throughput between FreeNAS (BSD) server & other LAN machines

    - by Tim Dickerson
    I have got a question for someone that knows BSD a bit better than me that are in regards to my LAN setup at home/work here outside Chicago. I can't seem to fully optimize my network's (LAN) thoughput via my FreeNAS (BSD based) file server. It runs with the latest FreeBSD release which is modified to support several protocols for file transfers and more. Every machine that is behind my Smoothwall (Linux based) router is on the usual 192.168.0.x subnet and for most part works just fine. Behind the Smoothwall box, all machines are connected to a GB HP unmanaged switch. I host a large WISP here and have an OC-3 connection here at home/work and have no issues with downloading/uploading from/to the 'net'. My problem is with throughput. When I try and transfer large files...really any for that matter..between any of the machines to/and from the FreeNAS server via FTP, the max throughput I can achieve say between a Win 7 or a Linux box is ~65Mbit/sec. All machines are running Intel Pro 1000 GB NIC's and all cable is CAT6. Each is set to 'auto negotiation' and each shows 1500 MTU Full Duplex @1GB so I know the hardware is okay. I have not adjusted the MTU on any machine as I understand it to be pointless unless certain configurations are used (I assume I am not one of those). My settings for the FreeNAS machine are the following: # FreeNAS /etc/sysctl.conf - pertinent settings shown kern.ipc.maxsockbuf=262144 kern.ipc.nmbclusters=32768 kern.ipc.somaxconn=8192 kern.maxfiles=65536 kern.maxfilesperproc=32768 net.inet.tcp.delayed_ack=0 net.inet.tcp.inflight.enable=0 net.inet.tcp.path_mtu_discovery=0 net.inet.tcp.recvbuf_auto=1 net.inet.tcp.recvbuf_inc=524288 net.inet.tcp.recvbuf_max=16777216 net.inet.tcp.recvspace=65536 net.inet.tcp.rfc1323=1 net.inet.tcp.sendbuf_inc=16384 net.inet.tcp.sendbuf_max=16777216 net.inet.tcp.sendspace=65536 net.inet.udp.recvspace=65536 net.local.stream.recvspace=65536 net.local.stream.sendspace=65536 net.inet.tcp.hostcache.expire=1 From what I can tell, that looks to be a somewhat optimized profile for a typical BSD machine acting as a server for a LAN. I might be wrong and just wanted to find out from someone that knows BSD better than I do if indeed that is ok or if something is out of tune or what. Are there other ways I would find better for P2P file transfers? I honestly do not know what I SHOULD be looking for with respect to throughput between the NAS box and another client when xferring files via FTP, but I am told that what I get on average (40-70MB/sec) is too low for what it could be. I have thought about adding another NIC in the FreeNAS box as well as the Win7 machine and use a X-over cable via a static route, but wanted to check with someone first to see if that might be worth it or not. I don't know if doing that would bypass the HP GB switch and allow for a machine to machine xfer anyways. The FTP client I use is: Filezilla and have tried both active and passive modes with no real gain over each other. The NAS box runs ProFTPD.

    Read the article

  • Fiber optic internet, final connection to lan

    - by RayQuang
    Hi, We have fiber optic internet coming to our office soon, and i would like to know if it would be worth installing fiber NIC's in our servers and machines instead of using cat6 gigabit. Here is the layout: (fiber) cable from distribution point in basement - fiber optic modem - Network gateway (debian lenny) - network computers and servers I was wondering if it would be worth installing a fiber connection from the modem to the gateway and the network clients. Will the costs be worth it in terms of speed, latency and stability? Thanks, RayQuang

    Read the article

  • monitor internet bandwidth

    - by enriquev
    Hello, I'm looking for a windows tool that can tell me who is using bandwith. As of now I've setup so that the switch where all pcs are connected, mirrors the router's traffic to my pc, meaning that from my NIC I am able to see all outgoing and incoming internet connections. This works, I have used NIMAS (http://www.vmware.com/appliances/directory/200) and I am able to see internet traffic. Now what I am looking for is something even more simple, where I can see what computers are using what banwidth, live.

    Read the article

  • Multihomed Windows server and DNS resolution

    - by mpkilroy
    I have a Windows 2008 server with two IP addresses assigned to a single NIC. The DNS settings are setup to register the connections's addresses on the DNS server. nslookup shows both IP addresses for the server name. How is name resolution done in this case, i.e. which IP address does the DNS server return for a host lookup? Or does it return both, and the client selects one of the addresses?

    Read the article

  • Ubuntu with KVM guest VM and broken bridges

    - by MadPsy
    I have an Ubuntu box with a KVM guest VM running. They use bridging so the guest VM attaches to the physical network of its host. The guest VM has 2 NICs in 2 different bridges. First NIC of the VM is tap5 and is in bridge br0 br0 8000.46720f5c572e no eth0.500 tap5 Second NIC of the VM is tap2 and is in bridge br100 br100 8000.76ad2fc96661 no eth0.100 eth0.101 eth0.103 eth0.104 eth0.105 tap2 On the host, br0 has an IP and br100 does not 21: br0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP link/ether 46:72:0f:5c:57:2e brd ff:ff:ff:ff:ff:ff inet 192.168.100.4/24 brd 192.168.10.255 scope global br0 inet6 fe80::d6ae:52ff:febe:777/64 scope link valid_lft forever preferred_lft forever On the guest, its eth0 and eth1 interfaces both have IP addresses 2: eth0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast state UP qlen 1000 link/ether 00:3e:61:fb:7a:da brd ff:ff:ff:ff:ff:ff inet 192.168.100.6/24 brd 192.168.100.255 scope global eth0 inet6 fe80::23e:61ff:fefb:7ada/64 scope link valid_lft forever preferred_lft forever 3: eth1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast state UP qlen 1000 link/ether 00:3e:61:fb:7a:ea brd ff:ff:ff:ff:ff:ff inet 172.16.50.129/25 brd 172.16.50.255 scope global eth1 inet6 fe80::23e:61ff:fefb:7aea/64 scope link valid_lft forever preferred_lft forever On the guest VM, a tcpdump of its eth1 interface (tap2) shows traffic from its eth0 interface (tap5), as if the 2 bridges are themselves bridged. This means any interface on br100 is now bridged across to br0 - which is completely broken. root@chillispot:~# tcpdump -c 1 -n -v -i eth1 net 192.168.100.0/24 tcpdump: listening on eth1, link-type EN10MB (Ethernet), capture size 65535 bytes 16:31:24.175583 IP (tos 0x0, ttl 64, id 48054, offset 0, flags [DF], proto TCP (6), length 148) 192.168.100.6.22 > 192.168.100.4.59505: Flags [P.], cksum 0x6c2b (correct), seq 1056321648:1056321744, ack 398642983, win 1700, options [nop,nop,TS val 197473436 ecr 200655363], length 96 What could be bridging the 2 bridges, except the guest VM (which is a stock Ubuntu install)? I am at a complete loss! Thanks.

    Read the article

  • No Connectivity to ESX guests on one server

    - by Sam Cogan
    I have a number of ESX servers hosting VM's, all but one of these works ok, however one server has a problem where any guests on not contactable over the network. The ESX hosts is contactable, is integrated int VCenter, and you can even live migrate VM's to and from this server, but any VM's on that server are unable to talk to the rest of the network. The VM's NIC is shown as Up and has the right IP configuration, and as soon as you move it back to another host it works fine.

    Read the article

  • Two wireless NICs on a MacBook - can I bind all VPN traffic to one, and everything else to another?

    - by Ben Aston
    I frequently connect to my workplace over a VPN. I would like to continue watching videos from, say YouTube, whilst I work on the VPN, without degrading the available VPN bandwidth (say for an RDP session). Can I configure a second NIC to deal with only the VPN traffic, with everything else going over the primary? Specs as requested: Macbook Pro, OSX Snow Leopard, using the built in OSX VPN connectivity, the in-built airport card and a USB external wifi adapter.

    Read the article

  • Two DHCP bindings

    - by VoVA
    Dear friends ! Please help me resolve very stupid question: Here is situation: OS: 2008 R2, DHCP service, 2 NICs So, the main goal is to make two scope on DHCP service, each of scope will link to each of NIC. Any ideas ? O_o Thanks ! PS Don't ask to reinstall onto Linux,FreeBSD :)

    Read the article

  • hyperv machine guest loads slow

    - by Dani Avni
    this is by far one of the strangest things I have seen. I have a win 2008R2 cluster with a CSV. the CSV itself is on an iSCSI storage (hitachi HUS 110) basic config of the two hosts in the cluster is Dell R610 Win 2008 R2 with all patches 64GB 1 NIC for host access 2 NICs for guest access 2 NICs for iSCSI these machine work great and I can load a 2008R2 test guest machine on them in less than 90 seconds after the above config is running for over a year, I now need to add a new host. now the host is Dell R620 (Still intel but different CPU) Win 2008 R2 with all patches 64GB 1 NIC for host access 2 NICs for guest access 2 NICs for iSCSI I added this new host to the domain and to the cluster, I gave it access to the CSV and I tried loading the same guest machine that loads in 90 seconds in the other hosts. the machine loads in about 6 minutes. no matter how many times I try this the old hosts load the machine in about 90 seconds and this new host in around 6 minutes to eliminate any problems with the iSCSI connection, I added a new LUN and directly accessed it from the new host and I was working at around 300MB/s so no problem there. I also tested the connection between the other hosts and the new one and network is working fine there too. to eliminate problems in HyperV, I copied the machine to the local disk of the new host and it loaded in less than 20 seconds. now is the point were things get a lot stranger: in my tests I tried installing a fresh windows guest machine to the CSV from the new host. I noticed that while the fresh windows was installing, my test guest was loading in less than 90 seconds even on the new host (I repeated this a few times). If I paused the fresh install guest and tried loading the test guest again it loaded in 6 minutes. and again after I resumed the guest installation the test guest loaded fast. after the fresh windows was also loaded, I ran tests loading the fresh window and my test machine. each one of them loaded in about 5 minutes when I tried loading them separately. however when I started both of them in the same time they both loaded in around 2.5 minutes it seems that the iSCSI disk access is only working if it is under some load (although I never got to above 10% utilization according to the task manager) does anyone have any idea what could be the problem?

    Read the article

  • Network Interface Lost Functionality after Firewall Installation Hung

    - by Sadeq Dousti
    I tried to install Agnitum Outpost firewall, but the setup hung while installing network drivers. Oddly, the NIC properties shows no connect string whatsoever, nor any services: http://pic-ups.com/images/1fjf.png Device Manager shows problematic drivers as well: www.pic-ups.com/images/2aqa.png Any suggestions? PS: I'm using Windows XP SP3. PS2: I applied instructions below, but all were in vein: www.agnitum.com/support/kb/article.php?id=1000041 www.agnitum.com/support/kb/article.php?id=1000159

    Read the article

  • what virtual machine should dell poweredg sc 1425 install?

    - by Nguyen Khanh Huy
    I'm intalling our local server and want to install a virtual machine but it seem vmware ESXi is not suit with our server Server: Dell SC 1424 CPU : 2 Xeon 3.2G (buss 800, cache L2 2M) Ram: 6G DDR ECC 266 Hard disk: 2 Hitachi Sata 1TB. Raid Dell Cerc 2s ( raid 0, 1) Nic: 2 Broadcom 1Gb/s I'm wondering if you're familiar with this area and have any idea about a VM software for our server. Just wanted to use server for some purposes ( web hosting, subversion and to experience some server OSs) Thank you for helping.

    Read the article

  • Windows SMTP Server Outbound IP

    - by Josh
    I have a Windows 2008 server that has three IP bound to the NIC. I can select which IP Windows SMTP listens to, but I want to also set the IP address used when mail is sent. Where would I set which IP to use when sending email?

    Read the article

  • Squid on windows loadbalancing only to one server

    - by Martin L.
    After thousands of googles and trying days i cant get the load balancer/failover in squid on windows to work. Iam using squid 2.7. My webservers are 2 single NIC lighttpd and one dual nic lighttpd. server1 in this example is running squid on port 80 and lighttpd on port 8080 (just to test) Requirements: All 3 webservers running lighttpd should be balanced two option for load balancing: Best would be if server1 is busy server2 takes over, if server2 is busy server3 takes over, etc.. Round robin style evenly distributed load. Eg server1 takes first call, server2 second etc.. All requests should be treated the same way (no url rewriting or so on) Sent host headers have to be redirected to every server as http host header, speaking of "server1", "server1.company.internal" and "10.211.1.1". My approach: acl all src all acl manager proto cache_object http_port 80 accel defaultsite=server1.company.internal vhost #reverse proxy entries cache_peer 10.211.2.1 parent 8080 0 no-query originserver round-robin login=PASS name=server1_nic1 cache_peer 10.211.1.2 parent 80 0 no-query originserver round-robin login=PASS name=server2_nic1 cache_peer 10.211.2.3 parent 8080 0 no-query originserver round-robin login=PASS name=server3_nic1 cache_peer 10.211.2.4 parent 8080 0 no-query originserver round-robin login=PASS name=server3_nic2 #decl of names of squid host acl registered_name_hostdomain dstdomain server1.company.internal acl registered_name_host dstdomain server1 #ip of squid host acl registered_name_ip dstdomain 10.211.2.1 # access: redirects the correct squid hostname http_access allow registered_name_hostdomain http_access allow registered_name_host http_access allow registered_name_ip http_access deny all cache_peer_access server1_nic1 allow registered_name_hostdomain cache_peer_access server1_nic1 allow registered_name_host cache_peer_access server1_nic1 allow registered_name_ip cache_peer_access server2_nic1 allow registered_name_hostdomain cache_peer_access server2_nic1 allow registered_name_host cache_peer_access server2_nic1 allow registered_name_ip cache_peer_access server3_nic1 allow registered_name_hostdomain cache_peer_access server3_nic1 allow registered_name_host cache_peer_access server3_nic1 allow registered_name_ip cache_peer_access server3_nic2 allow registered_name_hostdomain cache_peer_access server3_nic2 allow registered_name_host cache_peer_access server3_nic2 allow registered_name_ip cache_peer_access server1_nic1 deny all cache_peer_access server2_nic1 deny all cache_peer_access server3_nic1 deny all cache_peer_access server3_nic2 deny all never_direct allow all Problems: Load balancer does not load balance other than to first server. Only if the first server is killed in any way the second will take over. I have seen the others working at some point, but definitely not as the intended load balancing described above. If the cache_peer_access is not defined sometimes the wrong hostname is sent to the backend webserver and this always depends on the defaultsite= parameter. Probably because the host header on the request to squid is not set and its replaced by defaultsite. Leaving out defaultsite didnt solve the problem. The only workaround i found for this is the current approach with cache_peer_access. Questions: Does the cache_peer_access influence the round-robin? Is there a better workaround to pass the host header to the backed webservers? Which parameters do increase the speed of load balancing or does anyone have a better approach? -Martin

    Read the article

  • Cannot increase MTU on gigabit network

    - by RayQuang
    Hi, I have just set up my new gigabit network and when I was about to increase the MTU to use jumbo frames, I get this error: root@rayquang-desktop:~# ifconfig eth1 mtu 9000 SIOCSIFMTU: Invalid argument Could anyone help me to increase the MTU. Details: NIC: NETGEAR GA311; Switch: NETGEAR GS105, running Ubuntu 10.10 and Debian Lenny on desktop, server respectively. Help would be greatly appreciated, RayQuang

    Read the article

  • iptables intercept local traffic

    - by Anonymous
    i hope someone can help me out with somewhat simple task. I'm trying to redirect a client in my router through my desktop PC, so i can dump the traffic and analyze it (its potential source of poisoning the network with malicious packets). However i don't have a second NIC on my hands and i was hoping i can redirect all the traffic from that IP through my PC. In essence to become MITM for the client. Does anyone have any idea where to start: Current state: (localip)-(router)-(internet) And what i want to do: (localip)-(pc)-(router)-(internet)

    Read the article

  • Could not load drivers - Code 31

    - by alexander7567
    I get this error when installing any network adapter on my computer: The device is not working properly because Windows cannot load the drivers required for this device. (Code 31) I have tried many different adapters and many different drivers. Any ideas? OS: Windows XP Home SP3 Here is the Hardware IDs for the onboard NIC: PCI\VEN_8086&DEV_1050&SUBSYS_2019107B&REV_02 PCI\VEN_8086&DEV_1050&SUBSYS_2019107B PCI\VEN_8086&DEV_1050&CC_020000 PCI\VEN_8086&DEV_1050&CC_0200 Device Manager Screenshot

    Read the article

  • Server 2012 intermittently fails to respond to pings from single host, even with firewall disabled, but responds to non-ICMP requests fine

    - by James Westbury
    This one is kind of weird. I've got the following machines involved: DC01 - 10.1.2.42, Server 2012, domain controller & DNS server, physical machine nagiosv - 10.1.2.35, CentOS 6.4, Nagios, virtual machine CB01 - 10.1.3.81, Ubuntu 12.04 LTS, couchbase server, virtual machine So, I noticed something was wrong while configuring this new Nagios VM. I started seeing DC01's state flapping. I logged into nagiosv when I saw this happening, and attempted to ping DC01, both by FQDN and its IP address. Neither worked. I tried pinging the machine from CB01, which is another VM on the same virtual switch/physical NIC as nagiosv, and that worked fine. Pings still failing from nagiosv at this time. DC01 is also an internal DNS server, so I ran dig google.com from nagiosv, and was able to run a query against DC01 just fine: ;; Query time: 1 msec ;; SERVER: 10.1.2.42#53(10.1.2.42) ;; WHEN: Fri Nov 1 07:53:51 2013 ;; MSG SIZE rcvd: 204 Pings still failing from nagiosv, though. I can ping from DC01 to nagiosv, and that works, and I can still ping from other VMs on the same physical NIC into DC01, and that works. I should mention at this point that I've disabled the firewall on DC01 for testing purposes, and it doesn't make a damned bit of difference. (Even with the firewall enabled, I have a blanket exception for ICMP from the local subnet, so it shouldn't make a difference, but I figured I should test it anyway.) I loaded up Wireshark on DC01 and pinged it from nagiosv again. What I see is a bunch of echo requests coming in and not a single reply going back out. Filtered results here, showing all ICMP traffic during a 15-second period. A few more bits of info: There are no IP conflicts on the network. MAC addresses on the incoming pings match the MAC on the VM. There are no duplicate MACs on the network, as far as I can see. I have absolutely no idea why DC01 is failing to respond, here. Any ideas?

    Read the article

  • What is the probable failure - no BSOD, no event log, monitors sleeping, force reboot required

    - by Tyler
    Every 3 to 15 days, my PC freezes. This typically happens when the computer is idle, I'm coming home from work, back from vacation, etc. It's never happened while using my computer. The monitors are in power save mode The Caps Lock light on the (wireless) keyboard doesn't work Ctrl-alt-del has no effect, mouse (wireless) has no effect The hardware reset button and single press of power putton have no effect Computer does not appear on the network No BSOD, no memory dump Event logs have no errors or indications of problems near the time of crash. Only messages after reboot indicating that there was a reboot without a clean shutdown. Windows is set to never put the computer to sleep (just the display) Here are the vital stats of the build: OS Windows 8 Pro 64-bit CPU Intel i5-2400 Mobo Intel BOXDP67DE Micro ATX GPU MSI N460GTX Cyclone768D5/OC RAM CORSAIR XMS3 8GB (2 x 4GB) CMX8GX3M2A1333C9 PSU SeaSonic X Series X650 Gold System Drive Samsung 840 Pro 256 GB SSD Data Drive 2 x Western Digital WD20EARS 2TB in hardware RAID 1 Optical Lite-On DVD burner IHAS424-98 And here is the story of how the problem developed and what I've done to diagnose: January 2011, system built with Windows 7 64-bit, runs great. March 2011, Intel replaced the mobo because of the bad sata controllers. October 2012, upgrade to Windows 8 (problems start shortly after). January 2013, system freezes and causes network to fail for the whole house. Unplug the network cable and other devices and PCs can use the internet. Plug it back in, internet goes away for everyone. Reboot and everything is fine. March 2013, install Intel Gigabit CT PCI-E NIC, disable mobo nic in bios. Network strangeness goes away. Freezes are less frequent. Memtest shows no problems (20 passes). Early June 2013, replace Antec PSU with SeaSonic PSU. Mid June 2013, replace OCZ Vertex 2 SSD with Samsung SSD. Late June 2013, get frustrated and hope the community has some good ideas (I'm running out of budget to replace parts). My next plan of attack is setting "Turn off display" to Never and using a screen saver to see how that reacts on the next freeze. It makes me sad to waste power for up to 15 days though. Has anyone out there seen a problem like this? Any ideas on what kind of malfunction would act this way? Ideas of other diagnostic steps to take?